3. 45 Left and Right Movement Durability Test Rig.
The Scope of Test Rig development involves the following:
Automatic adjustment of Base Frame Height Depending on the UUT through Static
Load Hydraulic Actuator (Travel up to 300 mm).
Application of 300 -350 Newton Hydraulic Load at an angle of 450 to the UUT at
20 CPM (This can be adjusted between 0-20 CPM)
Load Application Cycle to be applied is
Step i: Load on Left
Step ii: Load on Right
Dynamic Hydraulic Actuator Selection Should be for 150 mm Travel and it should
be capable of applying up to 5000 Newton Load
Measurement of Load applied (load Cell of 5 kN capacity)
Display, Storage and Report Generation of the Data
4.
5. SS 304 Tank-150 liters with necessary fittings & mountings, Drain
Valve (Audco).
Level Switch, level Gauge, temperature Switch, Filler Breather.
Parker Make Pump/ Motor System with Couplings/ Mountings &
Frame
Pressure Regulator, Tescom/ Parker Make
Flow Control Valve
6.
7. Items Description
24 Volts DC Power supply 5 amp (DR-120-24)
LED 24 volts DC(Red) 24 V DC
LED 24 volts DC(Green) 24 V DC
Contactor 9 amp, 24 volt(coil)
Thermal OLR 2-5 Amp
Terminal for Power (thick
wire)
UK-10
MCB TP, 6 Amp
MCB DP, 6 Amp
Green Terminal (GND) UK-2.5
Terminal (Neutral) UK-2.5
Red Terminal UK-2.5
Black Terminal UK-2.5
relay 24 volts DC, 6 amp.
8. Application of 300 -350 Newton Hydraulic Load at an
angle of 450 to the UUT at 20 CPM (This can be
adjusted between 0-20 CPM). Dynamic Hydraulic
Actuator Selection Should be for 150 mm Travel and it
should be capable of applying up to 5000 Newton
Load. Measurement of Load applied (load Cell of 5 kN
capacity).