This document introduces the Albion Ultrasteel unvented hot water cylinder range. It provides details on the product line including capacities from 120 to 300 liters, materials used, insulation, heat exchanger design, fittings and connections. It highlights features such as durable duplex stainless steel construction, high efficiency coil-in-coil heat exchanger, 50mm foam insulation and long life immersion heaters. Specification tables and diagrams are included showing cylinder dimensions, weights and reheat performance. The document emphasizes the range's quality, reliability and compatibility with solar heating systems.
The aim of this experiment is to measurement linear thermal along z direction conductivity and to investigate and verify Fourier’s Law for linear heat conduction along z direction and we proved that K is inversely proportional with ΔT, and we have many errors in our experiment that made the result not clear.
To demonstrate the effect of cross sectional area on the heat rate.
To measure the temperature distribution for unsteady state conduction of heat through the uniform plane wall and the wall of the thick cylinder.
The experiment demonstrates heat conduction in radial conduction models It
allows us to obtain experimentally the coefficient of thermal conductivity of some unknown materials and in this way, to understand the factors and parameters that affect the rates of heat transfer.
To understand the use of the Fourier Rate Equation in determining the rate of heat flow for of energy through the wall of a cylinder (radial energy flow).
To use the equation to determine the constant of proportionality (the thermal conductivity, k) of the disk material.
To observe unsteady conduction of heat
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIESManohar Tatwawadi
The presentation gives an idea as to how the compressed air system is designed and the performance of the compressed air system. The losses, conservation of energy, the cost of leakages etc are discussed in the presentation
The aim of this experiment is to measurement linear thermal along z direction conductivity and to investigate and verify Fourier’s Law for linear heat conduction along z direction and we proved that K is inversely proportional with ΔT, and we have many errors in our experiment that made the result not clear.
To demonstrate the effect of cross sectional area on the heat rate.
To measure the temperature distribution for unsteady state conduction of heat through the uniform plane wall and the wall of the thick cylinder.
The experiment demonstrates heat conduction in radial conduction models It
allows us to obtain experimentally the coefficient of thermal conductivity of some unknown materials and in this way, to understand the factors and parameters that affect the rates of heat transfer.
To understand the use of the Fourier Rate Equation in determining the rate of heat flow for of energy through the wall of a cylinder (radial energy flow).
To use the equation to determine the constant of proportionality (the thermal conductivity, k) of the disk material.
To observe unsteady conduction of heat
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIESManohar Tatwawadi
The presentation gives an idea as to how the compressed air system is designed and the performance of the compressed air system. The losses, conservation of energy, the cost of leakages etc are discussed in the presentation
Measurement of Flow Rate and Impact Force on Different Vanes through Impact o...Farzad Hossain
The objectives of the paper are to conduct an investigation into the reaction force generated by the impact of a jet of water onto various target vanes and to compare between experimental and theoretical forces which are exerted by the jet. The procedure for this experiment is to bring the weight cup in the initial position by applying weight when the flow rate is varied. It can be possible to repeat the same experiment by changing different target vanes. Moreover, the effect of different target vanes can be seen at a constant flow rate by changing the type of target vanes and applying different amounts of weights to bring the weight cup in the initial position. The vanes used in this experiment can be categorized into four geometries. Flat, inclined, spherical and conical vanes are used for this experiment. Experimental and theoretical forces and the percentage of error can be calculated in this experiment. Here, the theoretical forces are depended upon weights applied on the weight cup and the experimental forces are depended on flow rate, nozzle exit velocity, impact velocity and shape of the vanes.
Centrifugal compressor anti-surge control system modellingIJECEIAES
From the middle of XX century, natural gas is an important mineral, widely used in the energy sector. Transportation of natural gas is carried out via gas pipeline networks and compression stations. One of the key features which need to be implemented for any centrifugal gas compressor is a surge protection. This article describes the method and develops software application intended for simulation and study of surge protection system of a centrifugal compressor used in modern gas compression stations. Within the article research method, modelling environment’s block diagram, proposed algorithms and results are described. For surge cases control and prediction, Anti-surge control block implemented which based on practical experience and centrifugal compressor theory. To avoid complicated energy balancing differential equations the volumetric flow calculation algorithm proposed which is used in combination with Redlich-Kwong equation of state. Developed software’s adequacy test performed through modeling of onestage gas compression scheme at rated speed with comparison of parameters with reference commercial software and verification of the anti-surge control system.
Measurement of Flow Rate and Impact Force on Different Vanes through Impact o...Farzad Hossain
The objectives of the paper are to conduct an investigation into the reaction force generated by the impact of a jet of water onto various target vanes and to compare between experimental and theoretical forces which are exerted by the jet. The procedure for this experiment is to bring the weight cup in the initial position by applying weight when the flow rate is varied. It can be possible to repeat the same experiment by changing different target vanes. Moreover, the effect of different target vanes can be seen at a constant flow rate by changing the type of target vanes and applying different amounts of weights to bring the weight cup in the initial position. The vanes used in this experiment can be categorized into four geometries. Flat, inclined, spherical and conical vanes are used for this experiment. Experimental and theoretical forces and the percentage of error can be calculated in this experiment. Here, the theoretical forces are depended upon weights applied on the weight cup and the experimental forces are depended on flow rate, nozzle exit velocity, impact velocity and shape of the vanes.
Centrifugal compressor anti-surge control system modellingIJECEIAES
From the middle of XX century, natural gas is an important mineral, widely used in the energy sector. Transportation of natural gas is carried out via gas pipeline networks and compression stations. One of the key features which need to be implemented for any centrifugal gas compressor is a surge protection. This article describes the method and develops software application intended for simulation and study of surge protection system of a centrifugal compressor used in modern gas compression stations. Within the article research method, modelling environment’s block diagram, proposed algorithms and results are described. For surge cases control and prediction, Anti-surge control block implemented which based on practical experience and centrifugal compressor theory. To avoid complicated energy balancing differential equations the volumetric flow calculation algorithm proposed which is used in combination with Redlich-Kwong equation of state. Developed software’s adequacy test performed through modeling of onestage gas compression scheme at rated speed with comparison of parameters with reference commercial software and verification of the anti-surge control system.
The combination of three factors such geometry configuration, optimized pipe diameters and special high efficiency fins, allows to improve the following features:
§ maximum capacity in relation to the heat exchanger size;
§ optimized pressure drops of the primary fluid thanks to the use of different tube diameters and achievable circuits; § possibility to select the optimal unit thanks to the use of different modules.
Service center ariston depok swh Sebuah pemanas air tenaga matahari (Water Heater) dapat menjadi solusi yang tepat untuk rumah anda. Jika anda frustrasi dengan biaya listrik rumah anda, mungkin sudah saatnya untuk menjangkau solusi energi yang lebih efisien. Anda bisa mendapatkan pemanas air lain yang jauh lebih efisien daripada yang anda miliki. Tenaga matahari tersedia melimpah tak terbatas untuk anda, ini solusi yang memberi manfaat untuk Anda
Harga Ariston di Jakarta jual distributor Water Heater pemanas air dari Ariston Center 15-30-50-80-100 AN – Pro R liter Jual Pemanas Air ARISTON original terbaru, terbaik dan terlengkap. Dapatkan harga Pemanas AirARISTON special hari ini. Free ongkir.
Fikri Mandiri Jaya
Service Ariston
Telp : +62 2184983405 - Fax : +62 2184982055
Mobile : 081313462267 - 087887330287
Email : cs.fikrimandirijaya@yahoo.com
Brochure on Residential and Commercial Heat Pump System H2i by Mitsubishi Electric Available at Unique Indoor Comfort, located in the Northshore of Chicago
Ever wondered exactly what we offer for geothermal heat pumps? Check out this slide show for an in depth introduction to our residential product line, along with our history, a tour of the plant, and more!
If you are looking for a better solution than VRF systems look no further. AERMEC is now introducing their simultaneous hot and chilled water heat pumps to the North American HVAC market!
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressionsVictor Morales
K8sGPT is a tool that analyzes and diagnoses Kubernetes clusters. This presentation was used to share the requirements and dependencies to deploy K8sGPT in a local environment.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Forklift Classes Overview by Intella PartsIntella Parts
Discover the different forklift classes and their specific applications. Learn how to choose the right forklift for your needs to ensure safety, efficiency, and compliance in your operations.
For more technical information, visit our website https://intellaparts.com
HEAP SORT ILLUSTRATED WITH HEAPIFY, BUILD HEAP FOR DYNAMIC ARRAYS.
Heap sort is a comparison-based sorting technique based on Binary Heap data structure. It is similar to the selection sort where we first find the minimum element and place the minimum element at the beginning. Repeat the same process for the remaining elements.
6th International Conference on Machine Learning & Applications (CMLA 2024)ClaraZara1
6th International Conference on Machine Learning & Applications (CMLA 2024) will provide an excellent international forum for sharing knowledge and results in theory, methodology and applications of on Machine Learning & Applications.
We have compiled the most important slides from each speaker's presentation. This year’s compilation, available for free, captures the key insights and contributions shared during the DfMAy 2024 conference.
Understanding Inductive Bias in Machine LearningSUTEJAS
This presentation explores the concept of inductive bias in machine learning. It explains how algorithms come with built-in assumptions and preferences that guide the learning process. You'll learn about the different types of inductive bias and how they can impact the performance and generalizability of machine learning models.
The presentation also covers the positive and negative aspects of inductive bias, along with strategies for mitigating potential drawbacks. We'll explore examples of how bias manifests in algorithms like neural networks and decision trees.
By understanding inductive bias, you can gain valuable insights into how machine learning models work and make informed decisions when building and deploying them.
Using recycled concrete aggregates (RCA) for pavements is crucial to achieving sustainability. Implementing RCA for new pavement can minimize carbon footprint, conserve natural resources, reduce harmful emissions, and lower life cycle costs. Compared to natural aggregate (NA), RCA pavement has fewer comprehensive studies and sustainability assessments.
Hierarchical Digital Twin of a Naval Power SystemKerry Sado
A hierarchical digital twin of a Naval DC power system has been developed and experimentally verified. Similar to other state-of-the-art digital twins, this technology creates a digital replica of the physical system executed in real-time or faster, which can modify hardware controls. However, its advantage stems from distributing computational efforts by utilizing a hierarchical structure composed of lower-level digital twin blocks and a higher-level system digital twin. Each digital twin block is associated with a physical subsystem of the hardware and communicates with a singular system digital twin, which creates a system-level response. By extracting information from each level of the hierarchy, power system controls of the hardware were reconfigured autonomously. This hierarchical digital twin development offers several advantages over other digital twins, particularly in the field of naval power systems. The hierarchical structure allows for greater computational efficiency and scalability while the ability to autonomously reconfigure hardware controls offers increased flexibility and responsiveness. The hierarchical decomposition and models utilized were well aligned with the physical twin, as indicated by the maximum deviations between the developed digital twin hierarchy and the hardware.
2. Exceptional value for money package!
DESIGNED FOR THE
‘ONE-OFF’ INSTALLER
• Market leading brand
• Highest quality materials
• Highest manufacturing quality
• National Technical & Service support
• Fully approved
• 25-year Guarantee
• Competitively priced
3. PRODUCT RANGE
• Albion Ultrasteel Standard
– 6 capacities
• 120 to 300 ltrs
– Direct and Indirect
• Albion Ultrasteel Solar
– 4 capacities
• 180 to 300 ltrs
– Direct and Indirect
4. QUALITY INSIDE…
Temperature and pressure
relief valve operating at
90ºC / 7 bar
Duplex stainless steel
cylinder, pressure tested
to 15 bar
Totally insulated with
environmentally friendly
50mm thick HCFC and
CFC-free foam
22mm cold feed with
diffuser
22mm coil connections
Long life Incoloy
sheathed immersion
heater
Highly efficient coil-in-coil
heat exchanger
5. 22mm hot water outlet
High quality finish
Factory fitted temperature
and pressure relief valve
Wide range of models
from 120 litres to 300 litres
Direct and Indirect
versions
Solar models also
available
High quality controls
High grade immersion heater(s)
…AND OUT!
6. HIGH PERFORMANCE ‘COIL-IN-COIL’
HEAT EXCHANGER
• High output ratings 16.52kW to
22.38kW
• More efficient transfer of energy
• Fast heat recovery
• Positioned low in the cylinder to
achieve more usable hot water
• 90-95% compared with 75-80% for
conventional coil
• Cold water inlet diffuser reduces
turbulence to minimise mixing of
hot and cold water
7. DUPLEX STAINLESS
STEEL CYLINDER
• Manufactured from high grade Duplex
stainless steel
• No anode is required
• Superior corrosion resistance – resists
all forms of corrosion including pitting
corrosion, crevice corrosion, uniform
corrosion and stress corrosion cracking
• Post-weld treatment for reliability and
long life
Post-weld treated
No post-weld treatment
8. INSULATION AND HEAT LOSS
• 50mm thick void free layer of
CFC/HCFC-free expanded
polyurethane foam lagging
• One-piece insulation cannot
separate in transit to ensure
effectiveness
• Fully insulated base
• Low standing heat loss
• Environmentally friendly
– Ozone Depletion Potential of Zero
– Global Warming Potential of One
9. • Heat loss figures meet CHeSS Best Practice guidelines for insulation
• Part L 2010 compliant
MINIMAL HEAT LOSS
10. LONG LIFE IMMERSION HEATERS
• Incoloy sheathed for longer
life
• Low watts density for quiet
operation
• 3 kW rated
– 6kW and 9kW options
available on request
• High quality Titanium
immersion heaters available
for Commercial / Industrial
installations
12. PRESSURE AND FLOW RATES
• Exceeds performance of comparable vented systems, giving
powerful showers & fast filling baths
• Delivers hot water at flow rates up to 50 litres/min.
13. INSTALLER FRIENDLY DESIGN
• Albion Ultrasteel comes as a complete package – just add
pipework!
High flow rate inlet
control set
Two port valve Expansion vessel Dual thermostat
Immersion heater Temperature and
pressure relief valve
Tundish
14. ALBION ULTRASTEEL - DIRECT
22mm hot
draw-off
22mm
secondary return
(not always fitted)
½” F PTRV
boss
22mm cold feed
with dip pipe to
deflector in bottom
of cylinder
D F
15. ALBION ULTRASTEEL - DIRECT
CODE CAPACITY HEIGHT DIAMETER D F WEIGHT
WEIGHT (Kg-EMPTY) (Kg-FULL)
17. ALBION ULTRASTEEL - INDIRECT
22mm hot draw-off
22mm secondary
return (not always
fitted)
½” F PTRV boss
22mm cold feed with
dip pipe to deflector
in bottom of cylinder
second immersion
heater (not always fitted)
dry stat pocket
ABCDEF
18. ALBION ULTRASTEEL - INDIRECT
CODE CAPACITY HEIGHT DIAMETER A B C D E F WEIGHT
WEIGHT (Kg-EMPTY) (Kg-FULL)
20. ALBION ULTRASTEEL SOLAR - DIRECT
All models feature
2 electric immersion
heaters for a back
up heating – either
of them is suitable
for use in
conjunction with ‘low
tariff’ electricity (e.g.
Economy 7 or 10).
Coil-in-coil designed
to accept input from
renewable energy
source, such as
Kingspan Solar Flat
Plate Panel or
Thermomax Vacuum
Tube Solar Thermal
Collectors
21. TECHNICAL SPECIFICATION – DIRECT SOLAR
MODELS
22mm cold feed
with dip pipe to
deflector in bottom
of cylinder
½”F PTRV boss
22mm hot draw-off
ABCDEF G
dry stat pockets
22mm secondary
return (not always
fitted)
22. TECHNICAL SPECIFICATION – DIRECT SOLAR
MODELS
CODE CAPACITY HEIGHT DIAMETER A B C D E F G WEIGHT
WEIGHT (Kg-EMPTY) (Kg-FULL)
23. ALBION ULTRASTEEL SOLAR -
INDIRECT
All models feature electric
immersion heater for a
back up heating –
suitable for use in
conjunction with ‘low tariff’
electricity (e.g. Economy
7 or 10)
Upper coil can be
connected to traditional
source of heat, such as
gas, oil or electric boiler
Lower coil is designed to
accept input from
renewable energy
source, such as
Kingspan Solar Flat
Plate Panel or
Thermomax Vacuum
Tube Solar Thermal
Collectors
24. TECHNICAL SPECIFICATION – INDIRECT SOLAR MODELS
CODE CAPACITY HEIGHT DIAMETER A B C D E F G H WEIGHT
WEIGHT (Kg-EMPTY) (Kg-FULL)
dry stat pockets ½”F PTRV boss
22mm hot draw-off
22mm secondary
return (not always
fitted)
22mm cold feed
with dip pipe to
deflector in
bottom of cylinder
dry stat pocket
ABCEF G HD
25. COIL SPECIFICATION & WATER CAPACITIES
• 30% of the total volume is dedicated renewable energy capacity
• 70% of the volume can be heated in the traditional way via an upper
coil on days when solar energy is not sufficient to heat the full
contents of the unit or on days when additional energy is required
28. GUARANTEE
• Albion Ultrasteel’s stainless steel
vessel features a fully transferable
25-year anti-corrosion guarantee
• The expansion vessel and cold
water controls supplied with the
cylinder carry a 5-year guarantee
• All other components fitted to/or
supplied with the unit carry
a 2-year guarantee
29. PRODUCT APPROVALS
• BEAB approved immersion
heater
• WRAS approved to the Water
Regulations
• WRc-NSF approved for
Building Regulation G3 & L
• Manufactured in the UK in an
BS EN ISO 9001:2008
registered factory