1. When a single air conditioner creates the perfect coolness Imagination Lives
Experience this year’s Ceiling
air conditioners, with the style
and the functionality.
CAC
2009
SAMSUNG
System Air Conditioner
2. Perfect fit for every space
A perfect air conditioner is different, it depends on the application and end user. Each building and
space has different objectives and different people inside. Perfect fit, Samsung Commercial Air
Conditioners were designed as if it was customized to fit in to your interior design. Slim and
compact, with aerodynamically designed parts will deliver the cool air with style.
SAMSUNG ELECTRONICS HOME APPLIANCE
PRODUCT AWARDS
Technology can contribute to the development of a greener, cleaner world and
increase quality of life. This is a philosophy we have held at Samsung for over 30
years. Ever since its establishment in 1973, Samsung Electronics has
concentrated on developing environmentally friendly products and has converged
increasingly sophisticated digital technology with its appliance products to attain a
strong technological advantage in improving consumers' quality of living with the
ultimate in convenience and style.
3. Big Confidence Global Leading
Company >> SAMSUNG
Since day one, Samsung Electronics has committed itself to becoming a leader in every facet of its market
initiatives. The result is the growth of a brand that’s synonymous with impeccable standards, high quality products,
and an unwavering dedication to the customer. Through continuous creativity and the development of highly
innovative products, Samsung has captured the hearts and minds of customers worldwide, which will propel our
company and our brand well into the future.
SAMSUNG’S BRAND VALUE
In the Digital era, products are being distinguished by their
brand in addition to their functions or quality. In 1999 Samsung
Electronics has implemented its global brand communication
strategy. Since then, based on the research conducted by
Interbrand INC., USA, Samsung Electronics has become one of
the fastest growing brands equities from 6.4 billion USD (2001)
to over 17.7 billion USD (2008) and is now ranked 21st on
Interbrand's Top100 Global Brand List.
Samsung has increased its value by emphasizing technology as
a life innovator. Samsung will remain close to the customer
through its technologies contributing to a higher quality of life.
GLOBAL BUSINESS NETWORK
Samsung's thrust on Product Innovation and R&D has given the company a competitive edge in the marketplace. With an
investment of over USD 4.59 billion, Samsung operates 16 R&D centers worldwide and employs 27,000 researchers of which
2,500 hold a Ph. D. As a result, Samsung has already applied for 1600 patents in the USA. The focus of the R&D center is to
customize electronics products to meet the Specific needs of consumers in that region. Samsung R&D Centers are helping the
company to continuously innovate and introduce products customized for today’s global market.
6 Global Operation Centers
10 Global Headquarters
Europe
Stuttgart
CIS
Milano
ME Asia Africa
India
SW Asia
SE Asia
Delhi
China
Korea
Shanghai
Japan Los Angeles
Mexico
US Chicago
Latin America
Malaysia
Thailand
London
7 Design Centers
5 HA R&D Centers
2009 SAMSUNG Ceiling Air Conditioner
02 | INTRODUCTION 09 | Line-up 12 | S-Inverter
Technology
14 | Indoor Units 52 | Control Systems
4. Four Seasons of Hope
Samsung's Four Seasons of Hope is about kids. It's about using the power of our brand to give something back to the
communities we serve.
Samsung's Four Seasons of Hope supports community-based foundations and charities headed by some of this country's
favorite sports legends. Samsung pledges to raise national awareness and funds for these outstanding charities and to
identify how others can also make a difference in the lives of these children and families.
Samsung Recycling DirectSM
All good things come to an end. Let's make sure it's a Green end.
As technology continually evolves, so will your digital lifestyle. When you upgrade your consumer electronics, you will need
to recycle your old products responsibly. That's why we're proud to reaffirm our commitment and responsibility to recycle
DirectSM
using the new Samsung Recycling program launched on October 1st, 2008.
Thinking of You.
Making industry-leading products is only part of the big picture. Our commitment to creating a better world for future
generations is equally as important. We strongly believe that if future generations aren't given the
opportunity to succeed, we definitely won't. As a corporate citizen, we have dedicated ourselves to nurturing our
local communities through corporate social responsibility and co-prosperity initiatives. Samsung has also remained
steadfast when it comes to supporting education initiatives, helping to preserve the "greening" of the planet where
you live.
"A global leader is not only responsible for that which lies within its walls but also
for that which lies beyond them."
Reported by Greenpeace
Samsung comes in second place with 5.7, scoring well on
chemicals and waste criteria. Samsung's score on e-waste is
helped by getting top marks for reporting recycling rates of
137% for TVs (based on past sales 10 years ago, the average
life span, since when Samsung's TV sales have increased
10-fold), 12% for PCs (based on 7 year lifespan) and 9%
for mobile phones (based on 2 year lifespan). It also scores well
on its use of recycled plastic, which is 16.1%, though only 0.2%
is post-consumer plastic, with a goal to increase to 25% by 2008.
Nokia:Clear leader after improving take-back in
India.
SAMSUNG / Good scores on chemicals
and e-waste criteria.
Fujitsu Siemens:New deadline for removal of
BFRs and PVC but still poor on recycling.
Sony Ericsson:Good on toxic chemicals and
energy but very poor on recycling.
Sony:Good on toxic chemicals, room for
improvement on energy.
LG:Improved score on recycling and energy.
Toshiba:Improved climate policy, but poor on
recycling.
Dell:Dropping down with poor scores on
climate policy.
HP:Slightly improved score but no products
free of most toxic chemicals.
Acer:Good on chemicals policy but poor on
energy policy.
Panasonic:Needs to improve recycling and
amount of renewable energy.
Philips:Worst company on recycling with
additional penalty for negative lobbying in Europe.
Apple:Progress on eliminating toxics from new
products but needs to improve on recycling and
energy.
Lenovo:New US tack back scheme, but still no
products free of worst toxic chemicals.
Motorola:Only phone company not to set a
timeline for eliminating worst toxic chemicals.
Sharp:Most points on toxic chemicals, poor on
recycling and energy.
Microsoft:Very poor on recycling and energy.
Nintendo:Zero on most criteria except chemicals
management and energy.
[Standard for the second quarter, 2008]
7
5.7
5.5
5.3
5.3
4.9
4.7
4.7
4.7
4.5
4.5
4.3
4.1
4.1
3.7
3.1
2.2
0.8
Eco-labels & Declaration
Samsung Electronics makes an effort to develop environment-
friendly products that minimize the negative impacts on the
environment in every aspect of its products, from raw material
procurement, production, transportation, usage, and final
disposal. Concerns for the environment are at the core of each
product development.
Samsung's environment-friendly technologies and recycling
programs have received global approval, receiving well-known
awards and recognitions worldwide.
Samsung eco mark Energy mark Korea Eco Mark Korea
Ecoflower EU Energy Star Mark TCO Sweden
Blue Angel Germany EPEAT US Eco Mark Korea 2
5. Type 9K Btu/h
2.6 kW
12K Btu/h
3.5 kW
18K Btu/h
5.2 kW
21K Btu/h
6.0 kW
24K Btu/h
7.0 kW
30K Btu/h
9.0 kW
36K Btu/h
10.5 kW
48K Btu/h
14.0 kW
Non-inverter
S-Inverter
R-Inverter
1Phase
1Phase
3Phase
1Phase
3Phase
Technology
Capacity
R410A
2009 Product Line-up This year’s product line-up still supports a wide range of
choices, all of them equipped with Samsung’s advanced
technology.
OUTDOOR UNITS
08
092009 Samsung Ceiling Air Conditioners
'Eco-friendly'- Samsung
Preserves the nature you live in.
Thinking of you and the environment, Samsung plans for the future. Realizing your hopes for a greener, healthier
life for you and the generations that follow, Samsung's environmentally friendly technologies work to make the
world a more beautiful place.
Air & Water Conservation
As a leading innovator of environment-friendly products and technologies, Samsung products already
drastically reduce the strains on nature's valuable resources. Samsung uses R-600, a natural refrigerant, and
cyclopentane insulation in its refrigerators, which do not promote global warming and does not add to the
greenhouse effect. Samsung's water-efficient washing machines also use less detergent and water without
affecting cleanliness, helping to conserve water.
Use Less, Save More
Samsung products are energy efficient, receiving Energy Grade A+ in the EU and ENERGY STAR in the U.S.
Samsung washers with its ceramic heaters use less power, which saves you energy, money, and time. This
energy-efficient technology protects you and nature, giving you a greener lifestyle.
Global Recycling
Samsung Electronics is making significant efforts to save the environment and complies with the WEEE
(Waste Electrical and Electronic Equipment) directive by joining or establishing the recycling schemes for each
country.
Samsung Eco-Friendly System Air Conditioner
Making continuous efforts to stay eco-friendly, Samsung's air
condition-ers use R-410A, an environmentally friendly refrigerant to
help rid the air of pollutants and restrain the use of materials with high
global warming potential (GWP). Most Samsung products have
received Energy Grade A+ in the EU and ENERGY STAR in the U.S.
These energy-efficient air conditioners not only save you money, but
help conserve the environment.
6. 2009 Product Line-up
INDOOR UNITS
This year’s product line-up still supports a wide range
of choices, all of them equipped with Samsung’s
advanced technology.
R410A
9K Btu/h
2.6 kW
12K Btu/h
3.5 kW
18K Btu/h
5.2 kW
24K Btu/h
7.0 kW
30K Btu/h
9.0 kW
36K Btu/h
10.5 kW
48K Btu/h
14.0 kW
21K Btu/h
6.0 kWTechnologyType Capacity
10
112009 Samsung Ceiling Air Conditioners
1Way cassette
4Way cassette
Ceiling
Slim Duct
MSP Duct
Mini 4Way cassette
Console
2Way cassette
Inverter
Inverter
R-Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
R - Inverter
Non-inverter
Non-inverter
Non-inverter
Non-inverter
Non-inverter
7. 12
132009 Samsung Ceiling Air Conditioners
25 C
24 C
23 C
25 26 27 28 29 30 31 10 12 14 16 18 20 22 24 26
27'21"
31'24"
17'41"
27'23"
Faster Faster
Fast Cooling and Heating
When you change the temperature setting, the air
conditioner will use the compressor's maximum
capacity to quickly reach the desired temperature,
resulting in 15% faster cooling and 50% faster heating.
Comfortable Temperature
The S-Inverter Air Conditioner works at maximum
capacity at start up. As soon as the temperature
reaches the desired set temperature, it finely adjusts
to cope with any changes. This means less temperature
fluctuation and assures you greater comfort that can
be achieved in minutes.
High Efficiency
The S-Inverter technology gives you powerful, speedy
cooling and heating at minimum electricity consumption,
so you can reduce energy waste and save money.
Up to 50% Energy Saving
After reaching the set temperature, the S-Inverter Air
Conditioner changes its operation mode to economic.
By avoiding inefficient and frequent switching on and
off of the compressor, the S-Inverter saves up to 50%
in energy consumption compared with a non-inverter
air conditioner.
200 300 400 500 600
302Wh/h
621.4Wh/h
Saving
Silent Operation
Enjoy peace and quiet. The air conditioner's
compressor operates at the lowest speed possible to
maintain the desired temperature, so there's less
motor and fan noise.
20dB 25 30
27dB Silent
Wide Temperature Performance
No need to worry about using an external unit in
severe temperatures with a Samsung air conditioner.
With a wider temperature allowance, the unit can cool
in the burning heat of 50°C or heat in the freezing
coldness of -20°C to provide comfort in your home. -10 0 10
Wider operation Range
20 30 40 -20 -10 0 10 20 30
-10o
C ~ 15o
C
-20o
C ~ 24o
C
Wider operation Range
Comfortable
S-Inverter
Steady Temperature Fluctuation
Non Inverter
High Temperature Fluctuation
Uncomfortable
(Energy Loss)
Uncomfortable
(Energy Loss)
In reducing electricity costs for an air conditioner, an inverter is a must. Samsung’s S-Inverter
technology lowers energy consumption by up to 50% compared to a conventional air conditioner.
Its powerful and delicate control lets you reach the desired temperature quickly and maintains
precise temperatures so there’s less fluctuation and less motor run-time, which means quieter
operating noise and less energy waste.
Strong and Quiet S-Inverter
8. INDOOR UNITS
01
14
152009 Samsung Ceiling Air Conditioners
Cold air, delivered evenly to
every corner of your space
Indoor units made just for you! Samsung’s indoor units have their own individual
unique features for the perfect air throughout the entire space. Indoor units
designed to fit all the different types of space. It will make you feel like owning
your own customized air conditioner just for you.
18
22
28
30
| Slim 1Way Cassette
| 4Way Cassette
| Mini 4Way Cassette
| 2Way Cassette
| Cassette Type
34
36
| Slim Duct
| MSP Duct
| Duct Type
44
48
| Console
| Ceiling
| Floor & Convertible Type
9. Wide Blade
The new cassette type air conditioner is equipped with uniquely designed blades that are wider to provide even
cooling and heating power throughout the room.
WIDEWIDEWIDEWIDE
64mm
46mm
WIDER
Airflow is directed towards the
ceiling which cause ceiling
soiling.
Airflow is directed downwards
without having contact with the
ceiling.
Ceiling Soiling Prevention
Newly designed panel will control the air direction to avoid
having contact with the ceiling. This new design will prevent
the ceiling soiling and keep your interior cleaner than ever
even, after long period of operation.
Conventional Blade
Ceiling Ceiling
New Blade
600(mm) 650
Lift-up Range
700 750
750mm
700mm
High Lift-up Drain Pump
The lift-up drain pump lifts condensed water up to 750mm,
compared to the competitor’s 700mm, allowing for flexible
and convenient installation.
Fresh Air Intake
With optional installation of an air intake motor, fresh air
can enter through the cassette unit so you have fresher
air in the room.
Sub Duct
The Sub Duct lets you use the same air conditioner unit to
cool another smaller space nearby. (The cassette unit is
fitted with a knock-out component to accommodate this.)
Quick Connection of Drain Pipe
Samsung's unique drain pipe prevents leaks and is easier
to install with no need to use tape or adhesives.
FRESHFRESHFRESHFRESH
SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK
HIGHHIGHHIGHHIGH
Company A
Fresh air
Motor
Samsung
Cassette type Air conditioners
Samsung’s Ceiling type air conditioner offers four different types of models with stylish design
together with functionality. Indoor units that blends in and adds elegancy to any type of space
is the origin of the cool air that fills the entire space.
16
172009 Samsung Ceiling Air Conditioners
10. Slim 1Way Cassette
Super slim design helps easier installation and the quiet operation still provides the strongest air.
Slim and Compact Design
Slim 1Way Cassette
Want a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way
cassette type air conditioner is the answer.
10.5kg
17kg
38% Down
4kW R410A model Weight
Only 135mm thick
Samsung introduces the world's slimmest indoor
air conditioner unit. Only 135mm thick, the slim
1Way Cassette air conditioner can be installed
practically anywhere.
Lighter indoor unit
The first to apply ABS cabinets into its indoor
units, Samsung has achieved the lightest units
on the market. Its slim lightweight design makes
installation and maintenance a breeze.
Ensure that there is sufficient installation space. Allow at least
170mm for the installation.
NOTE
Min. 170mm
Quiet Operation
Samsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet.
25dB
35dB
30dB
43dB
Low
High
Fan speed Noise level
Check Valve Inside Drain Pump
Faulty drainage installation or power failures can cause condensed water to flow back into the unit,
causing leakage and odors. Samsung's air conditioners are equipped with a check valve built directly
into the drain pump to prevent water from flowing backward.
Check ValveOptional Accessories
PSSMAMR-CH01MWR-TH01 MWR-SH00
Individual
Controllers
Panel
WIDE BLADE
QUICK CONNECTION
OF DRAIN PIPE
CEILING SOILING
PREVENTION
HIGH LIFT-UP
DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK
18
192009 Samsung Ceiling Air Conditioners
MWR-WS00MWR-WE00
135mm
155mm
Drain pan is included within panel
11. Slim 1Way Cassette
Specification | Slim 1Way Cassette
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unit
SH026EAV1
UH026EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/2,600/3,500
950/3,300/4,600
245/695/1,120
210/910/1,300
3.74(A)
3.63(A)
1.6/3.3/5.2
1.4/5.3/6.4
6.35(1/4)
9.52(3/8)
1/220-240/50
SH026EAV1
PSSMA
CROSS FLOW FAN
8
970X135X410
1,164X212X478
10.0/13.6
1,180X25X460
1,250X126X530
3.1/4.5
30/25
DEFAULT
UH026EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
32.6/35.4
47
-10~43
-15~24
950
20
15
5
0
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unit
SH035EAV1
UH035EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/3,500/4,100
950/4,000/4,750
250/1,140/1,420
210/1,160/1,390
3.07(A)
3.45(A)
1.6/5.3/6.6
1.4/5.5/6.8
6.35(1/4)
9.52(3/8)
1/220-240/50
SH035EAV1
PSSMA
CROSS FLOW FAN
8.5
970X135X410
1,164X212X478
10.0/13.6
1,180X25X460
1,250X126X530
3.1/4.5
32/27
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
32.6/35.4
47
-10~43
-15~24
950
20
15
5
0
20
212009 Samsung Ceiling Air Conditioners
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
12. 4Way Cassette
With the air coming out from four different places, the 4Way Cassette type indoor units provide conditioned air to every
corner of the space.
Optional Accessories
Panel
New Turbo Fan
Quiet Operation
Imagine a room of cool calmness. The
aerodynamically designed ‘Turbo Fan'
minimizes noise from the turbulence
of blade movement. Therefore noise
is less than conventional models.
Uniform Distribution
The new 'Turbo Fan' with wide blades
provides extreme cooling and heating
power from 4 separate outlets so the
entire room gets cool or warm faster.
Now, every nook and cranny is
comfortable.
Easy Leveling
Each corner portion of the panel is detachable,
which gives easier access to adjust the height,
therefore leveling and installation is much easier
and quicker than before.
Compact Size
The 4Way cassette type unit has gotten even slimmer.
Now only 218mm thick (5.2/7.0/9.0kW), 24% slimmer
compare to competitor’s 288mm (9.0kW). It's still
the industry leader in compactness and is even
easier to install in tight spaces.
Efficient Cooling
3-dimensional shaped blade, which has the world wide patent, is able to spread cool or warm air further and
evenly to all corners of the space.
Conventional 4Way
Conventional 4Way
New 4Way
New 4Way
Detachable corners make installation
and height adjustments much easier.
Airdistribution
Detaching the whole panel took
more time.
218mm
Airdistribution
Outlet
1
Outlet
2
Outlet
3
Outlet
4
‘A’ View
‘B’ View
‘C’ View
WIDE BLADE
FRESH AIR
INTAKE
SUB DUCT
QUICK CONNECTION
OF DRAIN PIPE
CEILING SOILING
PREVENTION
HIGH LIFT-UP
DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK
P4SMA
Stylish Panel Design
The stylish panel is well harmonized with any interior design.
22
232009 Samsung Ceiling Air Conditioners
MR-CH01MWR-TH01 MWR-SH00
Individual
Controllers
MWR-WS00MWR-WE00
13. 24
252009 Samsung Ceiling Air Conditioners
4Way Cassette
Specification | 4Way Cassette
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unit
CH070EAV1
UH070EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
2,100/7,100/8,400
2,000/8,000/11,600
510/2,120/2,700
500/2,190/3,750
3.35(A)
3.65(A)
2.8/9.3/12.1
2.6/9.6/16.9
6.35(1/4)
15.88(5/8)
1/220-240/50
CH070EAV1
P4SMA
TURBO FAN
17.2
840X218X840
926X280X925
31/35
950X35X950
1,042X103X1,042
7.0/10.3
36/30
DEFAULT
UH070EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/61
52
-15~43
-20~24
1,900
50
30
5
30
CH090EAV
UH090EAV
3,200/9,000/10,000
3,000/10,000/13,900
750/2,800/3,200
580/2,770/4,660
3.21(A)
3.61(A)
3.5/12.5/14.1
2.8/12.2/20.6
9.52(3/8)
15.88(5/8)
1/220-240/50
CH090EAV
P4SMA
TURBO FAN
24
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
39/32
DEFAULT
UH090EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
95/110
56
-15~50
-20~24
2,600
75
30
7.5
40
CH105EAV
UH105EAV
3,200/10,500/12,000
2,600/11,200/15,500
700/3,270/3,800
580/3,100/5,600
3.21(A)
3.61(A)
3.3/14.5/16.8
3.6/13.7/24.3
9.52(3/8)
15.88(5/8)
1/220-240/50
CH105EAV
P4SMA
TURBO FAN
25.7
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
95/110
56
-15~50
-20~24
2,800
75
30
7.5
40
CH105EAV
UH105GAV
3,200/10,500/12,000
2,600/11,200/15,500
700/3,270/3,800
580/3,100/5,600
3.21(A)
3.61(A)
1.3/5.0/6.0
1.1/5.0/8.6
9.52(3/8)
15.88(5/8)
3/380-415/50
CH105EAV
P4SMA
TURBO FAN
22.2/25.7
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105GAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
88/93
56
-15~50
-20~24
2,800
75
30
7.5
40
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
CH140EAV
UH140EAV
3,800/14,000/15,400
3,450/16,000/18,500
900/4,650/5,400
750/4,690/5,800
3.01(B)
3.41(B)
4/20.6/23.5
3.6/20.8/26.5
9.52(3/8)
19.05(3/4)
1/220-240/50
CH140EAV
P4SMA
TURBO FAN
30
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
45/38
DEFAULT
UH140EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
105/120
59
-15~50
-20~24
3,100
75
30
7.5
40
CH140EAV
UH140GAV
3,800/14,000/15,400
3,450/16,000/18,500
900/4,650/5,400
750/4,690/5,800
3.01(B)
3.41(B)
4/20.6/23.5
3.6/20.8/26.5
9.52(3/8)
19.05(3/4)
3/380-415/50
CH140EAV
P4SMA
TURBO FAN
28/30
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
45/38
DEFAULT
UH140GAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
105/120
59
-15~50
-20~24
2,800
75
30
7.5
40
CH090EAS
UH090EAS
3,100/9,000/10,000
2,750/9,500/13,000
680/2,800/3,400
530/2,630/4,550
3.21(A)
3.61(A)
3.2/12.4/15.0
2.54/11.65/20.0
9.52(3/8)
15.88(5/8)
1/220-240/50
CH090EAS
P4SMA
TURBO FAN
24
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
39/32
DEFAULT
UH090EAS
TWIN BLDC
R410A
880x950x320
1043x1062x411
78/85
52
-15~50
-20~24
2,400
75
30
5
55
R-Inverter
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
14. 4Way Cassette
Specification | 4Way Cassette
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling/Heating
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unit
CH052EAMC
UH052EAMCModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
5,400
6,000
1,900
1,950
2.84(C)
3.08(D)
8.5
8.6
6.35(1/4)
12.7(1/2)
1/220-240/50
CH052EAMC
P4SMA
TURBO FAN
14
840X218X840
925X280X925
25/31
950X35X950
1,042X103X1,042
7.0/10.3
34/29
DEFAULT
UH052EAMC
ROTARY
R410A
880X648X310
1,023X744X413
59/66
49
-5~43
-5~24
1,500
30
15
7.5
25
CH070EAM1C
UH070EAM1C
7,000
7,200
2,400
2,350
2.92(C)
3.06(D)
11.0
11.0
6.35(1/4)
15.88(5/8)
1/220-240/50
CH070EAM1C
P4SMA
TURBO FAN
18.5
840X218X840
925X280X925
25/31
950X35X950
1,042X103X1,042
7.0/10.3
36/30
DEFAULT
UH070EAM1C
ROTARY
R410A
880X648X310
1,023X744X413
60/67
51
-5~43
-5~24
1,700
30
15
7.5
40
CH094EAMC
UH094EAM1C
9,000
9,500
3,400
3,500
2.65(D)
2.71(E)
15.5
16.0
6.35(1/4)
15.88(5/8)
1/220-240/50
CH094EAMC
P4SMA
TURBO FAN
21.5
840X218X840
925X280X925
25/31
950X35X950
1,042X103X1,042
7.0/10.3
39/32
DEFAULT
UH094EAM1C
ROTARY
R410A
880X798X310
1,023X891X413
74/82
55
-5~43
-5~24
1,800
30
15
7.5
50
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
CH105EAMC
UH105EAMC
10,000
10,700
3,830
3,850
2.61(D)
2.78(E)
17.5
17.5
9.52(3/8)
19.05(3/4)
1/220-240/50
CH105EAMC
P4SMA
TURBO FAN
24.5
840X298X840
925X360X925
28/34
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105EAMC
SCROLL
R410A
880X931X320
1,043X411X1,062
87/92
56
-5~43
-5~24
2,600
50
30
7.5
70
CH105EAMC
UH105GAMC
10,000
10,700
3,560
3,600
2.81(C)
2.97(D)
6.2
6.3
9.52(3/8)
19.05(3/4)
3/380-415/50
CH105EAMC
P4SMA
TURBO FAN
24.5
840X298X840
925X360X925
28/34
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105GAMC
SCROLL
R410A
880X931X320
1,043X411X1,062
87/92
56
-5~43
-5~24
2,750
50
30
7.5
70
CH140EAMC
UH140GAMC
14,000
15,400
5,300
5,900
2.64
2.61
9.2
10.0
9.52(3/8)
19.05(3/4)
3/380-415/50
CH140EAMC
P4SMA
TURBO FAN
29
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
45/38
DEFAULT
UH140GAMC
SCROLL
R410A
932X1,128X375
1,091X1,286X472
121/136
59
-5~43
-5~24
3,300
50
30
7.5
70
26
272009 Samsung Ceiling Air Conditioners
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
15. Mini 4Way Cassette
Four way airflow for large coverage with more compact size, it is best for the place with smaller ceiling structure.
FRESH AIR
INTAKE
QUICK CONNECTION
OF DRAIN PIPE
HIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH QUICKQUICKQUICKQUICK
High Energy Efficiency
Not only is the Mini 4Way cassette air conditioner small and compact, it's energy efficient. Easy operation coupled with
high efficiency provides you with remarkable performance at extremely low cost.
Fan Speed Adjustment
Fan speed can be adjusted by ceiling height. With an easy to
use PCB option, air flow can be altered for use in high ceilings.
Ideal Compact Size
The Mini 4Way cassette air conditioner can be installed in one standard ceiling
tile (600Wx600H) so construction or alterations to the ceiling are unnecessary.
3~3.5m 2.7m
High Ceiling
On : Increased fan speed Off : Standard fan speed
Unit : mm
Standard Ceiling
PMSMA
28
292009 Samsung Ceiling Air Conditioners
Optional Accessories
Panel
Specification | Mini 4Way Cassette
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unit
TH026EAV1
UH026EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
990/2,600/3,500
980/3,300/4,600
260/730/1,100
240/900/1,400
3.56(A)
3.67(A)
1.6/3.4/5.1
1.5/4.3/6.6
6.35(1/4)
9.52(3/8)
1/220-240/50
TH026EAV1
PMSMA
TURBO FAN
11.0
575X260X575
660X310X635
17/20
670X35X670
717X93X717
2.6/4.2
30/25
DEFAULT
UH026EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
32.6/35.4
47
-10~43
-15~24
950
20
15
5
0
TH035EAV1
UH035EAV1
990/3,500/4,200
980/4,000/5,000
260/1,090/1,400
250/1,100/1,400
3.21(A)
3.64(A)
1.6/5.0/6.4
1.5/5.1/6.7
6.35(1/4)
9.52(3/8)
1/220-240/50
TH035EAV1
PMSMA
TURBO FAN
12.0
575X260X575
660X310X635
17/20
670X35X670
717X93X717
2.6/4.2
34/27
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
32.6/35.4
47
-10~43
-15~24
950
20
15
5
0
TH052EAV1
UH052EAV1
1,050/4,700/6,300
1,300/5,500/8,600
420/1,460/2,150
350/1,590/2,950
3.22(A)
3.46(B)
2.4/7.0/10.0
2.6/8.0/15.0
6.35(1/4)
12.7(1/2)
1/220-240/50
TH052EAV1
PMSMA
TURBO FAN
12.9
575X260X575
660X310X635
17/20
670X35X670
717X93X717
2.6/4.2
41/33
DEFAULT
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
49
-15~43
-20~24
1,450
50
30
5
30
TH060EAV1
UH060EAV1
1,800/5,800/6,500
1,800/7,000/10,000
520/1,930/2,050
470/2,180/3,600
3.01(B)
3.21(C)
2.6/8.8/9.4
2.4/10.0/16.0
6.35(1/4)
15.88(5/8)
1/220-240/50
TH060EAV1
PMSMA
TURBO FAN
13.6
575X260X575
660X310X635
17/20
670X35X670
717X93X717
2.6/4.2
41/33
DEFAULT
UH060EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/61
52
-15~43
-20~24
1,900
50
30
5
30
MR-CH01MWR-TH01 MWR-SH00
Individual
Controllers
MWR-WS00MWR-WE00
Indoor Unit
Outdoor Unit
16. 2Way Cassette
Air coming out from two sides together with its size can be a perfect fit for long and narrow places with
limited installation space.
QUICK CONNECTION
OF DRAIN PIPE
HIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK
Small Size Big Performance
The 2Way cassette air conditioner is now 45% smaller than
competitor’s models, so it's even easier to incorporate into
building design.
Twin Cross Flow Fan
The 2Way cassette type unit is perfect fit for long and narrow
rectangular type of space. Twin Cross Flow Fan inside of the
2Way cassette will spread cool or warm air even further and
wider with less noise.
Standard Formula for Easy Installation
The dimensions of the 2Way cassette air conditioner allows for easy
installation into standard ceiling grids (600Wx600H), so everything
just falls into place.
230mm
890mm
575mm
45%
Decreased
305mm
1,180mm
600mm
600mm
600mm
Cross flow fans
P2SMA
30
312009 Samsung Ceiling Air Conditioners
Optional Accessories
Panel
Specification | 2Way Cassette
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unit
GH052EAMG
UH052EAMCModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
5,500
6,000
1,700
1,800
3.24(A)
3.33(C)
7.5
7.9
6.35(1/4)
12.7(1/2)
1/220-240/50
GH052EAMG
P2SMA
CROSS FLOW FAN
14
890X230X575
1,107X299X642
21/25
1,180X20X460
1,259X144X539
3.5/6.2
36/28
DEFAULT
UH052EAMC
ROTARY
R410A
880x648x310
1,023X744X413
59/66
49
-5~43
-5~24
1,500
30
15
7.5
25
GH070EAMG
UH070EAM1C
7,000
7,700
2,350
2,500
2.98(C)
3.08(D)
10.5
11
6.35(1/4)
15.88(5/8)
1/220-240/50
GH070EAMG
P2SMA
CROSS FLOW FAN
14
890X230X575
1,107X299X642
22/26
1,180X20X460
1,259X144X539
3.5/6.2
38/28
DEFAULT
UH070EAM1C
ROTARY
R410A
880x648x310
1,023X744X413
60/67
51
-5~43
-5~24
1,700
30
15
7.5
40
Individual
Controllers
Indoor Unit
Outdoor Unit
MR-CH01MWR-TH01 MWR-SH00MWR-WS00MWR-WE00
17. Duct type Air conditioners
With the widest range of products, Samsung’s duct type air conditioners are perfect for any space with
its slim size that offers flexible installation option. The smart pressure control system gives silent
operation so that the air conditioning never becomes a distraction.
Clean Filter System
The anti-bacteria filter and the filter cleaning indicator provide you with cleaner, healthier air.
You deserve to breathe fresh air everyday.
Anti-bacteria Filter
The anti-bacteria filter not only traps dust particles,
but suppresses proliferation of molds and bacteria.
BACTERIABACTERIABACTERIABACTERIA
Easy Filter Cleaning
After 1,000 hours of operation the filter clean
indicator will inform you that the filter should be
cleaned. The filter can be easily removed from
the bottom, left, or right of the unit. (1,000 hours
is the default set time, which can be adjusted to
2,000 hours on the internal PCB.)
High Lift-up Drain Pump (optional)
The lift-up drain pump lifts condensed water up to 750mm,
compared to the competitor’s 700mm, allowing for flexible and
convenient installation.
HIGHHIGHHIGHHIGH
Smart Pressure Control
The Smart Pressure Control System adjusts fan speed according to
E.S.P(External Static Pressure), so the air conditioner always gives
you consistent cooling and heating power regardless of the
surrounding environment.
E.S.P Control
Airvolume
Static pressure (mmAq)Minimum Maximum
H
H
M
M
L
L
WiredWiredWiredWired Wired Remote Controller
Wired remote controller is included for more convenient use of the air
conditioner.
32
332009 Samsung Ceiling Air Conditioners
18. Slim Design
Only 199mm thick, this slim design makes installation, maintenance,
and repair easy.
Easy to Maintain
Parts are easily accessible by
simply opening the bottom
panel, which reduces time
and maintenance costs.
199mm
199mm
220mm
225mm
160 180 200 220210 230
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
EASY FILTER
CLEANING
HIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH
SMART PRESSURE
CONTROL
Flexible Installation
The air inlet can be set up on either the bottom
or rear of the unit, so there is more flexibility in
installation.
Rear side air inlet Bottom side air inlet
Suction Duct Suction Duct
Tex
Tex
Diffuser Diffuser
Slim Duct
Slim duct type indoor units with industry leading compact size gives flexible installation and easier maintenance options.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
EH035EAV1
UH035EAV1
980/3,500/4,200
980/4,000/5,200
260/1,150/1,400
210/1,105/1,700
3.04(B)
3.62(A)
1.7/5.3/6.4
1.3/5.1/7.9
6.35(1/4)
9.52(3/8)
1/220-240/50
EH035EAV1
-
SIROCCO FAN
11.0
0/2/4
990X199X600
1,133X333X722
26/31
-
-
-
32/27
MDP-E075SEE
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
0
EH052EAV1
UH052EAV1
1,700/5,000/6,000
1,500/6,000/8,000
420/1,550/1,950
360/1,650/2,700
3.23(A)
3.64(A)
2.5/7.0/8.5
2.1/7.5/12.0
6.35(1/4)
12.7(1/2)
1/220-240/50
EH052EAV1
-
SIROCCO FAN
16.5
0/2/4
1,100X199X600
1,330X330X730
31/39
-
-
-
33/30
MDP-E075SEE
DEFAULT
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
49
-15~43
-20~24
1,450
50
30
5
30
EH070EAV1
UH070EAV1
2,200/7,100/8,000
2,000/8,000/12,000
570/2,200/2,650
500/2,150/3,800
3.23(A)
3.72(A)
2.9/10.0/12.0
2.8/10.0/16.5
6.35(1/4)
15.88(5/8)
1/220-240/50
EH070EAV1
-
SIROCCO FAN
19.6
0/2/4
1,100X199X600
1,330X330X730
31/39
-
-
-
36/32
MDP-E075SEE
DEFAULT
UH070EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/61
52
-15~43
-20~24
1,900
50
30
5
30
EH052EAMC
UH052EAMC
5,500
6,300
1,950
2,000
2.82
3.15
9.00
9.00
6.35(1/4)
12.7(1/2)
1/220-240/50
EH052EAMC
-
SIROCCO FAN
14.9
0/2/4
900X199X600
1,124X315X713
26/30
-
-
-
33/30
MDP-E075SEE
DEFAULT
UH052EAMC
ROTARY
R410A
880X648X310
1,023X704X413
59/66
49
-5~43
-5~24
1,500
30
15
7.5
40
EH070EAM1C
UH070EAM1C
6,800
7,500
2,420
2,420
2.81
3.10
11.10
11.10
6.35(1/4)
15.88(5/8)
1/220-240/50
EH070EAM1C
-
SIROCCO FAN
20.5
0/2/4
1,100X199X600
1,330X330X730
30.5/38.5
-
-
-
36/32
MDP-E075SEE
DEFAULT
UH070EAM1C
ROTARY
R410A
880X648X310
1,023X704X413
60/67
51
-5~43
-5~24
1,700
30
15
7.5
40
WIRED REMOTE
CONTROLLERWiredWiredWiredWired
Drain Pump
MDP-E075SEE / MDP-E075SEE1
Indoor Unit
Outdoor Unit
34
352009 Samsung Ceiling Air Conditioners
Optional Accessories
Specification | Slim Duct
Individual
Controllers
MR-CH01MWR-TH01MWR-WS00MWR-WE00
19. ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
EASY FILTER
CLEANING
HIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH
SMART PRESSURE
CONTROL
MSP Duct
Flexible installation options offer a variety of solutions for different shapes of room, and the smart pressure control
system provides quiet operation.
WIRED REMOTE
CONTROLLERWiredWiredWiredWired
Flexible Installation
Samsung's MSP Duct air conditioners offer different solutions
for any shape room allowing for specific airflow requirements.
L-shaped area Y-shaped areaAreas far apart
Silent Operation with the static pressure control
The external static pressure control makes it easy to design duct work to ensure efficiency and silent operation.
Narrow Width (5.2kW) Middle Static Pressure
900mm Slim Duct
mmAq
2
4
6
8
10
MSP Duct
0~10mmAq
0~6mmAq
Width measured without control box.
Easy to Maintain
Reduce time and maintenance costs
by keeping parts easily accessible.
R-Inverter
36
372009 Samsung Ceiling Air Conditioners
Drain Pump
MDP-M075SGU1 / MDP-M075SGU2 / MDP-M075SGU3
Optional Accessories
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
DH052EAS
UH052EAS
1,600/5,000/6,000
1,500/6,000/9,000
540/1,550/1,950
500/1,750/3,000
3.23(A)
3.43(B)
2.7/7.1/8.7
2.5/8.0/13.5
6.35(1/4)
12.70(1/2)
1/220-240/50
DH052EAS
-
SIROCCO FAN
16.5
0/4/6
900X260X480
1,146X363X584
29.5/34.5
-
-
-
37/33
MDP-M075SGU3
DEFAULT
UH052EAS
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
49
-10~43
-15~24
1,350
30
20
5
20
DH070EAS
UH070EAS
2,200/7,100/8,000
1,900/8,000/10,500
700/2,720/3,070
620/2,490/3,670
2.61(D)
3.21(C)
3.1/12.4/13.7
2.71/11.4/16.3
6.35(1/4)
15.88(5/8)
1/220-240/50
DH070EAS
-
SIROCCO FAN
21
0/4/6
900X260X480
1,146X363X584
29.5/34.5
-
-
-
38/34
MDP-M075SGU3
DEFAULT
UH070EAS
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
52
-10~43
-15~24
1,350
30
20
5
30
DH090EAS
UH090EAS
3,100/9,000/10,000
2,900/9,500,/13,000
850/3,200/3,600
680/2,960/4,650
2.81(C)
3.21(C)
3.82/14.0/15.8
3.1/13.0/20.5
9.52(3/8)
15.88(5/8)
1/220-240/50
DH090EAS
-
SIROCCO FAN
24
0/6/8
1,150X260X480
1,390x345x575
33/40
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH090EAS
TWIN BLDC
R410A
880x950x320
1,043x1,062x411
78/85
52
-15~50
-20~24
2,400
75
30
5
55
DH105EAS
UH105EAS
3,000/10,500/12,000
3,300/11,200/13,700
840/3,730/4,400
760/3,720/5,000
2.81(C)
3.01(D)
3.6/16.5/18.5
3.2/16.5/29.0
9.52(3/8)
15.88(5/8)
1/220-240/50
DH105EAS
-
SIROCCO FAN
24
0/6/8
1,150X260X480
1,390X345X575
34/40
-
-
-
40/33
MDP-M075SGU1
DEFAULT
UH105EAS
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
102/117
56
-15~50
-20~24
2,600
75
30
7.5
40
Indoor Unit
Outdoor Unit
Specification | MSP Duct
MR-CH01MWR-TH01
Individual
Controllers
MWR-WS00MWR-WE00
20. MSP Duct
Specification | MSP Duct
38
392009 Samsung Ceiling Air Conditioners
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
DH105EAV
UH105EAV
3,350/10,500/12,000
2,600/11,200/15,500
830/3,270/3,700
740/3,100/5,500
3.21(A)
3.61(A)
3.8/14.7/16.8
4.5/14.1/25.0
9.52(3/8)
15.88(5/8)
1/220-240/50
DH105EAV
-
SIROCCO FAN
28.1
0/8/10
1,150X320X480
1,396X424X584
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
102/117
56
-15~50
-20~24
2,800
75
30
7.5
40
DH105EAV
UH105GAV
3,350/10,500/12,000
2,600/11,200/15,500
830/3,270/3,700
740/3,100/5,500
3.21(A)
3.61(A)
1.4/5.0/6.1
1.3/5.0/8.5
9.52(3/8)
15.88(5/8)
3/380-415/50
DH105EAV
-
SIROCCO FAN
27.5/28.1
0/8/12
1,150X320X480
1,396X424X584
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105GAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
102/117
56
-15~50
-20~24
2,800
75
30
7.5
40
DH140EAV
UH140EAV
3,450/14,000/15,400
3,750/16,000/18,500
1,110/4,650/5,700
1,020/4,430/5,800
3.01(B)
3.61(A)
5.0/20.6/23.5
4.5/19.6/26.5
9.52(3/8)
19.05(3/4)
1/220-240/50
DH140EAV
-
SIROCCO FAN
36.8
0/8/10
1,200X360X650
1,447X425X769
55/60
-
-
-
43/38
MDP-M075SGU2
DEFAULT
UH140EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
105/120
59
-15~50
-20~24
3,100
75
30
7.5
40
DH140EAV
UH140GAV
3,450/14,000/15,400
3,750/16,000/18,500
1,110/4,650/5,700
1,020/4,430/5,800
3.01(B)
3.61(A)
1.8/7.4/8.8
1.7/7.0/9.5
9.52(3/8)
19.05(3/4)
3/380-415/50
DH140EAV
-
SIROCCO FAN
35.6/36.8
0/8/12
1,200X360X650
1,447X425X769
55/60
-
-
-
43/38
MDP-M075SGU2
DEFAULT
UH140GAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
105/120
59
-15~50
-20~24
2,800
75
30
7.5
40
Indoor Unit
Outdoor Unit
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
DH090EAV
UH090EAV
3,000/9,000/10,000
3,300/9,500/13,500
840/2,800/3,400
760/2,780/4,790
3.21(A)
3.41(B)
3.5/12.4/15.0
3.1/12.3/24.5
9.52(3/8)
15.88(5/8)
1/220-240/50
DH090EAV
-
SIROCCO FAN
24
0/6/8
1,150X260X480
1,390X345X575
33/40
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH090EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
102/117
56
-15~50
-20~24
2,600
75
30
7.5
40
DH070EAV1
UH070EAV1
2,200/7,100/8,000
1,900/8,000/11,000
600/2,210/2,600
470/2,210/3,700
3.21(A)
3.62(A)
2.9/10.0/12.0
2.8/10.0/16.5
6.35(1/4)
15.88(5/8)
1/220-240/50
DH070EAV1
-
SIROCCO FAN
19.6
0/4/8
1,150X260X480
1,390X345X575
34/40
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH070EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X406
57/61
52
-15~43
-20~24
1,900
50
30
5
30
DH052EAV1
UH052EAV1
1,700/5,000/60,00
1,700/6,000/8,300
550/1,560/1,950
480/1,760/2,750
3.21(A)
3.41(B)
3.1/7.5/9.3
2.6/8.4/13.1
6.35(1/4)
12.7(1/2)
1/220-240/50
DH052EAV1
-
SIROCCO FAN
16.5
0/4/6
900X260X480
1,146X363X584
29.5/34.5
-
-
-
37/33
MDP-M075SGU3
DEFAULT
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
49
-15~43
-20~24
1,450
50
30
5
30
Indoor Unit
Outdoor Unit
21. MSP Duct 40
412009 Samsung Ceiling Air Conditioners
Specification | MSP Duct
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
DH094EAMC
UH094EAM1C
8,800
9,500
3,650
3,500
2.41(E)
2.71(E)
16.5
15.5
9.52(3/8)
15.88(5/8)
1/220-240/50
DH094EAMC
-
SIROCCO FAN
24.4
0/6/8
1,150X260X480
1,390X345X575
34.5/40
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH094EAM1C
ROTARY
R410A
880X798X310
1,023X891X413
74/82
55
-5~43
-5~24
1,800
30
15
7.5
40
DH105EAMC
UH105EAMC
10,000
11,000
3,830
3,850
2.61(D)
2.86(D)
17.50
17.50
9.52(3/8)
19.05(3/4)
1/220-240/50
DH105EAMC
-
SIROCCO FAN
30
0/8/10
1,150X320X480
1,396X424X584
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105EAMC
SCROLL
R410A
880X931X320
1,043X411X1,062
87/92
56
-5~43
-5~24
2,600
50
30
7.5
40
Indoor Unit
Outdoor Unit
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
DH105EAMC
UH105GAMC
10,000
10,700
3,700
3,800
2.70(D)
2.82(D)
6.40
6.50
9.52(3/8)
19.05(3/4)
3/380~415/50
DH105EAMC
-
SIROCCO FAN
30
0/8/10
1,150X320X480
1,396X424X584
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105GAMC
SCROLL
R410A
880X931X320
1,043X411X1,062
87/92
56
-5~43
-5~24
2,750
50
30
7.5
40
DH140EAMC
UH140GAMC
14,700
16,000
5,500
5,700
2.67(D)
2.81(D)
9.50
10.20
9.52(3/8)
19.05(3/4)
3/380~415/50
DH140EAMC
-
SIROCCO FAN
38
0/8/15
1,200X360X650
1,447X425X769
52/60
-
-
-
43/38
MDP-M075SGU2
DEFAULT
UH140GAMC
SCROLL
R410A
932X1,128X375
1,091X1,286X472
121/136
59
-5 ~ 43
-5 ~ 24
3,300
50
30
7.5
40
Indoor Unit
Outdoor Unit
22. Floor & Convertible type Air conditioners
Convertible installation options, and the unique but functional design adds aesthetic
atmosphere to your interior while giving efficient cooling and heating.
I Interior Design
Now with more flexibility in placement, the air conditioner
can add a stylish element to your room.
INTERIORINTERIOR
DESIGNDESIGN
INTERIORINTERIOR
DESIGNDESIGN
Silent Mode
Indoor units operate quietly with the least
possible noise.
Anti-bacteria Filter
The anti-bacteria filter not only traps dust particles, but
suppresses proliferation of molds and bacteria.
BACTERIABACTERIABACTERIABACTERIA
Light Weight Unit
This extremely lightweight design makes maintenance
and installation easy.
LIGHTLIGHTLIGHTLIGHT
Flexible Pipe Installation
The drain pipe can be installed in 6 different places, so you
have more options in where to place your air conditioner.
Flexible PipeFlexible Pipe
InstallationInstallation
Flexible PipeFlexible Pipe
InstallationInstallation
Auto Changeover
The Auto Changeover automatically selects the operation
mode according to the temperature setting.
AUTOAUTOAUTOAUTO
Auto
Changeover
42
432009 Samsung Ceiling Air Conditioners
23. MPI Zone
Samsung's Micro Plasma Ion Zone is a technology that generates
activated hydrogen and oxygen ions, which exterminates viruses
and allergy-causing microbes in the air by neutralizing them and
turning into water.
Console
Unique design with the two air outlets on top and bottom side of the indoor unit provide more efficient
cooling and heating.
Optional Accessories
Elegant Design
Clean Panel
Stay clean with the smartly designed Clean
Panel. This unique panel keeps dust from
being accumulated so the unit and the room
stays cleaner.
Slim Design
It can't get any slimmer. This newly introduced
console type air conditioner is only 199mm
thick, the slimmest on the market. Its slim
design easily integrates the unit into your
decor.
Silent Operation (23dB)
The silent, yet powerful and efficient cooling and heating system
keeps things more comfortable. Silent mode is available in 4
different operating modes: High / Medium / Low / Silence.
2Way air outlets
There are two separate air outlets for cooling and heating. Having
warmer air coming out from the bottom part of the air outlet will
spread the warm air evenly throughout the room. Stay cooler and
warmer in every corner of your room.
Slim & Smart Design
This extremely slim design with Clean Panel adds aesthetic value to any interior.
199mm
Black Display
Functional art, the touch screen display is
elegant while it maximizes the convenience
of control.
INTERIOR
DESIGN
INTERIORINTERIOR
DESIGNDESIGN
INTERIORINTERIOR
DESIGNDESIGN
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
LIGHT WEIGHT
UNIT
LIGHTLIGHTLIGHTLIGHT
SILENT MODE
FLEXIBLE PIPE
INSTALLATIONFlexible PipeFlexible Pipe
InstallationInstallation
Flexible PipeFlexible Pipe
InstallationInstallation
WIRELESS REMOTE
CONTROLWirelessWirelessWirelessWireless
AUTO
CHANGEOVERAUTOAUTOAUTOAUTO
44
452009 Samsung Ceiling Air Conditioners
MWR-TH01
Individual
Controllers
MWR-WS00MWR-WE00
Standard Accessories
Wireless Remote
Controllers
24. Console
Specification | Console
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter(Catechin, Deodorizing)
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unit
JH026EAV1
UH026EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/2,600/3,600
950/3,500/4,600
230/670/1,040
210/970/1,250
3.88(A)
3.61(A)
1.5/3.3/4.9
1.4/4.7/6.2
6.35(1/4)
9.52(3/8)
1/220~240/50
JH026EAV1
-
TURBO FAN
8.1
720X620X199
810X710X295
15.2/20.3
-
-
-
38/23
DEFAULT
UH026EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
32.6/35.4
47
-10~43
-15~24
950
20
15
5
0
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter(Catechin, Deodorizing)
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
JH035EAV1
UH035EAV1
990/3,500/4,200
990/4,000/4,900
250/1,190/1,340
210/1,108/1,350
3.21(A)
3.61(A)
1.7/5.2/6.2
1.4/5.3/6.5
6.35(1/4)
9.52(3/8)
1/220~240/50
JH035EAV1
-
TURBO FAN
9
720X620X199
810X710X295
15.2/20.3
-
-
-
39/24
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
32.6/35.4
47
-10~43
-15~24
950
20
15
5
0
JH052EAV1
UH052EAV1
1,200/5,000/6,000
1,400/5,600/8,200
390/1,560/2,030
330/1,553/2,900
3.21(A)
3.61(A)
2.0/7.8/9.2
1.7/7.8/13.0
6.35(1/4)
12.7(1/2)
1/220~240/50
JH052EAV1
-
TURBO FAN
11.5
720x620x199
810x710x295
16/20.3
-
-
-
44/25
DEFAULT
UH052EAV1
SINGLE BLDC
R410A
880X638X310
1,023X704X413
52/56
49
-15~43
-20~24
1,450
50
30
5
30
46
472009 Samsung Ceiling Air Conditioners
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
25. Ceiling
Two way installation options allow the air coming out from the ceiling or floor.
INTERIOR
DESIGN
INTERIORINTERIOR
DESIGNDESIGN
INTERIORINTERIOR
DESIGNDESIGN
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
LIGHT WEIGHT
UNIT
LIGHTLIGHTLIGHTLIGHT FLEXIBLE PIPE
INSTALLATIONFlexible PipeFlexible Pipe
InstallationInstallation
Flexible PipeFlexible Pipe
InstallationInstallation
WIRELESS REMOTE
CONTROLWirelessWirelessWirelessWireless
AUTO
CHANGEOVERAUTOAUTOAUTOAUTO
Compact but Powerful
Samsung’s ceiling type air conditioner boasts a slim, compact
design, half the size of its competitors, with cooling power
comparable to competitor’s larger products.
2way Installation
Depending on the space availability and the purpose
of the air conditioner, the indoor unit can be installed
under the ceiling or on the floor.
Under Ceiling Floor Standing
48
492009 Samsung Ceiling Air Conditioners
Optional Accessories
MWR-WS00 MWR-TH01
Individual
Controllers
MR-CH01
Specification | Ceiling
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level 3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling 1)
Heating 2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unit
Outdoor unit
FH052EAV1
UH052EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3
/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
1,700/5,000/5,600
1,700/6,000/8,000
480/1,660/1,900
430/1870/3050
3.01(B)
3.21(C)
2.8/7.8/9.0
2.4/8.8/14.5
6.35(1/4)
12.7(1/2)
1/220-240/50
FH052EAV1
-
SIROCCO FAN
14.5
1,000X200X650
1,074X294X726
22/26
-
-
-
38/32
DEFAULT
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/54
49
-15~43
-20~24
1,450
50
30
5
30
FH070EAV1
UH070EAV1
2,000/7,100/8,000
2,000/8,000/11,000
590/2,520/2,900
450/2,750/3,750
2.81(C)
2.91(D)
3.0/11.0/13.0
2.9/12.5/17.0
6.35(1/4)
15.88(5/8)
1/220-240/50
FH070EAV1
-
SIROCCO FAN
16.0
1,000X200X650
1,074X294X726
22/26
-
-
-
41/36
DEFAULT
UH070EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/63
52
-15~43
-20~24
1,900
50
30
5
30
FH052EAMC
UH052EAMC
5,400
6,200
1,920
2,000
2.61(D)
3.10(D)
8.5
8.6
6.35(1/4)
12.7(1/2)
1/220-240/50
FH052EAMC
-
SIROCCO FAN
13.2
1,000X200X650
1,074X294X726
22/26
-
-
-
38/32
DEFAULT
UH052EAMC
ROTARY
R410A
880X648X310
1,023X744X413
59/66
49
-5~43
-5~24
1,500
30
15
7.5
25
FH070EAM1C
UH070EAM1C
6,700
7,200
2,480
2,550
2.70(D)
2.82(D)
11.4
11.5
6.35(1/4)
15.88(5/8)
1/220-240/50
FH070EAM1C
-
SIROCCO FAN
14.4
1,000X200X650
1,074X294X726
22/26
-
-
-
41/36
DEFAULT
UH070EAM1C
ROTARY
R410A
880X648X310
1023X744X413
60/67
51
-5~43
-5~24
1,700
30
15
7.5
40
200%
100%
136%
118% 123%
100%
Size
7.0kW Model
Weight
Smaller Lighter
Indoor Unit
Outdoor Unit
26. MDP-E075SEE
MDP-E075SEE1
MDP-M075SGU3
MDP-M075SGU1
MDP-M075SGU2
Slim duct
MSP duct
PVC Hose, 2.6kW~7.0kW
New Hose, 10.5kW~14.0kW
5.2kW~7.0kW
9.4kW~12.5kW
14.0kW~17.5kW
Duct Drain Pump
ModelClassification Compatible units Description
PSSMA
P2SMA
PMSMA
P4SMA
Unified Panel
Unified Panel
Unified Panel
Unified Panel
Single, DVM unified Panel
Single, Multi, DVM unified Panel
Single, Multi, DVM unified Panel
Single, Multi, DVM unified Panel
Slim 1Way Cassette
2Way Cassette
Mini 4Way Cassette
4Way Cassette
ModelClassification Compatible units Description
Drain Pump
Panel
MWR-WE00
MWR-WS00
MWR-TH01
MR-CH01
Unified Remote Controller
Unified Remote Controller
Unified Remote Controller
Unified Remote Controller
Individual and group control
Individual and group control
Individual and group control
Simple schedule control
Wired Remote Controller
Wireless Remote Controller
ModelClassification Compatible units Description
Remote Controller
50
512009 Samsung Ceiling Air Conditioners
Accessories
27. CONTROL SYSTEMS
02
52
532009 Samsung Ceiling Air Conditioners
Power of control,
within your hands
Samsung’s smart control system is the most convenient way
to control your system air conditioner. Control systems have
improved one step forward for better usability and
management for you to be able to control your air
conditioner practically anywhere and anytime.
| Control Systems
54
56
58
62
63
64
| Individual Control System
| Centralized Control System
| Integrated Management System
| Guest Room Management System
| DVM Pro
| Accessories
28. Individual Control System
Ergonomic and innovative remote controllers feature better design, easy grip, large and soft
buttons with easy-to-view displays.
Function Icon
ON/OFF, OPERATION MODE, FAN SPEED,
AIRFLOW, TEMPERATURE SETTING
OperationOperationOperationOperation
INDIVIDUAL AND GROUP CONTROL
(MAXIMUM 16 INDOOR UNITS)
GroupGroupGroupGroup
ERROR DISPLAY
ErrorErrorErrorError
FILTER REPLACEMENT ALARM RESET
FilterFilterFilterFilter
MWR-WS00 (Premium)
• Weekly schedule setting
(Maximum 70 schedules)
• Exception date setting
• Built-in room temperature
sensor
• Clear and bright screen with
LCD backlight
• Temperature limit setting
• Wireless remote control
restriction
• Automatic Stop mode
• Sleep and Silent mode
• Child lock
Wired Remote Controller
OperationOperationOperationOperation GroupGroupGroupGroup
ErrorErrorErrorError FilterFilterFilterFilter
OperationOperationOperationOperation GroupGroupGroupGroup
ErrorErrorErrorError FilterFilterFilterFilter
MR-CH01
• Simple schedule control
• Wide display
• Soft touch button
Wireless Remote Controller
OperationOperationOperationOperation FilterFilterFilterFilter
54
552009 Samsung Ceiling Air Conditioners
MWR-TH01
• Simple schedule control
• Wireless remote control
restriction
OperationOperationOperationOperation GroupGroupGroupGroup
ErrorErrorErrorError FilterFilterFilterFilter
MWR-WE00 (Multi function)
• Unified controller
(A/C, ERV, A/C+ERV)
• Different button permission
levels
• Weekly schedule setting
(A/C, ERV, A/C+ERV)
• Exception date setting
• Built-in room temperature
sensor
• Clear and bright screen
with LCD backlight
• Wireless remote control
restriction
• Automatic Stop mode
• Sleep and Silent mode
• Child lock
29. 56
572009 Samsung Ceiling Air Conditioners
Centralized Control System
Samsung's centralized control system can control and monitor up to 4,096 individual indoor units and 256 groups
of indoor units simultaneously with great convenience and efficiency.
Function Icon
ON/OFF, OPERATION MODE, FAN SPEED,
AIRFLOW, TEMPERATURE SETTING
OperationOperationOperationOperation
INDIVIDUAL AND GROUP CONTROL
(MAXIMUM 16 INDOOR UNITS)
GroupGroupGroupGroup
ERROR DISPLAY
ErrorErrorErrorError
FILTER REPLACEMENT ALARM RESET
FilterFilterFilterFilter
MCM-A202A
• Maximum 16 group controls (Maximum 256 Indoor units)
• Unified/Individual indoor unit control (On/Off)
• Wireless/wired remote control restriction
• Cooling/Heating mode control
• Indoor unit error display
Centralized Controller
MCM-A100
Function Controller
OperationOperationOperationOperation ErrorErrorErrorError FilterFilterFilterFilter
• Control and monitoring of
up to 16 indoor unit groups
To use Function Controller, it
requires to be connected to
MCM-A202A
• Communicator between
indoor/outdoor units and
the centralized controller
Interface Module
MIM-B04A
30. Integrated Management System
Integrated Management System is convenient for managing system air conditioners installed in small and middle-sized
buildings. It can be managed through the Internet so you can control the air conditioners from anywhere.
Data Management Server
DMS System
Max. 16 units
DMS
58
592009 Samsung Ceiling Air Conditioners
Web Server Function
• Built-in web server.
• Multiple upper-layer control access with prioritized management.
• Remote access control with the static IP address.
Internet
Anytime, Anywhere Control
Cooling
Schedule Setup
Power Distribution System
• Power distribution to up to 256 indoor units.
• Data query for watt-hour, use time and use ratio.
• File save in Microsoft Excel format.
• 93 days worth of power distribution data storage.
08:00 AM On 10:00 PM Off
External Contact Interface
• Full indoor unit control with simple contact input.
(Emergency/Lock)
• State output (Operation/Error) for synchronous
control.
Schedule Control Function
• Up to 256 schedule settings.
• Weekly, Daily or 1-Day schedule control.
• Exception date setting.
History Management
• Easy service and management with error history.
• Occurrence date, error details, current state.
Building Control System
Rapid Service Response
Error History Monitoring
Fire Control System Error Status Indicator
Operation Restriction
Service
Easy Control & Monitoring
• Individual/Group control and monitoring of up to 256 indoor units.
• Operation mode, temperature setting, airflow direction and
fan speed.
• Easy multiple/full indoor unit selection.
• Full room temperature display.
• Error history query based on date.
Enhanced central management
• Operation mode lock
• Temperature limit setting
• Wireless / wired remote control restriction
DMS
Easy Control & Monitoring
Web Server Function
Schedule Control Function
Power Distribution System
Building Management System
MIM-D00
• Built-in web server for PC-independent management and remote access
control
• Multiple upper-layer control access (S-NET 3, S-NET Mini, Web-client)
• Individual/Group control of up to 256 indoor units and heat exchange units
• Error history management
• Weekly/Daily schedule control
• Power distribution function
• 2 digital inputs, 2 digital outputs
• Current time management even during power failure (for 24 hours)
• Data storage in non-volatile memory
• Emergency stop function with simple contact interface
• Operation mode lock
• Temperature limit setting
360
kWh
460
kWh
140
kWh
Indoor unit operation state
1. Operation data accumulation and
power distribution
2.Data extract - Excel format
610
kWh
180
kWh
5th
Floor
4th
Floor
3rd
Floor
2nd
Floor
1st
Floor
31. Integrated Management System
You can manage a group of buildings with S-NET3 through Data Management Servers that manage each of the
buildings. S-NET3 provides flexible and complete control for a great variety of applications.
• Fully integrated PC management software.
• Up to 16 DMSs connection through the Ethernet.
• Central management of up to 4,096 indoor/heat
exchange units.
• Schedule/Zone control.
• Error/Operation history management.
• Power distribution management and analysis.
• Automatic update through the Internet.
S-NET 3
Data Management Server
S-NET 3 System
S-NET 3
Supports
16 DMSs
Max. 16 units
S-NET mini System
• Dynamic compatibility options
(DMS, centralized controller, interface module)
• Control and monitoring of up to 256 indoor units
• Detailed cycling information monitoring
• Schedule function (Weekly, Daily)
• USB keyboard support
• Error display
• 7-inch wide LCD display
• Temperature limit setting
• Touch screen
• Zone control
• Child-lock setting
• Operation mode lock
• External contact control
S-NET mini
Supports
16
Interface
Modules
Supports
16
Centralized
Controllers
Supports
4 DMSs
60
612009 Samsung Ceiling Air Conditioners
32. Guest Room Management System
The Guest Room Management System is a smart way to save energy and money. When the Key Tag is in place, the air
conditioner is activated. When the Key Tag is removed, the air conditioner switches off. Now you can avoid cooling an
unoccupied room and save energy.
MIM-B14
• Direct indoor unit control by external contact signal
• Window-synchronized indoor unit control
• Emergency control with simple contact input
• Indoor unit operation/error state output through relay contacts
62
632009 Samsung Ceiling Air Conditioners
Key-Tag
On/Off
Window Open
Sensor
Malfunction
Alarm
External device
Control
On/Off On/OffError
Example
DVM - Pro
(DVM, FJM, CAC Equipment Selection Software)
DVM-Pro consists of two kinds of software called DVM-Pro Sales and CAD mode.
DVM-Pro Sales mode
• Workspace: Creation ‘Project’ & ‚‘Workspace (DVM, FJM, CAC)’
• Indoor Unit: Indoor unit and accessory selection
• Outdoor Unit: Automatic selection and capacity simulation
• Piping: Basic, standard or manual selection with system check
• Wiring: Automatic diagram with communication wiring of indoor/
outdoor/control units and electric power meters
• Control system: Automatic control unit selection
• Report: Specifications, diagrams and quotation
Download!
www.dvmsystem.com Download Center DVM-Pro
DVM-Pro CAD mode
• Quick, easy, precise design
• Compatibility with AutoCAD
• Automatic calculation: Refrigerant & drain pipe size
• Automatic selection: Refnet joint, header & distributor kit
• System check: Installation regulation & refrigerant addition
• Simulation: System capacities
• Easy control system selection
• Automatic report: Piping installation diagram, equipment list & quotation
Contact to Samsung HQ or Distributors for DVM-Pro CAD!
33. 64
652009 Samsung Ceiling Air Conditioners
Accessories
Classification Product Model Image Application Model
Integrated
Management
System
Controller
DMS MIM-D00 CAC, FJM, DVM Series, ERV
CAC, FJM, DVM Series, ERV
CAC, FJM, DVM Series
S-NET 3 MST-P3P
S-NET Mini MST-S3W
Centralized
Control
System
Interface
Module
CAC, FJM, DVM Series, ERV
CAC, FJM, DVM Series
CAC, DVM, DVM PLUS, DVM HR
MCM-A202AController Centralized Controller
MCM-A100Function Controller
MIM-B04ACentralized Control Interface Module
CAC, DVM Plus II, DVM Plus III,
DVM Plus II HR, DVM Plus III HR,
Mini DVM (R410A), FJM(Non MH FKEA)
External Contact Interface Module MIM-B14Guest Room
Management
System
Individual
Control
System
Controller
Wireless Remote Controller MR-CH01 Cassette, Wall Mounted,
Ceiling, Duct (Receiver needed),
Console
Cassette, Wall Mounted, Ceiling,
Duct, Console
Cassette, Wall Mounted, Ceiling,
Duct, Console
Duct (For Wireless Remote Controller)
Duct (For Wireless Remote Controller)
Cassette, Wall Mounted, Ceiling,
Duct, Console
Wired Remote Controller (Premium) MWR-WS00
Wired Remote Controller MWR-TH01
Duct
Receiver Kit of
Wireless Remote
Controller
MRK-A00Receiver
of
Wireless Remote Controller
Receiver Wire MRW-10A
7-day Scheduler MWR-BS00
Cassette, Wall Mounted, Ceiling,
Duct, Console
Wired Remote Controller (Multi Function) MWR-WE00
DVM Series : Mini DVM, DVM, DVM PLUS, DVM HR, DVM PLUS II, DVM HR II, DVM PLUS III, DVM PLUS IIIHR
Icon Index
Cassette Type Icon
WIDE BLADE
Wider blades provide more
even cooling power.WIDEWIDEWIDEWIDE
CEILING SOILING
PREVENTION
Newly designed panel prevents
ceiling contamination.
HIGH LIFT-UP
DRAIN PUMP
Lift-up condensed water up
to 750mm higher than any
other competitor.
FRESH AIR INTAKE
Optional air intake motor
brings in fresh air from outside.
HIGHHIGHHIGHHIGH
FRESHFRESHFRESHFRESH
QUICK CONNECTION
OF DRAIN PIPE
Unique drain pipe connection
is easy to install.
QUICKQUICKQUICKQUICK
SUB DUCT
The Sub Duct makes it easy
to provide air conditioning to
a nearby smaller space.
SUB DUCTSUB DUCTSUB DUCTSUB DUCT
Duct Type Icon
ANTI-BACTERIA FILTER
Anti-bacteria Filter traps dust
particles and suppresses proliferation
of molds and bacteria.
EASY FILTER CLEANING
Filter cleaning indicator will
let you know when the filter
needs to be cleaned.
HIGH LIFT-UP DRAIN PUMP
Lift-up condensed water up
to 750mm higher than any
other competitor.
SMART PRESSURE CONTROL
Adjusts fan speed to provide
constant cooling and heating
performance.
BACTERIABACTERIABACTERIABACTERIA
HIGHHIGHHIGHHIGH
WIRED REMOTE CONTROLLER
Default wired remote controller
is provided.
WiredWiredWiredWired
Control Systems Icon
Floor & Convertible Type Icon
INTERIOR DESIGN
The clean, modern design
complements any decor.
LIGHT WEIGHT UNIT
Extremely lightweight, so
maintenance and installation
is easy.
ANTI-BACTERIA FILTER
Anti-bacteria Filter traps dust
particles and suppresses
proliferation of molds and bacteria.
INTERIORINTERIOR
DESIGNDESIGN
INTERIORINTERIOR
DESIGNDESIGN
BACTERIABACTERIABACTERIABACTERIA
AUTO CHANGEOVER
Automatically changes operation
mode according to temperature
setting.
AUTOAUTOAUTOAUTO
LIGHTLIGHTLIGHTLIGHT
FLEXIBLE PIPE
INSTALLATION
The pipe can be installed
in 6 different places for
more placement options.
SILENT MODE
Indoor and outdoor unit
operates silently.
Flexible PipeFlexible Pipe
InstallationInstallation
Flexible PipeFlexible Pipe
InstallationInstallation
WIRELESS REMOTE
CONTOLLER
Default wireless remote controller
is provided.
WirelessWirelessWirelessWireless
ON/OFF, OPERATION MODE,
FAN SPEED, AIR FLOW,
TEMPERATURE SETTING
OperationOperationOperationOperation INDIVIDUAL AND GROUP
CONTROL (MAXIMUM 16
INDOOR UNITS)
GroupGroupGroupGroup
ERROR DISPLAY
ErrorErrorErrorError
FILTER REPLACEMENT
ALARM RESET
FilterFilterFilterFilter
34. Samsung Electronics (UK) Ltd
Head Office Samsung House 1000 Hillswood Drive Chertsey Surrey KT16 0PS UK
Telephone 01932 455000 www.samsungac.co.uk