1. Derek Lane – Process Automation Manager – WAGO Ltd
(Vice Chairman – PI UK)
PROFINET for IoT, IIoT and Industry 4.0
PI-UK Seminar 26th June 2019 – E+H
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
3. 3PROFIBUS UK
Internet of Things: connecting things to the Internet
.
Things in buildings, energy, homes, transportation, retail, public safety, IT and, oh yeah, industry
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
4. 4PROFIBUS UK
From taxi to
ride-sharing
From record store
to streaming
From bookstore
to e-book
From
Yellow Pages
to marketplace /
GOOGLE
New business models in the Internet age:
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
5. 5PROFIBUS UK
Industry 4.0 ….moving into a fourth Ind Revolution
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
6. 6PROFIBUS UK
Fieldbus Organizations
Technology
PROFINET
PROFIBUS
EtherNet/IP
DeviceNet
Foundation
Fieldbus
Modbus TCP
Modbus
Consortium PI ODVA
FieldComm
Group
Modbus IDA
Founded 1989 1995 1994 2002
Membership 1,487 381 369 90
Regional
Organizations
27 4 4 0
Competence Centers 54 0 0 0
Test Labs 10 3 1 1
Training Centers 28 0 8 0
Fieldbus nodes 50,900,000 4,200,000 ~2,000,000 4,200,000
Ethernet nodes 10,100,000 9,500,000 ~100,000 3,675,000
Primary Backers
Siemens,
Phoenix Contact,
GE
Rockwell
OMRON
Emerson Schneider
source:organizationwebsites,HMSresearch
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
7. 7PROFIBUS UK
IIoT is boosting Industrial Ethernet growth
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
8. 8PROFIBUS UK
Road to Industrial Ethernet
PROFIBUS PA
PROFIBUS DP
…What’s next?!
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
9. 9PROFIBUS UK
Industrial Internet of Things
IIoT
Industrie 4.0
Internet
of
Things
IoT IIoT
Revolution Evolution
Things Data
Ad hoc
connectivity
Structured
connectivity
Important –but
not critical
Mission critical
• Analytics
• Security
• Data integrity
• Response
times
User serviced User + OEM +
Vendor serviced
New
• Devices
• Standards
Existing
• Devices
• Standards
Proprietary
Solutions
Defined
Standards
Industry 4.0 (RAMI4.0)
PROFIBUS, PROFINET and IO-Link PI-UK Seminar at E+H – 26th June 2019
10. 10PROFIBUS UK
IoT IIoT
Revolution Evolution
Things Data
Ad hoc
connectivity
Structured
connectivity
Important –but
not critical
Mission critical
• Analytics
• Security
• Data integrity
• Response
times
User serviced User + OEM +
Vendor serviced
New
• Devices
• Standards
Existing
• Devices
• Standards
Proprietary
Solutions
Defined Standards
Data Access
Performance
Profiles
Proxies
Uptime
Diagnostics
Fault Tolerance
Security
Openness
Open Standard
Multi-vendor
PROFINET of Things
11. 11PROFIBUS UK
PROFINET of Things
ERP
Enterprise
Resource
Planning
Manufacturing
Execution
System
Plant
Asset
Management
MES
Interface defined in IEC62264
Production
Quality
Inventory
MaintenanceMaintenance
Interface defined by
PROFINET
PAM
Controller & Field Devices
PROFINET Devices
Controllers
Allen-Bradley
HMI
Storage & Analysis
OPC UA
PROFINET Proxies
PROFINET
OPC UA & 97 other protocols
PROFINETofThings
ERP
MES
OPC UA FDI
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
12. 12PROFIBUS UK
It’s all about the Data
…and what you do with it!
IIoT
PROFINETofThings
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
13. 13PROFIBUS UK
Data vs. Information
SecondsSub – Second
Timescale
Controller
Security
Visualization
Analytics
IT
1 1 1
0
0 1 1
0
0 1 1
1
0 1 0
1
0 1 0
0
17.80
0.064
4.529
Data
Information
I / O
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
14. 14PROFIBUS UK
Orders of magnitude – Big Data
Orders of magnitude:-
1000 kB kilobyte
10002 MB megabyte
10003 GB gigabyte
10004 TB terabyte
10005 PB petabyte
exabyte
1 EB = 10006 bytes = 1018 bytes = 1,000,000,000,000,000,000 bytes
Equal to:- 1000 petabytes
Equal to:- 1 million terabytes
Equal to:- 1 billion gigabytes.
After that:-
10007 ZB zettabyte
10008 YB yottabyte
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
15. 15PROFIBUS UK
Data Access – Performance
Use TCP/IP where it makes sense
Non time critical data
Skip TCP/IP where it doesn’t
Cyclic I/O can be taken for granted
Coexistence (ISO/OSI model)
Factory
Automation
Motion Control
Application
Standard
Communication
TCP/IP
<1ms1-10ms100ms+
Real-Time IRT
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
16. 16PROFIBUS UK
Data Access – Application Profiles
Motor Starter:
LVSG Profile
Identifying:
Ident Profile
Checking:
Weighing Profile
Filling:
Intelligent Pumps
Charging level:
PA devices
Filling:
Dosing Profile
Detecting Position:
Encoder Profile
Measuring
Temperature:
RIO for PA
Pressure:
PA devices
Protecting:
PROFIsafe
Packaging:
PROFIdrive
Palletizing:
Robots & NC Profile
Controlling:
Host Profile
Saving Energy:
PROFIenergy
Structuring data in
consistent object
format
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
17. 17PROFIBUS UK
Data Access – Proxies
Machine Machine MachineMachine
Proxy
Factory
Legacy fieldbus
network
(PROFIBUS)
Industrial
Ethernet network
(PROFINET)
Data from
Ethernet and
legacy networks
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
18. 18PROFIBUS UK
Plausible Deniability is not a Security Strategy
18
Your facility could be targeted
Your facility might be a victim,
even if not targeted
The most targeted industry is
Manufacturing!
Basics:-
Firewall & VPN (Virtual Private Network)
System “hardening”
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
19. 19PROFIBUS UK
Openness – Open Standard
Where open open standards exist…
Innovation is driven
Broad selection of products and vendors
Longer lifetime than proprietary solutions
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
20. 20PROFIBUS UK
Trends Summary
IIoT is in the intersection of IoT and Industrie 4.0
Big Data is moved via OPC UA and stored in the Cloud to be analyzed
Networks are most useful item to support IIoT
Companies are budgeting to implement IIoT
PROFINET of Things supports IIoT through
Data Access
Uptime
Open Standards
IIoT/PROFINET of Things
provide ROI
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
21. 21PROFIBUS UK
Data Access + Openness
InformationCloud
Domain specific data transfer (IO, Safety, …)
Internet Communication
Data
Internet Communication
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
22. 22PROFIBUS UK
On our way to Industrie 4.0
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
23. 23PROFIBUS UK 23PROFIBUS Nutzerorganisation e.V.(c) 2018
Industry 4.0@PNO – The near Future
Harmonized Network Infrastructure
Enhanced Robustness
Convergence of IT and OT
Multiple services on network
Gigabit Strategy
TSN
Data Semantics
Enhanced Profiles
IPv6
Easy Network Setup
F-Device Flexibility
Dynamic Interfaces
Diagnosis
Asset management
Maintenance
Device Information CloudSecurity
OPC UA
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
24. 24PROFIBUS UK 24PROFIBUS Nutzerorganisation e.V.
The promise of TSN…
Using standard chips
Plug&Work Networks
Low latency
networks
Robustness, even with
high network loads
Real time
communication
Converged
data
transport for OT and IT
(c) 2018PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
25. 25PROFIBUS UK
PROFINET uses TSN
for communication in the field
Continuity in the user view
Same services
Same engineering
Proven ecosystem
Standard Ethernet technology
Wide-ranging chip supply
GBit / IEEE continued
development
High determinism
Integrated synchronicity
Extremely rugged
Even with heavy TCP/IP traffic
PROFINET@TSN
Machine
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019 (c) 2018
26. 26PROFIBUS UK 26PROFIBUS Nutzerorganisation e.V.
Architecture PROFINET with TSN
2: Data Link Layer
1: Physical layer
3: Network layer
4 Transport layer
5-7: Session /
Presentation /
Application
RT TSN
PROFINET services
(IO, alarms, records, etc.)
100 Mbit / 1 GBit / …
IP
UDP TCP
Proven PROFINET services
Configuration, parameterization, diagnostics
Profiles: PROFIsafe, PROFIdrive, PROFIenergy,
etc.
Easy TSN network configuration
Support by runtime mechanisms
Optional topology configuration
Uniform mechanism
For isochronous and non-isochronous applications
Flexible topologies, no "island formation"
Flexibility on the physical layer
Scalable and easy to
integrate PROFINET stacks
IRT
(c) 2018PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
27. 27PROFIBUS UK 27PROFIBUS Nutzerorganisation e.V.PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019 (c) 2018
In the Future PROFINET Down to the Field Level
„2-wire“ PROFINET Field Devices
for hazardous areas
Plant Access
Point
Operator Engineering
Plant Asset
Management
Industrial Ethernet
Traditional I/O PROFIBUS PA Field Devices
PROFINET
Controller
MCC
PROFIBUS PA
PROFINET Field Devices
Remote I/O ?Proxy Switch
28. 28PROFIBUS UK 28PROFIBUS Nutzerorganisation e.V.
PROFINET Down to the Field Level in the Future
Oil & GasChemicals Power & Energy
Primaries &
Metals
“Market needs have to be
implemented for the use of
PROFINET in traditional
process industries”
Requirements:
Communication and energy
for PROFINET 2-wire field devices
Long distances
Use in the Ex area
High availability
Ease of use
“2-wire” PROFINET field device for
Ex-area
APL
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019 (c) 2018
29. 29PROFIBUS UKPROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
Technical solution – Advanced Physical Layer
(c) 2018
▪ Trunk
▪ Installation in hazardous areas Zone 1, Class 1 Div 1*
▪ cable length <= 1000m @ 10Mbps full duplex
▪ Increased Safety: communication and power <= 50 field
devices @500mW
▪ Intrinsic Safety: communication only
▪ Topologies: Ring, Line, Star (depends on powering
concept)
▪ Spur
▪ Installation in hazardous areas Zone 0, Class 1 Div 1*
▪ cable length <= 200m@10Mbps full duplex
▪ Intrinsic safety: communication with loop-power or
communication only
▪ Intrinsic Safety verification similar to FISCO
▪ 2-wire, shielded IEC61158 type A fieldbus cable
▪ APL Ethernet Switch separately powered or trunk–cable
powered (increased safety)
APL Ethernet
Field Switch
Zone 2 /Div 2
Zone 1 / Div 1
Zone 0 / Div 1
Trunk
Spur
…… …
APL Ethernet
Field Switch
100Mbps or Gbps
APL Ethernet
Power Switch
Controller
30. 30PROFIBUS UKPROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
APL will support ALL Ethernet-based Protocols
(c) 2018
1: Physical Layer
2: Data Link Layer
3: Network Layer
4: Transport Layer
5-7: Session/
Presentation/
Application Layer
Ethernet PHY
(according to IEEE 802.3 cg)
Frontend for Advanced Physical Layer
IP
TCP/UDP
Ethernet (real-time, non-real-time, TSN)
APL
ONLY
modifies
PHYSICAL Layer
The Advanced Physical Layer will not
impact the protocol stack for industrial
Ethernet networks
and
will be compatible with emerging
standards for Time Sensitive
Networking
31. 31PROFIBUS UKPROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
PI‘s Process Automation Solution
(c) 2018
PI has already components ready for the
Process Automation
APL solves the gap to use PROFINET
down to the field for hazardous
applications
✓
✓
✓
32. 32PROFIBUS UK
Machine networking with OPC UA
OPC UA
For horizontal controller /
controller communication
Cross-vendor interoperability
Procedure
1. Client/Server (TCP/IP)
2. Pub/Sub (UDP)
3. Pub/Sub on Streams (TSN)
OPC UA@TSN
Machine Machine
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019 (c) 2018
33. 33PROFIBUS UKPROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
Communication is not always unambiguous
Language
“Jaguar”
Source USFWS - U.S. Fish and Wildlife Service Digital Library System, Gemeinfrei,
https://commons.wikimedia.org/w/index.php?curid=314152Source Jaguar https://www.jaguar.de
(c) 2018
34. 34PROFIBUS UKPROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
eCl@ss offers a classification system
Language
“Jaguar”
Source Jaguar https://www.jaguar.de
Sender Receiver
Value
description
“ID”
(c) 2018
35. 35PROFIBUS UK
Mapping of PROFINET Objects into OPC UA
Providing information for Industrie 4.0 → OPC UA Companion Specs
Use Cases Asset Management and Diagnostics
Joint Working Group with OPC Foundation → Spec release expected 2019
(c) 2018
Asset
Management
Data
Record
Diagnostic
Information
Device 2
Error:…
Administration Shell Administration Shell
Machine 2Machine 1
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019
37. 37PROFIBUS UK
Thank You for your Attention !
Derek Lane – Automation Manager – WAGO Ltd
Tel:- 0044 1788 568 008
Email:- derek.lane@wago.com
(Vice Chairman – PI UK)
PROFIBUS, PROFINET and IO-Link - PI-UK Seminar at E+H – 26th June 2019