This document proposes a hybrid Lightning Search Algorithm-Artificial Neural Network (LSA-ANN) based home energy management scheduling controller for residential demand response. It models common household appliances like air conditioners, water heaters, refrigerators and washing machines. The controller uses LSA to optimize ANN parameters like learning rate and number of hidden nodes to improve load scheduling accuracy. Results show the hybrid LSA-ANN approach reduces peak energy consumption by up to 9.7% compared to a hybrid PSO-ANN approach.
Energy Audit and Analysis of an Institutional Building under Subtropical Clim...IJECEIAES
Evaluation and estimation of energy consumption are essential in order to classify the amount of energy used and the way it is utilized in building. Hence, the possibility of any energy savings potential and energy savings opportunities can be identified. The intention of this article is to study and evaluate energy usage pattern of the Central Queensland University campus’ buildings, Queensland, Australia. This article presents the field survey results from the audit of an office building and performance-related measurements of the indoor environmental parameters, for instance, indoor air temperature, humidity and energy consumption concerned to the indoor heating and cooling load. Monthly observed energy usage information was employed to investigate influence of the climate conditions on energy usage.
Exergy analysis and igcc plant technology to improve the efficiency and to re...eSAT Publishing House
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
IRJET-Detailed Energy Audit in a Captive Cogeneration PlantIRJET Journal
D.Rajani Kant , B.Sudheer Prem Kumar, N.Ravi Kumar, R.Virendra,J.Suresh Babu " Detailed Energy Audit in a Captive Cogeneration Plant ", International Research Journal of Engineering and Technology (IRJET), Volume2,issue-01 April 2015.e-ISSN:2395-0056, p-ISSN:2395-0072. www.irjet.net
Abstract
The rate of exploitation of the energy resources has been expanding over time and resulted in reduction of fossil fuel reserves. Efficiency of all resources is crucial both in environmental and economic sense. Using energy inefficiently creates waste in all the world’s economies. It has environmental impacts with regional, local and global implications.The key object is to adopt energy management in every field in order to reduce the wastage of energy sources and cost effectiveness without affecting productivity and growth.
Resource aware wind farm and D-STATCOM optimal sizing and placement in a dist...IJECEIAES
Doubly fed induction generators (DFIG) based wind farms are capable of providing reactive power compensation. Compensation capability enhancement using reactors such as distributed static synchronous compensator (D-STATCOM) while connecting distribution generation (DG) systems to grid is imperative. This paper presents an optimal placement and sizing of offshore wind farms in a coastal distribution system that is emulated on an IEEE 33 bus system. A multi-objective formulation for optimal placement and sizing of the offshore wind farms with both the location and size constraints is developed. Teaching learning algorithm is used to optimize the multi-objective function constraining on the capacity and location of the offshore wind farms. The proposed formulation is a multi-objective problem for placement of the wind generator in the power system with dynamic wind supply to the power system. The random wind speed is generated as the input and the wind farm output generated to perform the optimal sizing and placement in the distributed system. MATLAB based simulation developed is found to be efficient and robust.
Energy Audit and Analysis of an Institutional Building under Subtropical Clim...IJECEIAES
Evaluation and estimation of energy consumption are essential in order to classify the amount of energy used and the way it is utilized in building. Hence, the possibility of any energy savings potential and energy savings opportunities can be identified. The intention of this article is to study and evaluate energy usage pattern of the Central Queensland University campus’ buildings, Queensland, Australia. This article presents the field survey results from the audit of an office building and performance-related measurements of the indoor environmental parameters, for instance, indoor air temperature, humidity and energy consumption concerned to the indoor heating and cooling load. Monthly observed energy usage information was employed to investigate influence of the climate conditions on energy usage.
Exergy analysis and igcc plant technology to improve the efficiency and to re...eSAT Publishing House
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
IRJET-Detailed Energy Audit in a Captive Cogeneration PlantIRJET Journal
D.Rajani Kant , B.Sudheer Prem Kumar, N.Ravi Kumar, R.Virendra,J.Suresh Babu " Detailed Energy Audit in a Captive Cogeneration Plant ", International Research Journal of Engineering and Technology (IRJET), Volume2,issue-01 April 2015.e-ISSN:2395-0056, p-ISSN:2395-0072. www.irjet.net
Abstract
The rate of exploitation of the energy resources has been expanding over time and resulted in reduction of fossil fuel reserves. Efficiency of all resources is crucial both in environmental and economic sense. Using energy inefficiently creates waste in all the world’s economies. It has environmental impacts with regional, local and global implications.The key object is to adopt energy management in every field in order to reduce the wastage of energy sources and cost effectiveness without affecting productivity and growth.
Resource aware wind farm and D-STATCOM optimal sizing and placement in a dist...IJECEIAES
Doubly fed induction generators (DFIG) based wind farms are capable of providing reactive power compensation. Compensation capability enhancement using reactors such as distributed static synchronous compensator (D-STATCOM) while connecting distribution generation (DG) systems to grid is imperative. This paper presents an optimal placement and sizing of offshore wind farms in a coastal distribution system that is emulated on an IEEE 33 bus system. A multi-objective formulation for optimal placement and sizing of the offshore wind farms with both the location and size constraints is developed. Teaching learning algorithm is used to optimize the multi-objective function constraining on the capacity and location of the offshore wind farms. The proposed formulation is a multi-objective problem for placement of the wind generator in the power system with dynamic wind supply to the power system. The random wind speed is generated as the input and the wind farm output generated to perform the optimal sizing and placement in the distributed system. MATLAB based simulation developed is found to be efficient and robust.
A New Solution to Improve Power Quality of Renewable Energy Sources Smart Gri...iosrjce
This particular article reveals a prototyped interface current control protocol which is ideal for
multilevel converters and it’s utilization with a three-phase cascaded H-bridge inverter. This kind of
administration approach utilizes a discrete-time type of the device to estimate the longer term benefit from the
current for many voltage vectors, as well as decides on the vector which in turn decreases an expense purpose.
A result of the multitude of voltage vectors obtainable in a multilevel inverter, numerous computations are
expected, producing challenging execution with this strategy in a typical control program. A new improved
strategic approach with the demonstration using physical framework as well as Matlab system significantly
decreases the number of computations without influencing the actual system’s effectiveness is suggested.
Experimental outcomes intended for five-level inverters confirm the suggested strategy. Additionally, author
considered the socio-environmental effects occurring due to carbon foot printing as per KYOTO protocol and
demonstrates the implementation of prototype carbon foot printing control sub-protocol for minimization of
carbon foot printing occurring due to microbial fuel cell micro-grid setup. Hence this will help to manage
attitudinal goals to improve electricity resource quality and efficiency.
The Friends of NELHA presented a 3 part workshop called Energy Efficiency and Auditing Workshop in Hawaii. This slideshow presentation by Dr. Roderick Hinman is the first section which discusses what electricity is, how it is measured, and how you can measure the electrical loads of each appliance in your home to make decisions that can save on your home electric bill.
The study is aimed to determine the measurement of sensor tool made in Model Real Time Hybrid LFG-PV-Genset by finding the correction factor produced at TPA Bontang City, East Borneo. The research was conducted by using ampere clammeter, variable voltage regulator, thermometer, odalog7000 series. The calculation results show that the calibration test of Model Real Time Hybrid LFG-PV-Genset from MQ4 sensor data that has been designed capable of having errors of 1,91% and the LM35 temperature sensor is capable of monitoring tempertures of 30°C to 120°C and has an error value of 0,519°C. ZMPT 101B voltage sensor has a linear output change to input changes and has an average error of 1.499V. While the current sensor SCT 013 has an aerage error value of 0,0022A CO2.
Reliability Constrained Unit Commitment Considering the Effect of DG and DR P...IJECEIAES
Due to increase in energy prices at peak periods and increase in fuel cost, involving Distributed Generation (DG) and consumption management by Demand Response (DR) will be unavoidable options for optimal system operations. Also, with high penetration of DGs and DR programs into power system operation, the reliability criterion is taken into account as one of the most important concerns of system operators in management of power system. In this paper, a Reliability Constrained Unit Commitment (RCUC) at presence of time-based DR program and DGs integrated with conventional units is proposed and executed to reach a reliable and economic operation. Designated cost function has been minimized considering reliability constraint in prevailing UC formulation. The UC scheduling is accomplished in short-term so that the reliability is maintained in acceptable level. Because of complex nature of RCUC problem and full AC load flow constraints, the hybrid algorithm included Simulated Annealing (SA) and Binary Particle Swarm Optimization (BPSO) has been proposed to optimize the problem. Numerical results demonstrate the effectiveness of the proposed method and considerable efficacy of the time-based DR program in reducing operational costs by implementing it on IEEE-RTS79.
Stochastic control for optimal power flow in islanded microgridIJECEIAES
The problem of optimal power flow (OPF) in an islanded mircrogrid (MG) for hybrid power system is described. Clearly, it deals with a formulation of an analytical control model for OPF. The MG consists of wind turbine generator, photovoltaic generator, and diesel engine generator (DEG), and is in stochastic environment such as load change, wind power fluctuation, and sun irradiation power disturbance. In fact, the DEG fails and is repaired at random times so that the MG can significantly influence the power flow, and the power flow control faces the main difficulty that how to maintain the balance of power flow? The solution is that a DEG needs to be scheduled. The objective of the control problem is to find the DEG output power by minimizing the total cost of energy. Adopting the Rishel’s famework and using the Bellman principle, the optimality conditions obtained satisfy the Hamilton-Jacobi-Bellman equation. Finally, numerical examples and sensitivity analyses are included to illustrate the importance and effectiveness of the proposed model.
Compromising between-eld-&-eed-using-gatool-matlabSubhankar Sau
Creating a compromising points between economic load dispatch & emission created from the plant to minimising those effects.
these are created by using MATLAB and GATOOL .
taking Weighted Sum Method,also Pareto optimal curve.
created by: SUBHANKAR SAU
Cascaded Thermodynamic and Environmental Analyses of Energy Generation Modali...Ozyegin University
This study presents cascaded thermodynamic and environmental analyses of a high-performance academic building. Five different energy efficiency measures and operation scenarios are evaluated based on the actual measurements starting from the initial design concept. The study is to emphasize that by performing dynamical energy, exergy, exergoeconomic, and environmental analyses with increasing complexity, a better picture of building performance indicators can be obtained for both the building owners and users, helping them to decide on different investment strategies. As the first improvement, the original design is modified by the addition of a ground-air heat exchanger for pre-conditioning the incoming air to heat the ground floors. The installation of roof-top PV panels to use solar energy is considered as the third case, and the use of a trigeneration system as an energy source instead of traditional boiler systems is considered as the fourth case. The last case is the integration of all these three alternative energy modalities for the building. It is determined that the use of a trigeneration system provides a better outcome than the other scenarios for decreased energy demand, for cost reduction, and for the improved exergy efficiency and sustainability index values relative to the original baseline design scenario. Yet, an integrated approach combining all these energy generation modalities provide the best return of investment.
Analysis of Process Parameters to Improve Power Plant EfficiencyIOSRJMCE
This research paper analyses the operational parameters of a thermal power plant to improve effectively & efficient running of the machine while ensuring a degree of compliance with statutory regulations. This study aims to identify the operational gaps associated with running operational parameter in power plant process. It is focused to detect a different thermodynamic variable involved, being multivariate and automatic. For variation of each one of this operational parameters, performance calculations are find out to configure a database of energy variation. The variable data sets now can be used as assessment criteria based on detecting deviations from a reference system that has been updated during plant-performance tests. Although the most important outcome is the highly precise and valuable information that will be obtained on the live operating mode, leading to a head improvements in the cycle efficiency and achieved in the overall control system of the thermal plant. The main aim is to detect any abnormality, reacting as quickly as possible to return the plant to a normal operation mode at best efficient manner.
International Journal of Engineering Research and Applications (IJERA) is an open access online peer reviewed international journal that publishes research and review articles in the fields of Computer Science, Neural Networks, Electrical Engineering, Software Engineering, Information Technology, Mechanical Engineering, Chemical Engineering, Plastic Engineering, Food Technology, Textile Engineering, Nano Technology & science, Power Electronics, Electronics & Communication Engineering, Computational mathematics, Image processing, Civil Engineering, Structural Engineering, Environmental Engineering, VLSI Testing & Low Power VLSI Design etc.
Design methodology of smart photovoltaic plant IJECEIAES
In this article, we present a new methodology to design an intelligent photovoltaic power plant connected to an electrical grid with storage to supply the laying hen rearing centers. This study requires a very competent design methodology in order to optimize the production and consumption of electrical energy. Our contribution consists in proposing a robust dimensioning synthesis elaborated according to a data flow chart. To achieve this objective, the photovoltaic system was first designed using a deterministic method, then the software "Homer" was used to check the feasibility of the design. Then, controllers (fuzzy logic) were used to optimize the energy produced and consumed. The power produced by the photovoltaic generator (GPV) is optimized by two fuzzy controllers: one to extract the maximum energy and another to control the batteries. The energy consumed by the load is optimized by a fuzzy controller that regulates the internal climate of the livestock buildings. The proposed control strategies are developed and implemented using MATLAB/Simulink.
Optimal scheduling and demand response implementation for home energy managementIJECEIAES
The optimal scheduling of the loads based on dynamic tariffs and implementation of a direct load control (DLC) based demand response program for the domestic consumer is proposed in this work. The load scheduling is carried out using binary particle swarm optimization and a newly prefaced nature-inspired discrete elephant herd optimization technique, and their effectiveness in minimization of cost and the peak-toaverage ratio is analyzed. The discrete elephant herd optimization algorithm has acceptable characteristics compared to the conventional algorithms and has determined better exploring properties for multi-objective problems. A prototype hardware model for a home energy management system is developed to demonstrate and analyze the optimal load scheduling and DLCbased demand response program. The controller effectively schedules and implements DLC on consumer devices. The load scheduling optimization helps to improve PAR by a value of 2.504 and results in energy cost savings of ₹ 12.05 on the scheduled day. Implementation of DLC by 15% results in monthly savings of ₹ 204.18. The novelty of the work is the implementation of discrete elephant herd optimization for load scheduling and the development of the prototype hardware model to show effects of both optimal load scheduling and the DLC-based demand response program implementation.
Renewable energy based dynamic tariff system for domestic load managementnooriasukmaningtyas
To deal with the present power-scenario, this paper proposes a model of an advanced energy management system, which tries to achieve peak clipping, peak to average ratio reduction and cost reduction based on effective utilization of distributed generations. This helps to manage conventional loads based on flexible tariff system. The main contribution of this work is the development of three-part dynamic tariff system on the basis of time of utilizing power, available renewable energy sources (RES) and consumers’ load profile. This incorporates consumers’ choice to suitably select for either consuming power from conventional energy sources and/or renewable energy sources during peak or off-peak hours. To validate the efficiency of the proposed model we have comparatively evaluated the model performance with existing optimization techniques using genetic algorithm and particle swarm optimization. A new optimization technique, hybrid greedy particle swarm optimization has been proposed which is based on the two aforementioned techniques. It is found that the proposed model is superior with the improved tariff scheme when subjected to load management and consumers’ financial benefit. This work leads to maintain a healthy relationship between the utility sectors and the consumers, thereby making the existing grid more reliable, robust, flexible yet cost effective.
A New Solution to Improve Power Quality of Renewable Energy Sources Smart Gri...iosrjce
This particular article reveals a prototyped interface current control protocol which is ideal for
multilevel converters and it’s utilization with a three-phase cascaded H-bridge inverter. This kind of
administration approach utilizes a discrete-time type of the device to estimate the longer term benefit from the
current for many voltage vectors, as well as decides on the vector which in turn decreases an expense purpose.
A result of the multitude of voltage vectors obtainable in a multilevel inverter, numerous computations are
expected, producing challenging execution with this strategy in a typical control program. A new improved
strategic approach with the demonstration using physical framework as well as Matlab system significantly
decreases the number of computations without influencing the actual system’s effectiveness is suggested.
Experimental outcomes intended for five-level inverters confirm the suggested strategy. Additionally, author
considered the socio-environmental effects occurring due to carbon foot printing as per KYOTO protocol and
demonstrates the implementation of prototype carbon foot printing control sub-protocol for minimization of
carbon foot printing occurring due to microbial fuel cell micro-grid setup. Hence this will help to manage
attitudinal goals to improve electricity resource quality and efficiency.
The Friends of NELHA presented a 3 part workshop called Energy Efficiency and Auditing Workshop in Hawaii. This slideshow presentation by Dr. Roderick Hinman is the first section which discusses what electricity is, how it is measured, and how you can measure the electrical loads of each appliance in your home to make decisions that can save on your home electric bill.
The study is aimed to determine the measurement of sensor tool made in Model Real Time Hybrid LFG-PV-Genset by finding the correction factor produced at TPA Bontang City, East Borneo. The research was conducted by using ampere clammeter, variable voltage regulator, thermometer, odalog7000 series. The calculation results show that the calibration test of Model Real Time Hybrid LFG-PV-Genset from MQ4 sensor data that has been designed capable of having errors of 1,91% and the LM35 temperature sensor is capable of monitoring tempertures of 30°C to 120°C and has an error value of 0,519°C. ZMPT 101B voltage sensor has a linear output change to input changes and has an average error of 1.499V. While the current sensor SCT 013 has an aerage error value of 0,0022A CO2.
Reliability Constrained Unit Commitment Considering the Effect of DG and DR P...IJECEIAES
Due to increase in energy prices at peak periods and increase in fuel cost, involving Distributed Generation (DG) and consumption management by Demand Response (DR) will be unavoidable options for optimal system operations. Also, with high penetration of DGs and DR programs into power system operation, the reliability criterion is taken into account as one of the most important concerns of system operators in management of power system. In this paper, a Reliability Constrained Unit Commitment (RCUC) at presence of time-based DR program and DGs integrated with conventional units is proposed and executed to reach a reliable and economic operation. Designated cost function has been minimized considering reliability constraint in prevailing UC formulation. The UC scheduling is accomplished in short-term so that the reliability is maintained in acceptable level. Because of complex nature of RCUC problem and full AC load flow constraints, the hybrid algorithm included Simulated Annealing (SA) and Binary Particle Swarm Optimization (BPSO) has been proposed to optimize the problem. Numerical results demonstrate the effectiveness of the proposed method and considerable efficacy of the time-based DR program in reducing operational costs by implementing it on IEEE-RTS79.
Stochastic control for optimal power flow in islanded microgridIJECEIAES
The problem of optimal power flow (OPF) in an islanded mircrogrid (MG) for hybrid power system is described. Clearly, it deals with a formulation of an analytical control model for OPF. The MG consists of wind turbine generator, photovoltaic generator, and diesel engine generator (DEG), and is in stochastic environment such as load change, wind power fluctuation, and sun irradiation power disturbance. In fact, the DEG fails and is repaired at random times so that the MG can significantly influence the power flow, and the power flow control faces the main difficulty that how to maintain the balance of power flow? The solution is that a DEG needs to be scheduled. The objective of the control problem is to find the DEG output power by minimizing the total cost of energy. Adopting the Rishel’s famework and using the Bellman principle, the optimality conditions obtained satisfy the Hamilton-Jacobi-Bellman equation. Finally, numerical examples and sensitivity analyses are included to illustrate the importance and effectiveness of the proposed model.
Compromising between-eld-&-eed-using-gatool-matlabSubhankar Sau
Creating a compromising points between economic load dispatch & emission created from the plant to minimising those effects.
these are created by using MATLAB and GATOOL .
taking Weighted Sum Method,also Pareto optimal curve.
created by: SUBHANKAR SAU
Cascaded Thermodynamic and Environmental Analyses of Energy Generation Modali...Ozyegin University
This study presents cascaded thermodynamic and environmental analyses of a high-performance academic building. Five different energy efficiency measures and operation scenarios are evaluated based on the actual measurements starting from the initial design concept. The study is to emphasize that by performing dynamical energy, exergy, exergoeconomic, and environmental analyses with increasing complexity, a better picture of building performance indicators can be obtained for both the building owners and users, helping them to decide on different investment strategies. As the first improvement, the original design is modified by the addition of a ground-air heat exchanger for pre-conditioning the incoming air to heat the ground floors. The installation of roof-top PV panels to use solar energy is considered as the third case, and the use of a trigeneration system as an energy source instead of traditional boiler systems is considered as the fourth case. The last case is the integration of all these three alternative energy modalities for the building. It is determined that the use of a trigeneration system provides a better outcome than the other scenarios for decreased energy demand, for cost reduction, and for the improved exergy efficiency and sustainability index values relative to the original baseline design scenario. Yet, an integrated approach combining all these energy generation modalities provide the best return of investment.
Analysis of Process Parameters to Improve Power Plant EfficiencyIOSRJMCE
This research paper analyses the operational parameters of a thermal power plant to improve effectively & efficient running of the machine while ensuring a degree of compliance with statutory regulations. This study aims to identify the operational gaps associated with running operational parameter in power plant process. It is focused to detect a different thermodynamic variable involved, being multivariate and automatic. For variation of each one of this operational parameters, performance calculations are find out to configure a database of energy variation. The variable data sets now can be used as assessment criteria based on detecting deviations from a reference system that has been updated during plant-performance tests. Although the most important outcome is the highly precise and valuable information that will be obtained on the live operating mode, leading to a head improvements in the cycle efficiency and achieved in the overall control system of the thermal plant. The main aim is to detect any abnormality, reacting as quickly as possible to return the plant to a normal operation mode at best efficient manner.
International Journal of Engineering Research and Applications (IJERA) is an open access online peer reviewed international journal that publishes research and review articles in the fields of Computer Science, Neural Networks, Electrical Engineering, Software Engineering, Information Technology, Mechanical Engineering, Chemical Engineering, Plastic Engineering, Food Technology, Textile Engineering, Nano Technology & science, Power Electronics, Electronics & Communication Engineering, Computational mathematics, Image processing, Civil Engineering, Structural Engineering, Environmental Engineering, VLSI Testing & Low Power VLSI Design etc.
Design methodology of smart photovoltaic plant IJECEIAES
In this article, we present a new methodology to design an intelligent photovoltaic power plant connected to an electrical grid with storage to supply the laying hen rearing centers. This study requires a very competent design methodology in order to optimize the production and consumption of electrical energy. Our contribution consists in proposing a robust dimensioning synthesis elaborated according to a data flow chart. To achieve this objective, the photovoltaic system was first designed using a deterministic method, then the software "Homer" was used to check the feasibility of the design. Then, controllers (fuzzy logic) were used to optimize the energy produced and consumed. The power produced by the photovoltaic generator (GPV) is optimized by two fuzzy controllers: one to extract the maximum energy and another to control the batteries. The energy consumed by the load is optimized by a fuzzy controller that regulates the internal climate of the livestock buildings. The proposed control strategies are developed and implemented using MATLAB/Simulink.
Optimal scheduling and demand response implementation for home energy managementIJECEIAES
The optimal scheduling of the loads based on dynamic tariffs and implementation of a direct load control (DLC) based demand response program for the domestic consumer is proposed in this work. The load scheduling is carried out using binary particle swarm optimization and a newly prefaced nature-inspired discrete elephant herd optimization technique, and their effectiveness in minimization of cost and the peak-toaverage ratio is analyzed. The discrete elephant herd optimization algorithm has acceptable characteristics compared to the conventional algorithms and has determined better exploring properties for multi-objective problems. A prototype hardware model for a home energy management system is developed to demonstrate and analyze the optimal load scheduling and DLCbased demand response program. The controller effectively schedules and implements DLC on consumer devices. The load scheduling optimization helps to improve PAR by a value of 2.504 and results in energy cost savings of ₹ 12.05 on the scheduled day. Implementation of DLC by 15% results in monthly savings of ₹ 204.18. The novelty of the work is the implementation of discrete elephant herd optimization for load scheduling and the development of the prototype hardware model to show effects of both optimal load scheduling and the DLC-based demand response program implementation.
Renewable energy based dynamic tariff system for domestic load managementnooriasukmaningtyas
To deal with the present power-scenario, this paper proposes a model of an advanced energy management system, which tries to achieve peak clipping, peak to average ratio reduction and cost reduction based on effective utilization of distributed generations. This helps to manage conventional loads based on flexible tariff system. The main contribution of this work is the development of three-part dynamic tariff system on the basis of time of utilizing power, available renewable energy sources (RES) and consumers’ load profile. This incorporates consumers’ choice to suitably select for either consuming power from conventional energy sources and/or renewable energy sources during peak or off-peak hours. To validate the efficiency of the proposed model we have comparatively evaluated the model performance with existing optimization techniques using genetic algorithm and particle swarm optimization. A new optimization technique, hybrid greedy particle swarm optimization has been proposed which is based on the two aforementioned techniques. It is found that the proposed model is superior with the improved tariff scheme when subjected to load management and consumers’ financial benefit. This work leads to maintain a healthy relationship between the utility sectors and the consumers, thereby making the existing grid more reliable, robust, flexible yet cost effective.
An Energy Aware Resource Utilization Framework to Control Traffic in Cloud Ne...IJECEIAES
Energy consumption in cloud computing occur due to the unreasonable way in which tasks are scheduled. So energy aware task scheduling is a major concern in cloud computing as energy consumption results into significant waste of energy, reduce the profit margin and also high carbon emissions which is not environmentally sustainable. Hence, energy efficient task scheduling solutions are required to attain variable resource management, live migration, minimal virtual machine design, overall system efficiency, reduction in operating costs, increasing system reliability, and prompting environmental protection with minimal performance overhead. This paper provides a comprehensive overview of the energy efficient techniques and approaches and proposes the energy aware resource utilization framework to control traffic in cloud networks and overloads.
Advance Data Mining - Analysis and forecasting of power factor for optimum el...Shrikant Samarth
Task: Execute a research project using data mining techniques
Approach: The topic chosen was ‘Analysis and Forecasting of Power Factor for Optimum Electric Consumption in a Household.’ Research question – What can be the best short term range of forecast for power factor patterns so that optimum energy consumption can be achieved for a household?
To answer the question, CRISM- DM method was used. The ARIMA machine learning model was developed using R.
Findings: The best short term range of forecasts for the power factor was achieved for 6 months and 12 months duration using the ARIMA model. The MAPE value for the ARIMA model was around 1.83.
Tools: Rstudio
Performance Analysis of Autonomous Hybrid Distributed Generation Based on Typ...ijtsrd
It is undeniable fact that even though fossil fuels are likely more to fulfill the requirements of energy, the rare of natural resources and their harmful contents for the environment have directed people to search for new energy sources like renewable resources such as hydropower, biomass, wind, solar and other types of clean energy. In order to highlight the proposed methodology, PV Diesel generator DG with battery energy system BESS based on two typical control strategies, load following LF control strategy and cycle charging CC control strategy, have been analyzed by using HOMER Software to supply the Makyiyay village which is located at 22.02 north latitude and 96.56 east longitude in the Naungkhyo Township, Southern Shan State in Myanmar. The yearly average solar radiation of that area is 4.895kWh m2 day and it is very important to prepare a proper load data to meet the current situation of the target village which has 45 household numbers. By calculating the total load demand, the peak demand of that proposed village is 34kW. The fractions of energy production from PV array and diesel generator of the proposed PV Diesel BESS hybrid system using LF control strategy are 60 and 40 to meet the demand. Moreover, the proposed hybrid system based on LF control strategy provides the lowest TNPC, COE and carbon emission than the hybrid system based on CC control strategy according to the evaluation results. In contrast, the analysis of evaluation results shows that the PV Diesel ESS based on LF control choice is more economically possible than that system based on CC control. Phyu Phyu Win | Zin Mar "Performance Analysis of Autonomous Hybrid Distributed Generation Based on Typical Control Strategies for Rural Electrification in Myanmar" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd26695.pdfPaper URL: https://www.ijtsrd.com/engineering/electrical-engineering/26695/performance-analysis-of-autonomous-hybrid-distributed-generation-based-on-typical-control-strategies-for-rural-electrification-in-myanmar/phyu-phyu-win
Sampling-Based Model Predictive Control of PV-Integrated Energy Storage Syste...Power System Operation
This paper proposes a novel control solution designed to solve the local and grid-connected
distributed energy resources (DERs) management problem by developing a generalizable framework capable
of controlling DERs based on forecasted values and real-time energy prices. The proposed model uses
sampling-based model predictive control (SBMPC), together with the real-time price of energy and forecasts
of PV and load power, to allocate the dispatch of the available distributed energy resources (DERs) while
minimizing the overall cost. The strategy developed aims to nd the ideal combination of solar, grid, and
energy storage (ES) power with the objective of minimizing the total cost of energy of the entire system.
Both ofine and controller hardware-in-the-loop (CHIL) results are presented for a 7-day test case scenario
and compared with two manual base test cases and four baseline optimization algorithms (Genetic Algo-
rithm (GA), Particle Swarm Optimization (PSO), Quadratic Programming interior-point method (QP-IP),
and Sequential Quadratic Programming (SQP)) designed to solve the optimization problem considering the
current status of the system and also its future states. The proposed model uses a 24-hour prediction horizon
with a 15-minute control horizon. The results demonstrate substantial cost and execution time savings when
compared to the other baseline control algorithms.
Residential Community Load Management based on Optimal Design of Standalone H...Asoka Technologies
Microgrids being an important entity in the distribution system, and to get their full advantages
by incorporating maximum distributed generation, standalone hybrid renewable energy systems (HRESs), being environmentally-safe and economically-efficient, are considered as the promising solution to electrify remote areas where the grid power is not available. In this work, a techno-economic investigation with an optimal design of HRES is presented to fulfill the domestic electricity need for a residential area of the Sherani district in the Province of Baluchistan, Pakistan. Nine case studies based on PV/wind/diesel/battery are analyzed based on net present cost (NPC), cost of energy (COE), and emission to decide the feasible solution. HOMER tool is utilized to accomplish modeling and simulation for economic analysis and optimal sizing. Simulation results demonstrated that HRES with PV-wind-battery is the most viable option for the specified area, and the optimal sizing of components are also obtained with $ 28,620 NPC and 0.311 $/kWh COE which shows 81.65% reduction in cost and 100% preserving in toxic emission while fulfilling 100% energy demand with 67.3% of excess energy. Furthermore, MATLAB/Simulink modeling for the optimally designed system is built for technical analysis while its effectiveness is proved by keeping dc and ac buses voltage constant, safe operating range of battery state of charge (SOC) with active power balance between HRES components, as well as efficient ac voltage quality, regardless of generation disturbances and load fluctuations. The output signal has total harmonic distortion (THD) of 0.30% as compared to 5.44% with the conventional control scheme. The novelty lies in the sequential application of both HOMER and MATLAB simulations of the proposed HRES model and validation of the proposition for the studied area; by using and implementing model predictive control (MPC) of a reconfigurable inverter.
This paper presents a Stand-alone Hybrid Renewable Energy System (SHRES) as an alternative to fossil fuel based generators. The Photovoltaic (PV) panels and wind turbines (WT) are designed for the Malaysian low wind speed conditions with battery Energy Storage (BES) to provide electric power to the load. The appropriate sizing of each component was accomplished using Non-dominated Sorting Genetic Algorithm (NSGA-II) and Multi-Objective Particle Swarm Optimization (MOPSO) techniques. The optimized hybrid system was examined in MATLAB using two case studies to find the optimum number of PV panels, wind turbines system and BES that minimizes the Loss of Power Supply Probability (LPSP) and Cost of Energy (COE). The hybrid power system was connected to the AC bus to investigate the system performance in supplying a rural settlement. Real weather data at the location of interest was utilized in this paper. The results obtained from the two scenarios were used to compare the suitability of the NSGA-II and MOPSO methods. The NSGA-II method is shown to be more accurate whereas the MOPSO method is faster in executing the optimization. Hence, both these methods can be used for techno-economic optimization of SHRES.
Feasibility and optimal design of a hybrid power system for rural electrifica...IJECEIAES
A hybrid renewable energy system is at present accepted globally, as the best option for rural electrification particularly in areas where grid extension is infeasible. However, the need for hybrid design to be optimal in terms of operation and component selection serves as a challenge in obtaining reliable electricity at a minimum cost. In this work, the feasibility of installing a small hydropower into an existing water supply dam and the development of an optimal sizing optimization model for a small village-Itapaji, Nigeria were carried out. The developed hybrid power system (HPS) model consists of solar photovoltaic, small hydropower, battery and diesel generator. The optimal sizing of the system’s components for optimum configuration was carried out using Genetic Algorithm. The hybrid model’s results were compared with hybrid optimization model for electric renewable (HOMER) using correlation coefficient (r) and root mean square error (RMSE) to verify its validity. The results of the simulation obtained from the developed model showed better correlation coefficient (r) of 0.88 and root mean square error (RMSE) of 0.001 when compared to that of HOMER. This will serve as a guide for the power system engineers in the feasibility assessment and optimal design of HPS for rural electrification.
Feasibility and optimal design of a hybrid power system for rural electrifica...IJECEIAES
A hybrid renewable energy system is at present accepted globally, as the best option for rural electrification particularly in areas where grid extension is infeasible. However, the need for hybrid design to be optimal in terms of operation and component selection serves as a challenge in obtaining reliable electricity at a minimum cost. In this work, the feasibility of installing a small hydropower into an existing water supply dam and the development of an optimal sizing optimization model for a small village-Itapaji, Nigeria were carried out. The developed hybrid power system (HPS) model consists of solar photovoltaic, small hydropower, battery and diesel generator. The optimal sizing of the system’s components for optimum configuration was carried out using Genetic Algorithm. The hybrid model’s results were compared with hybrid optimization model for electric renewable (HOMER) using correlation coefficient (r) and root mean square error (RMSE) to verify its validity. The results of the simulation obtained from the developed model showed better correlation coefficient (r) of 0.88 and root mean square error (RMSE) of 0.001 when compared to that of HOMER. This will serve as a guide for the power system engineers in the feasibility assessment and optimal design of HPS for rural electrification.
Optimizing Size of Variable Renewable Energy Sources by Incorporating Energy ...Kashif Mehmood
The electricity sector contributes to most of the global warming emissions generated from
fossil fuel resources which are becoming rare and expensive due to geological extinction and climate
change. It urges the need for less carbon-intensive, inexhaustible Renewable Energy Sources (RES) that
are economically sound, easy to access and improve public health. The carbon-free salient feature is the
driving motive that propels widespread utilization of wind and solar RES in comparisons to rest of RES.
However, stochastic nature makes these sources, variable renewable energy sources (VRES) because it brings
uncertainty and variability that disrupt power system stability. This problem is mitigated by adding energy
storage (ES) or introducing the demand response (DR) in the system. In this paper, an electricity generation
network of China by the year 2017 is modeled using EnergyPLAN software to determine annual costs,
primary energy supply (PES) and CO2 emissions. The VRES size is optimized by adding ES and DR (daily,
weekly, or monthly) while maintaining critical excess electricity production (CEEP) to zero. The results
substantiate that ES and DR increase wind and solar share up to 1000 and 874 GW. In addition, it also
reduces annual costs and emissions up to 4.36 % and 45.17 %
optimization of the managed electrical energy within a hybrid renewable energ...INFOGAIN PUBLICATION
Hybrid energy applications based on renewable energy sources are becoming more and more desirable every day. They have increased the economic attractiveness of renewable electric energy generation. Because of the sudden fluctuations of the load requirements, the main attribute of such Hybrid Systems is to be able to generate energy at any time by optimally using each source. In this article, we have proposed a combination between a sizing study and a control one for the aim of solving the complex optimization problem of finding the optimal combination of size and storage to make the best use of the renewable power generations and to become more independent of rising electricity costs. Additionally, an improvement in the induced optimization algorithm is introduced in this paper so as to compute the optimal size and the operation control of the system with the aim of minimizing as much as possible the cost while responding to the load energy requirements taking into account the environmental factors.
Comparative Study Improving Residential Load Factor Using Power Shifting and ...TELKOMNIKA JOURNAL
One the problem of electric power stability is due to load fluctuations in distribution system
especialy during peak load conditions. One solution which is applied in Smart Grid scheme is through load
shifting or power shifting. In load shifting the load with high power consumption which operates at peak
load shifted its operations outside of the peak load or s some loads with high power consumption do not
operate at the same time, there is a load whose operating time is shifted to reduce peak power. Power
shifting is used when energy from renewable source not directly suplied to load but storage first and
supplied to reduce high power consumption to reduce peak power. Low load factor, ratio between average
power to peak power, may affect to power system operation. If load factor of residential load can keep in
low, it will be certainly help improve the stabi lity of the power system. In this study we will examine the
comparison of load shifting method with power shifting in improving load factor. Load shifting is done to
water pumps and washing machines, because washing machine is shiftable load. Power shiftin g is made
to the output power of the solar power plant, which is used to reduce peak power from the water pump.
Test results show that power shifting can increase load factor value up to 54,9% while load shifting give
load factor value equal to 43,9%.
A hybrid non-dominated sorting genetic algorithm for a multi-objective deman...IJECEIAES
One of the most significant challenges facing optimization models for the demand-side management (DSM) is obtaining feasible solutions in a shorter time. In this paper, the DSM is formulated in a smart building as a linear constrained multi-objective optimization model to schedule both electrical and thermal loads over one day. Two objectives are considered, energy cost and discomfort caused by allowing flexibility of loads within an acceptable comfort range. To solve this problem, an integrative matheuristic is proposed by combining a multi-objective evolutionary algorithm as a master level with an exact solver as a slave level. To cope with the non-triviality of feasible solutions representation and NP-hardness of our optimization model, in this approach discrete decision variables are encoded as partial chromosomes and the continuous decision variables are determined optimally by an exact solver. This matheuristic is relevant for dealing with the constraints of our optimization model. To validate the performance of our approach, a number of simulations are performed and compared with the goal programming under various scenarios of cold and hot weather conditions. It turns out that our approach outperforms the goal programming with respect to some comparison metrics including the hypervolume difference, epsilon indicator, number of the Pareto solutions found, and computational time metrics.
A novel hybrid modelling structure fabricated by using Takagi-Sugeno fuzzy to forecast HVAC systems energy demand in real-time for Basra city
Raad Z. Homod
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...Amil Baba Dawood bangali
Contact with Dawood Bhai Just call on +92322-6382012 and we'll help you. We'll solve all your problems within 12 to 24 hours and with 101% guarantee and with astrology systematic. If you want to take any personal or professional advice then also you can call us on +92322-6382012 , ONLINE LOVE PROBLEM & Other all types of Daily Life Problem's.Then CALL or WHATSAPP us on +92322-6382012 and Get all these problems solutions here by Amil Baba DAWOOD BANGALI
#vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore#blackmagicformarriage #aamilbaba #kalajadu #kalailam #taweez #wazifaexpert #jadumantar #vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore #blackmagicforlove #blackmagicformarriage #aamilbaba #kalajadu #kalailam #taweez #wazifaexpert #jadumantar #vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore #Amilbabainuk #amilbabainspain #amilbabaindubai #Amilbabainnorway #amilbabainkrachi #amilbabainlahore #amilbabaingujranwalan #amilbabainislamabad
Water scarcity is the lack of fresh water resources to meet the standard water demand. There are two type of water scarcity. One is physical. The other is economic water scarcity.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Hierarchical Digital Twin of a Naval Power SystemKerry Sado
A hierarchical digital twin of a Naval DC power system has been developed and experimentally verified. Similar to other state-of-the-art digital twins, this technology creates a digital replica of the physical system executed in real-time or faster, which can modify hardware controls. However, its advantage stems from distributing computational efforts by utilizing a hierarchical structure composed of lower-level digital twin blocks and a higher-level system digital twin. Each digital twin block is associated with a physical subsystem of the hardware and communicates with a singular system digital twin, which creates a system-level response. By extracting information from each level of the hierarchy, power system controls of the hardware were reconfigured autonomously. This hierarchical digital twin development offers several advantages over other digital twins, particularly in the field of naval power systems. The hierarchical structure allows for greater computational efficiency and scalability while the ability to autonomously reconfigure hardware controls offers increased flexibility and responsiveness. The hierarchical decomposition and models utilized were well aligned with the physical twin, as indicated by the maximum deviations between the developed digital twin hierarchy and the hardware.
Hybrid lsaann based home energy management scheduling controller for residential demand response strategy
1. energies
Article
Hybrid LSA-ANN Based Home Energy Management
Scheduling Controller for Residential Demand
Response Strategy
Maytham S. Ahmed 1,2,*, Azah Mohamed 1, Raad Z. Homod 3 and Hussain Shareef 4
1 Department of Electrical, Electronic and System Engineering, Faculty of Engineering and
Built Environments, Universiti Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia;
azah_mohamed@ukm.edu.my
2 General Directorate of Electrical Energy Production-Basrah, Ministry of Electricity, Basrah 61001, Iraq
3 Department of Petroleum and Gas Engineering, Basrah University for Gas and Oil, Qarmat Ali Campus,
Basrah 61004, Iraq; raadahmood@yahoo.com
4 Department of Electrical Engineering, United Arab Emirates University, Al-Ain 15551, UAE;
hussain_ln@yahoo.com
* Correspondence: eng_maitham@yahoo.com; Tel.: +60-182-279-921
Academic Editor: Giovanni Pau
Received: 15 June 2016; Accepted: 30 August 2016; Published: 6 September 2016
Abstract: Demand response (DR) program can shift peak time load to off-peak time, thereby reducing
greenhouse gas emissions and allowing energy conservation. In this study, the home energy
management scheduling controller of the residential DR strategy is proposed using the hybrid
lightning search algorithm (LSA)-based artificial neural network (ANN) to predict the optimal
ON/OFF status for home appliances. Consequently, the scheduled operation of several appliances is
improved in terms of cost savings. In the proposed approach, a set of the most common residential
appliances are modeled, and their activation is controlled by the hybrid LSA-ANN based home
energy management scheduling controller. Four appliances, namely, air conditioner, water heater,
refrigerator, and washing machine (WM), are developed by Matlab/Simulink according to customer
preferences and priority of appliances. The ANN controller has to be tuned properly using suitable
learning rate value and number of nodes in the hidden layers to schedule the appliances optimally.
Given that finding proper ANN tuning parameters is difficult, the LSA optimization is hybridized
with ANN to improve the ANN performances by selecting the optimum values of neurons in each
hidden layer and learning rate. Therefore, the ON/OFF estimation accuracy by ANN can be improved.
Results of the hybrid LSA-ANN are compared with those of hybrid particle swarm optimization
(PSO) based ANN to validate the developed algorithm. Results show that the hybrid LSA-ANN
outperforms the hybrid PSO based ANN. The proposed scheduling algorithm can significantly
reduce the peak-hour energy consumption during the DR event by up to 9.7138% considering four
appliances per 7-h period.
Keywords: lightning search algorithm (LSA); home energy management system (HEMS);
artificial neural network (ANN); load scheduling; residential demand response (DR)
1. Introduction
In recent years, the peak demand has been increasing in the domestic sector and caused unwanted
effects to the reliability and stability of power systems. The total energy demand is estimated to
increase by 75% at the end of 2020 compared to 2000 [1]. Peak time loads occur in the grid when
most end users are using electricity at the same time in a day [2]. In this case, power suppliers are
forced to increase generation to meet the high demand, thereby increasing carbon dioxide emission [3],
Energies 2016, 9, 716; doi:10.3390/en9090716 www.mdpi.com/journal/energies
2. Energies 2016, 9, 716 2 of 20
which can promote climate change [4]. Energy consumption in a residential building depends on many
factors, such as the number of occupants living in the house, and usage pattern of household [5] as
well as period of use, and appliance power [6]. The technology for home energy management system
(HEMS) is efficient with data communication networks, which connect home appliances for remote
management based on the internet and a combination of the home network to reduce the peak demand
that leads to reduced risk of outages at the power distribution and transmission network [7]. A smart
home enabled with residential demand response (DR) technologies features a function of HEMS that
manages controllable appliances associated with smart socket and meters [8]. DR plays an important
role in encouraging residential customers to participate in the distribution system. These programs
are designed with an electricity tariff to persuade residential end users to voluntarily decrease their
daily electrical consumption pattern or maximize their satisfaction by allocating available resources
and effectively managing the electricity loads [9]. Participating customers in DR programs can save
on electricity bills when they reduce their electricity usages during peak periods and shifting peak
time load to off-peak time. HEMS can assist in the reduction of overall energy consumption through
optimal residential load scheduling of appliances and to achieve various goals and functions in homes,
such as automatic control, shift, or curtailment of the demand consumption [10].
Many optimization techniques can be used to solve many problems for different applications.
Particle swarm optimization (PSO) has been used to minimize the annual total building energy
consumption and to improve the building energy performance [11]. Similarly, fuzzy logic control
was improved using the quantum lightning search algorithm and backtracking search algorithm to
control an induction motor drive [12,13], and a quantum gravitational search optimization algorithm
was used to solve the optimal power quality monitor placement problem in power systems [14].
A variety of methods and optimization techniques have been used recently to help end users create
optimal appliance scheduling of energy usage based on different feed-in tariffs, pricing schemes,
and comfort settings. Kang et al. [15] proposed long-term scheduling and real-time pricing to operate
a framework of building an energy management system that included distributed energy storage
systems and energy resources to achieve optimal decisions. Optimal energy consumption scheduling
based on linear programming computations was applied to minimize the electricity bill and waiting
time for each home appliance that operates with real-time pricing tariff [16]. While Haider et al. [17]
presented dynamic residential load scheduling and used to achieve optimal scheduling of household
appliances to allow end users to decrease energy bills and reduce the peak load. In some related
works, neural networks have been used to save electric energy in residential lighting by implementing
specific schedules [18]. Pedrasa et al. [19] used stochastic programming approach formulated for
robust scheduling of four controllable residential distributed energy resources. The robust schedules
were formulated using an improved version of PSO technique to maximize the net benefit of end
users as the objective function to reduce electricity bill The method for scheduling home appliances
was developed by using a mixed integer nonlinear optimization model built under time-of-use
electricity tariff to minimize electricity costs, so that consumers were able to participate in a DR
program by making a decision [20]. The PSO algorithm was applied to optimize desirable points
during the appliance operation time [21]. Several studies combined the schedules of home appliances
with renewable sources. Artificial neural network (ANN) with genetic algorithm has been applied
for weekly appliance scheduling with optimized energy consumption in the residential sector to
reduce energy demand during peak periods and to maximize the usage of renewable sources [22].
Gharghan et al. [23] hybridized the PSO with ANN to improve the ANN operation by selecting
the optimum number of neurons in each hidden layer and learning rate, in which the selection of
these parameters was formerly made using the trial and error approach and did not always provide
optimum solutions. Neural network is an approach designed to handle any complex nonlinear
functions with accuracy through training and learning system input and output. A major challenge
faced in scheduling household appliances is the minimization of the energy consumption in a given
period without affecting the comfort of customers. However, most previous researchers focused
3. Energies 2016, 9, 716 3 of 20
on alleviating electricity bills and saving energy without considering the convenience of residential
end users.
In this study, the lightning search algorithm (LSA) is used to improve the ANN for the home
energy management scheduling controller (HEMSC) for the residential DR strategy by modeling the
household appliances. The main contribution of this study focuses on the modeling of household
appliances and developing HEMSC to achieve energy savings in the home on the basis of the
scheduled operation of several appliances according to a specific time. Four appliances, namely,
air conditioner (AC), water heater (WH), refrigerator (REF) and washing machine (WM), are developed
in Matlab/Simulink according to customer preferences and priority of appliances.
2. Load Model of Home Appliances
Load modeling is necessary to evaluate residential DR at the distribution circuit and to study
customer behavior. Thus, specific home appliance models that describe the dynamics of the process
to be controlled are important to design. Determining the operating conditions and characteristics
of household appliances is necessary to develop a HEMSC with residential DR application. In this
study, four selected electrical appliances, namely, AC, WH, WM and REF, are developed using
Matlab/Simulink, as shown in Figure 1.
Energies 2016, 9, 716 3 of 19
In this study, the lightning search algorithm (LSA) is used to improve the ANN for the home
energy management scheduling controller (HEMSC) for the residential DR strategy by modeling the
household appliances. The main contribution of this study focuses on the modeling of household
appliances and developing HEMSC to achieve energy savings in the home on the basis of the
scheduled operation of several appliances according to a specific time. Four appliances, namely, air
conditioner (AC), water heater (WH), refrigerator (REF) and washing machine (WM), are developed
in Matlab/Simulink according to customer preferences and priority of appliances.
2. Load Model of Home Appliances
Load modeling is necessary to evaluate residential DR at the distribution circuit and to study
customer behavior. Thus, specific home appliance models that describe the dynamics of the process
to be controlled are important to design. Determining the operating conditions and characteristics of
household appliances is necessary to develop a HEMSC with residential DR application. In this
study, four selected electrical appliances, namely, AC, WH, WM and REF, are developed using
Matlab/Simulink, as shown in Figure 1.
Figure 1. Block diagram of the proposed home energy management scheduling controller (HEMSC)
system. AC: air conditioner; REF: refrigerator; WM: washing machine; WH: water heater.
The signal of DR is assumed to come from the utility to the smart meter and then to the HEMSC
that includes the amount and duration of load. All appliances can receive a DR signal from the
HEMSC. The power consumptions of WH, AC, WM, and REF are 3, 2.3, 0.6, and 0.15 kW, respectively.
The following subsections describe the model details of home appliances.
2.1. Air Conditioner Modeling
This section presents the AC load model development to produce a load profile at the
distribution circuit level. To calculate the parameters that can be used with a physical‐based AC
model, the mathematical expressions should be derived to obtain an accurate AC load model. The
mathematical model is presented as a set of equations to obtain the relationship between the output
and input parameters, as shown in Figure 2.
The AC unit parameters can be divided into three categories, namely, the characteristics of AC,
the set points of temperatures, and the building structures. The input parameters of the AC model
are the occupant heat gain H , room temperature at time t, , , outside temperature , , set point
temperature , , and the signal of DR , . The model outputs are the room temperature, which
is used as an input to the model at the subsequent step of time and energy consumption. Other
parameters, such as the number of people in the home, room size, solar radiation, season, number of
windows, house area, heat gain rate of the house, and cooling load capacity, should be considered
in Simulink.
HEMSC
AC
WM WH
Smart
meter
UTILITY
REF
Figure 1. Block diagram of the proposed home energy management scheduling controller (HEMSC)
system. AC: air conditioner; REF: refrigerator; WM: washing machine; WH: water heater.
The signal of DR is assumed to come from the utility to the smart meter and then to the HEMSC
that includes the amount and duration of load. All appliances can receive a DR signal from the
HEMSC. The power consumptions of WH, AC, WM, and REF are 3, 2.3, 0.6, and 0.15 kW, respectively.
The following subsections describe the model details of home appliances.
2.1. Air Conditioner Modeling
This section presents the AC load model development to produce a load profile at the
distribution circuit level. To calculate the parameters that can be used with a physical-based AC
model, the mathematical expressions should be derived to obtain an accurate AC load model.
The mathematical model is presented as a set of equations to obtain the relationship between the
output and input parameters, as shown in Figure 2.
The AC unit parameters can be divided into three categories, namely, the characteristics of
AC, the set points of temperatures, and the building structures. The input parameters of the AC
model are the occupant heat gain Hp, room temperature at time t, Tr,t, outside temperature Tout,t,
set point temperature Ts,t, and the signal of DR Snewh,t. The model outputs are the room temperature,
which is used as an input to the model at the subsequent step of time and energy consumption.
Other parameters, such as the number of people in the home, room size, solar radiation, season,
number of windows, house area, heat gain rate of the house, and cooling load capacity, should be
considered in Simulink.
4. Energies 2016, 9, 716 4 of 20
Energies 2016, 9, 716 4 of 19
Power
consumption
Phvac, t
Occupant
heat gain
Hp
Tout temp
Tout, t (°C)
Set point
Temp (Ts)
(°C)
DR signal
(Sn,hvac)
Room temp
Tr,t (°C)
Air
condition
load
Model
(HVAC)
Room temp
Tr,t+1
Figure 2. Flowchart of the AC load model.
In the initial condition, the room temperature at time (t) should be determined based on the
cooling load factor for glass/corrected cooling load temperature difference [24] as follows:
, , d ,
d d
(1)
where is the heat gain rate of the house, , is the room temperature at time t ( ), d is the
length of time slot, d is the energy that changes the air temperature in the Room 1 ), , is
the status of AC in the time slot, and is the cooling load capacity (Btu/ ) [25].
The output room temperature is used as an input room temperature to the AC model at the
following time step. From Equation (1), the heat gain rate of the house, , is expressed as:
, ,
(2)
where is the occupant heat gain (btu/h); is the number of people inside a room; is the
changes in room air in any time slot; , , , are the areas of floor, wall, ceiling, and
window of the dwelling in (m2), respectively; is the solar heat gain coefficient of a window [26];
, , , are the average thermal resistance of the floor, wall, ceiling, and window in
( m2 h/btu), respectively; , is the outside temperature ( ) [27]; _ is the window area facing
south (m2); is the air heat factor (btu/ m ); and is the solar radiation heat power (W/m2).
To change the room temperature by 1 °C to btu/ , the specific heat of air needs to be specified.
The specific heat capacity of air, Cp, is 0.2099/m , and the house volume, , in m , is included
in Equation (3):
d
btu btu
m
m (3)
The amount of AC power consumed in kW with a thermostat operating in OFF or ON mode and
running at its rated power when switched on at a given interval, , , can be expressed as:
, (4)
where is the status of the device; = 1 means that the device is turned on, and =
0 means that the device is turned off. is the AC rated power in kW.
The differences between the set point of AC and the lower or upper limit of the temperatures
are called dead band. If the room temperature decreases below a set point minus the dead band
temperature, then the AC unit is switched OFF. If the room temperature reaches its maximum set
point plus the dead band temperature, then the AC unit is switched ON. However, if the room
temperature is within its tolerable band, then the AC keeps the same status as described
mathematically in Equation (5):
Figure 2. Flowchart of the AC load model.
In the initial condition, the room temperature at time (t) should be determined based on the
cooling load factor for glass/corrected cooling load temperature difference [24] as follows:
Tr,t+1 = Tr,t + dt mhvac,t
Chvac
dc
+
Qt
dc
(1)
where Qt is the heat gain rate of the house, Tr,t is the room temperature at time t (◦C), dt is the length
of time slot, dc is the energy that changes the air temperature in the Room 1 (◦C), mhvac,t is the status
of AC in the time slot, and Chvac is the cooling load capacity (Btu/◦C) [25].
The output room temperature is used as an input room temperature to the AC model at the
following time step. From Equation (1), the heat gain rate of the house, Qt, is expressed as:
Qt = SHGC + Hp × Np
+ Afl
Rfl
+ Awal
Rwal
+ Ace
Rce
+ Awin
Rwin
+ (K × S × Vhos ) × (Tout,t − Tr,t )
+Awins × Hsolar
(2)
where Hp is the occupant heat gain (btu/h); Np is the number of people inside a room; K is the changes
in room air in any time slot; (Afl, Awall, Ace, Awin) are the areas of floor, wall, ceiling, and window of
the dwelling in (m2), respectively; SHGC is the solar heat gain coefficient of a window [26]; ( Rfl, Rwal,
Rce, Awin) are the average thermal resistance of the floor, wall, ceiling, and window in (◦C·m2·h/btu),
respectively; Tout,t is the outside temperature (◦C) [27]; Awin_s is the window area facing south (m2);
S is the air heat factor (btu/◦C·m3); and Hsolar is the solar radiation heat power (W/m2).
To change the room temperature by 1 ◦C to btu/◦C, the specific heat of air needs to be specified.
The specific heat capacity of air, Cp, is 0.2099/m2·◦C, and the house volume, Vhos, in m3, is included in
Equation (3):
dc
btu
◦C
= Cp
btu
m3
◦
C × Vhos m3
(3)
The amount of AC power consumed in kW with a thermostat operating in OFF or ON mode and
running at its rated power when switched on at a given interval, Phavc,t, can be expressed as:
Phvac,t = mhvac × Phvac (4)
where mhvac is the status of the device; mhvac = 1 means that the device is turned on,
and mhvac = 0 means that the device is turned off. Phvac is the AC rated power in kW.
The differences between the set point of AC and the lower or upper limit of the temperatures
are called dead band. If the room temperature decreases below a set point minus the dead band
temperature, then the AC unit is switched OFF. If the room temperature reaches its maximum set point
plus the dead band temperature, then the AC unit is switched ON. However, if the room temperature
5. Energies 2016, 9, 716 5 of 20
is within its tolerable band, then the AC keeps the same status as described mathematically in
Equation (5):
mhvac =
0, Thvac,t < (Ts,t − ∆T)
1, Thvac,t > (Ts,t + ∆T)
mhvac,t−1, Ts,t − ∆T ≤ Thvac,t ≤ Ts,t + ∆T
× Snhvac,t (5)
The electric power demand of the AC load model depends on the DR signal, Snhvac,t. During a DR
event, this signal, which originates from the revised thermostat set point, can be changed by end users.
Ts,t is the set point temperature, and ∆T is the dead band temperature (±2 ◦C).
By using Equations (1), (4) and (5), we simulate the component models of AC and the mathematical
model in Matlab, as shown in Figure 3.
Energies 2016, 9, 716 5 of 19
0, , , ∆
1, , , ∆
, , , ∆ , , ∆
, (5)
The electric power demand of the AC load model depends on the DR signal, , . During a
DR event, this signal, which originates from the revised thermostat set point, can be changed by end
users. , is the set point temperature, and ∆ is the dead band temperature (±2 °C).
By using Equations (1), (4) and (5), we simulate the component models of AC and the
mathematical model in Matlab, as shown in Figure 3.
Figure 3. Matlab block for the simulation model of the AC load model.
2.2. Electric Water Heater Modeling
The electric water heaters (EWHs) are among the major appliances that consume high energy in
residential areas. Energy consumption depends on the amount of hot water that people use at home.
To obtain an accurate model of EWH and to reflect any goal of DR strategies, EWH should be
modeled for use in HEMSC by calculating the input and output parameters, as shown in Figure 4.
Power (Pewh)
Ambient
temp Tam
(°C)
Inlet temp
Tinl (°C)
Set point
temp Tse
(°C)
DR signal
Sn,ewh
Tank temp
Tout,t (°C)
Flow rate
Flr,t
Electric
water
heater
Model
(EWH)
(Tout,t+1)
Figure 4. Flowchart of the electric water heater (EWH) load model. DR: demand response.
A domestic EWH consists of a thermostat to sense temperature and OFF/ON switch to heat
water. The WH parameters can be divided into three categories, namely, the set point temperature,
the use of hot water, and the device characteristics. The input parameters are the ambient
temperature, , water flow rate, , , temperature of inlet water, Tinl, the set point temperature,
, , temperature of water tank, , , and signal of residential DR, , . The model output is the
Figure 3. Matlab block for the simulation model of the AC load model.
2.2. Electric Water Heater Modeling
The electric water heaters (EWHs) are among the major appliances that consume high energy in
residential areas. Energy consumption depends on the amount of hot water that people use at home.
To obtain an accurate model of EWH and to reflect any goal of DR strategies, EWH should be modeled
for use in HEMSC by calculating the input and output parameters, as shown in Figure 4.
Energies 2016, 9, 716 5 of 19
0, , , ∆
1, , , ∆
, , , ∆ , , ∆
, (5)
The electric power demand of the AC load model depends on the DR signal, , . During a
DR event, this signal, which originates from the revised thermostat set point, can be changed by end
users. , is the set point temperature, and ∆ is the dead band temperature (±2 °C).
By using Equations (1), (4) and (5), we simulate the component models of AC and the
mathematical model in Matlab, as shown in Figure 3.
Figure 3. Matlab block for the simulation model of the AC load model.
2.2. Electric Water Heater Modeling
The electric water heaters (EWHs) are among the major appliances that consume high energy in
residential areas. Energy consumption depends on the amount of hot water that people use at home.
To obtain an accurate model of EWH and to reflect any goal of DR strategies, EWH should be
modeled for use in HEMSC by calculating the input and output parameters, as shown in Figure 4.
Power (Pewh)
Ambient
temp Tam
(°C)
Inlet temp
Tinl (°C)
Set point
temp Tse
(°C)
DR signal
Sn,ewh
Tank temp
Tout,t (°C)
Flow rate
Flr,t
Electric
water
heater
Model
(EWH)
(Tout,t+1)
Figure 4. Flowchart of the electric water heater (EWH) load model. DR: demand response.
A domestic EWH consists of a thermostat to sense temperature and OFF/ON switch to heat
water. The WH parameters can be divided into three categories, namely, the set point temperature,
the use of hot water, and the device characteristics. The input parameters are the ambient
temperature, , water flow rate, , , temperature of inlet water, Tinl, the set point temperature,
, , temperature of water tank, , , and signal of residential DR, , . The model output is the
Figure 4. Flowchart of the electric water heater (EWH) load model. DR: demand response.
A domestic EWH consists of a thermostat to sense temperature and OFF/ON switch to heat water.
The WH parameters can be divided into three categories, namely, the set point temperature, the use of
hot water, and the device characteristics. The input parameters are the ambient temperature, Tamp,
6. Energies 2016, 9, 716 6 of 20
water flow rate, Flr,t, temperature of inlet water, Tinl, the set point temperature, Tse,t, temperature of
water tank, Tout,t, and signal of residential DR, Snewh,t. The model output is the temperature of the
EWH tank that is used as an input to the model at the subsequent step of time and power consumption.
The data for the EWH model depends on additional parameters, such as the surface area of
storage tank WH, cross-sectional area, and volume that contribute to the design of accurate models.
In the initial condition, the water temperature at time (t) of the EWH should be calculated based
on the usage pattern [25]. First, the outlet water temperature of the tank is considered, which is
expressed as
Tout,t+1 =
Tout,t×(Voltank−V×dt)+Tinl×Flr,t×dt
Voltank
+ dt
60
×
Pewh,t
Voltank
3412 BTU
kwh −
Atank×(Tout,t−Tamp)
Rtank
(6)
where Tinl is the inlet water temperature (◦C), Flr,t is the hot water flow rate at a given interval (m3/s),
Voltank is the volume of the tank (m3), Atank is the surface area of the tank, Tamp is the ambient
temperature, Rtank is the heat resistance of the tank (◦C·m3·h/btu), and dt is the duration of the time
slot t.
The differences between the set point lower and upper limits of the tank temperature are called
dead band. If the water tank temperature drops below the set point lower limit minus the dead band
temperature range, then the EWH coils are switched ON. If the water tank temperature is raised to its
set point upper limit plus the dead band temperature, then the heating coils of EWH are switched OFF.
The EWH operation depends on the device status, mewh, which is mathematically expressed as:
mewh =
1, Tewh,t < Tse,t − ∆T
0, Tewh,t > Tse,t + ∆T
mewh,t−1, Tse,t − ∆T ≤ Tewh,t ≤ Tse,t + ∆T
× Snewh,t (7)
where Snewh,t is the DR signal, Tse,t is the set point temperature, and ∆T is the dead band temperature
(±2 ◦C). The electric power demand of the EWH load model depends on the DR signal Snewh,t.
The amount of EWH power consumed in kW depends on the thermostat that operates in the
OFF/ON states and runs at its rated power [28]. The power of EWH at a given time is calculated by:
Pewh,t = mewh × Pewh (8)
where mewh is the status of the device; and mewh = 1 means that the device is switched on,
and mewh = 0 means that the device is switched off. Pewh is the EWH rated power in kW.
By using Equations (6)–(8), we simulate the component models of EWH and the mathematical
model in Matlab, as shown in Figure 5.
Energies 2016, 9, 716 6 of 19
temperature of the EWH tank that is used as an input to the model at the subsequent step of time and
power consumption.
The data for the EWH model depends on additional parameters, such as the surface area of
storage tank WH, cross‐sectional area, and volume that contribute to the design of accurate models.
In the initial condition, the water temperature at time (t) of the EWH should be calculated based
on the usage pattern [25]. First, the outlet water temperature of the tank is considered, which is
expressed as
,
, d , d d
60
, 3412 BTU
kwh
,
(6)
where is the inlet water temperature ( ), , is the hot water flow rate at a given interval
(m3/s), is the volume of the tank (m3), is the surface area of the tank, is the
ambient temperature, is the heat resistance of the tank ( m3 h/btu), and dt is the duration of
the time slot t.
The differences between the set point lower and upper limits of the tank temperature are called
dead band. If the water tank temperature drops below the set point lower limit minus the dead band
temperature range, then the EWH coils are switched ON. If the water tank temperature is raised to
its set point upper limit plus the dead band temperature, then the heating coils of EWH are switched
OFF. The EWH operation depends on the device status, , which is mathematically expressed as:
1, , , ∆
0, , , ∆
, , , ∆ , , ∆
, (7)
where , is the DR signal, , is the set point temperature, and ∆ is the dead band
temperature (±2 ). The electric power demand of the EWH load model depends on the DR signal
, .
The amount of EWH power consumed in kW depends on the thermostat that operates in the
OFF/ON states and runs at its rated power [28]. The power of EWH at a given time is calculated by:
, (8)
where is the status of the device; and = 1 means that the device is switched on, and
= 0 means that the device is switched off. is the EWH rated power in kW.
By using Equations (6)–(8), we simulate the component models of EWH and the mathematical
model in Matlab, as shown in Figure 5.
Figure 5. Matlab block for the simulation model of the EWH load model.
Figure 5. Matlab block for the simulation model of the EWH load model.
7. Energies 2016, 9, 716 7 of 20
During a DR event, the signal, which originates from the revised thermostat set point, can be
changed by the homeowner. The data for the EWH model depend on the storage tank WH and other
parameters that contribute to the design of the EWH physical model.
2.3. Water Heater and Refrigerator Modeling
WM is a home appliance operated by a motor connected to the agitator through a unit called
transmission. WMs are divided into two categories depending on the positioning of their axis, namely,
vertical axis WM and horizontal axis WM. The power consumption of WM at the residential sector
accounts for approximately 7.2% of the total electricity consumption [29] and usually consists of
an induction motor. In addition, the main electrical component of REF is the compressor, which is
again an induction motor. Many different approaches are used to model the WM and REF. Real data are
measured by using a power quality analyzer to obtain accurate WM and REF models. Matlab/Simulink
is developed using resistors and reactance, as shown in Figures 6 and 7, for WM and REF, respectively.
Energies 2016, 9, 716 7 of 19
During a DR event, the signal, which originates from the revised thermostat set point, can be
changed by the homeowner. The data for the EWH model depend on the storage tank WH and other
parameters that contribute to the design of the EWH physical model.
2.3. Water Heater and Refrigerator Modeling
WM is a home appliance operated by a motor connected to the agitator through a unit called
transmission. WMs are divided into two categories depending on the positioning of their axis,
namely, vertical axis WM and horizontal axis WM. The power consumption of WM at the residential
sector accounts for approximately 7.2% of the total electricity consumption [29] and usually consists
of an induction motor. In addition, the main electrical component of REF is the compressor, which is
again an induction motor. Many different approaches are used to model the WM and REF. Real data
are measured by using a power quality analyzer to obtain accurate WM and REF models.
Matlab/Simulink is developed using resistors and reactance, as shown in Figures 6 and 7, for WM
and REF, respectively.
Figure 6. Simulation model of WM.
Figure 7. Simulation model of REF.
The rated power of WM depends on the stage of washing cycles, including washing, rinsing,
and spinning, which last typically 55 min to finish the WM job at full load with 53 L of water.
Figure 6. Simulation model of WM.
Energies 2016, 9, 716 7 of 19
During a DR event, the signal, which originates from the revised thermostat set point, can be
changed by the homeowner. The data for the EWH model depend on the storage tank WH and other
parameters that contribute to the design of the EWH physical model.
2.3. Water Heater and Refrigerator Modeling
WM is a home appliance operated by a motor connected to the agitator through a unit called
transmission. WMs are divided into two categories depending on the positioning of their axis,
namely, vertical axis WM and horizontal axis WM. The power consumption of WM at the residential
sector accounts for approximately 7.2% of the total electricity consumption [29] and usually consists
of an induction motor. In addition, the main electrical component of REF is the compressor, which is
again an induction motor. Many different approaches are used to model the WM and REF. Real data
are measured by using a power quality analyzer to obtain accurate WM and REF models.
Matlab/Simulink is developed using resistors and reactance, as shown in Figures 6 and 7, for WM
and REF, respectively.
Figure 6. Simulation model of WM.
Figure 7. Simulation model of REF.
The rated power of WM depends on the stage of washing cycles, including washing, rinsing,
and spinning, which last typically 55 min to finish the WM job at full load with 53 L of water.
Figure 7. Simulation model of REF.
The rated power of WM depends on the stage of washing cycles, including washing, rinsing,
and spinning, which last typically 55 min to finish the WM job at full load with 53 L of water.
8. Energies 2016, 9, 716 8 of 20
3. Gathering Data for Household Appliance Models
Data were obtained in December 2015 by using a power quality analyzer to measure the power
consumption of AC, WH, WM, and REF as shown in Figure 8 by considering a sample apartment
house in the town of Kajang, Malaysia as a case study.
Energies 2016, 9, 716 8 of 19
3. Gathering Data for Household Appliance Models
Data were obtained in December 2015 by using a power quality analyzer to measure the power
consumption of AC, WH, WM, and REF as shown in Figure 8 by considering a sample apartment
house in the town of Kajang, Malaysia as a case study.
Figure 8. Power quality analyzer to measure the power consumption.
The input physical model of AC considered three important factors, namely, AC characteristics,
temperature, and building characteristics. The temperature consisted of outdoor and indoor set
points. The outside temperature was measured by a temperature and humidity sensor wireless data
logger connected inside and outside residences, as shown in Figure 9.
Figure 9. Temperature and humidity wireless data logger.
Solar irradiation (H solar) was measured by using the Apogee Instruments pyranometer. The
pyranometer is a silicon cell that is sensitive to a portion of the solar spectrum that estimates the total
radiation across the entire solar spectrum, as shown in Figure 10. The REF data were obtained with a
freezer temperature of −18 and refrigerator temperature of 3 , as shown in Figure 11. Thermal
mass in the freezer and REF was combined and includes five bottles of water, two chickens, and 6 kg
of fruits and vegetables in the REF at a working time of 24 h. The simulation model output result of
REF after calculating the equivalent circuit of the motor depended on the measured data.
Figure 10. Apogee Instruments pyranometer solar radiation sensors.
Figure 8. Power quality analyzer to measure the power consumption.
The input physical model of AC considered three important factors, namely, AC characteristics,
temperature, and building characteristics. The temperature consisted of outdoor and indoor set points.
The outside temperature was measured by a temperature and humidity sensor wireless data logger
connected inside and outside residences, as shown in Figure 9.
Energies 2016, 9, 716 8 of 19
3. Gathering Data for Household Appliance Models
Data were obtained in December 2015 by using a power quality analyzer to measure the power
consumption of AC, WH, WM, and REF as shown in Figure 8 by considering a sample apartment
house in the town of Kajang, Malaysia as a case study.
Figure 8. Power quality analyzer to measure the power consumption.
The input physical model of AC considered three important factors, namely, AC characteristics,
temperature, and building characteristics. The temperature consisted of outdoor and indoor set
points. The outside temperature was measured by a temperature and humidity sensor wireless data
logger connected inside and outside residences, as shown in Figure 9.
Figure 9. Temperature and humidity wireless data logger.
Solar irradiation (H solar) was measured by using the Apogee Instruments pyranometer. The
pyranometer is a silicon cell that is sensitive to a portion of the solar spectrum that estimates the total
radiation across the entire solar spectrum, as shown in Figure 10. The REF data were obtained with a
freezer temperature of −18 and refrigerator temperature of 3 , as shown in Figure 11. Thermal
mass in the freezer and REF was combined and includes five bottles of water, two chickens, and 6 kg
of fruits and vegetables in the REF at a working time of 24 h. The simulation model output result of
REF after calculating the equivalent circuit of the motor depended on the measured data.
Figure 10. Apogee Instruments pyranometer solar radiation sensors.
Figure 9. Temperature and humidity wireless data logger.
Solar irradiation (H solar) was measured by using the Apogee Instruments pyranometer.
The pyranometer is a silicon cell that is sensitive to a portion of the solar spectrum that estimates the
total radiation across the entire solar spectrum, as shown in Figure 10. The REF data were obtained
with a freezer temperature of −18 ◦C and refrigerator temperature of 3 ◦C, as shown in Figure 11.
Thermal mass in the freezer and REF was combined and includes five bottles of water, two chickens,
and 6 kg of fruits and vegetables in the REF at a working time of 24 h. The simulation model output
result of REF after calculating the equivalent circuit of the motor depended on the measured data.
Energies 2016, 9, 716 8 of 19
3. Gathering Data for Household Appliance Models
Data were obtained in December 2015 by using a power quality analyzer to measure the power
consumption of AC, WH, WM, and REF as shown in Figure 8 by considering a sample apartment
house in the town of Kajang, Malaysia as a case study.
Figure 8. Power quality analyzer to measure the power consumption.
The input physical model of AC considered three important factors, namely, AC characteristics,
temperature, and building characteristics. The temperature consisted of outdoor and indoor set
points. The outside temperature was measured by a temperature and humidity sensor wireless data
logger connected inside and outside residences, as shown in Figure 9.
Figure 9. Temperature and humidity wireless data logger.
Solar irradiation (H solar) was measured by using the Apogee Instruments pyranometer. The
pyranometer is a silicon cell that is sensitive to a portion of the solar spectrum that estimates the total
radiation across the entire solar spectrum, as shown in Figure 10. The REF data were obtained with a
freezer temperature of −18 and refrigerator temperature of 3 , as shown in Figure 11. Thermal
mass in the freezer and REF was combined and includes five bottles of water, two chickens, and 6 kg
of fruits and vegetables in the REF at a working time of 24 h. The simulation model output result of
REF after calculating the equivalent circuit of the motor depended on the measured data.
Figure 10. Apogee Instruments pyranometer solar radiation sensors.
Figure 10. Apogee Instruments pyranometer solar radiation sensors.
9. Energies 2016, 9, 716 9 of 20
Energies 2016, 9, 716 9 of 19
Figure 11. REF power consumption measurement.
Each case of washing, rinsing and spinning has different power consumptions. By contrast, the
REF power consumption depends on two cases: the first case has doors closed, and the second case
denotes frequent opening of the doors. The temperature settings on the REF and freezer are 3 °C and
−18 °C, respectively.
To simulate the model in Matlab, the equivalent circuit of MW and REF should be calculated to
reflect the behavior of the real operation and to obtain an accurate result for both appliances. The
equivalent circuit of the motor can be represented as impedances, as shown in Figure 12.
Figure 12. Equivalent circuit of WM and REF.
4. Artificial Intelligent Techniques Used for Home Energy Management Scheduling Controller
In this section, ANN, LSA, and the proposed hybrid LSA‐ANN are discussed.
4.1. Artificial Neural Network Technique
An ANN is an information processing paradigm that models nonlinear systems and attempts to
simulate the functionality of the human brain. Neural networks have many unique benefits,
especially with the complex nonlinear relationships between system input and output, which handle
any complex nonlinear functions through training and learning system input and output.
In this study, a feed‐forward neural network type and the Levenberg–Marquardt training
algorithm are selected for training the ANN in the Matlab toolbox. The ANN structure consists of
five inputs ( , , , , DR), two hidden layers with the activation function as sigmoid
function, and four outputs (AC, WH, WM, and REF). The actual data are collected from the
simulation system, which represents the training data of the ANN, as shown in Figure 13.
Figure 11. REF power consumption measurement.
Each case of washing, rinsing and spinning has different power consumptions. By contrast,
the REF power consumption depends on two cases: the first case has doors closed, and the second
case denotes frequent opening of the doors. The temperature settings on the REF and freezer are 3 ◦C
and −18 ◦C, respectively.
To simulate the model in Matlab, the equivalent circuit of MW and REF should be calculated
to reflect the behavior of the real operation and to obtain an accurate result for both appliances.
The equivalent circuit of the motor can be represented as impedances, as shown in Figure 12.
Energies 2016, 9, 716 9 of 19
Figure 11. REF power consumption measurement.
Each case of washing, rinsing and spinning has different power consumptions. By contrast, the
REF power consumption depends on two cases: the first case has doors closed, and the second case
denotes frequent opening of the doors. The temperature settings on the REF and freezer are 3 °C and
−18 °C, respectively.
To simulate the model in Matlab, the equivalent circuit of MW and REF should be calculated to
reflect the behavior of the real operation and to obtain an accurate result for both appliances. The
equivalent circuit of the motor can be represented as impedances, as shown in Figure 12.
Figure 12. Equivalent circuit of WM and REF.
4. Artificial Intelligent Techniques Used for Home Energy Management Scheduling Controller
In this section, ANN, LSA, and the proposed hybrid LSA‐ANN are discussed.
4.1. Artificial Neural Network Technique
An ANN is an information processing paradigm that models nonlinear systems and attempts to
simulate the functionality of the human brain. Neural networks have many unique benefits,
especially with the complex nonlinear relationships between system input and output, which handle
any complex nonlinear functions through training and learning system input and output.
In this study, a feed‐forward neural network type and the Levenberg–Marquardt training
algorithm are selected for training the ANN in the Matlab toolbox. The ANN structure consists of
five inputs ( , , , , DR), two hidden layers with the activation function as sigmoid
function, and four outputs (AC, WH, WM, and REF). The actual data are collected from the
simulation system, which represents the training data of the ANN, as shown in Figure 13.
Figure 12. Equivalent circuit of WM and REF.
4. Artificial Intelligent Techniques Used for Home Energy Management Scheduling Controller
In this section, ANN, LSA, and the proposed hybrid LSA-ANN are discussed.
4.1. Artificial Neural Network Technique
An ANN is an information processing paradigm that models nonlinear systems and attempts
to simulate the functionality of the human brain. Neural networks have many unique benefits,
especially with the complex nonlinear relationships between system input and output, which handle
any complex nonlinear functions through training and learning system input and output.
In this study, a feed-forward neural network type and the Levenberg–Marquardt training
algorithm are selected for training the ANN in the Matlab toolbox. The ANN structure consists
of five inputs (Tac, Twh, Tot , Tim , DR), two hidden layers with the activation function as sigmoid
function, and four outputs (AC, WH, WM, and REF). The actual data are collected from the simulation
system, which represents the training data of the ANN, as shown in Figure 13.
10. Energies 2016, 9, 716 10 of 20
Energies 2016, 9, 716 10 of 19
Tac
1
2
3
4
5
6
N
1
2
3
4
5
6
M
Input layer Hidden layer1 Hidden layer 2 Output layer
Twh
Tot
WH
AC
WM
Tim REF
DR
Figure 13. Architecture of the artificial neural network (ANN) algorithm.
All inputs and outputs of ANN‐based HEMSC can be expressed by Equations (9) and (10):
Input
DL
DL
:
:
DL
(9)
Output
AC WH REF WM
AC WH REF WM
:
:
AC WH REF WM
(10)
where denotes the room temperature ( ); is the WH temperature; is the total power
consumption; denotes the time of the system; and DR is the signal of a DR event.
In this system, the DR starts from between 16 h and 23 h, and the value of demand limit (DL) is
assumed to be 3 kW. If is higher than DL, then the controller will switch OFF the lower priority
appliance; otherwise, the system works normally. The and of the system are used to
evaluate the comfort level of the end users for AC and WH, respectively. The outputs of the ANN are
the signals to turn the four home appliances ON or OFF according to customer preferences, comfort
level, and priority of appliances. Sudden changes in the home appliances can be predicted by using ANN.
4.2. Overview of Lightning Search Algorithm
Optimization is a process to find the best solution to problems depending on the input variables
after determining the objective function subjected to constraints. The objective function is often
formulated based on a certain application and can take the form of minimal error, minimal cost,
optimal design, and optimal management. LSA is a new optimization algorithm based on the natural
phenomenon of lightning [29], and it is inspired by the probabilistic nature and sinuous
characteristics of lightning discharges during a thunderstorm. LSA is organized from the mechanism
of step leader propagation. This algorithm considers the participation of fast particles (projectiles) in
the figuration of the binary tree structure of a step leader. Similar to other metaheuristic algorithms,
LSA also needs a population to begin the search. The projectile suggests random solutions for
corresponding problems to be solved by LSA. More details about LSA and basic ideas can be found
in [30,31]. The step leaders are formed in the first phase because transition projectiles are ejected from
the thunder cell in a random direction. Thus, the formula of uniform probability distribution is used
for a random number of step leaders. The standard uniform distribution can be formulated as follows:
1
b a
, for a b
0, elsewhere
(11)
Figure 13. Architecture of the artificial neural network (ANN) algorithm.
All inputs and outputs of ANN-based HEMSC can be expressed by Equations (9) and (10):
Input =
Tac1 Twh1 Tot1 Tim1 DL1
Tac2 Twh2 Tot2Tim2 DL2
:
:
Tacn Twhn TotnTimn DLn
(9)
Output =
AC1 WH1 REF1 WM1
AC2 WH2 REF2 WM2
:
:
ACn WHn REFn WMn
(10)
where Tac denotes the room temperature (◦C); Twh is the WH temperature; Tot is the total power
consumption; Tim denotes the time of the system; and DR is the signal of a DR event.
In this system, the DR starts from between 16 h and 23 h, and the value of demand limit (DL) is
assumed to be 3 kW. If Tot is higher than DL, then the controller will switch OFF the lower priority
appliance; otherwise, the system works normally. The Tac and Twh of the system are used to evaluate
the comfort level of the end users for AC and WH, respectively. The outputs of the ANN are the
signals to turn the four home appliances ON or OFF according to customer preferences, comfort level,
and priority of appliances. Sudden changes in the home appliances can be predicted by using ANN.
4.2. Overview of Lightning Search Algorithm
Optimization is a process to find the best solution to problems depending on the input variables
after determining the objective function subjected to constraints. The objective function is often
formulated based on a certain application and can take the form of minimal error, minimal cost,
optimal design, and optimal management. LSA is a new optimization algorithm based on the natural
phenomenon of lightning [29], and it is inspired by the probabilistic nature and sinuous characteristics
of lightning discharges during a thunderstorm. LSA is organized from the mechanism of step leader
propagation. This algorithm considers the participation of fast particles (projectiles) in the figuration
of the binary tree structure of a step leader. Similar to other metaheuristic algorithms, LSA also
needs a population to begin the search. The projectile suggests random solutions for corresponding
problems to be solved by LSA. More details about LSA and basic ideas can be found in [30,31]. The step
leaders are formed in the first phase because transition projectiles are ejected from the thunder cell
in a random direction. Thus, the formula of uniform probability distribution is used for a random
number of step leaders. The standard uniform distribution can be formulated as follows:
11. Energies 2016, 9, 716 11 of 20
f xT
=
1
(b−a)
, for a < xT ≤ b
0, elsewhere
(11)
where xT is a random number that may provide a solution; and a and b are the lower and upper
bounds of the solution space, respectively. The probability density function f (xs) of an exponential
distribution [31] is shown by Equation (12):
f (xs
) =
1
µ e
( xs
(µ)
)
, for xs ≥ b
0 , for xs ≤ b
(12)
After the initial is evaluated, the position and direction are updated with Equation (13):
ps
i−NEW = ps
i ± exprand (µi) (13)
where ps
i−NEW is the new projectile, and ps
i is the old projectile.
The projectiles and the step leaders that have traveled close to the ground do not have adequate
potential to ionize large sections in front of the leading edge. In this way, the lead projectile can be
formulated as a random number taken from the standard normal distribution. The normal probability
density function f (xL) is expressed as:
f (xL
) =
1
σ
√
2π
e−( xL−µ)
2
/2σ2
(14)
where f (xL) is the normal probability density function, σ is the scale parameter, and µ is the
shape parameter.
From Equation (14), the randomly generated lead projectile can search in all directions from the
current position defined by the shape parameter. The scale parameter σ decreases exponentially to
find the best solution. Therefore, the position of pL in step + 1 can be shown in Equation (15) [31]:
pL
NEW = pL
+ normrand (µL, σL) (15)
where pL
NEW is the new lead projectile.
4.3. Proposed Hybrid Lightning Search Algorithm-Based Artificial Neural Network
The ANN algorithm can be used to control the appliances in HEMSC. The comfort level of end
users can be utilized as the inputs of the ANN to determine and improve the suitable ON/OFF status
of appliances and schedule another time without affecting the convenience of end users in the devices.
The learning rate and the neurons in each hidden layer in the ANN architecture are the significant
parameters. However, the selection of the learning rate and the neurons are subject to trial-and-error
processes, which do not give the optimal solution. LSA addresses such a problem to enhance the ANN
performance by finding the optimum learning rate and the best value of neurons in each hidden layer of
the neural network that can be used in home energy scheduler controller. The implementation starts by
resetting the LSA parameters, namely, number of iterations (T), population size (N), problem dimension
(D), and channel time. Each step leader in this algorithm contains three components, namely, learning
rate (LR), number of neurons in the first hidden layer (N1), and number of neurons in the second
hidden layer (N2). The obtained values of LR, N1 and N2 are used in the ANN training to minimize
the error of ON/OFF devices status in HEMSC. The flow chart of the proposed hybrid LSA-ANN
12. Energies 2016, 9, 716 12 of 20
is shown in Figure 14. The mean absolute error (MAE) is used as objective function to improve the
performance of the ANN by minimizing the error function, as shown in the following equation:
MAE =
n
∑
i = 1
1
n
(error)2
(16)
where error = sa − se, sa is the actual status, se is the estimated status of HEMSC, and m is the number
of samples.Energies 2016, 9, 716 12 of 19
Start
Reset LSA parameters: number of iteration (T),
size of the population (N), number of problem
dimension (D), channel time
Yes
j = j + 1
Generate initial population of step leaders
Reach maximum
channel time?
Eliminate bad channel
(Move step leader from
worst to best)
Reset channel time
Update kinetic energy, Ep and Update direction
Yes i > N
Reach maximum step leaders?
Extend channel
(Ep>Esl)?
Remain position
Forking
occur?
New position
Create two symmetrical
channels at fork point
Eliminate channel which
has lower energy
Yes
No
Yes
No
Yes
No
t > T
Reach maximum iteration?
Update best and worst step leaders
Calculate distance (dist) between populations
No
j > D
Reach maximum problem dimension?
(dist) = 0
Update position using Eq.(15)
Yes No
Yes
No
Check the boundary control mechanism for new position
t = t + 1
No
Update position using Eq.(13)
Choice N1, N2, LR and Run ANN
Calculate objective function (MAE) for each
step leader (Pij) using Eq. (16)
i > N
Reach Maximum population?
No
Yes
i=i+1
Output the optimal N1, N2 and LR
Choice N1, N2, LR and
Run ANN
Calculate objective function
(MAE) for each step leader
(Pij) using Eq. (16)
i = i + 1
Figure 14. Flowchart of the proposed hybrid LSA‐ANN.
5. Overall Proposed Home Energy Management Scheduling Controller System
The proposed HEMSC algorithm is developed such that it can control and schedule the WH,
AC, WM and REF, and switch customer load to decrease the costs of electrical power consumption
during DR event. The HEMSC algorithm starts by reading the data and information of all the above‐
mentioned appliances. Each appliance is compared on several set points, including load priority,
power consumption, and customer preference, by settings on the room temperature of AC and the
water temperature of WH. The entire system is implemented by Matlab/Simulink, as shown in Figure 15.
Figure 14. Flowchart of the proposed hybrid LSA-ANN.
5. Overall Proposed Home Energy Management Scheduling Controller System
The proposed HEMSC algorithm is developed such that it can control and schedule the WH,
AC, WM and REF, and switch customer load to decrease the costs of electrical power consumption
during DR event. The HEMSC algorithm starts by reading the data and information of all the
13. Energies 2016, 9, 716 13 of 20
above-mentioned appliances. Each appliance is compared on several set points, including load
priority, power consumption, and customer preference, by settings on the room temperature of AC
and the water temperature of WH. The entire system is implemented by Matlab/Simulink, as shown
in Figure 15.Energies 2016, 9, 716 13 of 19
Figure 15. Matlab block implementation for the simulation model of the overall system.
6. Results and Discussion
This section describes the results of the simulation models of the home appliances with experimental
results and the hybrid LSA‐ANN results for the home energy management scheduling controller.
6.1. Home Appliance Simulation Result
The following subsections describe the simulation model results of the modeled home appliances.
6.1.1. Water Heater Simulation Result
A case study is conducted to illustrate the performance model of the WH. This case study shows
the hot water usage of WH at different times, as in Figure 16a. In Figure 16b, the maximum
temperature is assumed to be 48 °C, and the minimum temperature of the WH setting is assumed to
be 42 °C. These values can be altered in the physical model according to the preference of customers.
(a) (b)
Figure 16. Simulation model of EWH load: (a) flow rate of the hot water in gpm; and (b) hot water
temperature within 42–48 °C with the power consumption pattern.
When the hot water is used at 7:00 a.m. and the temperature reaches its minimum allowable set
point of 42 , the WH will switch ON to keep the water temperature at its comfortable range. When
the hot water is used between 4:00 p.m. and 6:00 p.m., the WH will switch ON again to maintain the
water temperature in the tank until the temperature reaches its maximum allowable set point of 48
, to switch OFF the WH. When the temperature of the water in the tank is within 42–48 , the
heater switch status will maintain the previous device state.
Figure 15. Matlab block implementation for the simulation model of the overall system.
6. Results and Discussion
This section describes the results of the simulation models of the home appliances with
experimental results and the hybrid LSA-ANN results for the home energy management
scheduling controller.
6.1. Home Appliance Simulation Result
The following subsections describe the simulation model results of the modeled home appliances.
6.1.1. Water Heater Simulation Result
A case study is conducted to illustrate the performance model of the WH. This case study shows
the hot water usage of WH at different times, as in Figure 16a. In Figure 16b, the maximum temperature
is assumed to be 48 ◦C, and the minimum temperature of the WH setting is assumed to be 42 ◦C.
These values can be altered in the physical model according to the preference of customers.
Energies 2016, 9, 716 13 of 19
Figure 15. Matlab block implementation for the simulation model of the overall system.
6. Results and Discussion
This section describes the results of the simulation models of the home appliances with experimental
results and the hybrid LSA‐ANN results for the home energy management scheduling controller.
6.1. Home Appliance Simulation Result
The following subsections describe the simulation model results of the modeled home appliances.
6.1.1. Water Heater Simulation Result
A case study is conducted to illustrate the performance model of the WH. This case study shows
the hot water usage of WH at different times, as in Figure 16a. In Figure 16b, the maximum
temperature is assumed to be 48 °C, and the minimum temperature of the WH setting is assumed to
be 42 °C. These values can be altered in the physical model according to the preference of customers.
(a) (b)
Figure 16. Simulation model of EWH load: (a) flow rate of the hot water in gpm; and (b) hot water
temperature within 42–48 °C with the power consumption pattern.
When the hot water is used at 7:00 a.m. and the temperature reaches its minimum allowable set
point of 42 , the WH will switch ON to keep the water temperature at its comfortable range. When
the hot water is used between 4:00 p.m. and 6:00 p.m., the WH will switch ON again to maintain the
water temperature in the tank until the temperature reaches its maximum allowable set point of 48
, to switch OFF the WH. When the temperature of the water in the tank is within 42–48 , the
Figure 16. Simulation model of EWH load: (a) flow rate of the hot water in gpm; and (b) hot water
temperature within 42–48 ◦C with the power consumption pattern.
14. Energies 2016, 9, 716 14 of 20
When the hot water is used at 7:00 a.m. and the temperature reaches its minimum allowable
set point of 42 ◦C, the WH will switch ON to keep the water temperature at its comfortable range.
When the hot water is used between 4:00 p.m. and 6:00 p.m., the WH will switch ON again to maintain
the water temperature in the tank until the temperature reaches its maximum allowable set point
of 48 ◦C, to switch OFF the WH. When the temperature of the water in the tank is within 42–48 ◦C,
the heater switch status will maintain the previous device state.
6.1.2. Air Conditioner Simulation Results
In the simulation, the maximum and minimum temperatures of AC are set at 28 ◦C and 18 ◦C,
respectively. These values can be changed in the physical model according to the preference of the
customer. Real data are measured to be used as input for the AC load model that includes the H
solar and outside temperature, both of which are measured in Kajang, Malaysia. According to the
homeowner comfort setting of the room temperature, which is set between 28 ◦C and 18 ◦C, the AC
Simulink is shown in Figure 17.
Energies 2016, 9, 716 14 of 19
6.1.2. Air Conditioner Simulation Results
In the simulation, the maximum and minimum temperatures of AC are set at 28 °C and 18 ,
respectively. These values can be changed in the physical model according to the preference of the
customer. Real data are measured to be used as input for the AC load model that includes the H solar
and outside temperature, both of which are measured in Kajang, Malaysia. According to the
homeowner comfort setting of the room temperature, which is set between 28 °C and 18 , the AC
Simulink is shown in Figure 17.
Figure 17. Simulation model of AC power consumption pattern with room temperature.
Figure 17 shows that if the room temperature reaches its minimum set point temperature of 18
, then the AC is switched OFF. When the room temperature reaches its maximum set point
temperature of 28 , then the AC is switched ON to keep the room temperature in its comfortable
range. When the room temperature is within 18–28 , the switch status will maintain the previous
device state.
6.2. Experimental Measurement Data
The temperatures outside and inside the building were measured by using a wireless data logger
sensor, and the measured outdoor temperature is shown in Figure 18. The solar irradiation was
measured using the Apogee instrument pyranometer sensors and the measured data are shown in
Figure 19. Both the temperature and solar irradiation were used as inputs to the AC model.
Figure 18. Measured outdoor temperature.
0 2 4 6 8 10 12 14 16 18 20 22 24
5
10
15
20
25
30
Time ( hour)
Temperature,C
0
1
2
3
4
5
6
Powerconsumption(kW)
0 2 4 6 8 10 12 14 16 18 20 22 24
24
26
28
30
32
34
36
Time (hour)
Temperature,C
Temp
400
600
800
1000
radiation(w/m2
)
H solar
Figure 17. Simulation model of AC power consumption pattern with room temperature.
Figure 17 shows that if the room temperature reaches its minimum set point temperature of 18 ◦C,
then the AC is switched OFF. When the room temperature reaches its maximum set point temperature
of 28 ◦C, then the AC is switched ON to keep the room temperature in its comfortable range. When the
room temperature is within 18–28 ◦C, the switch status will maintain the previous device state.
6.2. Experimental Measurement Data
The temperatures outside and inside the building were measured by using a wireless data logger
sensor, and the measured outdoor temperature is shown in Figure 18. The solar irradiation was
measured using the Apogee instrument pyranometer sensors and the measured data are shown in
Figure 19. Both the temperature and solar irradiation were used as inputs to the AC model.
Energies 2016, 9, 716 14 of 19
6.1.2. Air Conditioner Simulation Results
In the simulation, the maximum and minimum temperatures of AC are set at 28 °C and 18 ,
respectively. These values can be changed in the physical model according to the preference of the
customer. Real data are measured to be used as input for the AC load model that includes the H solar
and outside temperature, both of which are measured in Kajang, Malaysia. According to the
homeowner comfort setting of the room temperature, which is set between 28 °C and 18 , the AC
Simulink is shown in Figure 17.
Figure 17. Simulation model of AC power consumption pattern with room temperature.
Figure 17 shows that if the room temperature reaches its minimum set point temperature of 18
, then the AC is switched OFF. When the room temperature reaches its maximum set point
temperature of 28 , then the AC is switched ON to keep the room temperature in its comfortable
range. When the room temperature is within 18–28 , the switch status will maintain the previous
device state.
6.2. Experimental Measurement Data
The temperatures outside and inside the building were measured by using a wireless data logger
sensor, and the measured outdoor temperature is shown in Figure 18. The solar irradiation was
measured using the Apogee instrument pyranometer sensors and the measured data are shown in
Figure 19. Both the temperature and solar irradiation were used as inputs to the AC model.
Figure 18. Measured outdoor temperature.
0 2 4 6 8 10 12 14 16 18 20 22 24
5
10
15
20
25
30
Time ( hour)
Temperature,C
0
1
2
3
4
5
6
Powerconsumption(kW)
0 2 4 6 8 10 12 14 16 18 20 22 24
24
26
28
30
32
34
36
Time (hour)
Temperature,C
Temp
200
400
600
800
1000
Solarirradiation(w/m2
)
H solar
Figure 18. Measured outdoor temperature.
15. Energies 2016, 9, 716 15 of 20
Figure 18. Measured outdoor temperature.
Figure 19. Measured solar irradiation data.
Other data from WM and REF power consumption were also considered. According to the real
measurement of WM, 55.5 min was needed to complete the job with three different energy
0 2 4 6 8 10 12 14 16 18 20 22 24
24
26
28
30
Time (hour)
Temper
0 2 4 6 8 10 12 14 16 18 20 22 24
0
200
400
600
800
1000
Time (hour)
Solarirradiation(w/m2
)
H solar
Figure 19. Measured solar irradiation data.
Other data from WM and REF power consumption were also considered. According to the real
measurement of WM, 55.5 min was needed to complete the job with three different energy consumption
levels during washing, rinsing, and spinning. In the washing cycle, three intervals at 11.5, 2.25 and
2.5 min were needed to finish the task. In the rinsing cycle, three duration times were needed to
finish the job, with a 1 min interval. Finally, the last cycle needed 2.5, 2.5 and 6min to complete the
job. The experimental measurement data of the WM power consumption are shown in Figure 20.
The power consumption curve of the REF was measured every minute, as shown in Figure 21.
Energies 2016, 9, 716 15 of 19
consumption levels during washing, rinsing, and spinning. In the washing cycle, three intervals at
11.5, 2.25 and 2.5 min were needed to finish the task. In the rinsing cycle, three duration times were
needed to finish the job, with a 1 min interval. Finally, the last cycle needed 2.5, 2.5 and 6min to
complete the job. The experimental measurement data of the WM power consumption are shown in
Figure 20. The power consumption curve of the REF was measured every minute, as shown in Figure 21.
Figure 20. Actual power consumption curve of WM load.
Figure 21. Actual power consumption curve of REF load.
6.3. Results of the Hybrid Lightning Search Algorithm‐Based Artificial Neural Network
The inputs of ANN include the room temperature , WH temperature , time of the system
and total power consumption of the system . The signals are output to ON/OFF the WH, AC,
WM, and REF. By using the ANN training and testing data, we can find all other parameters, such as
inputs, number of neurons in each hidden layer, number of hidden layers, weights, learning rate, and
output. LSA searches the best values for learning rate and the number of neurons in each hidden
layer to enhance the ANN performance. The objective function for 10, 20, 30, 40 and 50 population
sizes can be obtained, as shown in Figure 22. Several populations are executed to permit the LSA to
select the population size to achieve the minimum error and the consumption time.
0 5 10 15 20 25 30 35 40 45 50 55 60
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Time (minute)
PowerconsumptioninkW
0 5 10 15 20 25 30 35 40 45 50 55 60
0
0.05
0.1
0.15
0.17
Time (minute)
Powerconsumption(kW)
1
2
3
4
5
6
x 10
-7
Objectivefunction
LSA10
LSA20
LSA30
LSA40
LSA50
Figure 20. Actual power consumption curve of WM load.
Energies 2016, 9, 716 15 of 19
consumption levels during washing, rinsing, and spinning. In the washing cycle, three intervals at
11.5, 2.25 and 2.5 min were needed to finish the task. In the rinsing cycle, three duration times were
needed to finish the job, with a 1 min interval. Finally, the last cycle needed 2.5, 2.5 and 6min to
complete the job. The experimental measurement data of the WM power consumption are shown in
Figure 20. The power consumption curve of the REF was measured every minute, as shown in Figure 21.
Figure 20. Actual power consumption curve of WM load.
Figure 21. Actual power consumption curve of REF load.
6.3. Results of the Hybrid Lightning Search Algorithm‐Based Artificial Neural Network
The inputs of ANN include the room temperature , WH temperature , time of the system
and total power consumption of the system . The signals are output to ON/OFF the WH, AC,
WM, and REF. By using the ANN training and testing data, we can find all other parameters, such as
inputs, number of neurons in each hidden layer, number of hidden layers, weights, learning rate, and
output. LSA searches the best values for learning rate and the number of neurons in each hidden
layer to enhance the ANN performance. The objective function for 10, 20, 30, 40 and 50 population
sizes can be obtained, as shown in Figure 22. Several populations are executed to permit the LSA to
select the population size to achieve the minimum error and the consumption time.
0 5 10 15 20 25 30 35 40 45 50 55 60
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Time (minute)
PowerconsumptioninkW
0 5 10 15 20 25 30 35 40 45 50 55 60
0
0.05
0.1
0.15
0.17
Time (minute)
Powerconsumption(kW)
2
3
4
5
6
x 10
-7
Objectivefunction
LSA10
LSA20
LSA30
LSA40
LSA50
Figure 21. Actual power consumption curve of REF load.
6.3. Results of the Hybrid Lightning Search Algorithm-Based Artificial Neural Network
The inputs of ANN include the room temperature Tac, WH temperature Twh, time of the system
Tim and total power consumption of the system Tot. The signals are output to ON/OFF the WH, AC,
WM, and REF. By using the ANN training and testing data, we can find all other parameters, such as
inputs, number of neurons in each hidden layer, number of hidden layers, weights, learning rate, and
output. LSA searches the best values for learning rate and the number of neurons in each hidden layer
to enhance the ANN performance. The objective function for 10, 20, 30, 40 and 50 population sizes can
be obtained, as shown in Figure 22. Several populations are executed to permit the LSA to select the
population size to achieve the minimum error and the consumption time.
16. Energies 2016, 9, 716 16 of 20
WM, and REF. By using the ANN training and testing data, we can find all other parameters, such as
inputs, number of neurons in each hidden layer, number of hidden layers, weights, learning rate, and
output. LSA searches the best values for learning rate and the number of neurons in each hidden
layer to enhance the ANN performance. The objective function for 10, 20, 30, 40 and 50 population
sizes can be obtained, as shown in Figure 22. Several populations are executed to permit the LSA to
select the population size to achieve the minimum error and the consumption time.
Figure 22. Objective function with iteration of the hybrid LSA‐ANN for different population sizes.
Figure 22 illustrates that the number of populations (N) as 40 can give the best result for the LSA
than the population size numbers of 10, 20 and 30 because a high error and the objective function are
achieved in error 9.128 × 10−9 after 40 iterations. The population size of 50 needs more working time
than the population size of 40. The ANN parameters based on the results of the hybrid LSA‐ANN are
shown in Table 1. The PSO algorithm is also implemented to obtain the same objective for 10, 20, 30,
0 20 40 60 80 100
0
1
2
3
4
5
6
x 10
-7
Iterations
Objectivefunction
LSA10
LSA20
LSA30
LSA40
LSA50
Figure 22. Objective function with iteration of the hybrid LSA-ANN for different population sizes.
Figure 22 illustrates that the number of populations (N) as 40 can give the best result for the LSA
than the population size numbers of 10, 20 and 30 because a high error and the objective function are
achieved in error 9.128 × 10−9 after 40 iterations. The population size of 50 needs more working time
than the population size of 40. The ANN parameters based on the results of the hybrid LSA-ANN are
shown in Table 1. The PSO algorithm is also implemented to obtain the same objective for 10, 20, 30,
40 and 50 population sizes for comparison with the results from the hybrid LSA-ANN, as shown in
Figure 23.
Table 1. ANN-designed parameters.
Parameter Value Type
Number of inputs 5 ANN inputs
Number of outputs 4 ANN outputs
Number of hidden layers 2 ANN hidden layer
Number of neurons in hidden layer N1 6 Obtained from LSA
Number of neurons in hidden layer N2 4 Obtained from LSA
Number of iterations 1000 ANN iterations
Learning rate 0.6175 Obtained from LSA
Energies 2016, 9, 716 16 of 19
40 and 50 population sizes for comparison with the results from the hybrid LSA‐ANN, as shown in
Figure 23.
Table 1. ANN‐designed parameters.
Parameter Value Type
Number of inputs 5 ANN inputs
Number of outputs 4 ANN outputs
Number of hidden layers 2 ANN hidden layer
Number of neurons in hidden layer N1 6 Obtained from LSA
Number of neurons in hidden layer N2 4 Obtained from LSA
Number of iterations 1000 ANN iterations
Learning rate 0.6175 Obtained from LSA
Figure 23. Objective function with iteration of the hybrid particle swarm optimization (PSO)‐ANN
for different population sizes.
The obtained results from the hybrid LSA‐ANN are compared with those from the hybrid PSO‐
ANN to validate the developed algorithm. The result of the hybrid LSA‐ANN achieves a MAE error
of 9.128 × 10−9 after 40 iterations at a population size of 40. The hybrid PSO‐ANN obtains a MAE error
of 1.195 × 10−8 after 81 iterations at a population size of 40, as illustrated in Figure 24.
0 20 40 60 80 100
0
1
2
3
4
5
6
x 10
-7
Iterations
Objectivefunction
PSO10
PSO20
PSO30
PSO40
PSO50
0 20 40 60 80 100
0
1
2
3
4
5
x 10
-8
Iterations
Objectivefunction
PSO-ANN
LSA-ANN
Figure 23. Objective function with iteration of the hybrid particle swarm optimization (PSO)-ANN for
different population sizes.
The obtained results from the hybrid LSA-ANN are compared with those from the hybrid
PSO-ANN to validate the developed algorithm. The result of the hybrid LSA-ANN achieves a MAE
error of 9.128 × 10−9 after 40 iterations at a population size of 40. The hybrid PSO-ANN obtains a MAE
error of 1.195 × 10−8 after 81 iterations at a population size of 40, as illustrated in Figure 24.
17. Energies 2016, 9, 716 17 of 20
for different population sizes.
The obtained results from the hybrid LSA‐ANN are compared with those from the hybrid PSO‐
ANN to validate the developed algorithm. The result of the hybrid LSA‐ANN achieves a MAE error
of 9.128 × 10−9 after 40 iterations at a population size of 40. The hybrid PSO‐ANN obtains a MAE error
of 1.195 × 10−8 after 81 iterations at a population size of 40, as illustrated in Figure 24.
Figure 24. Performance comparison of LSA and PSO.
The regression coefficient (R) close to unity and the value of R for training is 1. The performance
of the hybrid LSA‐ANN is shown in Figure 25.
Figure 25. Performance of the hybrid LSA‐ANN.
0 20 40 60 80 100
0
1
2
3
4
5
x 10
-8
Iterations
Objectivefunction
PSO-ANN
LSA-ANN
0 0.2 0.4 0.6 0.8 1
0
0.2
0.4
0.6
0.8
1
Target
Output~=1*Target+8.5e-08
Training: R=1
Y = T
Fit
Data
Figure 24. Performance comparison of LSA and PSO.
The regression coefficient (R) close to unity and the value of R for training is 1. The performance
of the hybrid LSA-ANN is shown in Figure 25.
for different population sizes.
The obtained results from the hybrid LSA‐ANN are compared with those from the hybrid PSO‐
ANN to validate the developed algorithm. The result of the hybrid LSA‐ANN achieves a MAE error
of 9.128 × 10−9 after 40 iterations at a population size of 40. The hybrid PSO‐ANN obtains a MAE error
of 1.195 × 10−8 after 81 iterations at a population size of 40, as illustrated in Figure 24.
Figure 24. Performance comparison of LSA and PSO.
The regression coefficient (R) close to unity and the value of R for training is 1. The performance
of the hybrid LSA‐ANN is shown in Figure 25.
Figure 25. Performance of the hybrid LSA‐ANN.
0 20 40 60 80 100
0
1
2
3
4
5
x 10
-8
Iterations
Objectivefunction
PSO-ANN
LSA-ANN
0 0.2 0.4 0.6 0.8 1
0
0.2
0.4
0.6
0.8
1
Target
Output~=1*Target+8.5e-08
Training: R=1
Y = T
Fit
Data
Figure 25. Performance of the hybrid LSA-ANN.
6.4. Results of the Proposed Hybrid LSA-ANN Based Home Energy Management Scheduling Controller
A DR event is usually imposed by the power utility to reduce the total power consumption at the
peak period time with DL. The DR event is assumed to start from between 4:00 P.M. and 11:00 P.M.,
and DL is assumed to be 3 kW. If the total electrical power consumption is greater than the DL, then the
HEMSC will turn OFF the appliance according to priority, starting with REF, and force the loads to
shift and schedule their operating time after the DR event to keep the total power consumption below
its DL. The HEMS issues a control signal to turn ON the appliance when the total household load
is below its DL level. In this way, the HEMSC will optimize the scheduling of the appliances while
maintaining the total power consumption below its DL.
Two case studies are considered to describe the implementation of the HEMSC algorithm.
The first case does not apply the DR signal and the second case applies the DR signal by using
the hybrid LSA-ANN, as shown in Figure 26. The second case using the hybrid PSO-ANN is shown in
Figure 27 to clarify the performances of WH, AC, WM and REF, and to calculate the power saving.
Figures 26 and 27 show that AC, WM, and REF have to be switched OFF, and one appliance,
which is the WH, can be operated and draws 3 kW according to priority. The AC and REF require their
schedules to be shifted to another period. The results explain the performance of the proposed HEMSC
with the reduction of the total power consumption of the four home appliances at a specific time below
the DL value. The algorithm prevents the total power consumption from exceeding the selected DL
value. The energy saving for the total power consumption is 9.7138% per 7 h without any effect on
the comfort level of the end users, whereas the energy saving for the total power by using the hybrid
PSO-ANN is 2.3817% per 7 h. The power saving performance of the proposed hybrid LSA-ANN based
HEMSC is better than that of the hybrid PSO-ANN.
18. Energies 2016, 9, 716 18 of 20
load is below its DL level. In this way, the HEMSC will optimize the scheduling of the appliances
while maintaining the total power consumption below its DL.
Two case studies are considered to describe the implementation of the HEMSC algorithm. The
first case does not apply the DR signal and the second case applies the DR signal by using the hybrid
LSA‐ANN, as shown in Figure 26. The second case using the hybrid PSO‐ANN is shown in Figure 27
to clarify the performances of WH, AC, WM and REF, and to calculate the power saving.
Figure 26. Total power consumption before and after DR signal with the hybrid LSA‐ANN.
Figure 27. Total power consumption before and after DR signal with the hybrid PSO‐ANN.
Figures 26 and 27 show that AC, WM, and REF have to be switched OFF, and one appliance,
which is the WH, can be operated and draws 3 kW according to priority. The AC and REF require
their schedules to be shifted to another period. The results explain the performance of the proposed
HEMSC with the reduction of the total power consumption of the four home appliances at a specific
time below the DL value. The algorithm prevents the total power consumption from exceeding the
selected DL value. The energy saving for the total power consumption is 9.7138% per 7 h without any
effect on the comfort level of the end users, whereas the energy saving for the total power by using
the hybrid PSO‐ANN is 2.3817% per 7 h. The power saving performance of the proposed hybrid LSA‐
ANN based HEMSC is better than that of the hybrid PSO‐ANN.
7. Conclusions
This paper presents the application of LSA to solve the problems of ANN by finding the
optimum learning rate and the best value of neurons in each hidden layer of the neural network that
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
0
1
2
3
4
5
6
7
Time (hour)
Powerconsumption(kW)
Before DR signal After DR signal
Water
heater
Air conditioner
Refrigerator
Washing
machine
Demand limit
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
0
1
2
3
4
5
6
7
Time (hour)
Powerconsumption(kW)
Before DR signal After DR signal
Demand limit
Refrigerator Air conditioner
Water heater Washing
machine
Figure 26. Total power consumption before and after DR signal with the hybrid LSA-ANN.
load is below its DL level. In this way, the HEMSC will optimize the scheduling of the appliances
while maintaining the total power consumption below its DL.
Two case studies are considered to describe the implementation of the HEMSC algorithm. The
first case does not apply the DR signal and the second case applies the DR signal by using the hybrid
LSA‐ANN, as shown in Figure 26. The second case using the hybrid PSO‐ANN is shown in Figure 27
to clarify the performances of WH, AC, WM and REF, and to calculate the power saving.
Figure 26. Total power consumption before and after DR signal with the hybrid LSA‐ANN.
Figure 27. Total power consumption before and after DR signal with the hybrid PSO‐ANN.
Figures 26 and 27 show that AC, WM, and REF have to be switched OFF, and one appliance,
which is the WH, can be operated and draws 3 kW according to priority. The AC and REF require
their schedules to be shifted to another period. The results explain the performance of the proposed
HEMSC with the reduction of the total power consumption of the four home appliances at a specific
time below the DL value. The algorithm prevents the total power consumption from exceeding the
selected DL value. The energy saving for the total power consumption is 9.7138% per 7 h without any
effect on the comfort level of the end users, whereas the energy saving for the total power by using
the hybrid PSO‐ANN is 2.3817% per 7 h. The power saving performance of the proposed hybrid LSA‐
ANN based HEMSC is better than that of the hybrid PSO‐ANN.
7. Conclusions
This paper presents the application of LSA to solve the problems of ANN by finding the
optimum learning rate and the best value of neurons in each hidden layer of the neural network that
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
0
1
2
3
4
5
6
7
Time (hour)
Powerconsumption(kW)
Before DR signal After DR signal
Water
heater
Air conditioner
Refrigerator
Washing
machine
Demand limit
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
0
1
2
3
4
5
6
7
Time (hour)
Powerconsumption(kW)
Before DR signal After DR signal
Demand limit
Refrigerator Air conditioner
Water heater Washing
machine
Figure 27. Total power consumption before and after DR signal with the hybrid PSO-ANN.
7. Conclusions
This paper presents the application of LSA to solve the problems of ANN by finding the optimum
learning rate and the best value of neurons in each hidden layer of the neural network that can be
used in HEMSC. A comparison of results shows that the hybrid LSA-ANN used in HEMSC is better
than the hybrid PSO-ANN in terms of scheduling household appliances and reducing the peak load
while guaranteeing end user comfort associated with the operation of loads. The ANN ON/OFF
estimation status is enhanced by minimizing the MAE. The hybrid LSA-ANN achieves a MAE error
of 9.128 × 10−9, whereas the hybrid PSO-ANN achieves a MAE error of 1.195 × 10−8. The proposed
algorithm shows a better response in switching the status in HEMSC. Therefore, the energy saving
for the total power by using the hybrid LSA-ANN is 9.7138% per 7 h, whereas that by using the
hybrid PSO-ANN is 2.3817% per 7 h. The results explain the capability of the proposed HEMSC
algorithm to maintain the total electrical energy consumption below the DL value during a DR event.
Moreover, the algorithm easily deals with the DR signals and is more effective in energy saving.
Acknowledgments: The authors gratefully acknowledge the University Kebangsaan Malaysia for the financial
support for the project under research Grant No. DIP-2014-028.
Author Contributions: Maytham S. Ahmed is a Ph.D. student implementing the project and he is the
corresponding author of the manuscript. Azah Mohamed is the main supervisor of the student who leads
the project and edits the manuscript. Hussain Shareef is the co-supervisor of the student who has edited the
manuscript and given valuable suggestions to improve the manuscript. Raad Z. Homod is the co-supervisor of
the student who has edited the manuscript.
Conflicts of Interest: The authors declare no conflict of interest.
19. Energies 2016, 9, 716 19 of 20
References
1. Deploying a Smarter Grid through Cable Solutions and Services, 2010. Available online: http://www.
nexans.com/Corporate/2010/WHITE_PAPER_SMART_GRIDS_2010.pdf (accessed on 9 August 2016).
2. Hammond, G.P.; Pearson, P.J. Challenges of the transition to a low carbon, more electric future: From here to
2050. Energy Policy 2013, 52, 1–9. [CrossRef]
3. Barton, J.; Huang, S.; Infield, D.; Leach, M.; Ogunkunle, D.; Torriti, J.; Thomson, M. The evolution of
electricity demand and the role for demand side participation, in buildings and transport. Energy Policy 2013,
52, 85–102. [CrossRef]
4. Huaman, R.N.E.; Tian, X.J. Energy related CO2 emissions and the progress on ccs projects: A review.
Renew. Sustain. Energy Rev. 2014, 31, 368–385. [CrossRef]
5. Yun, G.Y.; Kim, H.; Kim, J.T. Effects of occupancy and lighting use patterns on lighting energy consumption.
Energy Build. 2012, 46, 152–158. [CrossRef]
6. Richardson, I.; Thomson, M.; Infield, D.; Clifford, C. Domestic electricity use: A high-resolution energy
demand model. Energy Build. 2010, 42, 1878–1887. [CrossRef]
7. Horst, G.R.; Zhang, J.; Syvokozov, A.D. Total home Energy Management System. U.S. Patent 7561977 B2,
14 July 2009.
8. Arif, M.T.; Oo, A.M.T.; Stojcevski, A. An investigation for improved home energy management.
In Proceedings of the 2014 Australasian Universities Power Engineering Conference (AUPEC), Perth,
Australia, 28 September–1 October 2014.
9. Vardakas, J.S.; Zorba, N.; Verikoukis, C.V. A survey on demand response programs in smart grids:
Pricing methods and optimization algorithms. IEEE Commun. Surv. Tutor. 2015, 17, 152–178. [CrossRef]
10. Patel, K.; Khosla, A. Home energy management systems in future smart grid networks: A systematic
review. In Proceedings of the 2015 1st International Conference on Next Generation Computing Technologies
(NGCT), Dehradun, India, 4–5 September 2015; pp. 479–483.
11. Farzamkia, S.; Ranjbar, H.; Hatami, A.; Iman-Eini, H. A novel PSO (particle swarm optimization)-based
approach for optimal schedule of refrigerators using experimental models. Energy 2016, 107, 707–715.
[CrossRef]
12. Abd Ali, J.; Hannan, M.A.; Mohamed, A. A novel quantum-behaved lightning search algorithm approach
to improve the fuzzy logic speed controller for an induction motor drive. Energies 2015, 8, 13112–13136.
[CrossRef]
13. Ali, J.A.; Hannan, M.; Mohamed, A.; Abdolrasol, M.G. Fuzzy logic speed controller optimization approach
for induction motor drive using backtracking search algorithm. Measurement 2016, 78, 49–62. [CrossRef]
14. Ibrahim, A.A.; Mohamed, A.; Shareef, H. Optimal power quality monitor placement in power systems using
an adaptive quantum-inspired binary gravitational search algorithm. Int. J. Electr. Power Energy Syst. 2014,
57, 404–413. [CrossRef]
15. Kang, S.J.; Park, J.; Oh, K.-Y.; Noh, J.G.; Park, H. Scheduling-based real time energy flow control strategy for
building energy management system. Energy Build. 2014, 75, 239–248. [CrossRef]
16. Mohsenian-Rad, A.H.; Leon-Garcia, A. Optimal residential load control with price prediction in real-time
electricity pricing environments. IEEE Trans. Smart Grid 2010, 1, 120–133. [CrossRef]
17. Haider, H.T.; See, O.H.; Elmenreich, W. Dynamic residential load scheduling based on adaptive consumption
level pricing scheme. Electr. Power Syst. Res. 2016, 133, 27–35. [CrossRef]
18. Hernandez, C.A.; Romero, R.; Giral, D. Optimization of the use of residential lighting with neural network.
In Proceedings of the 2010 International Conference on Computational Intelligence and Software Engineering
(CiSE), Wuhan, China, 10–12 December 2010.
19. Pedrasa, M.A.; Spooner, E.D.; MacGill, I.F. Robust scheduling of residential distributed energy resources
using a novel energy service decision-support tool. In Proceedings of the 2011 IEEE PES Innovative Smart
Grid Technologies (ISGT), Anaheim, CA, USA, 17–19 January 2011.
20. Setlhaolo, D.; Xia, X.; Zhang, J. Optimal scheduling of household appliances for demand response.
Electr. Power Syst. Res. 2014, 116, 24–28. [CrossRef]
21. Wang, Z.; Yang, R.; Wang, L. Multi-agent control system with intelligent optimization for smart and
energy-efficient buildings. In Proceedings of the IECON 2010—36th Annual Conference on IEEE Industrial
Electronics Society, Glendale, AZ, USA, 7–10 November 2010; pp. 1144–1149.