Servomax is a well know and established company in delivering Power Distribution Unit, Electric Equipments manufacturers, suppliers of Power Distribution Unit india, indian Electric Equipments.
The Climate Control Unit is designed to control the environment of small to medium outdoor telecom cabinets. It can control fans, heat exchangers, heaters, lighting and detect high/low temperatures, humidity, water, intrusion and smoke. It has a wide operating temperature range of -40°C to +70°C and input power range of 18-59Vdc. It provides temperature control, alarm functions, and easy operation via LED display and indicators.
This document provides information about the DP 2700 Power Module, including:
1. It has a -48V/56A DC output with a maximum power of 2700W and wide input voltage range of 90V-300V.
2. It uses power factor correction and has a compact size of 42mm/1U wide, 125.5mm/3U high, and 268mm deep, weighing 2.0 kg.
3. It has features like high efficiency over 92% at 48V, fan cooling with an easy replaceable fan, operating temperature range of -5°C to +75°C, and protections for overvoltage, overtemperature, short circuit, and more.
The document discusses several applications for SED2 variable frequency drives including temperature control, pressure control, belt monitoring, and duct pressure control. It provides examples of input/output configurations and solutions using the built-in functions of the SED2 drive like PID control, pump cascading logic, and static pressure control. It also reviews mounting and installation considerations for selecting the proper enclosure type and installing line and load reactors.
The document is a data sheet for the DS-247-128 absolute position rotary electric encoder. It provides specifications for the encoder including its low profile design, hollow shaft, high precision and tolerance to environmental factors. It outputs either analog sine/cosine waves or digital quadrature signals and has options for various interfaces like SSi or A/B/Index. It is suited for applications requiring high accuracy like aerospace and medical equipment.
The STM is an integrated step motor and drive device that combines a step motor and drive electronics into a single unit. This offers space, wiring, and cost savings over separate motor and drive solutions. The STM provides various control modes including pulse and direction, velocity control, and execution of programmed motion sequences. Models are available with different communications interfaces like RS-232, RS-485, and CANopen.
The Model PK200 Current-to-Pneumatic Converter:
- Converts a 4-20mA or 10-50mA input current signal to a proportional pneumatic output signal.
- Has adjustable zero and span settings, high accuracy and reliability, and is minimally affected by environmental conditions.
- Is used to actuate pneumatic devices like valves and cylinders, as well as for signal conversion in hybrid instrumentation systems.
Siemens Terminal Box Controller (APOGEE Automation System )CONTROLS & SYSTEMS
The document describes the Siemens Terminal Box Controller, which provides direct digital control for variable air volume HVAC systems. The controller can operate independently or as part of the APOGEE Automation System to control various HVAC applications. It interfaces with sensors, actuators, and the Portable Operator's Terminal for monitoring and configuration. Key features include PID control, unique control algorithms, HVAC diagnostics, and energy management capabilities.
Study Of 30W Digital Audio Amplifier with Integrated ADC: CS4525Premier Farnell
The document summarizes a study of the CS4525 30W digital audio amplifier with an integrated analog-to-digital converter (ADC) from Cirrus Logic. The amplifier has fully integrated power MOSFETs, a built-in protection system, and a 24-bit 48 kHz ADC. It can be configured for various output configurations including half-bridge, full-bridge, and parallel modes to power multiple speakers and subwoofers. The document provides details on features, specifications, typical application diagrams, and configuration options.
The Climate Control Unit is designed to control the environment of small to medium outdoor telecom cabinets. It can control fans, heat exchangers, heaters, lighting and detect high/low temperatures, humidity, water, intrusion and smoke. It has a wide operating temperature range of -40°C to +70°C and input power range of 18-59Vdc. It provides temperature control, alarm functions, and easy operation via LED display and indicators.
This document provides information about the DP 2700 Power Module, including:
1. It has a -48V/56A DC output with a maximum power of 2700W and wide input voltage range of 90V-300V.
2. It uses power factor correction and has a compact size of 42mm/1U wide, 125.5mm/3U high, and 268mm deep, weighing 2.0 kg.
3. It has features like high efficiency over 92% at 48V, fan cooling with an easy replaceable fan, operating temperature range of -5°C to +75°C, and protections for overvoltage, overtemperature, short circuit, and more.
The document discusses several applications for SED2 variable frequency drives including temperature control, pressure control, belt monitoring, and duct pressure control. It provides examples of input/output configurations and solutions using the built-in functions of the SED2 drive like PID control, pump cascading logic, and static pressure control. It also reviews mounting and installation considerations for selecting the proper enclosure type and installing line and load reactors.
The document is a data sheet for the DS-247-128 absolute position rotary electric encoder. It provides specifications for the encoder including its low profile design, hollow shaft, high precision and tolerance to environmental factors. It outputs either analog sine/cosine waves or digital quadrature signals and has options for various interfaces like SSi or A/B/Index. It is suited for applications requiring high accuracy like aerospace and medical equipment.
The STM is an integrated step motor and drive device that combines a step motor and drive electronics into a single unit. This offers space, wiring, and cost savings over separate motor and drive solutions. The STM provides various control modes including pulse and direction, velocity control, and execution of programmed motion sequences. Models are available with different communications interfaces like RS-232, RS-485, and CANopen.
The Model PK200 Current-to-Pneumatic Converter:
- Converts a 4-20mA or 10-50mA input current signal to a proportional pneumatic output signal.
- Has adjustable zero and span settings, high accuracy and reliability, and is minimally affected by environmental conditions.
- Is used to actuate pneumatic devices like valves and cylinders, as well as for signal conversion in hybrid instrumentation systems.
Siemens Terminal Box Controller (APOGEE Automation System )CONTROLS & SYSTEMS
The document describes the Siemens Terminal Box Controller, which provides direct digital control for variable air volume HVAC systems. The controller can operate independently or as part of the APOGEE Automation System to control various HVAC applications. It interfaces with sensors, actuators, and the Portable Operator's Terminal for monitoring and configuration. Key features include PID control, unique control algorithms, HVAC diagnostics, and energy management capabilities.
Study Of 30W Digital Audio Amplifier with Integrated ADC: CS4525Premier Farnell
The document summarizes a study of the CS4525 30W digital audio amplifier with an integrated analog-to-digital converter (ADC) from Cirrus Logic. The amplifier has fully integrated power MOSFETs, a built-in protection system, and a 24-bit 48 kHz ADC. It can be configured for various output configurations including half-bridge, full-bridge, and parallel modes to power multiple speakers and subwoofers. The document provides details on features, specifications, typical application diagrams, and configuration options.
Catalog biến tần Frenic eHVAC - beeteco.com
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Địa chỉ : Số 7/31 KDC Thương Mại Sóng Thần, KP. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Tỉnh Bình Dương
FB: www.facebook.com/beeteco
Email: contact@beeteco.com
Tel: 0650 3617 012
Hotline: 0909.41.61.43
A Comparison of Contemporary Electrical Distribution Equipment Standardsmichaeljmack
1) Electrical distribution equipment standards define performance characteristics under worst-case conditions and allow for objective comparison of equipment from different vendors.
2) Standards like UL 1558 and UL 1066 require more rigorous testing, including short circuit and heat rise tests, compared to UL 891, allowing for selective coordination while maintaining arc flash protection.
3) While UL 1558 equipment is generally more expensive, UL 891 equipment using UL 1066 breakers can also maintain selectivity in many applications if specific standards requirements are met. The appropriate standard depends on the unique needs of each installation.
Far series outdoor auto circuit recloserAUTO RECLOSER
The document provides information on the FAR series pole mounted auto circuit recloser from Zhejiang Farady Electric Co., Ltd. Key details include:
- It uses epoxy resin solid insulation and a long life magnetic actuator, and integrates functions of control, protection, measurement, communication, fault detection and online monitoring.
- It is suitable for overhead distribution lines and substations from 11kV to 38kV. Rated currents range from 200A to 1600A and breaking capacities are from 12.5kA to 31.5kA.
- It has optional communication protocols, measurement functions, reclosing intervals and event recording capabilities.
Split system with R410a gas and condensation control, consisting of an outdoor unit and an Low-head Ducted or High-head Ducted (horizontal installation) indoor unit. The outdoor unit uses DC inverter technology on both the fans and the compressors. The compressors are rotary. System operation is managed via microprocessor adjustment on non-polarised serial in CAN BUS protocol. The wired panel and infrared remote control are always supplied as standard with the indoor unit. A WRCS wired panel with integrated external contact is also available.
SenseTek is de specialist op het gebied van bijzondere branddetectie. Waar de mogelijkheden van reguliere detectiesystemen ophouden, beginnen de mogelijkheden van onze systemen. SenseTek Fire & Security Solutions Amsterdam. Handboek voor de installateur van beam detectie. Fireray 3000.
Different kinds of signals used in the DCSAjit Kumar
The document discusses different types of signals used in distributed control systems, including analog input (AI), analog output (AO), digital input (DI), and digital output (DO) signals. It also describes resistance temperature detectors (RTDs) and thermocouples (TCs), explaining their advantages and disadvantages. Finally, it lists the specific signal types used to control motors, motor operated valves, pneumatic valves, and solenoid valves.
CUM223 253 endress+hauser datasheet-turbidity and suspended solids transmitterENVIMART
The Liquisys M CUM223/253 is a modular turbidity and suspended solids transmitter with the following key features:
1) It has a modular design that allows for easy adaptation to customer requirements through additional software and hardware modules.
2) The basic version measures turbidity and suspended solids with configurable alarms, while extended versions add features like additional contacts, automatic cleaning, and communication protocols.
3) Applications include wastewater treatment, water treatment, and surface water monitoring in industries like sewage plants.
The SIMATIC S7-1200 CPU 1211C is a compact CPU with 6 digital inputs, 4 digital outputs, and 2 analog inputs. It has 30KB of program/data memory and operates on a supply voltage of 20.4-28.8V DC. The onboard I/O capabilities and power requirements allow for simple automation applications.
The 212 Heat Calculator is designed to measure the energy consumed in hot water heating systems and chilled water
cooling systems. The 212 will interface with a wide range
of flowmeters, including vortex and magnetic flowmeters with pulse outputs, positive displacement and inferential water meters, turbine and paddle wheel flowmeters.
This document provides a procedure for commissioning a drum water level indicator at an NTPC power plant. It details the plant details, objectives, proposal, required services, safety precautions, emergency procedures, current state of the plant, commissioning method, and completion criteria. The commissioning involves slowly charging the pressure vessel, comparing the indicator readings to other instruments, and releasing it for operation once commissioned on both sides of the drum.
The eDrive 150 BLDC motor controller provides advanced control of BLDC, PMSM, and induction motors up to 8 kW at 48 V. It supports various position sensors and motor control features including vector control, regenerative braking, and integrated protection functions. The controller communicates over CANOpen and has configurable parameters, settings, and functions via GUI software. It is designed for automotive applications with EMC protection in a IP54 rated aluminum housing.
Summary
1. ON Semiconductor has solutions for all low power offline driver topologies: Flyback, Buck-Boost, Buck-Boost, Linear
2. Primary Side Control approach optimized for tight accuracy and wide Vf support for high production yield and reduced development time
3. General shift in market to address non-isolated topologies
The document provides instructions for connecting and operating the control circuit of a KEB COMBIVERT F5 frequency inverter. It describes the terminal strip assignments and connections for the digital and analog inputs and outputs as well as the relay outputs. It also outlines how to operate the inverter using the control panel, including navigating menus, making parameter adjustments, and driving the motor in forward and reverse. Safety notices and pictograms used in the manual are also defined.
This document provides specifications for an EtherCAT servo drive called the REL. It can operate in various control modes including position, velocity, and torque control. It communicates via EtherCAT and has inputs and outputs including digital and analog I/O. It supports various feedback devices including encoders. Safety features include redundant enable inputs and overvoltage and overtemperature protection.
The emDrive H300 is an advanced motor controller that supports BLDC, PMSM, and induction motors up to 120kW continuous power. It uses vector current control for smooth torque and noiseless operation. It has extensive protection functions, configurable settings, and interfaces for position sensors, communications, and motor control.
This document discusses medium and high power LED drivers. It provides information on:
1) Medium and high power LED drivers can power a broad range from 20W to 400W and replace HID or fluorescent fixtures. They often use multiple power conversion stages tailored to the application needs and LED configuration.
2) Intelligent lighting controls that allow dimming can reduce energy costs and improve the payback time for LED solutions compared to initial purchase price and maintenance costs. Sensors and communication enable autonomous or networked control.
3) Bilevel lighting is an example of an intelligent lighting application, where discrete dimming levels tied to motion or activity provide significant energy savings compared to full brightness.
Low no-load power
Data Acquisition Equipment for Automation and Process ControlMiller Energy, Inc.
Power generation, process automation, and factory automation in manufacturing industries require rigorous, continuous monitoring in the control room. Yokogawa's DX series recorders are purpose-built data acquisition systems designed for industrial automation.
TMEIC MVG 2 Medium Voltage Drive up to 19,500 KVA at 11 kvDavid Batts
High Reliability, Energy Efficiency, Lower Harmonic Distortion, Local Sales ,Service, & Technical Support, 20 + year Capacitor life, bump less , make-before-break transfer
The document describes a pole mounted auto circuit recloser manufactured by Zhejiang Farady Electric Co., Ltd. The FAR series recloser can be used on overhead distribution lines and substations from 11kV to 38kV. It integrates control, protection, measurement, communication, fault detection and online monitoring functions. Key features include epoxy resin solid insulation, a magnetic actuator, and recloser functions. It is designed to perform reliably for over 20 years in various environmental conditions.
Catalog biến tần Frenic eHVAC - beeteco.com
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Địa chỉ : Số 7/31 KDC Thương Mại Sóng Thần, KP. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Tỉnh Bình Dương
FB: www.facebook.com/beeteco
Email: contact@beeteco.com
Tel: 0650 3617 012
Hotline: 0909.41.61.43
A Comparison of Contemporary Electrical Distribution Equipment Standardsmichaeljmack
1) Electrical distribution equipment standards define performance characteristics under worst-case conditions and allow for objective comparison of equipment from different vendors.
2) Standards like UL 1558 and UL 1066 require more rigorous testing, including short circuit and heat rise tests, compared to UL 891, allowing for selective coordination while maintaining arc flash protection.
3) While UL 1558 equipment is generally more expensive, UL 891 equipment using UL 1066 breakers can also maintain selectivity in many applications if specific standards requirements are met. The appropriate standard depends on the unique needs of each installation.
Far series outdoor auto circuit recloserAUTO RECLOSER
The document provides information on the FAR series pole mounted auto circuit recloser from Zhejiang Farady Electric Co., Ltd. Key details include:
- It uses epoxy resin solid insulation and a long life magnetic actuator, and integrates functions of control, protection, measurement, communication, fault detection and online monitoring.
- It is suitable for overhead distribution lines and substations from 11kV to 38kV. Rated currents range from 200A to 1600A and breaking capacities are from 12.5kA to 31.5kA.
- It has optional communication protocols, measurement functions, reclosing intervals and event recording capabilities.
Split system with R410a gas and condensation control, consisting of an outdoor unit and an Low-head Ducted or High-head Ducted (horizontal installation) indoor unit. The outdoor unit uses DC inverter technology on both the fans and the compressors. The compressors are rotary. System operation is managed via microprocessor adjustment on non-polarised serial in CAN BUS protocol. The wired panel and infrared remote control are always supplied as standard with the indoor unit. A WRCS wired panel with integrated external contact is also available.
SenseTek is de specialist op het gebied van bijzondere branddetectie. Waar de mogelijkheden van reguliere detectiesystemen ophouden, beginnen de mogelijkheden van onze systemen. SenseTek Fire & Security Solutions Amsterdam. Handboek voor de installateur van beam detectie. Fireray 3000.
Different kinds of signals used in the DCSAjit Kumar
The document discusses different types of signals used in distributed control systems, including analog input (AI), analog output (AO), digital input (DI), and digital output (DO) signals. It also describes resistance temperature detectors (RTDs) and thermocouples (TCs), explaining their advantages and disadvantages. Finally, it lists the specific signal types used to control motors, motor operated valves, pneumatic valves, and solenoid valves.
CUM223 253 endress+hauser datasheet-turbidity and suspended solids transmitterENVIMART
The Liquisys M CUM223/253 is a modular turbidity and suspended solids transmitter with the following key features:
1) It has a modular design that allows for easy adaptation to customer requirements through additional software and hardware modules.
2) The basic version measures turbidity and suspended solids with configurable alarms, while extended versions add features like additional contacts, automatic cleaning, and communication protocols.
3) Applications include wastewater treatment, water treatment, and surface water monitoring in industries like sewage plants.
The SIMATIC S7-1200 CPU 1211C is a compact CPU with 6 digital inputs, 4 digital outputs, and 2 analog inputs. It has 30KB of program/data memory and operates on a supply voltage of 20.4-28.8V DC. The onboard I/O capabilities and power requirements allow for simple automation applications.
The 212 Heat Calculator is designed to measure the energy consumed in hot water heating systems and chilled water
cooling systems. The 212 will interface with a wide range
of flowmeters, including vortex and magnetic flowmeters with pulse outputs, positive displacement and inferential water meters, turbine and paddle wheel flowmeters.
This document provides a procedure for commissioning a drum water level indicator at an NTPC power plant. It details the plant details, objectives, proposal, required services, safety precautions, emergency procedures, current state of the plant, commissioning method, and completion criteria. The commissioning involves slowly charging the pressure vessel, comparing the indicator readings to other instruments, and releasing it for operation once commissioned on both sides of the drum.
The eDrive 150 BLDC motor controller provides advanced control of BLDC, PMSM, and induction motors up to 8 kW at 48 V. It supports various position sensors and motor control features including vector control, regenerative braking, and integrated protection functions. The controller communicates over CANOpen and has configurable parameters, settings, and functions via GUI software. It is designed for automotive applications with EMC protection in a IP54 rated aluminum housing.
Summary
1. ON Semiconductor has solutions for all low power offline driver topologies: Flyback, Buck-Boost, Buck-Boost, Linear
2. Primary Side Control approach optimized for tight accuracy and wide Vf support for high production yield and reduced development time
3. General shift in market to address non-isolated topologies
The document provides instructions for connecting and operating the control circuit of a KEB COMBIVERT F5 frequency inverter. It describes the terminal strip assignments and connections for the digital and analog inputs and outputs as well as the relay outputs. It also outlines how to operate the inverter using the control panel, including navigating menus, making parameter adjustments, and driving the motor in forward and reverse. Safety notices and pictograms used in the manual are also defined.
This document provides specifications for an EtherCAT servo drive called the REL. It can operate in various control modes including position, velocity, and torque control. It communicates via EtherCAT and has inputs and outputs including digital and analog I/O. It supports various feedback devices including encoders. Safety features include redundant enable inputs and overvoltage and overtemperature protection.
The emDrive H300 is an advanced motor controller that supports BLDC, PMSM, and induction motors up to 120kW continuous power. It uses vector current control for smooth torque and noiseless operation. It has extensive protection functions, configurable settings, and interfaces for position sensors, communications, and motor control.
This document discusses medium and high power LED drivers. It provides information on:
1) Medium and high power LED drivers can power a broad range from 20W to 400W and replace HID or fluorescent fixtures. They often use multiple power conversion stages tailored to the application needs and LED configuration.
2) Intelligent lighting controls that allow dimming can reduce energy costs and improve the payback time for LED solutions compared to initial purchase price and maintenance costs. Sensors and communication enable autonomous or networked control.
3) Bilevel lighting is an example of an intelligent lighting application, where discrete dimming levels tied to motion or activity provide significant energy savings compared to full brightness.
Low no-load power
Data Acquisition Equipment for Automation and Process ControlMiller Energy, Inc.
Power generation, process automation, and factory automation in manufacturing industries require rigorous, continuous monitoring in the control room. Yokogawa's DX series recorders are purpose-built data acquisition systems designed for industrial automation.
TMEIC MVG 2 Medium Voltage Drive up to 19,500 KVA at 11 kvDavid Batts
High Reliability, Energy Efficiency, Lower Harmonic Distortion, Local Sales ,Service, & Technical Support, 20 + year Capacitor life, bump less , make-before-break transfer
The document describes a pole mounted auto circuit recloser manufactured by Zhejiang Farady Electric Co., Ltd. The FAR series recloser can be used on overhead distribution lines and substations from 11kV to 38kV. It integrates control, protection, measurement, communication, fault detection and online monitoring functions. Key features include epoxy resin solid insulation, a magnetic actuator, and recloser functions. It is designed to perform reliably for over 20 years in various environmental conditions.
The Eaton Automatic Transfer Switch (ATS-PWR) monitors mains power for abnormalities and automatically starts a generator to provide backup power if issues are detected. It then switches the load to the generator. When mains power is restored, it returns the load to mains and stops the generator. The ATS-PWR offers benefits like remote monitoring, history logging for troubleshooting, and communication interfaces. It can be configured for standby generator applications to provide automatic backup power in the event of a mains failure.
The Eaton Automatic Transfer Switch (ATS-PWR) monitors mains power for abnormalities and automatically starts a generator to provide backup power if issues are detected. It then switches the load to the generator. When mains power is restored, it returns the load to mains and stops the generator. The ATS-PWR offers benefits like remote monitoring, history logging for troubleshooting, and configurable transfer settings. It can be used for standby generator applications to provide backup power in the event of a mains failure.
The document provides information on the SPAJ 110 C earth-fault relay:
1) The relay has two protection stages, a low-set and high-set neutral overcurrent stage, and can be used for primary or back-up earth-fault protection on power systems.
2) Key features include definite time and inverse time operation for the low-set stage, self-diagnostics, serial communication interface, and flexible configuration of protection and output functions.
3) The relay measures earth fault current via current transformers and provides trip and alarm outputs when fault thresholds are exceeded.
Staco Energy Products Company is a 75+ year old privately held manufacturer of voltage control and power quality products based in Dayton, Ohio. They provide tailored power solutions to targeted markets such as water/wastewater treatment, education, and manufacturing. Their FirstLine P UPS systems range in size from 65kVA to 250kVA and utilize double conversion technology with features such as hot swap capability, digital control, and parallel capabilities. The systems include components such as rectifiers, chargers, switches, and can be configured with external battery cabinets.
The document discusses a high-end multi-functional electronic load called the Load Station Series (300W/1000W). It has several key features:
1) It can precisely set current waveforms on a color LCD and has dynamic, sequence, and sweep modes for testing.
2) It has a high-speed current control technology that eliminates overshoot and delivers a smooth current transition.
3) Unlike conventional loads, it acts as a resistive load from 0V so there is no delay between current and voltage, allowing it to test low-voltage devices.
4) It has options like a ripple and noise measurement module, can be remotely controlled, and its units can be connected in
This document summarizes the features of the KG Load Station Series 300W/1000W electronic loads. It has a revolutionary UI like an oscilloscope for easy operation. It realizes less 35% weight than previous models. It can operate just like a resistor with no minimum voltage requirement. It has high speed current control and 4 models from 300W to 1000W in 125V and 500V ranges.
The document discusses a high-end multi-functional electronic load called the Load Station Series (300W/1000W). It has several key features:
1) It can precisely set current waveforms on a color LCD and has a revolutionary oscilloscope-like user interface for ease of operation.
2) It has high-speed current control technology that eliminates overshoot and delivers an ideal current shape.
3) It offers flexible operation modes including constant current, constant resistance, constant power, constant voltage, external control, and sequence mode. Accessories like a ripple and noise measurement module are also available.
4) The lightweight and compact design incorporates a large LCD, memory functions, multi-
The document provides an overview of variable frequency drive (VFD) basics, including:
- The main components of a VFD are the converter section, which converts AC to DC, the DC bus section, which stores the DC voltage, and the inverter section, which converts the DC back to variable frequency AC to control motor speed.
- Pulse width modulation (PWM) is used to vary the width of output voltage pulses to adjust motor speed and torque.
- A VFD allows controlling motor torque at all speeds to meet application needs, unlike direct AC connection which is limited to a fixed speed-torque curve.
- Proper sizing and installation of input and output components like contactors
Bộ điều khiển nhiệt độ (Temperature Controller) Fuji Electric PXF4CTY TNHH HẠO PHƯƠNG
Fuji Electric sẽ thay đổi mã hàng Bộ điều khiển nhiệt độ Fuji Electric (Temperature Controller), sản phẩm thuộc họ Fuji Instrument với các dòng PXR4/5/9
The Fortress Series Tower is a 3 phase, 208V, parallel capable, fully redundant, true online, double-conversion UPS features a small footprint cabinet, built in batteries, DSP control, programmable bat tery voltage.
This document provides information on Fluke clamp meters for various applications. It describes the job functions and applications for different types of electricians and maintenance professionals. For each job function, it recommends certain Fluke clamp meter models based on their key features. It provides specifications for different clamp meter models to help users select the right one for their needs. In the last section, it compares the features of the clamp meter models in a table for easy reference.
The document provides an overview of variable frequency drive (VFD) basics, including:
- The main components of a VFD are the converter section, which converts AC to DC, the DC bus section, which stores the DC voltage, and the inverter section, which converts the DC back to variable frequency AC to control motor speed.
- Pulse width modulation (PWM) is used to vary the width of output voltage pulses to adjust motor voltage and frequency.
- A VFD allows controlling motor torque across the entire speed range.
- Topics like input current sizing, single phase operation, overload protection, and enclosure ratings are also discussed.
Bộ lưu điện ups gtec chính hãng Italia được cung cấp và phân phối độc quyền tại Việt Nam bởi Công ty TNHH Kỹ Thuật VBS. Hiện nay Bộ lưu điện ups đang chiếm lĩnh thị trường nguồn điện dự phòng tại việt nam trong thời kỳ công nghệ 4.0.
https://ups-gtec.com/
The document provides an overview of National Semiconductor's LM315x Synchronous Simple Switcher® Controller Series. The controllers feature constant on-time control, wide input voltage range from 6V to 42V, adjustable output voltage down to 0.6V, and up to 95% peak efficiency. A simplified block diagram shows the basic hysteretic control scheme. Design examples demonstrate how to select components like MOSFETs, inductors, and capacitors to design a power supply circuit using the LM315x controllers. Evaluation boards are available to test designs with switching frequencies up to 1MHz and output currents up to 10A.
buy old yahoo accounts buy yahoo accountsSusan Laney
As a business owner, I understand the importance of having a strong online presence and leveraging various digital platforms to reach and engage with your target audience. One often overlooked yet highly valuable asset in this regard is the humble Yahoo account. While many may perceive Yahoo as a relic of the past, the truth is that these accounts still hold immense potential for businesses of all sizes.
Taurus Zodiac Sign: Unveiling the Traits, Dates, and Horoscope Insights of th...my Pandit
Dive into the steadfast world of the Taurus Zodiac Sign. Discover the grounded, stable, and logical nature of Taurus individuals, and explore their key personality traits, important dates, and horoscope insights. Learn how the determination and patience of the Taurus sign make them the rock-steady achievers and anchors of the zodiac.
At Techbox Square, in Singapore, we're not just creative web designers and developers, we're the driving force behind your brand identity. Contact us today.
Top mailing list providers in the USA.pptxJeremyPeirce1
Discover the top mailing list providers in the USA, offering targeted lists, segmentation, and analytics to optimize your marketing campaigns and drive engagement.
LA HUG - Video Testimonials with Chynna Morgan - June 2024Lital Barkan
Have you ever heard that user-generated content or video testimonials can take your brand to the next level? We will explore how you can effectively use video testimonials to leverage and boost your sales, content strategy, and increase your CRM data.🤯
We will dig deeper into:
1. How to capture video testimonials that convert from your audience 🎥
2. How to leverage your testimonials to boost your sales 💲
3. How you can capture more CRM data to understand your audience better through video testimonials. 📊
Best practices for project execution and deliveryCLIVE MINCHIN
A select set of project management best practices to keep your project on-track, on-cost and aligned to scope. Many firms have don't have the necessary skills, diligence, methods and oversight of their projects; this leads to slippage, higher costs and longer timeframes. Often firms have a history of projects that simply failed to move the needle. These best practices will help your firm avoid these pitfalls but they require fortitude to apply.
Recruiting in the Digital Age: A Social Media MasterclassLuanWise
In this masterclass, presented at the Global HR Summit on 5th June 2024, Luan Wise explored the essential features of social media platforms that support talent acquisition, including LinkedIn, Facebook, Instagram, X (formerly Twitter) and TikTok.
Unveiling the Dynamic Personalities, Key Dates, and Horoscope Insights: Gemin...my Pandit
Explore the fascinating world of the Gemini Zodiac Sign. Discover the unique personality traits, key dates, and horoscope insights of Gemini individuals. Learn how their sociable, communicative nature and boundless curiosity make them the dynamic explorers of the zodiac. Dive into the duality of the Gemini sign and understand their intellectual and adventurous spirit.
Navigating the world of forex trading can be challenging, especially for beginners. To help you make an informed decision, we have comprehensively compared the best forex brokers in India for 2024. This article, reviewed by Top Forex Brokers Review, will cover featured award winners, the best forex brokers, featured offers, the best copy trading platforms, the best forex brokers for beginners, the best MetaTrader brokers, and recently updated reviews. We will focus on FP Markets, Black Bull, EightCap, IC Markets, and Octa.
2. • •Subjected to rigorous and strict quality controls at every stage of manufacturing Designed to meet latest national
international standards like BIS, IS, IEC, ANSI, BS, DIN, etc. Wide range of Transformers duly tested at Central Power Research•
Institute, Bangalore , Bhopal Quality assurance programme available
• Off-circuit tap changer to provide +5% to -5% in steps of
2.5% (or as specified by customer)
• On-load tap changer to provide +5% to -15% in steps of
1.25% (or as specified by customer)
• 3 Phase, 50 Hz in voltages of 11 KV, 22 KV and 33 KV
• Continuous duty
• Painting as per IS / IEC standards
• Vector group Dyn 11
• Standard fittings as per IS: 2026 / IEC 76 / BIS 1180
• HV side cable box/Bare Bushings
• LV side cable box / bus duct
• Design conforms to BIS 1180 & IS:2026, BS 171, IEC 76 and
other relevant standards
• Latest manufacturing techniques to ensure cost
effectiveness and reliability
• Designed for 25 years of trouble - free performance
• Very low power loss and low noise
• Optimum utilization of active materials for sleek design
• Withstands electrical impulses, thermal and dynamic
stresses
Technical Specifications
Salient Features
• • •Tube Mills Telecom Centers Rice Mills
• •Rolling Plants Educational Institutions
• • •Cold Storage Clubs Pharmaceuticals Units
• •Residential & Commercial Food Processing Units
... and many more.
Most Suitable for
• •Subjected to rigorous and strict quality controls at every stage of manufacturing Designed to meet latest national
international standards like BIS, IS, IEC, ANSI, BS, DIN, etc. Wide range of Transformers duly tested at Central Power Research•
Institute, Bangalore , Bhopal Quality assurance programme available
• Off-circuit tap changer to provide +5% to -5%, +7.5% to -
7.5% , +10% to -10% taps
• On-load tap changer to provide +5% to -15% taps in
steps of 1.25% / +5% to - 15% in steps of 2.5%
• 3 Phase, 50 Hz in voltages of 11 KV, 22 KV and 33 KV
• Continuous duty
• Painting as per IS / IEC standards
• Vector group Dyn 11 ( or ) as required
• Standard fittings as per IS: 2026 / IEC 76
• HV side cable box/Bare Bushings
• LV side cable box / bus duct
Technical Specifications
TM
Medium & Small Power Transformers
Distribution Transformers
Capacities Available upto 16 MVA
• Design conforms to IS:2026, BS 171, IEC 76 and other
relevant standards
• Latest manufacturing techniques to ensure cost
effectiveness and reliability
• Designed for 25 years of trouble - free performance
• Very low power loss and low noise
• Optimum utilization of active materials for sleek design
• Withstands electrical impulses, thermal and dynamic
stresses
Salient Features
All DISCOMS Substations
Most Suitable for
* Inverter duty Transformer for Solar &
Wind Power Generation Application
Capacities Available upto 3150 KVA
3. Provides perfectly stable output even under severe conditions of unbalanced voltage
conditions. Ideal to protect the electrical and electronic equipments from high and low
voltage.
Protections
• Single Phasing Prevention
• Output Electronic Over Load Protection
• Phase Reversal Protection
• Input Short Circuit Protection with MCB
• Input Over Load Protection with MCB
• Output Low Voltage Protection
• Output High Voltage Protection
• Audio Alarm for Protections
Indications
• Mains Input on 3 LED Indications,
• 3ph output on indication
• Phase Reversal indication
• over Load indication
Indications in LCD Display
• Input High and Input low
• Output on indication
• Output high Cutoff and Output Low Cutoff
Technical Specifications
Input Voltage Range : 300 - 460V / 340 - 480V / 360 - 460V
AC 3 Ph
Output Voltage (3 Ph) : 415V AC
System : Unbalanced 4 wire: R Y B N
Connections : Star
Operating Frequency : 47 to 53 Hz
Output Voltage Adjustable : 380 to 415V AC in 3 Ph
Output Voltage Regulation : + 1% (No Load)
Output Voltage Regulation : + 1% (Full Load)
Overload Capacity : 120%
Correction Rate : 60 / 30 / 25V per Sec-3 Phase
Waveform Distortion : Nil
Output Waveform : True Reproduction of Input
Insulation : Class F
Short Circuit period &
Percentage : 300% for 250 Milli Sec.
0 0
Normal Operation Temperature : 0 C to 45 C
0
Climate Conditions : 90% Rh Max. Non Condensing at 35 C
Type of Cooling : Natural air cooled up to 600 KVA
Mode of system : Fully Automatic
System Construction : As per IS : 9815 – 1994
Servo Controlled Voltage Stabilizer 3 Phase Air Cooled Capacity Range upto 600 kVA 3 Ph
• Quick response time 10 milli sec (half a cycle)
• Very high efficiency above 98%
• Excellent regulation as high as +/- 0.5%
• “Micro controller” controlled system
• Wide input range of operations & high speed of correction
Salient Features
TM
TM
600KVA 3Ph
Metering On LCD Display
• 3ph Input voltage ph to ph and ph to Neutral
• 3ph Output voltage ph to ph and ph to Neutral
• System Frequency
• Output Current on each ph
Programmable Control Timings
• Over load Cutoff Time
• Auto Restart Time
• On & Off Delay Time
Programmable Parameters
• Output voltage set ( 210-245V)
• Output Low Voltage Cutoff
• Output High Voltage Cutoff
• Input Low on LCD Display
• Input High on LCD Display
• Sensitivity / Regulation
• Over Load Cutoff
• CT full scale
Programmable Controls
• Display Scrolling -
Auto / Manual
• Start / Stop Buttons
Optional Out Door Available
Menu / Start / Stop / Reset
/ Log Button
Data Log: Last 100 fault events
log with Date & Time stamp
and works on FIFO basis.
Very Important For CSD
Analysis Problems
4. Provides perfectly stable output even under severe conditions of unbalanced voltage conditions. Ideal to protect
the electrical and electronic equipments from high and low voltage.
Technical Specifications
Input Voltage Range : 300 - 460V / 340 - 480V / 360 - 460V
AC 3 Ph
Output Voltage (3 Ph) : 415V AC
System : Unbalanced 4 wire: R Y B N
Connections : Star
Operating Frequency : 47 to 53 Hz
Output Voltage Adjustable : 380 to 415V AC in 3 Ph
Output Voltage Regulation : + 1% (No Load)
Output Voltage Regulation : + 1% (Full Load)
Overload Capacity : 120%
Correction Rate : 60 / 25 / 15V per Sec-3 Phase
Waveform Distortion : Nil
Output Waveform : True Reproduction of Input
Insulation : Class B
Short Circuit period &
Percentage : 300% for 250 Milli Sec.
0 0
Normal Operation Temperature : 0 C to 45 C
0
Climate Conditions : 90% Rh Max. Non Condensing at 35 C
Type of Cooling : Natural Oil cooled up to 5000 KVA
Mode of system : Fully Automatic
System Construction : As per IS : 9815 – 1994
Protections
• Single Phasing Prevention
• Output Electronic Over Load Protection
• Phase Reversal Protection
• Input Short Circuit Protection with MCB
• Input Over Load Protection with MCB
• Output Low Voltage Protection
• Output High Voltage Protection
• Audio Alarm for Protections
Indications
• Mains Input on 3 LED Indications,
• 3ph output on indication
• Phase Reversal indication
• over Load indication
Indications in LCD Display
• Input lowInput High and
• Output on indication
• Output high Cutoff and Output Low
Cutoff
Servo Controlled Voltage Stabilizer 3 Phase Oil Cooled Capacity Range upto 5000 kVA 3 Ph
Metering On LCD Display
• 3ph Input voltage ph to ph and ph to Neutral
• voltage ph to ph and ph to Neutral3ph Output
• System Frequency
• Output Current on each ph
• Quick response time 10 milli sec (half a cycle)
• Very high efficiency above 98%
• Excellent regulation as high as +/- 0.5%
• “Micro controller” controlled system
• Wide input range of operations & high speed of correction
Salient Features
Programmable Control Timings
• Over load Cutoff Time
• Auto Restart Time
• On & Off Delay Time
Programmable Parameters
• Output voltage set ( 210-245V)
• Output Low Voltage Cutoff
• Output High Voltage Cutoff
• Input Low on LCD Display
• Input High on LCD Display
• Sensitivity / Regulation
• Over Load Cutoff
• CT full scale
Programmable Controls
• Display Scrolling -
Auto / Manual
• Start / Stop Buttons
Optional Out Door Available
Menu / Start / Stop / Reset
/ Log Button
Data Log: Last 100 fault events
log with Date & Time stamp
and works on FIFO basis.
Very Important For CSD
Analysis Problems
5. With Very High Speed of Correction provides perfectly stable output even under severe conditions of unbalanced voltage
conditions. Ideal to protect the electrical and electronic equipments from high and low voltage.
Metering
• 3ph Input volt meter to read ph
to ph and ph to Neutral
Voltages at Input & Output with
selector switch
• 3ph Ammeter to read Output
Current on each ph
• IGBT PWM AC to AC Switching control
• Individual Phase control
• Quick response time <10 milli sec (half a cycle)
• Very high efficiency above 98%
• Excellent regulation as high as +/- 0.5%
• Wide input range of operations
• Very high speed of correction 3000V per Second
Salient Features
Protections
• Input Short Circuit Protection with MCB
• Input Over Load Protection with MCB
• Output Low Voltage Protection
• Output High Voltage Protection
• Single Phase preventer
• Output Electronic Over Load Protection
Input Voltage Range : 300 - 460V / 340 - 480V / 360 - 460V AC 3 Ph
Output Voltage (3 Ph) : 415V AC
Operating Freequency : 47 - 53 Hz
Indications
Mains on Indication on each
phase 3 LEDs
3 Phase Output on Indiacation
Technical Specification
Servo Voltage Stabilizers come in a wide range of models. The
standard 3-phase models are suitable for balanced &
unbalanced supply/loads, which conform to the following
specifications:
Input Voltage Range : 360-460V, 340-480V, & 300-460 V
Output Voltage : 415 V 1%, 3-Phase, 50 Hz+
Efficiency (approx) : 99.5%, 99%, 98.7%, 98.5%
Cooling : Oil Cooled
Type : Indoor / Outdoor
0
Temperature Rise : 40 C above ambient
Mounting On : Uni-directional Wheels
Corrections Rate : 8-12 V/Sec.(Up to 500KVA),
6-8 V/Sec (500 to 1000 KVA) &
4-5V/Sec (Above 1000 KVA)
Wave form distortion : Nil
Duty Cycle : 100% Continuous
TM
Linear Automatic Voltage Stabilizer Capacity Range upto 5000 kVA & above, 3 Ph
• Negligible losses in full boost & buck condition
• Suitable for continuous 100 % duty cycle Linear type Vertical
Rolling Contact regulator
• Lowest power consumption on no load - 0.5 % to 1 %
• Life of Stabilizer at full load is 15-20 years
• Double wound Buck / Boost Transformer
• Electronic Control Circuit and Metering panel
• Rugged and Robust Design Technology
Advantages
• 60% Depreciation as per Income Tax Act
• •Reduces Global Warming Higher Productivity
• •Reduction in MDI Uniform Quality of End Product
• •Low Maintenance Cost Reduction in breakdown
of electrical equipments High Energy Savings•
• • •Cement Plants Air Ports Rolling Plants
• • •Flour Mills Engineering Units Cell Phone
Networks Rice Mills Pharmaceutical Units• •
• Cold Storage
Most Suitable for
Cost of Automatic Voltage Stabilizer can we
recovered in 2 to 3 Years
StaticVoltage Stabilizer Capacity Range upto 150 kVA 3 Ph
6. Programmable Control Timings
• Over load Cutoff Time
• Auto Restart Time
• On & Off Delay Time
Optional Out Door Available
Provides perfectly stable output even under severe conditions of unbalanced voltage
conditions. Ideal to protect the electrical and electronic equipments from high and low
voltage.
• Individual Phase control
• By pass provision
• Suitable for individual phase
applications
• Quick response time 10 milli sec (half a
cycle)
• Very high efficiency above 98%
• Excellent regulation as high as +/- 0.5%
• “Micro controller” controlled system
• Wide input range of operations & high
speed of correction
• Also offering Static Voltage Stabilizers on
customer’s demand
Salient Features
Protections
• Input Short Circuit Protection with MCB
• Input Over Load Protection with MCB
• Output Low Voltage Protection
• Output High Voltage Protection
• Output Electronic Over Load Protection
Input Voltage Range : 300 - 460V / 340 - 480V / 360 - 460V AC 3 Ph
Output Voltage (3 Ph) : 415V AC
Servo Controlled Voltage Stabilizer 3 Phase Residential Capacity Range upto 200 kVA 3 Ph
Programmable Parameters
• Output voltage set ( 210-245V)
• Output Low Voltage Cutoff
• Input High on LCD Display
• Sensitivity / Regulation
• Over Load Cutoff
• CT full scale
• Output High Voltage Cutoff
• Input Low on LCD Display
Metering On LCD Display
• 3ph Input volt meter to read ph to
ph and ph to Neutral Voltages
• 3ph Output volt meter to read ph to
ph and ph to Neutral Voltages
• Frequency meter to read system
Frequency
• 3ph Ammeter to read Output
Current on each ph
Servo Stabilizer (Single Phase) Capacity Range upto 25 KVA, 1 Ph
Input Voltage Range : 170-270V AC, 50 Hz
Output Voltage : 230V AC 50 Hz 1Phase
Operating Frequency : 47 to 53 Hz
Output regulation : + 1%
Correction Speed : 35V/sec
Line regulation : + 1%
Load regulation : + 1%
Wave-form distortion : Nil
Power factor effect : Nil
Output wave -form : True reproduction of Input
Type of cooling : Natural Air-cooled
System Construction : As per IS:9815
Efficiency : 98.5%
Response Time : 10 milli sec.
Servo Motor Drive : rugged ac step synchronous motor
Enclosure : IP32
Technical Specifications
Indication on Front Panel
• Input ON
• Output ON
• Output CUT-OFF
• Input LOW
• Input HIGH
• 0-300 V 72 Sq. mm analog meter to read output voltage
High voltage protection
Low voltage protection
Overload protection
Short circuit protection
Protections
} with Relay / Contactor
} with MCB
1 PH SCVS Dimensions (mm)
Input Connection
Output Connection
• 1 & 2 KVA - Sockets
• 3 KVA to10 KVA with Connectors
• Above 10 KVA nut & bolt termination
• •1 & 2 KVA - Power Card with Plug Top 3 KVA to10 KVA with Connectors
• Above 10 KVA nut & bolt termination
Capacity Width Depth Height Weight/kgs
1 KVA 280 310 300 16
2 KVA 280 310 300 18
3 KVA 300 430 300 28
5 KVA 300 430 300 33
7.5 KVA 360 470 310 55
10 KVA 360 470 310 60
15 KVA 440 470 800 100
7. Salient Features
• • •Uses solid state control circuits Synchronous motor drive No warm - up time
• •No relays Professional grade ICs and Components are used
High reliability
Trouble free operation
Technical Specifications
Input Voltage Range : 300 - 460V / 340 - 480V / 360 - 460V AC 3 Ph
Out put : 415 / 200V 3ph as per requirement
Insulation : class H
Speed of correction : 60 / 30 / 25V per Sec. with AC motor 105 V / Sec. with
DC motor
Response time : 10 milliseconds
System Connections : Delta / Star
Ratios : 1:1 and 2:1
Regulation : Better than 3.5 %
Power Factor : 0.75 Lead to 0.75 Lag
Di-electric Strength : 3KV for 60 sec
Insulation Resistance : Better than 1000 Mega Ohms
Coupling Capacitance : 0.01 PF for 100 Db
Leakage Current : Less than 20 Micro Amps
Common Mode Attenuation : 100 Db / 120 Db
Construction Standards : As per IS 2026 Part I & II
Type of Execution : Closed Type
0 0
Operating Temperature : 0 C to 45 C
Type of cooling : Natural air / Forced air
• CNC Machines
• Telecommunication Equipments
• Bio Medical Equipments
• Large Computer Installations
• •Printing Machinery Scientific
Equipments Cell Phone Networks•
• •Garment Equipments Textile
Machineries ... and many more.
Most Suitable for
• •Quick response time 10 milli sec (half a cycle) Efficiency, Low losses, Low
temperature rise and Withstands in all climatic conditions Provides perfectly stable•
output power even under sever conditions of voltage fluctuations Zero wave -•
form distortion Unaffected by load power factor Ruggedized construction• •
• • •Enclosure - IP32 Mounting - Floor Mounted / Free on Wheel Servo Motor
Drive - Rugged ac step synchronous motor
• Eliminates stresses that come from normal electrical transients
• Meet stringent clean power requirements of the sophisticated
/ sensitive equipments
• Reduces the effects of power line problems like Noise, Spikes,
Surges, Transients and Neutral to minimum
• •CNC Machines Bio Medical Equipments
• • •Printing Machineries Cell Phone Networks Scientific Equipments
• • •Textile Machineries Oil & Vanaspathi Plants Large Computer Installations
• Garment Equipments ... and many more.
System Connections : Delta / Star
Input Voltage : 415V 3 Phase
Output Voltage : 415V or 200V 3 Phase
Ratios : 1:1 and 2:1
Regulation : Better than 3.5 %
Power Factor : 0.75 Lead to 0.75 Lag
Di-electric Strength : 3KV for 60 sec
Insulation Resistance : Better than 1000Mega Ohms
Coupling Capacitance : 0.1 PF for 80 db
Leakage Current : Less than 20 Micro Amps
Common Mode Attenuation : 80 db / 100 db
Construction Standards : As per IS 2026 Part I & II, IS 11171
Type of Execution : Closed Type
0 0
Operating Temperature : 0 C to 45 C
Type of cooling : Natural air / Forced air
Oil cooled (optional)
Technical Specifications
Input Output Rating Available
415 V AC 3 Ph 415 V AC 3 Ph 3 KVA 3 Ph and
415 V AC 3 Ph 220 V AC 3 Ph upto1500 KVA 3Ph
230 V AC 1 Ph 230 V AC 1 Ph 1 KVA 1 Ph and
230 V AC 1 Ph 110 V AC 1 Ph upto 50 KVA 1 Ph
Most Suitable for
Power Conditioner Capacity Range upto 200 kVA 3 Ph
Isolation Transformer Capacity Range upto 1500 kVA 3 Ph
8. K-Rated Isolation Transformer is to deliver conditioned power to a nonlinear high-
harmonic current load and operate at safe temperatures while minimizing the
harmonic currents
In a data centre, all the distributed power loads are connected through a non
linear power source, due to which HARMONICS generation is unavoidable. These
generated Harmonics are flow back and directly effects the mains power source,
which a UPS. The effect of harmonics de-rates the capacity of UPS. Hence 100%
utilization of UPS capacity becomes wasted. The effect of harmonics also creates
much heat in the transformers of UPS.
To eliminate these direct effects on UPS, K-Factor Transformers are designed
based on the harmonics present the load. The special design of K-Factor
Transformer helps us to depend on much to eliminate or withstanding from the
effects of Harmonics.
Transformer
• Double wound , High Isolation
• Double sized neutral
• Insulation class “H”
• Regulation is better than 3.5%
• Overload rating of 100% for 10 secs
• Core of CRGO and conductor of copper
• Natural / Forced Air Cooled
• As per IS:2026 standards
• Attenuation: 80 db/100 db CMRR
• Primary connect as DELTA, secondary connection as STAR
• Efficiency of the transformer is minimum 98%
Technical Specifications
Input voltage : 415V 3 Phase Delta
Output Voltage : 415V 3 Phase Star
K-1, K-4, K-9, K-13, K-20
Isolation Transformer as per
customer requirement
• Eliminates stresses that come from normal electrical transients
• Meet stringent clean power requirements of the sophisticated /
sensitive equipments
• Reduces the effects of power line problems like Noise, Spikes,
Surges, Transients and Neutral to minimum
• •CNC Machines Bio Medical Equipments
• •Printing Machineries Cell Phone Networks
• •Scientific Equipments Textile Machineries
• •Oil & Vanaspathi Plants Large Computer Installations
• Garment Equipments ... and many more.
System Connections : Delta / Star
Input Voltage : 415V 3 Phase
Output Voltage : 415V or 200V 3 Phase
Ratios : 1:1 and 2:1
Regulation : Better than 3.5 %
Power Factor : 0.75 Lead to 0.75 Lag
Di-electric Strength : 3KV for 60 sec
Insulation Resistance : Better than 1000Mega Ohms
Coupling Capacitance : 0.01 PF for 100 db
Leakage Current : Less than 20 Micro Amps
Common Mode Attenuation : 100 db / 120 db
Construction Standards : As per IS 2026 Part I & II, IS 11171
Type of Execution : Closed Type
0 0
Operating Temperature : 0 C to 45 C
Type of cooling : Natural air / Forced air
Oil cooled (optional)
Technical Specifications
Most Suitable for
Ultra Isolation Transformer Capacity Range upto 1500 kVA, 3 Ph
Input Output Rating Available
415 V AC 3 Ph 415 V AC 3 Ph 3 KVA 3 Ph and
415 V AC 3 Ph 220 V AC 3 Ph upto1500 KVA 3Ph
230 V AC 1 Ph 230 V AC 1 Ph 1 KVA 1 Ph and
230 V AC 1 Ph 110 V AC 1 Ph upto 50 KVA 1 Ph
K-Rated Transformers Capacity Range upto1000 KVA, 3 Ph
9. System Connections : Star
Input Voltage : 415V 3 Phase
Output Voltage : 0 - 470V 3 Phase (Continuously Variable)
Power Factor : 0.75 Lead to 0.75 Lag
Di-electric Strength : 2.5KV for 60 sec
Insulation Resistance : Better than 100Mega Ohms
Construction Standards : As per IS 5142
Type of Execution : Closed Type
0 0
Operating Temperature : 0 C to 45 C
Type of cooling : Natural air / Oil cooled
Type of control : Motorised with Increase &
Decrease switches
Technical Specifications
Power distribution unit is fitted with multiple
outputs designed to distribute electrical
power.
In a data centre, all the distributed power
loads are connected through a non linear
power source, due to which HARMONICS
generation is unavoidable. These
generated Harmonics are flow back and
directly effects the mains power source,
which a UPS. The effect of harmonics de-
rates the capacity of UPS. Hence 100%
utilization of UPS capacity becomes wasted.
The effect of harmonics also creates much
heat in the transformers of UPS.
To eliminate these direct effects on UPS, K-
Factor Transformers are designed based on
the harmonics present the load. The special
design of K-Factor Transformer helps us to
depend on much to eliminate or
withstanding from the effects of Harmonics.
1 Transformer
• Double wound , High Isolation
• Double sized neutral
• Insulation class “H”
• Regulation is better than 3.5%
• Overload rating of 100% for 10 secs
• Core of CRGO and conductor of
copper
• Natural / Forced Air Cooled
• As per IS:2026 standards
• Attenuation: 80 db CMRR and 60 db
CMNR
• Primary connect as DELTA, secondary
connection as STAR
• Efficiency of the transformer is
minimum 98%
Technical Specifications
2 Power Distribution
• Floor mounting Panel board with MS
angles and Ms sheets with powder
coated Paint and suitable provisions
for cable
• Distributed outgoing through sub
branch breakers and branch breakers
• Extra sub breakers also provided
• Suitable capacity 3 pole incomer
3 Metering & Indications
• LED indications provided to
read the availability of
incoming supply
• Multi parameter reading
meter to read Voltages,
currents and power is
incorporated
Optional
Soft start facility BCPM
( Branch Circuit Power Monitoring)
Most suitable for
Data Centres, Telecom
TM TM
TM
TM
Power Distribution Unit with K-Rated Transformers Capacity Range upto 1000 KVA, 3 Ph
Auto Variable Transformers Capacity Range upto 2500A 3 Ph
10. Power Factor Controllers are designed
to operate, Automatically with Micro
Processor Based Automatic Controller
Use a specially designed electronic
control circuit that improves power
factor to meet requirements of load
switching pattern
Improvement of power factor up to
optimum levels is guaranteed
Product range: 20 KVAr to 1000 KVAr.
We provide solutions for improving
plant power factor by installing our
APFC panel
Heavy duty capacitors with detuned
filters will be provided where high level
non linear harmonies present upto 30%
• Payback period is 8 to 10 months
• Reduction in maximum demand
• Energy saving up to 5%
• Low power factor penalty can be avoided
• Extended life for Switch Gears, Capacitors and Cables
• Avoid manual disruptions
• Avoid high current consumption losses
• Reduction in Electricity Bill
Advantages
• All major components are of standard
make like Siemens, Epcos, L&T and
Schneider
• Microprocessor based automatic
controller with power factor display
• All components are carefully integrated
for reliable performance and longer life
• Capacitor duty Contactors and MCB or
MCCB, are used to switch ON capacitors
to minimize switching surges
• Uses small correction steps to maintain
accurate setting
• Auto / Manual Facility, Cooling Facility
• Very low watt losses
• In-built time delay for switching ON of a
capacitor bank to avoid impulse signal
operation. All capacitor feeders have
Auto / Manual mode facility with fuse
protection and isolation
Salient Features
• Manufacturing Companies
• •BPO Organizations Shopping Malls
• • •Steel Mills Spinning Mills Cement and Paper Mills
• •Offices & Buildings Hotel & Restaurants
• •Rice Mills Hospitals
• Cinema Halls / Multiplexes
Most Suitable for
Protections
• Overload with MCB / MCCB
• Manual Bypass provision arrangement
• Short Circuit with MCB / MCCB
• Spike, Surges & RF Suppressers
• Reduces heat generation in chokes,
ballast and prevents energy loss and
hazards
• We can also provide timing profile for
enhanced power savings
• Power savings above 20% in discharge
lighting.
• Uses imported, high quality raw
material to get high efficiency of 99.5%
• Reduction in MDI
• Improves life of all equipment
• Uses Isolation shielding to suppress the
harmonics and to give quality power to
load
• Reduces maintenance cost up to 80%
• Eligible for accelerated depreciation
benefit
• Pay back period is 8 to 12 months
based on the conditions and usage
Salient Features
Most Suitable for
• Street Lights / Security Lighting
• Telecom Buildings
• Sub-Station Buildings
• Work Shops
• Pump Houses
• Software Units / Call Centers
• Hotels and Restaurants
• Commercial Complexes
Food Processing units ..... and many more.
Power Saver Capacity Range upto 1000 kVA, 3 Ph
• Improves quality of power and
enhances life of electrical
gadgets
• Use latest technology to save
power by optimum supply of
power to various loads
• Employs reactive power
management system and
harmonics filtering system
consisting of electronic circuits,
special zig - zag inductors, hi-
tech R.C. Circuits and essential
switch gear systems
• Available in four models to suit
requirements like lighting, motors,
air conditioners and mixed loads
• Eliminates wastage of power in
electrical circuits caused by
super imposed power pollution
Panel Controls & Indications
• Input Three Phase POWER ON
• Digital energy meter
Automatic Power Factor Control Panel Capacity Range upto 1000 kVAR
11. Our clients are most concerned about power issues such as
power failure, power sag, power surge, under voltage or over
voltage, frequency variation, harmonic distortion and line
noise. Servomax emphasizes the areas of redundant power
supply, voltage regulation, equipment protection and
adjustment. Their power range, applications and the
equipment they protect are listed below:
Power Topology Applications
Lower than 1kVA Single-Phase Line-Interactive UPS PC and Peripherals
1 – 20kVA Single-Phase On-Line UPS Server and Network Equipment
10 – 400kVA Three-Phase On-Line UPS Datacenter and Industrial Equipment
20 – 800kVA Three-Phase modular On-Line UPS Modular Unit expansion and
Redundant power supply can be achieved
within a single rack
UPS systems feature the following
• Leading AC-AC Efficiency
• Fully redundant design and configuration
• High input and output power factors
• Easy expansion without additional hardware
• Supports to seamless operations at low level of TCO (Total Cost of Ownership)
• SMS facility for Energy Reading & Low Power Factor
• Earth fault relay
• Phase Sequence indication
Product Special Features
Most suitable for Industrial, Residential
Airport , Stadium
LT Panels
• Power Control Centres (PCC) Panels
• PMCC Panels
• Motor Control Centres (MCC) Panels
• Automatic Power Factor Control (APFC)
Panels
• Power Distribution Boards (PDB)
• Sub Distribution Boards
• Main Lighting Distribution Boards (MLDB)
• Sub Lighting Distribution Boards
• Control Desks
• Feeder Pillars
• Non – Segregated LT Busducts
Products
• L.V Switchboard
• As per IS Standards
• IP 52 / 54 / 55 protection
• Indoor / Outdoor
• Electrolytic Busbars Aluminium / Copper
• Customized Panels
• Single Front / Double Front / Dead Front
• DMC / SMC Insulators
• Capacity Expandable
• Complete Earthing of Doors & Frame
• Shipping sections as per demand
General Features
World No.1 Industry-leading energy efficiency UPS Systems from Servomax
12. SERVOMAX established in the year 1982. It is one of the largest manufacturer of Power
Conditioning and Power Saving equipment with advanced technologies.
SERVOMAX brand is synonymous with superior Quality, Reliability and Service - which is our main
focus. The above attributes have helped us in realizing customer satisfaction and loyalty.
SERVOMAX today has more than 50 thousand customers spread across the globe.
Our dedicated R&D team continuously strives towards upgrading products, technology and
providing new features to customers. We always deliver safe and reliable products.
SERVOMAX has a formidable customer list spanning various segments: Industries, Commercial
and Residential Complexes, Bio-medical units, R&D Labs, Textiles, Food & Beverages,
Educational Institutions, Hospitals and many more.
customercare@servomax.in
+91 911 1234567 1800 12 1111
+91 8100 12 1111
Toll Free:
www.servomax.in
TM
OUR PARTNERS
Sathya Solutions
Private Limited Electronics Pvt. Ltd.
THE LARGEST MANUFACTURING BASE IN INDIA WITH 20+ PRODUCTS IN
POWER SECTOR & MANUFACTURING SPACE ABOUT 2 LAC SFT
THE LARGEST CUSTOMER BASE IN INDIA & ABROAD
WITH THE LARGEST INSTALLATION NETWORK