Application Report
SLVA462–May 2011
Understanding Thermal Dissipation and Design of a
Heatsink
Nikhil Seshasayee ...................................................................................... PMP DCS dc/dc Controllers
ABSTRACT
Power dissipation performance must be well understood prior to integrating devices on a printed-circuit
board (PCB) to ensure that any given device is operated within its defined temperature limits. When a
device is running, it consumes electrical energy that is transformed into heat. Most of the heat is typically
generated by switching devices like MOSFETs, ICs, etc. This application report discusses the thermal
dissipation terminology and how to design a proper heatsink for a given dissipation limit.
Thermal Dissipation
The maximum allowable junction temperature (TJMAX) is one of the key factors that limit the power
dissipation capability of a device. TJMAX is defined by the manufacturer and usually depends on the
reliability of the die used in the manufacturing process.
The typical equation used for calculation of the dissipation is shown in Equation 2:
(1)
Where:
θJA = thermal resistance
TJ = junction temperature
TA = ambient temperature
PD = power dissipation
To discover the maximum power that the device can dissipate, rearrange Equation 2 to:
(2)
With the help of θJA and TJMAX, which are mentioned in the TPS54325 data sheet (SLVS932), PDMAX is
calculated. For example, in the data sheet, θJA is mentioned at 44.5°C/W and TJMAX is given as 125°C.
Using this at different ambient conditions of 25°C and 85°C, one can arrive at the values mentioned in the
data sheet of 2.25 W and 0.9 W, respectively. A parameter called derating factor can be derived from this.
The derating factor is linear, so if the dissipation is 2250 mW for a 100°C rise (from 25°C to 125°C), for
each one degree increase in ambient temperature, the power dissipation rating has to be decreased
2250/100 = 22.50 mW/°C. This parameter is sometimes used for calculation, when the power dissipation
values are unspecified.
In a specific synchronous buck converter application where the input is 5 V and output is 2.5 V at 1 A, 2.5
W is delivered to the load. Note that this is not the power dissipated in the device. When no specific
efficiency curves are in a data sheet for the application, an assumption of the efficiency is to be
considered (90%) to calculate the input power. So, the input power in this case is approximately 2.5/0.9 =
2.75 W, and the power dissipation in the converter is approximately 2.75 – 2.5 = 0.25 W. Some of this
power is dissipated in the inductor, which is external to the chipset. Because the DCR can be known from
the inductor data sheet, the inductor power is:
Pinductor = Iout2 × DCR = 12
× 100 × 10-3
= 100 mW.
The device power dissipation is now 250 mW - 100 mW = 150 mW, and the junction temperature rise
above ambient is calculated using the formula:
1SLVA462–May 2011 Understanding Thermal Dissipation and Design of a Heatsink
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
-
JA JC CS SA
J A
JC CS SA
D
θ = θ + θ + θ
T T
= θ + θ + θ
P
-
- -J A
SA JC CS
D
T T
θ = θ θ
P
www.ti.com
(θJA × PD) + TA = TJ
TJ = 75 × 0.15 + TA = 11.25°C above ambient (75°C/W is the thermal resistance taken as a example)
Consider another example of calculating the dissipation of a logic device SN74ACT240. Based on the
data sheet specifications of the device and actual operating conditions, power dissipated by the logic can
be estimated as per the preceding equations. The device power dissipation consists of two basic
components – the unloaded power dissipation inherent to the device and the load power dissipation,
which is a function of the device loading.
PD(total) = PD(unloaded) + PD(loaded)
Power dissipation in an unloaded logic device can be calculated using the following equations:
PD(unloaded) = VCC × IC
IC = ICC + Iinput + Idynamic
Where:
VCC = supply voltage
ICC = quiescent current
Iinput = total current when inputs are high
Idynamic = power supply current per unit frequency
Iinput = II × NI × DI and Idynamic = Cpd × Vcc
Where:
II = supply current for a high input
NI = number of inputs on high level
DI = duty cycle of inputs at high level
Cpd = power dissipation capacitance
The loading of a logic device can significantly effect the power dissipation. Most of the logic loads appear
to be capacitive, leading to more of dynamic power dissipation. Typical load capacitance is approximately
10 pF to 20 pF. Power dissipation in a loaded logic device can be calculated using the following
equations:
PD(loaded) = VOH × NO × f × CL
Where:
VOH = logic high output voltage
NO = number of outputs loaded with CL
f = output switching frequency
CL = load capacitance per output
Heatsink Design
θJA is actually made up of at least two separate thermal resistances in series. One is the thermal
resistance inside the device package, between the junction and its outside case, called θJC. The other is
the resistance between the case and the ambient, θCA . Because θJC is under the control of the
manufacturer, nothing can be done with it. It is typically low. Another stage can be introduced between the
case and ambient. This is where the heatsink in θCA is now split into θCS and θSA, where θS is the thermal
resistance of the interface compound used, and θSA is the thermal resistance of the heatsink. The equation
is now:
(3)
Rearranging this:
(4)
2 Understanding Thermal Dissipation and Design of a Heatsink SLVA462–May 2011
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
www.ti.com
In most cases, the TJ, PD, and θJC are given in the device manufacturer's data sheet; θCS and TA are used
as defined parameters. The ambient air temperature TA for cooling the devices depends on the operating
environment in which the component is expected to be used. Typically, it ranges from 35°C to 45°C, if the
external airflow through a fan is used and from 50°C to 60°C, if the component is enclosed. The interface
resistance θCS depends mainly on the interface material and its thickness and also on the surface finish,
flatness, applied mounting pressure, and contact area. Reliable data can be obtained directly from
material manufacturers.
With all the parameters defined, θSA becomes the required maximum thermal resistance of a heatsink for
the application. In other words, the thermal resistance value of a chosen heatsink for the application has to
be equal to or less than the previous θSA value for the junction temperature to be maintained at or below
that specified .
The following are the various important parameters in selecting a heatsink.
1. Thermal resistance θSA
2. Airflow
3. Volumetric resistance
4. Fin density
5. Fin spacing
6. Width
7. Length
The thermal resistance is one parameter that changes dynamically depending on the airflow available.
Airflow is typically measured in linear feet per minute (LFM) or CFM (cubic feet per minute). LFM is a
measure of velocity, whereas CFM is a measure of volume. Typically, fan manufacturers use CFM
because fans are rated according to the quantity of air it can move. Velocity (speed) is more meaningful
for heat removal at the board level, which is why the derating curves provided by most power converter
manufacturers use this. Typically, airflow is either classified as natural or forced convection. Natural
convection is a condition with no external induced flow and heat transfer depends on the air surrounding
the heatsink. The effect of radiation heat transfer is very important in natural convection, as it can be
responsible for approximately 25% of the total heat dissipation. Unless the component is facing a hotter
surface nearby, it is imperative to have the heatsink surfaces painted to enhance radiation. Forced
convection occurs when the flow of air is induced by mechanical means, usually a fan or blower.
Limited thermal budget and space make the choice of a particular type of heatsink very important. This is
where the volume of the heatsink becomes relevant. The volume of a heatsink for a given flow condition
can be obtained by using the following equation:
Volume(heatsink) = volumetric resistance (Cm3
°C/W)/thermal resistance θSA (°C/W)
An approximate range of volumetric resistance is given in the following table:
Available Airflow Volumetric Resistance
(LFM) (Cm3
°C/W)
NC 500 – 800
200 150 - 250
500 80 - 150
1000 50 - 80
The next important criterion for the performance of a heatsink is the width. It is linearly proportional to the
performance of the heatsink in the direction perpendicular to the airflow. Considering an example, an
increase in the width of a heatsink by a factor of two, three, or four increase the heat dissipation capability
by a factor of two, three, or four. Similarly, the square root of the fin length used is approximately
proportional to the performance of the heatsink in the direction parallel to the airflow. In case of an
increase in the length of the heatsink by a factor of two, three, or four only increases the heat dissipation
capability by a factor of 1.4, 1.7, or 2.
If the board has sufficient space, it is always beneficial to increase the width of a heatsink rather than the
length of the heatsink. This is only the beginning of an iterative process before the correct and the actual
heatsink design is achieved.
3SLVA462–May 2011 Understanding Thermal Dissipation and Design of a Heatsink
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products Applications
Audio www.ti.com/audio Communications and Telecom www.ti.com/communications
Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers
Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps
DLP® Products www.dlp.com Energy and Lighting www.ti.com/energy
DSP dsp.ti.com Industrial www.ti.com/industrial
Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical
Interface interface.ti.com Security www.ti.com/security
Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Power Mgmt power.ti.com Transportation and www.ti.com/automotive
Automotive
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com Wireless www.ti.com/wireless-apps
RF/IF and ZigBee® Solutions www.ti.com/lprf
TI E2E Community Home Page e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated

More Related Content

What's hot

Cooling and heating load calculations tide load4z
Cooling and heating load calculations tide load4zCooling and heating load calculations tide load4z
Cooling and heating load calculations tide load4zTin Arboladura
 
R&ac lecture 35
R&ac lecture 35R&ac lecture 35
R&ac lecture 35ZIAUL HAQUE
 
Heat gain valuees foe equipment
Heat gain valuees foe equipmentHeat gain valuees foe equipment
Heat gain valuees foe equipmentsaba arif
 
Load estimation in Air Conditioning
Load estimation in Air ConditioningLoad estimation in Air Conditioning
Load estimation in Air ConditioningParth Prajapati
 
H2 Plant presentation-2
H2 Plant presentation-2H2 Plant presentation-2
H2 Plant presentation-2Nageswar Rao
 
IRJET- Thermoelectric Air-Conditioner Tricycle
IRJET-  	  Thermoelectric Air-Conditioner TricycleIRJET-  	  Thermoelectric Air-Conditioner Tricycle
IRJET- Thermoelectric Air-Conditioner TricycleIRJET Journal
 
Mebs6006 0910 04-load
Mebs6006 0910 04-loadMebs6006 0910 04-load
Mebs6006 0910 04-loadnarazmi
 
Heat Load Calculation
Heat Load CalculationHeat Load Calculation
Heat Load CalculationJitendra Jha
 
HVAC Mini project review.pptx
HVAC Mini project review.pptxHVAC Mini project review.pptx
HVAC Mini project review.pptxCollege
 
Neutral sizing - Power cable
Neutral sizing - Power cableNeutral sizing - Power cable
Neutral sizing - Power cableLeonardo ENERGY
 
Total Liquid Cooling
Total Liquid CoolingTotal Liquid Cooling
Total Liquid CoolingIceotopePR
 
Heat transfer(HT) lab manual
Heat transfer(HT) lab manualHeat transfer(HT) lab manual
Heat transfer(HT) lab manualnmahi96
 
Microsoft word ms11 chapter 2 equipment selection-tcm135-60924
Microsoft word   ms11 chapter 2 equipment selection-tcm135-60924Microsoft word   ms11 chapter 2 equipment selection-tcm135-60924
Microsoft word ms11 chapter 2 equipment selection-tcm135-60924Yacine Gorary
 
Design planning & layout of high voltage laboratory
Design planning & layout of high voltage laboratoryDesign planning & layout of high voltage laboratory
Design planning & layout of high voltage laboratoryvishalgohel12195
 
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...Bishal Bhandari
 
Thermal transfer Characteristics of TCM
Thermal transfer Characteristics of TCMThermal transfer Characteristics of TCM
Thermal transfer Characteristics of TCMjlrapter
 

What's hot (20)

Cooling and heating load calculations tide load4z
Cooling and heating load calculations tide load4zCooling and heating load calculations tide load4z
Cooling and heating load calculations tide load4z
 
R&ac lecture 35
R&ac lecture 35R&ac lecture 35
R&ac lecture 35
 
Heat gain valuees foe equipment
Heat gain valuees foe equipmentHeat gain valuees foe equipment
Heat gain valuees foe equipment
 
Load estimation in Air Conditioning
Load estimation in Air ConditioningLoad estimation in Air Conditioning
Load estimation in Air Conditioning
 
H2 Plant presentation-2
H2 Plant presentation-2H2 Plant presentation-2
H2 Plant presentation-2
 
IRJET- Thermoelectric Air-Conditioner Tricycle
IRJET-  	  Thermoelectric Air-Conditioner TricycleIRJET-  	  Thermoelectric Air-Conditioner Tricycle
IRJET- Thermoelectric Air-Conditioner Tricycle
 
Lab%201
Lab%201Lab%201
Lab%201
 
28-shaw_presentation.ashx
28-shaw_presentation.ashx28-shaw_presentation.ashx
28-shaw_presentation.ashx
 
Mebs6006 0910 04-load
Mebs6006 0910 04-loadMebs6006 0910 04-load
Mebs6006 0910 04-load
 
Heat Load Calculation
Heat Load CalculationHeat Load Calculation
Heat Load Calculation
 
HVAC Mini project review.pptx
HVAC Mini project review.pptxHVAC Mini project review.pptx
HVAC Mini project review.pptx
 
Neutral sizing - Power cable
Neutral sizing - Power cableNeutral sizing - Power cable
Neutral sizing - Power cable
 
Total Liquid Cooling
Total Liquid CoolingTotal Liquid Cooling
Total Liquid Cooling
 
Heat transfer(HT) lab manual
Heat transfer(HT) lab manualHeat transfer(HT) lab manual
Heat transfer(HT) lab manual
 
Ht 7
Ht 7Ht 7
Ht 7
 
Microsoft word ms11 chapter 2 equipment selection-tcm135-60924
Microsoft word   ms11 chapter 2 equipment selection-tcm135-60924Microsoft word   ms11 chapter 2 equipment selection-tcm135-60924
Microsoft word ms11 chapter 2 equipment selection-tcm135-60924
 
Design planning & layout of high voltage laboratory
Design planning & layout of high voltage laboratoryDesign planning & layout of high voltage laboratory
Design planning & layout of high voltage laboratory
 
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...
 
Thermal transfer Characteristics of TCM
Thermal transfer Characteristics of TCMThermal transfer Characteristics of TCM
Thermal transfer Characteristics of TCM
 
Enercon AEROGENERADOR
Enercon AEROGENERADOREnercon AEROGENERADOR
Enercon AEROGENERADOR
 

Similar to Heat sink

10 Steps in Telecom Thermal Management
10 Steps in Telecom Thermal Management  10 Steps in Telecom Thermal Management
10 Steps in Telecom Thermal Management Kamal Karimanal
 
THERMAL ANALYSIS OF A HEAT SINK FOR ELECTRONICS COOLING
THERMAL ANALYSIS OF A HEAT SINK FOR ELECTRONICS COOLINGTHERMAL ANALYSIS OF A HEAT SINK FOR ELECTRONICS COOLING
THERMAL ANALYSIS OF A HEAT SINK FOR ELECTRONICS COOLINGIAEME Publication
 
Thermal Analysis of a Linear Voltage Regulator
Thermal Analysis of a Linear Voltage RegulatorThermal Analysis of a Linear Voltage Regulator
Thermal Analysis of a Linear Voltage RegulatorIonela
 
Numerical Investigation of Forced Convection cooling of Electrical enclosure ...
Numerical Investigation of Forced Convection cooling of Electrical enclosure ...Numerical Investigation of Forced Convection cooling of Electrical enclosure ...
Numerical Investigation of Forced Convection cooling of Electrical enclosure ...IJERA Editor
 
Selecting air conditioners for enclosure
Selecting air conditioners for enclosureSelecting air conditioners for enclosure
Selecting air conditioners for enclosureerdinc klima
 
cable sizing.ppt
cable sizing.pptcable sizing.ppt
cable sizing.pptChadWood16
 
Thermal Management of Edge Data Centers
Thermal Management of Edge Data Centers Thermal Management of Edge Data Centers
Thermal Management of Edge Data Centers Raptor Power Systems
 
Input devices power
Input devices powerInput devices power
Input devices powerJeff Valerio
 
unit3Heating,cooling and mounting.pdf
unit3Heating,cooling and mounting.pdfunit3Heating,cooling and mounting.pdf
unit3Heating,cooling and mounting.pdfnodov66591
 
2_Fuse_Characteristics.pdf
2_Fuse_Characteristics.pdf2_Fuse_Characteristics.pdf
2_Fuse_Characteristics.pdfssuser244f27
 
Axiom: Ensure Trouble-Free Supercapacitor Operation with Proper Component Sel...
Axiom: Ensure Trouble-Free Supercapacitor Operation with Proper Component Sel...Axiom: Ensure Trouble-Free Supercapacitor Operation with Proper Component Sel...
Axiom: Ensure Trouble-Free Supercapacitor Operation with Proper Component Sel...Avnet Electronics Marketing
 
A Study on Stochastic Thermal Characterization of Electronic Packages
A Study on Stochastic Thermal Characterization of Electronic PackagesA Study on Stochastic Thermal Characterization of Electronic Packages
A Study on Stochastic Thermal Characterization of Electronic PackagesIJERA Editor
 
A 2D MODELLING OF THERMAL HEAT SINK FOR IMPATT AT HIGH POWER MMW FREQUENCY
A 2D MODELLING OF THERMAL HEAT SINK FOR IMPATT AT HIGH POWER MMW FREQUENCYA 2D MODELLING OF THERMAL HEAT SINK FOR IMPATT AT HIGH POWER MMW FREQUENCY
A 2D MODELLING OF THERMAL HEAT SINK FOR IMPATT AT HIGH POWER MMW FREQUENCYcscpconf
 
Thermal analysis of cpu with variable baseplate heat sink using cfd
Thermal analysis of cpu with variable baseplate heat sink using cfdThermal analysis of cpu with variable baseplate heat sink using cfd
Thermal analysis of cpu with variable baseplate heat sink using cfdeSAT Publishing House
 
Power electronic capacitors
Power electronic capacitorsPower electronic capacitors
Power electronic capacitorsMinka Grdesic
 
IRJET- Critical Analysis of Thermoelectric Cycle (Tri-Cycle)
IRJET- Critical Analysis of Thermoelectric Cycle (Tri-Cycle)IRJET- Critical Analysis of Thermoelectric Cycle (Tri-Cycle)
IRJET- Critical Analysis of Thermoelectric Cycle (Tri-Cycle)IRJET Journal
 
Pe lec-thermal design-1
Pe lec-thermal design-1Pe lec-thermal design-1
Pe lec-thermal design-1Sharif Ullah
 
KEMET Webinar -C44U_C44P-R Power Can Film Capacitors
KEMET Webinar -C44U_C44P-R Power Can Film CapacitorsKEMET Webinar -C44U_C44P-R Power Can Film Capacitors
KEMET Webinar -C44U_C44P-R Power Can Film CapacitorsIvana Ivanovska
 

Similar to Heat sink (20)

10 Steps in Telecom Thermal Management
10 Steps in Telecom Thermal Management  10 Steps in Telecom Thermal Management
10 Steps in Telecom Thermal Management
 
THERMAL ANALYSIS OF A HEAT SINK FOR ELECTRONICS COOLING
THERMAL ANALYSIS OF A HEAT SINK FOR ELECTRONICS COOLINGTHERMAL ANALYSIS OF A HEAT SINK FOR ELECTRONICS COOLING
THERMAL ANALYSIS OF A HEAT SINK FOR ELECTRONICS COOLING
 
Thermal Analysis of a Linear Voltage Regulator
Thermal Analysis of a Linear Voltage RegulatorThermal Analysis of a Linear Voltage Regulator
Thermal Analysis of a Linear Voltage Regulator
 
Numerical Investigation of Forced Convection cooling of Electrical enclosure ...
Numerical Investigation of Forced Convection cooling of Electrical enclosure ...Numerical Investigation of Forced Convection cooling of Electrical enclosure ...
Numerical Investigation of Forced Convection cooling of Electrical enclosure ...
 
Selecting air conditioners for enclosure
Selecting air conditioners for enclosureSelecting air conditioners for enclosure
Selecting air conditioners for enclosure
 
cable sizing.ppt
cable sizing.pptcable sizing.ppt
cable sizing.ppt
 
Thermal Management of Edge Data Centers
Thermal Management of Edge Data Centers Thermal Management of Edge Data Centers
Thermal Management of Edge Data Centers
 
Input devices power
Input devices powerInput devices power
Input devices power
 
HVAC CAPSULEEMERSON EDUARDO RODRIGUES
HVAC CAPSULEEMERSON EDUARDO RODRIGUESHVAC CAPSULEEMERSON EDUARDO RODRIGUES
HVAC CAPSULEEMERSON EDUARDO RODRIGUES
 
HVAC CAPSULE EMERSON EDUARDO RODRIGUES
HVAC CAPSULE EMERSON EDUARDO RODRIGUESHVAC CAPSULE EMERSON EDUARDO RODRIGUES
HVAC CAPSULE EMERSON EDUARDO RODRIGUES
 
unit3Heating,cooling and mounting.pdf
unit3Heating,cooling and mounting.pdfunit3Heating,cooling and mounting.pdf
unit3Heating,cooling and mounting.pdf
 
2_Fuse_Characteristics.pdf
2_Fuse_Characteristics.pdf2_Fuse_Characteristics.pdf
2_Fuse_Characteristics.pdf
 
Axiom: Ensure Trouble-Free Supercapacitor Operation with Proper Component Sel...
Axiom: Ensure Trouble-Free Supercapacitor Operation with Proper Component Sel...Axiom: Ensure Trouble-Free Supercapacitor Operation with Proper Component Sel...
Axiom: Ensure Trouble-Free Supercapacitor Operation with Proper Component Sel...
 
A Study on Stochastic Thermal Characterization of Electronic Packages
A Study on Stochastic Thermal Characterization of Electronic PackagesA Study on Stochastic Thermal Characterization of Electronic Packages
A Study on Stochastic Thermal Characterization of Electronic Packages
 
A 2D MODELLING OF THERMAL HEAT SINK FOR IMPATT AT HIGH POWER MMW FREQUENCY
A 2D MODELLING OF THERMAL HEAT SINK FOR IMPATT AT HIGH POWER MMW FREQUENCYA 2D MODELLING OF THERMAL HEAT SINK FOR IMPATT AT HIGH POWER MMW FREQUENCY
A 2D MODELLING OF THERMAL HEAT SINK FOR IMPATT AT HIGH POWER MMW FREQUENCY
 
Thermal analysis of cpu with variable baseplate heat sink using cfd
Thermal analysis of cpu with variable baseplate heat sink using cfdThermal analysis of cpu with variable baseplate heat sink using cfd
Thermal analysis of cpu with variable baseplate heat sink using cfd
 
Power electronic capacitors
Power electronic capacitorsPower electronic capacitors
Power electronic capacitors
 
IRJET- Critical Analysis of Thermoelectric Cycle (Tri-Cycle)
IRJET- Critical Analysis of Thermoelectric Cycle (Tri-Cycle)IRJET- Critical Analysis of Thermoelectric Cycle (Tri-Cycle)
IRJET- Critical Analysis of Thermoelectric Cycle (Tri-Cycle)
 
Pe lec-thermal design-1
Pe lec-thermal design-1Pe lec-thermal design-1
Pe lec-thermal design-1
 
KEMET Webinar -C44U_C44P-R Power Can Film Capacitors
KEMET Webinar -C44U_C44P-R Power Can Film CapacitorsKEMET Webinar -C44U_C44P-R Power Can Film Capacitors
KEMET Webinar -C44U_C44P-R Power Can Film Capacitors
 

Recently uploaded

Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...ranjana rawat
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).pptssuser5c9d4b1
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 

Recently uploaded (20)

Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 

Heat sink

  • 1. -J A JA D T T θ = P -JMAX A DMAX JA T T P = θ Application Report SLVA462–May 2011 Understanding Thermal Dissipation and Design of a Heatsink Nikhil Seshasayee ...................................................................................... PMP DCS dc/dc Controllers ABSTRACT Power dissipation performance must be well understood prior to integrating devices on a printed-circuit board (PCB) to ensure that any given device is operated within its defined temperature limits. When a device is running, it consumes electrical energy that is transformed into heat. Most of the heat is typically generated by switching devices like MOSFETs, ICs, etc. This application report discusses the thermal dissipation terminology and how to design a proper heatsink for a given dissipation limit. Thermal Dissipation The maximum allowable junction temperature (TJMAX) is one of the key factors that limit the power dissipation capability of a device. TJMAX is defined by the manufacturer and usually depends on the reliability of the die used in the manufacturing process. The typical equation used for calculation of the dissipation is shown in Equation 2: (1) Where: θJA = thermal resistance TJ = junction temperature TA = ambient temperature PD = power dissipation To discover the maximum power that the device can dissipate, rearrange Equation 2 to: (2) With the help of θJA and TJMAX, which are mentioned in the TPS54325 data sheet (SLVS932), PDMAX is calculated. For example, in the data sheet, θJA is mentioned at 44.5°C/W and TJMAX is given as 125°C. Using this at different ambient conditions of 25°C and 85°C, one can arrive at the values mentioned in the data sheet of 2.25 W and 0.9 W, respectively. A parameter called derating factor can be derived from this. The derating factor is linear, so if the dissipation is 2250 mW for a 100°C rise (from 25°C to 125°C), for each one degree increase in ambient temperature, the power dissipation rating has to be decreased 2250/100 = 22.50 mW/°C. This parameter is sometimes used for calculation, when the power dissipation values are unspecified. In a specific synchronous buck converter application where the input is 5 V and output is 2.5 V at 1 A, 2.5 W is delivered to the load. Note that this is not the power dissipated in the device. When no specific efficiency curves are in a data sheet for the application, an assumption of the efficiency is to be considered (90%) to calculate the input power. So, the input power in this case is approximately 2.5/0.9 = 2.75 W, and the power dissipation in the converter is approximately 2.75 – 2.5 = 0.25 W. Some of this power is dissipated in the inductor, which is external to the chipset. Because the DCR can be known from the inductor data sheet, the inductor power is: Pinductor = Iout2 × DCR = 12 × 100 × 10-3 = 100 mW. The device power dissipation is now 250 mW - 100 mW = 150 mW, and the junction temperature rise above ambient is calculated using the formula: 1SLVA462–May 2011 Understanding Thermal Dissipation and Design of a Heatsink Submit Documentation Feedback Copyright © 2011, Texas Instruments Incorporated
  • 2. - JA JC CS SA J A JC CS SA D θ = θ + θ + θ T T = θ + θ + θ P - - -J A SA JC CS D T T θ = θ θ P www.ti.com (θJA × PD) + TA = TJ TJ = 75 × 0.15 + TA = 11.25°C above ambient (75°C/W is the thermal resistance taken as a example) Consider another example of calculating the dissipation of a logic device SN74ACT240. Based on the data sheet specifications of the device and actual operating conditions, power dissipated by the logic can be estimated as per the preceding equations. The device power dissipation consists of two basic components – the unloaded power dissipation inherent to the device and the load power dissipation, which is a function of the device loading. PD(total) = PD(unloaded) + PD(loaded) Power dissipation in an unloaded logic device can be calculated using the following equations: PD(unloaded) = VCC × IC IC = ICC + Iinput + Idynamic Where: VCC = supply voltage ICC = quiescent current Iinput = total current when inputs are high Idynamic = power supply current per unit frequency Iinput = II × NI × DI and Idynamic = Cpd × Vcc Where: II = supply current for a high input NI = number of inputs on high level DI = duty cycle of inputs at high level Cpd = power dissipation capacitance The loading of a logic device can significantly effect the power dissipation. Most of the logic loads appear to be capacitive, leading to more of dynamic power dissipation. Typical load capacitance is approximately 10 pF to 20 pF. Power dissipation in a loaded logic device can be calculated using the following equations: PD(loaded) = VOH × NO × f × CL Where: VOH = logic high output voltage NO = number of outputs loaded with CL f = output switching frequency CL = load capacitance per output Heatsink Design θJA is actually made up of at least two separate thermal resistances in series. One is the thermal resistance inside the device package, between the junction and its outside case, called θJC. The other is the resistance between the case and the ambient, θCA . Because θJC is under the control of the manufacturer, nothing can be done with it. It is typically low. Another stage can be introduced between the case and ambient. This is where the heatsink in θCA is now split into θCS and θSA, where θS is the thermal resistance of the interface compound used, and θSA is the thermal resistance of the heatsink. The equation is now: (3) Rearranging this: (4) 2 Understanding Thermal Dissipation and Design of a Heatsink SLVA462–May 2011 Submit Documentation Feedback Copyright © 2011, Texas Instruments Incorporated
  • 3. www.ti.com In most cases, the TJ, PD, and θJC are given in the device manufacturer's data sheet; θCS and TA are used as defined parameters. The ambient air temperature TA for cooling the devices depends on the operating environment in which the component is expected to be used. Typically, it ranges from 35°C to 45°C, if the external airflow through a fan is used and from 50°C to 60°C, if the component is enclosed. The interface resistance θCS depends mainly on the interface material and its thickness and also on the surface finish, flatness, applied mounting pressure, and contact area. Reliable data can be obtained directly from material manufacturers. With all the parameters defined, θSA becomes the required maximum thermal resistance of a heatsink for the application. In other words, the thermal resistance value of a chosen heatsink for the application has to be equal to or less than the previous θSA value for the junction temperature to be maintained at or below that specified . The following are the various important parameters in selecting a heatsink. 1. Thermal resistance θSA 2. Airflow 3. Volumetric resistance 4. Fin density 5. Fin spacing 6. Width 7. Length The thermal resistance is one parameter that changes dynamically depending on the airflow available. Airflow is typically measured in linear feet per minute (LFM) or CFM (cubic feet per minute). LFM is a measure of velocity, whereas CFM is a measure of volume. Typically, fan manufacturers use CFM because fans are rated according to the quantity of air it can move. Velocity (speed) is more meaningful for heat removal at the board level, which is why the derating curves provided by most power converter manufacturers use this. Typically, airflow is either classified as natural or forced convection. Natural convection is a condition with no external induced flow and heat transfer depends on the air surrounding the heatsink. The effect of radiation heat transfer is very important in natural convection, as it can be responsible for approximately 25% of the total heat dissipation. Unless the component is facing a hotter surface nearby, it is imperative to have the heatsink surfaces painted to enhance radiation. Forced convection occurs when the flow of air is induced by mechanical means, usually a fan or blower. Limited thermal budget and space make the choice of a particular type of heatsink very important. This is where the volume of the heatsink becomes relevant. The volume of a heatsink for a given flow condition can be obtained by using the following equation: Volume(heatsink) = volumetric resistance (Cm3 °C/W)/thermal resistance θSA (°C/W) An approximate range of volumetric resistance is given in the following table: Available Airflow Volumetric Resistance (LFM) (Cm3 °C/W) NC 500 – 800 200 150 - 250 500 80 - 150 1000 50 - 80 The next important criterion for the performance of a heatsink is the width. It is linearly proportional to the performance of the heatsink in the direction perpendicular to the airflow. Considering an example, an increase in the width of a heatsink by a factor of two, three, or four increase the heat dissipation capability by a factor of two, three, or four. Similarly, the square root of the fin length used is approximately proportional to the performance of the heatsink in the direction parallel to the airflow. In case of an increase in the length of the heatsink by a factor of two, three, or four only increases the heat dissipation capability by a factor of 1.4, 1.7, or 2. If the board has sufficient space, it is always beneficial to increase the width of a heatsink rather than the length of the heatsink. This is only the beginning of an iterative process before the correct and the actual heatsink design is achieved. 3SLVA462–May 2011 Understanding Thermal Dissipation and Design of a Heatsink Submit Documentation Feedback Copyright © 2011, Texas Instruments Incorporated
  • 4. IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP® Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and www.ti.com/automotive Automotive Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com Wireless www.ti.com/wireless-apps RF/IF and ZigBee® Solutions www.ti.com/lprf TI E2E Community Home Page e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2011, Texas Instruments Incorporated