5. INTRODUCTION
Uses of column heads :
â˘increase shear strength of slab
â˘reduce the moment in the slab by reducing the clear or effective spanFlat slab with column head
6. INTRODUCTION
Uses of drop panels :
â˘increase shear strength of slab
â˘increase negative moment capacity of slab
â˘stiffen the slab and hence reduce deflection
8. BENEFITS
â˘Flexibility in room layout
â˘Saving in building height
â˘Shorter construction time
â˘Ease of installation of M&E services
â˘Prefabricated welded mesh
â˘Buildable score
9. Benefits . . .
FLEXIBILITY IN ROOM LAYOUT
â˘allows Architect to introduce partition walls anywhere required
â˘allows owner to change the size of room layout
â˘allows choice of omitting false ceiling and finish soffit of slab with skim coating
10. Benefits . . .
SAVING IN BUILDING HEIGHT
â˘Lower storey height will reduce building weight due to lower partitions and cladding to façade
â˘approx. saves 10% in vertical members
â˘reduce foundation load SlabSlabBeamBeam3.4m3.4m2.8m2.8mConventionalConventionalSlabSlab3.2m3.2m2.8m2.8mBeam-FreeBeam-Free
11. Benefits . . .
SHORTER CONSTRUCTION TIME
flat plate design will
facilitate the use of
big table formwork to
increase productivity
12. Benefits . . .
SINGLE SOFFIT LEVELLiving RoomLiving RoomToiletToiletShowerShowerKitchenKitchenYardYard30307575260260303030303030BalconyBalcony
155
FlatPlate Slab
Single Level
Ceiling
⢠Simplified the table formwork needed
13. Benefits . . .
EASE OF INSTALLATION
OF M&E SERVICES
â˘all M & E services can be mounted directly on the underside of the slab instead of bending them to avoid the beams
â˘avoids hacking through beams
14. Benefits . . .
PRE-FABRICATED WELDED MESHâ˘controlâ˘Prefabricated in standard sizesâ˘Minimised installation timeâ˘Better quality control
15. Benefits . . .
BUILDABLE SCORE
â˘allows standardized structural members and prefabricated sections to be integrated into the design for ease of construction
â˘this process will make the structure more buildable, reduce the number of site workers and increase the productivity at site
â˘more tendency to achieve a higher Buildable score
17. Design Considerations. . . .
WALL AND COLUMN POSITION
â˘Locate position of wall tomaximisethe structural stiffness for
lateral loads
â˘Facilitates the rigidity to be located to thecentreof buildingTypical floor plan of Compass the Elizabeth
18. Design Considerations. . . .
OPTIMISATION OF STRUCTURAL LAYOUT PLAN
â˘the sizes of vertical and structural structural members can be optimised to keep the volume of concrete for the entire superstructure inclusive of walls and lift cores to be in the region of 0.4 to 0.5 m3per square metre
â˘this figure is considered to be economical and comparable to an optimum design in conventional of beam and slab systems
19. Design Considerations. . . .
DEFLECTION CHECK
â˘necessary to include checking of the slab deflection for all load cases both for short and long term basis
â˘In general, under full service load, δ< L/250 or 40 mm whichever is smaller
â˘Limit set to prevent unsightly occurrence of cracks on non-structural walls and floor finishes
20. Design Considerations. . . .
CRACK CONTROL
â˘advisable to perform crack width calculations based on spacing of reinforcement as detailed and the moment envelope obtained from structural analysis
â˘good detailing of reinforcement will
ârestrict the crack width to within acceptable tolerances as specified in the codes and
âreduce future maintenance cost of the building
21. Design Considerations. . . .
FLOOR OPENINGS
â˘No opening should encroach upon a column head or drop
â˘Sufficient reinforcement must be provided to take care of stress concentration
22. Design Considerations. . . .
PUNCHING SHEAR
â˘always a critical consideration in flat plate design around the columns
â˘instead of using thicker section, shear reinforcement in the form of shear heads, shear studs or stirrup cages may be embedded in the slab to enhance shear capacity at the edges of walls and columns
24. Design Considerations. . . .
CONSTRUCTION LOADS
â˘critical for fast track project where removal of forms at early strength is required
â˘possible to achieve 70% of specified concrete cube strength within a day or two by using high strength concrete
â˘alternatively use 2 sets of forms
25. Design Considerations. . . .
LATERAL STABILITY
â˘buildings with flat plate design is generally less rigid
â˘lateral stiffness depends largely on the configuration of lift core position, layout of walls and columns
â˘frame action is normally insufficient to resist lateral loads in high rise buildings, it needs to act in tendam with walls and lift cores to achieve the required stiffness
28. Design methodology .. .
METHODS OF DESIGN
â˘the finite element analysis
â˘the simplified method
â˘the equivalent frame method
29. Design methodology .. .
FINITE ELEMENT METHOD
â˘Based upon the division of complicated structures into smaller and simpler pieces (elements) whose behaviour can be formulated.
â˘E.g of software includes SAFE, ADAPT, etc
â˘results includes
âmoment and shear envelopes
âcontour of structural deformation
35. Design methodology .. .
SIMPLIFIED METHOD
Table 3.19 may be used providedâ˘Live load > 1.25 Dead loadâ˘Live load (excluding partitions) > 5KN/m2â˘there are at least 3 rows of panels of approximately equal span in direction consideredâ˘lateral stability is independent of slab column connections
36. Design methodology .. ..
SIMPLIFIED METHOD
Table 3.19: BM and SF coefficients for flat slab or 3 or more equal spansOuter SupportColumnWallNear centreof 1st spanFirst interiorspanCentre ofinteriorspanInteriorspanMoment-0.04Fl*0.086Fl0.083Fl*-0.063Fl0.071Fl-0.055FlShear0.45F0.4F-0.6F-0.5FTotalcolumnmoments0.04Fl--0.022Fl-0.022Fl* the design moments in the edge panel may have to be adjusted according to 3.7.4.3F is the total design ultimate load on the strip of slab between adjacent columns considered(1.4gk + 1.6 qk) lis the effective span
37. Design methodology .. .
EQUIVALENT FRAME METHOD
â˘most commonly used method
â˘the flat slab structure is divided longitudinally and transversely into frames consisting of columns and strips of slabs with :
âstiffness of members based on concrete alone
âfor vertical loading, full width of the slab is used to evaluate stiffness
âeffect of drop panel may be neglected if dimension < lx/3
38. Design methodology .. .
EQUIVALENT FRAME METHOD
Plan of floor slab
Step 1 : define line of support in X & Y directions
39. Design methodology .. .
EQUIVALENT FRAME METHOD910109.20.8DESIGN STRIP IN PROTOTYPE91010.610.50.8STRAIGHTENED DESIGN STRIPDESIGN STRIP IN ELEVATION
Step 2 : define design strips in X & Y directions
41. Analysis of flat slab..
COLUMN HEADlholh maxlcdh(i)lh= lh, maxlholh maxlcdh(ii)lh= lhoEffective dimension of a head , where lho = actual dimension, lh max= lc+ 2(dh-40) lh (mm)= lesser of lho orlh max
42. Analysis of flat slab..
COLUMN HEADlholh maxlcdh(iv)lh= lholholh maxlcdh40(iii)lh= lh, maxFor circular column or column head, effective diameter ,hc= 4 x area/Îż< 0.25 lx
43. Analysis of flat slab..
DIVISION OF PANELS
The panels are divided into âcolumn stripsâ and middle stripsâ in both direction.
(a)Slab Without Dropslx/4 Column strip Column striplx/4lx/4lx/4middle strip (ly-lx/2) middlestrip lx (shorter span) ly (longer span)
44. Analysis of flat slab..
lx Dropmiddle strip (ly-drop size) lx/4Column strip = drop sizemiddlestriply (longer span) note : ignore drop if dimension is less than lx/3 Drop (b)Slab With Drops
45. Analysis of flat slab..
MOMENT DIVISIONApportionment between columnand middle strip expressed as % of the total negative designmomentColumn stripMiddle stripNegative75%25% Positive55%45% â˘Note : For slab with drops where the width of the middle strip exceeds L/2, the distribution of moment in the middle strip should be increased in proportion to its increased width and the momentresisted by the column strip should be adjusted accordingly.
46. Analysis of flat slab..
MOMENT DIVISION -EXAMPLE
6000
6000
6000
6000
6000
5000
Layout of building
7000
5000
A floor slab in a building where stability is provided by shear walls in one direction (N-S). The slab is without drops and is supported internally and on the external long sides by square columns . The imposed loading on the floor is 5 KN/m2and an allowance of 2.5KN/m2for finishes, etc. fcu = 40 KN/m2, fy = 460KN/m2
47. Analysis of flat slab..
MOMENT DIVISION -EXAMPLE250030002500
6000
6000600060005000700025001500275040001250
3500
3000
3500
Division of panels into strips in x and y direction
48. Analysis of flat slab..
MOMENT DIVISION -EXAMPLE
6000250035003000300025003500
60003520020036920020035
Column strip
exterior support = 0.75*35 on 2.5m strip = 10.5Knm
centre of 1st span= 0.55*200 on 2.5 strip = 44KNm
1st interior support = 0.75*200 on 3m strip = 50KNm
centre of interior span = 0.55 *369 on 3m strip = 67.7KNm
Middle strip
exterior support = 0.25*35 on 2.5m strip = 3.5KNm
centre of 1st span= 0.45*200 on 2.5 strip = 36KNm
1st interior support = 0.25*200 on 3m strip = 16.7KNm
centre of interior span = 0.45 *369 on 3m strip = 55.4KNm
49. Analysis of flat slab..
DESIGN FOR BENDING
INTERNAL PANELS
â˘columns and middle strips should be designed to withstand design moments from analysis
50. Analysis of flat slab..
DESIGN FOR BENDING
EDGE PANELSâ˘apportionment of moment exactly the same as internal columnsâ˘max. design moment transferable between slab and edge column by a column strip of breadth beis < 0.5 design moment (EFM) < 0.7 design moment (FEM) Otherwise structural arrangements shall be changed. Mt, max= 0.15 bed2fcu
51. Analysis of flat slab..
PUNCHING SHEAR
1.CalculateVeff =kVt at column perimeter (approx. equal span)
Vt = SF transferred from slab
k = 1.15 for internal column, 1.25 corner columns and edge columns where M acts parallel to free edge and 1.4 for edge columns where M acts at right angle to free edge
2.Determine vmax= Veff /uodwhere uo is the length of column perimeter
Check vma < 0.8fcu or 5 N/mm2
3.Determine v=(Veff -V/ud)where uis the length of perimeter A and V is the column load and checkv< vc
4.Repeat step 3 for perimeter B and CColumn perimeterPerimeter APerimeter B3d23d4Column perimeterPerimeter APerimeter BPerimeter C3d23d43d4)lx/3
52. Analysis of flat slab..
DEFLECTION
(i) use normal span/effective depth ratio if drop width >1/3 span each way; otherwise(ii) to apply 0.9modification factor for flat slab, orwhere drop panel width < L/31.0otherwiseSpan/depth ratioCantilever7Simply supported20Continuous26
53. Holes in areas bounded by the column stripsmay be formedproviding : â˘greatest dimension < 0.4 span lengthandâ˘total positive and negative moments are redistributed between the remaining structure to meet the changed conditionsOPENINGSAnalysis Analysis of flat slab.. ly (longer span) lx (shorter span)
54. OPENINGSAnalysis Analysis of flat slab.. Holes in areas common to two column stripsmay be formed providing : â˘that their aggregate their length or width does not exceed one-tenth of the width of the column strip; â˘that the reduced sections are capable of resisting with the moments; andâ˘that the perimeter for calculating the design shear stress is reduced if appropriately (longer span) lx (shorter span)
55. OPENINGSAnalysis Analysis of flat slab.. ly (longer span) lx (shorter span)
Holes in areas common to the column strip and the middle stripmay
be formed providing :
â˘that in aggregate their length or width does not exceed one-quarter of the width of the column strip and
â˘that the reduced sections are capable of resisting the design moments
56. OPENINGSAnalysis Analysis of flat slab..
For all other cases of openings, it should be framed on
all sides with beams to carry the loads to the columns.
58. Detailing of flat slab .. .
TYPE OF REINFORCEMENT
F-mesh-A mesh formed by main wire with cross wire
at a fixed spacing of 800 mm
mesh - #Main wire-hard drawn ribbed wire with diameter and
spacing as per design
wire - #Cross wire-hard drawn smooth wire as holding wire
wire - H8-800mm c/c for main wire diameter > 10mm
H7-800mm c/c for main wire diameter of 10mm
and below
59. Detailing of flat slab .. .
TYPE OF REINFORCEMENT Main WireHolding WireF-Mesh 2Holding Wire (800mm c/c) Main WireF-Mesh 1
65. Detailing of flat slab .. .
REINFORCEMENT
FOR INTERNAL PANELS
â˘Reinforcement are arranged in 2 directions parallel to each span; and
â˘2/3 of the reinforcement required to resist negative moment in the column strip must be placed in the centre half of the strip
â˘for slab with drops, the top reinforcement should be placed evenly across the column strip