This document provides information on various intelligent control, protection, and automation solutions from Novatek Electro, including single and three phase voltage protection relays, timers, motor protection devices, temperature controllers, and protocol converters. The relays and devices monitor voltage, current, temperature and other parameters and provide protection for electrical equipment and machinery from faults like over/under voltage, overloads, phase issues, and temperature abnormalities. They feature digital displays, adjustable settings, communication interfaces, and monitoring software.
2. SINGLE PHASE VOLTAGE PROTECTION RELAYS
RN-111М
DIN RAIL MOUNTING
RN-113
FOR THE PROTECTION OF SINGLE PHASE POWER SUPPLY
CONSUMING EQUIPMENTS AND MACHINERY –
TO PROTECT THEM FROM UNALLOWABLE VOLTAGE DROPS AND
FLUCTUCATIONS
PROTECTION FROM OVER & UNDER VOLTAGE; NEUTRAL BREAK;
SELECTABLE OPERATION ONLY AS OVER/UNDER VOLTAGE.
RN-111M UP TO 3.5kW, RN-113 UP TO 7KW DIRECTLY.
CAN HANDLE ANY LOAD VALUE THROUGH A MAGNETIC CONTACTOR
DIGITAL DISPLAY OF INPUT VOLTAGE & SETTING VALUES;
SELECTABLE AUTO RESET TIME DELAY (5 – 900 sec)
RN-102
EASY WALL MOUNTING INSTALLATION
3. Single Phase Voltage Monitoring Relays
• Power consumption up to 3.5KW (16A Relay)
• Current overload
• Over & Under voltage protection
• Protection from the Neutral Break Condition.
• Spike Busting
RN-101М
SINGLE PHASE VOLTAGE PROTECTION RELAYS
4. THREE PHASE VOLTAGE PROTECTION RELAYS
RNPP-301 RNPP -302
RNPP-311 RNPP-311M
THREE PHASE VOLTAGE PROTECTION RELAYS
5. COMPLETE CONTROL OVER THE VOLTAGE PARAMETERS:
BENEFITS AND ADVANTAGES
OVER & UNDER VOLTAGE FAULTS
PHASE LOSS (SINGLE PHASING)
PHASE VOLTAGE IMBALANCE
WRONG PHASE SEQUENCE
PHASE COINCIDENCE (SHORTING OF PHASES)
MAGNETIC CONTACTOR HEALTH MONITORING
PROTECTION FROM NUISANCE TRIPPINGS (TRIPING DELAY & AUTO RESET
DELAY)
TRUE RMS VOLTAGE MONITORING
SELECTABLE PHASE OR LINE VOLTAGE MONITORING
FRONT PANEL INDICATION (DISPLAY)
WIDE OPERATION RANGE AND RELIABLITY
MORE NUMBER OF ADJUSTABLE PARAMETERS (INTRICATE
CUSTOMISATION)
MULTIFUNCTIONAL
6. MULTIFUNCTIONAL TWO CHANNEL TIME RELAY
OPERATION MODES:
•TWO INDEPENDENT CHANNELS.
• PARALLEL CHANNELS OPERATION
• COMBINATION OF CHANNELS
• TIME RANGE IS 100 MILLISECOND TO 10
HOUR.
• TIME DELAY RELAY.
• PULSE RELAY
• PERIODIC (CYCLIC) RELAY.
• SWITCHING CONTROL RELAY
(STAR/DELTA)
• POWER SUPPLY = 240 VAC; AUX.24/48 VDC
REV-201M
MULTIFUNCTIONAL TWO CHANNELTIME RELAY
7. MULTIFUNCTIONAL ASTRO TIMER
OPERATION MODES:
•PRORRAMMABLE UP TO ONE YEAR;
•PERPETUAL REAL TIME CLOCK WITH
LOCATION PARAMETERS (Astro function)
•VOLTAGE PROTECTION RELAY;
•PHOTO SENSORS INPUT;
•2 INDEPENDENT CHANNELS WITH 8 PRESET
PROGRAMS;
•NON-VOLATILE MEMORY CAN STORE UP TO
5000 EVENTS;
•FREE PROGRAMMING SOFTWARE WITH USB
COMMUNICATION;
•LCD DISPLAY ON FRONT PANEL;
•MODE: YEARLY, MONTHLY, WEEKLY, DAILY,
TIME DELAY RELAY, PULSE RELAY.
REV-302
MULTIFUNCTIONAL TWO CHANNEL ASTRO TIMER
9. SINGLE CHANNEL ASTRO TIMER
OPERATION MODES:
• PROGRAMMABLE UP TO ONE YEAR;
• PERPETUAL REAL TIME CLOCK WITH
LOCATION PARAMETERS (ASTRO FUNCTION BY
LATITUDE & LONGITUDE);
• 1 INDDEPENDENT CHANNELS WITH 2 PRESET
PROGRAM;
• NON-VOLATILE MEMORY CAN STORE UP TO 5000
EVENTS;
• OLED GTAPHICAL DISPLAY ON FRONT PANEL;
• VERY EASY TO PROGRAM THROUGH FRONT
BUTTON;
•MODES: YEARLY, WEEKLY, DAILY, SIMPLE
RELAY;
REV-303
SINGLE CHANNEL ASTRO TIMER
10. SEQUENTIAL AND COMBINATION TIMER (TK-415)
BASIC FUNCTIONS :
MICROCONTROLLER CONTROLLED 15
CHANNEL;
SIMPLE CHANGE-OVER BETWEEN
SEQUENTIAL AND COMBINATION TIMER;
7-SEGMENT LED INDICATIONS;
CASCADE CONNECTION OF SEVERAL
DEVICES FOR EXTENDED TOTAL NUMBER OF
CHANNELS;
MEMORIZATION OF DEVICE MODE AFTER
SWITCHING OFF AND PROGRAM OPERATION
RESTART FROM POWER OFF;
TK-415
SEQUENTIAL & COMBINATION TIMER (TK-415)
INPUTS FOR TIMER START AND PAUSE CONTROL;
FAST RESETTING;
COPY OF SETTINGS;.
PROGRAM CAN BE RUN ONLY ONE TIME OR CYCLIC OPERATION POSSIBLE;
RS-232 CONNECTABILITY AND SOFTWARE FOR EASY PROGRAMMING
AND SIMULATION
13. AC MOTOR PROTECTION DEVICES
UBZ-301 PERFORMS COMPLETE MOTOR
PROTECTION IN THE FOLLOWING CASES :
MAINS VOLTAGE OF POOR QUALITY;
SYMMETRICAL /ASSYMETRICAL OVERLOAD
ON PHASE/LINE CURRENT OVERLOAD
DUE TO MECHANICAL MOTOR LOAD;
PROTECTION ON STARTING/OPERATION
CURRENT;
DRY STROKE AND ABSENCE OF THE LOAD
ON
THE MOTOR;
EARTH LEAKAGE PROTECTION WITH
SUBSEQUENT DISABLING OF AUTORESET
MOTOR WINDING INSULATION RESISTANCE
LEVEL TEST BEFORE START;
INDICATION OF THE FAULTS ON A FRONT
PANEL
UBZ-301
AC MOTOR PROTECTION DEVICE
14. NUMERIC AC MOTOR PROTECTION DEVICE
THE UBZ-304 IS DESIGNED TO PROVIDE FULL
PROTECTION TO ANY THREE PHASE AC ELECTRIC
MOTOR (2.5 TO 315 kw) OR (5A TO 630A) IN LT (380 –
440V) RANGE.
THIS DEVICE CONTINUOUSLY MONITORS THE
INCOMING CURRENT & VOLTAGE PARAMETERS
AND IN CASE OF ANY FAULT CONDITION IT WILL
TRIP WITH THE USER PRESET / DEFAULT TIME
DELAY.
UBZ-304 IS FIELD PROGRAMMABLE AND HAS MORE
THAN 70 PARAMETERS FOR CUSTOMISATION
ACORDING TO USER’S REQUIREMENT.
THE DEVICE HAS TWO INBUILT COMMUNICATION
PORT (RS-485 MODBUS & RS-232) FOR REALTIME
MONITORING, REMOTE CONTROL AND SCADA /
DCS INTEGRATION.
UBZ-304
15. 3/23/12
• MAXIMUM CURRENT ON PHASE.
• EARTH LEAKAGE THROUGH CBCT.
• PHASE CURRENT IMBALANCE.
• THERMAL OVERLOAD (i2xrxt).
• DRY RUN (MINIMUM CURRENT).
• ROTOR FAULT/ROTOR LOCKING.
• MINIMUM & MAXIMUM LINE VOLTAGE.
• PHASE LOSS OR SINGLE PHASING.
• LINE VOLTAGE IMBALANCE OR ASYMETRY.
• REVERSE PHASE SEQUENCE.
• PHASE COLLISION OR SHORT CIRCUIT.
• PROTECTION FROM OVER & UNDER FREQUENCY.
• EXTERNAL/INTERNAL THERMAL SENSOR.
• INSULATION RESISTANCE BEFORE MOTOR START.
UBZ-304 PROVIDES FOLLOWING MAIN PROTECTION :
NUMERIC AC MOTOR PROTECTION DEVICE
UBZ-304
16. NUMERIC AC MOTOR PROTECTION DEVICE
UBZ-304
• UBZ-304 HAS BACK-LIT 4 LINE LCD DISPLAY
TO SHOW VOLTAGE, CURRENT, POWER, FAULT
HISTORY RELATED ALL PARAMETER.
• ALSO THIS DEVICE HAS RS232 & RS485
MODBUS COMMUNICATION INTERFACE BUILT-N.
• WE PROVIDE FREE PC SOFTWARE FOR REAL
TIME MONITORING OF MORE THAN 70
PARAMETERS, DATA LOGGING AND REMOTE.
• YOU CAN REMOTELY OPERATE (ON-OFF)
THROUGH COMMUNICATION CHANNELS.
• EASY COMPATIBILITY WITH SCADA AND DCS
SYSTEMS.
UBZ-304 HAS FOLLOWING BENEFIT AND ADVANTAGE :
17. UBZ-302 PROVIDES :
• COMPLETE VOLTAGE/CURRENT/ PHASE
PROTECTION
LONG LASTING START PROTECTION
LOCKED ROTOR AND DRY STROKING
PROTECTION
THERMAL OVERLOAD PROTECTION
MOTOR COILS INSULATION RESISTANCE
PROTECTION.
EARTH LEAKAGE PROTECTION.
2 OUTPUT RELAYS PROVIDE THE POSSIBILITY FOR :
STAR/DELTA SWITCHING OPERATION.
CASCADE MOTOR START (DELAYED STARTING OF MOTOR ONE BY ONE).
REMOTE TRIPPING THROUGH RELAY OUTPUT.
UBZ-304
NUMERIC AC MOTOR PROTECTION DEVICE
18. NUMERIC AC MOTOR PROTECTION DEVICE
UBZ-304 PC SOFTWARE INTERFACE
19. OM-310 PROVIDES :
• TOTAL POWER LOAD CUT-OFF IN CASE OF EXCESSIVE
ACTIVE POWER CONSUMPTION;
PARTIAL POWER LOAD CUT-OFF IN CASE OF
EXCESSIVE REACTIVE POWER (LOSS);
PROTECTION OF THE EQUIPMENT & MACHINERY
FROM FAULTS OF LOW QUALITY POWER SUPPLY;
• MEASUREMENT & INDICATION OF 3 PHASE POWER
SUPPLY PARAMETERS;
• METERING FUNCTIONS, DATALOGGING, REMOTE
OPERATION (DISPATCHER SYSTEM INTEGRATION)
OM-310
BENEFITS AND ADVANTAGES :
ALARM SIGNALIZATION FOR FAULTS, FAULT HISTORY;
BUILT-IN CURRENT TRANSFORMERS AND Pts;
OPERATION AND DATA TRANSMISSION ON RS-232 OR RS-485 MODBUS INTERFACE;
COMPLETE WITH MONITORING, LOGGING AND ANALYSING SOFTWARE;
EMERGENCY STOP BUTTON (DIGITAL INPUT)
NUMERIC POWER MANAGEMENT DEVICE
20. BUILT-IN CURRENT TRANSFORMER;
MAXIMAL CURRENT PROTECTION WITH
INDEPENDENT TIMING;
INDICATION OF CURRENT AND
MAXIMAL VALUES;
POSSIBILITY TO DISABLE AUTORESET.
RMT-101
OPERATION MODES :
DIGITAL AMPER-METER
POWER CONSUMPTION LIMITING RELAY
SELECTION OF THE PRIORITY POWER LOAD
ADVANTAGES AND BENEFITS :
TECHNICAL PARAMETERS :
ADJUSTABLE CURRENT MONITORING RANGE: FROM 0 TO
10 OR 0 TO 100А;
MEASUREMENT ACCURACY: 1%;
OVERCURRENT FAULT TRIPPING TIME DELAY 0 ÷ 300 SEC;
AUTORESET TIME DELAY: 0 ÷ 900 SEC , ∞;
OVERLOAD RELAY RMT-101
21. BASIC APPLICATION AND FUNCTIONS :
ALLOWS TO CONNECT AND OPERATE UP TO 15
INPUT MEASUREMENT CHANNELS :
3 CHANNELS FOR AC VOLTAGE 3-300V MEASUREMENT RANGE;
4 CHANNELS FOR CURRENT REGISTRATION 0-2000А USING EXTERNAL CURRENT
TRANSFORMERS;
2 TEMPERATURE CHANNELS;
2 CHANNELS WITH STANDARD OUTPUT SIGNAL (0/4-20 mА, 0-10V);
4 DIGITAL CHANNELS FOR THE SENSORS WITH DISCRETE (BINARY) OUTPUT.
RPM-416
MINIMUM SAMPLING RATE 1 MILLISECOND;
MEASUREMENT OF RMS AC VOLTAGE LEVEL;
MEASUREMENT OF RMS AC CURRENTS;
TEMPERATURE MEASUREMENT;
COLLECT INFORMATION FROM PRIMARY
TRANSDUCERS WITH STANDARD CURRENT
(4-20 mA) OR VOLTAGE OUTPUTS (0 – 10 V)
RECORD OF THE MEASURED PARAMETERS
AND VALUES ONTO SD CARD AND ETHERNET.
MULTIPURPOSE DATA LOGGER RPM-416
23. AUTO HEALTHY PHASE SELECTOR PEF-301
PEF-301
ELECTRONIC AUTOMATIC HEALTHY PHASE SELECTOR
CONTROL OVER VOLTAGE ON EACH OF
AVAILABLE LINES
SELECTS ANY OF THE LINES WITH REQUIRED
PROPER VOLTAGE PARAMETERS
POWER RESERVATION OF THE RESPONSIBLE
CONSUMERS
COMPACT AUTOMATIC FALLBACK PANEL
OPERATION LOAD UP TO 3.5 KW DIRECTLY
WRONG VOLTAGE FAULT INDICATION
PROTECTION FROM INTERPHASE SWITCHING
OPERATION WITH GENERATORS
BUILT-IN AUTORECLOSING TIMER
AUTOMATIC HEALTHY PHASE SELECTOR PEF-301
24. AUTO HEALTHY PHASE SELECTOR PEF-319
POWER RESERVATION OF THE RESPONSIBLE
CONSUMERS
COMPACT AUTOMATIC FALLBACK PANEL
OPERATION LOAD UP TO 30A DIRECTLY
WRONG VOLTAGE FAULT INDICATION
PROTECTION FROM INTERPHASE SWITCHING
OPERATION WITH GENERATORS
SEVEN SEGMENT LED DISPLAY.
BUILT-IN AUTORECLOSING TIMER
CONTROL OVER VOLTAGE ON
EACH OF AVAILABLE LINES
SELECTS ANY OF THE LINES
WITH REQUIRED PROPER
VOLTAGE PARAMETERS
PEF-319
ELECTRONIC AUTOMATIC HEALTHY PHASE SELECTOR
AUTOMATIC HEALTHY PHASE SELECTOR PEF-319
25. TEMPERATURE CONTROLLER MCK-301
TEMPERATURE CONTROL FOR:
• INDUSTRIAL AIR-CONDITIONING
• REFRIGERATION
• FRUIT-BANANA RIPPENING ROOMS
• TELECOM MOBILE BASE STATION AND ATM
TEMPERATURE CONTROLLERS
BUILT-IN VOLTAGE PROTECTION FROM ALL POSSIBLE VOLTAGE FAULTS
OPERATION WITH SINGLE AND THREE PHASE EQUIPMENT
MCK-301
TEMPERATURE CONTROLLER MCK-301
26. DIGITAL TEMPERATURE CONTROLLER
DIGITAL TEMPERATURE RELAY TR-100
PROVIDES PROTECTION FOR :
• HV MOTORS,
• GENERATORS,
• DRY TYPE HIGH VOLTAGE TRANSFORMERS
TEMPERATURE MEASUREMENT/SCANING ON
4 INPUT CHANNELS;
4 RELAY OUTPUT FOR ALARM, SENSOR FAULT,
COOLING, TRIPPING AND INDICATION OF THE
PARAMETERS
UNIVERSAL POWER INPUT POWER SUPPLY AC/DC FROM 24 TO 255V;
RS-485 INTERFACE AND MODBUS RTU PROTOCOLS OF DATA
TRANSMISSION
BENEFITS :
TR-100
DIGITAL TEMPERATURE CONTROLLER
27. DIGITAL TEMPERATURE CONTROLLER
DIGITAL TEMPERATURE RELAY TR-101
BASIC FUNCTION AND APPLICATIONS :
SCANING TEMPERATURE, MEASUREMENTS
ON 4 CHANNELS WITH USE OF SENSORS;
CONTROLLING TEMPERATURE ACCORDING TO
PROPORTIONAL INTEGRAL DIFFERENTIAL
PRINCIPLE (PID);
LED DIGITAL DISPLAY;
DETECTS A BREAK OR A SHORT CIRCUIT IN THE
CONNECTED SENSORS;
4 INDIVIDUAL RELAY OUTPUTS, ONE FOR EACH
CHANNEL
RS-485 INTERFACE AND MODBUS RTU
PROTOCOLS OF DATA TRANSMISSION
TR-101
DIGITAL TEMPERATURE CONTROLLER
28. BASIC FUNCTION AND APPLICATIONS :
OPERATING SUPPLY VOLTAGE 220 V AC
OR 100-300 DC V
SUPPORTED ETHERNET PROTOCOLS:
MODBUS TCP, HTTP.
MAXIMUM NUMBER OF CONNECTION IS
11.
DATA EXCHANGE INTERFACE OVER THE
MODBUS NETWORK ID RS-485.
INTEGRETED SERVER MODBUS SERVER
AND HTTP SERVER
ET-485
PROTOCOL CONVERTER RS-485 TO ETHERNET
PROTOCOL CONVERTER ET-485
29. PROTOCOL CONVERTER WITH REMOTE OPERATION
PROTOCOL CONVERTER MODBUS RS-485 VIA MOBILE VOMMUNICATION
BASIC FUNCTION AND APPLICATIONS :
FLEXIBLE OPTION OF CONNECTION VIA
WIRE OR WIRELESS COMMUNICARION;
PASSWORD PROTECTED;
DIFFERENT MODE OF DATA
INTERCHANGE VIA MODBUS NETWORK;
PROGRAMMABLE RELAY OUTPUT;
PROGRAMMABL INPUT FOR SENSOR;
POWER OUTPUT FOR SENSOR;
RESERVE POWER SUPPLY INPUT;
SAVE THE COLLECT DATA TO FLASH
MEMORY CARD INCLUDING THE
RESTORING OF TRANSMITTING IN CASE
OF COMMUNICATION BREAK DOWN;
EM-486
PROTOCOL CONVERTER WITH REMOTE OPERATION
30. MOTOR ON-OFF BY MOBILE THROUGH UBZ-304 &
EM-486
EM-486
UBZ-304