SlideShare a Scribd company logo
1 of 12
Download to read offline
AXPERT-HIVERT
Medium Voltage Drive
AN ISO 9001 : 2015 COMPANY
02
Introduction
Amtech is one of the leading manufacturers of low voltage AC Drive
with world class manufacturing facility and strong in-house R&D.
NowAmtech has come up with the state-of-art technology innovated
Axpert-Hivert Series Medium Voltage VFD. With the strong technical
support system and global network, Amtech is in position to provide
highest up time in the industry.
Product Structure
Transformer Cabinet
Isolating Transformer: Secondary multi-winding output
provides phase-shifted power supply to the power cell unit. This
greatly improves the current waveform on grid side and reduces
the harmonic interference of the equipment to power grid.
Transformer Cooling Fan: Cooling fan specifically for dry
transformer is configured according to different capacity.
Power Unit Cabinet
Controller: For space vector PWM control, signal acquisition and processing, communication between units via fiber optics for completely
electrical isolation.
Power Unit: Modular design of power cell units, interchangeable and easy to manufacture, install and repair.
Interface board: The core of the new I/O interface board is S7-200 SMART CPU, the module comes standard with Ethernet interface,
supports Siemens S7 protocol, TCP/IP protocol and effectively supporting a variety of terminal connections. In addition, the CPU module is
integrated with one RS485 interface, able to communicate with the third-party equipment such as the MV drive and touch screen.At the same
time, it is equipped with expansion CM01 signal board to realize RS232 / RS485 free communication and support Profibus and Ethernet
TCP/IPcommunication protocol.
Monitoring HMI: 10 inch touch screen, control system status and monitoring, powerful data control (data logging, diagnostics, and
information), user-centric convenience (HD display, high data throughput, user-friendly interface).
By-pass Cabinet or Switching Cabinet (Optional)
The by-pass cabinet or switching cabinet may employ isolating breaker, vacuum contactor or the combination, depending on the user's
working conditions. The function of by-pass cabinet is to put the motor into operation on mains power supply after the inverter exits, so
as to ensure the continuity of user's process. The switching cabinet is designed to divert the inverter output to different motors.
System Cooling Fan
High efficiency fan from world renowned manufacturer. The benefits are large air flow and long service life.
Cooling fan
Power Unit/control cabinet
11 kV cabinet outline drawing (including manual bypass cabinet)
Transformer cabinet Manual bypass cabinet
1. Topology Structure of Main Circuit
3.3 kV Series: ,
Consisting of 9 power cells; 3 power cells are connected in series to form one phase 3-phase Y-type connection.
4.16 kV Series: Consisting of 12 power cells; 4 power cells are connected in series to form one phase 3-phase Y-type connection.
,
6.6 kV Series: ,
Consisting of 18 power cells; 6 power cells are connected in series to form one phase 3-phase Y-type connection.
11 kV Series: ,
Consisting of 27 power cells; 9 power cells are connected in series to form one phase 3-phase Y-type connection.
Working Principle of Inverter
Axpert-Hivert Series Medium Voltage Drive adopts AC-DC-AC direct medium voltage input and output
and employs IGBT based power cells in series. The medium voltage output is the result of the
overlapping waveforms from each power cell. The Axpert-Hivert Series has very high reliability, thanks to
the proven technology of normal voltage inverter.
Main Circuit Diagram of Axpert-Hivert Series 6.6 kV Medium Voltage Drive
03
2. Voltage Overlap Diagram
Each phase of Axpert-Hivert Series Medium Voltage Drive consists of multiple power cells connected in series, and each power unit is isolated
by the secondary winding of isolating transformer. By changing the quantity of units in series, the phase-shifted power supply can easily obtain
the output of different voltage level, without being subjected to the restriction of the power devices for their voltage level performance.Assuming
that each phase of an inverter rated 6.6 kV consists of 6 power cells and the rated voltage of power cell is 690V, the phase voltage will be 3810 V
after connection in series (the corresponding line voltage is 6.6 kV). Each phase of 11 kV Inverter consists of 9 power units, the rated voltage of
power unit is 710V, and the working voltage is 710V.
3. Structural Diagram of Power Unit
Axpert-Hivert Series Medium Voltage Drive consists of
multiple power cells connected in series, and each power
unit is powered by the secondary isolating winding of the
input isolating transformer. The power unit is of AC-DC-AC
structure, equivalent to a low-voltage power source inverter
of 3-phase input single-phase output. As power units are
fully identical in structure and electrical performance, very
easy for maintenance and replacement.
The power unit receives the signal via optical fiber and adopts space vector sine wave pulse (PWM) to control the conductivity and disconnection
of Q1~Q4 IGBT, outputting single-phase pulse width modulation waveform. Each unit is only possible to have three states of output voltage.
When Q1 and Q4 are connected, the output voltage state of L1 and L2 will be 1; when Q2 and Q3 are connected, the output voltage state of L1
and L2 will be -1; and when Q1 and Q2, or Q3 and Q4 are connected, the output voltage state of L1 and L2 will be 0.
Inverter Series Quantity of Series Unit Rated Voltage Unit Working Voltage Output Phase Voltage Output Line Voltage Number of Voltage
Unto for Each Phase (V) (V) (V) (KV) Level tor Each Phase
3.3 kV 3 690 635 1905 3.3 7
4.16 kV 4 690 600 2402 4.16 9
6.6 kV 6 690 635 3810 6.6 13
11 kV 9 710 710 6390 11 19
Fuse Diode Rectifier DC BUS Inverter
R
S
T
L1
L2
Q1 Q2
Q3 Q4
3.3 kV Series 11 kV Series
3300V
Line Voltage
1905V
Phase Voltage
635
635
635
635
635
635 635
635
635
710
710
710
710
710
710
710
710
710
710
710
710
710
710
710
710
710
710
11000V
Line Voltage
6390V
Phase Voltage
710
710
710
710
710
710
710
710
710
6.6 kV Series
6600V
Line Voltage
3810V
Phase Voltage
635
635
635
635
635
635
635
635
635
635 635
635
635
635
635
635
635 635
04
4. External Control System Diagram
05
I/O Interface
High-quality Current Input
Through phase-shift step down voltage, the secondary winding of isolating transformer on input side provides isolated power source to each
power cell. For 3.3 kV, it is equivalent to 18-pulse, (24-pulse for 4.16 kV, 36-pulse for 6.6 kV, 54-pulse for 11 kV) un-controlled rectifying input.
This eliminates most of the harmonic current caused by each power cell and greatly reduces the generation of harmonics on grid side.
The harmonic voltage and THD caused to electric grid by the inverter meets the most stringent requirements for THD as specified in IEEE
Std 519-1992 and GB/T14549-93 (Quality of Electric Energy Supply Harmonics in Public Supply Networks). The inverter does not require
installation of any filter, but it can protect the surrounding equipment from harmonic interference. The power factor within normal range of
speed regulation is over 0.95, so the power-factor compensation capacitors are not required.
Reduces the reactive input and decreases the supply capacity.
Perfect Output Performance
The units are connected in series and of PWM overlap output. Each phase consists of 6 units for 6.6 kV series inverter, and 9 units for 11 kV
series. This results in greatly reduced output of harmonic content, so that the output waveform is nearly perfect sine wave. In comparison with
other types of high voltage large-capacity drives, Axpert-Hivert Series MVD has following advantages:
No output filter required.
Able to drive common high-voltage motor without increasing the motor temperature or decreasing the motor capacity.
Motor cable is free of any length restriction.
Protective insulation of motor is free from the damage of dv/dt stress.
Service life of the equipment will not be shortened due to harmonic torque.
Product Characteristics
Axpert-Hivert Series Medium Voltage large-capacity drive is a type of medium voltage AC motor speed regulation drive. Our drive adopts the
advanced technology of series connection and wave overlap of the power cell, space vector sine wave PWM control. It also incorporates full
English operating interface and high-performance IGBT based modules, featuring high reliability, superior performance and easy operation. It
can be used for a wide range of applications such as regulation, energy saving, soft startup and intelligent control of the fan, water pump,
compressors and other similar loads driven by medium voltageAC motor.
Input Current Waveform Output Voltage Waveform Output Current Waveform
06
User-Friendly Touch Screen Interface
Touch screen manages all functions of VFD, and provides user friendly VFD information screen. It is
used to set and display VFD parameters, display the working state of VFD, assist VFD fault diagnosis,
control VFD operation and other functions.
HMI by TPC1061Ti touch screen, uses the advanced Cortex-A8 CPU as core. It is a high brightness TFT LCD
display with resolution 1024 x 600 and 10.2 inch screen. Graphical display makes the interface more rich, fast and
intuitive, user-friendly operation.
Touch screen LCD display has eight windows including:
● Monitoring interface ●Trend curve ● Function parameters
● System parameters ● Fault record ● Other settings
● Power cell status ● Excitation adjust
Advantage: No mechanical rotating component, long operating reliability, and easy upgrading of software.
Flexible Control Options
Local Control: Direct control from the button on cabinet door or
the HMI.This is the main control method.
Remote I/O Control: Realize remote control by connecting to the
remote switch signal via the I/O board.
Host Control: Isolated RS-485 port and adoption of standard
Modbus-RTU communication protocol. Able to connect with host
system like DCS for optimized coordination control.
Five Options of Frequency Set
Direct command from main interface.
Set by analog signal (4...20 mAsignal).
Set by host computer via RS-485 port.
Multi-speed set, suitable for the working conditions in cyclic
change.
In event of closed-loop operation, it will be automatic set by built-in
PID via computation.
AVR (Automatic VoltageAdjustment) Function
According to output voltage feedback, the inverter automatically
adjusts the output voltage to make it free from the influence caused
by the change of grid voltages and loads, and protect the motor from
insulation damage due to long over voltage or core overheating due
to high magnetic flux density.
PID Function
Built-in full digital PID is provided for closed-loop control upon the
users' requirements and for realization of operation under constant
pressure or constant fluid flux. PID parameters can be adjusted
online.
Current Limiting Function
In event the output current of the inverter exceeds the preset value, the
inverter will automatically limit the current output to avoid overcurrent
protection incurred during acceleration or deceleration or due to
sudden change of the loads, thus to minimize the stop times of the
machine.
Self-diagnosis Function
Axpert-Hivert MVD is provided with complete self-diagnosis capability
to monitor the system status online. In event of any fault, the inverter will
be automatically activated to take protective actions and save the time,
cause and location of the fault. This will help the maintenance
personnel find the cause and eliminate the fault quickly.
Instantaneous Power Loss Tracing Function
In event of instantaneous electric grid power loss, the inverter controls
the motor to be under power-generating status and keep decelerated
operation. If the electric grid resumes to normal, the inverter will
immediately return to original operating status. The keeping time is
1000 msec and typical value of the fan load is 3 sec.
Other Characteristics
Highly efficient, with the system total efficiency up to 95% or over.
Redundant control power is simultaneously supplied by 415 VAC.
Wide range of input voltage.
Fast braking function.
Resonance frequency avoidance.
Customized design available upon the user's request.
07
1. One inverter drives one motor
When the inverter exits the operation, it may switch the motor into the
grid via the by-pass circuit, thus to ensure the continuity of the
production activity. If vacuum contactor is selected for the switch K1,
K2 and K3, the switching operation may be completed automatically.
Application Program
2. One inverter switches between two motors
To cut your investment, you may select this method where one
inverter needs to switch between two motors, i.e. one in service
and one on standby.
MV Busbar
DL
MV Cabinet
K1
K2
K3
Optional
By-pass Cabinet
D
AXPERT
HIVERT
MV Inverter
MV Busbar
DL
MV Cabinet
K1 K2 By-pass Cabinet
AXPERT
HIVERT
MV Inverter
DL1 DL2
D1 D2
Product Parameters
1. Technical Parameters
6.6 kV Series
3.3 kV Series 11 kV Series
Rated input voltage 3.3 kV (-20%...+15%) 4.16 kV (-20%...+15%) 6.6 kV (-20%...+15%) 11 kV (-20%...+15%)
Input frequency 50 Hz / 60 Hz (±10%)
Modulation technology Space vector PWM control
Control power 415 VAC, <30 kVA depending upon the power rating
Input power factor >0.96
Efficiency (including transformer) >96%, under rated load, for VFD >98%
Output frequency range 0...80 Hz
Output frequency resolution 0.01 Hz / 0.002 Hz
Overload capacity 120% for 2 minute
Analog input 3-channel, 4...20 mA / 2...10 V
Analog output 4-channel, 4...20 mA
Communication with host Isolating RS-485 port, MODBUS RTU protocol, other protocol optional
Accel and Decel time 5...1600 s
Digital Input and output Input : 14 / Output : 22 (All potential free contacts)
Operating environmental temperature -5...45 ºC, derate above 45 ºC, consult Amtech for derating
Storage/transportation temperature -40...70 ºC
Cooling mode Forced air cooling
Environmental humidity 95% or below, no condensation
Installation elevation 1000 m, derate above 1000 m, consult Amtech for derating
Protection level IP30, consult Amtech for higher protection
Cabinet colors RAL 7032, consult Amtech for customization
4.16 kV Series
08
2. Model and Identification
3. Product Series
Rated output voltage (kV), e.g. 3.3, 4.16, 6.6, 11
09
3.3 kV Series
4.16 kV Series
6.6 kV Series
11 kV Series
Ÿ Cabinet type that ends with "S" means this cabinet is "front-side service zone only" cabinet; all other cabinets are "double-side service zone" cabinets.
Ÿ # Contact Amtech for details.
/
For example,Axpert-Hivert-T6.6 / 130 represents an inverter with 6.6 kV voltage and rated output current up to 130A(Capacity: 1490 kVA),
used for driving the synchronous motor with rated power up to 1200 kW. Axpert-Hivert-Y11 / 040 represents an inverter with 11 kV voltage
and rated output current up to 40A(Capacity: 775 kVA), used for driving the asynchronous motor with rated power up to 640 kW.
Axpert-Hivert
Rated output current (A), e.g. 077, 130
Name of Amtech Axpert-Hivert Series Medium Voltage Drive
Applicable motor type, Y: Asynchronous, T: Synchronous
Axpert-Hivert-Y(T)3.3/ 31 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800
Rated O/P Current (A) 31 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800
Inverter Capacity (kVA) 180 230 275 350 440 550 750 880 990 1100 1260 1390 1575 1740 1950 2300 2430 2860 3150 3430 3775 4300 4575
Applicable Motor (kW) 150 180 220 275 350 440 590 700 790 880 1000 1100 1250 1400 1600 1825 2000 2280 2500 2750 3000 3500 3600
Weight (kg) 3100 3500 3700 3950 3800 4000 4100 3660 3780 3950 4120 4340 5530 5740 6040 6390 7000 7400 7600 7800 10500 12500 14500
Type of Cabinet LD1 LD2S LD3S LD4 LD5 LD6
Axpert-Hivert-Y(T)4.16/ 31 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800
Rated O/P Current (A) 31 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800
Inverter Capacity (kVA) 225 290 350 440 555 700 940 1110 1250 1390 1590 1750 1990 2200 2450 2890 3075 3600 3975 4330 4755 5400 5775
Applicable Motor (kW) 180 240 280 350 450 550 750 900 1000 1100 1250 1400 1600 1800 2000 2300 2500 2900 3200 3500 3800 4300 4600
Weight (kg) 3200 3600 3800 4000 3900 4100 4300 4070 4230 4450 4660 4865 6400 6660 6920 7280 8800 9000 9300 9800 11000 12500 15000
Type of Cabinet LJ1 LJ2 LJ3S LJ4 LJ5 LJ6
Axpert-Hivert-Y(T)6.6/ 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800
Rated O/P Current (A) 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800
Inverter Capacity (kVA) 460 550 700 880 1100 1490 1760 1975 2200 2500 2775 3150 3475 3890 4575 4860 5720 6290 6860 7550 8575 9150
Applicable Motor (kW) 365 440 550 700 880 1200 1400 1600 1800 2000 2250 2500 2800 3100 3600 3900 4550 5000 5500 6000 6900 7400
Weight (kg) 4800 5100 5400 4300 4800 5300 5920 6230 6530 6880 7270 9220 9570 10070 10670 14700 15200 15800 16000 20500 22500 24500
Type of Cabinet LC1S LC2S LC3S LC4 LC5 LC6
Axpert-Hivert-Y(T)11/ 31 40 48 61 77 96 104 115 130 154 165 192 205 243 275 304 325 364 400 462 500 600 800
Rated O/P Current (A) 31 40 48 61 77 96 104 115 130 154 165 192 205 243 275 304 325 364 400 462 500 600 800
Inverter Capacity (kVA) 600 775 920 1175 1475 1830 1975 2200 2475 2940 3150 3660 3900 4630 5240 5800 6200 6950 7630 8800 9530 11450 15250
Applicable Motor (kW) 470 640 730 930 1200 1450 1550 1750 2000 2400 2500 2950 3150 3700 4000 4650 5000 5550 6100 7050 7600 9200 11000
Weight (kg)
3930
4000
4160
4200
4475
4550
4830
4700
4900
4970
5300
5410
5530
5710
5830
5880
6120
6170
8510
7580
8640
7525
9050
7965
9560
8280
10160
8795
13020 13620 14320 15620 15720 25400 27400 29400 45400
Type of Cabinet
LB1S
LB1
LB2S
LB2
LB3S
LB3
LB4 LB5 LB6
Note :
1. The by-pass cabinet and switching cabinet are optional.
2. Size of manual by-pass cabinet, manual switching cabinet and automatic switching cabinet: 1000 wide, 2100 high in minimum, or as high
as the inverter if the inverter is over 2100 high; the depth is the same as the inverter cabinet.
3. Size of the automatic by-pass cabinet: 2x1000 wide, 2100 high in minimum, or as high as the inverter if the inverter is 2100 high or higher
the depth is the same as the inverter cabinet.
4. Dimensions & specifications are subject to change without notice.
MVD Dimension Details
Fig.1 Cabinet Outline with Seperate Transformer Cabinet Fig.2 Cabinet Outline with Integrated Transformer Cabinet
10
CABINET
CODE
A
(Total
Width)
B
(Transformer
Cabinet
Width)
C
(Power Cell
Cabinet
Width)
D
(Depth)
E
(Cabinet
Height )
F
(Fan
Height)
3.3 kV Series
LD1 2150 * 2150 1400 2400 450
LD2S 4000 2000 2000 1200 2200 450
LD3S 4050 2000 2050 1200 2300 450
LD4 4350 2150 2200 1400 2400 450
LD5 5350 2400 2950 1400 2400 450
LD6 8050 1600 2400 450
4.16 kV Series
LJ1 2150 * 2150 1400 2400 450
LJ2 2150 * 2150 1600 2400 450
LJ3S 4050 2000 2050 1200 2300 450
LJ4 5050 2400 2650 1400 2400 450
LJ5 6200 2400 3800 1400 2400 450
LJ6 6900 2400 4500 1600 2400 450
CABINET
CODE
A
(Total
Width)
B
(Transformer
Cabinet
Width)
C
(Power Cell
Cabinet
Width)
D
(Depth)
E
(Cabinet
Height )
F
(Fan
Height)
6.6 kV Series
LC1S 3500 1500 2000 1200 1900 450
LC2S 4200 2000 2200 1200 2200 450
LC3S 4550 2000 2550 1200 2300 450
LC4 6000 2400 3600 1400 2400 450
LC5 7800 2700 5100 1400 2400 450
LC6 8900 2800 6100 1600 2400 450
11 kV Series
LB1S
LB1
4300
4000
1700
2000
2600
2000
1200
1400
1900
2050
450
450
LB2S
LB2
4800
4300
2100
2150
2700
2150
1200
1600
2200
2250
450
450
LB3S
LB3
5000
4750
#
2150
#
2600
1200
1600
2200
2250
450
450
LB4 7550 2700 4850 1600 2400 450
LB5 10050 2800 7250 1600 2800 450
LB6 13950 # # 1600 2600 450
All dimensions are in mm.
* Transformer is included in power cell cabinet (Refer Fig.2)
and total width of cabinet is equal to width of power cell cabinet.
# Contact Amtech for details.
# #
Application Industries and Fields
Axpert-Hivert Series Medium Voltage Drive is a perfect solution for soft start, speed adjusting, energy
saving and intelligent control of high voltage AC motors (including synchronous and asynchronous motors).
Typical application industries include :
   
Forced draft fan Slurry pump Primary fan Compressor
  
Water pumping energy storage pump Induced draft fan Coal mill
  
Secondary fan Condensate pump Powder exhaust fan
Thermal power, Hydro power, Garbage biomass
  
Pipeline transportation pump Water injection pump Feed water pump
   
Submerged pump Brine pump Compressor Pressure blower
 Feed water pump for offshore oil platform
Petroleum, Petrochemical, Natural gas
   
Descaling pump Mud pump Slurry pump Clean water pump
   
Feeding pump Stirring pump Kiln transmission Ventilation fan
 
Drainage pump Medium pump
Coal mines & minerals
  
Blast furnace blower Primary dust removal blower Induced draft fan
   
Compressor Kneader Compressing blower Forced draft fan
  
Secondary dust removal blower Water-delivery pump Descaling pump
 Feed water pump
Steel & nonferrous metallurgy
  
Kiln draft fan Kiln fan Rotary kiln transmission
  
Coal mill Dust removal fan Cooling fan
Cement & building materials
   
Pressure blower Induced draft fan Forced draft fan Pressure pump
   
Sewage pump Cleaning water pump Lifting pump Reclaimed water pump
Municipal (heat supply, water supply, sewage etc.)
   
Gas blower Pressure pump Compressor Axial flow pump
 
Soft water pump Water-delivery pump
Light industry, chemical industry
 
Test stand Wind tunnel
Military industry & others
11
OUR OTHER OFFERINGS
We provide complete motor
control system solutions or
individual system components
to address industry specific
requirements and optimize
your process.
Our solutions are simple,
compatible and environment
friendly, resulting in efficient
production, cost optimization
a n d m i n i m i z i n g h u m a n
intervention. It even leads to
energy conservation especially
in typical Fan, Blower
applications.
Flagship Solutions
 Axpert-Eazy+ Series VFD
 Axpert-VT240S Series VFD
 A x p e r t - H i v e r t S e r i e s
Medium Voltage Drive
 Axpert-Opti torque Series
Soft Starter
 Axpert-Eazy HF Series
High Frequency Drive
Applications
 Fans, Blowers, Pumps
 Compressors, Centrifuges
 Agitators & Conveyors
 Oil & Gas
 Mining
Amtech's Power Quality
Solution offers you the synergy
of multiple benefits - energy
conservation, enhanced
operational efficiency and
reliability through a range of
products and services.
Products
 Axpert-i-Sine Series Active
Front end Converter
 Axpert-i-Sine Series Active
Harmonic Filter (AHF)
 Axpert-i-Sine Series Active
Static VAR Compensator
(STATCON)
 Static Harmonic Converter
 Harmonic Reactor
 Sinus Filter
 EMI/RFI Filter
Services
 Harmonic Audit and
Solutions to comply with
IEEE-519 standard
 System design,
optimization & pay-back
analysis
 Consultancy for Power
Quality Improvement
 Training on Power Quality
Management
 Energy Audit and solutions
by experienced BEE
certified professionals
MOTOR CONTROL AUTOMATION POWER QUALITY INDUSTRIAL ELECTRONICS
“DRIVE FOR SUCCESS”
“AUTOMATION.
MADE EASY”
“ONE STOP SOLUTION
TO QUALITY POWER”
“YOUR TECHNOLOGY
PARTNER”
"Automation Made Easy" is our
philosophy to simplify the
increasing complexity of
modern production systems
through our Amtech-Jetter
PROCESS PLC technology
platform.
Our 30 years experience in
Machine, Line, Plant and
Networking Automation has
helped us to find the best
s o l u t i o n i n t e r m s o f
functionality, sustainability and
efficiency.
Flagship Solutions
Jet Control series PLC
C o n t r o l l e r s , E x p a n s i o n
Modules, Jet view Soft
SCADA, HMIs, Jet Move
series Servo and Axes Control
System.
Applications
 Paper Machine Automation
 Textiles Manufacturing
 Packaging
 Winder Machine
 Crane & Material Handling
Equipment
 CNC Machines
 Semiconductor Assembly
Line
 Retrofit solutions
Amtech’s Power Electronics
Engineering Services offer
technology solutions to
i n d e p e n d e n t R & D l a b s ,
industrial segments like
T r a c t i o n , O i l & G a s ,
Automotive and Renewable
Energy for wind to reduce your
time to market.
Products
 Traction Drive
 High Voltage Power Supply
 Battery back-up drive &
systems for critical loads
 Wind Power Converter
 Digital Heater controller
 Batter charger
 Drive Train
Services
 Power Electronics
Engineering Services
 Customized solutions for
industry specific
applications
 Solutions for Oil, Gas &
Mining
 Power Electronics product
development & testing
 Product verification &
validation
 Retrofit Solutions
E-6, GIDC Electronics Zone, Gandhinagar - 382028, Gujarat, India.
Phone: +91-79-23289101, 23289102, 23289103 | Fax: +91-79-23289111
Email: info@amtechelectronics.com | Website: www.amtechelectronics.com
Specifications in this catalog are subject to change without notice
CAT.NO.:AEIL/MVD/07-20

More Related Content

What's hot

sub-station training report
sub-station training reportsub-station training report
sub-station training reportsitesh95074
 
Ahmed zahran power electronics projects portfolio
Ahmed zahran power electronics projects portfolioAhmed zahran power electronics projects portfolio
Ahmed zahran power electronics projects portfolioahmed_zahran
 
Practical handbook-for-relay-protection-engineers
Practical handbook-for-relay-protection-engineersPractical handbook-for-relay-protection-engineers
Practical handbook-for-relay-protection-engineersSARAVANAN A
 
Research Inventy : International Journal of Engineering and Science is publis...
Research Inventy : International Journal of Engineering and Science is publis...Research Inventy : International Journal of Engineering and Science is publis...
Research Inventy : International Journal of Engineering and Science is publis...researchinventy
 
power house training seminar
power house training seminarpower house training seminar
power house training seminarParas kumar
 
Arm cortex ( lpc 2148 ) based motor speed control
Arm cortex ( lpc 2148 ) based motor speed control Arm cortex ( lpc 2148 ) based motor speed control
Arm cortex ( lpc 2148 ) based motor speed control Uday Wankar
 
Speed control of four quadrant d nav
Speed control of four quadrant d navSpeed control of four quadrant d nav
Speed control of four quadrant d navNavjyoti Sharma
 
TENSE Elektrik-Elektronik Introducing Presentation
TENSE Elektrik-Elektronik Introducing PresentationTENSE Elektrik-Elektronik Introducing Presentation
TENSE Elektrik-Elektronik Introducing PresentationEmrullahAKGN
 
33/11 kV substation (u.p.p.c.l.)
33/11 kV substation (u.p.p.c.l.)33/11 kV substation (u.p.p.c.l.)
33/11 kV substation (u.p.p.c.l.)Prateek Agarwal
 
Advanced motion controls avb250a060
Advanced motion controls avb250a060Advanced motion controls avb250a060
Advanced motion controls avb250a060Electromate
 
Vacon nxl-brochure-bc00089 d-en
Vacon nxl-brochure-bc00089 d-enVacon nxl-brochure-bc00089 d-en
Vacon nxl-brochure-bc00089 d-enhongkiworld
 
industrial Training report in PTCUL Substation dehradun
industrial Training report in PTCUL Substation dehradunindustrial Training report in PTCUL Substation dehradun
industrial Training report in PTCUL Substation dehradunsurendra rawat
 
An9611
An9611An9611
An9611anfeco
 
Advanced motion controls avb200a100
Advanced motion controls avb200a100Advanced motion controls avb200a100
Advanced motion controls avb200a100Electromate
 
Advanced motion controls sr30a40ac
Advanced motion controls sr30a40acAdvanced motion controls sr30a40ac
Advanced motion controls sr30a40acElectromate
 
Advanced motion controls ab100c200
Advanced motion controls ab100c200Advanced motion controls ab100c200
Advanced motion controls ab100c200Electromate
 

What's hot (20)

Scada
ScadaScada
Scada
 
sub-station training report
sub-station training reportsub-station training report
sub-station training report
 
Ahmed zahran power electronics projects portfolio
Ahmed zahran power electronics projects portfolioAhmed zahran power electronics projects portfolio
Ahmed zahran power electronics projects portfolio
 
Practical handbook-for-relay-protection-engineers
Practical handbook-for-relay-protection-engineersPractical handbook-for-relay-protection-engineers
Practical handbook-for-relay-protection-engineers
 
Research Inventy : International Journal of Engineering and Science is publis...
Research Inventy : International Journal of Engineering and Science is publis...Research Inventy : International Journal of Engineering and Science is publis...
Research Inventy : International Journal of Engineering and Science is publis...
 
C2000 m en_20120201
C2000 m en_20120201C2000 m en_20120201
C2000 m en_20120201
 
power house training seminar
power house training seminarpower house training seminar
power house training seminar
 
Arm cortex ( lpc 2148 ) based motor speed control
Arm cortex ( lpc 2148 ) based motor speed control Arm cortex ( lpc 2148 ) based motor speed control
Arm cortex ( lpc 2148 ) based motor speed control
 
400 Kv Soja
400 Kv Soja400 Kv Soja
400 Kv Soja
 
03 TOTAL REPORT
03 TOTAL REPORT03 TOTAL REPORT
03 TOTAL REPORT
 
Speed control of four quadrant d nav
Speed control of four quadrant d navSpeed control of four quadrant d nav
Speed control of four quadrant d nav
 
TENSE Elektrik-Elektronik Introducing Presentation
TENSE Elektrik-Elektronik Introducing PresentationTENSE Elektrik-Elektronik Introducing Presentation
TENSE Elektrik-Elektronik Introducing Presentation
 
33/11 kV substation (u.p.p.c.l.)
33/11 kV substation (u.p.p.c.l.)33/11 kV substation (u.p.p.c.l.)
33/11 kV substation (u.p.p.c.l.)
 
Advanced motion controls avb250a060
Advanced motion controls avb250a060Advanced motion controls avb250a060
Advanced motion controls avb250a060
 
Vacon nxl-brochure-bc00089 d-en
Vacon nxl-brochure-bc00089 d-enVacon nxl-brochure-bc00089 d-en
Vacon nxl-brochure-bc00089 d-en
 
industrial Training report in PTCUL Substation dehradun
industrial Training report in PTCUL Substation dehradunindustrial Training report in PTCUL Substation dehradun
industrial Training report in PTCUL Substation dehradun
 
An9611
An9611An9611
An9611
 
Advanced motion controls avb200a100
Advanced motion controls avb200a100Advanced motion controls avb200a100
Advanced motion controls avb200a100
 
Advanced motion controls sr30a40ac
Advanced motion controls sr30a40acAdvanced motion controls sr30a40ac
Advanced motion controls sr30a40ac
 
Advanced motion controls ab100c200
Advanced motion controls ab100c200Advanced motion controls ab100c200
Advanced motion controls ab100c200
 

Similar to Axpert hivert series mv drive

Weg automation-drives-and-controls-usa804-brochure-english
Weg automation-drives-and-controls-usa804-brochure-englishWeg automation-drives-and-controls-usa804-brochure-english
Weg automation-drives-and-controls-usa804-brochure-englishDaniel García
 
Original Power Suply IC TOP227YN TOP227Y TOP227 227 TO-220 NewOriginal Power ...
Original Power Suply IC TOP227YN TOP227Y TOP227 227 TO-220 NewOriginal Power ...Original Power Suply IC TOP227YN TOP227Y TOP227 227 TO-220 NewOriginal Power ...
Original Power Suply IC TOP227YN TOP227Y TOP227 227 TO-220 NewOriginal Power ...AUTHELECTRONIC
 
Cockpit White Box
Cockpit White BoxCockpit White Box
Cockpit White Boxncct
 
Design of embedded based three phase preventor and selector system for indust...
Design of embedded based three phase preventor and selector system for indust...Design of embedded based three phase preventor and selector system for indust...
Design of embedded based three phase preventor and selector system for indust...IAEME Publication
 
IRJET- Implementation of Grid Tied Inverter in Solar Panel
IRJET-  	  Implementation of Grid Tied Inverter in Solar PanelIRJET-  	  Implementation of Grid Tied Inverter in Solar Panel
IRJET- Implementation of Grid Tied Inverter in Solar PanelIRJET Journal
 
Advanced motion controls 10a8
Advanced motion controls 10a8Advanced motion controls 10a8
Advanced motion controls 10a8Electromate
 
IRJET- Phase Changer Mechanism in Abnormal Conditions for Single Phase Applic...
IRJET- Phase Changer Mechanism in Abnormal Conditions for Single Phase Applic...IRJET- Phase Changer Mechanism in Abnormal Conditions for Single Phase Applic...
IRJET- Phase Changer Mechanism in Abnormal Conditions for Single Phase Applic...IRJET Journal
 
Advanced motion controls sx30a8
Advanced motion controls sx30a8Advanced motion controls sx30a8
Advanced motion controls sx30a8Electromate
 
7SK81 Motor Protection Relay
7SK81 Motor Protection Relay7SK81 Motor Protection Relay
7SK81 Motor Protection Relayashwini reliserv
 
Original Power Supply IC TOP209PN TOP209P TOP209 DIP-7 New Power Intergation
Original Power Supply IC TOP209PN TOP209P TOP209 DIP-7 New Power IntergationOriginal Power Supply IC TOP209PN TOP209P TOP209 DIP-7 New Power Intergation
Original Power Supply IC TOP209PN TOP209P TOP209 DIP-7 New Power IntergationAUTHELECTRONIC
 
Advanced motion controls s60a8
Advanced motion controls s60a8Advanced motion controls s60a8
Advanced motion controls s60a8Electromate
 
Automatic power factor controller by microcontroller
Automatic power factor controller by microcontrollerAutomatic power factor controller by microcontroller
Automatic power factor controller by microcontrollerSanket Shitole
 
Catalog biến tần trung thế Fuji Electric
Catalog biến tần trung thế Fuji ElectricCatalog biến tần trung thế Fuji Electric
Catalog biến tần trung thế Fuji ElectricCTY TNHH HẠO PHƯƠNG
 
Traction system
Traction systemTraction system
Traction systematul giri
 

Similar to Axpert hivert series mv drive (20)

Speed control of motor
Speed control of motorSpeed control of motor
Speed control of motor
 
Weg automation-drives-and-controls-usa804-brochure-english
Weg automation-drives-and-controls-usa804-brochure-englishWeg automation-drives-and-controls-usa804-brochure-english
Weg automation-drives-and-controls-usa804-brochure-english
 
Two Quadrant chopper
Two Quadrant chopperTwo Quadrant chopper
Two Quadrant chopper
 
Original Power Suply IC TOP227YN TOP227Y TOP227 227 TO-220 NewOriginal Power ...
Original Power Suply IC TOP227YN TOP227Y TOP227 227 TO-220 NewOriginal Power ...Original Power Suply IC TOP227YN TOP227Y TOP227 227 TO-220 NewOriginal Power ...
Original Power Suply IC TOP227YN TOP227Y TOP227 227 TO-220 NewOriginal Power ...
 
5 FINAL PROJECT REPORT
5 FINAL PROJECT REPORT5 FINAL PROJECT REPORT
5 FINAL PROJECT REPORT
 
Cockpit White Box
Cockpit White BoxCockpit White Box
Cockpit White Box
 
Design of embedded based three phase preventor and selector system for indust...
Design of embedded based three phase preventor and selector system for indust...Design of embedded based three phase preventor and selector system for indust...
Design of embedded based three phase preventor and selector system for indust...
 
Kikusui dcps pat_denkei
Kikusui dcps pat_denkeiKikusui dcps pat_denkei
Kikusui dcps pat_denkei
 
IRJET- Implementation of Grid Tied Inverter in Solar Panel
IRJET-  	  Implementation of Grid Tied Inverter in Solar PanelIRJET-  	  Implementation of Grid Tied Inverter in Solar Panel
IRJET- Implementation of Grid Tied Inverter in Solar Panel
 
Compact Inverter WJ200 series
Compact Inverter WJ200 seriesCompact Inverter WJ200 series
Compact Inverter WJ200 series
 
Advanced motion controls 10a8
Advanced motion controls 10a8Advanced motion controls 10a8
Advanced motion controls 10a8
 
IRJET- Phase Changer Mechanism in Abnormal Conditions for Single Phase Applic...
IRJET- Phase Changer Mechanism in Abnormal Conditions for Single Phase Applic...IRJET- Phase Changer Mechanism in Abnormal Conditions for Single Phase Applic...
IRJET- Phase Changer Mechanism in Abnormal Conditions for Single Phase Applic...
 
TOP412GN.pdf
TOP412GN.pdfTOP412GN.pdf
TOP412GN.pdf
 
Advanced motion controls sx30a8
Advanced motion controls sx30a8Advanced motion controls sx30a8
Advanced motion controls sx30a8
 
7SK81 Motor Protection Relay
7SK81 Motor Protection Relay7SK81 Motor Protection Relay
7SK81 Motor Protection Relay
 
Original Power Supply IC TOP209PN TOP209P TOP209 DIP-7 New Power Intergation
Original Power Supply IC TOP209PN TOP209P TOP209 DIP-7 New Power IntergationOriginal Power Supply IC TOP209PN TOP209P TOP209 DIP-7 New Power Intergation
Original Power Supply IC TOP209PN TOP209P TOP209 DIP-7 New Power Intergation
 
Advanced motion controls s60a8
Advanced motion controls s60a8Advanced motion controls s60a8
Advanced motion controls s60a8
 
Automatic power factor controller by microcontroller
Automatic power factor controller by microcontrollerAutomatic power factor controller by microcontroller
Automatic power factor controller by microcontroller
 
Catalog biến tần trung thế Fuji Electric
Catalog biến tần trung thế Fuji ElectricCatalog biến tần trung thế Fuji Electric
Catalog biến tần trung thế Fuji Electric
 
Traction system
Traction systemTraction system
Traction system
 

Recently uploaded

Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...lizamodels9
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...lizamodels9
 
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptx
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptxBanana Powder Manufacturing Plant Project Report 2024 Edition.pptx
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptxgeorgebrinton95
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation SlidesKeppelCorporation
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfpollardmorgan
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis UsageNeil Kimberley
 
Call Girls In ⇛⇛Chhatarpur⇚⇚. Brings Offer Delhi Contact Us 8377877756
Call Girls In ⇛⇛Chhatarpur⇚⇚. Brings Offer Delhi Contact Us 8377877756Call Girls In ⇛⇛Chhatarpur⇚⇚. Brings Offer Delhi Contact Us 8377877756
Call Girls In ⇛⇛Chhatarpur⇚⇚. Brings Offer Delhi Contact Us 8377877756dollysharma2066
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewasmakika9823
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 
Tech Startup Growth Hacking 101 - Basics on Growth Marketing
Tech Startup Growth Hacking 101  - Basics on Growth MarketingTech Startup Growth Hacking 101  - Basics on Growth Marketing
Tech Startup Growth Hacking 101 - Basics on Growth MarketingShawn Pang
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Roomdivyansh0kumar0
 
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story… Abridged
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story… AbridgedLean: From Theory to Practice — One City’s (and Library’s) Lean Story… Abridged
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story… AbridgedKaiNexus
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadAyesha Khan
 
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckHajeJanKamps
 
Call Girls In Kishangarh Delhi ❤️8860477959 Good Looking Escorts In 24/7 Delh...
Call Girls In Kishangarh Delhi ❤️8860477959 Good Looking Escorts In 24/7 Delh...Call Girls In Kishangarh Delhi ❤️8860477959 Good Looking Escorts In 24/7 Delh...
Call Girls In Kishangarh Delhi ❤️8860477959 Good Looking Escorts In 24/7 Delh...lizamodels9
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailAriel592675
 
RE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechRE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechNewman George Leech
 
Marketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet CreationsMarketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet Creationsnakalysalcedo61
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst SummitHolger Mueller
 

Recently uploaded (20)

Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
 
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptx
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptxBanana Powder Manufacturing Plant Project Report 2024 Edition.pptx
Banana Powder Manufacturing Plant Project Report 2024 Edition.pptx
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage
 
Call Girls In ⇛⇛Chhatarpur⇚⇚. Brings Offer Delhi Contact Us 8377877756
Call Girls In ⇛⇛Chhatarpur⇚⇚. Brings Offer Delhi Contact Us 8377877756Call Girls In ⇛⇛Chhatarpur⇚⇚. Brings Offer Delhi Contact Us 8377877756
Call Girls In ⇛⇛Chhatarpur⇚⇚. Brings Offer Delhi Contact Us 8377877756
 
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service DewasVip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
Vip Dewas Call Girls #9907093804 Contact Number Escorts Service Dewas
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 
Tech Startup Growth Hacking 101 - Basics on Growth Marketing
Tech Startup Growth Hacking 101  - Basics on Growth MarketingTech Startup Growth Hacking 101  - Basics on Growth Marketing
Tech Startup Growth Hacking 101 - Basics on Growth Marketing
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
 
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story… Abridged
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story… AbridgedLean: From Theory to Practice — One City’s (and Library’s) Lean Story… Abridged
Lean: From Theory to Practice — One City’s (and Library’s) Lean Story… Abridged
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
 
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
 
Call Girls In Kishangarh Delhi ❤️8860477959 Good Looking Escorts In 24/7 Delh...
Call Girls In Kishangarh Delhi ❤️8860477959 Good Looking Escorts In 24/7 Delh...Call Girls In Kishangarh Delhi ❤️8860477959 Good Looking Escorts In 24/7 Delh...
Call Girls In Kishangarh Delhi ❤️8860477959 Good Looking Escorts In 24/7 Delh...
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detail
 
RE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechRE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman Leech
 
Marketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet CreationsMarketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet Creations
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst Summit
 

Axpert hivert series mv drive

  • 1. AXPERT-HIVERT Medium Voltage Drive AN ISO 9001 : 2015 COMPANY
  • 2. 02 Introduction Amtech is one of the leading manufacturers of low voltage AC Drive with world class manufacturing facility and strong in-house R&D. NowAmtech has come up with the state-of-art technology innovated Axpert-Hivert Series Medium Voltage VFD. With the strong technical support system and global network, Amtech is in position to provide highest up time in the industry. Product Structure Transformer Cabinet Isolating Transformer: Secondary multi-winding output provides phase-shifted power supply to the power cell unit. This greatly improves the current waveform on grid side and reduces the harmonic interference of the equipment to power grid. Transformer Cooling Fan: Cooling fan specifically for dry transformer is configured according to different capacity. Power Unit Cabinet Controller: For space vector PWM control, signal acquisition and processing, communication between units via fiber optics for completely electrical isolation. Power Unit: Modular design of power cell units, interchangeable and easy to manufacture, install and repair. Interface board: The core of the new I/O interface board is S7-200 SMART CPU, the module comes standard with Ethernet interface, supports Siemens S7 protocol, TCP/IP protocol and effectively supporting a variety of terminal connections. In addition, the CPU module is integrated with one RS485 interface, able to communicate with the third-party equipment such as the MV drive and touch screen.At the same time, it is equipped with expansion CM01 signal board to realize RS232 / RS485 free communication and support Profibus and Ethernet TCP/IPcommunication protocol. Monitoring HMI: 10 inch touch screen, control system status and monitoring, powerful data control (data logging, diagnostics, and information), user-centric convenience (HD display, high data throughput, user-friendly interface). By-pass Cabinet or Switching Cabinet (Optional) The by-pass cabinet or switching cabinet may employ isolating breaker, vacuum contactor or the combination, depending on the user's working conditions. The function of by-pass cabinet is to put the motor into operation on mains power supply after the inverter exits, so as to ensure the continuity of user's process. The switching cabinet is designed to divert the inverter output to different motors. System Cooling Fan High efficiency fan from world renowned manufacturer. The benefits are large air flow and long service life. Cooling fan Power Unit/control cabinet 11 kV cabinet outline drawing (including manual bypass cabinet) Transformer cabinet Manual bypass cabinet
  • 3. 1. Topology Structure of Main Circuit 3.3 kV Series: , Consisting of 9 power cells; 3 power cells are connected in series to form one phase 3-phase Y-type connection. 4.16 kV Series: Consisting of 12 power cells; 4 power cells are connected in series to form one phase 3-phase Y-type connection. , 6.6 kV Series: , Consisting of 18 power cells; 6 power cells are connected in series to form one phase 3-phase Y-type connection. 11 kV Series: , Consisting of 27 power cells; 9 power cells are connected in series to form one phase 3-phase Y-type connection. Working Principle of Inverter Axpert-Hivert Series Medium Voltage Drive adopts AC-DC-AC direct medium voltage input and output and employs IGBT based power cells in series. The medium voltage output is the result of the overlapping waveforms from each power cell. The Axpert-Hivert Series has very high reliability, thanks to the proven technology of normal voltage inverter. Main Circuit Diagram of Axpert-Hivert Series 6.6 kV Medium Voltage Drive 03
  • 4. 2. Voltage Overlap Diagram Each phase of Axpert-Hivert Series Medium Voltage Drive consists of multiple power cells connected in series, and each power unit is isolated by the secondary winding of isolating transformer. By changing the quantity of units in series, the phase-shifted power supply can easily obtain the output of different voltage level, without being subjected to the restriction of the power devices for their voltage level performance.Assuming that each phase of an inverter rated 6.6 kV consists of 6 power cells and the rated voltage of power cell is 690V, the phase voltage will be 3810 V after connection in series (the corresponding line voltage is 6.6 kV). Each phase of 11 kV Inverter consists of 9 power units, the rated voltage of power unit is 710V, and the working voltage is 710V. 3. Structural Diagram of Power Unit Axpert-Hivert Series Medium Voltage Drive consists of multiple power cells connected in series, and each power unit is powered by the secondary isolating winding of the input isolating transformer. The power unit is of AC-DC-AC structure, equivalent to a low-voltage power source inverter of 3-phase input single-phase output. As power units are fully identical in structure and electrical performance, very easy for maintenance and replacement. The power unit receives the signal via optical fiber and adopts space vector sine wave pulse (PWM) to control the conductivity and disconnection of Q1~Q4 IGBT, outputting single-phase pulse width modulation waveform. Each unit is only possible to have three states of output voltage. When Q1 and Q4 are connected, the output voltage state of L1 and L2 will be 1; when Q2 and Q3 are connected, the output voltage state of L1 and L2 will be -1; and when Q1 and Q2, or Q3 and Q4 are connected, the output voltage state of L1 and L2 will be 0. Inverter Series Quantity of Series Unit Rated Voltage Unit Working Voltage Output Phase Voltage Output Line Voltage Number of Voltage Unto for Each Phase (V) (V) (V) (KV) Level tor Each Phase 3.3 kV 3 690 635 1905 3.3 7 4.16 kV 4 690 600 2402 4.16 9 6.6 kV 6 690 635 3810 6.6 13 11 kV 9 710 710 6390 11 19 Fuse Diode Rectifier DC BUS Inverter R S T L1 L2 Q1 Q2 Q3 Q4 3.3 kV Series 11 kV Series 3300V Line Voltage 1905V Phase Voltage 635 635 635 635 635 635 635 635 635 710 710 710 710 710 710 710 710 710 710 710 710 710 710 710 710 710 710 11000V Line Voltage 6390V Phase Voltage 710 710 710 710 710 710 710 710 710 6.6 kV Series 6600V Line Voltage 3810V Phase Voltage 635 635 635 635 635 635 635 635 635 635 635 635 635 635 635 635 635 635 04
  • 5. 4. External Control System Diagram 05 I/O Interface
  • 6. High-quality Current Input Through phase-shift step down voltage, the secondary winding of isolating transformer on input side provides isolated power source to each power cell. For 3.3 kV, it is equivalent to 18-pulse, (24-pulse for 4.16 kV, 36-pulse for 6.6 kV, 54-pulse for 11 kV) un-controlled rectifying input. This eliminates most of the harmonic current caused by each power cell and greatly reduces the generation of harmonics on grid side. The harmonic voltage and THD caused to electric grid by the inverter meets the most stringent requirements for THD as specified in IEEE Std 519-1992 and GB/T14549-93 (Quality of Electric Energy Supply Harmonics in Public Supply Networks). The inverter does not require installation of any filter, but it can protect the surrounding equipment from harmonic interference. The power factor within normal range of speed regulation is over 0.95, so the power-factor compensation capacitors are not required. Reduces the reactive input and decreases the supply capacity. Perfect Output Performance The units are connected in series and of PWM overlap output. Each phase consists of 6 units for 6.6 kV series inverter, and 9 units for 11 kV series. This results in greatly reduced output of harmonic content, so that the output waveform is nearly perfect sine wave. In comparison with other types of high voltage large-capacity drives, Axpert-Hivert Series MVD has following advantages: No output filter required. Able to drive common high-voltage motor without increasing the motor temperature or decreasing the motor capacity. Motor cable is free of any length restriction. Protective insulation of motor is free from the damage of dv/dt stress. Service life of the equipment will not be shortened due to harmonic torque. Product Characteristics Axpert-Hivert Series Medium Voltage large-capacity drive is a type of medium voltage AC motor speed regulation drive. Our drive adopts the advanced technology of series connection and wave overlap of the power cell, space vector sine wave PWM control. It also incorporates full English operating interface and high-performance IGBT based modules, featuring high reliability, superior performance and easy operation. It can be used for a wide range of applications such as regulation, energy saving, soft startup and intelligent control of the fan, water pump, compressors and other similar loads driven by medium voltageAC motor. Input Current Waveform Output Voltage Waveform Output Current Waveform 06
  • 7. User-Friendly Touch Screen Interface Touch screen manages all functions of VFD, and provides user friendly VFD information screen. It is used to set and display VFD parameters, display the working state of VFD, assist VFD fault diagnosis, control VFD operation and other functions. HMI by TPC1061Ti touch screen, uses the advanced Cortex-A8 CPU as core. It is a high brightness TFT LCD display with resolution 1024 x 600 and 10.2 inch screen. Graphical display makes the interface more rich, fast and intuitive, user-friendly operation. Touch screen LCD display has eight windows including: ● Monitoring interface ●Trend curve ● Function parameters ● System parameters ● Fault record ● Other settings ● Power cell status ● Excitation adjust Advantage: No mechanical rotating component, long operating reliability, and easy upgrading of software. Flexible Control Options Local Control: Direct control from the button on cabinet door or the HMI.This is the main control method. Remote I/O Control: Realize remote control by connecting to the remote switch signal via the I/O board. Host Control: Isolated RS-485 port and adoption of standard Modbus-RTU communication protocol. Able to connect with host system like DCS for optimized coordination control. Five Options of Frequency Set Direct command from main interface. Set by analog signal (4...20 mAsignal). Set by host computer via RS-485 port. Multi-speed set, suitable for the working conditions in cyclic change. In event of closed-loop operation, it will be automatic set by built-in PID via computation. AVR (Automatic VoltageAdjustment) Function According to output voltage feedback, the inverter automatically adjusts the output voltage to make it free from the influence caused by the change of grid voltages and loads, and protect the motor from insulation damage due to long over voltage or core overheating due to high magnetic flux density. PID Function Built-in full digital PID is provided for closed-loop control upon the users' requirements and for realization of operation under constant pressure or constant fluid flux. PID parameters can be adjusted online. Current Limiting Function In event the output current of the inverter exceeds the preset value, the inverter will automatically limit the current output to avoid overcurrent protection incurred during acceleration or deceleration or due to sudden change of the loads, thus to minimize the stop times of the machine. Self-diagnosis Function Axpert-Hivert MVD is provided with complete self-diagnosis capability to monitor the system status online. In event of any fault, the inverter will be automatically activated to take protective actions and save the time, cause and location of the fault. This will help the maintenance personnel find the cause and eliminate the fault quickly. Instantaneous Power Loss Tracing Function In event of instantaneous electric grid power loss, the inverter controls the motor to be under power-generating status and keep decelerated operation. If the electric grid resumes to normal, the inverter will immediately return to original operating status. The keeping time is 1000 msec and typical value of the fan load is 3 sec. Other Characteristics Highly efficient, with the system total efficiency up to 95% or over. Redundant control power is simultaneously supplied by 415 VAC. Wide range of input voltage. Fast braking function. Resonance frequency avoidance. Customized design available upon the user's request. 07
  • 8. 1. One inverter drives one motor When the inverter exits the operation, it may switch the motor into the grid via the by-pass circuit, thus to ensure the continuity of the production activity. If vacuum contactor is selected for the switch K1, K2 and K3, the switching operation may be completed automatically. Application Program 2. One inverter switches between two motors To cut your investment, you may select this method where one inverter needs to switch between two motors, i.e. one in service and one on standby. MV Busbar DL MV Cabinet K1 K2 K3 Optional By-pass Cabinet D AXPERT HIVERT MV Inverter MV Busbar DL MV Cabinet K1 K2 By-pass Cabinet AXPERT HIVERT MV Inverter DL1 DL2 D1 D2 Product Parameters 1. Technical Parameters 6.6 kV Series 3.3 kV Series 11 kV Series Rated input voltage 3.3 kV (-20%...+15%) 4.16 kV (-20%...+15%) 6.6 kV (-20%...+15%) 11 kV (-20%...+15%) Input frequency 50 Hz / 60 Hz (±10%) Modulation technology Space vector PWM control Control power 415 VAC, <30 kVA depending upon the power rating Input power factor >0.96 Efficiency (including transformer) >96%, under rated load, for VFD >98% Output frequency range 0...80 Hz Output frequency resolution 0.01 Hz / 0.002 Hz Overload capacity 120% for 2 minute Analog input 3-channel, 4...20 mA / 2...10 V Analog output 4-channel, 4...20 mA Communication with host Isolating RS-485 port, MODBUS RTU protocol, other protocol optional Accel and Decel time 5...1600 s Digital Input and output Input : 14 / Output : 22 (All potential free contacts) Operating environmental temperature -5...45 ºC, derate above 45 ºC, consult Amtech for derating Storage/transportation temperature -40...70 ºC Cooling mode Forced air cooling Environmental humidity 95% or below, no condensation Installation elevation 1000 m, derate above 1000 m, consult Amtech for derating Protection level IP30, consult Amtech for higher protection Cabinet colors RAL 7032, consult Amtech for customization 4.16 kV Series 08
  • 9. 2. Model and Identification 3. Product Series Rated output voltage (kV), e.g. 3.3, 4.16, 6.6, 11 09 3.3 kV Series 4.16 kV Series 6.6 kV Series 11 kV Series Ÿ Cabinet type that ends with "S" means this cabinet is "front-side service zone only" cabinet; all other cabinets are "double-side service zone" cabinets. Ÿ # Contact Amtech for details. / For example,Axpert-Hivert-T6.6 / 130 represents an inverter with 6.6 kV voltage and rated output current up to 130A(Capacity: 1490 kVA), used for driving the synchronous motor with rated power up to 1200 kW. Axpert-Hivert-Y11 / 040 represents an inverter with 11 kV voltage and rated output current up to 40A(Capacity: 775 kVA), used for driving the asynchronous motor with rated power up to 640 kW. Axpert-Hivert Rated output current (A), e.g. 077, 130 Name of Amtech Axpert-Hivert Series Medium Voltage Drive Applicable motor type, Y: Asynchronous, T: Synchronous Axpert-Hivert-Y(T)3.3/ 31 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800 Rated O/P Current (A) 31 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800 Inverter Capacity (kVA) 180 230 275 350 440 550 750 880 990 1100 1260 1390 1575 1740 1950 2300 2430 2860 3150 3430 3775 4300 4575 Applicable Motor (kW) 150 180 220 275 350 440 590 700 790 880 1000 1100 1250 1400 1600 1825 2000 2280 2500 2750 3000 3500 3600 Weight (kg) 3100 3500 3700 3950 3800 4000 4100 3660 3780 3950 4120 4340 5530 5740 6040 6390 7000 7400 7600 7800 10500 12500 14500 Type of Cabinet LD1 LD2S LD3S LD4 LD5 LD6 Axpert-Hivert-Y(T)4.16/ 31 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800 Rated O/P Current (A) 31 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800 Inverter Capacity (kVA) 225 290 350 440 555 700 940 1110 1250 1390 1590 1750 1990 2200 2450 2890 3075 3600 3975 4330 4755 5400 5775 Applicable Motor (kW) 180 240 280 350 450 550 750 900 1000 1100 1250 1400 1600 1800 2000 2300 2500 2900 3200 3500 3800 4300 4600 Weight (kg) 3200 3600 3800 4000 3900 4100 4300 4070 4230 4450 4660 4865 6400 6660 6920 7280 8800 9000 9300 9800 11000 12500 15000 Type of Cabinet LJ1 LJ2 LJ3S LJ4 LJ5 LJ6 Axpert-Hivert-Y(T)6.6/ 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800 Rated O/P Current (A) 40 48 61 77 96 130 154 173 192 220 243 275 304 340 400 425 500 550 600 660 750 800 Inverter Capacity (kVA) 460 550 700 880 1100 1490 1760 1975 2200 2500 2775 3150 3475 3890 4575 4860 5720 6290 6860 7550 8575 9150 Applicable Motor (kW) 365 440 550 700 880 1200 1400 1600 1800 2000 2250 2500 2800 3100 3600 3900 4550 5000 5500 6000 6900 7400 Weight (kg) 4800 5100 5400 4300 4800 5300 5920 6230 6530 6880 7270 9220 9570 10070 10670 14700 15200 15800 16000 20500 22500 24500 Type of Cabinet LC1S LC2S LC3S LC4 LC5 LC6 Axpert-Hivert-Y(T)11/ 31 40 48 61 77 96 104 115 130 154 165 192 205 243 275 304 325 364 400 462 500 600 800 Rated O/P Current (A) 31 40 48 61 77 96 104 115 130 154 165 192 205 243 275 304 325 364 400 462 500 600 800 Inverter Capacity (kVA) 600 775 920 1175 1475 1830 1975 2200 2475 2940 3150 3660 3900 4630 5240 5800 6200 6950 7630 8800 9530 11450 15250 Applicable Motor (kW) 470 640 730 930 1200 1450 1550 1750 2000 2400 2500 2950 3150 3700 4000 4650 5000 5550 6100 7050 7600 9200 11000 Weight (kg) 3930 4000 4160 4200 4475 4550 4830 4700 4900 4970 5300 5410 5530 5710 5830 5880 6120 6170 8510 7580 8640 7525 9050 7965 9560 8280 10160 8795 13020 13620 14320 15620 15720 25400 27400 29400 45400 Type of Cabinet LB1S LB1 LB2S LB2 LB3S LB3 LB4 LB5 LB6
  • 10. Note : 1. The by-pass cabinet and switching cabinet are optional. 2. Size of manual by-pass cabinet, manual switching cabinet and automatic switching cabinet: 1000 wide, 2100 high in minimum, or as high as the inverter if the inverter is over 2100 high; the depth is the same as the inverter cabinet. 3. Size of the automatic by-pass cabinet: 2x1000 wide, 2100 high in minimum, or as high as the inverter if the inverter is 2100 high or higher the depth is the same as the inverter cabinet. 4. Dimensions & specifications are subject to change without notice. MVD Dimension Details Fig.1 Cabinet Outline with Seperate Transformer Cabinet Fig.2 Cabinet Outline with Integrated Transformer Cabinet 10 CABINET CODE A (Total Width) B (Transformer Cabinet Width) C (Power Cell Cabinet Width) D (Depth) E (Cabinet Height ) F (Fan Height) 3.3 kV Series LD1 2150 * 2150 1400 2400 450 LD2S 4000 2000 2000 1200 2200 450 LD3S 4050 2000 2050 1200 2300 450 LD4 4350 2150 2200 1400 2400 450 LD5 5350 2400 2950 1400 2400 450 LD6 8050 1600 2400 450 4.16 kV Series LJ1 2150 * 2150 1400 2400 450 LJ2 2150 * 2150 1600 2400 450 LJ3S 4050 2000 2050 1200 2300 450 LJ4 5050 2400 2650 1400 2400 450 LJ5 6200 2400 3800 1400 2400 450 LJ6 6900 2400 4500 1600 2400 450 CABINET CODE A (Total Width) B (Transformer Cabinet Width) C (Power Cell Cabinet Width) D (Depth) E (Cabinet Height ) F (Fan Height) 6.6 kV Series LC1S 3500 1500 2000 1200 1900 450 LC2S 4200 2000 2200 1200 2200 450 LC3S 4550 2000 2550 1200 2300 450 LC4 6000 2400 3600 1400 2400 450 LC5 7800 2700 5100 1400 2400 450 LC6 8900 2800 6100 1600 2400 450 11 kV Series LB1S LB1 4300 4000 1700 2000 2600 2000 1200 1400 1900 2050 450 450 LB2S LB2 4800 4300 2100 2150 2700 2150 1200 1600 2200 2250 450 450 LB3S LB3 5000 4750 # 2150 # 2600 1200 1600 2200 2250 450 450 LB4 7550 2700 4850 1600 2400 450 LB5 10050 2800 7250 1600 2800 450 LB6 13950 # # 1600 2600 450 All dimensions are in mm. * Transformer is included in power cell cabinet (Refer Fig.2) and total width of cabinet is equal to width of power cell cabinet. # Contact Amtech for details. # #
  • 11. Application Industries and Fields Axpert-Hivert Series Medium Voltage Drive is a perfect solution for soft start, speed adjusting, energy saving and intelligent control of high voltage AC motors (including synchronous and asynchronous motors). Typical application industries include :     Forced draft fan Slurry pump Primary fan Compressor    Water pumping energy storage pump Induced draft fan Coal mill    Secondary fan Condensate pump Powder exhaust fan Thermal power, Hydro power, Garbage biomass    Pipeline transportation pump Water injection pump Feed water pump     Submerged pump Brine pump Compressor Pressure blower  Feed water pump for offshore oil platform Petroleum, Petrochemical, Natural gas     Descaling pump Mud pump Slurry pump Clean water pump     Feeding pump Stirring pump Kiln transmission Ventilation fan   Drainage pump Medium pump Coal mines & minerals    Blast furnace blower Primary dust removal blower Induced draft fan     Compressor Kneader Compressing blower Forced draft fan    Secondary dust removal blower Water-delivery pump Descaling pump  Feed water pump Steel & nonferrous metallurgy    Kiln draft fan Kiln fan Rotary kiln transmission    Coal mill Dust removal fan Cooling fan Cement & building materials     Pressure blower Induced draft fan Forced draft fan Pressure pump     Sewage pump Cleaning water pump Lifting pump Reclaimed water pump Municipal (heat supply, water supply, sewage etc.)     Gas blower Pressure pump Compressor Axial flow pump   Soft water pump Water-delivery pump Light industry, chemical industry   Test stand Wind tunnel Military industry & others 11
  • 12. OUR OTHER OFFERINGS We provide complete motor control system solutions or individual system components to address industry specific requirements and optimize your process. Our solutions are simple, compatible and environment friendly, resulting in efficient production, cost optimization a n d m i n i m i z i n g h u m a n intervention. It even leads to energy conservation especially in typical Fan, Blower applications. Flagship Solutions  Axpert-Eazy+ Series VFD  Axpert-VT240S Series VFD  A x p e r t - H i v e r t S e r i e s Medium Voltage Drive  Axpert-Opti torque Series Soft Starter  Axpert-Eazy HF Series High Frequency Drive Applications  Fans, Blowers, Pumps  Compressors, Centrifuges  Agitators & Conveyors  Oil & Gas  Mining Amtech's Power Quality Solution offers you the synergy of multiple benefits - energy conservation, enhanced operational efficiency and reliability through a range of products and services. Products  Axpert-i-Sine Series Active Front end Converter  Axpert-i-Sine Series Active Harmonic Filter (AHF)  Axpert-i-Sine Series Active Static VAR Compensator (STATCON)  Static Harmonic Converter  Harmonic Reactor  Sinus Filter  EMI/RFI Filter Services  Harmonic Audit and Solutions to comply with IEEE-519 standard  System design, optimization & pay-back analysis  Consultancy for Power Quality Improvement  Training on Power Quality Management  Energy Audit and solutions by experienced BEE certified professionals MOTOR CONTROL AUTOMATION POWER QUALITY INDUSTRIAL ELECTRONICS “DRIVE FOR SUCCESS” “AUTOMATION. MADE EASY” “ONE STOP SOLUTION TO QUALITY POWER” “YOUR TECHNOLOGY PARTNER” "Automation Made Easy" is our philosophy to simplify the increasing complexity of modern production systems through our Amtech-Jetter PROCESS PLC technology platform. Our 30 years experience in Machine, Line, Plant and Networking Automation has helped us to find the best s o l u t i o n i n t e r m s o f functionality, sustainability and efficiency. Flagship Solutions Jet Control series PLC C o n t r o l l e r s , E x p a n s i o n Modules, Jet view Soft SCADA, HMIs, Jet Move series Servo and Axes Control System. Applications  Paper Machine Automation  Textiles Manufacturing  Packaging  Winder Machine  Crane & Material Handling Equipment  CNC Machines  Semiconductor Assembly Line  Retrofit solutions Amtech’s Power Electronics Engineering Services offer technology solutions to i n d e p e n d e n t R & D l a b s , industrial segments like T r a c t i o n , O i l & G a s , Automotive and Renewable Energy for wind to reduce your time to market. Products  Traction Drive  High Voltage Power Supply  Battery back-up drive & systems for critical loads  Wind Power Converter  Digital Heater controller  Batter charger  Drive Train Services  Power Electronics Engineering Services  Customized solutions for industry specific applications  Solutions for Oil, Gas & Mining  Power Electronics product development & testing  Product verification & validation  Retrofit Solutions E-6, GIDC Electronics Zone, Gandhinagar - 382028, Gujarat, India. Phone: +91-79-23289101, 23289102, 23289103 | Fax: +91-79-23289111 Email: info@amtechelectronics.com | Website: www.amtechelectronics.com Specifications in this catalog are subject to change without notice CAT.NO.:AEIL/MVD/07-20