Enviro Technology Services plc




Air Quality
Monitoring


ET digital Air Quality Systems and Networks are
the most advanced and flexible systems available.
Utilising Integrated Digital Technology (IDT),
data retrieval is redefined and the standard for
air quality monitoring systems reset.
                                                                                                   Open-path AQM System




Designed with the user in mind, ET’s systems are compact, simple to operate,
easy to maintain and are guaranteed "future-proof".
A wide range of continuous gas, particulate and meteorological sensors is available
and both analysers and sensors can be used together as an integrated system or
as stand-alone units. Adding a new analyser is simple – just plug in to the digital
RS232 switch and make a quick change in the EnviMan software.

• Internationally approved analysers - US EPA, MCERTS, TÜV, TA Luft, CE, CEN
• Gas analysers available for SO , NO, NO , NO , CO, O , VOCs, Benzene, 1,3 Butadiene,
                                 2           2    X      3

  H2S, N2O, NH3 and others

• Dust analysers and samplers for PM10, PM2.5, TSP, heavy metals, nitrates/sulphates.
• Meteorological sensors for wind speed, wind direction, temperature, relative humidity,   MCERTS Approved Gas Analysers
  pressure, precipitation, solar radiation, etc

• Analyser integration using Integrated Digital Technology (IDT) –                                  NEW
  internal datalogging, digital data transfer and remote system operation
                                                                                              Data collection
• Flexible calibration options using traceable and certified calibration sources                 capability
• Communication using modem, GSM, GPRS, satellite and ethernet/broadband.                      via internet/
                                                                                                broadband
www.et.co.uk
Air Quality Monitoring


                    Open-path Monitoring                                      Point Source Monitoring

                                   Enviro Technology specialises in           Enviro Technology has been a leader in the design
                                   open-path, air quality monitoring          and manufacture of air quality monitoring systems
                                   systems based on Differential Optical      since it was formed in 1983 and its analysers are to
                                   Absorption Spectroscopy (DOAS).            be found throughout the world in thousands of
                                  DOAS systems are fully automatic,           monitoring applications.

Open-path                         extremely flexible and, due to a            The latest generation of analysers bring improved
Monitoring System
                    minimum of human intervention, cost-effective to          performance, less drift and less temperature
                    run. Every minute, several thousand cubic metres          coefficient as a result of the use of advanced
                    of air interact with a beam of light between a            electronic, surface-mounted components and
                    light-source and a receiver to provide a more             improved control algorithms. The number of
                    representative sample than can obtained with              printed circuit boards has been halved and all cards
                    point sampling techniques.                                are interchangeable between machines leading to
                    One ET system will operate several light-paths            easier and quicker card replacement. An extensive
                    continuously measuring multiple gases over paths of       internal Data Acquisition System, utilising the
                    up to 1 km long. Any gas specified in the system’s        analysers’ internal records, is capable of logging
                    software can be measured, providing a facility to         multiple parameters to a total of 1 million records.
                    meet specific needs in a wide variety of applications.    ET gas analysers are MCERTS and US EPA
                    ET systems are MCERTS, TÜV and US EPA                     approved.
                    approved.                                                 100 UV Fluorescent Series
                                                                              Combines the proven UV fluorescent principle
                    ET System 300 Multi-gas System                            with state-of-the-art microprocessor technology to
                    This high performance package is designed for             provide accurate and dependable measurements of
                    urban, trend, fence-line, street canyon and model         SO2, H2S, TRS, and sulphur compounds.
                    validation applications. The system is available in
                    three configurations – Basic (SO2, NO2 and O3),           200 Chemiluminescent Series
                    BTX (benzene, toluene and xylene) and Basic/BTX           Provides the sensitivity, stability and ease of use
                    (combining all compounds).                                needed for ambient or continuous dilution
                                                                              monitoring of NO-NO2-NOX, NH3 and O3.

                                                                              300 IR Absorption Series
                                                                              Measures low ranges of CO, CO2 and N2O by
                                                                              comparing infrared energy absorbed by a sample
                                                                              to that absorbed by a reference gas according to
                                                                              Beer-Lambert law.

                                                                              400 UV Absorption Series
                                                                              Microprocessor-based with simple, multi-tasking,
                                                                              menu-driven software, for single pass, single path
                                                                              measurements of O3.

                                                                              700 Mass Flow Calibrator Series
                                                                              Combines highly accurate mass flow controllers
                                                                              and compressed sources of standard gases to
                                                                              provide calibration gases for multi-point span and
                                                                              zero checks.




                                                                             ET monitoring system using
                                                                             point source analysers
Mercury Monitoring                                   VOC/HC Monitoring

Continuous Ultra-Trace                               GC955 POPC/VOC/BTX Analyser
Mercury Analyser                                     Measures ozone precursors in ambient air. Two
Continuous, simple and unattended operation          separate sample and column systems are used to
providing precision analysis of total gaseous        measure C2-C5 and C6-C10 fractions. Methane
mercury in ambient air with an update rate as low    and non-methane compounds are measured
as 2.5 minutes and a detection limit of <0.1 ng/m3   separately without relying on the efficiency of a
(12 parts per quadrillion by volume).                catalytic converter.
                                                                                                             Continuous VOCHC analyser




  Continuous mercury analyser




 Services                                            Meteorological
 To complement the ET portfolio, EnviroService
 include flexible, quality-assured, service and
                                                     Instrumentation
 maintenance contracts managed by highly             A full range of instrumentation and systems from
 qualified and strategically located technicians     leading manufacturers including solid state wind sensors,
 and engineers.                                      barometric pressure sensors, precipitation gauges,
 The EnviroHire facility carries the largest         air temperature sensors, solar sensors and AutoMet™ -
 stock of environmental monitoring equipment         a complete, digital meteorological monitoring system
 in the UK or Europe offering a range of             that provides instant access to weather information.
 instruments and systems that will cover almost
 any short- or long-term project.
                                                     Air Quality Software
                                                     • Automatic
                                                        data collection

                                                     • Statistical
                                                        analysis

                                                     • Airquality
                                                        forecasting

                                                     • Dispersion
                                                        modelling

                                                     • Internet
                                                        public display
Air Quality Monitoring


Integrated Digital Technology
Integrated Digital Technology completely removes the need to
                                                                       Key features and
use expensive, low technology, analogue dataloggers. Data is           user benefits
transmitted via telephone modem, GSM unit (cellular telephone
network), Internet or to a dedicated site PC as required.              • Simple, inexpensive analyser
                                                                         integration using Integrated
As each analyser is able to store up to 5 years data/diagnostic           Digital Technology

information in internal memory and, by fully utilising the RS232       • Fully exploits analysers’fast,
                                                                         RS232 capabilities i.e.
                                                                                                   powerful
capabilities, many benefits can accrue to the user including:
                                                                          bi-directional communication

•   Full remote control of system via modem/GSM unit or                   digital data transfer

    Internet allowing health checks and calibration routines           • Full remoteGSM unit allowingvia
                                                                         modem or
                                                                                    control of system
    from the office
                                                                          remote calibration checks, etc
•   Data collection of user defined averages plus span,
                                                                       • Flexible and expandable systems
    zero and diagnostic data
                                                                       • Compatible with EnviMan software
• Remote control and calibration activation of individual              • Internationally approved analysers
    analyser set-up (i.e. time, range, etc).

• Span/zero data collection and graphing                               • Flexible calibrationzero and span
                                                                         including internal
                                                                                              options

                                                                          (IZS)
• Fast, remote troubleshooting by ET Technical
    Support Engineers.                                                 • Up most years parts warranty
                                                                         on
                                                                            to 5
                                                                                 analysers
Flexible calibration options                                           • Choice of ET service contracts
Unlike some suppliers, we can offer a choice of automatic or
manual calibration systems to meet a client’s exact requirements.
                                                                       • Simple operation and maintenance.
                                                                         Low running costs
Choose from a range of systems including permeation tubes,
certified gas cylinders and dynamic dilution calibrators.
                                                                       • EnviroHire equipment rental
                                                                         facilities available




                                                                                                     SM 200 combined dust
                                                                                                     monitor/sampler




    Monitoring
     for Life
                              EnviroTechnology Services plc
                              Advanced Environmental Systems - Sales, Hire and Services
                              Kingfisher Business Park, London Road, Stroud, Gloucestershire, GL5 2BY
                              Tel: +44 (0)1453 733200 Fax: +44 (0)1453 733201 Email: info@et.co.uk

     www.et.co.uk

Et aqm leaflet

  • 1.
    Enviro Technology Servicesplc Air Quality Monitoring ET digital Air Quality Systems and Networks are the most advanced and flexible systems available. Utilising Integrated Digital Technology (IDT), data retrieval is redefined and the standard for air quality monitoring systems reset. Open-path AQM System Designed with the user in mind, ET’s systems are compact, simple to operate, easy to maintain and are guaranteed "future-proof". A wide range of continuous gas, particulate and meteorological sensors is available and both analysers and sensors can be used together as an integrated system or as stand-alone units. Adding a new analyser is simple – just plug in to the digital RS232 switch and make a quick change in the EnviMan software. • Internationally approved analysers - US EPA, MCERTS, TÜV, TA Luft, CE, CEN • Gas analysers available for SO , NO, NO , NO , CO, O , VOCs, Benzene, 1,3 Butadiene, 2 2 X 3 H2S, N2O, NH3 and others • Dust analysers and samplers for PM10, PM2.5, TSP, heavy metals, nitrates/sulphates. • Meteorological sensors for wind speed, wind direction, temperature, relative humidity, MCERTS Approved Gas Analysers pressure, precipitation, solar radiation, etc • Analyser integration using Integrated Digital Technology (IDT) – NEW internal datalogging, digital data transfer and remote system operation Data collection • Flexible calibration options using traceable and certified calibration sources capability • Communication using modem, GSM, GPRS, satellite and ethernet/broadband. via internet/ broadband www.et.co.uk
  • 2.
    Air Quality Monitoring Open-path Monitoring Point Source Monitoring Enviro Technology specialises in Enviro Technology has been a leader in the design open-path, air quality monitoring and manufacture of air quality monitoring systems systems based on Differential Optical since it was formed in 1983 and its analysers are to Absorption Spectroscopy (DOAS). be found throughout the world in thousands of DOAS systems are fully automatic, monitoring applications. Open-path extremely flexible and, due to a The latest generation of analysers bring improved Monitoring System minimum of human intervention, cost-effective to performance, less drift and less temperature run. Every minute, several thousand cubic metres coefficient as a result of the use of advanced of air interact with a beam of light between a electronic, surface-mounted components and light-source and a receiver to provide a more improved control algorithms. The number of representative sample than can obtained with printed circuit boards has been halved and all cards point sampling techniques. are interchangeable between machines leading to One ET system will operate several light-paths easier and quicker card replacement. An extensive continuously measuring multiple gases over paths of internal Data Acquisition System, utilising the up to 1 km long. Any gas specified in the system’s analysers’ internal records, is capable of logging software can be measured, providing a facility to multiple parameters to a total of 1 million records. meet specific needs in a wide variety of applications. ET gas analysers are MCERTS and US EPA ET systems are MCERTS, TÜV and US EPA approved. approved. 100 UV Fluorescent Series Combines the proven UV fluorescent principle ET System 300 Multi-gas System with state-of-the-art microprocessor technology to This high performance package is designed for provide accurate and dependable measurements of urban, trend, fence-line, street canyon and model SO2, H2S, TRS, and sulphur compounds. validation applications. The system is available in three configurations – Basic (SO2, NO2 and O3), 200 Chemiluminescent Series BTX (benzene, toluene and xylene) and Basic/BTX Provides the sensitivity, stability and ease of use (combining all compounds). needed for ambient or continuous dilution monitoring of NO-NO2-NOX, NH3 and O3. 300 IR Absorption Series Measures low ranges of CO, CO2 and N2O by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to Beer-Lambert law. 400 UV Absorption Series Microprocessor-based with simple, multi-tasking, menu-driven software, for single pass, single path measurements of O3. 700 Mass Flow Calibrator Series Combines highly accurate mass flow controllers and compressed sources of standard gases to provide calibration gases for multi-point span and zero checks. ET monitoring system using point source analysers
  • 3.
    Mercury Monitoring VOC/HC Monitoring Continuous Ultra-Trace GC955 POPC/VOC/BTX Analyser Mercury Analyser Measures ozone precursors in ambient air. Two Continuous, simple and unattended operation separate sample and column systems are used to providing precision analysis of total gaseous measure C2-C5 and C6-C10 fractions. Methane mercury in ambient air with an update rate as low and non-methane compounds are measured as 2.5 minutes and a detection limit of <0.1 ng/m3 separately without relying on the efficiency of a (12 parts per quadrillion by volume). catalytic converter. Continuous VOCHC analyser Continuous mercury analyser Services Meteorological To complement the ET portfolio, EnviroService include flexible, quality-assured, service and Instrumentation maintenance contracts managed by highly A full range of instrumentation and systems from qualified and strategically located technicians leading manufacturers including solid state wind sensors, and engineers. barometric pressure sensors, precipitation gauges, The EnviroHire facility carries the largest air temperature sensors, solar sensors and AutoMet™ - stock of environmental monitoring equipment a complete, digital meteorological monitoring system in the UK or Europe offering a range of that provides instant access to weather information. instruments and systems that will cover almost any short- or long-term project. Air Quality Software • Automatic data collection • Statistical analysis • Airquality forecasting • Dispersion modelling • Internet public display
  • 4.
    Air Quality Monitoring IntegratedDigital Technology Integrated Digital Technology completely removes the need to Key features and use expensive, low technology, analogue dataloggers. Data is user benefits transmitted via telephone modem, GSM unit (cellular telephone network), Internet or to a dedicated site PC as required. • Simple, inexpensive analyser integration using Integrated As each analyser is able to store up to 5 years data/diagnostic Digital Technology information in internal memory and, by fully utilising the RS232 • Fully exploits analysers’fast, RS232 capabilities i.e. powerful capabilities, many benefits can accrue to the user including: bi-directional communication • Full remote control of system via modem/GSM unit or digital data transfer Internet allowing health checks and calibration routines • Full remoteGSM unit allowingvia modem or control of system from the office remote calibration checks, etc • Data collection of user defined averages plus span, • Flexible and expandable systems zero and diagnostic data • Compatible with EnviMan software • Remote control and calibration activation of individual • Internationally approved analysers analyser set-up (i.e. time, range, etc). • Span/zero data collection and graphing • Flexible calibrationzero and span including internal options (IZS) • Fast, remote troubleshooting by ET Technical Support Engineers. • Up most years parts warranty on to 5 analysers Flexible calibration options • Choice of ET service contracts Unlike some suppliers, we can offer a choice of automatic or manual calibration systems to meet a client’s exact requirements. • Simple operation and maintenance. Low running costs Choose from a range of systems including permeation tubes, certified gas cylinders and dynamic dilution calibrators. • EnviroHire equipment rental facilities available SM 200 combined dust monitor/sampler Monitoring for Life EnviroTechnology Services plc Advanced Environmental Systems - Sales, Hire and Services Kingfisher Business Park, London Road, Stroud, Gloucestershire, GL5 2BY Tel: +44 (0)1453 733200 Fax: +44 (0)1453 733201 Email: info@et.co.uk www.et.co.uk