B
15
15
15
15
C
30
40
40
40
D
64
84
89
95
E
22
22
22
22
F
4.5
6
6
6
G
0
0
0
0
R
180°
180°
180°
180°
weight (kg)
0.15
0.25
0.3
0.4
- The document provides specifications for series DU and SCDU explosionproof operators for use in potentially explosive atmospheres.
- The operators comply with ATEX Directive 94/9/EC and have
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Hazardous Area Enclosures:
Zone 1 & Zone 2 (Gases)
Zone 21 & Zone 22 (Dusts)
Hazardous Area Classification
Group: II Category: 2G - 2D
Hazardous Area Enclosure Approvals
ATEX
II 2 G Ex db IIB+H2 T6...T3
II 2 G Ex db [ia/ib] IIB+H2 T6...T3
II 2 D Ex tb IIIC T85ºC...T150ºC
IECEx
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
INMETRO
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
GOST-R GOST-K
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
Ex tD A21 T85ºC...T150ºC
1 Ex d IIB+H2 U
NEC505
USL: Class 1, Zone 1, AEx db IIB+H2
Zone 21 AEx tb IIIC T85ºC...T150ºC
CNL: Exd IIB+H2; Class II, Groups E, F and G
FEAM EJB INX Enclosures - Mechanical Features
Stainless steel AISI-316 L body/cover
Stainless steel AISI-316 L screws
Stainless steel AISI-316 L/aluminium internal mounting plate
Stainless steel AISI-316 L fixing lugs - stainless steel stirrups sp.10mm (EJB71/73 and EJB91/93)
Hinges welded on cover and body
Opening handle - insulating material fixed on cover by stainless steel screws
T&D are distributors for the FEAM range of Hazardous Area Lighting for installation in potentially explosive atmospheres - FEAM lighting is specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
Feam EJB INX Zone 1 & Zone 2 Enclosures (Atex) Hazardous Area
Hazardous Area Enclosures:
Zone 1 & Zone 2 (Gases)
Zone 21 & Zone 22 (Dusts)
Hazardous Area Classification
Group: II Category: 2G - 2D
Hazardous Area Enclosure Approvals
ATEX
II 2 G Ex db IIB+H2 T6...T3
II 2 G Ex db [ia/ib] IIB+H2 T6...T3
II 2 D Ex tb IIIC T85ºC...T150ºC
IECEx
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
INMETRO
Ex db IIB+H2 T6...T3
Ex db [ia/ib] IIB+H2 T6...T3
Ex tb IIIC T85ºC...T150ºC
GOST-R GOST-K
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
Ex tD A21 T85ºC...T150ºC
1 Ex d IIB+H2 U
NEC505
USL: Class 1, Zone 1, AEx db IIB+H2
Zone 21 AEx tb IIIC T85ºC...T150ºC
CNL: Exd IIB+H2; Class II, Groups E, F and G
FEAM EJB INX Enclosures - Mechanical Features
Stainless steel AISI-316 L body/cover
Stainless steel AISI-316 L screws
Stainless steel AISI-316 L/aluminium internal mounting plate
Stainless steel AISI-316 L fixing lugs - stainless steel stirrups sp.10mm (EJB71/73 and EJB91/93)
Hinges welded on cover and body
Opening handle - insulating material fixed on cover by stainless steel screws
T&D are distributors for the FEAM range of Hazardous Area Lighting for installation in potentially explosive atmospheres - FEAM lighting is specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
ASCO Solenoid Valves Catalog with detailed specifications to order with complete correct sizes and configuration choices. For reference only. To order, contact Carotek.com
FEAM enclosures are suitable for Hazardous Area Enclosures Zone 1 & Zone 2. T&D are distributors for the FEAM range of Hazardous Area Enclosures for installation in potentially explosive atmospheres - FEAM enclosures are specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
ATEX, IECEx, Inmetro, GOST-R, GOST-K, NEC505 Certified Enclosures.
Hazardous Area Enclosures : Zone 1 & Zone 2 (Gases) - Zone 21 & Zone 22 (Dusts).
Hazardous Area Classification
Group: II Category: 2G - 2D
The AW-901eR & AW-903eR single-wafer dry etchers are automated tools designed as a flexible 13.56MHz RF Parallel Plate plasma etching systems for high-volume wafer fabrication. AW-901eR & AW-903eR are in direct response to manufacturer’s concerns for wafer breakage, Uniformity, Uptime, Reliability, and Production-Proven technology
Converting from one signal type to another is a common challenge in process control. When the application calls for conversion from an electrical signal, current or voltage, to a pneumatic signal (pressure), this calls for an I/P or E/P transducer.
Về chúng tôi
Số 141 đường Phú Châu, Kp. 1, P. Tam Bình, Q. Thủ Đức, Tp. Hồ Chí Minh
ĐT: (028) 3636 5671|2|3
Hotline: 0909 41 61 43
Email: contact@beeteco.com
Siemens,
Catalog Thiết Bị Điện Siemens, Catalog Thiết Bị Điện,
Catalog Phụ Kiện Siemens, Catalog Phụ Kiện,
Catalog Siemens, Catalog,
http://dienhathe.com,
Chi tiết các sản phẩm khác của Siemens tại https://dienhathe.com
Xem thêm các Catalog khác của Siemens tại https://dienhathe.info
Để nhận báo giá sản phẩm Siemens vui lòng gọi: 0907.764.966
Flameproof Pressure Switches are designed as per IS2148 for Gas Gr. IIC Flameproof - CE Certification and approved by a leading European Lab – “BASEEFA” for ATEX & ICEEX certificates
Various Ranges : from 0 to 150 mm Wc upto 0 to 400 Bar
Differential (Dead Band) : Fixed (Within 10% of set value) Or, Adjustable
Sensing Element : Diaphragm (PTFE, Neoprene or, SS 316) or Piston
Enclosure : Flameproof to group IIC
Rugged, NEMA 4X, epoxy coated enclosure
SPDT or DPDT switch output
Easy access wiring
Single switch output
Internal reference scale and adjustable deadband available
Adjustable ranges: ◦30 "Hg Vac to 5000 psi
• 1 bar Vac to 344 bar
• 0.2 "wcd to 500 psid
• 0,5 mbar d to 34,5 bar d
• -180 to 650 ºF
• -117 to 340ºC
Approvals: UL, CSA, CE, TUV
Due to its full metal design, the SITRANS FVA250 variable area meter with a standard length of 250 mm (9.84 inch) can be used to measure many different types of liquids and gases passing through closed piping. The robust design means that it can also be used in harsh conditions. The various types of flange connec- tions, linings and float materials satisfy the requirements of the pharmaceutical and chemical industries.
The measured value is displayed directly on the scale with the standard version. For process monitoring and control, the device can be equipped with a transmitter (MEM) as well as limit switches.
Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019CTY TNHH HẠO PHƯƠNG
Công ty Cổ phần Hạo Phương xin gửi đến Quý khách hàng Catalog MCCB & ACB Fuji Electric Mới Nhất (2019) gồm
MCCB (Molded case circuit breakers ) dòng G-TWIN
ACB (Air circuit breakers) dòng DH
Quý khách có nhu cầu mua hàng hoặc hợp tác cùng chúng tôi xin vui lòng liên hệ theo địa chỉ :
CÔNG TY CỔ PHẦN HẠO PHƯƠNG
Trụ sở chính:
Địa chỉ: Số 88 đường Vĩnh Phú 40, Kp. Hòa Long, P. Vĩnh Phú, Thuận An, Bình Dương.
Văn phòng Hà Nội:
Địa chỉ: Số 95 TT4 – KĐT Mỹ Đình Sông Đà – Phường Mỹ Đình – Q. Nam Từ Liêm – Hà Nội
Chi nhánh Cambodia:
Địa chỉ: The Park Land SenSok, Borey Chip Mong, House Number 22, P11.Sangkat Phnom Penh Thmey, Khan San Sok, Phnom Penh.
Email: cs@haophuong.com – Website: haophuong.com
Facebook: https://www.facebook.com/haophuongcompany/
HOTLINE: 1800 6547
200 Series Interface A Nexans Euromold Cable Connectors and Bushings connect and terminate HV cables to Interface A bushings on switchgear and transformers.
Nexans Euromold provide high voltage cable accessories to suit the 7 main bushing interfaces : A, B, C (Compact), C (Symmetrical), D, E and F.
Nexans Euromold cable joints, cable terminations, epoxy bushings, angled (elbow) and straight plug-in or bolted separable connectors for connecting, jointing and terminating high voltage cables.
ASCO Solenoid Valves Catalog with detailed specifications to order with complete correct sizes and configuration choices. For reference only. To order, contact Carotek.com
FEAM enclosures are suitable for Hazardous Area Enclosures Zone 1 & Zone 2. T&D are distributors for the FEAM range of Hazardous Area Enclosures for installation in potentially explosive atmospheres - FEAM enclosures are specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
ATEX, IECEx, Inmetro, GOST-R, GOST-K, NEC505 Certified Enclosures.
Hazardous Area Enclosures : Zone 1 & Zone 2 (Gases) - Zone 21 & Zone 22 (Dusts).
Hazardous Area Classification
Group: II Category: 2G - 2D
The AW-901eR & AW-903eR single-wafer dry etchers are automated tools designed as a flexible 13.56MHz RF Parallel Plate plasma etching systems for high-volume wafer fabrication. AW-901eR & AW-903eR are in direct response to manufacturer’s concerns for wafer breakage, Uniformity, Uptime, Reliability, and Production-Proven technology
Converting from one signal type to another is a common challenge in process control. When the application calls for conversion from an electrical signal, current or voltage, to a pneumatic signal (pressure), this calls for an I/P or E/P transducer.
Về chúng tôi
Số 141 đường Phú Châu, Kp. 1, P. Tam Bình, Q. Thủ Đức, Tp. Hồ Chí Minh
ĐT: (028) 3636 5671|2|3
Hotline: 0909 41 61 43
Email: contact@beeteco.com
Siemens,
Catalog Thiết Bị Điện Siemens, Catalog Thiết Bị Điện,
Catalog Phụ Kiện Siemens, Catalog Phụ Kiện,
Catalog Siemens, Catalog,
http://dienhathe.com,
Chi tiết các sản phẩm khác của Siemens tại https://dienhathe.com
Xem thêm các Catalog khác của Siemens tại https://dienhathe.info
Để nhận báo giá sản phẩm Siemens vui lòng gọi: 0907.764.966
Flameproof Pressure Switches are designed as per IS2148 for Gas Gr. IIC Flameproof - CE Certification and approved by a leading European Lab – “BASEEFA” for ATEX & ICEEX certificates
Various Ranges : from 0 to 150 mm Wc upto 0 to 400 Bar
Differential (Dead Band) : Fixed (Within 10% of set value) Or, Adjustable
Sensing Element : Diaphragm (PTFE, Neoprene or, SS 316) or Piston
Enclosure : Flameproof to group IIC
Rugged, NEMA 4X, epoxy coated enclosure
SPDT or DPDT switch output
Easy access wiring
Single switch output
Internal reference scale and adjustable deadband available
Adjustable ranges: ◦30 "Hg Vac to 5000 psi
• 1 bar Vac to 344 bar
• 0.2 "wcd to 500 psid
• 0,5 mbar d to 34,5 bar d
• -180 to 650 ºF
• -117 to 340ºC
Approvals: UL, CSA, CE, TUV
Due to its full metal design, the SITRANS FVA250 variable area meter with a standard length of 250 mm (9.84 inch) can be used to measure many different types of liquids and gases passing through closed piping. The robust design means that it can also be used in harsh conditions. The various types of flange connec- tions, linings and float materials satisfy the requirements of the pharmaceutical and chemical industries.
The measured value is displayed directly on the scale with the standard version. For process monitoring and control, the device can be equipped with a transmitter (MEM) as well as limit switches.
Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019CTY TNHH HẠO PHƯƠNG
Công ty Cổ phần Hạo Phương xin gửi đến Quý khách hàng Catalog MCCB & ACB Fuji Electric Mới Nhất (2019) gồm
MCCB (Molded case circuit breakers ) dòng G-TWIN
ACB (Air circuit breakers) dòng DH
Quý khách có nhu cầu mua hàng hoặc hợp tác cùng chúng tôi xin vui lòng liên hệ theo địa chỉ :
CÔNG TY CỔ PHẦN HẠO PHƯƠNG
Trụ sở chính:
Địa chỉ: Số 88 đường Vĩnh Phú 40, Kp. Hòa Long, P. Vĩnh Phú, Thuận An, Bình Dương.
Văn phòng Hà Nội:
Địa chỉ: Số 95 TT4 – KĐT Mỹ Đình Sông Đà – Phường Mỹ Đình – Q. Nam Từ Liêm – Hà Nội
Chi nhánh Cambodia:
Địa chỉ: The Park Land SenSok, Borey Chip Mong, House Number 22, P11.Sangkat Phnom Penh Thmey, Khan San Sok, Phnom Penh.
Email: cs@haophuong.com – Website: haophuong.com
Facebook: https://www.facebook.com/haophuongcompany/
HOTLINE: 1800 6547
200 Series Interface A Nexans Euromold Cable Connectors and Bushings connect and terminate HV cables to Interface A bushings on switchgear and transformers.
Nexans Euromold provide high voltage cable accessories to suit the 7 main bushing interfaces : A, B, C (Compact), C (Symmetrical), D, E and F.
Nexans Euromold cable joints, cable terminations, epoxy bushings, angled (elbow) and straight plug-in or bolted separable connectors for connecting, jointing and terminating high voltage cables.
Idec catalog switching power supplies ep1196 0ps5r-sallslimDien Ha The
Idec catalog switching power supplies ep1196 0ps5r-sallslim
Catalog Idec, Catalog,
Catalog Thiết Bị Điện Idec, Catalog Thiết Bị Điện,
Catalog Điện Công Nghiệp Idec, Catalog Điện Công Nghiệp,
http://dienhathe.com,
Chi tiết các sản phẩm khác của Idec tại https://dienhathe.com
Xem thêm các Catalog khác của Idec tại https://dienhathe.info
Để nhận báo giá sản phẩm Idec vui lòng gọi: 0907.764.966
Nexans Euromold Connectors & Bushing Interfaces
Euromold Connectors 200 Series Interface Type A Bushing
* Connector Type : 7.9mm Plug-In Pin Contact
* Voltage Range : 11/12kV-24kV
* Current Rating : 250amps
* Specification : CENELEC EN50180 & EN50181
Euromold 158LR Elbow Connectors are used with 200 Series Interface A Bushing.
Nexans Euromold 200 series screened separable connectors are EPDM pre-moulded, high voltage cable terminations for 6.6kV, 11kV, 15kV and 24kV electrical equipment including switchgear, transformers and motors.
Nexans Euromold separable elbow connectors are designed to terminate high voltage polymeric (XLPE EPR) screened (copper wire or copper tape) cables to CENELEC Interface Type A (250amp) bushings with 7.9mm plug-in pins, 11kV-24kV.
Nexans Euromold 200 series separable connectors include Nexans Euromold elbow connectors, Nexans Euromold straight plugs, Nexans Euromold bushings (air, oil and gas insulated switchgear) and Nexans Euromold surge arresters to protect 11kV-24kV electrical equipment.
900 Series Interface F Nexans Euromold Cable Connectors and Bushings connect and terminate HV cables to Interface F bushings on switchgear and transformers up to 42kV. Nexans 944TB Tee Connectors provide high voltage cable terminations using separable tee shape connectors :
Nexans 944TB/G - 12kV 2500Amp 70-80sqmm Conductors
Nexans K944TB/G - 24kV 2500Amp 16-800sqmm Conductors
Nexans M944TB/G - 36kV 2500Amp 35-800sqmm Conductors
Nexans P944TB/G - 42kV 1250Amp 50-800sqmm Conductors
Similar to Asco Du Atex Explosion Proof Operator Hazardous Area Solenoid Valve Operator Zone 21 Zone 22 (20)
Slack (or Teams) Automation for Bonterra Impact Management (fka Social Soluti...Jeffrey Haguewood
Sidekick Solutions uses Bonterra Impact Management (fka Social Solutions Apricot) and automation solutions to integrate data for business workflows.
We believe integration and automation are essential to user experience and the promise of efficient work through technology. Automation is the critical ingredient to realizing that full vision. We develop integration products and services for Bonterra Case Management software to support the deployment of automations for a variety of use cases.
This video focuses on the notifications, alerts, and approval requests using Slack for Bonterra Impact Management. The solutions covered in this webinar can also be deployed for Microsoft Teams.
Interested in deploying notification automations for Bonterra Impact Management? Contact us at sales@sidekicksolutionsllc.com to discuss next steps.
DevOps and Testing slides at DASA ConnectKari Kakkonen
My and Rik Marselis slides at 30.5.2024 DASA Connect conference. We discuss about what is testing, then what is agile testing and finally what is Testing in DevOps. Finally we had lovely workshop with the participants trying to find out different ways to think about quality and testing in different parts of the DevOps infinity loop.
UiPath Test Automation using UiPath Test Suite series, part 3DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 3. In this session, we will cover desktop automation along with UI automation.
Topics covered:
UI automation Introduction,
UI automation Sample
Desktop automation flow
Pradeep Chinnala, Senior Consultant Automation Developer @WonderBotz and UiPath MVP
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...UiPathCommunity
💥 Speed, accuracy, and scaling – discover the superpowers of GenAI in action with UiPath Document Understanding and Communications Mining™:
See how to accelerate model training and optimize model performance with active learning
Learn about the latest enhancements to out-of-the-box document processing – with little to no training required
Get an exclusive demo of the new family of UiPath LLMs – GenAI models specialized for processing different types of documents and messages
This is a hands-on session specifically designed for automation developers and AI enthusiasts seeking to enhance their knowledge in leveraging the latest intelligent document processing capabilities offered by UiPath.
Speakers:
👨🏫 Andras Palfi, Senior Product Manager, UiPath
👩🏫 Lenka Dulovicova, Product Program Manager, UiPath
PHP Frameworks: I want to break free (IPC Berlin 2024)Ralf Eggert
In this presentation, we examine the challenges and limitations of relying too heavily on PHP frameworks in web development. We discuss the history of PHP and its frameworks to understand how this dependence has evolved. The focus will be on providing concrete tips and strategies to reduce reliance on these frameworks, based on real-world examples and practical considerations. The goal is to equip developers with the skills and knowledge to create more flexible and future-proof web applications. We'll explore the importance of maintaining autonomy in a rapidly changing tech landscape and how to make informed decisions in PHP development.
This talk is aimed at encouraging a more independent approach to using PHP frameworks, moving towards a more flexible and future-proof approach to PHP development.
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...Ramesh Iyer
In today's fast-changing business world, Companies that adapt and embrace new ideas often need help to keep up with the competition. However, fostering a culture of innovation takes much work. It takes vision, leadership and willingness to take risks in the right proportion. Sachin Dev Duggal, co-founder of Builder.ai, has perfected the art of this balance, creating a company culture where creativity and growth are nurtured at each stage.
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...DanBrown980551
Do you want to learn how to model and simulate an electrical network from scratch in under an hour?
Then welcome to this PowSyBl workshop, hosted by Rte, the French Transmission System Operator (TSO)!
During the webinar, you will discover the PowSyBl ecosystem as well as handle and study an electrical network through an interactive Python notebook.
PowSyBl is an open source project hosted by LF Energy, which offers a comprehensive set of features for electrical grid modelling and simulation. Among other advanced features, PowSyBl provides:
- A fully editable and extendable library for grid component modelling;
- Visualization tools to display your network;
- Grid simulation tools, such as power flows, security analyses (with or without remedial actions) and sensitivity analyses;
The framework is mostly written in Java, with a Python binding so that Python developers can access PowSyBl functionalities as well.
What you will learn during the webinar:
- For beginners: discover PowSyBl's functionalities through a quick general presentation and the notebook, without needing any expert coding skills;
- For advanced developers: master the skills to efficiently apply PowSyBl functionalities to your real-world scenarios.
Epistemic Interaction - tuning interfaces to provide information for AI supportAlan Dix
Paper presented at SYNERGY workshop at AVI 2024, Genoa, Italy. 3rd June 2024
https://alandix.com/academic/papers/synergy2024-epistemic/
As machine learning integrates deeper into human-computer interactions, the concept of epistemic interaction emerges, aiming to refine these interactions to enhance system adaptability. This approach encourages minor, intentional adjustments in user behaviour to enrich the data available for system learning. This paper introduces epistemic interaction within the context of human-system communication, illustrating how deliberate interaction design can improve system understanding and adaptation. Through concrete examples, we demonstrate the potential of epistemic interaction to significantly advance human-computer interaction by leveraging intuitive human communication strategies to inform system design and functionality, offering a novel pathway for enriching user-system engagements.
Epistemic Interaction - tuning interfaces to provide information for AI support
Asco Du Atex Explosion Proof Operator Hazardous Area Solenoid Valve Operator Zone 21 Zone 22
1. OPERATORS
Series
for potentially explosive atmospheres
II 3 D IP65 T 85°C to T135°C
moulded coil types with connectors
DU
FEATURES
• Operators intended for use in potentially explosive dust atmospheres in
compliance with ATEX-Directive 94/9/EC
• Compliance with the Essential Health and Safety Requirements has been
assured by compliance with European Standards EN 50014 and EN 50281-1-1
• The assembly consisting of the coil and connector has IP65 protection
• CM22/C22A coils are equipped with a size 22 spade plug connector with cable
gland (cable diameter 6 to 8 mm) or a 2 m flying lead; CM25 and CM30 coils
have size 30 spade plug connectors to ISO 4400 and a cable gland (cable
diameter 6 to 10 mm) or a 2 m flying lead
• The coils can be fitted to the following valves:
- Type CM22: series 108, 109, 189 189 banjo and 238 solenoid valves, series
551 solenoid spool valves
- Type C22A: series 256, 356 and 238 solenoid valves (except 256-356 manifold
versions)
- CM25: series 190 and 238 solenoid valves, series 552-553 solenoid spool valves
- Type CM30: series 192 solenoid valves
CONSTRUCTION
Coil
CM22/C22A/CM25
CM30
All
CM22/C22A
CM25/CM30
CM22/CM22A
CM25/CM30
All
All
All
Connector enclosure
Connector specification
Spade plug connector
Wire cross-section
Electrical enclosure protection
Safety code
Moulded epoxy resin or
thermoplastic encapsulant
Moulded epoxy resin encapsulant
Glass-filled polyamide
DIN 43650, 11 mm, industry standard B
ISO 4400 / EN 175301-803, form A
Cable diameter 6 to 8 mm or cable outlet
Cable diameter 6 to 10 mm or cable outlet
1,5 mm2
IP65 (EN 60529)
q II 3 D IP65 T 85°C to T 135°C
ELECTRICAL CHARACTERISTICS
Standard voltages
(Other voltages and 60 Hz on request)
DC (=) : 24V - 48V
AC (~) : 24V - 48V - 115V - 230V / 50 Hz
TEMPERATURE CLASSIFICATION TABLES
DC (=) Solenoids
Pn
(watt)
CM22
C22A
CM25
CM30
solenoid size maximum ambient °C (1)
surface temperature
(watt)
00137GB-2009/R02
Availability, design and specifications are subject to change without notice. All rights reserved.
85°C 100°C 135°C 200°C
insulation class F (155°C) 100% E.D.
2,5
3
4
4 (4)
4
5
•
•
40
40
25
25
•
•
•
solenoid size maximum ambient °C (1)
surface temperature
Pn
•
25
60
60
40
40
25
40
60 (2)
60
60
60 (3)
CM22
C22A
CM25
CM30
AC (~) Solenoids
85°C 100°C 135°C 200°C
insulation class F (155°C) 100% E.D.
2,5/3
3/3,5
5/6,9
4,5/5,5(4)
5/6
5/6,9
•
•
40
40
•
•
•
•
25
25
60
60
25
25
40
40
60 (2)
60
60
60 (3)
Check the wattage compatibility with the product selected.
The minimum allowable ambient temperature is -25°C for the operator. Actual temperature range
can be limited depending on valve operation limits.
(2)
Only for series 238 and 551.
(3)
Only for series 238, 552 and 553.
(4)
Only for series 256, 356 and 238 (except manifold versions).
(1)
I
SPECIFICATION
option code (1)
designation
With cable gland connector
(Versions A and B)
Complete solenoid valve equipped with a type CM22, C22A, CM25 or CM30 coil +
spade plug connector with cable gland
With flying lead connector
Complete solenoid valve equipped with:
a type CM22/C22A coil and spade plug connector size 22 with lead (2 m lead)
a type CM25 or CM30 coil and spade plug connector size 30 with lead (2 m lead)
(1)
DU
(Version A)
(Version B)
DU .. 660518
DU .. 660519
DUX .. TPL 20651
DUX .. TPL 20651
Applicable for the complete catalogue number of a solenoid valve including coil and connector.
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
AllWebsite: www.heattracing.co.uk
leaflets are available on: www.asconumatics.eu
www.thorneanderrick.co.uk
V1067-1
2. OPERATORS II 3 D IP65 T 85°C to T 135°C SERIES DU
ORDERING EXAMPLES:
version A
Series 108, 109, 189, 189 banjo, 190, 192,
541 compact and 551
version B
Series 238, 256, 356, 551, 552 and 553
With cable gland connector
DU
DU
DU
DU
18900032
18900001
19200002
55102005
. 230V / 50 Hz
. 24V / DC
. 115V / 50 Hz
. 230V / 50 Hz
SC
SC
SC
SC
option code
for ATEX compliance
solenoid valve
catalogue number
voltage
DU
DU
DU
DU
E238A001
.
G256A002VMS .
G356A001VMS .
G551A001MS .
230V / 50 Hz
115V / 50 Hz
230V / 50 Hz
230V / 50 Hz
option code for ATEX
compliance (prefix)
solenoid valve
catalogue number
voltage
With flying lead connector
DU
DU
DU
DU
18900032
18900001
19200002
55102005
. 660518. 230V / 50 Hz
. 660518. 24V / DC
. 660519. 115V / 50 Hz
. 660518. 230V / 50 Hz
voltage
option code
connector
with lead
option code
for ATEX compliance
solenoid valve
catalogue number
SC
SC
SC
SC
DU
DU
DU
DU
X
X
X
X
E238A001
.
G256A002VMS .
G356A001VMS .
G551A001MS .
20651
20651
20651
20651
. 230V / 50 Hz
. 115V / 50 Hz
. 230V / 50 Hz
. 230V / 50 Hz
voltage
option code
connector
with lead
option code for ATEX
compliance (prefix)
solenoid valve
catalogue number
INSTALLATION
•
•
•
•
•
The package consists of the solenoid valve, the coil (installed) and the connector (not installed)
The coil is provided with an earthing connection
The operator can be rotated through 360° to select the most favourable position for cable entry
Easy connection with spade plug connector
Installation/maintenance instructions are included with each coil
DIMENSIONS (mm), WEIGHT (kg)
TYPE DU
"DU" Solenoid
EN 50281-1-1
IP65 / II 3 D IP65 T 85°C to T 135°C
B
E
=
E
B
=
A
WHEN
ENERGIZED
Ø6
brown wire
: +
blue wire
: green/yellow wire :
solenoid size + connector
CM22/C22A + cable gland connector
CM22/C22A + flying lead connector
CM25 + cable gland connector (3W/5W)
CM25 + flying lead connector (3W/5W)
CM30 + cable gland connector
CM30 + flying lead connector
(1)
including coil and connector.
All leaflets are available on: www.asconumatics.eu
V1067-2
A
48,5
42
55/56,2
46,5/47,8
55,4
46,9
B
11,5
11,5
15
15
15
15
C
29
29
29,1/31,9
29,1/31,9
38,5
38
D
49
47
56,7
45,65
60,7
49,65
E
22
22
30
30
30
30
G
180°
0°
4 x 90°
0°
4 x 90°
0°
2m
360˚
G
C
D
D
DO NOT
SEPARATE
DO NOT
SEPARATE
weight (1)
0,077
0,207
0,135/0,140
0,260/0,265
0,155
0,275
00137GB-2009/R02
Availability, design and specifications are subject to change without notice. All rights reserved.
360°
G
C
WHEN
ENERGIZED
=
=
A
3. OPERATORS
Series
for potentially explosive atmospheres
II 3 D IP65 T 85°C to T200°C
moulded coil types with connectors
SCDU
FEATURES
• Operators intended for use in potentially explosive dust atmospheres in
compliance with ATEX-Directive 94/9/EC
• Compliance with the Essential Health and Safety Requirements has been
assured by compliance with European Standards EN 50014 and EN 50281-1-1
• The assembly consisting of the coil and connector has IP65 protection
• Easy electrical installation by means of a spade plug connector
• The operator is available as both a push or pull type solenoid and can be supplied on a wide range of valves
CONSTRUCTION
Coil
Connector enclosure
Connector specification
All
All
XM5
M6-MXX-M12
Cable diameter
XM5
M6-MXX-M12
Wire cross-section
All
Electrical enclosure protection All
Safety code
All
Moulded epoxy resin
Glass-filled polyamide
DIN 43650, 11 mm, industry standard B
ISO 4400 / EN 175301-803, form A
6 to 8 mm
6 to 10 mm
1,5 mm2
IP65 (EN 60529)
q II 3 D IP65 T 85°C to T 200°C
ELECTRICAL CHARACTERISTICS
Standard voltages
(Other voltages and 60 Hz on request)
DC (=) : 24V - 48V
AC (~) : 24V - 48V - 115V - 230V / 50 Hz
TEMPERATURE CLASSIFICATION TABLES
00137GB-2006/R01
Availability, design and specifications are subject to change without notice. All rights reserved.
(watt)
XM5
M6
MXX
M12
Pn
solenoid size maximum ambient °C (1)
surface temperature
85°C 100°C 135°C 200°C
insulation class F (155°C) 100% E.D.
1,2 (2)
• 60
60
1,5 (2)
•
1,85 (2)
• 60 75 100
2,5
40
60
•
3,7 (2)
• 60 75 100
4,0
40
60
•
5,8 (2)
• 50 75 100
6,0
75
•
6,3
40
75
•
9,0
40
50
•
10,0 (2)
40
75
•
10,0 (2)
50
100
•
10,5
40
75
•
13,4 (2)
75
•
75
90
14,1 (2)
•
15,4
75
•
16,5 (2)
75
•
16,7
50
•
20,0
50
•
insulation class H (180°C) 100% E.D.
75 100
6,0
•
9,0
40
75
•
10,5
40 100
•
15,4
100
•
16,7
75
•
60
20,0
•
insulation class F (155°C) 10% E.D.
60
75
6,0
•
10,0
60
75
•
10,5
60
75
•
16,7
60
75
•
Check the wattage compatibility with the product
selected.
(1)
The minimum allowable ambient temperature is
-40°C for the operator. Actual temperature range
can be limited depending on valve operation limits.
(2)
AC (~) rectified coil construction.
DC (=) Solenoids
Pn
(watt)
solenoid size maximum ambient °C (1)
surface temperature
XM5
M6
MXX
M12
AC (~) Solenoids
XM5
85°C 100°C 135°C 200°C
insulation class F (155°C) 100% E.D.
1,3
• 60
1,7
60
•
1,8
• 60 75 100
3,0 •
40
60
3,6
• 60 75 100
5,7
• 50 75 100
6,9 •
40
75
8,6 •
40
9,7
40
75
•
10,0
50
100
•
10,7
50
100
•
11,0
40
75
•
11,2
40
75
•
14,0
75
90
•
15,3
50
•
16,8
75
•
19,7
40
•
40
23,0
•
insulation class H (180°C) 100% E.D.
9,7
40
75 100
•
11,2
40
75 100
•
13,3
60
•
15,3
60
75
•
16,8
75 100
•
17,4
50
60
•
19,7
50
•
20,8
40
•
23,0
40
75
•
26,6
40
60
•
29,5
40
•
36,2
40
•
insulation class F (155°C) 10% E.D.
60
75
11,2
•
19,7
60
75
•
60
75
20,8
•
22,0 •
40
60
75
40
60
75
30,0
•
M6-MXX-M12
ORDERING INFORMATION
A valve supplied with the explosionproof
operator will be identified with prefix SCDU
before the catalogue number.
Example:
SC DU G327A001 . 24V/DC
voltage
valve type
option code for ATEX dust
approved operator
spade connector coil
All leaflets are available on: www.asconumatics.eu
V1067-3
I
4. OPERATORS II 3 D IP65 T 85°C to T 200°C SERIES SCDU
INSTALLATION
•
•
•
•
The coil is provided with an earthing connection
The operator can be rotated through 360° to select the most favourable position for cable entry
Easy connection with spade plug connector
Installation/maintenance instructions are included with each coil
DIMENSIONS (mm), WEIGHT (kg)
TYPE SCDU
"SCDU" Solenoid
EN 50281-1-1
IP65 / II 3 D IP65 T 85°C to T 200°C
Pull type solenoid operators
A
D
B
F
G
C
E
R
360˚
DO NOT
SEPARATE
WHEN
ENERGIZED
size
M5
M6
MXX
M12
A
59
80
85
91
B
28
45
50
56
C
17
28
30
33
D
22
39
45
50
E
34
46
53
57
F
52
63
67
58
G
54
78
-
R
180°
4 x 90°
4 x 90°
4 x 90°
weight (1)
0,1/0,15
0,2
0,3/0,35
0,4
Push type solenoid operators
A
D
B
F
DO NOT
SEPARATE
E
R
360˚
size
MXX
M12
(1)
A
85
91
B
50
56
C
30
33
D
45
50
E
61
68
WHEN
ENERGIZED
F
74
65
including coil and connector.
All leaflets are available on: www.asconumatics.eu
V1067-4
R
4 x 90°
4 x 90°
weight (1)
0,35
0,45
00137GB-2006/R01
Availability, design and specifications are subject to change without notice. All rights reserved.
C
5. OPERATORS
Series
for potentially explosive atmospheres
II 3 D IP67 T 85°C to T200°C
steel or stainless steel enclosure
WPDU
WSDU
FEATURES
• Operators intended for use in potentially explosive dust atmospheres in
compliance with ATEX-Directive 94/9/EC
• Compliance with the Essential Health and Safety Requirements has been
assured by compliance with European Standards EN 50014 and EN 50281-1-1
• Easy electrical installation by means of a screw terminal coil
• The solenoid enclosure has a cable gland with integral strain relief for cables
with a diameter from 7 to 12 mm
• Ingress protection degree IP67
• The operator is available as both a push or pull type solenoid and can be supplied on a wide range of valves
CONSTRUCTION
Solenoid enclosure
Cable gland
Core, core tube & plugnut
Shading coil
Electrical enclosure protection
Safety code
WPDU
WSDU
All
All
All
All
All
Zinc plated steel (epoxy coated)
Stainless steel, AISI 316
PA
Stainless steel
Copper or silver
IP67 (EN 60529)
q II 3 D IP67 T 85°C to T 200°C
ELECTRICAL CHARACTERISTICS
Standard voltages
(Other voltages and 60 Hz on request)
DC (=) : 24V - 48V
AC (~) : 24V - 48V - 115V - 230V / 50 Hz
TEMPERATURE CLASSIFICATION TABLES
00137GB-2010/R01
Availability, design and specifications are subject to change without notice. All rights reserved.
(watt)
XM5
M6
MXX
M12
Pn
solenoid size maximum ambient °C (1)
surface temperature
85°C 100°C 135°C 200°C
insulation class F (155°C) 100% E.D.
1,2 (2)
• 60
60
1,5 (2)
•
1,85 (2)
• 60 75 90
3,7 (2)
• 60 75 90
5,8 (2)
• 40 60 90
6,0
50
75
•
9,0
50
•
10,0 (2)
75
•
10,0 (2)
75
•
10,5
75
•
13,4 (2)
40
75
•
14,1 (2)
50
90
•
15,4
40
•
40
75
16,5 (2)
•
insulation class H (180°C) 100% E.D.
50
90
6,0
•
9,0
75
•
10,5
90
•
40
15,4
•
16,7
40
•
insulation class F (155°C) 10% E.D.
40
60
75
6,0
•
10,5
40
60
75
•
16,7
40
60
75
•
Check the wattage compatibility with the product
selected.
(1)
The minimum allowable ambient temperature is
-40°C for the operator. Actual temperature range
can be limited depending on valve operation limits.
(2)
AC (~) rectified coil construction.
ORDERING INFORMATION
DC (=) Solenoids
Pn
(watt)
solenoid size maximum ambient °C (1)
surface temperature
XM5
M6
MXX
M12
AC (~) Solenoids
85°C 100°C 135°C 200°C
insulation class F (155°C) 100% E.D.
1,3
• 60
1,7
60
•
1,8
• 60 75 90
3,6
• 60 75 90
5,7
• 40 60 90
9,7
60
75
•
9,7
90
•
9,7
75
•
10,0
75
•
11,0
75
•
11,2
60
75
•
14,0
50
90
•
15,3
40
50
•
40
75
16,8
•
40
19,7
•
50
23,0
•
insulation class H (180°C) 100% E.D.
60
100
9,7
•
9,7
75
90
•
75
9,7
•
11,2
50
90
•
13,3
40
60
•
40
75
15,3
•
16,8
40
75
•
16,8
40
90
•
16,8
75
•
17,4
60
•
19,7
50
•
20,8
40
•
23,0
75
•
26,6
60
•
insulation class F (155°C) 10% E.D.
60
75
11,2
•
19,7
40
60
75
•
20,8
40
60
75
•
40
60
75
30,0
•
A valve supplied with the explosionproof
operator will be identified with prefix
WPDU or WSDU before the catalogue
number.
Example: WP DU G327A001 . 24V/DC
voltage
valve type
option code for ATEX dust
approved operator
enclosure
I
All leaflets are available on: www.asconumatics.eu
V1067-5
6. OPERATORS II 3 D IP67 T 85°C to T 200°C SERIES WPDU/WSDU
INSTALLATION
•
•
•
•
The package consists of the solenoid valve and operator (installed)
Internal and external earthing connection
The operator can be rotated through 360° to select the most favourable position for cable entry
Installation/maintenance instructions are included with each coil
DIMENSIONS (mm), WEIGHT (kg)
TYPE WPDU/WSDU
"WPDU", "WSDU" Solenoid
EN 50281-1-1
IP67 / II 3 D IP67 T 85°C to T 200°C
Pull type solenoid operator
360
size
WPDU/WSDU-M6
WPDU/WSDU-MXX
WPDU/WSDU-M12
A
77
77
77
B
120
120
120
C
82
82
82
D
26
23
21
E
64
62
65
weight
0,48
0,55
0,67
D
25
31
30
E
63
69
73
weight
0,50
0,59
0,70
D
23
E
80
weight
0,68
Push type solenoid operator
size
WPDU/WSDU-M6
WPDU/WSDU-MXX
WPDU/WSDU-M12
A
77
77
77
B
120
120
120
C
82
82
82
Pull type solenoid operator
360
size
WPDU/WSDU-MXX
A
77
B
120
C
82
All leaflets are available on: www.asconumatics.eu
V1067-6
00137GB-2010/R01
Availability, design and specifications are subject to change without notice. All rights reserved.
360
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.heattracing.co.uk
www.thorneanderrick.co.uk