2. Disusun Oleh :
•M. Achdi
•Mahfud Anas
•Farid Rinanto
•M. Imam Machdi
•Rian Septian
•Rio Darmawan
•Ridwan Irwansyah
3. Device & Inisial
T = TEMPERATURE
M = MOTOR MIX
H = HEATING
P1 = MOTOR POMPA KE TABUNG WATER
P2 = MOTOR POMPA KE TABUNG SUGAR
P3 = MOTOR POMPA KE TABUNG COCO MIX
P4 = MOTOR POMPA KE TABUNG PEMANAS
P5 = MOTOR POMPA KE PENAMPUNGAN SEMENTARA
PB STOP
PB START
SELECTOR SWITCH
EMERGENCY
6. Algoritma
SAAT START, JIKA TABUNG PENAMPUNGAN WATER, SUGAR, COCO MIX KOSONG MAKA
DILAKUKAN PENGISIAN SECARA MANUAL UNTUK KETIGANYA HINGGA STATUS
MENGINDIKASIKAN “READY” .
SELANJUTNYA, PILIH SELECTOR SWITCH KE POSISI “AUTO” UNTUK MELAKUKAN
PROSES PENYUPLAYAN WATER, SUGAR DAN COCO MIX YANG DI DRIVE OLEH
MASING – MASING MOTOR POMPA P1, P2 , DAN P3.
PENYUPLAYAIN SELESAI HINGGA TABUNG MIXING MENCAPAI LEVEL YANG TELAH
DITENTUKAN. PEMBACAAN LEVEL MENGGUNAKAN SENSOR ULTRASONIK YANG
MENGIRIMKAN SINYAL ANALOG KE PLC.
SETELAH ITU MOTOR MIXING (M) ON UNTUK MELAKUKAN PROSES MIXING.
PROSES MIXING DILAKUKAN HINGGA WAKTU YANG SUDAH DITENTUKAN.
SELESAI PROSES MIXING BAHAN YANG SUDAH TERCAMPUR DIPOMPA OLEH P4
MENUJU TABUNG PEMANAS. PROSES PEMANASAN DILAKUKAN HINGGA MENCAPAI
SUHU YANG DITENTUKAN.
KEMUDIAN PEROSES DISTRIBUSI KE KEMASAN DILAKUKAN UNTUK SEBELUMNYA
DITAMPUNG DI TANKI PENAMPUNGAN SEMENTARA (PEMOMPAAN DILAKUKAN OLEH
P5).
PEROSES SELESAI. PROSES KEMBALI DARI AWAL KETIKA TABUNG WATER, SUGAR
DAN COCO MIX KEMBALI KOSONG.
7. START
Init. P1, P2, P2,
P3
Int. P4, P5
Int. T, M, H
Pb. Start, Pb. Stop
Seectotor switch,
emergency stop
Start
Tank
water
=0
IsiTankiWater
Level
High
Level
High
Tanki
coco
mix =
0
Tank
sugar
= 0
IsiTanki sugar
IsiTanki
Coco Mix
Level
High
NO
NO
NO
yes
yes
yes
P1, P2, P3
= ON
Level
tanki
mixing
= High
A
NO
yes
PROGRAM AUTO
No
No
No
yes
8. A
Timer
= aktif
M =ON P5 = ON
Heater ( H)
= ON
Heater ( H)
= Off
P5 = ON
END
Water
Level
2 =
aktif
Suhu
= set
poin
Timer ++
no
no no
yes yes yesyes