Disha NEET Physics Guide for classes 11 and 12.pdf
User manual of advanced controller
1. Page - 1 - of 9
200W-600 W series
Model no.: SSWC-06-1224-TA
Version:2011-5.0ver
2. Page - 2 - of 9
Notes
Thank you for ordering our controller. Please read manual carefully before installation
and keep it properly.
To make this model running properly, installation should be strictly in accordance with
manual and done by experienced technicist
Please use insolating tool to install this machine, don‟t use bad tools.
Please don‟t use low quality battery to avoid leakage, rust or burn.
Please don‟t use thin or low quality cable to avoid leakage or fire.
Do not open cover and maintain personally.
Please don‟t reverse battery anode and cathode, don‟t reverse solar panel anode and
cathode.
Keep it away from moist, rain, insolation, severe dust, shaking, corrosion and
Intensive or under intense electromagnetic interference. Do not install or use this
machine in an environment mixed with combustible gas.
This machine prohibited around the place with any flammable, explosive and
dangerous goods.
Keep any symbols on the controller complete. To avoid accidents, keep it away from
this children.
3. Page - 3 - of 9
1. General Description
The advanced wind/solar hybrid controller is specially designed for high-end small-scale wind/solar
hybrid system and especially suitable for wind/solar hybrid street light system and wind/solar hybrid
monitoring system.
2. Product feature
Independent Boost Circuit: Solved the charging efficiency of the low-power vertical wind generator
MPPT charging way, make sure power max. input to battery and high charging efficiency obtained.
Be able to use for 200W-600W wind turbine with high compatibility.
12V/24V System Automatic Recognition function.
Allow to connection reversely by battery or solar panel positive negative polarity.
Mini-size, be easy to install.
RS232 data communication with computer (we supply software)
3. Protection Functions
Solar cells reverse charging, solar cells anti-reverse connection
Battery over-charging, battery over-discharge, battery anti-reverse connection.
Over-load, load anti-reverse connection.
Wind turbine current and voltage limited, rotation limited, dump-load to brake.
4. Controller output DC power illumination
This device be able to do following 2 design output type, please request which type are your
expectation before buy.
* NOW, YOUR CHOICE TYPE IS √ ITEM.
(I) 1th and 2nd
line output are all 24hours constant DC power for monitor system.
Please ignore below about lighter or timer setting, this function was invalidation.
(II) 1th and 2nd
line output are: full power + half power + turn off + morning lighting
5. Time setting illumination (setting way please refer to item9.)
“T1-X ”mean 1th line output,“T2-X”mean 2nd
line output(for example T1-X)
T1-1 :default value be 5 , mean full-power time is 5hours,then go intoT1-2 step.
T1-2 :default value be 3 , mean half- power time is 3hours,then go intoT1-3 step.
T1-3 :default value be 3 , mean turn off time is 3hours,then go intoT1-4 step.
T1-4 :this process is balance of whole night time. And turn off lamp while day. This value would not show
T1-1 full power T1-2 half power T1-3 turn off T1-4 morning lighting
Night – turn on Day- turn offBy light sensor
4. Page - 4 - of 9
S
on LCD, so this value is not adjustable. Of course , you could to cover this process by -2,-3 value with longer time.
6. Model Description
After installing wind wind/solar hybrid system, please connect the controller accurately as the sequential
operation.
7. Connection process
Graph 2, terminal connection
Graph 1, wind&solar hybrid system
Picture 1, wind&solar hybrid system wiring
Picture 1, wind&solar hybrid system wiring
Picture 1, wind&solar hybrid system wiring
Company code
S W C-06-1224 -TA
Battery vol. 12V/24V auto
Wind turbine power 600W
controller(Controller)
wind(Wind Energy)
solar(Solar Energy)
Top advanced
5. Page - 5 - of 9
Please connect and operate system components strictly according to the steps below!
(I) Connect with Battery:
1. Connect accumulate battery wire to “BATTERY” terminal which rear of device. Please use the
cuprum cable which about 6mm2
and less than 1m. Although the machine has reverse
connection protection, it is forbiden connecting the battery reversely !
After installing battery, this led will be twinkling approximate15 seconds once connected with battery for
device initial working.
(II) Connect with wind turbine:
Ensure wind turbine in brake status and then connect the wind turbine output lines to the “WIND INPUT”
terminals in back panel .
(III)Connect with solar panel:
If your system have solar panel, please connect the wire to “SOLAR INPUT” terminal rear of device.
Connection reversely is prohibited !
(IV)Connect with DC output:
Connect DC load to “DC OUTPUT” terminal : The first load should be connected to "+" and "-1" of the “DC
OUTPUT” terminals , The second load should be connected to "+" and "-2" of the “DC OUTPUT”
terminals. The modes of load output can be setted according to the requirements of system .( The
6. Page - 6 - of 9
half-power output is only applicable to LED light ).
8. LCD Display Instructions
LCD backlight is on after pressing any key. The backlight will auto-off 10 seconds later to save power
while stop pressing any key.
A) Description of Key-Press:
(+)key: key symbolizes increase or next one. In browsing window, press this key to check next
parameter. In setting window, press this key to check next adjustable parameter or increase the value of
the current parameter.
(—)key: key symbolizes decrease or previous one. In browsing window, press this key to check
the previous parameter. In setting window, press this key to check the previous adjustable parameter or
decrease the value of the current parameter.
B) Displayed Content Description:
LCD screen displays the following picture after turned on:
Press (-) key to next page:
9. System parameters setting Instructions
“ENTER” key:symbolizes set or confirm: press this key to access setting window. In setting window,
press this key to choice each parameter and go to next page.
“Esc” key: cancel or manual switch. In setting window, press this key to return to browsing window
and do not save the modified parameters.
Press “ENTER” to access following display of screen firstly.
Vd1: Battery over-discharge voltage
Vdr1:Battery over- discharge recovery voltage
Vu1: Battery over-charge voltage
Vur1: Battery over-charge recovery voltage
Vdl:21.0V
Vdrl:25.0V
Vul:28.8V
Vurl:26.5V
Uw: 20.8V
Us: 28.6V
Ub: 24.5V
Iw: 05.0A
Uw: wind-turbine voltage
Us: Solar panel voltage
Ub: battery voltage
Iw: charging current of wind-turbine
Is: 10.5A
STA: Normal
D/N: Day
E-b: 76%
Is: charging current of solar panel
STA: system status
D/N: show“DAY” or“Night”
E-b: power volume of battery
7. Page - 7 - of 9
Press “ENTER” key again to choose, Press (+) key or (-) key to adjust the value, each press means
increase or reduce 0.1V
Press “ENTER” key to next page:
Press “ENTER” to choose, Press (+) key or (-) key to adjust the value, each press means
increase or reduce 0.1V, each press means increase or reduce 1 hour while setting time
Press “ENTER” key to next page:
Press “ENTER” to choose, Press (+) key or (-) key to adjust the number, each press means
increase or reduce 0.1V, each press means increase or reduce 1 hour while setting time
Press “ENTER” key to next page:
Remind! This parameter must be modify by professional technician, general user re-setting is
prohibited!
Press “ENTER” key to next page:
Press “ENTER” key to save value set, and access to setting window again.
Press “ESC” key do not save value set and access to browsing window.
Remind!
Vf1: Wind-turbine dump protection voltage
T1-1: Line1 whole power output time
T1-2: Line1 half-power output time
T1-3: Line1 Turn-off output time
T2-1: Line2 whole power output time
T2-2: Line2 half power output time
T2-3: Line2 Turn-off output time
VsTH:Lamp turn-on while voltage of solar panel less
than it. And turn-off while more than it
Vf1:27.5V
T1-1:05h
T1-2:03h
T1-3:03h
T2-1:05h
T2-2:03h
T2-3:03h
VsTH:06.0V
It‟s saved
Press The „ENTER‟ or
The „ESC‟
VwTH : 18V
VwTH is mean rise voltage of wind turbine output. Please
mind 18v was rectified value, wind-turbine output
approximate 13vac, If be 12v system, will showing 8.0v.
wind turbine output approximate 6vac, controller will rise
up.
8. Page - 8 - of 9
When you have completed all setting, please to disconnection battery aim to power off controller, then
10seconds later, to re-start connection of battery to power on controller. This is intent to make sure the
program running in modified setting condition.
10. Performance Parameters
10.1 Wind generator control set-up definition:
Rated Wind Turbine Power 200W – 600W
Wind Turbine Maximum Input Power 800W
Wind Turbine Input Current Max. 30A
12V System Unload Voltage (Vf1) Factory default: 13.5V adjustable
24V System Unload Voltage (Vf1) Factory default: 27.0V adjustable
10.2 PV panel set-up definition
Max PV power (12v/24v) 150W / 300W
12V system max open circuit voltage 18.0V
24V system max open circuit voltage 36.0V
Solar panel max charge current 15.0A
10.3 Battery management definition
12V system voltage protection
Over-discharge Voltage factory default : 10.5V adjustable
Over-discharge Recovery Voltage factory default : 12.5V adjustable
Over-charge Voltage factory default : 14.4V adjustable
Over-charge Recovery Voltage factory default : 13.0V adjustable
24V system voltage protection
Over-discharge Voltage factory default : 21.0V adjustable
Over-discharge Recovery Voltage factory default : 25.0V adjustable
Over-charge Voltage factory default : 28.8V adjustable
Over-charge Recovery Voltage factory default : 26.0V adjustable
Output Set-up function:
Each Line Output Max. Current 10A
Each Line Output Max. Power (12V/24V) 120W / 150W
Output Mode Constant output
setting
Light sensor value ( VSTH) factory default : 6.0V adjustable
10.4 Product Conventional parameter
Display super large LED (Backlit)
9. Page - 9 - of 9
Display Content Battery Voltage, Charge Current, Wind Turbine Voltage/Current,
PV Voltage/Current, over-charge voltage, over-discharge voltag
e, battery value% ,day or Night and system status
Standard communication interface RS232(adjustable RS485,RJ45,GPRS etc.)
Operating temperature -20℃ ~ +50℃ / 35~85%RH(free from condensation.)
Altitude work ≤3000 meters above sea level
Protection class IP55
Dimension (LWH) 175mm X 145mm X 75mm
Net-weight 1.3 Kg
11. Warranty and after Sales Service
We provide 1 year warranty for our product from the date of delivery
If the product is exceed warranty or damaged by transportation, improper operation , human element,
force majeure, it is not under warranty.
12. Declare:
The product has applied for patent protection, counterfeiting will be subject to
legal sanctions. Our Company reserves the right to change products and
without notice when products update.