Dr. Ibrahim presented on various sterilization methods including physical agents like heat, radiation, and filtration as well as chemical agents like alcohols, aldehydes, and gases. The most common sterilization methods used in laboratories are moist heat using an autoclave at 121°C for 15 minutes or 134°C for 3 minutes, dry heat using a hot air oven at 160-180°C, and chemical methods using ethylene oxide or beta propiolactone gases. Proper testing of sterilization efficacy includes using chemical, mechanical, and biological indicators to confirm sterilizing conditions have been met.