SlideShare a Scribd company logo
1 of 15
Download to read offline
Manual No. 090820-4 Rev.A
Electromagnetic Flow Meter
Copyright Reserved, Zero Instrument Corporation
1
Content
1.0 GENERAL INFORMATION................................................................................................2
2.0 SPECIFICATIONS.................................................................................................................4
3.0 MODEL AND SELECTION................................................................................................. 5
4.0 CAUTIONS FOR INSTALLATION....................................................................................6
5.0 ELECTRICAL WIRING....................................................................................................... 9
6.0 PROGRAMMING AND SETUP.......................................................................................... 9
7.0 TROUBLESHOOTING....................................................................................................... 13
Copyright Reserved, Zero Instrument Corporation
2
1.0 GENERAL INFORMATION
This manual will assist you in installing, using and maintaining your Zero Instrument flow
meter. It is your responsibility to make sure that all operators have access to adequate
instructions about safe operating and maintenance
procedure.………………………………………………
Warning
For your safety, review the major warnings and cautions below before operating your
equipment.……………………………………………………………………………..
1. Use only fluids that are compatible with
the housing material and wetted components
of your meter.
2. When measuring flammable liquids,
observe precautions against fire or explosion.
3. When handling hazardous liquids, always
follow the fluids manufacturer’s safety
precautions.
4. When working in hazardous environments,
always exercise appropriate safety
precautions.
…………………………..
5. During meter removal, fluids may spill.
Follow the fluids manufacturer’s safety
precautions for clean up of minor spills.
…………………………..
6. When tightening the meter, use a
wrench only on the wrench flats. …………...
7. For best results, calibrate the meter at
least 1 time per year.……………………
Product Description
Zero Instrument LDG electromagnetic flow meters are intended for fluid measurement in most
industries including water, wastewater, food and beverage, pharmaceutical and chemical.
……….
There are two basic components of Zero Instrument electromagnetic flow meter: 1)The
Detector, which includes the flow tube, isolating liner and measuring electrodes, and 2) The
Converter, which is the electronic device responsible for signal processing, flow calculation,
display and output signals.
The materials of construction of the wetted parts (liner and electrodes) should be appropriate for
the specifications on the intended type of service. Review of the compatibilities consistent with
the specifications is recommended.
All Zero Instrument’s electromagnetic flow meters are factory tested and calibrated. A
calibration certificate is included in the shipment of each meter.
Copyright Reserved, Zero Instrument Corporation
3
Unpacking and Inspection
Upon receipt, examine your meter for visible damage. The meter is a precision measuring
instrument and should be handled carefully. Remove the protective plugs and caps for a
thorough inspection. If any items are damaged or missing, contact Zero Instrument.
Make sure the flow meter model meets your specific needs. For your future reference, it might
be useful to record this information on nameplate in the manual in case it becomes unreadable
on the meter.
Transportation and Handling
Do not lift the detector from the Converter
housing, the junction box or the connecting
cable. Use lifting lugs for larger sizes is
recommended. Very large meter sizes are
packed and crated with the meter laying on
its side for shipping safety and stability
reasons. In order to lift the meter in vertical
position, it's recommended to use a sling
rigged method as shown below.
If using a forklift, do not lift the detector
from its body between the flanges. The
housing could be accidentally dented and
permanent damage could be caused to the
internal coil assemblies.
Warning: NEVER introduce the
forklift, chains, wire slings or any other
sharp object inside the flow tube for lifting
or handling purpose. This could permanently
damage the isolating liner and could render
the meter inoperable.
Copyright Reserved, Zero Instrument Corporation
4
2.0 SPECIFICATIONS
Converter:
Power Supply: 85-265Vac (Optional: 18-36
Vdc)
Power Consumption: 10W
Accuracy:
± 0.5% accuracy of rate from 0.5-10 m/s
± 1.0% accuracy of rate from 0.1-0.5 m/s
Repeatability: 0.2%
Minimum Fluid Conductivity:
5.0 micromhos/cm
Flow Direction: Unidirectional or
bidirectional, 2 separate totalizers
(programmable)
Analog Outputs: 4-20mA, 500ohms Max
Load
Output Frequency: Scaled Pulse output,
(open collector) Max 5Khz
Noise Damping: Programmable
Pulse Width: Programmable up to 500ms
Zero-point Stability: Automatic correction
Housing: Cast aluminum, powder coated
paint
Mounting: Integral mount or remote mount
Ambient Temperature: -4 to 140° F (-20 to
60° C)
Detector:
Flow Range: 0.03-10 m/s
Sizes: 10 to 2200 mm
Min. Conductivity: 5 micromhos/cm
Accuracy:
± 0.5% accuracy of rate from 0.5-10 m/s
± 1.0% accuracy of rate from 0.1-0.5 m/s
Electrode Materials:
Standard: 316 Stainless Steel
Optional: Tantalum
Liner Material: PTFE, FEP (Rubber)
Fluid Temperature:
PTFE: 100°C Standard (Customized: 180°C)
FEP: 60°C
Presure Limits:
1.0 Mpa; Optional 1.6; 2.5; 4.0 Mpa
Coil Power: Pulsed DC
Ambient Temperature: -20°C to 60°C
Pipe Spool Material: 316 Stainless Steel
Meter Housing Material:
Carbon Steel welded
Flanges:
Carbon Steel - Standard (ISO 7005-1)
316 Stainless Steel - Optional
Optional Stainless Steel Grounding Rings
Measurable Flow Rate Range:
Note: The flow range as blow is for recommended use. Consult the factory if you have special
requirement.
Diameter (mm) 10 15 20 25 32 40 50 65
Qmin (m3
/h) 0.08 0.34 0.34 0.53 0.87 1.35 2.1 3.5
Qmax (m3
/h) 2 8 8 12 20 32 49 84
Diameter (mm) 80 100 125 150 200 250 300 350
Qmin (m3
/h) 5.4 8.5 13 19 34 53 76 104
Qmax (m3
/h) 127 197 310 445 791 1236 1780 2423
Diameter (mm) 400 450 500 550 600 700 800 900
Qmin (m3
/h) 136 191 212 263 305 415 543 760
Qmax (m3
/h) 3165 4294 4945 6322 7122 9693 12660 17634
Copyright Reserved, Zero Instrument Corporation
5
3.0 MODEL AND SELECTION
Model Selection (See Table 1)
Table 1. Model Selection Guidance
Model Suffix Code
Description
LDG- □ /□ /□ /□ /□ /□ /□ /□ /□
Diameter 10-2200mm
combination
S Integrated type
L Remote type
Electrode
Material
M Stainless steel 316
T Ti
D Ta
H Hastelloy alloy
P Pt
N Ni
Signal Output
0 No output
1 4-20mA/1-5KHz
Liner material
X FEP
F PTFE
Display Unit
0 No display unit
1 Display unit
Communication
0 No communication
1 RS485
2 MODBUS
Grounding Ring
0 No grounding ring
1 Grounding ring
Maximum Flow (n)
Maximum flow
(measuring range) m3
/h
Copyright Reserved, Zero Instrument Corporation
6
4.0 CAUTIONS FOR INSTALLATION
Mounting Positions
 Pipes must be fully filled with liquids. It
is essential that pipes remain fully filled
at all times, otherwise flow rate
indications may be affected and
measurement errors may be caused.
 Avoid Air Bubbles. If air bubbles enter
a measurement pipe, flow rate
indications may be affected and
measurement errors may be caused.
 Avoid all pipe locations where the flow
is pulsating, such as in the outlet side of
piston or diaphragm pumps.
 Avoid locations near equipment
producing electrical interference such as
electric motors, transformers, variable
frequency, etc.
 Install the meter with enough room for
future access for maintenance purposes.
 The mag meter isolating liner, whether
if it is PTFE or Rubber, is not intended
to be used as gasket material. Standard
gaskets (not provided) should be
installed to ensure a proper hydraulic
seal. When installing the gaskets, make
sure they are properly centered to avoid
flow restriction or turbulence. Do not
use graphite or any electrically
conductive sealing compound to hold
the gaskets in place during installation.
This could affect the reading accuracy
of the measuring signal.
Warning: Precaution for direct sunshine and rain when the meter is installed outside.
Required Lengths of Straight Runs
For optimum accuracy performance, it is required to provide sufficient inlet and outlet straight
pipe runs. An equivalent to 3 diameters of straight pipe is required on the inlet side, and 2
diameters on the outlet side. There are no special requirements for standard concentric pipe
reducers. See diagram1 for required straight runs when there is altering device.
Copyright Reserved, Zero Instrument Corporation
7
Diagram 1. Required straight runs
Special Notice
 When the meter contains removable coverplates. Leave the coverplate installed unless
accessory modules specify removal. Don’t remove the coverplates when the meter is
powered, or electrical shock and explosion hazard can be caused.
Flange Connections
The flange follows GB/T 9119-2000 (ISO 7005-1) RF (Raised Face).
Note: flange can be customized following other criterias.
Use a gasket between the meter flange and mating flange. Determine the material of the gasket
based on the operating conditions and type of fluid.………………………………………….
Note: Do not over tighten the flange bolts. This may cause the gasket to be compressed into the
flow stream and may decrease the accuracy of the meter.
Installation Dimensions
See Figure 1 and Table 2 for detailed dimensions.
Figure 1: Drawings for Integrated/Remote Electromagnetic Flow Meter
Copyright Reserved, Zero Instrument Corporation
8
Table 2. Dimensions (Unit: mm)
Diameter DN a D Do n × Φ A
10 230 90 60 4 × 14
15 230 95 65 4 × 14
20 230 105 75 4 × 14
25 230 115 85 4 × 14
32 230 140 100 4 × 18
40 230 150 110 4 × 18
50 230 165 125 4 × 18
65 230 185 145 8 × 18
80 230 200 160 8 × 18
100 230 220 180 8 × 18
125 280 245 210 8 × 18
150 280 285 240 8 × 22
200 310 340 295 12 × 22
250 360 405 355 12 × 22
300 460 460 410 12 × 22
350 460 520 470 16 × 22
400 460 580 525 16 × 26
450 460 640 585 20 × 26
500 600 715 650 20 × 26
600 600 840 770 20 × 30
700 700 895 840 24 × 33
800 800 1015 950 24 × 33
900 900 1110 1050 28 × 33
1000 1000 1230 1160 28 × 36
1200 1200 1405 1340 32 × 33
1400 1400 1630 1560 36 × 36
1600 1600 1830 1760 40 × 36
1800 1800 2045 1970 44 × 39
2000 2000 2265 2180 48 × 42
2200 2200 2405 2315 52 × 45
Copyright Reserved, Zero Instrument Corporation
9
5.0 ELECTRICAL WIRING
Warning: Electrical Hazard
Disconnect power before beginning installation.
Terminal Configuration
Terminal Wiring
Warning: The mag flow meter is powered by EITHER 220Vac OR 24V DC. Please
use right power supply or maybe cause permanent damage on meter.
6.0 PROGRAMMING AND SETUP
The display panel comes preprogrammed from the factory and in most instances will not require
any additional manipulation. However, if you will be using the flow signal outputs or need to
reprogram the meter to suit your particular needs, it will be necessary to familiarize yourself
with the programming procedures.
10
Figure 2. Enter Parameter and Display Panel Illustration
Figure 3. Detailed Illustration for Menu - Basic
11
Figure 4. Detailed Illustration for Menu - System
12
Figure 5. Detailed Illustration for Menu – Calibration
Notice: The Menu - Detail is only for factory programming, and it’s not permitted for user to
change these setting in Menu – Detail.
… … … … … … … … … … … … … . . .
13
7.0 TROUBLESHOOTING
Symptom Probable Cause Solution
Measurement is not
accurate 1. Parameter wrong
Check the parameters (Transmitter,
K-factor and size)
2. Pipe is not fully filled Check if meter is fully filled
Flow rate indication
is unstable 1. Grounding issue
Make sure meter is properly
grounded to a good earth ground
2. Air
Make sure fluid does not contain air
bubbles
3. Converter location – outside
electrical interference
Make sure Converter is not too
close to sources of electrical
interference
No Display 1. No power Apply correct power
2. Incorrect power Check power value
3. Wiring connections
Check power input/output
connections
4. Fuse blown Replace fuse
14
Limited Warranty Policy
FOR NON-WARRANTY REPAIRS OR CALIBRATIONS, consult Zero Instrument for
current repair/calibration charges. Have the following information available BEFORE
contacting Zero Instrument:
1. P.O. number to cover the COST of the repair/calibration,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
Zero Instrument hereby provides a limited warranty against defects in materials and
workmanship. This product includes a 1-year warranty. The warranty period shall begin on the
date of the original new equipment purchase. Warrantor’s obligation hereunder shall be limited
to repairing defective workmanship or replacing or repairing any defective
parts.。。。。。。。。。。 …
In the event Purchaser believes the Zero Instrument product is defective, the product must be
returned to Zero Instrument, transportation prepaid by Purchaser, within the appropriate
warranty period relative to the product. If Zero Instrument’s inspection determines the
workmanship or materials are defective and the required maintenance has been performed and,
has been properly installed and operated, the product will be either repaired or replaced, at Zero
Instrument’s sole determination, free of additional charge, and the goods will be returned,
transportation paid by Zero Instrument, using a transportation method selected by Zero
Instrument.………………………………………………………
Prior to returning the product to Zero Instrument, Purchaser must obtain a Returned Material
Authorization (RMA) Number from Zero Instrument’s Customer Service Department within 30
days after discovery of a purported breach of warranty, but not later than the warranty period;
otherwise, such claims shall be deemed
waived. ……… ……………………………………….....
If Zero Instrument’s inspection reveals the Zero Instrument product to be free of defects in
material and workmanship or such inspection reveals the goods were improperly used,
improperly installed, and/or improperly selected for service intended, Zero Instrument will
notify the purchaser in writing and will deliver the goods back to Purchaser upon receipt of
Purchaser's written instructions and agreement to pay the cost of transportation. If Purchaser
does not respond within thirty (30) days after notice from Zero Instrument, the goods will be
disposed of in Zero Instrument’s discretion.
Zero Instrument does not warrant the product to meet the requirements of any safety code or
other jurisdiction, and Purchaser assumes all risk and liability whatsoever resulting from the use
thereof, whether used singlely or in combination with other machines or apparatus.
This warranty shall not apply to any Zero Instrument product or parts thereof, which have been

More Related Content

Similar to Magnetic Flowmeter Selection Model Zero Instrument.pdf

RBEFB Battery Operated Magnetic Flow Meter Catalog
RBEFB Battery Operated Magnetic Flow Meter  CatalogRBEFB Battery Operated Magnetic Flow Meter  Catalog
RBEFB Battery Operated Magnetic Flow Meter Catalogjessy Lee RB Flowmeter
 
Vmi insertion type electromagnetic flow-meter instruction manual
Vmi insertion type electromagnetic flow-meter instruction manualVmi insertion type electromagnetic flow-meter instruction manual
Vmi insertion type electromagnetic flow-meter instruction manualPERAM RAVI
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalogKevin Yang
 
Micronics U1000-HM Clamp On Ultrasonic Heat Meter - User Manual
Micronics U1000-HM Clamp On Ultrasonic Heat Meter - User ManualMicronics U1000-HM Clamp On Ultrasonic Heat Meter - User Manual
Micronics U1000-HM Clamp On Ultrasonic Heat Meter - User ManualThorne & Derrick UK
 
single-phase-acr10r-d16te-manual.pdf
single-phase-acr10r-d16te-manual.pdfsingle-phase-acr10r-d16te-manual.pdf
single-phase-acr10r-d16te-manual.pdfacrelenergy
 
i196_2.pdf
i196_2.pdfi196_2.pdf
i196_2.pdfDhpCia
 
09 - Measuring Instuments - Fuji Electric
09 - Measuring Instuments - Fuji Electric09 - Measuring Instuments - Fuji Electric
09 - Measuring Instuments - Fuji ElectricCTY TNHH HẠO PHƯƠNG
 
Ct2000 es manual_english_version_1[1].0
Ct2000 es manual_english_version_1[1].0Ct2000 es manual_english_version_1[1].0
Ct2000 es manual_english_version_1[1].0Toàn Huỳnh
 

Similar to Magnetic Flowmeter Selection Model Zero Instrument.pdf (20)

ZIPP Wireless torque transducer operation manual
ZIPP Wireless torque transducer operation manualZIPP Wireless torque transducer operation manual
ZIPP Wireless torque transducer operation manual
 
RBEFB Battery Operated Magnetic Flow Meter Catalog
RBEFB Battery Operated Magnetic Flow Meter  CatalogRBEFB Battery Operated Magnetic Flow Meter  Catalog
RBEFB Battery Operated Magnetic Flow Meter Catalog
 
Vmi insertion type electromagnetic flow-meter instruction manual
Vmi insertion type electromagnetic flow-meter instruction manualVmi insertion type electromagnetic flow-meter instruction manual
Vmi insertion type electromagnetic flow-meter instruction manual
 
Vibrating Rod Point Level Switch for Solids India
Vibrating Rod Point Level Switch for Solids IndiaVibrating Rod Point Level Switch for Solids India
Vibrating Rod Point Level Switch for Solids India
 
Vibrating Rod Level Switch for Solids.pdf
Vibrating Rod Level Switch for Solids.pdfVibrating Rod Level Switch for Solids.pdf
Vibrating Rod Level Switch for Solids.pdf
 
Vibrating Fork Level Limit Switch for Solids.pdf
Vibrating Fork Level Limit Switch for Solids.pdfVibrating Fork Level Limit Switch for Solids.pdf
Vibrating Fork Level Limit Switch for Solids.pdf
 
High frequency radar level meter zero902
High frequency radar  level meter zero902High frequency radar  level meter zero902
High frequency radar level meter zero902
 
Catalog biến tần Inovance MD310
Catalog biến tần Inovance MD310Catalog biến tần Inovance MD310
Catalog biến tần Inovance MD310
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalog
 
Micronics U1000-HM Clamp On Ultrasonic Heat Meter - User Manual
Micronics U1000-HM Clamp On Ultrasonic Heat Meter - User ManualMicronics U1000-HM Clamp On Ultrasonic Heat Meter - User Manual
Micronics U1000-HM Clamp On Ultrasonic Heat Meter - User Manual
 
Electromagnetic Flow Monitor Magphant
Electromagnetic Flow Monitor MagphantElectromagnetic Flow Monitor Magphant
Electromagnetic Flow Monitor Magphant
 
instruction
instruction instruction
instruction
 
Guided Wave Radar Level Meter.pdf
Guided Wave Radar Level Meter.pdfGuided Wave Radar Level Meter.pdf
Guided Wave Radar Level Meter.pdf
 
Electromagnetic flow meter
Electromagnetic flow meterElectromagnetic flow meter
Electromagnetic flow meter
 
Zero100E insertion type electromagnetic flow meter catalog
Zero100E insertion type electromagnetic flow meter catalogZero100E insertion type electromagnetic flow meter catalog
Zero100E insertion type electromagnetic flow meter catalog
 
single-phase-acr10r-d16te-manual.pdf
single-phase-acr10r-d16te-manual.pdfsingle-phase-acr10r-d16te-manual.pdf
single-phase-acr10r-d16te-manual.pdf
 
i196_2.pdf
i196_2.pdfi196_2.pdf
i196_2.pdf
 
Tp+manual
Tp+manualTp+manual
Tp+manual
 
09 - Measuring Instuments - Fuji Electric
09 - Measuring Instuments - Fuji Electric09 - Measuring Instuments - Fuji Electric
09 - Measuring Instuments - Fuji Electric
 
Ct2000 es manual_english_version_1[1].0
Ct2000 es manual_english_version_1[1].0Ct2000 es manual_english_version_1[1].0
Ct2000 es manual_english_version_1[1].0
 

More from Dalian Zero Instrument Technology Co., Ltd China

More from Dalian Zero Instrument Technology Co., Ltd China (20)

An Article To Read And Understand The Radar Level Meter Antenna Knowledge
An Article To Read And Understand The Radar Level Meter Antenna KnowledgeAn Article To Read And Understand The Radar Level Meter Antenna Knowledge
An Article To Read And Understand The Radar Level Meter Antenna Knowledge
 
Analysis Of The Application Of Radar Level Meter In The Level Measurement Of ...
Analysis Of The Application Of Radar Level Meter In The Level Measurement Of ...Analysis Of The Application Of Radar Level Meter In The Level Measurement Of ...
Analysis Of The Application Of Radar Level Meter In The Level Measurement Of ...
 
Radar Level Meter Easily Measures Levels In Small Silos For Baking Ingredients
Radar Level Meter Easily Measures Levels In Small Silos For Baking IngredientsRadar Level Meter Easily Measures Levels In Small Silos For Baking Ingredients
Radar Level Meter Easily Measures Levels In Small Silos For Baking Ingredients
 
Radar Level Meter Brand Selection Guideline
Radar Level Meter Brand Selection GuidelineRadar Level Meter Brand Selection Guideline
Radar Level Meter Brand Selection Guideline
 
Application Of Guided Wave Radar Level Meter In Fuel Level Measurement In Shi...
Application Of Guided Wave Radar Level Meter In Fuel Level Measurement In Shi...Application Of Guided Wave Radar Level Meter In Fuel Level Measurement In Shi...
Application Of Guided Wave Radar Level Meter In Fuel Level Measurement In Shi...
 
Radar Level Gauges A Sharp Tool For Level Monitoring In Sulphur Pits
Radar Level Gauges A Sharp Tool For Level Monitoring In Sulphur PitsRadar Level Gauges A Sharp Tool For Level Monitoring In Sulphur Pits
Radar Level Gauges A Sharp Tool For Level Monitoring In Sulphur Pits
 
Radar Level Meter Selection And Application In Power Plants
Radar Level Meter Selection And Application In Power PlantsRadar Level Meter Selection And Application In Power Plants
Radar Level Meter Selection And Application In Power Plants
 
Application Of Guided Wave Radar Level Meter In The Level Measurement Of Amin...
Application Of Guided Wave Radar Level Meter In The Level Measurement Of Amin...Application Of Guided Wave Radar Level Meter In The Level Measurement Of Amin...
Application Of Guided Wave Radar Level Meter In The Level Measurement Of Amin...
 
How To Judge The Advantages And Disadvantages Of Radar Level Meter
How To Judge The Advantages And Disadvantages Of Radar Level MeterHow To Judge The Advantages And Disadvantages Of Radar Level Meter
How To Judge The Advantages And Disadvantages Of Radar Level Meter
 
A Brief Analysis Of Radar Level Meter Measuring Liquid Level In Leachate Wells
A Brief Analysis Of Radar Level Meter Measuring Liquid Level In Leachate WellsA Brief Analysis Of Radar Level Meter Measuring Liquid Level In Leachate Wells
A Brief Analysis Of Radar Level Meter Measuring Liquid Level In Leachate Wells
 
Application Of Radar Level Meter In Level Measurement Of Broken Glass Silo
Application Of Radar Level Meter In Level Measurement Of Broken Glass SiloApplication Of Radar Level Meter In Level Measurement Of Broken Glass Silo
Application Of Radar Level Meter In Level Measurement Of Broken Glass Silo
 
Misunderstandings In The Installation Of Radar Level Gauges
Misunderstandings In The Installation Of Radar Level GaugesMisunderstandings In The Installation Of Radar Level Gauges
Misunderstandings In The Installation Of Radar Level Gauges
 
Application Of Radar Level Meter In Liquid Level Measurement In Main Building...
Application Of Radar Level Meter In Liquid Level Measurement In Main Building...Application Of Radar Level Meter In Liquid Level Measurement In Main Building...
Application Of Radar Level Meter In Liquid Level Measurement In Main Building...
 
Application Of Radar Level Meter In Material Level Measurement Of Raw Materia...
Application Of Radar Level Meter In Material Level Measurement Of Raw Materia...Application Of Radar Level Meter In Material Level Measurement Of Raw Materia...
Application Of Radar Level Meter In Material Level Measurement Of Raw Materia...
 
How To Deal With Radar Level Gauge Distortion
How To Deal With Radar Level Gauge DistortionHow To Deal With Radar Level Gauge Distortion
How To Deal With Radar Level Gauge Distortion
 
Why Does The Transmitter Use 4-20mA Why Choose 4-20mA Instead Of 0-20mA
Why Does The Transmitter Use 4-20mA Why Choose 4-20mA Instead Of 0-20mAWhy Does The Transmitter Use 4-20mA Why Choose 4-20mA Instead Of 0-20mA
Why Does The Transmitter Use 4-20mA Why Choose 4-20mA Instead Of 0-20mA
 
How To Eliminate Interference Encountered By Radar Level Gauges
How To Eliminate Interference Encountered By Radar Level GaugesHow To Eliminate Interference Encountered By Radar Level Gauges
How To Eliminate Interference Encountered By Radar Level Gauges
 
Can Radar Level Gauge Measure Small Biogas Pools.doc
Can Radar Level Gauge Measure Small Biogas Pools.docCan Radar Level Gauge Measure Small Biogas Pools.doc
Can Radar Level Gauge Measure Small Biogas Pools.doc
 
Global Market Trends in Coriolis Mass Flow Meter Technology
Global Market Trends in Coriolis Mass Flow Meter TechnologyGlobal Market Trends in Coriolis Mass Flow Meter Technology
Global Market Trends in Coriolis Mass Flow Meter Technology
 
Application Of Radar Level Gauge In Offshore Oil And Gas Extraction Industry
Application Of Radar Level Gauge In Offshore Oil And Gas Extraction IndustryApplication Of Radar Level Gauge In Offshore Oil And Gas Extraction Industry
Application Of Radar Level Gauge In Offshore Oil And Gas Extraction Industry
 

Recently uploaded

Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckHajeJanKamps
 
CATALOG cáp điện Goldcup (bảng giá) 1.4.2024.PDF
CATALOG cáp điện Goldcup (bảng giá) 1.4.2024.PDFCATALOG cáp điện Goldcup (bảng giá) 1.4.2024.PDF
CATALOG cáp điện Goldcup (bảng giá) 1.4.2024.PDFOrient Homes
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncrdollysharma2066
 
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCRsoniya singh
 
rishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfrishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfmuskan1121w
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfpollardmorgan
 
Catalogue ONG NUOC PPR DE NHAT .pdf
Catalogue ONG NUOC PPR DE NHAT      .pdfCatalogue ONG NUOC PPR DE NHAT      .pdf
Catalogue ONG NUOC PPR DE NHAT .pdfOrient Homes
 
Investment analysis and portfolio management
Investment analysis and portfolio managementInvestment analysis and portfolio management
Investment analysis and portfolio managementJunaidKhan750825
 
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...lizamodels9
 
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCRsoniya singh
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewasmakika9823
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Timedelhimodelshub1
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst SummitHolger Mueller
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...lizamodels9
 
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsCash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsApsara Of India
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessAggregage
 
Non Text Magic Studio Magic Design for Presentations L&P.pptx
Non Text Magic Studio Magic Design for Presentations L&P.pptxNon Text Magic Studio Magic Design for Presentations L&P.pptx
Non Text Magic Studio Magic Design for Presentations L&P.pptxAbhayThakur200703
 
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 

Recently uploaded (20)

Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
 
CATALOG cáp điện Goldcup (bảng giá) 1.4.2024.PDF
CATALOG cáp điện Goldcup (bảng giá) 1.4.2024.PDFCATALOG cáp điện Goldcup (bảng giá) 1.4.2024.PDF
CATALOG cáp điện Goldcup (bảng giá) 1.4.2024.PDF
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
 
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Keshav Puram 🔝 Delhi NCR
 
rishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfrishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdf
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
 
Catalogue ONG NUOC PPR DE NHAT .pdf
Catalogue ONG NUOC PPR DE NHAT      .pdfCatalogue ONG NUOC PPR DE NHAT      .pdf
Catalogue ONG NUOC PPR DE NHAT .pdf
 
Investment analysis and portfolio management
Investment analysis and portfolio managementInvestment analysis and portfolio management
Investment analysis and portfolio management
 
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
 
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Hauz Khas 🔝 Delhi NCR
 
Enjoy ➥8448380779▻ Call Girls In Sector 18 Noida Escorts Delhi NCR
Enjoy ➥8448380779▻ Call Girls In Sector 18 Noida Escorts Delhi NCREnjoy ➥8448380779▻ Call Girls In Sector 18 Noida Escorts Delhi NCR
Enjoy ➥8448380779▻ Call Girls In Sector 18 Noida Escorts Delhi NCR
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Time
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst Summit
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
 
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsCash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for Success
 
Non Text Magic Studio Magic Design for Presentations L&P.pptx
Non Text Magic Studio Magic Design for Presentations L&P.pptxNon Text Magic Studio Magic Design for Presentations L&P.pptx
Non Text Magic Studio Magic Design for Presentations L&P.pptx
 
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 

Magnetic Flowmeter Selection Model Zero Instrument.pdf

  • 1. Manual No. 090820-4 Rev.A Electromagnetic Flow Meter
  • 2. Copyright Reserved, Zero Instrument Corporation 1 Content 1.0 GENERAL INFORMATION................................................................................................2 2.0 SPECIFICATIONS.................................................................................................................4 3.0 MODEL AND SELECTION................................................................................................. 5 4.0 CAUTIONS FOR INSTALLATION....................................................................................6 5.0 ELECTRICAL WIRING....................................................................................................... 9 6.0 PROGRAMMING AND SETUP.......................................................................................... 9 7.0 TROUBLESHOOTING....................................................................................................... 13
  • 3. Copyright Reserved, Zero Instrument Corporation 2 1.0 GENERAL INFORMATION This manual will assist you in installing, using and maintaining your Zero Instrument flow meter. It is your responsibility to make sure that all operators have access to adequate instructions about safe operating and maintenance procedure.……………………………………………… Warning For your safety, review the major warnings and cautions below before operating your equipment.…………………………………………………………………………….. 1. Use only fluids that are compatible with the housing material and wetted components of your meter. 2. When measuring flammable liquids, observe precautions against fire or explosion. 3. When handling hazardous liquids, always follow the fluids manufacturer’s safety precautions. 4. When working in hazardous environments, always exercise appropriate safety precautions. ………………………….. 5. During meter removal, fluids may spill. Follow the fluids manufacturer’s safety precautions for clean up of minor spills. ………………………….. 6. When tightening the meter, use a wrench only on the wrench flats. …………... 7. For best results, calibrate the meter at least 1 time per year.…………………… Product Description Zero Instrument LDG electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical. ………. There are two basic components of Zero Instrument electromagnetic flow meter: 1)The Detector, which includes the flow tube, isolating liner and measuring electrodes, and 2) The Converter, which is the electronic device responsible for signal processing, flow calculation, display and output signals. The materials of construction of the wetted parts (liner and electrodes) should be appropriate for the specifications on the intended type of service. Review of the compatibilities consistent with the specifications is recommended. All Zero Instrument’s electromagnetic flow meters are factory tested and calibrated. A calibration certificate is included in the shipment of each meter.
  • 4. Copyright Reserved, Zero Instrument Corporation 3 Unpacking and Inspection Upon receipt, examine your meter for visible damage. The meter is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact Zero Instrument. Make sure the flow meter model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the meter. Transportation and Handling Do not lift the detector from the Converter housing, the junction box or the connecting cable. Use lifting lugs for larger sizes is recommended. Very large meter sizes are packed and crated with the meter laying on its side for shipping safety and stability reasons. In order to lift the meter in vertical position, it's recommended to use a sling rigged method as shown below. If using a forklift, do not lift the detector from its body between the flanges. The housing could be accidentally dented and permanent damage could be caused to the internal coil assemblies. Warning: NEVER introduce the forklift, chains, wire slings or any other sharp object inside the flow tube for lifting or handling purpose. This could permanently damage the isolating liner and could render the meter inoperable.
  • 5. Copyright Reserved, Zero Instrument Corporation 4 2.0 SPECIFICATIONS Converter: Power Supply: 85-265Vac (Optional: 18-36 Vdc) Power Consumption: 10W Accuracy: ± 0.5% accuracy of rate from 0.5-10 m/s ± 1.0% accuracy of rate from 0.1-0.5 m/s Repeatability: 0.2% Minimum Fluid Conductivity: 5.0 micromhos/cm Flow Direction: Unidirectional or bidirectional, 2 separate totalizers (programmable) Analog Outputs: 4-20mA, 500ohms Max Load Output Frequency: Scaled Pulse output, (open collector) Max 5Khz Noise Damping: Programmable Pulse Width: Programmable up to 500ms Zero-point Stability: Automatic correction Housing: Cast aluminum, powder coated paint Mounting: Integral mount or remote mount Ambient Temperature: -4 to 140° F (-20 to 60° C) Detector: Flow Range: 0.03-10 m/s Sizes: 10 to 2200 mm Min. Conductivity: 5 micromhos/cm Accuracy: ± 0.5% accuracy of rate from 0.5-10 m/s ± 1.0% accuracy of rate from 0.1-0.5 m/s Electrode Materials: Standard: 316 Stainless Steel Optional: Tantalum Liner Material: PTFE, FEP (Rubber) Fluid Temperature: PTFE: 100°C Standard (Customized: 180°C) FEP: 60°C Presure Limits: 1.0 Mpa; Optional 1.6; 2.5; 4.0 Mpa Coil Power: Pulsed DC Ambient Temperature: -20°C to 60°C Pipe Spool Material: 316 Stainless Steel Meter Housing Material: Carbon Steel welded Flanges: Carbon Steel - Standard (ISO 7005-1) 316 Stainless Steel - Optional Optional Stainless Steel Grounding Rings Measurable Flow Rate Range: Note: The flow range as blow is for recommended use. Consult the factory if you have special requirement. Diameter (mm) 10 15 20 25 32 40 50 65 Qmin (m3 /h) 0.08 0.34 0.34 0.53 0.87 1.35 2.1 3.5 Qmax (m3 /h) 2 8 8 12 20 32 49 84 Diameter (mm) 80 100 125 150 200 250 300 350 Qmin (m3 /h) 5.4 8.5 13 19 34 53 76 104 Qmax (m3 /h) 127 197 310 445 791 1236 1780 2423 Diameter (mm) 400 450 500 550 600 700 800 900 Qmin (m3 /h) 136 191 212 263 305 415 543 760 Qmax (m3 /h) 3165 4294 4945 6322 7122 9693 12660 17634
  • 6. Copyright Reserved, Zero Instrument Corporation 5 3.0 MODEL AND SELECTION Model Selection (See Table 1) Table 1. Model Selection Guidance Model Suffix Code Description LDG- □ /□ /□ /□ /□ /□ /□ /□ /□ Diameter 10-2200mm combination S Integrated type L Remote type Electrode Material M Stainless steel 316 T Ti D Ta H Hastelloy alloy P Pt N Ni Signal Output 0 No output 1 4-20mA/1-5KHz Liner material X FEP F PTFE Display Unit 0 No display unit 1 Display unit Communication 0 No communication 1 RS485 2 MODBUS Grounding Ring 0 No grounding ring 1 Grounding ring Maximum Flow (n) Maximum flow (measuring range) m3 /h
  • 7. Copyright Reserved, Zero Instrument Corporation 6 4.0 CAUTIONS FOR INSTALLATION Mounting Positions  Pipes must be fully filled with liquids. It is essential that pipes remain fully filled at all times, otherwise flow rate indications may be affected and measurement errors may be caused.  Avoid Air Bubbles. If air bubbles enter a measurement pipe, flow rate indications may be affected and measurement errors may be caused.  Avoid all pipe locations where the flow is pulsating, such as in the outlet side of piston or diaphragm pumps.  Avoid locations near equipment producing electrical interference such as electric motors, transformers, variable frequency, etc.  Install the meter with enough room for future access for maintenance purposes.  The mag meter isolating liner, whether if it is PTFE or Rubber, is not intended to be used as gasket material. Standard gaskets (not provided) should be installed to ensure a proper hydraulic seal. When installing the gaskets, make sure they are properly centered to avoid flow restriction or turbulence. Do not use graphite or any electrically conductive sealing compound to hold the gaskets in place during installation. This could affect the reading accuracy of the measuring signal. Warning: Precaution for direct sunshine and rain when the meter is installed outside. Required Lengths of Straight Runs For optimum accuracy performance, it is required to provide sufficient inlet and outlet straight pipe runs. An equivalent to 3 diameters of straight pipe is required on the inlet side, and 2 diameters on the outlet side. There are no special requirements for standard concentric pipe reducers. See diagram1 for required straight runs when there is altering device.
  • 8. Copyright Reserved, Zero Instrument Corporation 7 Diagram 1. Required straight runs Special Notice  When the meter contains removable coverplates. Leave the coverplate installed unless accessory modules specify removal. Don’t remove the coverplates when the meter is powered, or electrical shock and explosion hazard can be caused. Flange Connections The flange follows GB/T 9119-2000 (ISO 7005-1) RF (Raised Face). Note: flange can be customized following other criterias. Use a gasket between the meter flange and mating flange. Determine the material of the gasket based on the operating conditions and type of fluid.…………………………………………. Note: Do not over tighten the flange bolts. This may cause the gasket to be compressed into the flow stream and may decrease the accuracy of the meter. Installation Dimensions See Figure 1 and Table 2 for detailed dimensions. Figure 1: Drawings for Integrated/Remote Electromagnetic Flow Meter
  • 9. Copyright Reserved, Zero Instrument Corporation 8 Table 2. Dimensions (Unit: mm) Diameter DN a D Do n × Φ A 10 230 90 60 4 × 14 15 230 95 65 4 × 14 20 230 105 75 4 × 14 25 230 115 85 4 × 14 32 230 140 100 4 × 18 40 230 150 110 4 × 18 50 230 165 125 4 × 18 65 230 185 145 8 × 18 80 230 200 160 8 × 18 100 230 220 180 8 × 18 125 280 245 210 8 × 18 150 280 285 240 8 × 22 200 310 340 295 12 × 22 250 360 405 355 12 × 22 300 460 460 410 12 × 22 350 460 520 470 16 × 22 400 460 580 525 16 × 26 450 460 640 585 20 × 26 500 600 715 650 20 × 26 600 600 840 770 20 × 30 700 700 895 840 24 × 33 800 800 1015 950 24 × 33 900 900 1110 1050 28 × 33 1000 1000 1230 1160 28 × 36 1200 1200 1405 1340 32 × 33 1400 1400 1630 1560 36 × 36 1600 1600 1830 1760 40 × 36 1800 1800 2045 1970 44 × 39 2000 2000 2265 2180 48 × 42 2200 2200 2405 2315 52 × 45
  • 10. Copyright Reserved, Zero Instrument Corporation 9 5.0 ELECTRICAL WIRING Warning: Electrical Hazard Disconnect power before beginning installation. Terminal Configuration Terminal Wiring Warning: The mag flow meter is powered by EITHER 220Vac OR 24V DC. Please use right power supply or maybe cause permanent damage on meter. 6.0 PROGRAMMING AND SETUP The display panel comes preprogrammed from the factory and in most instances will not require any additional manipulation. However, if you will be using the flow signal outputs or need to reprogram the meter to suit your particular needs, it will be necessary to familiarize yourself with the programming procedures.
  • 11. 10 Figure 2. Enter Parameter and Display Panel Illustration Figure 3. Detailed Illustration for Menu - Basic
  • 12. 11 Figure 4. Detailed Illustration for Menu - System
  • 13. 12 Figure 5. Detailed Illustration for Menu – Calibration Notice: The Menu - Detail is only for factory programming, and it’s not permitted for user to change these setting in Menu – Detail. … … … … … … … … … … … … … . . .
  • 14. 13 7.0 TROUBLESHOOTING Symptom Probable Cause Solution Measurement is not accurate 1. Parameter wrong Check the parameters (Transmitter, K-factor and size) 2. Pipe is not fully filled Check if meter is fully filled Flow rate indication is unstable 1. Grounding issue Make sure meter is properly grounded to a good earth ground 2. Air Make sure fluid does not contain air bubbles 3. Converter location – outside electrical interference Make sure Converter is not too close to sources of electrical interference No Display 1. No power Apply correct power 2. Incorrect power Check power value 3. Wiring connections Check power input/output connections 4. Fuse blown Replace fuse
  • 15. 14 Limited Warranty Policy FOR NON-WARRANTY REPAIRS OR CALIBRATIONS, consult Zero Instrument for current repair/calibration charges. Have the following information available BEFORE contacting Zero Instrument: 1. P.O. number to cover the COST of the repair/calibration, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. Zero Instrument hereby provides a limited warranty against defects in materials and workmanship. This product includes a 1-year warranty. The warranty period shall begin on the date of the original new equipment purchase. Warrantor’s obligation hereunder shall be limited to repairing defective workmanship or replacing or repairing any defective parts.。。。。。。。。。。 … In the event Purchaser believes the Zero Instrument product is defective, the product must be returned to Zero Instrument, transportation prepaid by Purchaser, within the appropriate warranty period relative to the product. If Zero Instrument’s inspection determines the workmanship or materials are defective and the required maintenance has been performed and, has been properly installed and operated, the product will be either repaired or replaced, at Zero Instrument’s sole determination, free of additional charge, and the goods will be returned, transportation paid by Zero Instrument, using a transportation method selected by Zero Instrument.……………………………………………………… Prior to returning the product to Zero Instrument, Purchaser must obtain a Returned Material Authorization (RMA) Number from Zero Instrument’s Customer Service Department within 30 days after discovery of a purported breach of warranty, but not later than the warranty period; otherwise, such claims shall be deemed waived. ……… ………………………………………..... If Zero Instrument’s inspection reveals the Zero Instrument product to be free of defects in material and workmanship or such inspection reveals the goods were improperly used, improperly installed, and/or improperly selected for service intended, Zero Instrument will notify the purchaser in writing and will deliver the goods back to Purchaser upon receipt of Purchaser's written instructions and agreement to pay the cost of transportation. If Purchaser does not respond within thirty (30) days after notice from Zero Instrument, the goods will be disposed of in Zero Instrument’s discretion. Zero Instrument does not warrant the product to meet the requirements of any safety code or other jurisdiction, and Purchaser assumes all risk and liability whatsoever resulting from the use thereof, whether used singlely or in combination with other machines or apparatus. This warranty shall not apply to any Zero Instrument product or parts thereof, which have been