The document discusses research on modifying titanium surfaces for dental implants. The goals are to immobilize collagen onto titanium through a coupling agent to improve osseointegration. The methodology includes blasting titanium with hydroxyapatite or aluminum oxide, acid etching, grafting with 3-aminopropyltriethoxysilane, and collagen coating. Preliminary results found hydroxyapatite blasting produced lower surface roughness than aluminum oxide blasting and acid etching reduced roughness. Future plans include heat treatment, XPS analysis, and cell tests to evaluate collagen coatings.