1. The bending moment at the center of a simply supported beam carrying a uniformly distributed load is equal to wl^2/4.
2. The shear force at a point on a beam is the algebraic sum of all the forces on either side of that point.
3. A point of contraflexure occurs in overhanging beams where the bending moment changes sign.
Analysis of indeterminate beam by slopeand deflection methodnawalesantosh35
Slope-deflection method ,Slope-deflection equations, equilibrium equation of
method, application to beams with and without joint translation and rotation, Sinking or yielding of support,
Analysis of indeterminate beam by slopeand deflection methodnawalesantosh35
Slope-deflection method ,Slope-deflection equations, equilibrium equation of
method, application to beams with and without joint translation and rotation, Sinking or yielding of support,
Aiims previous year sample paper set 2Prabha Gupta
Find here previous year AIIMS question papers and solved sample question bank with answer keys at Aglasem. Visit @ https://admission.aglasem.com/aiims-mbbs-2019/
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
TECHNICAL TRAINING MANUAL GENERAL FAMILIARIZATION COURSEDuvanRamosGarzon1
AIRCRAFT GENERAL
The Single Aisle is the most advanced family aircraft in service today, with fly-by-wire flight controls.
The A318, A319, A320 and A321 are twin-engine subsonic medium range aircraft.
The family offers a choice of engines
Courier management system project report.pdfKamal Acharya
It is now-a-days very important for the people to send or receive articles like imported furniture, electronic items, gifts, business goods and the like. People depend vastly on different transport systems which mostly use the manual way of receiving and delivering the articles. There is no way to track the articles till they are received and there is no way to let the customer know what happened in transit, once he booked some articles. In such a situation, we need a system which completely computerizes the cargo activities including time to time tracking of the articles sent. This need is fulfilled by Courier Management System software which is online software for the cargo management people that enables them to receive the goods from a source and send them to a required destination and track their status from time to time.
Saudi Arabia stands as a titan in the global energy landscape, renowned for its abundant oil and gas resources. It's the largest exporter of petroleum and holds some of the world's most significant reserves. Let's delve into the top 10 oil and gas projects shaping Saudi Arabia's energy future in 2024.
Top 10 Oil and Gas Projects in Saudi Arabia 2024.pdf
Strength of Materials online test 1
1. Kongu Engineering Colege, Perundurai-63060
Department of Mechanical Engineering
Strength of Materials
Online Test – 2 16.04.2020
Part A
Answer all the questions (20*1 = 20 marks)
1. The bending moment in the center of a simply supported beam carrying a uniformly
distributed load of w per unit length is
a) zero
b) wl2
/2
c) wl2
/4
d) wl2
/8
2. The shear force at a point on a beam is the __________ of all the forces on either side of
the point.
a) Algebraicdifference
b) Algebraicsum
c) Multiplication
d) Division
3. The point of contra flexure occurs in
a) cantilever beams
b) simply supported beams
c) overhanging beams
d) fixed beams
4. A beam of uniform strength has
a) same cross-section throughout the beam
b) same bending stress at every section
2. c) same bending moment at every section
d) same shear stress at every section
5. The shear force of a simply supported beam carrying a central point load changes sign at
a) RHS
b) LHS
c) At Midpoint
d) Other than midpoint
6. In a simple bending theory, one of the assumption is that the material of the beam is
isotropic. This assumption means that the
a) normal stress remains constant in all directions
b) normal stress varies linearly in the material
c) elastic constants are same in all the directions
d) elastic constants varies linearly in the material
7. The bending moment of a cantilever beam of length l and carrying a gradually varying
load from zero at free end and w per unit length at the fixed end is __________ at the
fixed end.
a) wl/2
b) wl
c) wl2/2
d) wl2/6
8. An overhanging beam must overhang on
a) On one side and support
b) On two side and support
c) Both side
d) On two side and fixed
9. In a beam where shear force changes sign, the bending moment will be
3. a) Zero
b) Minimum
c) Maximum
d) Infinity
10. The maximum shear stress of a beam of triangular section occurs at,
a) above the neutral axis
b) below the neutral axis
c) At neutral axis
d) Other than neutral axis
11. For the beam shown in the below figure, the shear force at A is equal to
a) wl/6
b) wl/3
c) wl
d) 2 wl/3
12. When a rectangular beam is loaded transversely, the zero stress is developed on
a) above the neutral axis
b) below the neutral axis
c) At neutral axis
d) Other than neutral axis
13. The shear force diagram for a simply supported beam carrying a uniformly distributed
load of w per unit length, consists of
a) one right angled triangle
4. b) two right angled triangles
c) one equilateral triangle
d) two equilateral triangles
14. When a cantilever beam is loaded at its free end, the maximum compressive stress shall
develop at
a) bottom fibre
b) top fibre
c) neutral axis
d) centre of gravity
15. In a cantilever beam of length l subjected to a uniformly distributed load of w per unit
length, the maximum bending moment lies at the.
a) Fixed end
b) Free end
c) Midpoint
d) Other than midpoint
16. When the shear force diagram is a parabolic curve between two points, it indicates that
there is a
a) point load at the two points
b) no loading between the two points
c) uniformly distributed load between the two points
d) uniformly varying load between the two points
17. Flitched beam also called
a) Homogeneous beam
b) Heterogeneous beam
c) Horizontal beam
d) Vertical beam
5. 18. Virtual hinge also called as
a) Maximum bending moment
b) Point of contraflexure
c) Maximum shear force
d) Zero bending moment
19. In a cantilever, carrying a load whose intensity varies uniformly from zero at free end to
maximum at fixed end, the BM changes following a
a) Linear law
b) Parabolic law
c) Cubic law
d) Curved law
20. Which of the following are the statically indeterminate beams?
a) Fixed beam
b) Continues beam
c) Cantilever beam
d) Both a and b
Part B
Answer any two questions (02*15 = 30 marks)
21. Find maximum bending moment for the beam shown below
6. E
C D
1.5 KN/m
A B
6 m
1 KN 2 KN 3 KN
4.5 m
1.5 m
3 m
a) 6.5 KN m
b) 84.75 KN m
c) 1.275 KN m
d) 12.75 KN m
22. Find Maximum Bending moment for the beam shown below. (8 Marks)
8 m
1.5 KN/m
B
6 m
A
a) 5.33 KN m
b) 15.23 KN m
c) 105.32 KN m
d) 0.2145 KN m
22 b. Find point of contra flexure for the above problem. (7 Marks)
a) 5.33 m from left support
b) 5.33 m from right support
c) 10.33 m from left support
7. d) 5.33 m from right support
23. Find suitable dimensions (breadth, depth) for the rectangular cross section of the beam
shown in figure. The bending stress of the beam is not to exceed 8 N/mm2
b
d
=
2b
C
12 KN/m
A B
8 m
10 KN
3 m
a) 323.5 mm, 647 mm
b) 275.5 mm, 551 mm
c) 1245.5 mm, 2491 mm
d) 875.5 mm, 1313.25 mm