This document provides installation and operation instructions for a Z100VX series vortex flow meter. Key points include:
1. The flow meter uses the Karman vortex principle to measure liquid, gas, and steam flow rates. Proper installation is required to avoid measurement errors.
2. Straight pipe runs of at least 10 diameters upstream and 5 diameters downstream are recommended. Ensure the pipes remain fully filled and avoid locations with pulsating flow.
3. When measuring liquid flow, backpressure of at least 1.25 times the vapor pressure plus twice the pressure drop through the meter is needed to prevent cavitation.
4. The flow meter has models for different pipe sizes, connections, display/output options,
This document provides installation and operation instructions for a Vortex Flow Meter. It discusses general information about the product, technical specifications, model selection details, cautions for installation, electrical wiring, programming and setup, and troubleshooting. The key points are that the flow meter works based on the Karman vortex principle, requires a minimum of 10 diameters of straight pipe upstream and 5 diameters downstream to achieve accurate measurements, and the installation must ensure the pipes remain fully filled with liquid to avoid measurement errors.
Schubert & Salzer is a fast growing high-tech company, that develops, produces and distributes highly precise control and stop valves which are applied in the process industry.
Regulatory modifications have raised important issues in design and use of industrial safety systems. Certain changes in IEC 61508, now being widely implemented, mean that designers and users who desire full compliance must give new consideration to topics such as SIL levels and the transition to new methodologies.
Nomenclature of check valves by vickers, eatonpuneet8589
Vickers check valves come in inline, right angle, and manifold mounted designs. Right angle check valves are designed for higher flows with less pressure drop than inline models. They have hardened and ground steel seats and poppets for improved cycle life. Pilot operated check valves allow reverse flow when a pilot pressure signal is applied, while maintaining very low internal leakage. They are typically used to lock cylinders in place.
This document is a test report that evaluates LED recessed luminaires according to various safety standards, including IEC 60598-2-2. It provides details of the test items, tests performed, results, and compliance of the luminaires with requirements. The luminaires passed all tests, including tests of markings, protection against electric shock, moisture resistance, heat resistance, flame resistance, and photobiological safety. National differences for Germany were also addressed.
Tests were conducted on cylindrical lithium-ion cells to evaluate compliance with safety standard IEC 62133. Key tests included continuous charging, external short circuit, free fall, thermal abuse, crush, forced discharge, transport, and forced internal short circuit. All tests were completed from November 1-10, 2014 at the TÜV Rheinland Shenzhen testing facility and the cells met all requirements with no fire, explosion, physical distortion or exposure of internal components. An attachment included two photos documenting the testing.
SMC -Refrigerated Air Dryers Standard/High Temperature Air Inlet Type Standar...PHỤ TÙNG CÔNG NGHIỆP
1. The document provides specifications for Kobelco refrigerated air dryers, including the IDF and IDU series.
2. It lists the available models in each series, their applicable air flow capacities, refrigerants used, and inlet port sizes.
3. Correction factors are provided to adjust the rated air flow capacity based on the user's operating conditions of inlet air temperature, ambient temperature, outlet pressure dew point, and inlet air pressure.
The test report summarizes safety testing performed on LCD TV models 32C21, 32C12, and 32C51 manufactured by PCF Technology Development(Shenzhen) Limited according to IEC 60065. The samples were tested for durability of marking, temperature rise, touch current, insulation requirements, mechanical safety, and other tests. The samples were found to comply with the requirements of IEC 60065. The report also lists national differences for various countries that are applicable to the standard.
This document provides installation and operation instructions for a Vortex Flow Meter. It discusses general information about the product, technical specifications, model selection details, cautions for installation, electrical wiring, programming and setup, and troubleshooting. The key points are that the flow meter works based on the Karman vortex principle, requires a minimum of 10 diameters of straight pipe upstream and 5 diameters downstream to achieve accurate measurements, and the installation must ensure the pipes remain fully filled with liquid to avoid measurement errors.
Schubert & Salzer is a fast growing high-tech company, that develops, produces and distributes highly precise control and stop valves which are applied in the process industry.
Regulatory modifications have raised important issues in design and use of industrial safety systems. Certain changes in IEC 61508, now being widely implemented, mean that designers and users who desire full compliance must give new consideration to topics such as SIL levels and the transition to new methodologies.
Nomenclature of check valves by vickers, eatonpuneet8589
Vickers check valves come in inline, right angle, and manifold mounted designs. Right angle check valves are designed for higher flows with less pressure drop than inline models. They have hardened and ground steel seats and poppets for improved cycle life. Pilot operated check valves allow reverse flow when a pilot pressure signal is applied, while maintaining very low internal leakage. They are typically used to lock cylinders in place.
This document is a test report that evaluates LED recessed luminaires according to various safety standards, including IEC 60598-2-2. It provides details of the test items, tests performed, results, and compliance of the luminaires with requirements. The luminaires passed all tests, including tests of markings, protection against electric shock, moisture resistance, heat resistance, flame resistance, and photobiological safety. National differences for Germany were also addressed.
Tests were conducted on cylindrical lithium-ion cells to evaluate compliance with safety standard IEC 62133. Key tests included continuous charging, external short circuit, free fall, thermal abuse, crush, forced discharge, transport, and forced internal short circuit. All tests were completed from November 1-10, 2014 at the TÜV Rheinland Shenzhen testing facility and the cells met all requirements with no fire, explosion, physical distortion or exposure of internal components. An attachment included two photos documenting the testing.
SMC -Refrigerated Air Dryers Standard/High Temperature Air Inlet Type Standar...PHỤ TÙNG CÔNG NGHIỆP
1. The document provides specifications for Kobelco refrigerated air dryers, including the IDF and IDU series.
2. It lists the available models in each series, their applicable air flow capacities, refrigerants used, and inlet port sizes.
3. Correction factors are provided to adjust the rated air flow capacity based on the user's operating conditions of inlet air temperature, ambient temperature, outlet pressure dew point, and inlet air pressure.
The test report summarizes safety testing performed on LCD TV models 32C21, 32C12, and 32C51 manufactured by PCF Technology Development(Shenzhen) Limited according to IEC 60065. The samples were tested for durability of marking, temperature rise, touch current, insulation requirements, mechanical safety, and other tests. The samples were found to comply with the requirements of IEC 60065. The report also lists national differences for various countries that are applicable to the standard.
This document provides information on solenoid valves from Asconumatics including:
- Power levels range from 0.5W to 11.2W for basic, medium, reduced, and low power valves.
- Valves are certified to safety standards like IEC 61508 and have explosion proof, flame proof, and other options.
- Technical specifications include flow rates, pressure ranges, materials, temperature ranges, electrical characteristics and more.
- Selection information includes identifying the basic catalogue number, prefixes for additional options, suffixes, voltage, and ordering format.
Ashcroft Pressure Gauges - Air Conditioning, Heating & Refridgeration Industr...Thorne & Derrick UK
This document provides information on instrumentation products from Ashcroft for the air conditioning, heating and refrigeration industries. It describes their line of pressure gauges, switches, transmitters and temperature instruments. It highlights that their products are designed to meet the stringent demands of these industries and provide accurate measurements with features like the PowerFlex movement, FlutterGuard and True Zero indication. It also provides specifications and details on various models.
This document specifies requirements for steel sheet used in pressure vessels. It defines 7 grades of carbon steel based on minimum tensile and yield strengths. Chemical compositions and mechanical properties are specified for each grade. Test procedures define how samples are taken and properties measured. Requirements cover ordering, dimensions, markings, inspections, certifications and other aspects of manufacturing the steel sheets according to this specification.
The Soliwave FQR56/FDR56 microwave barrier uses a contact-free procedure for level detection. The FQR56 emitter transmits a 24.15 GHz signal that the FDR56 receiver detects to determine if material is present. The system can detect through non-metallic containers from up to 100m away and is suitable for bulk solids or piece goods level detection. It has multiple installation options including direct installation with threading, bracket mounting, or flange mounting.
This document provides information on a falling film evaporator vessel including:
- The vessel number, customer, designer, date, location, and purchaser.
- A nozzle schedule listing 16 nozzles of various sizes and materials including vapor outlets, condensate outlets, spray nozzles, and vents.
- Deficiencies noted for the heat exchanger including baffle thickness being less than the minimum required thickness.
This document summarizes solenoid valve manifolds that simplify installation while reducing costs. The modular design allows for different valve options in a single manifold. Manifolds come in 2-way and 3-way options with various port sizes and flow rates. They improve system reliability and reduce potential leak paths. Typical applications include assembly cells, service carts, and industrial equipment.
Metso Neles Flow Control Solutions: Valves, Actuation, and AutomationMead O'Brien, Inc.
Neles Controls, a unit of Metso Automation, is a manufacturer of high quality rotary control valves, on/off valves, actuators & positioners, emergency shutdown valves (ESD), digital valve position control products, and severe service specialty valve products.
The document provides information on various monitoring devices from Siemens, including:
- Fault signaling units that monitor industrial plants and control systems and indicate faults.
- Dusk switches that control lighting installations for energy savings based on daylight levels.
- Temperature controllers, fuse monitors, voltage and current relays, insulation monitors and other devices that monitor various electrical parameters.
Technical specifications, usage, standards, and ordering information are provided for each type of monitoring device.
Dienhathe.com miniature circuit breakersDien Ha The
This document provides an overview of Siemens miniature circuit breakers, including their standard, high-capacity, universal current, high current, and power supply company product ranges. It describes the benefits of the circuit breakers, such as their high rated breaking capacity, excellent current limitation, and individually mountable additional components. Technical specifications are provided for the different product lines, including their tripping characteristics, voltages, terminals, and environmental resistance.
Asco Du Atex Explosion Proof Operator Hazardous Area Solenoid Valve Operator ...Thorne & Derrick UK
B
15
15
15
15
C
30
40
40
40
D
64
84
89
95
E
22
22
22
22
F
4.5
6
6
6
G
0
0
0
0
R
180°
180°
180°
180°
weight (kg)
0.15
0.25
0.3
0.4
- The document provides specifications for series DU and SCDU explosionproof operators for use in potentially explosive atmospheres.
- The operators comply with ATEX Directive 94/9/EC and have
buttons puccini, connection cable, control units, device board, display interface, drinking water at home, environment, female connector, filters for drinking water, h2o, health water, high pressure volumetric counter, interface for payment system executive, level regulator, level sensor, probe, public fountain, public fountain kit 24 vac, technical kit buttons and display, water dispenser
We are a products, solutions and services wholesale supplier in water treatment. We provide only businesses companies such as distributors, retailers, manufacturers and assemblers.A catalog including carefully selected products, from the most prestigious brands in the Water Treatment market, operative website, personalized services, precise and efficient logistics, flexible organization, but also the basic importance that is attributed to human factors and relationships with partners, make of Sinergroup Srl a reference for many companies of the market. A continuous and consistent effort, the ability to anticipate the evolution of the market demand and orientation to the understanding and satisfaction of our customers has always characterizes us in our work.
Born with the objective view in the exclusive distribution: Continue to be "Leader of the Brand Leader ", with activities and services of value. A choice of specialization that in recent years has allowed us to develop a unique knowledge and experience in the market. The thorough water treatment market understanding and high commercial performance, make us able to offer to our customers many products and services more personalized and appropriate to the individual end user. Our mission is to become your best business Partner!
The NDX is a 4–20 mA powered micro-controller based intelligent valve controller. The device contains a local user interface enabling configuration and operation without opening the device cover. Configuration and operation can also be made remotely by PC with asset management software connected to the control loop.
The document provides an overview of Siemens' miniature circuit breaker product range, including standard, high-capacity, universal current, high current, and power supply company product lines. It lists the technical specifications for each product line, including rated currents and voltages, tripping characteristics, terminals, approvals, and more. The benefits of the circuit breakers include high rated breaking capacity, excellent current limitation, different tripping characteristics, safety-compliant terminals, uniform additional components, and fast installation. The circuit breakers are designed to protect electrical equipment from overheating and leakage currents.
This document provides specifications and installation instructions for the HERZ-Motorised flow controller. The controller is a pressure independent balancing control valve (PIBCV) used to automatically maintain and balance flow rates in heating, cooling, and water systems. It works by measuring and adjusting to pressure variations to achieve the set flow rate. The document describes the device dimensions and technical specifications, materials, recommended installation procedures, accessories, and application examples.
The document provides information about the Liquiphant M Density and Density Computer FML621 for measuring the density of liquids. The system uses a Liquiphant M sensor with an electronic insert to measure density via pulse output. The Density Computer FML621 receives this input and can output the density measurement on current/pulse outputs. It also enables additional calculations and conversions of the density measurement. The document discusses the measuring principles, system design, inputs/outputs, installation, performance specifications, and accessories of the devices.
The Variable Area flowmeter is an instrument for metering the flowrate of liquids and gases in a pipeline. It includes a vertically oriented conical tube, whose diameter is larg- er at the top than at the bottom, through which the fluid flows upward and in which a vertically moving float is positioned.
Due to its full metal design, the SITRANS FVA250 variable area meter with a standard length of 250 mm (9.84 inch) can be used to measure many different types of liquids and gases passing through closed piping. The robust design means that it can also be used in harsh conditions. The various types of flange connec- tions, linings and float materials satisfy the requirements of the pharmaceutical and chemical industries.
The measured value is displayed directly on the scale with the standard version. For process monitoring and control, the device can be equipped with a transmitter (MEM) as well as limit switches.
This document provides information on solenoid valves from Asconumatics including:
- Power levels range from 0.5W to 11.2W for basic, medium, reduced, and low power valves.
- Valves are certified to safety standards like IEC 61508 and have explosion proof, flame proof, and other options.
- Technical specifications include flow rates, pressure ranges, materials, temperature ranges, electrical characteristics and more.
- Selection information includes identifying the basic catalogue number, prefixes for additional options, suffixes, voltage, and ordering format.
Ashcroft Pressure Gauges - Air Conditioning, Heating & Refridgeration Industr...Thorne & Derrick UK
This document provides information on instrumentation products from Ashcroft for the air conditioning, heating and refrigeration industries. It describes their line of pressure gauges, switches, transmitters and temperature instruments. It highlights that their products are designed to meet the stringent demands of these industries and provide accurate measurements with features like the PowerFlex movement, FlutterGuard and True Zero indication. It also provides specifications and details on various models.
This document specifies requirements for steel sheet used in pressure vessels. It defines 7 grades of carbon steel based on minimum tensile and yield strengths. Chemical compositions and mechanical properties are specified for each grade. Test procedures define how samples are taken and properties measured. Requirements cover ordering, dimensions, markings, inspections, certifications and other aspects of manufacturing the steel sheets according to this specification.
The Soliwave FQR56/FDR56 microwave barrier uses a contact-free procedure for level detection. The FQR56 emitter transmits a 24.15 GHz signal that the FDR56 receiver detects to determine if material is present. The system can detect through non-metallic containers from up to 100m away and is suitable for bulk solids or piece goods level detection. It has multiple installation options including direct installation with threading, bracket mounting, or flange mounting.
This document provides information on a falling film evaporator vessel including:
- The vessel number, customer, designer, date, location, and purchaser.
- A nozzle schedule listing 16 nozzles of various sizes and materials including vapor outlets, condensate outlets, spray nozzles, and vents.
- Deficiencies noted for the heat exchanger including baffle thickness being less than the minimum required thickness.
This document summarizes solenoid valve manifolds that simplify installation while reducing costs. The modular design allows for different valve options in a single manifold. Manifolds come in 2-way and 3-way options with various port sizes and flow rates. They improve system reliability and reduce potential leak paths. Typical applications include assembly cells, service carts, and industrial equipment.
Metso Neles Flow Control Solutions: Valves, Actuation, and AutomationMead O'Brien, Inc.
Neles Controls, a unit of Metso Automation, is a manufacturer of high quality rotary control valves, on/off valves, actuators & positioners, emergency shutdown valves (ESD), digital valve position control products, and severe service specialty valve products.
The document provides information on various monitoring devices from Siemens, including:
- Fault signaling units that monitor industrial plants and control systems and indicate faults.
- Dusk switches that control lighting installations for energy savings based on daylight levels.
- Temperature controllers, fuse monitors, voltage and current relays, insulation monitors and other devices that monitor various electrical parameters.
Technical specifications, usage, standards, and ordering information are provided for each type of monitoring device.
Dienhathe.com miniature circuit breakersDien Ha The
This document provides an overview of Siemens miniature circuit breakers, including their standard, high-capacity, universal current, high current, and power supply company product ranges. It describes the benefits of the circuit breakers, such as their high rated breaking capacity, excellent current limitation, and individually mountable additional components. Technical specifications are provided for the different product lines, including their tripping characteristics, voltages, terminals, and environmental resistance.
Asco Du Atex Explosion Proof Operator Hazardous Area Solenoid Valve Operator ...Thorne & Derrick UK
B
15
15
15
15
C
30
40
40
40
D
64
84
89
95
E
22
22
22
22
F
4.5
6
6
6
G
0
0
0
0
R
180°
180°
180°
180°
weight (kg)
0.15
0.25
0.3
0.4
- The document provides specifications for series DU and SCDU explosionproof operators for use in potentially explosive atmospheres.
- The operators comply with ATEX Directive 94/9/EC and have
buttons puccini, connection cable, control units, device board, display interface, drinking water at home, environment, female connector, filters for drinking water, h2o, health water, high pressure volumetric counter, interface for payment system executive, level regulator, level sensor, probe, public fountain, public fountain kit 24 vac, technical kit buttons and display, water dispenser
We are a products, solutions and services wholesale supplier in water treatment. We provide only businesses companies such as distributors, retailers, manufacturers and assemblers.A catalog including carefully selected products, from the most prestigious brands in the Water Treatment market, operative website, personalized services, precise and efficient logistics, flexible organization, but also the basic importance that is attributed to human factors and relationships with partners, make of Sinergroup Srl a reference for many companies of the market. A continuous and consistent effort, the ability to anticipate the evolution of the market demand and orientation to the understanding and satisfaction of our customers has always characterizes us in our work.
Born with the objective view in the exclusive distribution: Continue to be "Leader of the Brand Leader ", with activities and services of value. A choice of specialization that in recent years has allowed us to develop a unique knowledge and experience in the market. The thorough water treatment market understanding and high commercial performance, make us able to offer to our customers many products and services more personalized and appropriate to the individual end user. Our mission is to become your best business Partner!
The NDX is a 4–20 mA powered micro-controller based intelligent valve controller. The device contains a local user interface enabling configuration and operation without opening the device cover. Configuration and operation can also be made remotely by PC with asset management software connected to the control loop.
The document provides an overview of Siemens' miniature circuit breaker product range, including standard, high-capacity, universal current, high current, and power supply company product lines. It lists the technical specifications for each product line, including rated currents and voltages, tripping characteristics, terminals, approvals, and more. The benefits of the circuit breakers include high rated breaking capacity, excellent current limitation, different tripping characteristics, safety-compliant terminals, uniform additional components, and fast installation. The circuit breakers are designed to protect electrical equipment from overheating and leakage currents.
This document provides specifications and installation instructions for the HERZ-Motorised flow controller. The controller is a pressure independent balancing control valve (PIBCV) used to automatically maintain and balance flow rates in heating, cooling, and water systems. It works by measuring and adjusting to pressure variations to achieve the set flow rate. The document describes the device dimensions and technical specifications, materials, recommended installation procedures, accessories, and application examples.
The document provides information about the Liquiphant M Density and Density Computer FML621 for measuring the density of liquids. The system uses a Liquiphant M sensor with an electronic insert to measure density via pulse output. The Density Computer FML621 receives this input and can output the density measurement on current/pulse outputs. It also enables additional calculations and conversions of the density measurement. The document discusses the measuring principles, system design, inputs/outputs, installation, performance specifications, and accessories of the devices.
The Variable Area flowmeter is an instrument for metering the flowrate of liquids and gases in a pipeline. It includes a vertically oriented conical tube, whose diameter is larg- er at the top than at the bottom, through which the fluid flows upward and in which a vertically moving float is positioned.
Due to its full metal design, the SITRANS FVA250 variable area meter with a standard length of 250 mm (9.84 inch) can be used to measure many different types of liquids and gases passing through closed piping. The robust design means that it can also be used in harsh conditions. The various types of flange connec- tions, linings and float materials satisfy the requirements of the pharmaceutical and chemical industries.
The measured value is displayed directly on the scale with the standard version. For process monitoring and control, the device can be equipped with a transmitter (MEM) as well as limit switches.
World's first impact tool approved wireless torque transducer that can be used with any electric or air impact tools or in static mode to use with click or torque wrenches for final tightening and data collection
The document is a catalog for battery operated magnetic flow meters. It provides an overview of the RBEFB series battery powered electromagnetic flow meters, which are designed for water resource and industrial applications without power supply. The meters can achieve accuracy levels of 1.0%, 0.5% or 0.2% and feature micro-power design, lithium batteries with 3-6 year lifespan, LCD display, self-diagnostics, RS485 communication and optional GSM/GPRS remote monitoring software. The catalog describes the technical specifications, model selection guidelines, dimensions, display, measurement error curve and applications of the flow meters.
This document provides installation and operation instructions for a Gas turbine flowmeter Z100TB series. It includes:
- Technical specifications for the flowmeter such as measuring ranges, materials, accuracy levels, and process connections.
- Guidelines for proper installation including recommended mounting positions, required straight pipe lengths upstream and downstream, and special notices about filtration and draining air from the system.
- Cautions and warnings for safe operation including only using compatible fluids, following manufacturer safety precautions for hazardous gases, and annual calibration for best results.
This document provides installation and operation instructions for a Gas turbine flowmeter Z100TB series. It includes:
- Technical specifications for the flowmeter such as measuring ranges, materials, accuracy levels, and process connections.
- Guidelines for proper installation including recommended mounting positions, required straight pipe lengths upstream and downstream, and special notices about filtration and draining air from the system.
- Cautions and warnings for safe operation including only using compatible fluids, following manufacturer safety precautions for hazardous gases, and annual calibration for best results.
This manual will assist you in installing, using and maintaining your Zero Instrument flow meter. It is your responsibility to make sure that all operators have access to adequate instructions about safe operating and maintenance procedure.
This document provides an operation manual for the Vortex Flow Meter Model LUGB. It describes the product's general information including its description, operational principle, structure, technical data, and cautions for installation. The document also covers electrical wiring details for the different meter models and programming/setup instructions.
Parker manufactures one of the widest offerings of quick connect hose fittings available, with variants, options, and specialized products to suit almost every application.
This document provides installation and operation instructions for a Gas Turbine Flowmeter model ZERO100TB. It includes:
1. Technical specifications for the flowmeter, including measuring principles, design features, materials, flow ranges, accuracy ratings, and operating conditions.
2. Cautions and requirements for installation, including recommended mounting positions, minimum straight pipe lengths upstream and downstream, and special notices about foreign materials and draining air from the system.
3. Overviews of optional configurations for the flowmeter, including different converter models with displays, power options, outputs and communication protocols.
The T7500 series is but one of several variants available from Rotork Instruments for converting electric control signals of C voltage or current to pneumatic output.
The document provides information on the LM741 operational amplifier, including:
1. It describes the features and applications of the LM741 such as overload protection, no latch-up when exceeded common-mode range, and uses in comparators, filters, and DC amplifiers.
2. It provides the specifications for the LM741 including the absolute maximum ratings, recommended operating conditions, thermal information, and electrical characteristics over operating temperature ranges.
3. It details the pin configurations and functions of the 8-pin packages including inverting and non-inverting inputs, offset null pins, output, and power supply pins.
SOR manufactures a complete line of thermocouple elements, Resistance Temperature Detector (RTD) sensors, thermowells, industrial assemblies and specialty temperature sensors.
This document provides information about APM212 gear motors from Bucher Hydraulics, including both standard and low noise models. It discusses the components, technical specifications, applications, and improvements over previous models. The new APM212 motors offer benefits like higher efficiencies, ability to withstand high pressures, longer life, and lower noise/vibration compared to earlier models. Low noise versions utilize optimized gear profiles and materials to reduce pulsation by up to 75% compared to standard motors.
Apex Power Tools 2016 Gi 1250-eu-en0316 03Sean Ibrahim
The new catalogue GI-1250 shows the most important Industrial Power Tools of the brands Airetool, Apex, Dotco, Master Power, and Cleco. New Industrial Power Tools for Professionals.
The document provides an overview of industrial power tools from several brands, including Airetool, Apex, Dotco, Master Power, and Cleco. It describes various types of power tools such as tube rolling systems, tube expanders, sockets, drills, grinders, sanders, and assembly tools. The tools are intended for professional users and applications like manufacturing, maintenance, fastening, drilling, cutting, grinding, and finishing. Specifications and features are provided for each product line.
This document provides information on an electromagnetic water meter catalog from RB Flowmeter, including:
- An overview of the RBEFB-LS battery powered electromagnetic flow meter and its features such as long battery life, LCD display, IP68 protection, and remote monitoring software.
- The main technical parameters including measurement ranges, accuracy levels, materials, and communication interfaces.
- Details on model selection including pipe size, flange rating, materials, and configuration options.
- Dimensions, tables of specifications, descriptions of the display, interface, software system and applications for water supply, treatment and distribution networks.
In the field of industrial measurement and control, radar level meters are widely favored for their advantages of high accuracy and non-contact measurement. However, as a key component of this system – antenna, its performance directly affects the measurement effect of the whole level meter. Today, we will explore the knowledge of radar level meter antenna in depth, in order to better understand its working principle and application.
In the process of modern urban wastewater treatment, the fecal liquid receiving tank undertakes the task of collecting feces and organic waste in domestic sewage, which is an indispensable link in the wastewater treatment chain, and the special environmental conditions of the fecal liquid receiving tank bring challenges to the liquid level measurement.
In this paper, we will discuss the characteristics of fecal liquid receiving tank and analyze the application effect of radar level meter in liquid level monitoring through practical cases.
In the bakery industry, the management of ingredients is crucial. Accurately monitoring the stock level of bakery ingredients in small silos is of great significance to ensure production continuity and reduce waste.
In this paper, we will discuss the level characteristics of small silos for bakery ingredients, and combine them with an actual measurement case to illustrate the application effect of radar level meters.
Industrial measurement and control technology, radar level meter has become an indispensable tool for many industries with its advantages of high accuracy, high reliability and easy maintenance.
However, there are many brands of radar level meters on the market with different functions, how to make a wise choice among the complicated products? This article will provide you with a detailed brand selection guide to help you find the most suitable radar level meter for your needs.
In ship operation, ensuring accurate monitoring of fuel level in fuel tanks is extremely critical for safe navigation and energy efficiency management. Accurate measurement of fuel tank oil level can guarantee the stable oil supply of ship power system, and at the same time avoid oil spill accident and protect the marine environment.
Therefore, the choice of measurement technology for fuel tank oil level on ships is particularly important, and guided wave radar level meter is highly respected in this field for its high precision and high reliability.
In the process of industrial production, especially in the fields of petrochemical industry and mining industry, the sulfur pit is used as a facility for storing liquid sulfur, and the accurate measurement of its liquid level is of vital significance for guaranteeing production safety and environmental protection.
The characteristics of liquid sulfur in the sulfur pit and the environmental conditions put forward special requirements for the liquid level measurement technology, and the radar level meter, with its high accuracy and high reliability, shows a unique advantage in this field.
As an important base for energy conversion and supply, the operational efficiency and safety of power plants are of paramount importance. In the daily operation of power plants, level monitoring is a key link to ensure smooth production processes and prevent accidents.
As an advanced level measurement device, radar level meter is widely used in power plants because of its high accuracy, high reliability and adaptability. In this paper, we will discuss how to select and apply radar level meter in power plants.
In the petrochemical industry, the Amine Absorption Tower plays a vital role. It removes harmful carbon dioxide and other acid gases from industrial emissions by chemical absorption. The high viscosity and corrosive nature of the amine liquid makes monitoring and controlling the level of the amine liquid absorption tower particularly complex.
Therefore, the selection of a level measurement technology that is both accurate and reliable is essential to ensure the efficient operation of amine absorption towers. In this context, guided wave radar level meter is favored for its excellent performance.
In the field of industrial measurement, radar level meters are favored because of their high accuracy, reliability and wide range of applications. However, there are a wide variety of radar level meters on the market, and how to judge their quality has become a problem that users must face. Next, we will discuss the evaluation criteria of radar level meters from multiple dimensions.
First of all, accuracy is the primary indicator for measuring the performance of radar level meters. A high-quality radar level meter should have high-precision measurement capabilities and a very small error range. Therefore, when choosing, you should carefully check the product’s technical specifications to understand its accuracy parameters. Secondly, stability is also the key to judging the quality of radar level meters. In harsh industrial environments, external factors such as temperature, pressure, humidity, etc. may affect the stability of the equipment. High-quality radar level meters can maintain stable operation under a wide range of environmental conditions, such as operating normally in the temperature range of -40°C to +250°C, and are not easily affected by high pressure or steam. Furthermore, adaptability is a criterion that cannot be ignored when evaluating radar level meters. Excellent radar level meters can adapt to different media, including solids, liquids, slurries, etc.
In modern industrial and environmental protection projects, leachate wells are key facilities for treating wastewater produced in landfills. Accurate measurement of their liquid levels is of great significance for ensuring environmental safety and improving treatment efficiency.
Just as doctors use stethoscopes to accurately capture the rhythm of a heartbeat, engineers rely on radar level gauges to gain insight into changes in fluid levels in leachate wells. This article will conduct an in-depth analysis of the liquid level characteristics of leachate wells, and demonstrate the application value of radar level meters in this field through an actual measurement case.
Level measurement in cullet silos is a challenging task in industrial production. Due to the characteristics of cullet, such as irregular shape, fragility and reflectivity, it is not easy to accurately measure its material level in actual measurements.
This article will introduce the material level characteristics of cullet silos in detail, and analyze the application of radar level meters in cullet silo material level measurement based on actual cases.
The characteristics of the material level of the cullet silo mainly include the following aspects: Irregular material shape: The cullet shows an irregular shape, which causes the density and volume of the material accumulation to change greatly, making it difficult to measure the material level.
Materials with strong reflectivity: Broken glass has strong reflectivity and strong absorption and scattering effects on radar waves, which may cause severe attenuation of measurement signals and affect measurement accuracy. Poor material fluidity: Broken glass is easily stuck between pieces, resulting in poor fluidity and affecting the normal flow and emptying of materials.
Harsh measurement environment: Crushed glass silos are usually located in harsh environments such as high temperature, high humidity, and dust, which place high requirements on the durability and stability of measurement equipment.
As a non-contact measuring instrument, radar level gauge is widely used in liquid level measurement of various liquid storage tanks. However, during the actual installation process, some common misunderstandings may affect its measurement accuracy and stability. This article will discuss the installation misunderstandings of radar level gauges to help users better understand and avoid these problems.
The main building of a hydropower station is the core area of the hydropower station, where the measurement and control of liquid level are crucial to the stable operation of the hydropower station.
There are many instruments on the market that can be used to measure the liquid level in the main building of a hydropower station.
Radar level meter is one of them. It has been widely used in the liquid level measurement of the main building of a hydropower station.
Today we will introduce the application of radar level gauges in liquid level measurement in the main building of hydropower stations through two actual measurement cases.
In the ethanol production process, raw material silos are important facilities for storing raw materials for ethanol production, and accurate measurement of their material levels is of great significance to ensure production efficiency and product quality. As a high-precision measuring instrument, radar level meter is widely used in material level measurement in raw material silos of ethanol production.
This article will introduce the characteristics of ethanol production silos, and use a practical case to illustrate the application of radar level meters in the material level measurement of ethanol production raw material silos.
As a non-contact measuring instrument, radar level gauge has the characteristics of high measurement accuracy, good stability, and small impact on the measured medium. It is widely used in the measurement of various liquid levels.
However, in practical applications, radar level gauge distortion sometimes occurs, which brings great trouble to the measurement work. This article will introduce the causes and treatment methods of radar level gauge distortion.
It is common in industry to measure various non-electrical physical quantities, such as temperature, pressure, speed, angle, etc., which need to be converted into analog electrical signals before they can be transmitted to a control room or display device hundreds of meters away.
This device that converts physical quantities into electrical signals is called a transmitter. The most widely used in industry is to use 4~20mA current to transmit analog quantities.
As a non-contact measuring instrument, radar level gauge has been widely used in industrial applications. However, in actual use, radar level gauges may be affected by various interference factors, resulting in inaccurate measurement results.
In order to ensure the measurement accuracy and stability of the radar level gauge, eliminating interference has become a problem that must be faced.
As a renewable energy source, the liquid level measurement of biogas digesters has been put to the test. As we all know, in the industrial field, the application of radar level gauges is becoming more and more common.
So, can the radar level meter be used to measure small biogas pools? This article will discuss the principle, measurement range, error analysis and other aspects of the radar level meter.
In the ever-evolving landscape of industrial instrumentation, Coriolis mass flow meters have emerged as pivotal devices, revolutionizing the measurement and control of fluid flows across various sectors. As global industries strive for enhanced accuracy, efficiency, and sustainability, the demand for advanced flow measurement technologies has surged. Coriolis mass flow meters, with their ability to provide precise and real-time measurements of mass flow, density, and temperature, have become indispensable tools in optimizing processes and ensuring compliance with rigorous industry standards.
This article delves into the dynamic and rapidly evolving global market trends surrounding Coriolis mass flow meter technology. From oil and gas to pharmaceuticals, food and beverage to chemicals, the application of Coriolis meters spans diverse sectors, underscoring their versatility. With ongoing technological advancements pushing the boundaries of precision and reliability, stakeholders in these industries are progressively incorporating Coriolis mass flow meters into their operations. This integration fosters innovation and propels the next phase of industrial evolution.
Radar level meter, as an advanced measuring equipment, has been widely used in many industries due to its high accuracy and high stability. Especially in the key field of offshore oil and gas exploration, the role of radar level gauges is even more indispensable. This article will discuss the application value of radar level meters in the offshore oil and gas exploration industry.
More from Dalian Zero Instrument Technology Co., Ltd China (20)
How MJ Global Leads the Packaging Industry.pdfMJ Global
MJ Global's success in staying ahead of the curve in the packaging industry is a testament to its dedication to innovation, sustainability, and customer-centricity. By embracing technological advancements, leading in eco-friendly solutions, collaborating with industry leaders, and adapting to evolving consumer preferences, MJ Global continues to set new standards in the packaging sector.
[To download this presentation, visit:
https://www.oeconsulting.com.sg/training-presentations]
This PowerPoint compilation offers a comprehensive overview of 20 leading innovation management frameworks and methodologies, selected for their broad applicability across various industries and organizational contexts. These frameworks are valuable resources for a wide range of users, including business professionals, educators, and consultants.
Each framework is presented with visually engaging diagrams and templates, ensuring the content is both informative and appealing. While this compilation is thorough, please note that the slides are intended as supplementary resources and may not be sufficient for standalone instructional purposes.
This compilation is ideal for anyone looking to enhance their understanding of innovation management and drive meaningful change within their organization. Whether you aim to improve product development processes, enhance customer experiences, or drive digital transformation, these frameworks offer valuable insights and tools to help you achieve your goals.
INCLUDED FRAMEWORKS/MODELS:
1. Stanford’s Design Thinking
2. IDEO’s Human-Centered Design
3. Strategyzer’s Business Model Innovation
4. Lean Startup Methodology
5. Agile Innovation Framework
6. Doblin’s Ten Types of Innovation
7. McKinsey’s Three Horizons of Growth
8. Customer Journey Map
9. Christensen’s Disruptive Innovation Theory
10. Blue Ocean Strategy
11. Strategyn’s Jobs-To-Be-Done (JTBD) Framework with Job Map
12. Design Sprint Framework
13. The Double Diamond
14. Lean Six Sigma DMAIC
15. TRIZ Problem-Solving Framework
16. Edward de Bono’s Six Thinking Hats
17. Stage-Gate Model
18. Toyota’s Six Steps of Kaizen
19. Microsoft’s Digital Transformation Framework
20. Design for Six Sigma (DFSS)
To download this presentation, visit:
https://www.oeconsulting.com.sg/training-presentations
SATTA MATKA SATTA FAST RESULT KALYAN TOP MATKA RESULT KALYAN SATTA MATKA FAST RESULT MILAN RATAN RAJDHANI MAIN BAZAR MATKA FAST TIPS RESULT MATKA CHART JODI CHART PANEL CHART FREE FIX GAME SATTAMATKA ! MATKA MOBI SATTA 143 spboss.in TOP NO1 RESULT FULL RATE MATKA ONLINE GAME PLAY BY APP SPBOSS
[To download this presentation, visit:
https://www.oeconsulting.com.sg/training-presentations]
This presentation is a curated compilation of PowerPoint diagrams and templates designed to illustrate 20 different digital transformation frameworks and models. These frameworks are based on recent industry trends and best practices, ensuring that the content remains relevant and up-to-date.
Key highlights include Microsoft's Digital Transformation Framework, which focuses on driving innovation and efficiency, and McKinsey's Ten Guiding Principles, which provide strategic insights for successful digital transformation. Additionally, Forrester's framework emphasizes enhancing customer experiences and modernizing IT infrastructure, while IDC's MaturityScape helps assess and develop organizational digital maturity. MIT's framework explores cutting-edge strategies for achieving digital success.
These materials are perfect for enhancing your business or classroom presentations, offering visual aids to supplement your insights. Please note that while comprehensive, these slides are intended as supplementary resources and may not be complete for standalone instructional purposes.
Frameworks/Models included:
Microsoft’s Digital Transformation Framework
McKinsey’s Ten Guiding Principles of Digital Transformation
Forrester’s Digital Transformation Framework
IDC’s Digital Transformation MaturityScape
MIT’s Digital Transformation Framework
Gartner’s Digital Transformation Framework
Accenture’s Digital Strategy & Enterprise Frameworks
Deloitte’s Digital Industrial Transformation Framework
Capgemini’s Digital Transformation Framework
PwC’s Digital Transformation Framework
Cisco’s Digital Transformation Framework
Cognizant’s Digital Transformation Framework
DXC Technology’s Digital Transformation Framework
The BCG Strategy Palette
McKinsey’s Digital Transformation Framework
Digital Transformation Compass
Four Levels of Digital Maturity
Design Thinking Framework
Business Model Canvas
Customer Journey Map
NIMA2024 | De toegevoegde waarde van DEI en ESG in campagnes | Nathalie Lam |...BBPMedia1
Nathalie zal delen hoe DEI en ESG een fundamentele rol kunnen spelen in je merkstrategie en je de juiste aansluiting kan creëren met je doelgroep. Door middel van voorbeelden en simpele handvatten toont ze hoe dit in jouw organisatie toegepast kan worden.
Industrial Tech SW: Category Renewal and CreationChristian Dahlen
Every industrial revolution has created a new set of categories and a new set of players.
Multiple new technologies have emerged, but Samsara and C3.ai are only two companies which have gone public so far.
Manufacturing startups constitute the largest pipeline share of unicorns and IPO candidates in the SF Bay Area, and software startups dominate in Germany.
Storytelling is an incredibly valuable tool to share data and information. To get the most impact from stories there are a number of key ingredients. These are based on science and human nature. Using these elements in a story you can deliver information impactfully, ensure action and drive change.
Top mailing list providers in the USA.pptxJeremyPeirce1
Discover the top mailing list providers in the USA, offering targeted lists, segmentation, and analytics to optimize your marketing campaigns and drive engagement.
The Genesis of BriansClub.cm Famous Dark WEb PlatformSabaaSudozai
BriansClub.cm, a famous platform on the dark web, has become one of the most infamous carding marketplaces, specializing in the sale of stolen credit card data.
Best practices for project execution and deliveryCLIVE MINCHIN
A select set of project management best practices to keep your project on-track, on-cost and aligned to scope. Many firms have don't have the necessary skills, diligence, methods and oversight of their projects; this leads to slippage, higher costs and longer timeframes. Often firms have a history of projects that simply failed to move the needle. These best practices will help your firm avoid these pitfalls but they require fortitude to apply.
Zodiac Signs and Food Preferences_ What Your Sign Says About Your Tastemy Pandit
Know what your zodiac sign says about your taste in food! Explore how the 12 zodiac signs influence your culinary preferences with insights from MyPandit. Dive into astrology and flavors!
Starting a business is like embarking on an unpredictable adventure. It’s a journey filled with highs and lows, victories and defeats. But what if I told you that those setbacks and failures could be the very stepping stones that lead you to fortune? Let’s explore how resilience, adaptability, and strategic thinking can transform adversity into opportunity.
IMPACT Silver is a pure silver zinc producer with over $260 million in revenue since 2008 and a large 100% owned 210km Mexico land package - 2024 catalysts includes new 14% grade zinc Plomosas mine and 20,000m of fully funded exploration drilling.
Unveiling the Dynamic Personalities, Key Dates, and Horoscope Insights: Gemin...my Pandit
Explore the fascinating world of the Gemini Zodiac Sign. Discover the unique personality traits, key dates, and horoscope insights of Gemini individuals. Learn how their sociable, communicative nature and boundless curiosity make them the dynamic explorers of the zodiac. Dive into the duality of the Gemini sign and understand their intellectual and adventurous spirit.
3. 2
1. General Information
This manual will assist you in installing, using and maintaining your flow meter. It is your responsibility to
make sure that all operators have access to adequate instructions about safe operating and maintenance
procedure.
Warning
For your safety, review the major warnings and cautions below before operating your equipment.
1. Use only fluids that are compatible with the
housing material and wetted components of your
vortex flowmeter.
2. When measuring flammable liquids, observe
precautions against fire or explosion.
3. When handling hazardous liquids, always follow
the liquid manufacturer’s safety precautions.
4. When working in hazardous environments,
always exercise appropriate safety precautions.
5. During vortex flowmeter removal, liquid may
spill. Follow the liquid manufacturer’s safety
precautions for clean up of minor spills.
6. Handle the sensor carefully. Even small
scratches or nicks can affect accuracy.
7. When tightening the vortex, use a wrench only
on the wrench flats.
8. For best results, calibrate the meter at least 1
time per year.
1.1 Product Description
series Vortex flow meters are designed for measuring the volume/mass flow of liquids, gases and
steam based on Karman vortex principle.
Adopting advanced differential algorithm along with measurement of isolation, shielding and wave filtering,
series vortex flow meters have the advantages of immunity on vibration and noise. Meanwhile, the
liabilities of series vortex flow meters are well guaranteed by unique sensor packaging technology.
Upon receipt, examine your meter for visible damage. The vortex flowmeter is a precision measuring
instrument and should be handled carefully. Remove the protective plugs and caps for a thorough
inspection. If any items are damaged or missing, contact us.
Make sure the vortex flow model meets your specific needs. For your future reference, it might be useful
to record this information on nameplate in the manual in case it becomes unreadable on the vortex
flowmeter. Refer to the nameplate for your customized product’s specification.
Z100VX
Z100VX
Z100VX
4. 3
2. Technical Data
Measuring system
Application range (1) Gas; (2) Liquid; (3) Steam
Measured Value
Primary measured value Flow Rate
Secondary measured value
Volume flow ; (Pressure and Temperature is
available for model with compensation)
Design
Features
Modular construction The measurement system consists of a flow
sensor and a signal converter. It is available as
compact and as separate version.
Compact version converter N Type: Pulse output without local display
A Type: 4‐20mA Output without local display
B Type: Local Display; Lithium Battery Power;
No Output (Battery Part No.: ER26500)
C Type: Local Display; 24V DC Power; 4‐20mA
Output;
Optional Function:
(1) Backup Power Supply: Lithium Battery
(2) Modbus RS485
(3) Pulse Output
Connection
Flange: DN15‐DN300
Wafer: DN15‐DN300
Measurement Ratio Standard – 10:1
Measuring accuracy
Flow conditions similar to EN 29104
Medium: Water / Gas
Electrical conductivity: ≥ 300 μS/cm
Temperature: +10...+30°C / +50...+86°F
Inlet section: ≥ 10 DN
Reference conditions
Operating pressure: 1 bar / 14.5 psig
Flow Meter Accuracy
For Liquid: 1.0% of rate
For Gas and Steam: 1.5% of rate
P.s.: D type is Temperature and Pressure Compensation type,or temperature compensation only, If need please notice before quote.
6. 5
Materials
Sensor housing SS304
Other materials on request
Flanges SS304
Other materials on request
Converter Housing
Standard: polyurethane coated die‐cast
aluminum
Process connections
Flange
EN 1092‐1 DN15...300 in PN 6...25
ASME 1/2”…12" in 150 lb RF
JIS 1/2”…12” in 10...20K
Design of gasket surface RF
Other sizes or pressure ratings on request
Wafer DN15…DN300
Measurable Flow Rate Range:
Note: The flow range as blow is for reference only. Consult the factory if you have special requirement.
Refer to the nameplate or certificate for actual flow range.
Nominal
Diameter
Liquid Gas
(mm) (in.) Flow (m3/h) Flow (m3/h)
15 1/2” 1.2 to 6.2 5 to 25
20 3/4” 1.5 to 10 8 to 50
25 1” 1.6 to 16 10 to 70
40 1‐1/2” 2.5 to 25 22 to 220
50 2” 3.5 to 35 36 to 320
65 2‐1/2” 6.5 to 65 50 to 480
80 3” 10 to 100 70 to 640
100 4” 15 to 150 130 to 1100
125 5” 25 to 250 200 to 1700
150 6” 36 to 380 280 to 2240
200 8” 62 to 650 580 to 4960
250 10” 140 to 1400 970 to 8000
300 12” 200 to 2000 1380 to 11000
7. 6
3. Model and Selection
Description
Flange
Connection
Wafer
Gas
Liquid Fluid
Steam
Diameter
Three Digitals; for example:
010: 10 mm; 015: 15 mm;
080: 80 mm; 100: 100 mm
Compact Type
Structure
Remote Type
No display; 24V DC; Pulse Output
No display; 24V DC; 4‐20mA Output
Local display; Lithium Battery Power; No
output
Local display; 24V DC Power; 4‐20mA
Output;
Optional backup power: Lithium Battery
Local display; 24V DC Power; 4‐20mA
Output; Modbus RS485 Communication
Optional backup power: Lithium Battery
Converter
Local display; 24V DC Power; 4‐20mA
Output; Modbus RS485 Communication
Temperature and Pressure Compensation
Refer to the photo on cover (Right One)
Safety Field without Explosion
Explosion Rating
ExdIIBT6
DXX: D06, D10, D16, D25, D40
D06: DIN PN6; D10: DIN PN10
D16: DIN PN16; D25: DIN PN25
D40: DIN PN40
ANSI 150#; ANSI 300#
ANSI 600#
Flange Standard
Wafer Connection; Mating Flange included.
‐20...+70°C
‐20...+250°C Fluid Temperature
‐20...+350°C
Z100VX
8. 7
4. Cautions for Installation
4.1 Mounting Positions
• Pipes must be fully filled with liquids. It is essential that pipes remain fully filled at all times,
otherwise flow rate indications may be affected and measurement errors may be caused.
• Avoid Air Bubbles. If air bubbles enter a measurement pipe, flow rate indications may be affected
and measurement errors may be caused.
• Avoid all pipe locations where the flow is pulsating, such as in the outlet side of piston or
diaphragm pumps.
• Avoid locations near equipment producing electrical interference such as electric motors,
transformers, variable frequency, etc.
• Install the meter with enough room for future access for maintenance purposes.
Warning: Precaution for direct sunshine and rain when the meter is installed outside.
16. 15
6. Programming and Setup
: All flowmeters are tested and calibrated prior to leaving the factory, and the unique
K‐factor is provided on the calibration certificate. Keep the calibration certificate well to
avoid the loss of K‐factor.
6.1 No display; Pulse Output
Customer should set the correct K‐factor into PLC or Flow totalizer in order to get the correct flow rate.
6.2 No display; 4‐20mA Output
Only perform the Zero Point Calibration where it’s necessary.
6.2.1 Zero Point Calibration
(1) Shut off the value where the flowmeter is installed, ensure there is no flow rate in pipe.
(2) Put high accuracy amperometer into the circuit loop as series connection.
(3) Adjust the potentiometer W502 to make sure the display on amperometer is 4mA.
6.2.2 Full Scale Calibration: it’s ONLY available for factory; return the flowmeter to factory for full scale
calibration where is applicable.
6.3 Local Display
Note: all menus are present in all signal converter versions, but some parameter settings are ONLY valid for
specified models.
6.3.1 Display and Keys
① Flow Rate
② Total Flow
③ Keys (See table below for function and representation in text)
17. 16
Key Measuring mode Menu mode Sub‐menu or function
mode
Parameter and data
mode
Enter 1. Display the frequency
corresponding to flow
rate
2. Enter the parameter
setting mode
Select menu Press 1 time, return
to menu mode, data
saved
Save the value and
advance to next menu
‐ ‐ ‐ For numerical values,
move cursor one
position to the right
or left
‐ ‐ Select sub‐menu or
function
Use cursor
highlighted to change
number, unit, setting
Esc ‐ Return to measuring
mode but prompt
whether the data
should be saved
Return to measuring
mode but prompt
whether the data
should be saved
Return to measuring
mode but prompt
whether the data
should be saved
Note: Data are not saved when press “Esc” to return to measuring mode. If the value need to be changed, press
“Enter” to save value first
6.3.2 Parameters Set
Press “Enter” two times at measuring mode, it leads to Password Menu “‐ ‐ ‐ ‐“.
(1) Input correct password and press “Enter” can start parameter setting.
(2) Press “Enter” again and no password is input can ONLY view all parameters
The total menus in “Parameters Set” are 16, and users can access and modify these menus depending on
the input password grade. See table below for more information on password grade.
Table. Description of Password Grade
Password Grade Password Login Privileges
Grade 1
No Password
Requirement
Read Only
Grade 2 1234 Read and Edit
Grade 3 5678
Save all data as
factory defaults
Grade 4 1111
Reload factory
defaults
Note: parameter setting can be ONLY performed by authorized engineer, as parameter change can affect
the accuracy of the flowmeter.
18. 17
Specific Menu – Parameters Set
Menu Parameter Name Setting Method Grades Range
F‐‐‐01 Flow Rate Unit Select Parameter
Factory
ONLY
1; 2; 3
F‐‐‐02
Scaled Pulse Output
In Liters
Select Parameter User
1: 1 Liter/Pulse
10: 10 Liter/Pulse
100: 100 Liter/Pulse
F‐‐‐03 Damping Time Input Value User
Unit: Second
Value: 1‐10
F‐‐‐04 Maximum Flow Rate Input Value User Unit: same as Flow Rate
F‐‐‐05 Minimum Flow Rate Input Value User Unit: same as Flow Rate
F‐‐‐06
Maximum Frequency
Output
Input Value User
0‐3000 Hz
Accuracy: 0.1Hz
F‐‐‐07 Baud Rate Select Parameter User
1200; 2400; 4800; 9600;
19200
Data Format: n; 8; 1
F‐‐‐08 Device Address Input Value User 01‐99
F‐‐‐09
Frequency Output
Mode
Select Parameter User 1; 2
F‐‐‐10
Total Flow
Reset
Input Value User
Reset the new value and
press “Enter” to confirm
the change promptly.
P1
Linearization of the
Flowcurve: point 1
Input Value
Factory
ONLY
First Row: Frequency (P1)
Second Row: K‐Factor (P1)
P2
Linearization of the
Flowcurve: point 2
Input Value
Factory
ONLY
First Row: Frequency (P2)
Second Row: K‐Factor (P2)
P3
Linearization of the
Flowcurve: point 3
Input Value
Factory
ONLY
First Row: Frequency (P3)
Second Row: K‐Factor (P3)
P4
Linearization of the
Flowcurve: point 4
Input Value
Factory
ONLY
First Row: Frequency (P4)
Second Row: K‐Factor (P4)
P5
Linearization of the
Flowcurve: point 5
Input Value
Factory
ONLY
First Row: Frequency (P5)
Second Row: K‐Factor (P5)
P Average Input Value
Factory
ONLY
First Row: Frequency (P)
Second Row: K‐Factor (P)
6.3.3 Parameter Function Table
19. 18
No. Function Settings / descriptions
F‐‐‐01 Flow Rate Unit
Selectable: 1, 2, 3
1: m3; 2: Liter; 3. Factory Reserved
Consult the factory first to change the unit, as the K‐factor should also be
changed.
F‐‐‐02
Scaled Pulse
Output In Liters
Selectable: 1, 10, 100
1: 1 liter/Pulse; 10: 10 Liters/Pulse; 100: 100 Liters/Pulse
Only valid for model supporting Pulse Output; and Position 3 of DIP
Switch is ON, others two are OFF.
F‐‐‐03 Damping Time Value: 1‐10 second; Recommended Value: 4 Second
Flow Range
F‐‐‐04
Maximum Flow
Rate
Unit: same as Flow Rate
F‐‐‐05
Minimum Flow
Rate
Unit: same as Flow Rate
Frequency Output
F‐‐‐06
Maximum
Frequency
Output
Value: 0‐3000 Hz
Accuracy: 0.1Hz
RS485 Communication
Selectable: 1200; 2400; 4800; 9600; 19200 (Unit: Hz)
F‐‐‐07 Baud Rate
Default Data Format: 9600, n, 8, 1
F‐‐‐08 Device Address Value: 01‐99
Selectable: 1, 2
F‐‐‐09
Frequency Output
Mode 1: Original Pulse Output without linearization
2: Corrected Pulse Output after linearization
Reset Total Flow
F‐‐‐10
Total Flow
Reset
Reset the new value and press “Enter” to confirm the change promptly.
Linearization
P1
Linearization of the
Flowcurve: point 1
First Row: Frequency (P1)
Second Row: K‐Factor (P1)
P2
Linearization of the
Flowcurve: point 2
First Row: Frequency (P2)
Second Row: K‐Factor (P2)
P3
Linearization of the
Flowcurve: point 3
First Row: Frequency (P3)
Second Row: K‐Factor (P3)
P4
Linearization of the
Flowcurve: point 4
First Row: Frequency (P4)
Second Row: K‐Factor (P4)
P5
Linearization of the
Flowcurve: point 5
First Row: Frequency (P5)
Second Row: K‐Factor (P5)
P Average K‐Factor
First Row: Frequency (P)