3. THE COMPANY
HT LABOR + HOSPITALTECHNIK AG
Our projecting experience of almost 50 years in design an construction of laboratory and hospital projects and constant
transfer of expertise create the base for the successful execution of most diverse construction projects and their
space requirements.
Hospitaltechnik GmbH
1963
OPITZ + FLIERL
HOSPITALTECHNIK GMBH
1987
OPITZ + FLIERL
HOSPITALTECHNIK AG
1997
HT LABOR +
HOSPITALTECHNIK AG
2010
NEUE WEGE
NEW PATHS
4. PRODUCTION FACILITIES
Laser
Bending press
FULLY AUTOMATED PRODUCTION CENTER
Punching-Cutting
Storage system
Robotic palletiser
Bending press
Bending cell
In our processing centre, we produce components from
single lots to large batch sizes at the highest quality:
Automated steel sheet storage system and automatic
loading- and unloading equipment for
- laser machine
- punching machine
- bending cell
- bending presses
Consequently, we combine the most up-to-date grade of
automation with the experience and the quality
consciousness of our staff.
Lasering
Bending
Adhesive technology
Welding
Fitting
Packing
Shipping
6. COMPETENCE
HT LABOR + HOSPITALTECHNIK AG
cooperates interdisciplinary with architects, engineers and customers.
Comprehensively we support the entire field from the determination of the basic values via the outline- and execution
planning as well as the cost planning and tender procedure up to the project supervision and documentation.
We offer a construction-kit for functional and extensively equipped areas with demand on high quality regarding
surface and function.
LABORATORY
HOSPITAL
7. GREEN MINDED DESIGN
Materials:
Stainless steel, Glass, Impact
HT LABOR + HOSPITALTECHNIK AG
is using pure materials instead of
critical mixtures. In case of fire, there
will be no development of toxic gases.
Production:
Thanks to product purity, all overcuts can
be returned into the material cycle without
additional effort.
Utilization:
By application of pure materials, we also
protect our customers and staff for
emissions.
The surfaces have an proven
antimicrobicidal effect.
Recycling:
All used materials are recyclable and thus
can be disposed simply and environmental
friendly even after decades of use.
9. OPERATING THEATRE
INTRACARDIAC CATHEDER/
ANGIOGRAPHY
Endoscopic surgery of the heart by catheter
and/or diagnostic Body-imaging systems
with contrast agents require special
Shielding against
- x-rays
- electro-magnetic fields
The shielding is integrated in the wall
system and considers all ducts for media
systems.
10. OPERATING THEATRE
MEDICAL COMPETENCE
CENTER
Areas
-Reconstructive plastic surgery
-Microsurgery
- Radiologie
Design
- Glass wall with flush integration of
imaging-, electric- and media systems
-Shielding against x-rays integrated
in the wall system
- Integrated wall heating system
11. OPERATING THEATRE
RECONSTRUCTION OT AREA
Areas
- 3 OR´s
- Preparation rooms
- Corridor area with scrubs
- Furniture
Design
- Full-high glass-system
- The rebuilding was realised within
three months during ongoing operation
handling
12. INTENSIVE CARE UNIT
INTENSIVE CARE UNIT WITH
CENTRALISED PATIENT
CONTROL
Design
- High transparency by use of full
high glass walls to the corridors
- Full glass door
- Partition walls made of Impact wall
system
13. INTENSIVE CARE UNIT
INTENSIVE CARE UNIT
Area
- 2 Operating rooms
- 12 ICU
- Corridors
- Reception area
Design
- Wall and integrated furniture in
Impact material
- Pass-through cabinets to the OT
- Impact partition walls
- Doors in satined glass
+ inspection element
- Reception area with counter
14. INTENSIVE CARE UNIT
INTENSIVE CARE UNIT WITH
GLASS WALL SYSTEM
Area
- ICU
Design
- Full high glass walls with sliding doors
- Integrated venetian blinds in walls and doors
- Partition walls made of Impact wall system
15. CORRIDOR
CORRIDOR GLASS WALL SYSTEM
Area
- Patients corridor
- Clean corridor
- Changing rooms
Design
Corridor walls with continuous glass front
made of coated glass
- Full high sliding doors
- Integrated cabinet system
16. CORRIDOR
IMPACT WALL WITH
GLASS SYSTEM
Area
- Lobby area
- Corridor
- Store units
with Impact- and glass-wall-systems
Design
- Full glass front
- Variable glass partition walls
17. CORRIDOR
PRINTED IMPACT WALL SYSTEMS
Area
- Walls
- Doors
- Ceiling
- Counter
Design
Printed impact panels made from
- Graphics
- Photos
- Images from photo agencies
Various design in combination with uni-tones
and materials like glass and mineral composite
18. MODULAR FURNITURE
MODULAR FURNITURE
Area
- Intervention
- OT-preperation
Design
Intergrated
- Sink
- Refrigerator
- Microwave
- Workplate made of mineral fibre or
stainless steel
- ISO-modules
- Warming box
19. DOORS
DOOR SYSTEMS - VARIANTS
Sliding doors
- 1-wing sliding door
- 2-wing sliding door
- Telescopic sliding door
Hinged doors
- 1-wing sliding door
- 2-wing sliding door
Requirements
- Fire protection doors EI 30 to EI 90
- Noise protection doors 39 R`w
- Hermetic sliding doors
- X-ray protection doos
Surface qualities
- Stainless steel grounded or coated
- Steel coated
- Laminated surface
- Glass
20. STERILISATION
STERILISATION AREA IN HOSPITAL
Comprehensive room system with
coordination of all technical components
and sterilisation systems
Design
- Stainless steel walls and ceilings
- Door systems
- Air ventilation system
- Build-in cabinets
- ISO-modules
- Warming box
21. HIGH SAFETY LAB
HIGH SAFETY LABORATORY
WITH SAFETY LEVEL BSL 4
AS COMLETE CONTAINMENT
Area
- Lab for virological analysis
Design
- Personnel access by disinfecting sluice
- Material access by immersion sluice
- Gastight wall system made of stainless
steel
- Gastight conduct of all media systems
- Gastight door systems and glazing
- Control systems
22. RESEARCH LAB
STEM CELL LABS - GMP AREA
Area
- Laboratory complex for stem cell research
- Technical corridors
- Access corridor with sluice system
Design
- Wall system stainless steel
- Sluice systems with air shower
- Working area with circulation air flow ceiling
- Fixed installed gassing system
- Mobile gassing system
- Sensor system for particle rating,
humidity and pressure control
- Air ducts with valve and control unit for HVAC
23. ANIMAL TESTROOMS
BSL 3 RESEARCH COMPLEX WITH
ANIMAL LAB
Area
- Animal stock
- Access Corridor
- Laboratory Area
Design
- Full-high walls made of stainless steel BSL 3
- Gastight doors with light filters
- Gastight connections for pipes and channels
- Fender in the animal stock area
24. STRUCTURAL
REQUIREMENTS
X-ray protection
Natural lead equivalent value
• single wall 0,3 mm Pb
• double wall 0,6 mm Pb
Higher x-ray protection rates up to max. requirements of 50,00 mm Pb for walls, doors and windows
are possible by means of lead shielding.
Electro-magnetic shielding
High-frequency electromagnetic waves generate electromagnetic radiation up to 9 Tesla.
It disturbes all surrounding electronic equipment and must be dissipated by a complete closed
shielding. All air conditioning-, electric- and gas-channels are fitted with filter systems.
Noise Protection
Noise protection rate according to test certificate
• wall – ceiling
without mineral fibre >R´w 44 dB
with mineral fibre
>R´w 56 dB
• sliding door
>Rw,P 43 dB
25. STRUCTURAL
REQUIREMENTS
Fire protection
Test certificates are available for
• double wall F90 A / EI 90 A
• single wall F30 A / EI 30
• windows EI 90
• sliging doors T30 / EI 30
• gastight doors EI 30
Hygiene
Test certificates are available for
• tested room systems, all conncetions to ceiling, flooring, doors and corners are hygienic solved and
envidenced with test certificate
Tightness
Test certificates are available for
•
•
•
•
•
•
gastight wall systems for rooms BSL 2,3,4
gastight hinged door systems
sluice systems
material sluices
personnel sluices
GMP areas
26. HYGIENE
Surface characters
Testing of the susceptibility to germination, cleaning possibilities, antimicrobial effect and microbial resistiveness
has documented, that our materials meet with the most demanding hygienic requirements.
• Bacteria, viruses and fungi will be reduced just by the material properties
• The plain, closed surfaces avoid the penetration of pathogenic agents and thus avoid development of bio film
• The materials are resistant against transformation by microorganisms
Cleaning and Disinfection
All materials are tested and certified for application in clean rooms.
• Resistant against detergents and germicides according to VAH-list
• Resistant against gassing with H2O2 and Formaldehyde
• Hand disinfection and washing facilities
Hygiene-Zertificate
• Certified room systems, all connections to ceilings, flooring, doors and corners are designed to meet
the highest hygiene standards and supported by hygiene certificates.
INFEKTIONSKONTROLLE
27. KOMPETENZ
PROJECT COMPETENCE
The team HT LABOR + HOSPITALTECHNIK AG provides services in the areas of layout planning, civil engineering and technical
equipment and provides the customer with comprehensive project management know-how. With this structure, HT offers to the builder and the
client packages from single rooms to multidisciplinary integrated solutions from one supplier. We consider ourselves as problem solvers for critical
areas in laboratory and hospital construction.
QUALIFICATION
QUALIFICATION
ENGINEERING + PLANNING
PROJECT HANDLING +
PRODUCT PORTFOLIO
INFECTION CONTROL
HYGIENE TEST + SERVICE
28. PROJECT MANAGEMENT
The HT LABOR + HOSPITALTECHNIK AG
is working worldwide for a large number of companies, institutions and public authorities. Numerous follow-up orders prove our clients appreciation
and the trust into the HT-team. Worldwide we could successfully realize already more than 5000 projects in the business fields of laboratory and
hospital. Therefore, our customers benefit from extensive process reliability concerning projects and products.
PROJECT MANAGEMENT
PROJECT MANAGEMENT
31. 3D PROJECT PLANNING
3D- project planning
Well-thought-out to the detail
By our highly developed planning software, we enable you in the forefront of
the project:
- Room lighting calculation
- Depiction of laminar flow
- Flow characteristics
- Considerations of logistics
For you as our customer this provides
enormous safety already during the
planning phase.
32. 3D PROJECT PLANNING
3D-project planning
By our complex 3D-drawings, you can
demonstrate and avoid collision risks in
densely equipped rooms. An optimised display of glide paths and cruising radiuses of
- Scanners
- Ceiling supply units
- Operating lights
- Cameras- and navigation systems
- Door installations
- Monitors
- Functional furniture
will be guaranteed.
71. WALL HEATING SYSTEM
BEHIND THE WALL PANEL
Wall panels with low-temperature heating integrated in the wall element
Higher efficiency with 160 Watt / m²
Also cooling option possible!
Infrared camera – Temperatur test
73. DIN 1946-4 / CLASS Ia
Requirements
3-stage air filtration (F7, F9, H13 Filter)
Total supply air > total exhaust air
Supply air temperature 19 °C to 26 °C, adjustable exhaust air temperature
not less than supply air temperature external air rate 1200 m3/h
False ceilings to ensure negative pressure
Overflow of part of the supply air flow shall be directed through the doors to
anterrooms
Sound pressure level of system ≤ 48 dB(A),
Reduced air flow during non-operation hours
79. CLEAN ROOM ILLUMINATOR
Glass design, no frame, flush with the ceiling
Illuminator covering made of „silicate-glas“
Digital or analog control possible
LED-model with colour changer
OR clean room illuminator
3 x 80 Watt T16
2 x 80 Watt T16
3 x 54 Watt T16
2 x 54 Watt T16
Corridor or anterroom clean room
illuminator
1 x 28 Watt T16
129. PRODUCT PORTFOLIO
Wall systems
- Static sub-structure single panelled, in front of a wall
- Static sub-structure double panelled, as a dividing wall
- Static crossbeams for all installations
- Wall systems with noise-/fire-/x-ray protection
- Wall systems for laboratories with safety level BSL3/BSL4
- Wall covering metal
- Wall covering glass
- Wall covering impact
Installation modules
- Electric control panel
- Monitors
- Sensors and sensor panel
- OT clocks
- Glazing
- Pass-through cabinets
- Wall heating
- Gastight media channel
- Exhaust air cabinets
Ventilation
Ceiling
- Laminar flow ceiling / Air circulation ceiling
- Air handling units
- Air-conditioning channels and control
- Gassing system
- Ceiling panels for laboratories up to safety level
BSL3/BSL4
- Cean room illuminators
Gastight sluices
Personnel sluices
- Wet shower
- Dry air shower
Material sluice
- Immersion sluice
- Path-through sluice
- Material and gassing sluice
Doors
- Hinged doors
- Sliding doors
- Fire protection doors
- Hermetic doors
- Noise protection doors
- Gastight door systems
Scrub facilities
Furniture Systems
- Scrubs made of mineral composite
- Scrub facilities stainless steel
- Combination taps with arm operated lever or optoelectronics
- Soap/germicide Dispenser
- Mirrors
- Metal
- Stainless steel
- Laminate
- Impact
163. SERVICE
For protection and preservation of highest hygiene standards, we provide in addition to the construction activities the following service.
Hygiene test
Technical hygiene acceptance test of VAC-facilities according to
DIN 1946-4 or applicable country norm
• Particle rating below the laminar flow ceiling
• Verification of protective effect in aseptic safety areas compared
to the surrounding area
• Evaluation of the protective effect considering airflow obstructing
bodies and cooling loads
Safety test
We offer annual maintenance for all electrical components as
well as door systems and integrated components.
• Door drive systems
• Room illumination
• Filter test
• Mobile components
164. SERVICE
For protection and preservation of highest hygiene standards, we provide in addition to the construction activities the following service.
Leak-tightness test / pressure test
Leak-tightness of room systems to certificate the pressure
maintenance in tested rooms
• Tightness according to the required pressure range, but max.
worst-case gas-tightness up to pressure of +/- 500 Pa (1000 Pa)
for all components
• Test of temperature and humidity
• Replaceable flange plates with integrated duct intake for test
procedures
• Graphical reports
Decontamination
H2O2-gassing for decontamination of surfaces contaminated by
germs, fungi, viruses or spores
• Integrated gas spreading system
• Optional fixed installed gas resistant unit in the wall system or
gassing by duct intake from outside
165. ADVANTAGES
CONSTRUCTION PHASE
Integrated and flexible construction-kit
Innovative detail solutions for all installations
Certificates for hygiene, fire-, noise- and x-ray protection
Clearly calculated amount of investment
High planning reliability before start of installation
Short and reasonable installation
FUTURE
Open for integration of new systems
Easy maintenance
Recyclable building materials
166. COMPETENCE
HT LABOR + HOSPITALTECHNIK AG
cooperates interdisciplinary with architects, engineers and customers.
Comprehensively we support the entire field from the determination of the basic values via the outline- and execution
planning as well as the cost planning and tender procedure up to the project supervision and documentation.
We offer a construction-kit for functional and extensively equipped areas with demand on high quality regarding
surface and function.
LABORATORY
HOSPITAL
QUALIFICATION
ENGINEERING + PLANNING
PROJECT HANDLING +
PRODUCT PORTFOLIO
INFECTION CONTROL
HYGIENE TEST + SERVICE
167. DEATH TOLL
ANNUAL
357.000 – WAR
5.400.000 – DRUGS
9.000.000 – HUNGER
1.200.000 TRAFFIC
14.500.000 – INFECTION
168. SALES / DISTRIBUTION
GERMANY
Andreas Sternitzke
Sales Manager Germany/Austria
e-mail: andreas.sternitzke@ht-ag.de
Klaus Link
Product manager doors / furniture
e-mail: klaus.link@ht-ag.de
Simone Rauch - Sales Support
e-mail: simone.rauch@ht-ag.de
INTERNATIONAL
Jens Kühnlein - Export Sales Manager
e-mail: jens.kuehnlein@ht-ag.de
REGIONAL REPRESENTATIONS
Franco Mendieta - Export Sales Manager
e-mail: franco.mendieta@ht-ag.de
- CHINA
- FRANCE
Gerhard Scholz - Export Sales Manager
e-mail: gerhard.scholz@ht-ag.de
Julia Kratzer - Sales Support
e-mail: julia.kratzer@ht-ag.de
- INDIA
- ITALY
- POLAND
Birgit Pechler
Marketing / Sales Support
e-mail: birgit.pechler@of-ag.de
Managing Board
Thomas Fritsch
Vorstand, COO
Eva Gigla - Sales Support
e-mail; eva.gigla@ht-ag.de
- RUSSIA
- USA
Yvonne Brühmann
Managment Assistant
e-mail: yvonne.bruehmann@ht-ag.de
169. SALES / DISTRIBUTION
INTERNATIONAL
REGIONAL REPRESENTATIONS
- CHINA
- FRANCE
CHINA
POLAND
Kathy Feng - Regional Manager
e-mail: kathy.Feng@ht-ag.de
Andrew Szdlowski - Regional Manager
e-mail: Andrezey.Szdlowski@ht-ag.de
FRANCE
RUSSIA
- INDIA
Dany Foell- Regional Manager
e-mail: Dany.Foell@ht-ag.de
- ITALY
INDIA
- POLAND
Amit Sharma – Regional Manager
e-Mail: Amit.Sharma@ht-ag.de
- RUSSIA
ITALY
- USA
Thomas Chatzikamayannis –Regional Manager
e-Mail: Thomas.Chatzikamayannis@ht-ag.de
Managing Board
Thomas Fritsch
Vorstand, COO
Yvonne Brühmann
Managment Assistant
e-mail: yvonne.bruehmann@ht-ag.de
Veronika Khusainova - Regional Manager
e-mail: Veronika.Khusainova@ht-ag.de
USA
Luke Welker - Regional Manager
e-mail: Luke.Welker@ht-ag.de