International Journal of Engineering Research and Development
e-ISSN: 2278-067X, p-ISSN: 2278-800X, www.ijerd.com
Volume 9, Issue 6 (December 2013), PP. 69-75

Study of Soft-Switched Isolated DC-DC Converters for
Auxiliary Railway Supply Using DC Machine
K.Sowjanya1, T. Srinivasa Rao2, M.V.Ramana murthy 3,
1

P.G Student Scholar, Associate Professor 2, Assistant Professor 3,
1,2,3
Department of Electrical & Electronics Engineering
1,2,3
Avanti Institute of Engineering & Technology, Makavarapalem(P),Vishakhapatnam(Dt), Andhra Pradesh,
India.
Abstract:- In modern railways coaches, the electrical separation between the high voltage side and the auxiliary
equipments on the consumer side is realized by means of heavy and bulky 50-Hz Transformers. In order to
reduce the weight and size of the devices, today new power supply systems are proposed that consist in softswitched isolated dc-dc converters with a lightweight medium frequency transformer and diverse output
modules supplied by a common 600-V dc intermediate circuit. This paper aims to investigate in detail two such
solutions of isolated dc-dc converters for auxiliary railway supply where zero-current transitions are achieved
for the primary inverter switches.
Index Terms:-

Auxiliary over supply ,dc-dc converters railway traction , soft switching

I.

INTRODUCTION

Railway power supply system’s need to be expanded and operated more efficiently due to increased
transport demands on rail and increased energy economy awareness. Generally speaking, an electric railway
power supply system (RPSS) differs from a public transmission or distribution system in many ways. Briefly,
the loads of RPSSs, i.e. the trains, are moving, and the size of the loads varies with time and location. Power
consumption increases with speed, weight, acceleration, inclination (gradients) and horizontal curvature, etc.
Trains can also regenerate, when braking electrically, and then the RPSS also has moving distributed generation
sources. Moreover, it is not uncommon that the loads of the trains are so high that voltage drops in the contact
line system are much larger than what is allowed in public power grids. New power supply systems are
considered that consist of soft-switched dc-dc converters and diverse output modules supplied by a common
600-V dc intermediate circuit. The input and output sides are electrically separated by a lightweight medium
frequency (MF) transformer (typically several kilohertz). Such an approach is in keeping with other research
activities that have been going on in railway traction to substitute the low frequency transformer, commonly
used to reduce the line voltage to a level more convenient for motors, by alternative solutions, either with an
intermediate conversion stage using MF transformers (“MF topologies”) or by means of transformer less
configurations.
To enable operating at high frequency with reduced EMI and switching losses, several soft-switching
techniques for high-power isolated dc-dc converters have been proposed in the literature. These can be classified
into two groups, namely zero-voltage switching (ZVS) and zero-current-switching (ZCS), where the soft
transitions are (most often) achieved by the use of an auxiliary circuit that creates some form of inductance–
capacitance (LC) resonance. The present contribution aims to investigate two different solutions of half bridge
zero-current switching pulse-width modulation (HB-ZCS-PWM) dc-dc converters for auxiliary railway supply.
It follows previous works devoted to ZVS isolated dc-dc converters for railway applications.
The first converter topology, suggested by Al storm Transport, makes use of an auxiliary circuit somewhat
similar to that considered in, which is attached to the secondary side of the MF transformer in order to achieve
ZCS. The proposed solutions, using 6.5-kV IGBT transistors as high-voltage switches , should meet the
requirements of operating conditions listed in Table I, where the main working parameters are the input voltage,
subject to wide variations, and the output current that can vary from no load up to twice the value of the rated
current (at 3-kV nominal input).

II.

PROPOSED TOPOLOGY

The first HB-ZCS-PWM dc-dc converter topology is shown in Fig. 3. A simple auxiliary circuit
consisting of a resonant capacitor Ca and an auxiliary switch Sa is attached to the secondary side in order to
achieve ZCS for the primary switches S+ and S- .Lk refers to the leakage inductance of the transformer. D1 ~ D4
are the output rectifier diodes. , Vd, V0, and I0 are the dc input voltage, output voltage and output current,
respectively. The transformer turns ratio is denoted by m (primary to secondary). Fig. 5 shows the operational

69
Study of Soft-Switched Isolated DC-DC Converters for Auxiliary…
2𝜋

key waveforms of the converter. One cycle period T s=

𝜔𝑠

is divided into two half cycles, t0 ~ t5 and t5~ t10

because the operating principles of two half cycles are symmetric, only the first half cycle is explained. This
half-cycle is divided into five modes. For convenience of the mode analysis in the steady state, several
assumptions are made as follows. All components used in this converter have ideal characteristics; the
transformer leakage inductance will, however, not be neglected C+ ,C- and L0 are large enough to be considered
as constant voltage sources Vd/2, Vd/2 , and constant current source ,I0 respectively. Each operating mode is
simply described as follows.
Mode 1[t0 ~ t1]: In this mode, S- turns on and the power is delivered from the input to the output. This
operating mode is just the same as for a conventional hard switching PWM HB converter.
Mode 2[t1 ~ t2] : At time , the auxiliary switch Sa turns on, the resonance between Lk and Ca starts.
At ,t2 the Voltage across the resonant capacitor reaches m·Vd and the transformer secondary side current
decreases to the value Of the output current I0 . Referring to Fig. 4, the resonant voltage across Ca and the
resonant current in Lk are given
𝑚𝑉 𝑑
V c=
[1-cos(𝜔0 (t-t1))]
(1)
I2 I0 +

2
𝑚𝑉 𝑑
2𝑍0

sin(𝜔0 (t-t1))

(2)

Where ω0 =1/ (𝐿 𝐾 ∙ 𝐶 𝑎 ) and .Z0 = (𝐿 𝐾 ∙ 𝐶 𝑎 )
Mode 3[t2 ~ t3]
: At time t2, the capacitor current reverses and now must flow through the antiparallel diode of Sa. In the same time, Sa can be turned off with ZCS. The resonant capacitor is discharged
according to (1) and the secondary current decreases to zero according to (2).
Mode 4[t3 ~ t4] : At time t3, the secondary current reduces to zero and cannot change direction. The
reflected current in the primary side is cancelled in S- . The switch can therefore be turned off with ZCS at t 3 .
During this mode, the output rectifier diodes are all turned off, while the resonant capacitor C a is discharged
linearly by the output current I0.
Mode 5 [t4 ~ t5]
: At t4, the voltage across Ca reduces to Zero and the capacitor current is forced to
zero (it corresponds to area in A=B Fig. 5). The output current I 0 Freewheels through D1~D4 and the secondary
voltage Reduces to zero. Since S+ and S- are both turned off, the Primary current cannot flow and the primary
voltage is imposed to zero by the secondary. From the previous analysis, the first topology of dc-dc converter
achieves ZCS for both the primary and auxiliary switches. The operating modes during the subsequent half
cycle are symmetric to those described previously. It should be noticed that the anti-parallel diodes of the
primary switches (commercial IGBT modules) are not used during operation. Hereafter, the equations will be
normalized by using the base voltage and current
Vbase=m·Vd/2
(3)
Ibase =Vbase/Z0
(4)
Assuming that the resonant capacitor is completely discharged at , t 0+Ts/2 the steady-state output
voltage characteristics for different values of Daux and a given applied input voltage V d can be expressed as
follows:
𝐾
1
V0N =2Daux+ [(𝜶+𝜋)+IoN+
(cos𝜶+1)2]
(5)
𝜋

2𝐼0𝑁

Where the ratio ωs/ ω0 is simply denoted by K , the operational duty cycle D aux is defined from the
time delay between t0 and the turn-on of Sa , and
𝜶=arcsin(IoN)
(6)
Note that the normalized quantities are denoted by an additional subscript “ N.” For given values of the
applied input voltage and the operational duty cycle Daux , the minimum load current can be determined in
solving the following implicit expression:
1+𝑐𝑜𝑠𝛼 𝑚𝑖𝑛
I0,minN= 𝜋
(7)
𝐾

· 1−2𝐷 𝑎𝑢𝑥 −(∝ 𝑚𝑖𝑛 +𝜋)

Which expresses the voltage across Ca exactly reduces to zero at the end of a half-cycle, i.e., at .t4=t5(=t0+Ts/2)

70
Study of Soft-Switched Isolated DC-DC Converters for Auxiliary…

Fig 1 Proposed topology of HB-ZCS-PWM dc-dc converter.

III.

PRINCIPLE OF OPERATION

Resonant Components: In order to achieve ZCS for the primary switches in every load conditions, the
peak resonant current in the auxiliary circuit should be larger than the maximum output current. Therefore,
according to (2), and should satisfy
𝐿𝑘
𝐶𝑎

≤

1

𝑚𝑣 𝑑

(11)

2 𝐼0,𝑚𝑎𝑥

Where I0max is the maximum output current. Otherwise stated, for given transformer characteristics m
and Lk , the following
Condition should be adopted:
Ca ≥ Ca,min
(12)
Where
𝐼
Ca,min =4Lk ·( 0,𝑚𝑎𝑥 )2
(13)
𝑚𝑉 𝑑

71
Study of Soft-Switched Isolated DC-DC Converters for Auxiliary…
The resonant period of Lk and Ca should be limited to a reasonable part of the whole switching period. In
practice, the minimum turn on time of the primary switches S + and S- should be larger than the required turn
on time of the auxiliary switch, which is determined by the resonant period. If the resonant period is too long,
the required minimum duty cycle D will be increased. Otherwise, the ZCS condition will be lost at some
particular conditions. Usually, the resonant period should therefore be a small part of the switching period,
which can be expressed as
T0=2𝜋· 𝐿 𝑘 𝐶 𝑎 = K·Ts
(14)
Where T0 (=2𝜋/ω0) is the resonant period, T s the switching period, and represents the maximum
acceptable value of ,T0/Ts
This should be limited to a reasonable value (say 20%). Based on (12)–(14), the resonant parameters can be
calculated
And the smaller one should be adopted in the design.
2) Power Devices: The design equations reported in Table I provide suitable ratings of the power
semiconductor devices under worst case operating conditions to ensure proper operation of the converter. For
reasons of conciseness, the complete Developments of the proposed design equations cannot be exposed here.
Still these have been derived by applying the conventional definitions of the peak, average, and rms values to
the devices voltage and current idealized waveforms (deduced from the previous theoretical analysis in Section
II). Using (5) (non-normalized), the auxiliary duty cycle was also substituted with an expression in terms the
output voltage and the output current. The ratings of the devices calculated from the given design equations
provide a good approximation for the final values used in an actual implementation which, however, may be
somewhat different due to other practical considerations .The maximum and minimum peak resonant current
through the resonant capacitor Ca are defined by
𝑚 ∙𝑉
Ic,max = 𝑑,𝑚𝑎𝑥
2𝑍0

Ic,min =

𝑚 ∙𝑉 𝑑,𝑚𝑖𝑛

(15)

2𝑍0

Referring to Table II, the maximum voltage stress across both the primary and secondary power
devices occurs at the Maximum input voltage 𝑉 𝑑,𝑚𝑎𝑥 . Under the condition that the output voltage is properly
regulated, the maximum current Stress through the sec ondary side devices arises for the maximum output
current and the maximum input voltage (i.e., for The highest value of the peak resonant current). In the primary
side, it is noticed that the maximum stress in terms of average And rms currents through the primary switches,
S+ and S- , occurs at the minimum input voltage. Note that, in order to calculate the rms currents reported in
Table II, we also defined
𝐼
𝐼
𝜶1=arcsin( 0,𝑚𝑎𝑥 ) , 𝜶2=arcsin( 0,𝑚𝑎𝑥 )
(16)
𝐼 𝐶,𝑚𝑖𝑛

𝐼 𝐶,𝑚𝑎𝑥

hence, 𝝃1 =cos(𝜶1) and 𝝃2 =cos(𝜶2) .
Table I ANALYTICAL EXPRESSIONS OF THE MAXIMUM VOLTAGE AND CURRENT STRESSES OF
THE POWER DEVICES USED IN TOPOLOGY
Power Peak
Peak ,average and rms currents
devic voltage
es
S+ , S- VS ,peak =V IS,peak = m·(I0,max+Ic,max) ,IS,ave = 𝑉0 .𝐼0,𝑚𝑎𝑥 ,
𝑉 𝑑,𝑚𝑖𝑛

d,max

IS,rms =m·
Sa

VSa
,peak=

2
𝑉0 .𝐼0,𝑚𝑎𝑥

𝑚 ·𝑉 𝑑,𝑚𝑖𝑛

+

Isa,peak=IC,max, ISa,ave =

𝐾
2𝜋

2𝐾
𝜋

−

3
𝐼0,𝑚𝑎𝑥

𝐼 𝐶,𝑚𝑖𝑛

2
+ −𝜉1 + 𝜉1 + 3 ·

· 𝐼 𝐶,𝑚𝑎𝑥 , 𝐼 𝑆𝑎 ,𝑟𝑚𝑠 =

𝐾
2

𝐼0,𝑚𝑎𝑥 ·𝐼 𝐶,𝑚𝑖𝑛
2

+

𝛼 1 +𝜋
2

· 𝐼2
𝐶,𝑚𝑖𝑛

· 𝐼 𝐶,𝑚𝑎𝑥

𝑚 𝑉 𝑑 ,𝑚𝑎𝑥
2

Da
D1 ~
D4

VDa,peak
𝑚 𝑉 𝑑 ,𝑚𝑎𝑥
=
2
VD,peak
=mVd,max

IDa,peak=Io,max ,IDa,ave =ISa,ave,IDa,rms=
ID,peak =
ID,rms =

𝐼𝑆,𝑝𝑒𝑎𝑘

𝑉0
𝑚 ·𝑉 𝑑,𝑚𝑎𝑥

𝑚

+

, 𝐼 𝐷,𝑎𝑣𝑒 =
1

2
𝐼0,𝑚𝑎𝑥

2

2

+

𝐼0,𝑚𝑎𝑥
2
𝑘
4𝜋

𝐾
2𝜋

·

𝜉2 + 2 · 𝐼0,𝑚𝑎𝑥 · 𝐼 𝐶,𝑚𝑎𝑥 + 𝛼2 · 𝐼 2
𝐶,𝑚𝑎𝑥

,

−

3
𝐼0,𝑚𝑎𝑥

𝐼 𝐶,𝑚𝑎𝑥

72

2
+ 𝛼2 + 𝜋 · 2𝐼0 ,𝑚𝑎𝑥 + 𝐼 2 ,𝑚𝑎𝑥 − 3 · 𝜉2 · (𝜉2 · +1) ·
𝐶

𝐼0,𝑚𝑎𝑥 ·𝐼 𝐶,𝑚𝑎𝑥
2
Study of Soft-Switched Isolated DC-DC Converters for Auxiliary…
IV.

MATLAB MODELING AND SIMULATION RESULTS

Fig2. Matlab/Simulink Model of proposed Comparative Study of Soft-Switched Isolated DC-DCConverters for
Auxiliary Railway Supply

Fig 3. Output Voltage

Fig 4. Output Current

Fig 5 Output speed

73
Study of Soft-Switched Isolated DC-DC Converters for Auxiliary…

Fig 6 waveforms of voltage and current across transformer

Fig 7 output of pulse generator

V.

CONCLUSION

This paper has investigated topology of soft-switched isolated dc-dc converters for auxiliary railway
supply. First, the operating principles and the design considerations have been presented in detail. Then,
computer simulations have been conducted in accordance with the requirements of the specific railway
application in order to verify the theoretical analysis. The steady-state output voltage characteristics at 3-kV
input have been discussed for the topology, As an important requirement, the ability to supply 600-V output at
light loads has also been studied from these characteristics ,here dc machine is used in place of resistive load
then the output voltage is above 600v, Finally, a analysis of the topology has been carried out, the main
outcomes are as follows: 1) the overall weight and size reduction of the passive components is rather in favour
2) even though less material is expected for as regards the transformer; 3) at rated conditions, the total power
loss of the power semiconductor devices is significantly less for topology #1 (no hard-switching); 4) if the
values of the resonant elements are changed within a prescribed tolerance, the two converters are still able to
achieve ZCS;

REFERENCES
[1].
[2].
[3].
[4].

[5].

[6].

[7].

[8].

A. Steimel, “Electric railway traction in Europe,” IEEE Ind. Appl. Mag., vol. 2, no. 6, pp. 6–17, 1996.
J. Weber, A. Berger, and A. Falk, “Galvanic separated high frequency power converter for auxiliary
railway supply,” presented at the 10th Eur. Power Electron. Conf., Toulouse, France, Sep. 2003.
D. Vinnikov, J. Laugis, and T. Jalakas, “Development of auxiliary power supplies for the 3.0 kV DC
rolling stock,” in Proc. IEEE Int.Symp. Ind. Electron. (ISIE), Vigo, Spain, Jun. 2007, pp. 359–364.
D. Vinnikov and J. Laugis, “High voltage auxiliary power supply with the simplified power circuit
topology for the DC trains,” in Proc. 9th Int. Conf. Elect. Power Quality Utilisation (EPQU),
Barcelona, Spain, 2007, pp. 1–6.
T. Kjellqvist, S. Norrga, and S. Ostlund, “Design considerations for a medium frequency transformer in
a line side power conversion system,” in Proc. IEEE 35th Annu. Power Elect. Spec. Conf., Aachen,
Germany, 2004, pp. 704–71.
T. Kjellqvist, S. Norrga, and S. Ostlund, “Switching frequency limit for soft-switching MF transformer
system for AC-fed traction,” in Proc. IEEE 36th Annu. Power Elect. Spec. Conf., Recife, Brazil, 2005,
pp. 1678–1684.
A. Rufer, N. Schibli, C. Chabert, and C. Zimmermann, “Configurable front-end converters for
multicurrent locomotives operated on 16 2/3 Hz AC and 3 kV DC systems,” IEEE Trans. Power
Electron., vol. 18, no. 5, pp. 1186–1193, Sep. 2003.
B. Engel, M. Victor, G. Bachman, and A. Falk, “15 kV/16.7 Hz energy supply system with medium
frequency transformer and 6.5 kV IGBTs in resonant operation,” presented at the 10th Euro. Power
Electron. Conf., Toulouse, France, 2003.

74
Study of Soft-Switched Isolated DC-DC Converters for Auxiliary…
[9].
[10].

[11].

[12].
[13].

[14].

[15].

[16].

S. Dieckerhoff and U. Schaefer, “Transformerless drive system for main line rail vehicle propulsion,”
presented at the 9th Euro. Power Electron. Conf., Gratz, Austria, 2001.
S. Dieckerhoff, S. Bernet, and D. Krug, “Power loss-oriented evaluation of high voltage IGBTs and
multilevel onverters in transformerless traction applications,” IEEE Trans. Power Electron., vol. 20,
no. 6, pp. 1328–1329, Nov. 2005.
M. T. Aydemir, A. Bendre, and G. Venkataramanan, “A critical evaluation of high power hard and soft
switched isolated DC-DC converters,” in Proc. 37th IAS Annu. Meet. Ind. Appl. Conf., 2002, pp. 1338–
1345.
F. Z. Peng, H. Li, G.-J. Su, and J. S. Lawler, “A new ZVS bidirectional DC-DC converter for fuel cell
and battery application,” IEEE Trans. Power Electron., vol. 19, no. 1, pp. 54–65, Jan. 2004.
H. Li, F. Z. Peng, and J. S. Lawler, “A natural ZVS medium-power bidirectional DC-DC converter
with minimum number of devices,” IEEE Trans. Ind. Appl., vol. 39, no. 2, pp. 525–535, Mar./Apr.
2003.
L. Zhu, “A novel soft-commutating isolated boost full-bridge ZVS-PWM DC-DC converter for
bidirectional high power applications,” IEEE Trans. Power Electron., vol. 21, no. 2, pp. 422–429, Mar.
2006.
Q. Chongming and K. M. Smedley, “An isolated full bridge boost converter with active soft
switching,” in Proc. IEEE 32nd Annu. Power Elect. Spec. Conf., Vancouver, BC, Canada, 2001, pp.
896–903.
J. E. Baggio, H. L. Hey, and J. R. Pinheiro, “An improved full-loadrange isolated ZVS-PWM DC-DC
converter,” in Proc. 6th Annu. IEEE Appl. Power Electron. Conf. Expos., Anaheim, CA, 2001, pp.
708–714.

75

More Related Content

What's hot

HARMONIC ANALYSIS OF THREE LEVEL DIODE CLAMPED INVERTER
HARMONIC ANALYSIS OF THREE LEVEL DIODE CLAMPED INVERTERHARMONIC ANALYSIS OF THREE LEVEL DIODE CLAMPED INVERTER
HARMONIC ANALYSIS OF THREE LEVEL DIODE CLAMPED INVERTERJournal For Research
 
Simulation of Five Level Diode Clamped Multilevel Inverter
Simulation of Five Level Diode Clamped Multilevel InverterSimulation of Five Level Diode Clamped Multilevel Inverter
Simulation of Five Level Diode Clamped Multilevel Inverterrahulmonikasharma
 
A New Filtering Method and a Novel Converter Transformer for HVDC System.
A New Filtering Method and a Novel Converter Transformer for HVDC System.A New Filtering Method and a Novel Converter Transformer for HVDC System.
A New Filtering Method and a Novel Converter Transformer for HVDC System.IOSR Journals
 
Long Transmission Lines
Long Transmission LinesLong Transmission Lines
Long Transmission LinesAbha Tripathi
 
RGPV NOTES ON FACTS EX8303 unit I & II
RGPV NOTES ON FACTS EX8303 unit I & IIRGPV NOTES ON FACTS EX8303 unit I & II
RGPV NOTES ON FACTS EX8303 unit I & IIMani Deep Dutt
 
Simplified analysis of graetz circuit copy - copy
Simplified analysis of graetz circuit   copy - copySimplified analysis of graetz circuit   copy - copy
Simplified analysis of graetz circuit copy - copyVert Wheeler
 
Space Vector Modulation Strategy for NPC Converter
Space Vector Modulation Strategy for NPC ConverterSpace Vector Modulation Strategy for NPC Converter
Space Vector Modulation Strategy for NPC ConverterIRJET Journal
 
Control of hvdc system
Control of hvdc systemControl of hvdc system
Control of hvdc systemAazim Rasool
 
PWM Switched Voltage Source Inverter with Zero Neutral Point Potential
PWM Switched Voltage Source Inverter with Zero Neutral Point PotentialPWM Switched Voltage Source Inverter with Zero Neutral Point Potential
PWM Switched Voltage Source Inverter with Zero Neutral Point Potentialijsrd.com
 
Harmonic Analysis of 6-Pulse and 12-Pulse Converter Models
Harmonic Analysis of 6-Pulse and 12-Pulse Converter ModelsHarmonic Analysis of 6-Pulse and 12-Pulse Converter Models
Harmonic Analysis of 6-Pulse and 12-Pulse Converter ModelsIJMER
 
Lecture 28 360 chapter 9_ power electronics inverters
Lecture 28 360 chapter 9_  power electronics invertersLecture 28 360 chapter 9_  power electronics inverters
Lecture 28 360 chapter 9_ power electronics invertersValentino Selayan
 
RGPV Unit i ex503 - copy
RGPV Unit i ex503 - copyRGPV Unit i ex503 - copy
RGPV Unit i ex503 - copyMani Deep Dutt
 
Design of Three-Phase Three-Switch Buck-Type Rectifier for Pre-Charging Appli...
Design of Three-Phase Three-Switch Buck-Type Rectifier for Pre-Charging Appli...Design of Three-Phase Three-Switch Buck-Type Rectifier for Pre-Charging Appli...
Design of Three-Phase Three-Switch Buck-Type Rectifier for Pre-Charging Appli...IAES-IJPEDS
 
Control of HVDC Transmission System Based on MMC with Three-Level Flying Capa...
Control of HVDC Transmission System Based on MMC with Three-Level Flying Capa...Control of HVDC Transmission System Based on MMC with Three-Level Flying Capa...
Control of HVDC Transmission System Based on MMC with Three-Level Flying Capa...Anand Parakkat Parambil
 
RGPV BE Ist SEM BEE104 Unit I
RGPV BE Ist SEM BEE104 Unit IRGPV BE Ist SEM BEE104 Unit I
RGPV BE Ist SEM BEE104 Unit IMani Deep Dutt
 

What's hot (20)

HARMONIC ANALYSIS OF THREE LEVEL DIODE CLAMPED INVERTER
HARMONIC ANALYSIS OF THREE LEVEL DIODE CLAMPED INVERTERHARMONIC ANALYSIS OF THREE LEVEL DIODE CLAMPED INVERTER
HARMONIC ANALYSIS OF THREE LEVEL DIODE CLAMPED INVERTER
 
Simulation of Five Level Diode Clamped Multilevel Inverter
Simulation of Five Level Diode Clamped Multilevel InverterSimulation of Five Level Diode Clamped Multilevel Inverter
Simulation of Five Level Diode Clamped Multilevel Inverter
 
A New Filtering Method and a Novel Converter Transformer for HVDC System.
A New Filtering Method and a Novel Converter Transformer for HVDC System.A New Filtering Method and a Novel Converter Transformer for HVDC System.
A New Filtering Method and a Novel Converter Transformer for HVDC System.
 
RGPV EX7102 UNITIII
RGPV EX7102 UNITIIIRGPV EX7102 UNITIII
RGPV EX7102 UNITIII
 
Long Transmission Lines
Long Transmission LinesLong Transmission Lines
Long Transmission Lines
 
RGPV NOTES ON FACTS EX8303 unit I & II
RGPV NOTES ON FACTS EX8303 unit I & IIRGPV NOTES ON FACTS EX8303 unit I & II
RGPV NOTES ON FACTS EX8303 unit I & II
 
Simplified analysis of graetz circuit copy - copy
Simplified analysis of graetz circuit   copy - copySimplified analysis of graetz circuit   copy - copy
Simplified analysis of graetz circuit copy - copy
 
Space Vector Modulation Strategy for NPC Converter
Space Vector Modulation Strategy for NPC ConverterSpace Vector Modulation Strategy for NPC Converter
Space Vector Modulation Strategy for NPC Converter
 
RGPV EX7102 unit I
RGPV EX7102 unit IRGPV EX7102 unit I
RGPV EX7102 unit I
 
Control of hvdc system
Control of hvdc systemControl of hvdc system
Control of hvdc system
 
PWM Switched Voltage Source Inverter with Zero Neutral Point Potential
PWM Switched Voltage Source Inverter with Zero Neutral Point PotentialPWM Switched Voltage Source Inverter with Zero Neutral Point Potential
PWM Switched Voltage Source Inverter with Zero Neutral Point Potential
 
Harmonic Analysis of 6-Pulse and 12-Pulse Converter Models
Harmonic Analysis of 6-Pulse and 12-Pulse Converter ModelsHarmonic Analysis of 6-Pulse and 12-Pulse Converter Models
Harmonic Analysis of 6-Pulse and 12-Pulse Converter Models
 
Lecture 28 360 chapter 9_ power electronics inverters
Lecture 28 360 chapter 9_  power electronics invertersLecture 28 360 chapter 9_  power electronics inverters
Lecture 28 360 chapter 9_ power electronics inverters
 
[IJET V2I5P10] Authors: Vinith Das, Dr. Babu Paul, Prof. Elizabeth Seba stian
[IJET V2I5P10] Authors: Vinith Das, Dr. Babu Paul, Prof. Elizabeth Seba stian [IJET V2I5P10] Authors: Vinith Das, Dr. Babu Paul, Prof. Elizabeth Seba stian
[IJET V2I5P10] Authors: Vinith Das, Dr. Babu Paul, Prof. Elizabeth Seba stian
 
[IJET V2I5P12] Authors: Mr. Harikrishnan U, Dr. Bos Mathew Jos, Mr.Thomas P R...
[IJET V2I5P12] Authors: Mr. Harikrishnan U, Dr. Bos Mathew Jos, Mr.Thomas P R...[IJET V2I5P12] Authors: Mr. Harikrishnan U, Dr. Bos Mathew Jos, Mr.Thomas P R...
[IJET V2I5P12] Authors: Mr. Harikrishnan U, Dr. Bos Mathew Jos, Mr.Thomas P R...
 
RGPV Unit i ex503 - copy
RGPV Unit i ex503 - copyRGPV Unit i ex503 - copy
RGPV Unit i ex503 - copy
 
Design of Three-Phase Three-Switch Buck-Type Rectifier for Pre-Charging Appli...
Design of Three-Phase Three-Switch Buck-Type Rectifier for Pre-Charging Appli...Design of Three-Phase Three-Switch Buck-Type Rectifier for Pre-Charging Appli...
Design of Three-Phase Three-Switch Buck-Type Rectifier for Pre-Charging Appli...
 
Control of HVDC Transmission System Based on MMC with Three-Level Flying Capa...
Control of HVDC Transmission System Based on MMC with Three-Level Flying Capa...Control of HVDC Transmission System Based on MMC with Three-Level Flying Capa...
Control of HVDC Transmission System Based on MMC with Three-Level Flying Capa...
 
RGPV BE 104 Unit II
RGPV BE 104 Unit IIRGPV BE 104 Unit II
RGPV BE 104 Unit II
 
RGPV BE Ist SEM BEE104 Unit I
RGPV BE Ist SEM BEE104 Unit IRGPV BE Ist SEM BEE104 Unit I
RGPV BE Ist SEM BEE104 Unit I
 

Similar to International Journal of Engineering Research and Development

Soft-Switching SiC Interleaved Boost Converter
Soft-Switching SiC Interleaved Boost ConverterSoft-Switching SiC Interleaved Boost Converter
Soft-Switching SiC Interleaved Boost ConverterPower System Operation
 
The International Journal of Engineering and Science (The IJES)
The International Journal of Engineering and Science (The IJES)The International Journal of Engineering and Science (The IJES)
The International Journal of Engineering and Science (The IJES)theijes
 
Single-Input Double Output High Efficient Boost Dc–Dc Converter
Single-Input Double Output High Efficient Boost Dc–Dc ConverterSingle-Input Double Output High Efficient Boost Dc–Dc Converter
Single-Input Double Output High Efficient Boost Dc–Dc ConverterIJMER
 
Quasi-Single-Stage_Current-Fed_Resonant_AC-DC_Converter_Having_Improved_Heat_...
Quasi-Single-Stage_Current-Fed_Resonant_AC-DC_Converter_Having_Improved_Heat_...Quasi-Single-Stage_Current-Fed_Resonant_AC-DC_Converter_Having_Improved_Heat_...
Quasi-Single-Stage_Current-Fed_Resonant_AC-DC_Converter_Having_Improved_Heat_...Engnr Kami Zeb
 
Soft-Switching Two-Switch Resonant AC-DC Converter
Soft-Switching Two-Switch Resonant AC-DC ConverterSoft-Switching Two-Switch Resonant AC-DC Converter
Soft-Switching Two-Switch Resonant AC-DC ConverterIRJET Journal
 
A New Single-Stage Multilevel Type Full-Bridge Converter Applied to closed lo...
A New Single-Stage Multilevel Type Full-Bridge Converter Applied to closed lo...A New Single-Stage Multilevel Type Full-Bridge Converter Applied to closed lo...
A New Single-Stage Multilevel Type Full-Bridge Converter Applied to closed lo...IOSR Journals
 
Soft Switched Multi-Output Flyback Converter with Voltage Doubler
Soft Switched Multi-Output Flyback Converter with Voltage DoublerSoft Switched Multi-Output Flyback Converter with Voltage Doubler
Soft Switched Multi-Output Flyback Converter with Voltage DoublerIJPEDS-IAES
 
Simulation of SPWM based Z-Source Inverter
Simulation of SPWM based Z-Source InverterSimulation of SPWM based Z-Source Inverter
Simulation of SPWM based Z-Source InverterIOSR Journals
 
A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...
A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...
A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...IDES Editor
 
Comparative Evaluation of Three Phase Three Level Neutral Point Clamped Z-So...
Comparative Evaluation of Three Phase Three Level  Neutral Point Clamped Z-So...Comparative Evaluation of Three Phase Three Level  Neutral Point Clamped Z-So...
Comparative Evaluation of Three Phase Three Level Neutral Point Clamped Z-So...NAGARAJARAOS
 
A Review to AC Modeling and Transfer Function of DCDC Converters
A Review to AC Modeling and Transfer Function of DCDC ConvertersA Review to AC Modeling and Transfer Function of DCDC Converters
A Review to AC Modeling and Transfer Function of DCDC ConvertersRadita Apriana
 
Microcontroller Based Novel Dc-to-Ac Grid Connected Inverter Topology
Microcontroller Based Novel Dc-to-Ac Grid Connected Inverter TopologyMicrocontroller Based Novel Dc-to-Ac Grid Connected Inverter Topology
Microcontroller Based Novel Dc-to-Ac Grid Connected Inverter TopologyIDES Editor
 

Similar to International Journal of Engineering Research and Development (20)

Soft-Switching SiC Interleaved Boost Converter
Soft-Switching SiC Interleaved Boost ConverterSoft-Switching SiC Interleaved Boost Converter
Soft-Switching SiC Interleaved Boost Converter
 
RESEARCH EXPLORER -2 ISSUE
RESEARCH EXPLORER -2 ISSUERESEARCH EXPLORER -2 ISSUE
RESEARCH EXPLORER -2 ISSUE
 
The International Journal of Engineering and Science (The IJES)
The International Journal of Engineering and Science (The IJES)The International Journal of Engineering and Science (The IJES)
The International Journal of Engineering and Science (The IJES)
 
Single-Input Double Output High Efficient Boost Dc–Dc Converter
Single-Input Double Output High Efficient Boost Dc–Dc ConverterSingle-Input Double Output High Efficient Boost Dc–Dc Converter
Single-Input Double Output High Efficient Boost Dc–Dc Converter
 
Quasi-Single-Stage_Current-Fed_Resonant_AC-DC_Converter_Having_Improved_Heat_...
Quasi-Single-Stage_Current-Fed_Resonant_AC-DC_Converter_Having_Improved_Heat_...Quasi-Single-Stage_Current-Fed_Resonant_AC-DC_Converter_Having_Improved_Heat_...
Quasi-Single-Stage_Current-Fed_Resonant_AC-DC_Converter_Having_Improved_Heat_...
 
Soft-Switching Two-Switch Resonant AC-DC Converter
Soft-Switching Two-Switch Resonant AC-DC ConverterSoft-Switching Two-Switch Resonant AC-DC Converter
Soft-Switching Two-Switch Resonant AC-DC Converter
 
N367984
N367984N367984
N367984
 
A New Single-Stage Multilevel Type Full-Bridge Converter Applied to closed lo...
A New Single-Stage Multilevel Type Full-Bridge Converter Applied to closed lo...A New Single-Stage Multilevel Type Full-Bridge Converter Applied to closed lo...
A New Single-Stage Multilevel Type Full-Bridge Converter Applied to closed lo...
 
C1103022832
C1103022832C1103022832
C1103022832
 
Soft Switched Multi-Output Flyback Converter with Voltage Doubler
Soft Switched Multi-Output Flyback Converter with Voltage DoublerSoft Switched Multi-Output Flyback Converter with Voltage Doubler
Soft Switched Multi-Output Flyback Converter with Voltage Doubler
 
M1028993
M1028993M1028993
M1028993
 
www.ijerd.com
www.ijerd.comwww.ijerd.com
www.ijerd.com
 
Simulation of SPWM based Z-Source Inverter
Simulation of SPWM based Z-Source InverterSimulation of SPWM based Z-Source Inverter
Simulation of SPWM based Z-Source Inverter
 
Lb3419962001
Lb3419962001Lb3419962001
Lb3419962001
 
15 47-58
15 47-5815 47-58
15 47-58
 
A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...
A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...
A Single-Stage High-Frequency Isolated Secondary- Side Controlled AC-DC Conve...
 
Comparative Evaluation of Three Phase Three Level Neutral Point Clamped Z-So...
Comparative Evaluation of Three Phase Three Level  Neutral Point Clamped Z-So...Comparative Evaluation of Three Phase Three Level  Neutral Point Clamped Z-So...
Comparative Evaluation of Three Phase Three Level Neutral Point Clamped Z-So...
 
Antony2015
Antony2015Antony2015
Antony2015
 
A Review to AC Modeling and Transfer Function of DCDC Converters
A Review to AC Modeling and Transfer Function of DCDC ConvertersA Review to AC Modeling and Transfer Function of DCDC Converters
A Review to AC Modeling and Transfer Function of DCDC Converters
 
Microcontroller Based Novel Dc-to-Ac Grid Connected Inverter Topology
Microcontroller Based Novel Dc-to-Ac Grid Connected Inverter TopologyMicrocontroller Based Novel Dc-to-Ac Grid Connected Inverter Topology
Microcontroller Based Novel Dc-to-Ac Grid Connected Inverter Topology
 

More from IJERD Editor

A Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
A Novel Method for Prevention of Bandwidth Distributed Denial of Service AttacksA Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
A Novel Method for Prevention of Bandwidth Distributed Denial of Service AttacksIJERD Editor
 
MEMS MICROPHONE INTERFACE
MEMS MICROPHONE INTERFACEMEMS MICROPHONE INTERFACE
MEMS MICROPHONE INTERFACEIJERD Editor
 
Influence of tensile behaviour of slab on the structural Behaviour of shear c...
Influence of tensile behaviour of slab on the structural Behaviour of shear c...Influence of tensile behaviour of slab on the structural Behaviour of shear c...
Influence of tensile behaviour of slab on the structural Behaviour of shear c...IJERD Editor
 
Gold prospecting using Remote Sensing ‘A case study of Sudan’
Gold prospecting using Remote Sensing ‘A case study of Sudan’Gold prospecting using Remote Sensing ‘A case study of Sudan’
Gold prospecting using Remote Sensing ‘A case study of Sudan’IJERD Editor
 
Reducing Corrosion Rate by Welding Design
Reducing Corrosion Rate by Welding DesignReducing Corrosion Rate by Welding Design
Reducing Corrosion Rate by Welding DesignIJERD Editor
 
Router 1X3 – RTL Design and Verification
Router 1X3 – RTL Design and VerificationRouter 1X3 – RTL Design and Verification
Router 1X3 – RTL Design and VerificationIJERD Editor
 
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...IJERD Editor
 
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVRMitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVRIJERD Editor
 
Study on the Fused Deposition Modelling In Additive Manufacturing
Study on the Fused Deposition Modelling In Additive ManufacturingStudy on the Fused Deposition Modelling In Additive Manufacturing
Study on the Fused Deposition Modelling In Additive ManufacturingIJERD Editor
 
Spyware triggering system by particular string value
Spyware triggering system by particular string valueSpyware triggering system by particular string value
Spyware triggering system by particular string valueIJERD Editor
 
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...IJERD Editor
 
Secure Image Transmission for Cloud Storage System Using Hybrid Scheme
Secure Image Transmission for Cloud Storage System Using Hybrid SchemeSecure Image Transmission for Cloud Storage System Using Hybrid Scheme
Secure Image Transmission for Cloud Storage System Using Hybrid SchemeIJERD Editor
 
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...IJERD Editor
 
Gesture Gaming on the World Wide Web Using an Ordinary Web Camera
Gesture Gaming on the World Wide Web Using an Ordinary Web CameraGesture Gaming on the World Wide Web Using an Ordinary Web Camera
Gesture Gaming on the World Wide Web Using an Ordinary Web CameraIJERD Editor
 
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...IJERD Editor
 
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...IJERD Editor
 
Moon-bounce: A Boon for VHF Dxing
Moon-bounce: A Boon for VHF DxingMoon-bounce: A Boon for VHF Dxing
Moon-bounce: A Boon for VHF DxingIJERD Editor
 
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...IJERD Editor
 
Importance of Measurements in Smart Grid
Importance of Measurements in Smart GridImportance of Measurements in Smart Grid
Importance of Measurements in Smart GridIJERD Editor
 
Study of Macro level Properties of SCC using GGBS and Lime stone powder
Study of Macro level Properties of SCC using GGBS and Lime stone powderStudy of Macro level Properties of SCC using GGBS and Lime stone powder
Study of Macro level Properties of SCC using GGBS and Lime stone powderIJERD Editor
 

More from IJERD Editor (20)

A Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
A Novel Method for Prevention of Bandwidth Distributed Denial of Service AttacksA Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
A Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
 
MEMS MICROPHONE INTERFACE
MEMS MICROPHONE INTERFACEMEMS MICROPHONE INTERFACE
MEMS MICROPHONE INTERFACE
 
Influence of tensile behaviour of slab on the structural Behaviour of shear c...
Influence of tensile behaviour of slab on the structural Behaviour of shear c...Influence of tensile behaviour of slab on the structural Behaviour of shear c...
Influence of tensile behaviour of slab on the structural Behaviour of shear c...
 
Gold prospecting using Remote Sensing ‘A case study of Sudan’
Gold prospecting using Remote Sensing ‘A case study of Sudan’Gold prospecting using Remote Sensing ‘A case study of Sudan’
Gold prospecting using Remote Sensing ‘A case study of Sudan’
 
Reducing Corrosion Rate by Welding Design
Reducing Corrosion Rate by Welding DesignReducing Corrosion Rate by Welding Design
Reducing Corrosion Rate by Welding Design
 
Router 1X3 – RTL Design and Verification
Router 1X3 – RTL Design and VerificationRouter 1X3 – RTL Design and Verification
Router 1X3 – RTL Design and Verification
 
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...
 
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVRMitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
 
Study on the Fused Deposition Modelling In Additive Manufacturing
Study on the Fused Deposition Modelling In Additive ManufacturingStudy on the Fused Deposition Modelling In Additive Manufacturing
Study on the Fused Deposition Modelling In Additive Manufacturing
 
Spyware triggering system by particular string value
Spyware triggering system by particular string valueSpyware triggering system by particular string value
Spyware triggering system by particular string value
 
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...
 
Secure Image Transmission for Cloud Storage System Using Hybrid Scheme
Secure Image Transmission for Cloud Storage System Using Hybrid SchemeSecure Image Transmission for Cloud Storage System Using Hybrid Scheme
Secure Image Transmission for Cloud Storage System Using Hybrid Scheme
 
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...
 
Gesture Gaming on the World Wide Web Using an Ordinary Web Camera
Gesture Gaming on the World Wide Web Using an Ordinary Web CameraGesture Gaming on the World Wide Web Using an Ordinary Web Camera
Gesture Gaming on the World Wide Web Using an Ordinary Web Camera
 
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
 
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
 
Moon-bounce: A Boon for VHF Dxing
Moon-bounce: A Boon for VHF DxingMoon-bounce: A Boon for VHF Dxing
Moon-bounce: A Boon for VHF Dxing
 
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...
 
Importance of Measurements in Smart Grid
Importance of Measurements in Smart GridImportance of Measurements in Smart Grid
Importance of Measurements in Smart Grid
 
Study of Macro level Properties of SCC using GGBS and Lime stone powder
Study of Macro level Properties of SCC using GGBS and Lime stone powderStudy of Macro level Properties of SCC using GGBS and Lime stone powder
Study of Macro level Properties of SCC using GGBS and Lime stone powder
 

Recently uploaded

Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfpollardmorgan
 
Eni 2024 1Q Results - 24.04.24 business.
Eni 2024 1Q Results - 24.04.24 business.Eni 2024 1Q Results - 24.04.24 business.
Eni 2024 1Q Results - 24.04.24 business.Eni
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessAggregage
 
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999Tina Ji
 
RE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechRE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechNewman George Leech
 
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsCash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsApsara Of India
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewasmakika9823
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communicationskarancommunications
 
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Roomdivyansh0kumar0
 
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear RegressionRavindra Nath Shukla
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...lizamodels9
 
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...lizamodels9
 
GD Birla and his contribution in management
GD Birla and his contribution in managementGD Birla and his contribution in management
GD Birla and his contribution in managementchhavia330
 

Recently uploaded (20)

Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
 
Eni 2024 1Q Results - 24.04.24 business.
Eni 2024 1Q Results - 24.04.24 business.Eni 2024 1Q Results - 24.04.24 business.
Eni 2024 1Q Results - 24.04.24 business.
 
KestrelPro Flyer Japan IT Week 2024 (English)
KestrelPro Flyer Japan IT Week 2024 (English)KestrelPro Flyer Japan IT Week 2024 (English)
KestrelPro Flyer Japan IT Week 2024 (English)
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for Success
 
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
Russian Faridabad Call Girls(Badarpur) : ☎ 8168257667, @4999
 
RE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechRE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman Leech
 
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsCash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communications
 
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
 
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Pune Just Call 9907093804 Top Class Call Girl Service Available
 
Forklift Operations: Safety through Cartoons
Forklift Operations: Safety through CartoonsForklift Operations: Safety through Cartoons
Forklift Operations: Safety through Cartoons
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear Regression
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
 
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
 
GD Birla and his contribution in management
GD Birla and his contribution in managementGD Birla and his contribution in management
GD Birla and his contribution in management
 

International Journal of Engineering Research and Development

  • 1. International Journal of Engineering Research and Development e-ISSN: 2278-067X, p-ISSN: 2278-800X, www.ijerd.com Volume 9, Issue 6 (December 2013), PP. 69-75 Study of Soft-Switched Isolated DC-DC Converters for Auxiliary Railway Supply Using DC Machine K.Sowjanya1, T. Srinivasa Rao2, M.V.Ramana murthy 3, 1 P.G Student Scholar, Associate Professor 2, Assistant Professor 3, 1,2,3 Department of Electrical & Electronics Engineering 1,2,3 Avanti Institute of Engineering & Technology, Makavarapalem(P),Vishakhapatnam(Dt), Andhra Pradesh, India. Abstract:- In modern railways coaches, the electrical separation between the high voltage side and the auxiliary equipments on the consumer side is realized by means of heavy and bulky 50-Hz Transformers. In order to reduce the weight and size of the devices, today new power supply systems are proposed that consist in softswitched isolated dc-dc converters with a lightweight medium frequency transformer and diverse output modules supplied by a common 600-V dc intermediate circuit. This paper aims to investigate in detail two such solutions of isolated dc-dc converters for auxiliary railway supply where zero-current transitions are achieved for the primary inverter switches. Index Terms:- Auxiliary over supply ,dc-dc converters railway traction , soft switching I. INTRODUCTION Railway power supply system’s need to be expanded and operated more efficiently due to increased transport demands on rail and increased energy economy awareness. Generally speaking, an electric railway power supply system (RPSS) differs from a public transmission or distribution system in many ways. Briefly, the loads of RPSSs, i.e. the trains, are moving, and the size of the loads varies with time and location. Power consumption increases with speed, weight, acceleration, inclination (gradients) and horizontal curvature, etc. Trains can also regenerate, when braking electrically, and then the RPSS also has moving distributed generation sources. Moreover, it is not uncommon that the loads of the trains are so high that voltage drops in the contact line system are much larger than what is allowed in public power grids. New power supply systems are considered that consist of soft-switched dc-dc converters and diverse output modules supplied by a common 600-V dc intermediate circuit. The input and output sides are electrically separated by a lightweight medium frequency (MF) transformer (typically several kilohertz). Such an approach is in keeping with other research activities that have been going on in railway traction to substitute the low frequency transformer, commonly used to reduce the line voltage to a level more convenient for motors, by alternative solutions, either with an intermediate conversion stage using MF transformers (“MF topologies”) or by means of transformer less configurations. To enable operating at high frequency with reduced EMI and switching losses, several soft-switching techniques for high-power isolated dc-dc converters have been proposed in the literature. These can be classified into two groups, namely zero-voltage switching (ZVS) and zero-current-switching (ZCS), where the soft transitions are (most often) achieved by the use of an auxiliary circuit that creates some form of inductance– capacitance (LC) resonance. The present contribution aims to investigate two different solutions of half bridge zero-current switching pulse-width modulation (HB-ZCS-PWM) dc-dc converters for auxiliary railway supply. It follows previous works devoted to ZVS isolated dc-dc converters for railway applications. The first converter topology, suggested by Al storm Transport, makes use of an auxiliary circuit somewhat similar to that considered in, which is attached to the secondary side of the MF transformer in order to achieve ZCS. The proposed solutions, using 6.5-kV IGBT transistors as high-voltage switches , should meet the requirements of operating conditions listed in Table I, where the main working parameters are the input voltage, subject to wide variations, and the output current that can vary from no load up to twice the value of the rated current (at 3-kV nominal input). II. PROPOSED TOPOLOGY The first HB-ZCS-PWM dc-dc converter topology is shown in Fig. 3. A simple auxiliary circuit consisting of a resonant capacitor Ca and an auxiliary switch Sa is attached to the secondary side in order to achieve ZCS for the primary switches S+ and S- .Lk refers to the leakage inductance of the transformer. D1 ~ D4 are the output rectifier diodes. , Vd, V0, and I0 are the dc input voltage, output voltage and output current, respectively. The transformer turns ratio is denoted by m (primary to secondary). Fig. 5 shows the operational 69
  • 2. Study of Soft-Switched Isolated DC-DC Converters for Auxiliary… 2𝜋 key waveforms of the converter. One cycle period T s= 𝜔𝑠 is divided into two half cycles, t0 ~ t5 and t5~ t10 because the operating principles of two half cycles are symmetric, only the first half cycle is explained. This half-cycle is divided into five modes. For convenience of the mode analysis in the steady state, several assumptions are made as follows. All components used in this converter have ideal characteristics; the transformer leakage inductance will, however, not be neglected C+ ,C- and L0 are large enough to be considered as constant voltage sources Vd/2, Vd/2 , and constant current source ,I0 respectively. Each operating mode is simply described as follows. Mode 1[t0 ~ t1]: In this mode, S- turns on and the power is delivered from the input to the output. This operating mode is just the same as for a conventional hard switching PWM HB converter. Mode 2[t1 ~ t2] : At time , the auxiliary switch Sa turns on, the resonance between Lk and Ca starts. At ,t2 the Voltage across the resonant capacitor reaches m·Vd and the transformer secondary side current decreases to the value Of the output current I0 . Referring to Fig. 4, the resonant voltage across Ca and the resonant current in Lk are given 𝑚𝑉 𝑑 V c= [1-cos(𝜔0 (t-t1))] (1) I2 I0 + 2 𝑚𝑉 𝑑 2𝑍0 sin(𝜔0 (t-t1)) (2) Where ω0 =1/ (𝐿 𝐾 ∙ 𝐶 𝑎 ) and .Z0 = (𝐿 𝐾 ∙ 𝐶 𝑎 ) Mode 3[t2 ~ t3] : At time t2, the capacitor current reverses and now must flow through the antiparallel diode of Sa. In the same time, Sa can be turned off with ZCS. The resonant capacitor is discharged according to (1) and the secondary current decreases to zero according to (2). Mode 4[t3 ~ t4] : At time t3, the secondary current reduces to zero and cannot change direction. The reflected current in the primary side is cancelled in S- . The switch can therefore be turned off with ZCS at t 3 . During this mode, the output rectifier diodes are all turned off, while the resonant capacitor C a is discharged linearly by the output current I0. Mode 5 [t4 ~ t5] : At t4, the voltage across Ca reduces to Zero and the capacitor current is forced to zero (it corresponds to area in A=B Fig. 5). The output current I 0 Freewheels through D1~D4 and the secondary voltage Reduces to zero. Since S+ and S- are both turned off, the Primary current cannot flow and the primary voltage is imposed to zero by the secondary. From the previous analysis, the first topology of dc-dc converter achieves ZCS for both the primary and auxiliary switches. The operating modes during the subsequent half cycle are symmetric to those described previously. It should be noticed that the anti-parallel diodes of the primary switches (commercial IGBT modules) are not used during operation. Hereafter, the equations will be normalized by using the base voltage and current Vbase=m·Vd/2 (3) Ibase =Vbase/Z0 (4) Assuming that the resonant capacitor is completely discharged at , t 0+Ts/2 the steady-state output voltage characteristics for different values of Daux and a given applied input voltage V d can be expressed as follows: 𝐾 1 V0N =2Daux+ [(𝜶+𝜋)+IoN+ (cos𝜶+1)2] (5) 𝜋 2𝐼0𝑁 Where the ratio ωs/ ω0 is simply denoted by K , the operational duty cycle D aux is defined from the time delay between t0 and the turn-on of Sa , and 𝜶=arcsin(IoN) (6) Note that the normalized quantities are denoted by an additional subscript “ N.” For given values of the applied input voltage and the operational duty cycle Daux , the minimum load current can be determined in solving the following implicit expression: 1+𝑐𝑜𝑠𝛼 𝑚𝑖𝑛 I0,minN= 𝜋 (7) 𝐾 · 1−2𝐷 𝑎𝑢𝑥 −(∝ 𝑚𝑖𝑛 +𝜋) Which expresses the voltage across Ca exactly reduces to zero at the end of a half-cycle, i.e., at .t4=t5(=t0+Ts/2) 70
  • 3. Study of Soft-Switched Isolated DC-DC Converters for Auxiliary… Fig 1 Proposed topology of HB-ZCS-PWM dc-dc converter. III. PRINCIPLE OF OPERATION Resonant Components: In order to achieve ZCS for the primary switches in every load conditions, the peak resonant current in the auxiliary circuit should be larger than the maximum output current. Therefore, according to (2), and should satisfy 𝐿𝑘 𝐶𝑎 ≤ 1 𝑚𝑣 𝑑 (11) 2 𝐼0,𝑚𝑎𝑥 Where I0max is the maximum output current. Otherwise stated, for given transformer characteristics m and Lk , the following Condition should be adopted: Ca ≥ Ca,min (12) Where 𝐼 Ca,min =4Lk ·( 0,𝑚𝑎𝑥 )2 (13) 𝑚𝑉 𝑑 71
  • 4. Study of Soft-Switched Isolated DC-DC Converters for Auxiliary… The resonant period of Lk and Ca should be limited to a reasonable part of the whole switching period. In practice, the minimum turn on time of the primary switches S + and S- should be larger than the required turn on time of the auxiliary switch, which is determined by the resonant period. If the resonant period is too long, the required minimum duty cycle D will be increased. Otherwise, the ZCS condition will be lost at some particular conditions. Usually, the resonant period should therefore be a small part of the switching period, which can be expressed as T0=2𝜋· 𝐿 𝑘 𝐶 𝑎 = K·Ts (14) Where T0 (=2𝜋/ω0) is the resonant period, T s the switching period, and represents the maximum acceptable value of ,T0/Ts This should be limited to a reasonable value (say 20%). Based on (12)–(14), the resonant parameters can be calculated And the smaller one should be adopted in the design. 2) Power Devices: The design equations reported in Table I provide suitable ratings of the power semiconductor devices under worst case operating conditions to ensure proper operation of the converter. For reasons of conciseness, the complete Developments of the proposed design equations cannot be exposed here. Still these have been derived by applying the conventional definitions of the peak, average, and rms values to the devices voltage and current idealized waveforms (deduced from the previous theoretical analysis in Section II). Using (5) (non-normalized), the auxiliary duty cycle was also substituted with an expression in terms the output voltage and the output current. The ratings of the devices calculated from the given design equations provide a good approximation for the final values used in an actual implementation which, however, may be somewhat different due to other practical considerations .The maximum and minimum peak resonant current through the resonant capacitor Ca are defined by 𝑚 ∙𝑉 Ic,max = 𝑑,𝑚𝑎𝑥 2𝑍0 Ic,min = 𝑚 ∙𝑉 𝑑,𝑚𝑖𝑛 (15) 2𝑍0 Referring to Table II, the maximum voltage stress across both the primary and secondary power devices occurs at the Maximum input voltage 𝑉 𝑑,𝑚𝑎𝑥 . Under the condition that the output voltage is properly regulated, the maximum current Stress through the sec ondary side devices arises for the maximum output current and the maximum input voltage (i.e., for The highest value of the peak resonant current). In the primary side, it is noticed that the maximum stress in terms of average And rms currents through the primary switches, S+ and S- , occurs at the minimum input voltage. Note that, in order to calculate the rms currents reported in Table II, we also defined 𝐼 𝐼 𝜶1=arcsin( 0,𝑚𝑎𝑥 ) , 𝜶2=arcsin( 0,𝑚𝑎𝑥 ) (16) 𝐼 𝐶,𝑚𝑖𝑛 𝐼 𝐶,𝑚𝑎𝑥 hence, 𝝃1 =cos(𝜶1) and 𝝃2 =cos(𝜶2) . Table I ANALYTICAL EXPRESSIONS OF THE MAXIMUM VOLTAGE AND CURRENT STRESSES OF THE POWER DEVICES USED IN TOPOLOGY Power Peak Peak ,average and rms currents devic voltage es S+ , S- VS ,peak =V IS,peak = m·(I0,max+Ic,max) ,IS,ave = 𝑉0 .𝐼0,𝑚𝑎𝑥 , 𝑉 𝑑,𝑚𝑖𝑛 d,max IS,rms =m· Sa VSa ,peak= 2 𝑉0 .𝐼0,𝑚𝑎𝑥 𝑚 ·𝑉 𝑑,𝑚𝑖𝑛 + Isa,peak=IC,max, ISa,ave = 𝐾 2𝜋 2𝐾 𝜋 − 3 𝐼0,𝑚𝑎𝑥 𝐼 𝐶,𝑚𝑖𝑛 2 + −𝜉1 + 𝜉1 + 3 · · 𝐼 𝐶,𝑚𝑎𝑥 , 𝐼 𝑆𝑎 ,𝑟𝑚𝑠 = 𝐾 2 𝐼0,𝑚𝑎𝑥 ·𝐼 𝐶,𝑚𝑖𝑛 2 + 𝛼 1 +𝜋 2 · 𝐼2 𝐶,𝑚𝑖𝑛 · 𝐼 𝐶,𝑚𝑎𝑥 𝑚 𝑉 𝑑 ,𝑚𝑎𝑥 2 Da D1 ~ D4 VDa,peak 𝑚 𝑉 𝑑 ,𝑚𝑎𝑥 = 2 VD,peak =mVd,max IDa,peak=Io,max ,IDa,ave =ISa,ave,IDa,rms= ID,peak = ID,rms = 𝐼𝑆,𝑝𝑒𝑎𝑘 𝑉0 𝑚 ·𝑉 𝑑,𝑚𝑎𝑥 𝑚 + , 𝐼 𝐷,𝑎𝑣𝑒 = 1 2 𝐼0,𝑚𝑎𝑥 2 2 + 𝐼0,𝑚𝑎𝑥 2 𝑘 4𝜋 𝐾 2𝜋 · 𝜉2 + 2 · 𝐼0,𝑚𝑎𝑥 · 𝐼 𝐶,𝑚𝑎𝑥 + 𝛼2 · 𝐼 2 𝐶,𝑚𝑎𝑥 , − 3 𝐼0,𝑚𝑎𝑥 𝐼 𝐶,𝑚𝑎𝑥 72 2 + 𝛼2 + 𝜋 · 2𝐼0 ,𝑚𝑎𝑥 + 𝐼 2 ,𝑚𝑎𝑥 − 3 · 𝜉2 · (𝜉2 · +1) · 𝐶 𝐼0,𝑚𝑎𝑥 ·𝐼 𝐶,𝑚𝑎𝑥 2
  • 5. Study of Soft-Switched Isolated DC-DC Converters for Auxiliary… IV. MATLAB MODELING AND SIMULATION RESULTS Fig2. Matlab/Simulink Model of proposed Comparative Study of Soft-Switched Isolated DC-DCConverters for Auxiliary Railway Supply Fig 3. Output Voltage Fig 4. Output Current Fig 5 Output speed 73
  • 6. Study of Soft-Switched Isolated DC-DC Converters for Auxiliary… Fig 6 waveforms of voltage and current across transformer Fig 7 output of pulse generator V. CONCLUSION This paper has investigated topology of soft-switched isolated dc-dc converters for auxiliary railway supply. First, the operating principles and the design considerations have been presented in detail. Then, computer simulations have been conducted in accordance with the requirements of the specific railway application in order to verify the theoretical analysis. The steady-state output voltage characteristics at 3-kV input have been discussed for the topology, As an important requirement, the ability to supply 600-V output at light loads has also been studied from these characteristics ,here dc machine is used in place of resistive load then the output voltage is above 600v, Finally, a analysis of the topology has been carried out, the main outcomes are as follows: 1) the overall weight and size reduction of the passive components is rather in favour 2) even though less material is expected for as regards the transformer; 3) at rated conditions, the total power loss of the power semiconductor devices is significantly less for topology #1 (no hard-switching); 4) if the values of the resonant elements are changed within a prescribed tolerance, the two converters are still able to achieve ZCS; REFERENCES [1]. [2]. [3]. [4]. [5]. [6]. [7]. [8]. A. Steimel, “Electric railway traction in Europe,” IEEE Ind. Appl. Mag., vol. 2, no. 6, pp. 6–17, 1996. J. Weber, A. Berger, and A. Falk, “Galvanic separated high frequency power converter for auxiliary railway supply,” presented at the 10th Eur. Power Electron. Conf., Toulouse, France, Sep. 2003. D. Vinnikov, J. Laugis, and T. Jalakas, “Development of auxiliary power supplies for the 3.0 kV DC rolling stock,” in Proc. IEEE Int.Symp. Ind. Electron. (ISIE), Vigo, Spain, Jun. 2007, pp. 359–364. D. Vinnikov and J. Laugis, “High voltage auxiliary power supply with the simplified power circuit topology for the DC trains,” in Proc. 9th Int. Conf. Elect. Power Quality Utilisation (EPQU), Barcelona, Spain, 2007, pp. 1–6. T. Kjellqvist, S. Norrga, and S. Ostlund, “Design considerations for a medium frequency transformer in a line side power conversion system,” in Proc. IEEE 35th Annu. Power Elect. Spec. Conf., Aachen, Germany, 2004, pp. 704–71. T. Kjellqvist, S. Norrga, and S. Ostlund, “Switching frequency limit for soft-switching MF transformer system for AC-fed traction,” in Proc. IEEE 36th Annu. Power Elect. Spec. Conf., Recife, Brazil, 2005, pp. 1678–1684. A. Rufer, N. Schibli, C. Chabert, and C. Zimmermann, “Configurable front-end converters for multicurrent locomotives operated on 16 2/3 Hz AC and 3 kV DC systems,” IEEE Trans. Power Electron., vol. 18, no. 5, pp. 1186–1193, Sep. 2003. B. Engel, M. Victor, G. Bachman, and A. Falk, “15 kV/16.7 Hz energy supply system with medium frequency transformer and 6.5 kV IGBTs in resonant operation,” presented at the 10th Euro. Power Electron. Conf., Toulouse, France, 2003. 74
  • 7. Study of Soft-Switched Isolated DC-DC Converters for Auxiliary… [9]. [10]. [11]. [12]. [13]. [14]. [15]. [16]. S. Dieckerhoff and U. Schaefer, “Transformerless drive system for main line rail vehicle propulsion,” presented at the 9th Euro. Power Electron. Conf., Gratz, Austria, 2001. S. Dieckerhoff, S. Bernet, and D. Krug, “Power loss-oriented evaluation of high voltage IGBTs and multilevel onverters in transformerless traction applications,” IEEE Trans. Power Electron., vol. 20, no. 6, pp. 1328–1329, Nov. 2005. M. T. Aydemir, A. Bendre, and G. Venkataramanan, “A critical evaluation of high power hard and soft switched isolated DC-DC converters,” in Proc. 37th IAS Annu. Meet. Ind. Appl. Conf., 2002, pp. 1338– 1345. F. Z. Peng, H. Li, G.-J. Su, and J. S. Lawler, “A new ZVS bidirectional DC-DC converter for fuel cell and battery application,” IEEE Trans. Power Electron., vol. 19, no. 1, pp. 54–65, Jan. 2004. H. Li, F. Z. Peng, and J. S. Lawler, “A natural ZVS medium-power bidirectional DC-DC converter with minimum number of devices,” IEEE Trans. Ind. Appl., vol. 39, no. 2, pp. 525–535, Mar./Apr. 2003. L. Zhu, “A novel soft-commutating isolated boost full-bridge ZVS-PWM DC-DC converter for bidirectional high power applications,” IEEE Trans. Power Electron., vol. 21, no. 2, pp. 422–429, Mar. 2006. Q. Chongming and K. M. Smedley, “An isolated full bridge boost converter with active soft switching,” in Proc. IEEE 32nd Annu. Power Elect. Spec. Conf., Vancouver, BC, Canada, 2001, pp. 896–903. J. E. Baggio, H. L. Hey, and J. R. Pinheiro, “An improved full-loadrange isolated ZVS-PWM DC-DC converter,” in Proc. 6th Annu. IEEE Appl. Power Electron. Conf. Expos., Anaheim, CA, 2001, pp. 708–714. 75