SlideShare a Scribd company logo
1 of 9
Download to read offline
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 265 | P a g e
Sensitivity of Transient Phenomena Analysis of the Francis
Turbine Power Plants
Viktor Iliev*, Bojan Ivljanin**, Zoran Markov*, Predrag Popovski
*(Ss. Cyril and Methodius” University, Faculty of Mechanical Engineering – Skopje, Macedonia)
** (University of Belgrade, Faculty of Mechanical Engineering - Belgrade, Serbia)
ABSTRACT
The accurate definition of the transient phenomena of the hydroelectric power plant (HPP) and its units, taking
into account various aspects of operation is an essential requirement for design, performances and control of
HPPs. Numerical analysis of transient phenomena, such as increase of the rotational speed (runaway) of the
units, increase of the pressure (turbine inlet head) in the hydraulic system (water hammer) and water level
oscillation in the surge tank is presented. The results of transient phenomena analyses are relied upon for very
costly engineering decisions. Because of this, it is important that the researcher understands the effect unknown
modeling parameters on the result of transient analysis. Usually, different researchers may choose alternate
values for an unknown modeling parameter and this can have significant effects on the results. The main aim in
this paper is to investigate of the sensitivity of transient phenomena analysis with variation in modeling
parameters such as pipeline friction factor, wave speed, turbine guide vanes closing law, surge tank throttling
coefficient and generator inertia.
Keywords - Hydropower plant, transient phenomena, water hammer, runaway, sensitivity.
I. INTRODUCTION
Study the dynamic behavior of a hydropower
plant (HPP) is a necessary prerequisite for ensuring
safety and defining the transient phenomena such as
increase of the rotational speed (runaway) of the
units, increase of the pressure (head) in the hydraulic
system (water hammer) and water level oscillation in
the surge tank. Transient phenomena in HPP occurs
during unit shutdown or startup, switching from one
operation regime of HPP to another, load rejection,
emergency shutdown, out of phase of
synchronization etc.
The accurate definition of the transient
phenomena of the HPP and its units, taking into
account various aspects of operation is an essential
requirement for the design, performances and control
of HPP. The numerical results of transient
phenomena analyses are relied upon for very costly
engineering decisions. Because of this, it is important
that the researcher understands the effect unknown
modeling parameters on the result of transient
analysis. Usually, different researchers may choose
alternate values for an unknown modeling parameter
and this can have significant effects on the results.
II. CASE STUDY
The case study of the HPP operation presented
here investigates two units with vertical Francis
turbines each with rated capacity of 40 MW and flow
rate of 50 m3/s. A complete model of the
hydropower plant with all corresponding elements is
shown in Figure 1.
The HPP consists of the following hydraulic
components: upstream reservoir (accumulation),
gallery, surge tank, penstock(pipeline), valve, Francis
turbine(s) and downstream reservoir (tailrace).
Technical characteristics of the hydropower plant are
given in Table 1.
The sensitivity of transient phenomena for
emergency shutdown scenario of two
unit(simultaneously) was investigated by variation in
the following modeling parameters:
 pipeline friction factor,
 wave speed,
 surge tank throttling coefficient,
 turbine guide vanes closing law and
 generator inertia.
These parameters used in sensitivity transient
analyses are often the subject of estimates or
assumption based on the available designs, and thus
are likely to contribute to a high portion of the error
in the analysis. . Parameters such as pipe length and
diameter, acceleration due to gravity and the density
of water would also likely, have an impact on the
transient analysis if they were to vary, but these are
well known and nearly constant parameters. The limit
of the sensitivity analysis was based on the maximum
and minimum likely value for each modeling
parameter. This parameters for different transient
simulation scenarios (B,C,D,E,F) are presented in
Table 2. The software package WHAMO is used for
all numerical computations.
RESEARCH ARTICLE OPEN ACCESS
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 266 | P a g e
Fig.1 Layout of the hydropower plant with Francis turbines
Table 1 Characteristics of HPP (rated values)
Upstream
reservoir Gallery Surge tank Penstock Turbine Generator
Hmax=109 [m] L=98 [m]
D=5.0 [m]
λ=0.02
а=1050 [m/s]
AS =19.60 [m2
]
Аt =8.44 [m2
]
Hmax=40 [m]
L =220 [m]
D=5.0/3.12 [m]
λ=0.02
а=1020 [m/s]
H0=92 [m]
n0=300 [min-1
]
Q0=50 [m3
/s]
P0=40 [MW]
JT = 30 [tm2
]
JG=1500 tm2
Table 2 Values of modeling parameters for different scenarios
III. VALIDATION OF THE NUMERICAL
MODEL
The The numerical modeling and results from
simulation of the transient phenomena for
emergency shutdown(simultaneously) of two Francis
turbine for scenario A (base case) is shown in Fig.2
an Fig.3-left.
The guide vanes closing law (12.5 seconds
linearly) after emergency shutdown is shown in
Fig.3-right. The time step of iterations (Δt=0.001 [s])
is determined according Lewy-Courant criteria [1].
The reliability of the numerical computation is
confirmed by verification using experimental data
[2] obtained with field measurements. The
comparison of the results is presented in Table 3. By
comparing the results can be concluded that the
maximum amplitudes of the pressure (water
hammer) and maximum increase of the turbine
rotational speed (runaway) in a very good agreement
(the error is 1%).
Table 3 The comparison of the results
Scenario
B C D E F
a(gallery)
[m/s]
a(penstock)
[m/s]
J
[tm2
]
gv
[s]
Ast
[m2
]
λ(gallery)
[-]
λ(penstock)
[-]
1 (min) 1245 1323 1200 6 2.6 0.005 0.0045
2 (max) 1481 1481 1800 8 14.2 0.025 0.02
3 / / / 14 / / /
Base case
(scenario A)
1317 1410 1500 12.5 8.44 0.015 0.012
Measurements Simulation Error
nmax [min-1
] Hmax [m] nmax [min-1
] Hmax [m] nmax [%] Hmax [%]
Base case A 427.5 145.1 430.9 146.7 0.79 1.1
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 267 | P a g e
Fig. 2 Results of the simulation for scenario A (base case)
Fig. 3 Results of the simulation for scenario A (base case)
IV. VALIDATION OF THE NUMERICAL
MODEL
After validation of the numerical model, the
following transient computation scenarios for
emergency shutdown of hydroelectric power plant
are analyzed (Table 2):
 Scenario B: variation o the wave speed
 Scenario C: variation of the generator inertia
 Scenario D: variation of the turbine guide vanes
closing law
 Scenario E: variation of the surge tank throttling
coefficient
 Scenario F: variation of the pipeline friction
factor
The wave speed for base case A is calculated
according to following equation:
1
2
1
/
c
D
E
K
K
a






















In this equation K represents bulk modulus of
elasticity of the liquid in the pipe, ρ is density of the
fluid, E is young’s modulus of material that pipes are
made of, δ is pipe equivalent wall thickness, c1 is a
coefficient that takes in consideration the type of the
pipeline stiffening i.e., [3]:
Case 1: For pipeline that is stiffened on one end only,
c1 = 1-μ/2
Case 2: For pipeline that is stiffened on two ends; c1
= 1-μ2
Case 3: For pipeline that is not stiffened c1 = 1
In c1 expressions, µ represents Poison’s ratio that
depends on material that pipes are made of.
The maximum wave speed is calculated by
equation (1), which is the wave speed in a perfectly
rigid pipeline (bulk modulus of water assumed 2.15
GPa). The lower limit for the wave speed is based on
a 10% reduction of the bulk fluid modulus (due to
reduced water temperature and/or air entrainment),
and a 50% reduction in the gallery rigidity
(representing an underestimation of the elasticity of
the surrounding rock).
The upper and lower limits for generator inertia
are based on a 20% increase and reduction in the
inertia, corresponding to incorrect estimation of the
generator inertia in the early stages of a project.
The upper and lower limits for generator inertia
are based on a 20% increase and reduction in the
inertia, corresponding to incorrect estimation of the
generator inertia in the early stages of a project.
The turbine guide vanes closing law is defining
for different case of linearly closing time (fast and
slowly). The inlet head loss in the surge tank are
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 268 | P a g e
based on throttling of the surge tank through
variation of cross section area in the junction or
throttling coefficient kt. The variation of the friction
factor are based on the range of roughness values for
concrete (gallery) and steel (penstock).
The inlet head loss in the surge tank are based on
throttling of the surge tank through variation ofcross
section area in the junction or throttling coefficient kt.
The variation of the friction factor are based on
the range of roughness values for concrete (gallery)
and steel (penstock).
V. RESULTS FROM SENSITIVITY
ANALYSIS
Sensitivity was analysis by investigating the
output turbine conditions (transient phenomena) for
each case study (water hammer (turbine inlet head),
unit rotational speed and oscillation (head) in the
surge tank) in comparison to results obtained for the
base case A. For the case study with scenario
A,B,C,E,F the turbine guide vanes closing law is 12.5
seconds linearly (Fig.3-right) after emergency
shutdown (simultaneously) of the turbine, while
scenario D (Table.2) have a different time(linearly)
of closing law.
5.1 Variation of the Wave Speed (scenario B)
The sensitivity of transient phenomena with
variation of the wave speed is shown in Fig.4 and
Fig.5.
The turbine inlet head(water hammer) are shown
in Fig.4, while Fig.5 shows the turbine rotational
speed. The water level oscillation in the surge tank is
shown in Fig.6.
Fig. 4 Results for turbine inlet head (scenario B)
Fig. 5 Results for rotational speed (scenario B)
5.2 Variation of the Generator Inertia (Scenario
C)
The sensitivity of transient phenomena with
variation of the generator inertia is shown in Fig.7,
Fig 8 and Fig.9. The turbine inlet head(water
hammer) are shown in Fig.7, while Fig.8 shows the
turbine rotational speed. The water level oscillation
in the surge tank is shown in Fig.9.
Fig. 6 Results for water level oscillation in the surge
tank (scenario B)
Fig. 7 Results for turbine inlet head (scenario C)
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 269 | P a g e
Fig. 8 Results for rotational speed (scenario C)
Fig. 9 Results for water level oscillation in the surge
tank (scenario C)
5.3 Variation of the Turbine Guide Vanes Closing
Law (Scenario D)
The sensitivity of transient phenomena with
variation of the turbine guide vanes closing law is
shown in Fig.10 to Fig. 13. The turbine inlet head
(water hammer) are shown in Fig.10, while Fig.11
shows the turbine rotational speed. The water level
oscillation in the surge tank is shown in Fig.12 and
Fig.13 shows the turbine guide vanes closing law (gv
[%]).
Fig. 10 Results for turbine inlet head (scenario D)
Fig. 11. Results for rotational speed (scenario D)
Fig. 12 Results for water level oscillation in the surge
tank (scenario D)
Fig. 13 Turbine guide vanes closing law
5.4 Variation of the Surge Tank Throttling
Coefficient (Scenario E)
The sensitivity of transient phenomena with
variation of the surge tank throttling coefficient is
shown in Fig.14, Fig. 15 and Fig.11. The turbine inlet
head are shown in Fig.14, while Fig.15 shows the
turbine rotational speed. The water level oscillation
in the surge tank is shown in Fig.16.
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 270 | P a g e
Fig. 14. Results for turbine inlet head (scenario E)
Fig. 15 Results for rotational speed (scenario E)
Fig. 16 Results for water level oscillation in the surge
tank (scenario E)
5.5 Variation of the Pipeline Friction Factor
(Scenario F)
The sensitivity of transient phenomena with
variation of the pipeline friction factor is shown in
Fig.17, Fig. 18 and Fig.19. The turbine inlet
head(water hammer) are shown in Fig.17, while
Fig.18 shows the turbine rotational speed. The water
level oscillation in the surge tank is shown in Fig.19.
Fig. 17. Results for turbine inlet head (scenario F)
Fig. 18 Results for rotational speed (scenario F)
Fig. 19 Results for water level oscillation in the surge
tank (scenario F)
5.6 Summary, Comparison and Explanation of the
Results
The variation of the turbine rotational speed for
each modeling parameters (different scenarios) is
shown in Fig. 20, while Fig. 21 shows the variation
of the maximum turbine inlet head.
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 271 | P a g e
Fig. 20 Results for rotational speed
Fig. 21 Results for maximum turbine inlet head
The variation of the minimum turbine inlet head
turbine for each modeling parameters (different
scenarios) is shown in Fig. 22, while Fig. 23 shows
the variation of the maximum water level oscillation
in the surge tank.
Fig. 22 Results for minimum turbine inlet head
Fig. 23 Results for maximum water level oscillation
in the surge tank
The variation of the minimum water level
oscillation in the surge tank for each modeling
parameters (different scenarios) is shown in Fig. 24.
Fig. 24 Results for minimum water level oscillation
in the surge tank
The sensitivity of output turbine conditions for
variation of each modeling parameters is summarized
in Table 4.
By comparing the simulation results can be
concluded that the variation of the wave speed there
is not effect to the amplitudes (max/min) of the
turbine inlet head (Table 4) and time of occurrence of
the head peaks. By examining Fig.4 can be concluded
that there is small discrepancies in the time evolution
of the turbine inlet head after guide vanes closure.
These are probably due to the water hammer
reflections and differ in frequency due to the
difference in wave speed.
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 272 | P a g e
Table 4. Summary of the results
Varying the generator inertia had a significant
variation in the turbine rotational speed (Fig.8) and
turbine inlet head (Fig.7), although there is negligible
effect on the water level oscillation in the surge tank.
By comparing the results it is apparent that for
increased generator inertia, the head (water hammer)
rise while turbine speed (runaway) reduce, else the
head reduce while the turbine speed rise. With
variation of the generator inertia (±20%) that was
examined, the head rise and turbine speed rise both
vary by cca.10%. Before a turbine manufacturer has
been contracted, the generator inertia often has to be
assumed. Because of this, it is important to
investigate the sensitivity of the analysis results to
variations in inertia.
For the different guide vanes closing time
investigated, there was a significant variation in the
all output conditions for the turbine. This modeling
parameter is main criteria which directly affect to the
so-called guaranteed control values of the HPP,
allowed increase of the head (water hammer) and
allowed increase of the rotational speed (runaway).
Therefore, it is necessary to define the guide vanes
minimum closing time, so that the maximum value of
the pressure(head) at the turbine and the maximum
value of the turbine’s rotational speed be within
permissible limits i.e. not exceed the guaranteed
control values. To evaluate the influence of the guide
vanes closing time on the guaranteed control values,
it’s necessary to perform series of computations for
different values of the guide vanes closing time. For
example (see Table 4), if the guide vanes closing
time is 6 [s] (linearly closing-Scenario D1) then the
increase of the head (water hammer) at the turbine is
cca.63% (Hmax=159.53 [m]) higher compared to the
hydrostatic head H0 = 98 [m], while the increase of
the turbine rotational speed (runaway) is cca.38%
higher (nmax=413.20 [min-1
]) compared to the rated
value of the rotational speed (n0=300 [min-1
]). These
values for the increase the head and rotational speed
must be (limited) smaller than the guarantee control
values (Hmax<Hguar., nmax<nguar.). Thus, shortest
possible guide vanes closing time can be determined.
With variation the throttling coefficient (or cross
section area in the junction) of the surge tank
significant variation in water level oscillation is
obtained. The maximum and minimum water level
oscillation varying by over 10%. By examining
Fig.16 and Table 4 can be concluded that the higher
throttling coefficient reduce the variation of water
level oscillation in the surge tank. Varying the
throttling coefficient had a negligible effect on the
turbine rotational speed, while turbine inlet
head(max/min) varied by approximately 2%.
In this case study the variations in pipe friction
factor resulted in notable changes in all turbine
outputs. Of additional interest is the possible
variation in turbine head from the initially(steady
state) estimated “base case A”. According Fig.17,
Fig. 18 and Fig . 19 can be concluded that the lower
pipe friction is likely to lead to higher pressure peaks
at the turbine inlet, turbine speed increase, and
variation of water level in the surge tank.
VI. CONCLUSION
In this paper, sensitivity of transient phenomena
analysis of the HPP with variation in modeling
parameters such as pipeline friction factor, wave
Scenario No.
Rotational
speed
nmax
Maximum
head
Hmax
Minimum
head
Hmin
Maximum
oscillation
Zmax
Minimum
oscillation
Zmin
(min-1
) (m) (m) (m) (m)
1 A (Base case) 430.90 146.70 89.86 108.20 90.71
2 B1 431.00 147.10 90.19 108.20 90.71
3 B2 430.60 146.43 89.64 108.20 90.74
4 C1 444.80 144.10 90.00 108.20 90.71
5 C2 418.70 149.91 89.49 108.17 90.74
6 D1 413.20 159.53 77.18 109.18 89.98
7 D2 423.10 149.75 82.48 108.81 90.25
8 D3 438.10 142.55 90.95 107.11 91.59
9 E1 430.70 146.46 88.48 108.69 89.82
10 E2 433.50 150.20 92.17 99.91 97.66
11 F1 429.80 146.33 89.98 108.11 90.89
12 F2 432.10 147.13 89.61 108.33 90.50
Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com
ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273
www.ijera.com 273 | P a g e
speed, surge tank throttling coefficient, turbine guide
vanes closing and generator inertia is presented.
Numerical modeling and computation of transient
phenomena of the HPP during emergency shutdown
for base case was first investigated. The reliability of
the numerical simulation is confirmed by comparison
of the computation results with experimental data
obtained. Each modeling input parameters have been
based on the maximum and minimum values. In the
base case each modeling parameters have a best
estimate values. By transient phenomena analysis can
be concluded that some modeling parameters are
likely to have a significant impact on the computation
results of a transient analysis than others. Future
research may be seen in investigated of the influence
of others parameters of the analysis. These
parameters can be following: time step iteration of
the computation, unit characteristics(hill chart), the
effect of discrete loss (junctions, bends) etc.
REFERENCES
[1] S. Mario “Pipeline hydro-dynamics”
(Croatian), Faculty of Mechanical
Engineering and Naval Architecture,
Zagreb, 2005.
[2] V. Iliev “Analysis of the influence of the
unsteady phenomena in the intake
structures, penstocks and units of the hydro
power plants during transient regimes”,
Master Thesis, Faculty of Mechanical
Engineering, Skopje-Macedonia, 2011.
[3] A. B. Almeida, E. Koelle (1992): Fluid
Transients in Pipe Networks, C. M. P.,
Elsevier.
[4] M. Hanif Chaudry “Applied Hydraulic
Transients”, British Columbia Hydro and
Power Authority Vancouver, Canada, 1979.
[5] E. B. Wylie, Victor L. Streeter “Fluid
Transients”, University of Michigan, 2001.
[6] Charles Jaeger “Fluid Transients in Hydro-
Electric Engineering Practise”, University
of Glasgow, 1977.
[7] Christophe Nicolet “Hydroacoustic
modelling and numerical simulation of
unsteady operation of hydroelectric
systems” A La Faculte Sciences Et
Techniques De Lingenieur, Labaratoire de
machines hydrauliques, Thesis No 3751,
Lausanne 2007.

More Related Content

What's hot

Simulation requirements and relevant load conditions in the design of floatin...
Simulation requirements and relevant load conditions in the design of floatin...Simulation requirements and relevant load conditions in the design of floatin...
Simulation requirements and relevant load conditions in the design of floatin...Ricardo Faerron Guzmán
 
IRJET- A Comparative Study of Design of DAM
IRJET- A Comparative Study of Design of DAMIRJET- A Comparative Study of Design of DAM
IRJET- A Comparative Study of Design of DAMIRJET Journal
 
Studies on impact of inlet viscosity ratio, decay rate & length scales in a c...
Studies on impact of inlet viscosity ratio, decay rate & length scales in a c...Studies on impact of inlet viscosity ratio, decay rate & length scales in a c...
Studies on impact of inlet viscosity ratio, decay rate & length scales in a c...QuEST Global
 
NUMERICAL STUDIES ON THE LIQUID REQUIREMENTS FOR COMPLETE TRANSIENT CHILLDOWN...
NUMERICAL STUDIES ON THE LIQUID REQUIREMENTS FOR COMPLETE TRANSIENT CHILLDOWN...NUMERICAL STUDIES ON THE LIQUID REQUIREMENTS FOR COMPLETE TRANSIENT CHILLDOWN...
NUMERICAL STUDIES ON THE LIQUID REQUIREMENTS FOR COMPLETE TRANSIENT CHILLDOWN...IAEME Publication
 
Final Group Design Presentation 03 06 10
Final Group Design Presentation 03 06 10Final Group Design Presentation 03 06 10
Final Group Design Presentation 03 06 10m_phull
 
IRJET- Design the Shell and Tube Heat Exchanger with the Help of Programming ...
IRJET- Design the Shell and Tube Heat Exchanger with the Help of Programming ...IRJET- Design the Shell and Tube Heat Exchanger with the Help of Programming ...
IRJET- Design the Shell and Tube Heat Exchanger with the Help of Programming ...IRJET Journal
 
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeNumerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeeSAT Journals
 
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeNumerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeeSAT Publishing House
 
Cfd and conjugate heat transfer analysis of heat sinks with different fin geo...
Cfd and conjugate heat transfer analysis of heat sinks with different fin geo...Cfd and conjugate heat transfer analysis of heat sinks with different fin geo...
Cfd and conjugate heat transfer analysis of heat sinks with different fin geo...eSAT Journals
 
REVIEW OF FLOW DISTRIBUTION NETWORK ANALYSIS FOR DISCHARGE SIDE OF CENTRIFUGA...
REVIEW OF FLOW DISTRIBUTION NETWORK ANALYSIS FOR DISCHARGE SIDE OF CENTRIFUGA...REVIEW OF FLOW DISTRIBUTION NETWORK ANALYSIS FOR DISCHARGE SIDE OF CENTRIFUGA...
REVIEW OF FLOW DISTRIBUTION NETWORK ANALYSIS FOR DISCHARGE SIDE OF CENTRIFUGA...ijiert bestjournal
 
Magneto-Convection of Immiscible Fluids in a Vertical Channel Using Robin Bou...
Magneto-Convection of Immiscible Fluids in a Vertical Channel Using Robin Bou...Magneto-Convection of Immiscible Fluids in a Vertical Channel Using Robin Bou...
Magneto-Convection of Immiscible Fluids in a Vertical Channel Using Robin Bou...IJERA Editor
 
Numerical study of heat transfer in pulsating turbulent air flow
Numerical study of heat transfer in pulsating turbulent air flowNumerical study of heat transfer in pulsating turbulent air flow
Numerical study of heat transfer in pulsating turbulent air flowMohamed Fadl
 
CFD Analysis of Heat Transfer in Helical Coil
CFD Analysis of Heat Transfer in Helical CoilCFD Analysis of Heat Transfer in Helical Coil
CFD Analysis of Heat Transfer in Helical CoilIRJET Journal
 
Introduction to Computational Fluid Dynamics
Introduction to Computational Fluid DynamicsIntroduction to Computational Fluid Dynamics
Introduction to Computational Fluid DynamicsiMentor Education
 
On assessing the accuracy of offshore wind turbine reliability based design
On assessing the accuracy of offshore wind turbine reliability based designOn assessing the accuracy of offshore wind turbine reliability based design
On assessing the accuracy of offshore wind turbine reliability based designabelkrusnik02
 
IRJET-To Investigate the effect of Spinner Geometry on COP of Vortex Tube Ref...
IRJET-To Investigate the effect of Spinner Geometry on COP of Vortex Tube Ref...IRJET-To Investigate the effect of Spinner Geometry on COP of Vortex Tube Ref...
IRJET-To Investigate the effect of Spinner Geometry on COP of Vortex Tube Ref...IRJET Journal
 
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin InclinationsCFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin InclinationsIJERA Editor
 
Aircraft propulsion matching and off design
Aircraft propulsion   matching and off designAircraft propulsion   matching and off design
Aircraft propulsion matching and off designAnurak Atthasit
 

What's hot (20)

Simulation requirements and relevant load conditions in the design of floatin...
Simulation requirements and relevant load conditions in the design of floatin...Simulation requirements and relevant load conditions in the design of floatin...
Simulation requirements and relevant load conditions in the design of floatin...
 
IRJET- A Comparative Study of Design of DAM
IRJET- A Comparative Study of Design of DAMIRJET- A Comparative Study of Design of DAM
IRJET- A Comparative Study of Design of DAM
 
Studies on impact of inlet viscosity ratio, decay rate & length scales in a c...
Studies on impact of inlet viscosity ratio, decay rate & length scales in a c...Studies on impact of inlet viscosity ratio, decay rate & length scales in a c...
Studies on impact of inlet viscosity ratio, decay rate & length scales in a c...
 
NUMERICAL STUDIES ON THE LIQUID REQUIREMENTS FOR COMPLETE TRANSIENT CHILLDOWN...
NUMERICAL STUDIES ON THE LIQUID REQUIREMENTS FOR COMPLETE TRANSIENT CHILLDOWN...NUMERICAL STUDIES ON THE LIQUID REQUIREMENTS FOR COMPLETE TRANSIENT CHILLDOWN...
NUMERICAL STUDIES ON THE LIQUID REQUIREMENTS FOR COMPLETE TRANSIENT CHILLDOWN...
 
Final Group Design Presentation 03 06 10
Final Group Design Presentation 03 06 10Final Group Design Presentation 03 06 10
Final Group Design Presentation 03 06 10
 
Ijmet 10 02_021
Ijmet 10 02_021Ijmet 10 02_021
Ijmet 10 02_021
 
IRJET- Design the Shell and Tube Heat Exchanger with the Help of Programming ...
IRJET- Design the Shell and Tube Heat Exchanger with the Help of Programming ...IRJET- Design the Shell and Tube Heat Exchanger with the Help of Programming ...
IRJET- Design the Shell and Tube Heat Exchanger with the Help of Programming ...
 
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeNumerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
 
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeNumerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
 
Cfd and conjugate heat transfer analysis of heat sinks with different fin geo...
Cfd and conjugate heat transfer analysis of heat sinks with different fin geo...Cfd and conjugate heat transfer analysis of heat sinks with different fin geo...
Cfd and conjugate heat transfer analysis of heat sinks with different fin geo...
 
REVIEW OF FLOW DISTRIBUTION NETWORK ANALYSIS FOR DISCHARGE SIDE OF CENTRIFUGA...
REVIEW OF FLOW DISTRIBUTION NETWORK ANALYSIS FOR DISCHARGE SIDE OF CENTRIFUGA...REVIEW OF FLOW DISTRIBUTION NETWORK ANALYSIS FOR DISCHARGE SIDE OF CENTRIFUGA...
REVIEW OF FLOW DISTRIBUTION NETWORK ANALYSIS FOR DISCHARGE SIDE OF CENTRIFUGA...
 
Magneto-Convection of Immiscible Fluids in a Vertical Channel Using Robin Bou...
Magneto-Convection of Immiscible Fluids in a Vertical Channel Using Robin Bou...Magneto-Convection of Immiscible Fluids in a Vertical Channel Using Robin Bou...
Magneto-Convection of Immiscible Fluids in a Vertical Channel Using Robin Bou...
 
Numerical study of heat transfer in pulsating turbulent air flow
Numerical study of heat transfer in pulsating turbulent air flowNumerical study of heat transfer in pulsating turbulent air flow
Numerical study of heat transfer in pulsating turbulent air flow
 
CFD Analysis of Heat Transfer in Helical Coil
CFD Analysis of Heat Transfer in Helical CoilCFD Analysis of Heat Transfer in Helical Coil
CFD Analysis of Heat Transfer in Helical Coil
 
Introduction to Computational Fluid Dynamics
Introduction to Computational Fluid DynamicsIntroduction to Computational Fluid Dynamics
Introduction to Computational Fluid Dynamics
 
On assessing the accuracy of offshore wind turbine reliability based design
On assessing the accuracy of offshore wind turbine reliability based designOn assessing the accuracy of offshore wind turbine reliability based design
On assessing the accuracy of offshore wind turbine reliability based design
 
IRJET-To Investigate the effect of Spinner Geometry on COP of Vortex Tube Ref...
IRJET-To Investigate the effect of Spinner Geometry on COP of Vortex Tube Ref...IRJET-To Investigate the effect of Spinner Geometry on COP of Vortex Tube Ref...
IRJET-To Investigate the effect of Spinner Geometry on COP of Vortex Tube Ref...
 
Hr2413591363
Hr2413591363Hr2413591363
Hr2413591363
 
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin InclinationsCFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
 
Aircraft propulsion matching and off design
Aircraft propulsion   matching and off designAircraft propulsion   matching and off design
Aircraft propulsion matching and off design
 

Viewers also liked

Fe Analysis of Effect of Tyre Overload and Inflation Pressure on Rolling Loss...
Fe Analysis of Effect of Tyre Overload and Inflation Pressure on Rolling Loss...Fe Analysis of Effect of Tyre Overload and Inflation Pressure on Rolling Loss...
Fe Analysis of Effect of Tyre Overload and Inflation Pressure on Rolling Loss...IJERA Editor
 
Continuous rigid PC frame box girder cantilever pouring construction reasonab...
Continuous rigid PC frame box girder cantilever pouring construction reasonab...Continuous rigid PC frame box girder cantilever pouring construction reasonab...
Continuous rigid PC frame box girder cantilever pouring construction reasonab...IJERA Editor
 
A Case Study of Employing A Single Server Nonpreemptive Priority Queuing Mode...
A Case Study of Employing A Single Server Nonpreemptive Priority Queuing Mode...A Case Study of Employing A Single Server Nonpreemptive Priority Queuing Mode...
A Case Study of Employing A Single Server Nonpreemptive Priority Queuing Mode...IJERA Editor
 
Rain Water Harvesting and Impact of Microbial Pollutants on Ground Water Rese...
Rain Water Harvesting and Impact of Microbial Pollutants on Ground Water Rese...Rain Water Harvesting and Impact of Microbial Pollutants on Ground Water Rese...
Rain Water Harvesting and Impact of Microbial Pollutants on Ground Water Rese...IJERA Editor
 
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...IJERA Editor
 
Analysis Of Comparative Strength Model Connection Bolts And Weld To The Plate...
Analysis Of Comparative Strength Model Connection Bolts And Weld To The Plate...Analysis Of Comparative Strength Model Connection Bolts And Weld To The Plate...
Analysis Of Comparative Strength Model Connection Bolts And Weld To The Plate...IJERA Editor
 
A review of Wireless Information and Power Transfer in Multiuser OFDM Systems
A review of Wireless Information and Power Transfer in Multiuser OFDM SystemsA review of Wireless Information and Power Transfer in Multiuser OFDM Systems
A review of Wireless Information and Power Transfer in Multiuser OFDM SystemsIJERA Editor
 
A Systematic Approach to Improve BOC Power Spectrum for GNSS
A Systematic Approach to Improve BOC Power Spectrum for GNSSA Systematic Approach to Improve BOC Power Spectrum for GNSS
A Systematic Approach to Improve BOC Power Spectrum for GNSSIJERA Editor
 
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...IJERA Editor
 
The Level of Base Oil Recovery from Niger Delta Drill Cuttings Using Thermal ...
The Level of Base Oil Recovery from Niger Delta Drill Cuttings Using Thermal ...The Level of Base Oil Recovery from Niger Delta Drill Cuttings Using Thermal ...
The Level of Base Oil Recovery from Niger Delta Drill Cuttings Using Thermal ...IJERA Editor
 
A Low Phase Noise CMOS Quadrature Voltage Control Oscillator Using Clock Gate...
A Low Phase Noise CMOS Quadrature Voltage Control Oscillator Using Clock Gate...A Low Phase Noise CMOS Quadrature Voltage Control Oscillator Using Clock Gate...
A Low Phase Noise CMOS Quadrature Voltage Control Oscillator Using Clock Gate...IJERA Editor
 
Replacement of Natural Fine Aggregate With Air Cooled Blast Furnace Slag An I...
Replacement of Natural Fine Aggregate With Air Cooled Blast Furnace Slag An I...Replacement of Natural Fine Aggregate With Air Cooled Blast Furnace Slag An I...
Replacement of Natural Fine Aggregate With Air Cooled Blast Furnace Slag An I...IJERA Editor
 
Denoising of ECG -- A discrete time approach using DWT.
Denoising of ECG -- A discrete time approach using DWT.Denoising of ECG -- A discrete time approach using DWT.
Denoising of ECG -- A discrete time approach using DWT.IJERA Editor
 
Analyzing Specialized Views of Transportation Under Mean Safety By Using Fuzz...
Analyzing Specialized Views of Transportation Under Mean Safety By Using Fuzz...Analyzing Specialized Views of Transportation Under Mean Safety By Using Fuzz...
Analyzing Specialized Views of Transportation Under Mean Safety By Using Fuzz...IJERA Editor
 
Juegodelavida (1)
Juegodelavida (1)Juegodelavida (1)
Juegodelavida (1)Rosy Espino
 
obama if an indian political counterpart
obama if an indian political counterpartobama if an indian political counterpart
obama if an indian political counterpartGopalakrishnan Rajesh
 
Dokumen Investigasi Kasus Munir
Dokumen Investigasi Kasus MunirDokumen Investigasi Kasus Munir
Dokumen Investigasi Kasus MunirIndoleaks
 

Viewers also liked (20)

Fe Analysis of Effect of Tyre Overload and Inflation Pressure on Rolling Loss...
Fe Analysis of Effect of Tyre Overload and Inflation Pressure on Rolling Loss...Fe Analysis of Effect of Tyre Overload and Inflation Pressure on Rolling Loss...
Fe Analysis of Effect of Tyre Overload and Inflation Pressure on Rolling Loss...
 
Continuous rigid PC frame box girder cantilever pouring construction reasonab...
Continuous rigid PC frame box girder cantilever pouring construction reasonab...Continuous rigid PC frame box girder cantilever pouring construction reasonab...
Continuous rigid PC frame box girder cantilever pouring construction reasonab...
 
A Case Study of Employing A Single Server Nonpreemptive Priority Queuing Mode...
A Case Study of Employing A Single Server Nonpreemptive Priority Queuing Mode...A Case Study of Employing A Single Server Nonpreemptive Priority Queuing Mode...
A Case Study of Employing A Single Server Nonpreemptive Priority Queuing Mode...
 
Rain Water Harvesting and Impact of Microbial Pollutants on Ground Water Rese...
Rain Water Harvesting and Impact of Microbial Pollutants on Ground Water Rese...Rain Water Harvesting and Impact of Microbial Pollutants on Ground Water Rese...
Rain Water Harvesting and Impact of Microbial Pollutants on Ground Water Rese...
 
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...
 
Analysis Of Comparative Strength Model Connection Bolts And Weld To The Plate...
Analysis Of Comparative Strength Model Connection Bolts And Weld To The Plate...Analysis Of Comparative Strength Model Connection Bolts And Weld To The Plate...
Analysis Of Comparative Strength Model Connection Bolts And Weld To The Plate...
 
A review of Wireless Information and Power Transfer in Multiuser OFDM Systems
A review of Wireless Information and Power Transfer in Multiuser OFDM SystemsA review of Wireless Information and Power Transfer in Multiuser OFDM Systems
A review of Wireless Information and Power Transfer in Multiuser OFDM Systems
 
A Systematic Approach to Improve BOC Power Spectrum for GNSS
A Systematic Approach to Improve BOC Power Spectrum for GNSSA Systematic Approach to Improve BOC Power Spectrum for GNSS
A Systematic Approach to Improve BOC Power Spectrum for GNSS
 
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
 
The Level of Base Oil Recovery from Niger Delta Drill Cuttings Using Thermal ...
The Level of Base Oil Recovery from Niger Delta Drill Cuttings Using Thermal ...The Level of Base Oil Recovery from Niger Delta Drill Cuttings Using Thermal ...
The Level of Base Oil Recovery from Niger Delta Drill Cuttings Using Thermal ...
 
A Low Phase Noise CMOS Quadrature Voltage Control Oscillator Using Clock Gate...
A Low Phase Noise CMOS Quadrature Voltage Control Oscillator Using Clock Gate...A Low Phase Noise CMOS Quadrature Voltage Control Oscillator Using Clock Gate...
A Low Phase Noise CMOS Quadrature Voltage Control Oscillator Using Clock Gate...
 
Replacement of Natural Fine Aggregate With Air Cooled Blast Furnace Slag An I...
Replacement of Natural Fine Aggregate With Air Cooled Blast Furnace Slag An I...Replacement of Natural Fine Aggregate With Air Cooled Blast Furnace Slag An I...
Replacement of Natural Fine Aggregate With Air Cooled Blast Furnace Slag An I...
 
Denoising of ECG -- A discrete time approach using DWT.
Denoising of ECG -- A discrete time approach using DWT.Denoising of ECG -- A discrete time approach using DWT.
Denoising of ECG -- A discrete time approach using DWT.
 
Analyzing Specialized Views of Transportation Under Mean Safety By Using Fuzz...
Analyzing Specialized Views of Transportation Under Mean Safety By Using Fuzz...Analyzing Specialized Views of Transportation Under Mean Safety By Using Fuzz...
Analyzing Specialized Views of Transportation Under Mean Safety By Using Fuzz...
 
Maria Fàbregues
Maria FàbreguesMaria Fàbregues
Maria Fàbregues
 
Juegodelavida (1)
Juegodelavida (1)Juegodelavida (1)
Juegodelavida (1)
 
El paraguas de house of diehl
El paraguas de house of diehlEl paraguas de house of diehl
El paraguas de house of diehl
 
obama if an indian political counterpart
obama if an indian political counterpartobama if an indian political counterpart
obama if an indian political counterpart
 
Dokumen Investigasi Kasus Munir
Dokumen Investigasi Kasus MunirDokumen Investigasi Kasus Munir
Dokumen Investigasi Kasus Munir
 
ppt 22 set
ppt 22 setppt 22 set
ppt 22 set
 

Similar to Sensitivity of Transient Phenomena Analysis of the Francis Turbine Power Plants

IRJET- Study on Comparison Analysis of Circular and Intze Water Tank on Slopi...
IRJET- Study on Comparison Analysis of Circular and Intze Water Tank on Slopi...IRJET- Study on Comparison Analysis of Circular and Intze Water Tank on Slopi...
IRJET- Study on Comparison Analysis of Circular and Intze Water Tank on Slopi...IRJET Journal
 
Optimization of Closure Law of Guide Vanes for an Operational Hydropower Plan...
Optimization of Closure Law of Guide Vanes for an Operational Hydropower Plan...Optimization of Closure Law of Guide Vanes for an Operational Hydropower Plan...
Optimization of Closure Law of Guide Vanes for an Operational Hydropower Plan...Dr. Amarjeet Singh
 
Transient analysis and fatigue life prediction of tubesheet
Transient analysis and fatigue life prediction of tubesheetTransient analysis and fatigue life prediction of tubesheet
Transient analysis and fatigue life prediction of tubesheeteSAT Publishing House
 
A Study of the Root Causes of High Failure Rate of Distribution Transformer -...
A Study of the Root Causes of High Failure Rate of Distribution Transformer -...A Study of the Root Causes of High Failure Rate of Distribution Transformer -...
A Study of the Root Causes of High Failure Rate of Distribution Transformer -...theijes
 
Improved Control Strategy for Low Voltage Ride Through Capability of DFIG wit...
Improved Control Strategy for Low Voltage Ride Through Capability of DFIG wit...Improved Control Strategy for Low Voltage Ride Through Capability of DFIG wit...
Improved Control Strategy for Low Voltage Ride Through Capability of DFIG wit...ecij
 
Employing facts devices upfc for transient stability improvement
Employing facts devices  upfc   for transient stability improvementEmploying facts devices  upfc   for transient stability improvement
Employing facts devices upfc for transient stability improvementIAEME Publication
 
Implementation of Wilcox k − ω model to UCNS3D
Implementation of Wilcox k − ω model to UCNS3DImplementation of Wilcox k − ω model to UCNS3D
Implementation of Wilcox k − ω model to UCNS3DArpit Aggarwal
 
Modeling and Analysis of a 3-Phase 132kv GasInsulated Substation
Modeling and Analysis of a 3-Phase 132kv GasInsulated SubstationModeling and Analysis of a 3-Phase 132kv GasInsulated Substation
Modeling and Analysis of a 3-Phase 132kv GasInsulated SubstationIRJET Journal
 
IRJET- A Modified Stilling Basin with Flow-Guide Pipes to Improve Hydraul...
IRJET-  	  A Modified Stilling Basin with Flow-Guide Pipes to Improve Hydraul...IRJET-  	  A Modified Stilling Basin with Flow-Guide Pipes to Improve Hydraul...
IRJET- A Modified Stilling Basin with Flow-Guide Pipes to Improve Hydraul...IRJET Journal
 
Accurate leakage current models for MOSFET nanoscale devices
Accurate leakage current models for MOSFET nanoscale devices Accurate leakage current models for MOSFET nanoscale devices
Accurate leakage current models for MOSFET nanoscale devices IJECEIAES
 
IRJET- Study of Fluid Induced Vibrations using Simulation Means and their Eff...
IRJET- Study of Fluid Induced Vibrations using Simulation Means and their Eff...IRJET- Study of Fluid Induced Vibrations using Simulation Means and their Eff...
IRJET- Study of Fluid Induced Vibrations using Simulation Means and their Eff...IRJET Journal
 
IRJET - DFIG Control Design for Preventing SSR Mode
IRJET -  	  DFIG Control Design for Preventing SSR ModeIRJET -  	  DFIG Control Design for Preventing SSR Mode
IRJET - DFIG Control Design for Preventing SSR ModeIRJET Journal
 
Analysis of Circular Water Tanks under Different SeismicConditions For Two Di...
Analysis of Circular Water Tanks under Different SeismicConditions For Two Di...Analysis of Circular Water Tanks under Different SeismicConditions For Two Di...
Analysis of Circular Water Tanks under Different SeismicConditions For Two Di...IRJET Journal
 
Fault Analysis of DFIG under Grid Disturbances
Fault Analysis of DFIG under Grid DisturbancesFault Analysis of DFIG under Grid Disturbances
Fault Analysis of DFIG under Grid DisturbancesIJERA Editor
 
CFD analysis of flow through T-Junction of pipe
CFD analysis of flow through  T-Junction of pipeCFD analysis of flow through  T-Junction of pipe
CFD analysis of flow through T-Junction of pipeIRJET Journal
 

Similar to Sensitivity of Transient Phenomena Analysis of the Francis Turbine Power Plants (20)

Ijett v25 p238
Ijett v25 p238Ijett v25 p238
Ijett v25 p238
 
FULLTEXT01.pdf
FULLTEXT01.pdfFULLTEXT01.pdf
FULLTEXT01.pdf
 
40220140505009
4022014050500940220140505009
40220140505009
 
IRJET- Study on Comparison Analysis of Circular and Intze Water Tank on Slopi...
IRJET- Study on Comparison Analysis of Circular and Intze Water Tank on Slopi...IRJET- Study on Comparison Analysis of Circular and Intze Water Tank on Slopi...
IRJET- Study on Comparison Analysis of Circular and Intze Water Tank on Slopi...
 
Dh4201729733
Dh4201729733Dh4201729733
Dh4201729733
 
Optimization of Closure Law of Guide Vanes for an Operational Hydropower Plan...
Optimization of Closure Law of Guide Vanes for an Operational Hydropower Plan...Optimization of Closure Law of Guide Vanes for an Operational Hydropower Plan...
Optimization of Closure Law of Guide Vanes for an Operational Hydropower Plan...
 
Transient analysis and fatigue life prediction of tubesheet
Transient analysis and fatigue life prediction of tubesheetTransient analysis and fatigue life prediction of tubesheet
Transient analysis and fatigue life prediction of tubesheet
 
A Study of the Root Causes of High Failure Rate of Distribution Transformer -...
A Study of the Root Causes of High Failure Rate of Distribution Transformer -...A Study of the Root Causes of High Failure Rate of Distribution Transformer -...
A Study of the Root Causes of High Failure Rate of Distribution Transformer -...
 
Improved Control Strategy for Low Voltage Ride Through Capability of DFIG wit...
Improved Control Strategy for Low Voltage Ride Through Capability of DFIG wit...Improved Control Strategy for Low Voltage Ride Through Capability of DFIG wit...
Improved Control Strategy for Low Voltage Ride Through Capability of DFIG wit...
 
Employing facts devices upfc for transient stability improvement
Employing facts devices  upfc   for transient stability improvementEmploying facts devices  upfc   for transient stability improvement
Employing facts devices upfc for transient stability improvement
 
Implementation of Wilcox k − ω model to UCNS3D
Implementation of Wilcox k − ω model to UCNS3DImplementation of Wilcox k − ω model to UCNS3D
Implementation of Wilcox k − ω model to UCNS3D
 
Modeling and Analysis of a 3-Phase 132kv GasInsulated Substation
Modeling and Analysis of a 3-Phase 132kv GasInsulated SubstationModeling and Analysis of a 3-Phase 132kv GasInsulated Substation
Modeling and Analysis of a 3-Phase 132kv GasInsulated Substation
 
IRJET- A Modified Stilling Basin with Flow-Guide Pipes to Improve Hydraul...
IRJET-  	  A Modified Stilling Basin with Flow-Guide Pipes to Improve Hydraul...IRJET-  	  A Modified Stilling Basin with Flow-Guide Pipes to Improve Hydraul...
IRJET- A Modified Stilling Basin with Flow-Guide Pipes to Improve Hydraul...
 
Accurate leakage current models for MOSFET nanoscale devices
Accurate leakage current models for MOSFET nanoscale devices Accurate leakage current models for MOSFET nanoscale devices
Accurate leakage current models for MOSFET nanoscale devices
 
F044082128
F044082128F044082128
F044082128
 
IRJET- Study of Fluid Induced Vibrations using Simulation Means and their Eff...
IRJET- Study of Fluid Induced Vibrations using Simulation Means and their Eff...IRJET- Study of Fluid Induced Vibrations using Simulation Means and their Eff...
IRJET- Study of Fluid Induced Vibrations using Simulation Means and their Eff...
 
IRJET - DFIG Control Design for Preventing SSR Mode
IRJET -  	  DFIG Control Design for Preventing SSR ModeIRJET -  	  DFIG Control Design for Preventing SSR Mode
IRJET - DFIG Control Design for Preventing SSR Mode
 
Analysis of Circular Water Tanks under Different SeismicConditions For Two Di...
Analysis of Circular Water Tanks under Different SeismicConditions For Two Di...Analysis of Circular Water Tanks under Different SeismicConditions For Two Di...
Analysis of Circular Water Tanks under Different SeismicConditions For Two Di...
 
Fault Analysis of DFIG under Grid Disturbances
Fault Analysis of DFIG under Grid DisturbancesFault Analysis of DFIG under Grid Disturbances
Fault Analysis of DFIG under Grid Disturbances
 
CFD analysis of flow through T-Junction of pipe
CFD analysis of flow through  T-Junction of pipeCFD analysis of flow through  T-Junction of pipe
CFD analysis of flow through T-Junction of pipe
 

Recently uploaded

Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxthe ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxhumanexperienceaaa
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learningmisbanausheenparvam
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidNikhilNagaraju
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSCAESB
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 

Recently uploaded (20)

Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxthe ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learning
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 

Sensitivity of Transient Phenomena Analysis of the Francis Turbine Power Plants

  • 1. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 265 | P a g e Sensitivity of Transient Phenomena Analysis of the Francis Turbine Power Plants Viktor Iliev*, Bojan Ivljanin**, Zoran Markov*, Predrag Popovski *(Ss. Cyril and Methodius” University, Faculty of Mechanical Engineering – Skopje, Macedonia) ** (University of Belgrade, Faculty of Mechanical Engineering - Belgrade, Serbia) ABSTRACT The accurate definition of the transient phenomena of the hydroelectric power plant (HPP) and its units, taking into account various aspects of operation is an essential requirement for design, performances and control of HPPs. Numerical analysis of transient phenomena, such as increase of the rotational speed (runaway) of the units, increase of the pressure (turbine inlet head) in the hydraulic system (water hammer) and water level oscillation in the surge tank is presented. The results of transient phenomena analyses are relied upon for very costly engineering decisions. Because of this, it is important that the researcher understands the effect unknown modeling parameters on the result of transient analysis. Usually, different researchers may choose alternate values for an unknown modeling parameter and this can have significant effects on the results. The main aim in this paper is to investigate of the sensitivity of transient phenomena analysis with variation in modeling parameters such as pipeline friction factor, wave speed, turbine guide vanes closing law, surge tank throttling coefficient and generator inertia. Keywords - Hydropower plant, transient phenomena, water hammer, runaway, sensitivity. I. INTRODUCTION Study the dynamic behavior of a hydropower plant (HPP) is a necessary prerequisite for ensuring safety and defining the transient phenomena such as increase of the rotational speed (runaway) of the units, increase of the pressure (head) in the hydraulic system (water hammer) and water level oscillation in the surge tank. Transient phenomena in HPP occurs during unit shutdown or startup, switching from one operation regime of HPP to another, load rejection, emergency shutdown, out of phase of synchronization etc. The accurate definition of the transient phenomena of the HPP and its units, taking into account various aspects of operation is an essential requirement for the design, performances and control of HPP. The numerical results of transient phenomena analyses are relied upon for very costly engineering decisions. Because of this, it is important that the researcher understands the effect unknown modeling parameters on the result of transient analysis. Usually, different researchers may choose alternate values for an unknown modeling parameter and this can have significant effects on the results. II. CASE STUDY The case study of the HPP operation presented here investigates two units with vertical Francis turbines each with rated capacity of 40 MW and flow rate of 50 m3/s. A complete model of the hydropower plant with all corresponding elements is shown in Figure 1. The HPP consists of the following hydraulic components: upstream reservoir (accumulation), gallery, surge tank, penstock(pipeline), valve, Francis turbine(s) and downstream reservoir (tailrace). Technical characteristics of the hydropower plant are given in Table 1. The sensitivity of transient phenomena for emergency shutdown scenario of two unit(simultaneously) was investigated by variation in the following modeling parameters:  pipeline friction factor,  wave speed,  surge tank throttling coefficient,  turbine guide vanes closing law and  generator inertia. These parameters used in sensitivity transient analyses are often the subject of estimates or assumption based on the available designs, and thus are likely to contribute to a high portion of the error in the analysis. . Parameters such as pipe length and diameter, acceleration due to gravity and the density of water would also likely, have an impact on the transient analysis if they were to vary, but these are well known and nearly constant parameters. The limit of the sensitivity analysis was based on the maximum and minimum likely value for each modeling parameter. This parameters for different transient simulation scenarios (B,C,D,E,F) are presented in Table 2. The software package WHAMO is used for all numerical computations. RESEARCH ARTICLE OPEN ACCESS
  • 2. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 266 | P a g e Fig.1 Layout of the hydropower plant with Francis turbines Table 1 Characteristics of HPP (rated values) Upstream reservoir Gallery Surge tank Penstock Turbine Generator Hmax=109 [m] L=98 [m] D=5.0 [m] λ=0.02 а=1050 [m/s] AS =19.60 [m2 ] Аt =8.44 [m2 ] Hmax=40 [m] L =220 [m] D=5.0/3.12 [m] λ=0.02 а=1020 [m/s] H0=92 [m] n0=300 [min-1 ] Q0=50 [m3 /s] P0=40 [MW] JT = 30 [tm2 ] JG=1500 tm2 Table 2 Values of modeling parameters for different scenarios III. VALIDATION OF THE NUMERICAL MODEL The The numerical modeling and results from simulation of the transient phenomena for emergency shutdown(simultaneously) of two Francis turbine for scenario A (base case) is shown in Fig.2 an Fig.3-left. The guide vanes closing law (12.5 seconds linearly) after emergency shutdown is shown in Fig.3-right. The time step of iterations (Δt=0.001 [s]) is determined according Lewy-Courant criteria [1]. The reliability of the numerical computation is confirmed by verification using experimental data [2] obtained with field measurements. The comparison of the results is presented in Table 3. By comparing the results can be concluded that the maximum amplitudes of the pressure (water hammer) and maximum increase of the turbine rotational speed (runaway) in a very good agreement (the error is 1%). Table 3 The comparison of the results Scenario B C D E F a(gallery) [m/s] a(penstock) [m/s] J [tm2 ] gv [s] Ast [m2 ] λ(gallery) [-] λ(penstock) [-] 1 (min) 1245 1323 1200 6 2.6 0.005 0.0045 2 (max) 1481 1481 1800 8 14.2 0.025 0.02 3 / / / 14 / / / Base case (scenario A) 1317 1410 1500 12.5 8.44 0.015 0.012 Measurements Simulation Error nmax [min-1 ] Hmax [m] nmax [min-1 ] Hmax [m] nmax [%] Hmax [%] Base case A 427.5 145.1 430.9 146.7 0.79 1.1
  • 3. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 267 | P a g e Fig. 2 Results of the simulation for scenario A (base case) Fig. 3 Results of the simulation for scenario A (base case) IV. VALIDATION OF THE NUMERICAL MODEL After validation of the numerical model, the following transient computation scenarios for emergency shutdown of hydroelectric power plant are analyzed (Table 2):  Scenario B: variation o the wave speed  Scenario C: variation of the generator inertia  Scenario D: variation of the turbine guide vanes closing law  Scenario E: variation of the surge tank throttling coefficient  Scenario F: variation of the pipeline friction factor The wave speed for base case A is calculated according to following equation: 1 2 1 / c D E K K a                       In this equation K represents bulk modulus of elasticity of the liquid in the pipe, ρ is density of the fluid, E is young’s modulus of material that pipes are made of, δ is pipe equivalent wall thickness, c1 is a coefficient that takes in consideration the type of the pipeline stiffening i.e., [3]: Case 1: For pipeline that is stiffened on one end only, c1 = 1-μ/2 Case 2: For pipeline that is stiffened on two ends; c1 = 1-μ2 Case 3: For pipeline that is not stiffened c1 = 1 In c1 expressions, µ represents Poison’s ratio that depends on material that pipes are made of. The maximum wave speed is calculated by equation (1), which is the wave speed in a perfectly rigid pipeline (bulk modulus of water assumed 2.15 GPa). The lower limit for the wave speed is based on a 10% reduction of the bulk fluid modulus (due to reduced water temperature and/or air entrainment), and a 50% reduction in the gallery rigidity (representing an underestimation of the elasticity of the surrounding rock). The upper and lower limits for generator inertia are based on a 20% increase and reduction in the inertia, corresponding to incorrect estimation of the generator inertia in the early stages of a project. The upper and lower limits for generator inertia are based on a 20% increase and reduction in the inertia, corresponding to incorrect estimation of the generator inertia in the early stages of a project. The turbine guide vanes closing law is defining for different case of linearly closing time (fast and slowly). The inlet head loss in the surge tank are
  • 4. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 268 | P a g e based on throttling of the surge tank through variation of cross section area in the junction or throttling coefficient kt. The variation of the friction factor are based on the range of roughness values for concrete (gallery) and steel (penstock). The inlet head loss in the surge tank are based on throttling of the surge tank through variation ofcross section area in the junction or throttling coefficient kt. The variation of the friction factor are based on the range of roughness values for concrete (gallery) and steel (penstock). V. RESULTS FROM SENSITIVITY ANALYSIS Sensitivity was analysis by investigating the output turbine conditions (transient phenomena) for each case study (water hammer (turbine inlet head), unit rotational speed and oscillation (head) in the surge tank) in comparison to results obtained for the base case A. For the case study with scenario A,B,C,E,F the turbine guide vanes closing law is 12.5 seconds linearly (Fig.3-right) after emergency shutdown (simultaneously) of the turbine, while scenario D (Table.2) have a different time(linearly) of closing law. 5.1 Variation of the Wave Speed (scenario B) The sensitivity of transient phenomena with variation of the wave speed is shown in Fig.4 and Fig.5. The turbine inlet head(water hammer) are shown in Fig.4, while Fig.5 shows the turbine rotational speed. The water level oscillation in the surge tank is shown in Fig.6. Fig. 4 Results for turbine inlet head (scenario B) Fig. 5 Results for rotational speed (scenario B) 5.2 Variation of the Generator Inertia (Scenario C) The sensitivity of transient phenomena with variation of the generator inertia is shown in Fig.7, Fig 8 and Fig.9. The turbine inlet head(water hammer) are shown in Fig.7, while Fig.8 shows the turbine rotational speed. The water level oscillation in the surge tank is shown in Fig.9. Fig. 6 Results for water level oscillation in the surge tank (scenario B) Fig. 7 Results for turbine inlet head (scenario C)
  • 5. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 269 | P a g e Fig. 8 Results for rotational speed (scenario C) Fig. 9 Results for water level oscillation in the surge tank (scenario C) 5.3 Variation of the Turbine Guide Vanes Closing Law (Scenario D) The sensitivity of transient phenomena with variation of the turbine guide vanes closing law is shown in Fig.10 to Fig. 13. The turbine inlet head (water hammer) are shown in Fig.10, while Fig.11 shows the turbine rotational speed. The water level oscillation in the surge tank is shown in Fig.12 and Fig.13 shows the turbine guide vanes closing law (gv [%]). Fig. 10 Results for turbine inlet head (scenario D) Fig. 11. Results for rotational speed (scenario D) Fig. 12 Results for water level oscillation in the surge tank (scenario D) Fig. 13 Turbine guide vanes closing law 5.4 Variation of the Surge Tank Throttling Coefficient (Scenario E) The sensitivity of transient phenomena with variation of the surge tank throttling coefficient is shown in Fig.14, Fig. 15 and Fig.11. The turbine inlet head are shown in Fig.14, while Fig.15 shows the turbine rotational speed. The water level oscillation in the surge tank is shown in Fig.16.
  • 6. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 270 | P a g e Fig. 14. Results for turbine inlet head (scenario E) Fig. 15 Results for rotational speed (scenario E) Fig. 16 Results for water level oscillation in the surge tank (scenario E) 5.5 Variation of the Pipeline Friction Factor (Scenario F) The sensitivity of transient phenomena with variation of the pipeline friction factor is shown in Fig.17, Fig. 18 and Fig.19. The turbine inlet head(water hammer) are shown in Fig.17, while Fig.18 shows the turbine rotational speed. The water level oscillation in the surge tank is shown in Fig.19. Fig. 17. Results for turbine inlet head (scenario F) Fig. 18 Results for rotational speed (scenario F) Fig. 19 Results for water level oscillation in the surge tank (scenario F) 5.6 Summary, Comparison and Explanation of the Results The variation of the turbine rotational speed for each modeling parameters (different scenarios) is shown in Fig. 20, while Fig. 21 shows the variation of the maximum turbine inlet head.
  • 7. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 271 | P a g e Fig. 20 Results for rotational speed Fig. 21 Results for maximum turbine inlet head The variation of the minimum turbine inlet head turbine for each modeling parameters (different scenarios) is shown in Fig. 22, while Fig. 23 shows the variation of the maximum water level oscillation in the surge tank. Fig. 22 Results for minimum turbine inlet head Fig. 23 Results for maximum water level oscillation in the surge tank The variation of the minimum water level oscillation in the surge tank for each modeling parameters (different scenarios) is shown in Fig. 24. Fig. 24 Results for minimum water level oscillation in the surge tank The sensitivity of output turbine conditions for variation of each modeling parameters is summarized in Table 4. By comparing the simulation results can be concluded that the variation of the wave speed there is not effect to the amplitudes (max/min) of the turbine inlet head (Table 4) and time of occurrence of the head peaks. By examining Fig.4 can be concluded that there is small discrepancies in the time evolution of the turbine inlet head after guide vanes closure. These are probably due to the water hammer reflections and differ in frequency due to the difference in wave speed.
  • 8. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 272 | P a g e Table 4. Summary of the results Varying the generator inertia had a significant variation in the turbine rotational speed (Fig.8) and turbine inlet head (Fig.7), although there is negligible effect on the water level oscillation in the surge tank. By comparing the results it is apparent that for increased generator inertia, the head (water hammer) rise while turbine speed (runaway) reduce, else the head reduce while the turbine speed rise. With variation of the generator inertia (±20%) that was examined, the head rise and turbine speed rise both vary by cca.10%. Before a turbine manufacturer has been contracted, the generator inertia often has to be assumed. Because of this, it is important to investigate the sensitivity of the analysis results to variations in inertia. For the different guide vanes closing time investigated, there was a significant variation in the all output conditions for the turbine. This modeling parameter is main criteria which directly affect to the so-called guaranteed control values of the HPP, allowed increase of the head (water hammer) and allowed increase of the rotational speed (runaway). Therefore, it is necessary to define the guide vanes minimum closing time, so that the maximum value of the pressure(head) at the turbine and the maximum value of the turbine’s rotational speed be within permissible limits i.e. not exceed the guaranteed control values. To evaluate the influence of the guide vanes closing time on the guaranteed control values, it’s necessary to perform series of computations for different values of the guide vanes closing time. For example (see Table 4), if the guide vanes closing time is 6 [s] (linearly closing-Scenario D1) then the increase of the head (water hammer) at the turbine is cca.63% (Hmax=159.53 [m]) higher compared to the hydrostatic head H0 = 98 [m], while the increase of the turbine rotational speed (runaway) is cca.38% higher (nmax=413.20 [min-1 ]) compared to the rated value of the rotational speed (n0=300 [min-1 ]). These values for the increase the head and rotational speed must be (limited) smaller than the guarantee control values (Hmax<Hguar., nmax<nguar.). Thus, shortest possible guide vanes closing time can be determined. With variation the throttling coefficient (or cross section area in the junction) of the surge tank significant variation in water level oscillation is obtained. The maximum and minimum water level oscillation varying by over 10%. By examining Fig.16 and Table 4 can be concluded that the higher throttling coefficient reduce the variation of water level oscillation in the surge tank. Varying the throttling coefficient had a negligible effect on the turbine rotational speed, while turbine inlet head(max/min) varied by approximately 2%. In this case study the variations in pipe friction factor resulted in notable changes in all turbine outputs. Of additional interest is the possible variation in turbine head from the initially(steady state) estimated “base case A”. According Fig.17, Fig. 18 and Fig . 19 can be concluded that the lower pipe friction is likely to lead to higher pressure peaks at the turbine inlet, turbine speed increase, and variation of water level in the surge tank. VI. CONCLUSION In this paper, sensitivity of transient phenomena analysis of the HPP with variation in modeling parameters such as pipeline friction factor, wave Scenario No. Rotational speed nmax Maximum head Hmax Minimum head Hmin Maximum oscillation Zmax Minimum oscillation Zmin (min-1 ) (m) (m) (m) (m) 1 A (Base case) 430.90 146.70 89.86 108.20 90.71 2 B1 431.00 147.10 90.19 108.20 90.71 3 B2 430.60 146.43 89.64 108.20 90.74 4 C1 444.80 144.10 90.00 108.20 90.71 5 C2 418.70 149.91 89.49 108.17 90.74 6 D1 413.20 159.53 77.18 109.18 89.98 7 D2 423.10 149.75 82.48 108.81 90.25 8 D3 438.10 142.55 90.95 107.11 91.59 9 E1 430.70 146.46 88.48 108.69 89.82 10 E2 433.50 150.20 92.17 99.91 97.66 11 F1 429.80 146.33 89.98 108.11 90.89 12 F2 432.10 147.13 89.61 108.33 90.50
  • 9. Viktor Iliev et al. Int. Journal of Engineering Research and Applications www.ijera.com ISSN: 2248-9622, Vol. 5, Issue 8, (Part - 5) August 2015, pp.265-273 www.ijera.com 273 | P a g e speed, surge tank throttling coefficient, turbine guide vanes closing and generator inertia is presented. Numerical modeling and computation of transient phenomena of the HPP during emergency shutdown for base case was first investigated. The reliability of the numerical simulation is confirmed by comparison of the computation results with experimental data obtained. Each modeling input parameters have been based on the maximum and minimum values. In the base case each modeling parameters have a best estimate values. By transient phenomena analysis can be concluded that some modeling parameters are likely to have a significant impact on the computation results of a transient analysis than others. Future research may be seen in investigated of the influence of others parameters of the analysis. These parameters can be following: time step iteration of the computation, unit characteristics(hill chart), the effect of discrete loss (junctions, bends) etc. REFERENCES [1] S. Mario “Pipeline hydro-dynamics” (Croatian), Faculty of Mechanical Engineering and Naval Architecture, Zagreb, 2005. [2] V. Iliev “Analysis of the influence of the unsteady phenomena in the intake structures, penstocks and units of the hydro power plants during transient regimes”, Master Thesis, Faculty of Mechanical Engineering, Skopje-Macedonia, 2011. [3] A. B. Almeida, E. Koelle (1992): Fluid Transients in Pipe Networks, C. M. P., Elsevier. [4] M. Hanif Chaudry “Applied Hydraulic Transients”, British Columbia Hydro and Power Authority Vancouver, Canada, 1979. [5] E. B. Wylie, Victor L. Streeter “Fluid Transients”, University of Michigan, 2001. [6] Charles Jaeger “Fluid Transients in Hydro- Electric Engineering Practise”, University of Glasgow, 1977. [7] Christophe Nicolet “Hydroacoustic modelling and numerical simulation of unsteady operation of hydroelectric systems” A La Faculte Sciences Et Techniques De Lingenieur, Labaratoire de machines hydrauliques, Thesis No 3751, Lausanne 2007.