Electrical Engineering Training Series
Electrical Power System Protection & Relay
Coordination Engineering Training
DEVELOP Oil&Gas Training Center menyelenggarakan Training Electrical Power
System Protection & Relay Coordination Engineering yang akan mengajarkan kepada
Anda tentang Prinsip-prinsip Power System Protection Principles,Skema esential untuk
Electrical Protection System, Relay Coordination System beserta optimalisasi
penerapannya.
DEVELOP menerapkan Syllabus Training Electrical Power System Protection & Relay
Coordination Engineering dengan tahap-tahap pembelajaran berkualitas sbb :
Sesi 1-2 Power System Protection Principles,Basic Protection Schemas & Essential
Qualities of Protection
 Power System Protection Fundamentals and Protection System Elements
 Basic Protection Schemas
 Essential Qualities of Protection
 Electrical Power System Exposure
 Blackouts
 Faults on Power System Risk
 Mechanical Damage During Short Circuits
 Protective Relays Design Criteria
 Unrestricted Protection
Sesi 3-4 Relay System Overview, Advantages & Enhancements
 Relay System Coordination Overview & Advantages
 Types of Relays
 Three-Phase Diagram of the Protection Team & DC Tripping Circuit
 Circuit Breakers, Voltage Transformers
 Relay Panels & Faults Detect by Relays
 Primary Protection Zone Overlapping & Backup Protection
 Short-Circuit Type Distribution (Single-Phase-Ground,Phase-Phase-
Ground,Phase-Phase,Three-Phase)
 Balanced and Unbalanced Conditions
 Overcurrent Relays & Inverse Relays
 50/51 Relay Coordination
 Directional Overcurrent Protection (Bus protection, Transformer
protection,Generator protection,Line protection,Large motor protection,Reactor
protection,Capacitor bank protection,Compound equipment protection)
 Differential Protection
Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek
langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata.
Materi Training di DEVELOP Training Center (TM) dirancang khusus oleh para praktisi
designer & engineer sesuai dengan kebutuhan project. Anda akan mendapat sharing ilmu
langsung dari para praktisi yang berpengalaman bertahun-tahun.
Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek
langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata.
Contact us NOW at :
DEVELOP Oil and Gas Training Center
Perkantoran Permata Eksekutif Tower 2,Lobby Lantai 2
Jalan Raya Pos Pengumben,Kebon Jeruk,Jakarta Barat INDONESIA Phone : 021 3030
5374 Direct 0852 1068 5004 Email : info@oilgascourse.com
Website : www.oilgascourse.com

Electrical power protection and relay coordination training

  • 1.
    Electrical Engineering TrainingSeries Electrical Power System Protection & Relay Coordination Engineering Training DEVELOP Oil&Gas Training Center menyelenggarakan Training Electrical Power System Protection & Relay Coordination Engineering yang akan mengajarkan kepada Anda tentang Prinsip-prinsip Power System Protection Principles,Skema esential untuk Electrical Protection System, Relay Coordination System beserta optimalisasi penerapannya. DEVELOP menerapkan Syllabus Training Electrical Power System Protection & Relay Coordination Engineering dengan tahap-tahap pembelajaran berkualitas sbb : Sesi 1-2 Power System Protection Principles,Basic Protection Schemas & Essential Qualities of Protection  Power System Protection Fundamentals and Protection System Elements  Basic Protection Schemas
  • 2.
     Essential Qualitiesof Protection  Electrical Power System Exposure  Blackouts  Faults on Power System Risk  Mechanical Damage During Short Circuits  Protective Relays Design Criteria  Unrestricted Protection Sesi 3-4 Relay System Overview, Advantages & Enhancements  Relay System Coordination Overview & Advantages  Types of Relays  Three-Phase Diagram of the Protection Team & DC Tripping Circuit  Circuit Breakers, Voltage Transformers  Relay Panels & Faults Detect by Relays  Primary Protection Zone Overlapping & Backup Protection  Short-Circuit Type Distribution (Single-Phase-Ground,Phase-Phase- Ground,Phase-Phase,Three-Phase)  Balanced and Unbalanced Conditions  Overcurrent Relays & Inverse Relays  50/51 Relay Coordination  Directional Overcurrent Protection (Bus protection, Transformer protection,Generator protection,Line protection,Large motor protection,Reactor protection,Capacitor bank protection,Compound equipment protection)  Differential Protection Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata.
  • 3.
    Materi Training diDEVELOP Training Center (TM) dirancang khusus oleh para praktisi designer & engineer sesuai dengan kebutuhan project. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun. Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata. Contact us NOW at : DEVELOP Oil and Gas Training Center Perkantoran Permata Eksekutif Tower 2,Lobby Lantai 2 Jalan Raya Pos Pengumben,Kebon Jeruk,Jakarta Barat INDONESIA Phone : 021 3030 5374 Direct 0852 1068 5004 Email : info@oilgascourse.com Website : www.oilgascourse.com