1. ENGR. SAJJAD ALI MANGI (LECTURER)
BE (Civil)-QUEST Nawabshah
ME (Environment)-NED University Karachi
Email: sajjad_ali805@yahoo.com
Lecture No:18
Dated: 7th Jan 2014
2. General Consideration for Water Distribution System
Lecture No:18
Dated: 7th Feb 2014
The water, as it leaves the treatment plant, is of desired quality. But the
standard of this quality is to be maintained when the treated water if flowing
through the network of distribution system.
The water should also be supplied in a way useful to the consumers. For
these reasons, the following general considerations of the planning of
distribution system should be observed in its design:
1. Circulation of water
2. Construction and design
3. Contamination by sewage
4. Earth cushioning (laid under road)
5. Economy
6. Fire demand
7. Gradients
8. Leakages
9. Repairs
10. Safety from Pollution
11. Sanitation
12. Unsafe cross connection.
3. General Consideration for Water Distribution System
Lecture No:18
Dated: 7th Feb 2014
1. Circulation of water: The layout of distribution system should be such that
there is free circulation of water and the number of dead ends should be very
few. Where dead ends are unavoidable, hydrants will be provided to act as
washouts.
2. Construction and design: The construction and design of water distribution
system should be such that sufficient water is available at all times at desired
pressure in all portions of the distribution system.
3. Contamination by sewage: The water pipe should be laid above the sewers at
a vertical distance of about 2 meters and the horizontal distance between the
water pipes and sewer should be at least 3meters .
4. Earth cushioning: The mains which are laid under roads should be provided
with a minimum earth cushioning of 75 to 90 cm height from the top of mains.
5. Economy : The layout and Design of distribution system should be
economical. The cost of distribution system forms a substantial part to the
extent of about 90% of the total cost of the water supply project. Hence water
distribution system should be carefully designed by taking into various factors
such as pumping head, type of pipes, storage requirement, pipe diameters etc
4. General Consideration for Water Distribution System
Lecture No:18
Dated: 7th Feb 2014
6. Fire demand: The distribution system should be so laid that water for fire
demand is available in required quantity at desired pressure at number of
points along it.
7. Gradients: It is not necessary to lay main at constant gradients. But the
gradients of mains should be in general follow the natural contours of ground.
The gradient line should not rise above the hydraulic gradient line which
means that at every point along the mains, there should be a positive pressure
greater than atmospheric pressure.
8. Leakages: The distribution system should be fairly watertight and the loss of
water due to leakages should be brought down to the minimum possible
extent.
9. Repairs: The distribution system should be so laid as to permit easy repairs.
The broken or worn out parts of the equipments for various operations should
be properly replaced.
10. Safety from Pollution: The layout of Distribution system should be such that it
does not contribute to the pollution of water flowing in it.
5. General Consideration for Water Distribution System
Lecture No:18
Dated: 7th Feb 2014
11. Sanitation: The sanitation of area through which the distribution system is
passing should be good that there are no chances for water to be polluted
during repair or replaced of pipe lines.
12. Unsafe cross connection: The distribution system should not have any unsafe
cross connections from which there are chances for contaminated water to
enter it.
6. Methods of Water Distribution System
Lecture No:19
Dated: 10th Feb 2014
Depending upon the topography of the area /country, the following three may be
adopted for distribution of water.
1) Gravity System, 2) Gravity and Pumping System combined, 3) Pumping System
1. Gravity System: In this method, water is conveyed through pipes by gravity
only. The gravity system is the most reliable method of distribution. But it is
useful only when the source of water supply is situated at a higher level than
that of distribution area. As shown in figure A the gravity system with
hydraulic gradient during max. and min. demands. In this case fire, motor
pump may be used to develop high pressure for the fire fighting purpose.
2. Gravity and Pumping System combined: In this system, the treated water is
pumped and stored in an elevated distribution reservoir. The excess water
during low consumption remain in the elevated reservoir and it is supplied
during the peak period. The pumps are usually worked at constant rate and
this rate of pumping is so adjusted that the excess quantity of water stored in
reservoir during low consumption is nearly equal to the extra demand of
water during peak period. As shown figure B it shows the combined gravity
and pumping system with hydraulic gradient during max. and min. demands.
7. Methods of Water Distribution System
Lecture No:19
Dated: 10th Feb 2014
This method of distribution is usually applicable in most of the cases and it has the
following advantages;
i) in case of a fire, motor pumps can be used to develop high pressure or fire
demand can directly be satisfied from pump house after closing the inlet valve
for elevated reservoir.
ii) In this method, the pumps are generally worked at uniform rate.
iii) This method is economical
iv) This method is fairly reliable in the sense that some quantity of water is
available from elevated reservoir even during breakdown of pumps.
3. Pumping System: In this system, water is directly pumped into the mains
leading to the consumers. The number of pumps required in this system will
depend on the demand of water. As figure shows C the pumping system with
hydraulic gradients during max. and min. demands.
8. Service Reservoir
Lecture No:20
Dated: 11th Feb 2014
The service or distribution reservoir are generally provided in the distribution
system to store clear treated water before it is dispatched to the consumers.
These may be constructed of brick masonry, Stone masonry, Reinforced
cement concrete (RCC), etc
Purposes:
Following are the purposes served by the service or distribution reservoir:
1. If pumps are used, the provision of these reservoir make it possible to run
pumps at uniform rate.
2. In case of gravity system of supply, the provision of these reservoirs will result
in main of smaller diameters.
3. They furnish the facility of storage of water for meeting fluctuating hourly
demand of water.
4. They maintain constant pressure in the mains. The pressure in mains, without
service reservoirs, will fall as the demand of water will increase.
5. They make the design and construction of treatment units and distribution
system economical.
6. They serve as storage for emergencies such as breakdown of pumps, bursting
of mains, heavy fire demand, interruption in power supply, temporary floods,
etc.
9. Classification of Service Reservoir
Lecture No:21
Dated: 12th Feb 2014
According to situation with respect to ground, the service reservoirs are
classified in the following three types,
(1) Surface Reservoir,
(2) Elevated Reservoir,
(3) Stand Pipes,
Surface Reservoir: These are also known as ground or non-elevated reservoir.
They are constructed at ground level and are mainly used to store water. It is
usual practice to construct a surface reservoir in two compartments so that
one can be used while the other is being cleaned or repaired.
The two compartments are connected with each other by control valves.
Due to storage of water, silting will take place to some extent and it can be
removed by occasional cleaning through the washout pipes which are placed
at the bottom of the reservoir.
The surface reservoir are usually located at high points in the distribution
system. In the gravity system of supply, water can directly be sent to the
distribution system from the surface reservoir. In the combined gravity and
pumping system, filtered water is first stored in the surface reservoir and it is
then pumped to the elevated reservoir.
10. Classification of Service Reservoir
Lecture No:21
Dated: 12th Feb 2014
Elevated Reservoir: These are also known as overhead tanks and they are
constructed at an elevation from ground level. They may be of any shape
rectangular, circular or elliptical. With the development of science of
structural analysis, it is possible to construct the elevated reservoir in any
shape to suit the architectural requirement of the structure.
The elevated reservoirs are constructed in distributing areas which are not
controlled by gravity system of distribution.
Stand Piped: A stand pipe is a vertical cylindrical tank resting just above the
ground to develop the necessary pressure. The diameter of stand pipe varies
from 10m to 15m and its height varies from 15m to 30m. The stand pipes are
made of RCC, Steel etc.
The stand pipes are usually located on a hill or high ground so as to
successfully utilize its entire capacity.
The stand pipes, like elevated reservoir, are to be provided with inlet pipe,
outlet pipe, overflow pipe, washout pipe and various other accessories for
their efficient working, inspection and maintenance.
11. System of Supply of water
Lecture No:21
Dated: 12th Feb 2014
based on the duration of supply, the following are the two systems of supply
of water.
(1)Continues System, (2) Intermittent System
(1) Continues System: In this system of supply, the water is supplied to the
consumers for 24 hours of the day. This is most ideal system of supply and it
should be adopted as for as possible. The only disadvantage of this system is
that considerable wastage of water occurs if consumers do not possess civic
sense regarding the importance of treated water.
(2) Intermittent System: In this system of supply, the water is supplied during
certain fixed hours of the day only. The usual period is about one to four hours
in the morning and about the same period in the afternoon. The timings of
supply of water may be changed according to the seasons of the year. This
system of supply of water proves to be useful for the following two conditions:
(i) the available pressure is poor and (ii) the quantity of water available is not
sufficient to meet with the various demands of water.
The working of this system is very simple. The distribution area is divided into
several zones and the timings of each zone are so adjusted that good working
pressures are maintained in each zone.
12. Methods of Layout of distribution pipes
Lecture No:22
Dated: 13th Feb 2014
following are the four main methods of laying distribution pipes.
(1) Dead-end Method,
(2) Grid Iron Method,
(3) Circular Method,
(4) Radial Method,
13. Hydraulics of Closed Conduit Flow
• Some time also known as;
- closed conduit flow
- pipe flow
- pressurized flow
2014 11CE 13
Lec: 23, dated: 14th Feb. 2014
Closed Conduit / Pipe
Hydraulics
Engr. Sajjad Ali Mangi
(Lecturer)
Department of Civil Engineering
MUET, SZAB Campus, Khairpur Mir’s
14. Closed Conduit VS Open Channel
Closed Conduit Open Channel
No free surface of water Free water surface
Gravity or pump driven Gravity driven / flow
Cavitation &
other sub-atmospheric-pressure
problems
Waves &
other surface disturbances
Reynolds Number Re Froude Number Fr
2014 11CE 14
Lec: 23, dated: 14th Feb. 2014
15. Concepts – Reynolds Number
• Reynolds number is used to check whether the flow
is laminar or turbulent.
• Reynolds Number is the ratio of inertia force to viscous
force.
V = velocity (ft/sec)
D = pipe diameter (ft)
= density of fluid (lbs/ft3)
= dynamic viscosity of fluid (Pa s, N s/m2)or(lb.ft.sec/ft2 )
= kinematic viscosity (m2/s) or (ft2/sec)
VDVD
Re
2014
11CE 15
Lec: 23, dated: 14th Feb. 2014
Osborne Reynolds (1842–1912),
16. Concepts – Froude Number
• Froud Number is the ratio of inertia force to
gravitational force.
• V = velocity
g = gravitational acceleration
h = depth of water
gh
V
Fr
2014 11CE 16
Lec: 23, dated: 14th Feb. 2014
18. uniform & steady flow
• Uniform flow
The constant characteristics with respect to space
• Steady flow
The constant characteristics with respect to time. Often adopted
when establishing pipe system design parameters (pressure &
flow at certain locations).
• Consider unsteady (transient) phenomena to refine design (pipe
pressure class and thickness)
2014 11CE 18
Lec: 23, dated: 14th Feb. 2014
19. Conservation of Energy
• In pipeline design, most often consider steady
state – flow not varying with time - first
• Steady state (SS) Bernoulli Equation along a
streamline:
h
gg z
Vp
z
Vp 2
2
22
1
2
11
22
2014 11CE 19
Lec: 23, dated: 14th Feb. 2014
Where as;
• Pressure head p/
• Elevation head z
• Velocity head V2/2g
• Piezometric head p/ + z
(hydraulic grade line)
• Total head p/ + z + V2/2g
(energy grade line)
• Head Loss h
20. Head Losses
• There are two types of losses:
1. Friction Loss
Resulting from friction between the fluid and pipe wall
2. Minor Loss
Resulting from pipe entrance, transition, exit, valve and
other in-line structures
2014 11CE 20
Lec: 23, dated: 14th Feb. 2014
21. Friction Loss
• Most useful head loss equation for closed-conduit flow –
Darcy-Weisbach equation
gD
L
f Vhf
2
2
2014 11CE 21
Dimensionless
Friction
coefficient
Pipe
diameter
Pipe
length
Pipe
velocity
Friction head
loss
Gravitational
acceleration
Lec: 23, dated: 14th Feb. 2014
22. Darcy-Weisbach
• Laminar flow (Re<2000)
Turbulent flow in smooth pipes
(Re>4000)
8.0Relog2
1
f
f
Re
64
f
2014 11CE 22
Lec: 23, dated: 14th Feb. 2014
• Turbulent flow in rough pipes
• Transition between turbulent smooth and rough
pipes
D
e
f
log214.1
1
f
D
e
f Re
51.2
7.3
log2
1
28. Empirical Formula of Hazen-Williams formula
2014 11CE 28
Lec: 23, dated: 14th Feb. 2014
Where as;
Hf = Head loss due to friction in fts
L = Length of pipe in fts
C = Frictional coefficient
Q = Discharge in gpm (US gallons) 1US gallon = 3.785 Liters