SUMMARY:
Over 25 years in the QA/QC field in various positions with Machine Shop and FDA regulated industries.
Familiar with Oscilloscopes and DVM OHM meters, Pressure gages,Thermometers, Balances/Scales
Extensive knowledge of measuring tools, including Micrometers, Verniers, Depth and Height Gauges, Optical Comparators,
CMM and various Optical Measuring equipment.
Fluent in Italian.
EMPLOYMENT
Genzyme Corporation,Framingham,Ma 2011-Present
Facilities Calibration Specialist:
Maintain all Framingham Biologics Calibration Standards and assure that all standard are in a continuous state of
compliance. Responsible for reviewing vendor calibration documentation.
Responsible for all Trackwise activities associated with Calibration Standards MDRs.
Oversee organizing all upfront documentation required to process new instruments and systems into the Framingham
Biologics Calibration Program.
Liaison between the various Framingham Biologics groups and Framingham Biologics Calibration group during
installation and calibration of new systems.
Generate department technical metrics at the require frequency, which drive accountability for productivity and
reliability of standards.
Lead and Calibration-related projects and motivate cross-functionalteams as related to job function.
Provide technical training to calibration technicians; draft appropriate OJTs for current and new systems to ensure
compliance with GMPs, Corporate Quality Standards and Dept SOPs.
Primary Representative for the following: OJT Development Team, Calibration Communities of Practice.
Crosspoint Engineering,Westwood,Ma 2010-2011
Field Calibration Technician:
Calibration of various instruments in accordance to conformance principles.
Perform all types of basic instrumentation procedures.
Routinely test instrument accuracy and make adjustments as necessary.
Routine service, troubleshooting,installation and maintenance.
Learn and utilize new methods and/orprocedures for calibration.
Maintain accurate records of equipment calibration, work order history and completion, inventory and necessary data
requirements needed,internally or externally, by client.
Review of materials/documentation to ensure all requirements are being met for GMP’s and internal company SOP’s .
ConMed Endoscopic Technologies,Chelmsford,MA 2005 –2009
Senior QA/Calibration/ComplaintTechnician
Calibration:
Measured, calibrated and certified tools and machines.
Evaluated and recommended cost effective means to calibrate. Performed a wide range of calibration and certification
functions,including developing certification and calibration procedures, day-to-day calibration of tools.
Assist Research & Development in new product development testing.
Active participant in the purchase of major capital measuring equipment.
Solely responsible for maintaining the calibration database,utilizing Calibration Recall software. Added to in-house
metrology capabilities.
Performed incoming, in-process and final inspection of machined components.
Complaints:
Evaluated products based on reason for return.
Actively participated in complaint review meetings.
Interfaced with appropriate departments within the organization on complaint trends.
Interfaced with customers during complaint investigation.
Updated appropriate complaint records using Trackwise computer program.
2. Joseph Onofaro
Page 2
Armstrong Pharmaceuticals,West Roxbury,MA 2004 – 2005
Metrology Coordinator
Scheduled and maintained the calibration of manufacturing equipment.
Maintained database, files and distributed monthly reports.
Completed, distributed and tracked reports required for calibration files.
Scheduled outside vendors for equipment requiring calibration.
Pursued improvement in compliance, accuracy and efficiency of functions, procedures and systems.
Developed process for calibration of additional assets, adding to in-house metrology capabilities.
Self employed 2002 – 2004
Performed variety of services, such as landscaping and building maintenance.
Boston Scientific Corporation,Watertown, MA 1989 - 2002
Calibration Supervisor 2001 –2002
Assessed and managed the needs of the Calibration department and provided adequate support and direction to assure
the calibration activities are appropriate.
Knowledge of advanced metrology skills, CMM and precision dimensional metrology.
Measured,calibrated and certified tools and machines.
Evaluated and recommended cost effective means to calibrate/certify.
Performed vendoraudits relative to certification and calibration services.
Senior Metrology Technician 1989 –2001
Performed a wide range of calibration and certification functions, including developing certification and calibration
procedures,day-to-day calibration of tools, as well as certification of dies, molds and associated tooling.
Responsible for effectively communicating with various R&D and manufacturing groups,worldwide across the
corporation.
Active participant in the purchase of major capital measuring equipment.
Solely responsible for maintaining a certification database of over 17,000 tools utilizing Engage software by Allen
Bradley.
Conducted calibration vendoraudits on a regular basis.
MILIT ARY EXPERIENCE
Massachusetts US Army National Guard,Lexington,MA –Sergeant
Motor Sergeant, responsible for vehicles and equipment maintenance of infantry unit.
Honorably discharged.
T RAINING and EDUCAT ION
Attended numerous courses in Calibration, Metrology, SPC, Auditing, Inspection Equipment, L.S. Starrett classes on
Calibration, measuring and tool repair, ISO 9000, ISO 9001.
Wheel Vehicle Mechanical School, United States Army; Fort Dix, New Jersey
REFERENCES – Available upon request.