SlideShare a Scribd company logo
The Power in Electrical SafetyProduct overview
BENDER Group
2
Safety for man and machine comprises failure-free power supply in order to
ensure uninterrupted operation.
The convincing benefits for operators of electrical installations are
n	Higher operational safety by early detection of potentially critical plant
conditions
n	Comprehensive protection of personnel and equipment against electrical
hazards
n	 Higher productivity
n	Considerable reduction of operating costs
n	 Time and cost-optimised maintenance
Electrical safety for man and machine
Bender monitoring devices have a key role to play in this respect
Costs of
Bender
monitoring
system
Cost
reduction potential
Future
maintenance
costs
Maintenancecosts
Useful life
Current
maintenance
costs
Maintenance
costs in the
transitional period
Bender monitoring
devices to reduce costs in
the long term
Insulation fault
3
Electrical safety
Page
ISOMETER® insulation monitoring devices...............4
for unearthed power supplies (IT systems)
ISOSCAN® insulation fault location systems.............6
for unearthed power supplies (IT systems)
LINETRAXX® measuring and monitoring relays........8
for earthed power supplies (TN and TT systems)
LINETRAXX® Power Quality
and Energy Measurement...........................................9
for transparency in electrical installations
LINETRAXX® residual current monitoring devices...10
for earthed power supplies (TN and TT systems)
LINETRAXX® Residual current monitoring systems ...11
for earthed power supplies (TN and TT systems)
The safety solutions for medical locations..............12
according to IEC 60364-7-710
MEDICS®The safety solutions for medical locations...13
according to EN 60364-7-710 and VDE 0100-710
The safety solutions for medical locations..............14
according to ANSI/NFPA 99
UNIMET® test systems...............................................15
COMTRAXX® system components............................16
central display, alarm indicator and operator units
Support at all stages.................................................18
All-round service for your installation
Bender worldwide.....................................................19
For every application – to suit any requirement
Maximum electrical safety and the associated fault-free
operating processes belong to the central tasks of the
technical management. The increasing demand for power
quality and operational reliability goes hand in hand with
the increase of disturbing factors:
n	Humidity
n	Ageing
n	Temperature
n	Chemicals
n	Dust
n	 Mechanical stress
n	 Mechanical damage
n	 Overvoltage and
undervoltage
n	 Voltage drops
n	 Voltage peaks
n	Harmonics
Bender monitoring systems are your reliable partners
when control and maintenance of electrical lines or
power quality monitoring are concerned.
Fault-currents Leakage-currents Earth-fault
4
ISOMETER® Insulation monitoring devices
For unearthed power supplies (IT systems)
Insulation monitoring in a AC/DC main circuit
Examples of application:
n	Power supplies of complex production processes
n	Control circuits in safety applications
n	Variable-speed drives in rolling mills, conveyor systems
n	 Mobile power generators
n	 Traffic signalling systems
n	Offline loads (pumps, motors)
n	 Medical locations
n	Control circuits in power plants and substations
n	 Power supplies on ships
n	 Photovoltaic systems and much more.
Insulation monitoring devices for signalling earth faults
in IT systems at an early stage.
Unearthed power supplies offer an invaluable advantage
– a first fault does not lead to a disconnection, operating
procedures are not interrupted.
Therefore, IT systems with insulation monitoring are used in
situations that call for a high degree of safety and reliability.
The centrepiece of every IT system is the insulation
monitoring device ISOMETER®.
Mode of operation:
The insulation monitoring device ISOMETER® continuously
monitors the insulation resistance between system and
earth and immediately signals when a specific values is
undershot. This early warning system provides sufficient
time for the cause of the fault to be eliminated - before a
critical operating state has a chance to develop!
Insulation monitoring devices for
main circuits
Insulation monitoring devices
for medium-voltage systems
Insulation monitoring devices for control
circuits
US
Information edge for increased safety and
system availability
5
Convincing benefits:
n	Highest possible availability and reliability
for power supplies
n	 Increased protection against fire and accidents
n	Precise measurement by a patented
AMP measurement method
n	Practical solutions for all applications
n	Significant cost reductions for
servicing and maintenance
EDS46… EDS46…
US see
nameplate
towards
the loads
Measuring current transformer
IT system 1 IT system 2
Measuring current transformer
towards
the loads
US see
nameplate
US see
nameplate
US see
nameplate
k2 k2
Bender solutions allow simple design of complex and/or coupled systems using the ISONet function for controlling the measuring authorisation
of several IRDH575. This has the advantage that no auxiliary contacts for a coupling switch is required.
6
3+PE
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
690/400V
400kVA
690V
1000kVA
690V
1000kVA
690V
1000kVA
690V
1000kVA
690V
55kW
690V
55kW
690V
55kW
690V
COMPACT
NSX 100F
690V
M
G
3~
G
3~
G
3~
G
3~
FC1
FC2
FC3
FC4
FC5
SOFTSTARTER
SOFTSTARTER
M
3~
M
3~
M
3~
M
3~
M
3~
IT
IRDH575
EDS4..
Generator 1
Generator 2
Generator 3
Generator 4
690V /50kA
3+PE
3+PE
3+PE
3+PE
3+PE
3+PE
3+PE
3+PE
3+PE
3+PE
3
3
3
6.3
ISOSCAN® Equipment for insulation fault location
For unearthed power supplies (IT systems)
Stationary and portable equipment for fast insulation
fault localisation.
The basis of ISOSCAN® is the insulation monitoring device
ISOMETER® with integrated locating current injector.
Mode of operation:
In the event of an insulation fault, insulation fault location
will automatically be started.The locating current injector
generates a locating current signal which flows back via the
current path and the PE conductor. The locating current
signal is detected by all measuring current transformers on
this circuit and signalled to the respective insulation fault
locators.
By assigning the measuring current transformer to the
respective circuit, the point of fault can easily, quickly and
reliably be detected via the screen by an electrically skilled
person.
Insulation monitoring device with integrated
equipment for insulation fault location
Portable equipment for insulation fault
location
Insulation fault location on
expanded IT systems is a time-
consuming and costly affair.
The solution: Insulation fault
location systems (EDS).
For installations with sub-circuits, portable insulation fault
location systems are available.
Current clamps are placed around the wires of the relevant
outgoing circuits and the locating current signals are
checked and in this way the faulty outgoing circuit/location
can be identified.
Convincing benefits:
n	Automatic insulation fault location during operation –
without disconnection
n	Significantly lower outlays in terms of personnel and
time due to precise insulation fault location
n	Modular system concept for optimal adaptation
to the electrical installation
n	Central administration via LAN/WLAN network
n	 Early fault detection allows scheduled
maintenance
6
7
3
690V
55kW
SOFTSTARTER
M
3~
E
3+PE
Operating principle equipment for insulation fault location
Examples of application:
Main and control circuits
n	 in industrial installations
n	 in power plants and substations
n	 in the food industry
n	 in medical locations
n	 on ships
n	 on offshore platforms
n	 in the chemical industry
n	 in photovoltaic systems
Quick fault localisation
8
Parameters being monitored:
n	Voltage
n	Current
n	Frequency
n	 Phase sequence
n	 Phase failure
n	Unbalance
n	 Loop resistance
n	 Earth fault
n	 Vector shift
n	 ROCOF (df/dt)
LINETRAXX® Measuring and monitoring relays
For earthed power supplies (TN and TT systems)
Measuring and monitoring relays for monitoring
electrical parameters in electrical installations
Bender measuring and monitoring relays monitor different
parameters in main and auxiliary circuits. They provide the
necessary information sufficiently well in advance to detect
and signal faults and disturbances early on or to disconnect
the system immediately in the event of critical system
statuses. That reduces operational interruptions, damage to
property and damage to the system and reduces the costs
substantially.
Convincing benefits (420 series):
n	Two separately adjustable response values/alarm relays
n	 Analogue interface with nominal signal 4-20 mA/0-10 V
n	Automatic pre-parameterisation (PreSet function)
n	Measured value memory for displaying the first
operating value
n	Flexible start-up, response and release times
n	 Continuous self monitoring
n	 Password protection for device setting
n	 Compact design due to a two-module enclosure (36 mm)
Application examples loop monitoring:
n	 Loop monitoring for motors
n	 Loop monitoring for PE conductor interruptions in
electrical installations
n	 Monitoring of earthing systems
Solution for the photovoltaic industry: Network and system
protection (NS protection) acc. to CEI 0-21, VDE-AR-N 4105,
BDEW guideline, DIN V VDE V 0126-1-1/A1, C10/11,
G59/2, G59/3 and G83/2 (LINETRAXX® VMD460)
Measuring and monitoring relays
Detecting and signalling
disturbances – in compliance
with the standards due to
adjustable response values.
Application examples current monitoring:
n	 Current consumption of motors, such as pumps,
elevators, cranes
n	 Monitoring of lighting circuits, heating circuits, charging
stations
n	 Monitoring of emergency lighting
n	 Monitoring of screw conveyors, e.g. in sewage plants
Application examples voltage and frequency monitoring:
n	 Monitoring of voltage-sensitive electrical installations
n	 Switching on and switching off function at a certain
voltage level
n	 Monitoring of stand-by and emergency supply systems
n	 Supply voltage monitoring of portable equipment
n	 Protection of three-phase motors against phase failure
and phase sequence
n	 Transformer protection by detection of non-symmetrical
loading
n	 Mains decoupling electricity generation systems
(NS protection)
9
LINETRAXX® Power Quality and Energy Measurement
For transparency in electrical installations
Monitoring of the power quality
and collection of relevant data for
energy management systems.
The digital universal measuring
devices PEM are suited for recording
and displaying electrical parameters
of electricity networks. The scope of
measurements ranges from currents
and voltages through energy con-
sumption and performance to total
harmonic distortion for voltage quality
assessment.
Convincing benefits:
The collection and evaluation of the
measurement parameters is carried out
by the Condition Monitor COMTRAXX®
CP700.
n	 A platform for unified operation
and parameterisation of a wide
variety of devices
n	 Intuitive use
n	 Interactive help systems instead of
operating manuals
n	 Automatic adaptation to your
installation
n	 Guided support in fault analysis
and for immunisation
n	 User-defined filtering of the
relevant information
Modbus/TCP
Ethernet
BMS 1…12
Modbus/
RTU
Fileserver
L
PEN
PE
L
N
PE
U
I
Modbus/TCP
Modbus/RTU
PAS
U
I
subdistribution 1 subdistribution 2
main distribution
1…12
RCMS
U
I
U
I
U
I
RCMS
Modbus/TCP
Modbus/RTU
Modbus/TCP
PEM5xx PEM5xx
Modbus/RTU
PEM3xx
CP700
3
U
I
Modbus/RTU
PEM3xx
3
PEM7xx PEM7xx
Application diagram linetraxx ®
PowerQualityandEnergyMeasurement
Makes system interactions visible
– to ensure a high availability of
your installation.
10
LINETRAXX® Residual current monitors
For earthed power supplies (TN and TT systems)
Residual current monitors RCM, RCMA for earthed power
supplies (TN/TT systems)
RCM residual current monitors monitor electrical
installations for residual currents resp. fault currents, display
the current measured value and signal when a preset
response value is exceeded.
They can be used either for signalling or for switching.
The devices are primarily used in applications where,
depending on the load structure,
switching off would be undesirable or problematic, e.g.:
n	Fire and property protection in industrial and
functional buildings
n	 Uninterruptible power supply systems
n	Cooling equipment, air conditioning systems
n	Variable-speed drives
n	 Lighting circuits
n	 Medical locations
n	 Safety circuits
n	 Computer systems and many others
Convincing benefits:
n	Significant cost reductions as a result of higher availability
and minimal maintenance costs
n	Higher degree of fire and property protection
n	Universal versions for monitoring AC currents as well as
pulsating and smooth DC fault currents
n	True r.m.s. value measurement (TRMS), therefore
unrelated to waveform
Operating principle Residual current monitor RCM
Residual current monitor with measuring
current transformer
AC/DC sensitive residual current
monitoring modules
Monitors residual currents and
fault currents in all situations
where continuous operation
must be ensured.
Distinguishing features
RCM series:
Type A residual current monitors for monitoring
AC currents (42…2000 Hz) and pulsating DC currents
up to 6 mA.
RCMA series:
Type B residual current monitors for monitoring AC currents,
pulsating and smooth DC currents (0…2000 Hz).
RCMB series residual current monitors:
Measuring current transformers and evaluation unit in a
single module for monitoring AC currents, pulsating and
smooth DC currents (0…500 and 0…1000 Hz). Optionally
available with 2 changeover contacts or analogue interface
4…20 mA.
11
LINETRAXX® Residual current monitoring systems
For earthed power supplies (TN and TT systems)
Residual current monitoring system RCMS for earthed
power supplies (TN/TT systems)
To ensure effective preventive maintenance and a high
level of operational and plant safety
n	 fault currents resp. residual currents,
n	 operating currents,
n	 stray currents and
n	 currents in N and PE conductors
must be monitored continuously, the point of fault must
be localised quickly and the service personnel needs to
be given comprehensive information. The solution for this
task: The multi-channel residual current monitoring system
RCMS. The system records the currents AC pulsed DC and
AC/DC current sensitive as true r.m.s. value. The measured
values are stored in the history memory and are available
there for evaluation purposes. A total of 1080 measuring
points can be monitored, whereby the maximum scanning
time for all channels is 200 ms. This makes it easy to
monitor even time-critical applications that require a
shutdown. Data is exchanged between the devices via a
time-efficient and cost-effective RS-485 interface. Interfaces
with higher-level systems via Ethernet or other field bus
systems can be set up easily.
Typical applications:
n	 Data processing centres, computer systems
n	Industrial, residential and functional buildings
n	 Office and administrative buildings
n	 Power supply and distribution
n	 Technical communication systems
n	 Traffic engineering
n	 TV and radio stations
Operating principle residual current monitoring
Convincing benefits:
n	Continuous monitoring of electrical installations in
compliance with
Betriebssicherheitsverordnung (German ordinance on
industrial safety and health) and the accident prevention
regulation BGV A3 (Germany)
n	High standard of property, fire and plant protection
n	High level of efficiency achieved by avoiding
unexpected downtimes and production stoppages
n	Significantly lower outlays in terms of personnel and
time due to precise insulation fault location
n	Modular system concept for optimal adaptation to the
electrical installation
n	Low maintenance costs achieved by ensuring that
failure-prone components are replaced in good time
n	Continuous monitoring of TN-S power supplies with
high EMC
n	Modular principle that allows systems to be configured
in accordance with application and requirements
n	Central administration via LAN/WAN network
Residual current monitoring system Measuring current transformers
Monitoring of up to
1080 measuring points,
at a maximum scanning
time of 200 ms.
12
AN450
isoMED427P
BMS
STW2
MK2430 MK2430
EDS151
ES710 series
The safety solutions for medical locations
according to IEC 60364-7-710
Application example
Insulation monitoring device
The medical IT system acc. to IEC 60364-7-710 consists of
an isolating transformer, a monitoring device to monitor
insulation resistance, transformer load and temperature
and a remote alarm indicator and test combination,
installed in the operating theatre, or at a manned nurse
station, nearby. Continuous insulation monitoring ensures
that a deterioration in insulation resistance is immediately
detected and signalled but (this is the decisive factor) there
is no power supply interruption and continuity of operation
is guaranteed.
The IT system transformer
In accordance with IEC 61558-2-5, the rated output of the
trans­former shall not be less than 0.5 kVA and shall not
exceed 10 kVA. Single-phase transformers have to be used.
If the supply of three-phase loads is also required, a
separate three phase transformer shall be provided –
secondary voltage must not exceed AC 250 V.
The insulation monitoring device
The insulation monitoring device isoMED427P is a vital
unit to ensure the avail­ability of the IT system. Connected
between system and earth, it con­tin­uously monitors the
insulation resistance. The integrated AMP measuring
principle allows insulation faults with DC components to be
precisely recor­d­ed and indicated.
Simultaneously, the ISOMETER® isoMED427P monitors
the load current and the temperature of the transformer.
Additionally it meets the requirements of IEC 61557-8.
In addition, the isoMED427P includes a feature allowing
insulation fault location, i.e. detecting online the faulty load
(socket) in an intensive care unit or operating theatre in
combination with the insulation fault locator EDS151.
Alarm indicator and test combinations Isolating transformer
Continuous insulation
monitoring for immediate
detection without power supply
interruption.
13
Remote alarm indicator
and operators
MEDICS® – the safety solutions for medical locations
according to IEC 60364-7-710 and DIN VDE 0100-710 (VDE 0100-710)
MEDICS® – to ensure safe and reliable power supply
MEDICS® is a comprehensive, tried and tested system that is
able to realise each task on hand in order to secure the safe
and reliable power supply for medical locations.
Convincing benefits:
n	 Monitoring and control of
•	 Normal power supply (AV)
•	 Safety power supply (SV)
•	 Battery-supported safety power supply (e.g. UPS)
in compliance with the standards
n	 Designed in accordance with the requirements of
applicable standards and monitoring of medical
IT systems
n	 Contains complete features of isoMED427P (Insulation
monitoring device with integrated load and
temperature monitoring and locating current injector)
n	 User-oriented information for technical/medical person-
nel with clear instructions to be followed
n	 Comprehensive range of services throughout the entire
life cycle of the system
n	 Intelligent networking with information and
communication technology – centrally on-site,
decentrally with the SCADA system or monitored by the
manufacturer
n	 Additional safety advantage by ready-to-connect
complete solutions with voluntary testing by TÜV
Süddeutschland
•	 Confirmation that the requirements of the standard
DIN VDE 0100-710 (VDE 0100-710) are met
•	 Certification of the functional safety (SIL2) in
accordance with DIN EN 61508-... (VDE 0802-...)
Typical applications:
n	 Hospitals, clinics
n	 Sanatoriums and health clinics
n	 Residential homes for the elderly, nursing homes
n	 Outpatient surgery in doctors' surgeries
n	 Medical care centres
Changeover for intensive care units with integrated insulation
fault locator (EDS)
Nurse desk Intensive care unit
U1 U2
U3
I3
IL RISO
T
ATICS®
-2-63A-ISO
ϑ
MK
Distribution group 2
ATICS®
-BP
EDS151
BMS
MK
Second
supply line
Preferred
supply line
2 2 2 2 2 2
COMTRAXX®
MK800
Floor-standing
cabinet
Transfer switching and monitoring
devices, 2-pole
14
Line Isolation Monitor (LIM)
The safety solutions for medical locations
according to ANSI/NFPA 99 and CSA Z32
LIM2010
Z, U
THC
COMTRAXX®
MK800
MK800
EDS151
Convincing benefits:
n	 No interference with electrical equipment
n	 Special phase-locking circuitry
for ultimate stability and repeatability
n	 Provision for Remote Indicators
n	 Easy to clean rugged front foil
n	 Digital  Analog Bar Graph Displays
n	 Automatic self-calibration and self-check
n	 Audible alarm volume adjustable via menu
n	 Transformer Load Monitoring (optional)
n	 Transformer overtemperature monitoring (optional)
n	 RS-485/BMS communication port
n	 Several LIMs can be controlled by one Remote
n	 Additional communication devices available:
Web server, eMail client
n	 Insulation fault location system available (optional)
Isolated Power System with Line Isolation Monitor for
hospitals and other critical care areas.
Isolated power systems offer an invaluable advantage:
Early detection allows for critical systems to remain online
in a single fault condition. Bender Isolated Power Panels
provide isolated power to electrical systems in operating
rooms and other critical care areas.
Utilizing the latest in line isolation monitoring technology,
the LIM2010 provides advanced warning of faults to help
reduce downtime and increase operational efficiencies.
The Bender LIM2010 Series LIM complies with UL 1022
in the U.S. and CSA-C22.2 No. 204-M1984 in Canada. The
intent is to include the LIM as part of an isolated power
system that conforms with the applicable requirements
of ANSI/NFPA 99 and ANSI/NFPA 70 in the U.S. and in
accordance with CAN/CSA-C22.2 No. 29-M1989 in Canada.
IT system with load and temperature monitoring
Bender isolated power system
equipment are designed in strict
compliance with UL 1047,
UL 1022, UL 50 and CSA Z32.
Isolated Power Panels
15
Safetytesterforservicepurposes
UNIMET® test systems
Test systems for the electrical safety of medical
electrical devices and electrical equipment
Electrical safety is a key concern when using medical
electrical equipment and portable equipment. To protect
users against any potential electrical hazards, there are
various regulations and laws in place that make regular
testing mandatory.
With the UNIMET® safety testers initial verification at the
manufacturer's plant; periodic testing and testing prior to
first use and tests following maintenance and repairs can
be carried out with ease.
Standard compliant tests acc. to:
n	IEC 60601-1, 3rd edition (optional)
n	 IEC 62353:2007-05
n	 DIN EN 62353 (VDE 0751-1):2008-08
n	 ÖVE/ÖNORM EN 62353:2009-01
n	 DIN VDE 0701-0702:2008-06
n	 ÖVE E8701-1:03-01
Testsystemforelectricbedsandelectrical
equipmentacc.toBGVA3
Light-weight safety tester
for mobile applications
The user-friendly one
amongst the safety testers for
simple testing prior to first use,
periodic testing, ...
Convincing benefits:
n	 Simple operation thanks to user guidance
n	Updating of test dates and multi-client capability
n	Time savings thanks to automated test procedures
n	Device under test classified in accordance with
regulations
n	USB printer interface and TFT display, straightforward
documentation via printer or PC
16
COMTRAXX® System components
Central display, alarm indicator and operator units
Signalling, operation, communication
– Overview of your system
Despite the increasing presence of technology in today's
society – people retain a crucial role. These people need to
be provided with the right information, in the right place
and at the right time, so that they can take prompt and
appropriate action.
The Condition Monitor CP700 meets these central
requirements. It is the central display, alarm indicator and
Application example – BMS system integration
PEM PEM
CP700
I3
U1 U2
U3
M
ATICS®
Ethernet
Web server System overviewVisualisation
ProfiBus-DPDigital In/Out Digital In/Out Modbus RTU
BMS bus
ATICS-2-XXA-ISO
ATICS-4-XXXA-DIO
BMS bus BMS bus BMS bus
KNX/LON
ILTI3
U1 U2
U3
RISO
M
ATICS®
BMS bus
ext. BMS bus
COM460IP COM460IP
MK2430 MK800MK800 TM
Modbus RTU
E-Mail
Report
Parameter
Modbus/TCP
...
Solution for BACnet Solution for OPC
COMTRAXX®
MK800
COMTRAXX®
MK800
Integrated functions
Display, alarm indicator and operator unit
– Web server, gateway and local display
Access to all necessary
information – always and
everywhere via PC.
operator unit from which various devices can be operated
and parameterised in a uniform way, from the ISOMETER®
through RCMS to Power Quality Monitoring – intuitive to
use and supported by an interactive help system. This is
possible through a built-in touchscreen and the integrated
web server.
In addition, the Condition Monitor CP700 and the gateway
COM460IP serve as data providers for higher-level systems.
Gateway with web server
Communication solutions
17
A variety of solutions:
n	 Use of existing IT infrastructure
n	 Provision of messages and measured values for
higher-level systems
Convincing benefits:
Overview of the entire system
n	 Active alarm generation
n	 Simple, direct access to all details relating to the
devices in use
n	 Guided support in fault analysis
n	 Easy documentation of measured values and device
parameters
n	 User-definable visualisation
n	 Displaying an overview the contents of which
takes up more than one page
n	 Active alarm generation
n	 Access to information everywhere
and at all times via PC
n	 Integration of third-party devices
n	 Viable for the future by improving
and expanding the functionality by
means of software updates
Representation of device data on the touch screen (COMTRAXX® CP700)
18
Support at all stages
All-round service for your installation: Remote, by phone, on-site
Competent service for maximum
safety and high availability of
your installation
ExpansionModernisatio
n
Planning  Concept
S
electionofdevicesProjectscheduling
Operatio
n

Maintenance Installation  Com
m
issioning
From planning to modernisation – Our know-how and our expertise is at your
disposal in all project phases.
Furthermore, our first-class service ensures you the maximum safety for your
electrical installations.
The service we offer range from telephone support through repairs to on-site
service – with state-of-the-art measuring devices and professional employees.
Many service activities, fault clearance, but also analysis and inspections, can be
carried out by remote maintenance – no technician needs to be on-site, saving
you time and money.
Convincing benefits:
n	 High availability of your installation by responding faster to fault messages
n	 Automatic control, analysis, correction, readjustments/updates are possible
n	 Competent assistance on changing settings and with updates
n	 Regular checking of your installations/power quality/monitoring devices
n	 Significant cost reduction by reduced downtimes and shorter service times
Ex
pan
OperationMaintenance
I
nstallation
19
Bender worldwide
Argentina
Australia
Austria
Bahrain
Bosnia and Herzegovina
Brazil
Bulgaria
Canada
Chile
China
Colombia
Croatia
Czech Republic
Denmark
Egypt
Estonia
Finland
France
Germany
Great Britain
Greece
Hong Kong
Hungary
Iceland
India
Indonesia
Iran
Ireland
Israel
Italy
Japan
Jordan
Kuwait
Latvia
Lebanon
Lithuania
Macedonia
Malaysia
Moldova
Montenegro
New Zealand
Norway
Pakistan
Poland
Portugal
Qatar
Romania
Russia
Saudi Arabia
Serbia
Singapore
Slovakia
Slovenia
South Africa
South Korea
Spain
Sri Lanka
Sweden
Switzerland
Syria
Tadzhikistan
Taiwan
Thailand
The Netherlands
The Philippines
The United States of America
Turkey
United Arab Emirates
Uruguay
Venezuela
Vietnam
Yemen
Bender GmbH  Co. KG
P.O. Box 1161 • 35301 Grünberg • Germany
Londorfer Straße 65 • 35305 Grünberg • Germany
Tel.: +49 6401 807-0 • Fax: +49 6401 807-259
E-Mail: info@bender.de • www.bender.de
2105en/03.2014/MSa/2500/JD-Druck/©BenderGmbHCo.KG,Germany–Subjecttochange!Thespecifiedstandardstakeintoaccounttheversionthatwasvalidatthetimeofprinting.
Pictures: Fotolia (© Oleg Fedorenko), iStock (© beerkoff, © grybaz, © Teun van den Dries), Thinkstock (© Manfredini Mauro), Fraport AG and Bender archives.
BENDER Group

More Related Content

What's hot

Installing, Programming & Commissioning of Power System Protection Relays and...
Installing, Programming & Commissioning of Power System Protection Relays and...Installing, Programming & Commissioning of Power System Protection Relays and...
Installing, Programming & Commissioning of Power System Protection Relays and...Living Online
 
COPS: An Arresting Look at NEC Article 708
COPS: An Arresting Look at NEC Article 708COPS: An Arresting Look at NEC Article 708
COPS: An Arresting Look at NEC Article 708michaeljmack
 
FUNDAMENTALS OF POWER SYSTEM PROTECTION
FUNDAMENTALS OF POWER SYSTEM PROTECTIONFUNDAMENTALS OF POWER SYSTEM PROTECTION
FUNDAMENTALS OF POWER SYSTEM PROTECTIONPower System Operation
 
Short-Circuit Protective Device Coordination & Arc Flash Analysis
Short-Circuit Protective Device Coordination & Arc Flash AnalysisShort-Circuit Protective Device Coordination & Arc Flash Analysis
Short-Circuit Protective Device Coordination & Arc Flash AnalysisPower System Operation
 
Practical Power System Protection for Engineers and Technicians
Practical Power System Protection for Engineers and TechniciansPractical Power System Protection for Engineers and Technicians
Practical Power System Protection for Engineers and TechniciansLiving Online
 
Advanced Network Solutions for Electric Power Application
Advanced Network Solutions for Electric Power ApplicationAdvanced Network Solutions for Electric Power Application
Advanced Network Solutions for Electric Power Applicationchowfei
 
Power System Protection (Primary & Backup)
Power System Protection (Primary & Backup)Power System Protection (Primary & Backup)
Power System Protection (Primary & Backup)Kamran Gillani
 
Access control basics-9
Access control basics-9Access control basics-9
Access control basics-9grantlerc
 
Power system protection_lecture_notes
Power system protection_lecture_notesPower system protection_lecture_notes
Power system protection_lecture_noteslcm3766l
 
Power system protection
Power system protectionPower system protection
Power system protectionAnu Priya
 
Power System Protection Technique: A Review
Power System Protection Technique: A ReviewPower System Protection Technique: A Review
Power System Protection Technique: A Reviewsahid raja khan
 
1.9 protection of power system
1.9 protection of power system1.9 protection of power system
1.9 protection of power systemW3Edify
 
Case study - Elektro Gorenjska
Case study - Elektro GorenjskaCase study - Elektro Gorenjska
Case study - Elektro GorenjskaZiga Mrak
 
Getting the Most out of your Electrical Room
Getting the Most out of your Electrical RoomGetting the Most out of your Electrical Room
Getting the Most out of your Electrical Roommichaeljmack
 
Hioki 3196 Power Quality Analyzer Datasheet Manual
Hioki 3196 Power Quality Analyzer Datasheet ManualHioki 3196 Power Quality Analyzer Datasheet Manual
Hioki 3196 Power Quality Analyzer Datasheet ManualAngus Sankaran
 
What is Power Quality?
What is Power Quality?What is Power Quality?
What is Power Quality?svergin
 

What's hot (19)

Installing, Programming & Commissioning of Power System Protection Relays and...
Installing, Programming & Commissioning of Power System Protection Relays and...Installing, Programming & Commissioning of Power System Protection Relays and...
Installing, Programming & Commissioning of Power System Protection Relays and...
 
COPS: An Arresting Look at NEC Article 708
COPS: An Arresting Look at NEC Article 708COPS: An Arresting Look at NEC Article 708
COPS: An Arresting Look at NEC Article 708
 
FUNDAMENTALS OF POWER SYSTEM PROTECTION
FUNDAMENTALS OF POWER SYSTEM PROTECTIONFUNDAMENTALS OF POWER SYSTEM PROTECTION
FUNDAMENTALS OF POWER SYSTEM PROTECTION
 
Short-Circuit Protective Device Coordination & Arc Flash Analysis
Short-Circuit Protective Device Coordination & Arc Flash AnalysisShort-Circuit Protective Device Coordination & Arc Flash Analysis
Short-Circuit Protective Device Coordination & Arc Flash Analysis
 
Practical Power System Protection for Engineers and Technicians
Practical Power System Protection for Engineers and TechniciansPractical Power System Protection for Engineers and Technicians
Practical Power System Protection for Engineers and Technicians
 
Advanced Network Solutions for Electric Power Application
Advanced Network Solutions for Electric Power ApplicationAdvanced Network Solutions for Electric Power Application
Advanced Network Solutions for Electric Power Application
 
Power System Protection (Primary & Backup)
Power System Protection (Primary & Backup)Power System Protection (Primary & Backup)
Power System Protection (Primary & Backup)
 
Access control basics-9
Access control basics-9Access control basics-9
Access control basics-9
 
Power system protection_lecture_notes
Power system protection_lecture_notesPower system protection_lecture_notes
Power system protection_lecture_notes
 
Power system protection
Power system protectionPower system protection
Power system protection
 
Power System Protection Technique: A Review
Power System Protection Technique: A ReviewPower System Protection Technique: A Review
Power System Protection Technique: A Review
 
1.9 protection of power system
1.9 protection of power system1.9 protection of power system
1.9 protection of power system
 
Case study - Elektro Gorenjska
Case study - Elektro GorenjskaCase study - Elektro Gorenjska
Case study - Elektro Gorenjska
 
Getting the Most out of your Electrical Room
Getting the Most out of your Electrical RoomGetting the Most out of your Electrical Room
Getting the Most out of your Electrical Room
 
S123 b30u
S123 b30uS123 b30u
S123 b30u
 
Cylinder Sensor Brochure
Cylinder Sensor BrochureCylinder Sensor Brochure
Cylinder Sensor Brochure
 
Hioki 3196 Power Quality Analyzer Datasheet Manual
Hioki 3196 Power Quality Analyzer Datasheet ManualHioki 3196 Power Quality Analyzer Datasheet Manual
Hioki 3196 Power Quality Analyzer Datasheet Manual
 
128 electrical power-protection_guide
128 electrical power-protection_guide128 electrical power-protection_guide
128 electrical power-protection_guide
 
What is Power Quality?
What is Power Quality?What is Power Quality?
What is Power Quality?
 

Viewers also liked

S&B Parking Operators
S&B Parking OperatorsS&B Parking Operators
S&B Parking OperatorsSB Ibérica
 
Examen trimestra diego reyes
Examen trimestra  diego reyesExamen trimestra  diego reyes
Examen trimestra diego reyesDiego Reyes
 
2012 Email Evolution Sneak Peak Webinar: Part 1
2012 Email Evolution Sneak Peak Webinar: Part 12012 Email Evolution Sneak Peak Webinar: Part 1
2012 Email Evolution Sneak Peak Webinar: Part 1Vivastream
 
Curso de Alta Formación en Marketing para Empresas de Servicios
Curso de Alta Formación en Marketing para Empresas de ServiciosCurso de Alta Formación en Marketing para Empresas de Servicios
Curso de Alta Formación en Marketing para Empresas de ServiciosUnibo
 
Profile.e (yuki sato)0529
Profile.e (yuki sato)0529Profile.e (yuki sato)0529
Profile.e (yuki sato)0529Sato Yuki
 
fluke presentation voicemail on email – cisco
fluke presentation voicemail on email – ciscofluke presentation voicemail on email – cisco
fluke presentation voicemail on email – ciscoFluke Infotech
 
(Self) Publishing
(Self) Publishing(Self) Publishing
(Self) PublishingVlad Micu
 
Servicio Eiden : Opinan nuestros clientes
Servicio Eiden : Opinan nuestros clientesServicio Eiden : Opinan nuestros clientes
Servicio Eiden : Opinan nuestros clientesSantiago Trevisán
 
Status Www Undersøgelse Udenpix
Status Www Undersøgelse UdenpixStatus Www Undersøgelse Udenpix
Status Www Undersøgelse UdenpixElisabeth Tejlmand
 
Brand boost by wildtangent
Brand boost by wildtangentBrand boost by wildtangent
Brand boost by wildtangentWildTangent
 
Update on the ELIXIR UK node by Chris Ponting
Update on the ELIXIR UK node by Chris PontingUpdate on the ELIXIR UK node by Chris Ponting
Update on the ELIXIR UK node by Chris PontingELIXIR UK
 
Da schau her! Augenfreundliche Gestaltung von e-Learning Kursen
Da schau her! Augenfreundliche Gestaltung von e-Learning KursenDa schau her! Augenfreundliche Gestaltung von e-Learning Kursen
Da schau her! Augenfreundliche Gestaltung von e-Learning KursenGergely Rakoczi
 
Droidcon ES '16 - How to fail going offline
Droidcon ES '16 - How to fail going offlineDroidcon ES '16 - How to fail going offline
Droidcon ES '16 - How to fail going offlineJavier de Pedro López
 
Parroquia de San Pedro y San Pablo (Cabanillas del Campo)
Parroquia de San Pedro y San Pablo (Cabanillas del Campo)Parroquia de San Pedro y San Pablo (Cabanillas del Campo)
Parroquia de San Pedro y San Pablo (Cabanillas del Campo)Javier Lozano
 

Viewers also liked (20)

Jsa presentation
Jsa presentationJsa presentation
Jsa presentation
 
Power tools safety
Power tools safetyPower tools safety
Power tools safety
 
Harness Training- Increase Safety with Work at Height
Harness Training- Increase Safety with Work at HeightHarness Training- Increase Safety with Work at Height
Harness Training- Increase Safety with Work at Height
 
Tarea 1 e busines
Tarea 1 e businesTarea 1 e busines
Tarea 1 e busines
 
S&B Parking Operators
S&B Parking OperatorsS&B Parking Operators
S&B Parking Operators
 
Examen trimestra diego reyes
Examen trimestra  diego reyesExamen trimestra  diego reyes
Examen trimestra diego reyes
 
2012 Email Evolution Sneak Peak Webinar: Part 1
2012 Email Evolution Sneak Peak Webinar: Part 12012 Email Evolution Sneak Peak Webinar: Part 1
2012 Email Evolution Sneak Peak Webinar: Part 1
 
Curso de Alta Formación en Marketing para Empresas de Servicios
Curso de Alta Formación en Marketing para Empresas de ServiciosCurso de Alta Formación en Marketing para Empresas de Servicios
Curso de Alta Formación en Marketing para Empresas de Servicios
 
Profile.e (yuki sato)0529
Profile.e (yuki sato)0529Profile.e (yuki sato)0529
Profile.e (yuki sato)0529
 
fluke presentation voicemail on email – cisco
fluke presentation voicemail on email – ciscofluke presentation voicemail on email – cisco
fluke presentation voicemail on email – cisco
 
(Self) Publishing
(Self) Publishing(Self) Publishing
(Self) Publishing
 
Servicio Eiden : Opinan nuestros clientes
Servicio Eiden : Opinan nuestros clientesServicio Eiden : Opinan nuestros clientes
Servicio Eiden : Opinan nuestros clientes
 
Status Www Undersøgelse Udenpix
Status Www Undersøgelse UdenpixStatus Www Undersøgelse Udenpix
Status Www Undersøgelse Udenpix
 
CompuSystems Dashboards
CompuSystems DashboardsCompuSystems Dashboards
CompuSystems Dashboards
 
Brand boost by wildtangent
Brand boost by wildtangentBrand boost by wildtangent
Brand boost by wildtangent
 
Update on the ELIXIR UK node by Chris Ponting
Update on the ELIXIR UK node by Chris PontingUpdate on the ELIXIR UK node by Chris Ponting
Update on the ELIXIR UK node by Chris Ponting
 
Da schau her! Augenfreundliche Gestaltung von e-Learning Kursen
Da schau her! Augenfreundliche Gestaltung von e-Learning KursenDa schau her! Augenfreundliche Gestaltung von e-Learning Kursen
Da schau her! Augenfreundliche Gestaltung von e-Learning Kursen
 
Droidcon ES '16 - How to fail going offline
Droidcon ES '16 - How to fail going offlineDroidcon ES '16 - How to fail going offline
Droidcon ES '16 - How to fail going offline
 
Parroquia de San Pedro y San Pablo (Cabanillas del Campo)
Parroquia de San Pedro y San Pablo (Cabanillas del Campo)Parroquia de San Pedro y San Pablo (Cabanillas del Campo)
Parroquia de San Pedro y San Pablo (Cabanillas del Campo)
 
Estudio earcas
Estudio earcasEstudio earcas
Estudio earcas
 

Similar to Electrical-Safety-Productoverview_PROSP_en

Wind Turbine programme
Wind Turbine programmeWind Turbine programme
Wind Turbine programmeMinka Grdesic
 
Prueba eléctrica de motores y generadores eléctricos - Calidad de Energía el...
Prueba eléctrica de motores  y generadores eléctricos - Calidad de Energía el...Prueba eléctrica de motores  y generadores eléctricos - Calidad de Energía el...
Prueba eléctrica de motores y generadores eléctricos - Calidad de Energía el...JOe Torres Palomino
 
Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)Minka Grdesic
 
The Intellectual Automated Substation
The Intellectual Automated SubstationThe Intellectual Automated Substation
The Intellectual Automated Substationijtsrd
 
IT (Floating) System
IT (Floating) SystemIT (Floating) System
IT (Floating) SystemWakkas Mirza
 
Electrical Safety Catalogue - Stonytrack 1
Electrical Safety Catalogue - Stonytrack 1Electrical Safety Catalogue - Stonytrack 1
Electrical Safety Catalogue - Stonytrack 1md bayzid
 
Mitsubishi digital protection relay melpro a series dienhathe.vn
Mitsubishi digital protection relay melpro a series dienhathe.vnMitsubishi digital protection relay melpro a series dienhathe.vn
Mitsubishi digital protection relay melpro a series dienhathe.vnDien Ha The
 
4983 br001 -en-p
4983 br001 -en-p4983 br001 -en-p
4983 br001 -en-pnguyensun
 
Bussmann By Eaton - Surge Protection Devices Catalogue
Bussmann By Eaton - Surge Protection Devices CatalogueBussmann By Eaton - Surge Protection Devices Catalogue
Bussmann By Eaton - Surge Protection Devices CatalogueThorne & Derrick International
 
Novatek Electro (India) Pvt. Ltd., Delhi, Microcontroller Based Devices
Novatek Electro (India) Pvt. Ltd., Delhi, Microcontroller Based Devices Novatek Electro (India) Pvt. Ltd., Delhi, Microcontroller Based Devices
Novatek Electro (India) Pvt. Ltd., Delhi, Microcontroller Based Devices IndiaMART InterMESH Limited
 
IRJET- Real Time Transformer Health Monitoring System using GSM and IoT
IRJET-  	  Real Time Transformer Health Monitoring System using GSM and IoTIRJET-  	  Real Time Transformer Health Monitoring System using GSM and IoT
IRJET- Real Time Transformer Health Monitoring System using GSM and IoTIRJET Journal
 
Techimp Products and Services Portfolio
Techimp Products and Services PortfolioTechimp Products and Services Portfolio
Techimp Products and Services PortfolioTechimp HQ
 
Omnik micro-inverter-m248-m500-kit
Omnik micro-inverter-m248-m500-kitOmnik micro-inverter-m248-m500-kit
Omnik micro-inverter-m248-m500-kitOmnik Solar
 
Implementation of techniques to improve energy efficiency and safety of elect...
Implementation of techniques to improve energy efficiency and safety of elect...Implementation of techniques to improve energy efficiency and safety of elect...
Implementation of techniques to improve energy efficiency and safety of elect...Istiak Mahmood
 
IRJET - Automated Monitoring Test Rig for Circuit Breaker Operation
IRJET -  	  Automated Monitoring Test Rig for Circuit Breaker OperationIRJET -  	  Automated Monitoring Test Rig for Circuit Breaker Operation
IRJET - Automated Monitoring Test Rig for Circuit Breaker OperationIRJET Journal
 
Monitoring of Distribution Transformer Parameters Using Plc
Monitoring of Distribution Transformer Parameters Using PlcMonitoring of Distribution Transformer Parameters Using Plc
Monitoring of Distribution Transformer Parameters Using PlcIRJET Journal
 

Similar to Electrical-Safety-Productoverview_PROSP_en (20)

Wind Turbine programme
Wind Turbine programmeWind Turbine programme
Wind Turbine programme
 
Wind Energy
Wind EnergyWind Energy
Wind Energy
 
Prueba eléctrica de motores y generadores eléctricos - Calidad de Energía el...
Prueba eléctrica de motores  y generadores eléctricos - Calidad de Energía el...Prueba eléctrica de motores  y generadores eléctricos - Calidad de Energía el...
Prueba eléctrica de motores y generadores eléctricos - Calidad de Energía el...
 
Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)
 
The Intellectual Automated Substation
The Intellectual Automated SubstationThe Intellectual Automated Substation
The Intellectual Automated Substation
 
IT (Floating) System
IT (Floating) SystemIT (Floating) System
IT (Floating) System
 
Electrical Safety Catalogue - Stonytrack 1
Electrical Safety Catalogue - Stonytrack 1Electrical Safety Catalogue - Stonytrack 1
Electrical Safety Catalogue - Stonytrack 1
 
Mitsubishi digital protection relay melpro a series dienhathe.vn
Mitsubishi digital protection relay melpro a series dienhathe.vnMitsubishi digital protection relay melpro a series dienhathe.vn
Mitsubishi digital protection relay melpro a series dienhathe.vn
 
4983 br001 -en-p
4983 br001 -en-p4983 br001 -en-p
4983 br001 -en-p
 
Bussmann By Eaton - Surge Protection Devices Catalogue
Bussmann By Eaton - Surge Protection Devices CatalogueBussmann By Eaton - Surge Protection Devices Catalogue
Bussmann By Eaton - Surge Protection Devices Catalogue
 
Thông số kĩ thuật siemens monitoring devices
Thông số kĩ thuật siemens monitoring devicesThông số kĩ thuật siemens monitoring devices
Thông số kĩ thuật siemens monitoring devices
 
Novatek Electro (India) Pvt. Ltd., Delhi, Microcontroller Based Devices
Novatek Electro (India) Pvt. Ltd., Delhi, Microcontroller Based Devices Novatek Electro (India) Pvt. Ltd., Delhi, Microcontroller Based Devices
Novatek Electro (India) Pvt. Ltd., Delhi, Microcontroller Based Devices
 
Cl novatek
Cl novatekCl novatek
Cl novatek
 
IRJET- Real Time Transformer Health Monitoring System using GSM and IoT
IRJET-  	  Real Time Transformer Health Monitoring System using GSM and IoTIRJET-  	  Real Time Transformer Health Monitoring System using GSM and IoT
IRJET- Real Time Transformer Health Monitoring System using GSM and IoT
 
Techimp Products and Services Portfolio
Techimp Products and Services PortfolioTechimp Products and Services Portfolio
Techimp Products and Services Portfolio
 
ritesh (2)
ritesh (2)ritesh (2)
ritesh (2)
 
Omnik micro-inverter-m248-m500-kit
Omnik micro-inverter-m248-m500-kitOmnik micro-inverter-m248-m500-kit
Omnik micro-inverter-m248-m500-kit
 
Implementation of techniques to improve energy efficiency and safety of elect...
Implementation of techniques to improve energy efficiency and safety of elect...Implementation of techniques to improve energy efficiency and safety of elect...
Implementation of techniques to improve energy efficiency and safety of elect...
 
IRJET - Automated Monitoring Test Rig for Circuit Breaker Operation
IRJET -  	  Automated Monitoring Test Rig for Circuit Breaker OperationIRJET -  	  Automated Monitoring Test Rig for Circuit Breaker Operation
IRJET - Automated Monitoring Test Rig for Circuit Breaker Operation
 
Monitoring of Distribution Transformer Parameters Using Plc
Monitoring of Distribution Transformer Parameters Using PlcMonitoring of Distribution Transformer Parameters Using Plc
Monitoring of Distribution Transformer Parameters Using Plc
 

Electrical-Safety-Productoverview_PROSP_en

  • 1. The Power in Electrical SafetyProduct overview BENDER Group
  • 2. 2 Safety for man and machine comprises failure-free power supply in order to ensure uninterrupted operation. The convincing benefits for operators of electrical installations are n Higher operational safety by early detection of potentially critical plant conditions n Comprehensive protection of personnel and equipment against electrical hazards n Higher productivity n Considerable reduction of operating costs n Time and cost-optimised maintenance Electrical safety for man and machine Bender monitoring devices have a key role to play in this respect Costs of Bender monitoring system Cost reduction potential Future maintenance costs Maintenancecosts Useful life Current maintenance costs Maintenance costs in the transitional period Bender monitoring devices to reduce costs in the long term Insulation fault
  • 3. 3 Electrical safety Page ISOMETER® insulation monitoring devices...............4 for unearthed power supplies (IT systems) ISOSCAN® insulation fault location systems.............6 for unearthed power supplies (IT systems) LINETRAXX® measuring and monitoring relays........8 for earthed power supplies (TN and TT systems) LINETRAXX® Power Quality and Energy Measurement...........................................9 for transparency in electrical installations LINETRAXX® residual current monitoring devices...10 for earthed power supplies (TN and TT systems) LINETRAXX® Residual current monitoring systems ...11 for earthed power supplies (TN and TT systems) The safety solutions for medical locations..............12 according to IEC 60364-7-710 MEDICS®The safety solutions for medical locations...13 according to EN 60364-7-710 and VDE 0100-710 The safety solutions for medical locations..............14 according to ANSI/NFPA 99 UNIMET® test systems...............................................15 COMTRAXX® system components............................16 central display, alarm indicator and operator units Support at all stages.................................................18 All-round service for your installation Bender worldwide.....................................................19 For every application – to suit any requirement Maximum electrical safety and the associated fault-free operating processes belong to the central tasks of the technical management. The increasing demand for power quality and operational reliability goes hand in hand with the increase of disturbing factors: n Humidity n Ageing n Temperature n Chemicals n Dust n Mechanical stress n Mechanical damage n Overvoltage and undervoltage n Voltage drops n Voltage peaks n Harmonics Bender monitoring systems are your reliable partners when control and maintenance of electrical lines or power quality monitoring are concerned. Fault-currents Leakage-currents Earth-fault
  • 4. 4 ISOMETER® Insulation monitoring devices For unearthed power supplies (IT systems) Insulation monitoring in a AC/DC main circuit Examples of application: n Power supplies of complex production processes n Control circuits in safety applications n Variable-speed drives in rolling mills, conveyor systems n Mobile power generators n Traffic signalling systems n Offline loads (pumps, motors) n Medical locations n Control circuits in power plants and substations n Power supplies on ships n Photovoltaic systems and much more. Insulation monitoring devices for signalling earth faults in IT systems at an early stage. Unearthed power supplies offer an invaluable advantage – a first fault does not lead to a disconnection, operating procedures are not interrupted. Therefore, IT systems with insulation monitoring are used in situations that call for a high degree of safety and reliability. The centrepiece of every IT system is the insulation monitoring device ISOMETER®. Mode of operation: The insulation monitoring device ISOMETER® continuously monitors the insulation resistance between system and earth and immediately signals when a specific values is undershot. This early warning system provides sufficient time for the cause of the fault to be eliminated - before a critical operating state has a chance to develop! Insulation monitoring devices for main circuits Insulation monitoring devices for medium-voltage systems Insulation monitoring devices for control circuits US Information edge for increased safety and system availability
  • 5. 5 Convincing benefits: n Highest possible availability and reliability for power supplies n Increased protection against fire and accidents n Precise measurement by a patented AMP measurement method n Practical solutions for all applications n Significant cost reductions for servicing and maintenance EDS46… EDS46… US see nameplate towards the loads Measuring current transformer IT system 1 IT system 2 Measuring current transformer towards the loads US see nameplate US see nameplate US see nameplate k2 k2 Bender solutions allow simple design of complex and/or coupled systems using the ISONet function for controlling the measuring authorisation of several IRDH575. This has the advantage that no auxiliary contacts for a coupling switch is required.
  • 6. 6 3+PE 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 690/400V 400kVA 690V 1000kVA 690V 1000kVA 690V 1000kVA 690V 1000kVA 690V 55kW 690V 55kW 690V 55kW 690V COMPACT NSX 100F 690V M G 3~ G 3~ G 3~ G 3~ FC1 FC2 FC3 FC4 FC5 SOFTSTARTER SOFTSTARTER M 3~ M 3~ M 3~ M 3~ M 3~ IT IRDH575 EDS4.. Generator 1 Generator 2 Generator 3 Generator 4 690V /50kA 3+PE 3+PE 3+PE 3+PE 3+PE 3+PE 3+PE 3+PE 3+PE 3+PE 3 3 3 6.3 ISOSCAN® Equipment for insulation fault location For unearthed power supplies (IT systems) Stationary and portable equipment for fast insulation fault localisation. The basis of ISOSCAN® is the insulation monitoring device ISOMETER® with integrated locating current injector. Mode of operation: In the event of an insulation fault, insulation fault location will automatically be started.The locating current injector generates a locating current signal which flows back via the current path and the PE conductor. The locating current signal is detected by all measuring current transformers on this circuit and signalled to the respective insulation fault locators. By assigning the measuring current transformer to the respective circuit, the point of fault can easily, quickly and reliably be detected via the screen by an electrically skilled person. Insulation monitoring device with integrated equipment for insulation fault location Portable equipment for insulation fault location Insulation fault location on expanded IT systems is a time- consuming and costly affair. The solution: Insulation fault location systems (EDS). For installations with sub-circuits, portable insulation fault location systems are available. Current clamps are placed around the wires of the relevant outgoing circuits and the locating current signals are checked and in this way the faulty outgoing circuit/location can be identified. Convincing benefits: n Automatic insulation fault location during operation – without disconnection n Significantly lower outlays in terms of personnel and time due to precise insulation fault location n Modular system concept for optimal adaptation to the electrical installation n Central administration via LAN/WLAN network n Early fault detection allows scheduled maintenance 6
  • 7. 7 3 690V 55kW SOFTSTARTER M 3~ E 3+PE Operating principle equipment for insulation fault location Examples of application: Main and control circuits n in industrial installations n in power plants and substations n in the food industry n in medical locations n on ships n on offshore platforms n in the chemical industry n in photovoltaic systems Quick fault localisation
  • 8. 8 Parameters being monitored: n Voltage n Current n Frequency n Phase sequence n Phase failure n Unbalance n Loop resistance n Earth fault n Vector shift n ROCOF (df/dt) LINETRAXX® Measuring and monitoring relays For earthed power supplies (TN and TT systems) Measuring and monitoring relays for monitoring electrical parameters in electrical installations Bender measuring and monitoring relays monitor different parameters in main and auxiliary circuits. They provide the necessary information sufficiently well in advance to detect and signal faults and disturbances early on or to disconnect the system immediately in the event of critical system statuses. That reduces operational interruptions, damage to property and damage to the system and reduces the costs substantially. Convincing benefits (420 series): n Two separately adjustable response values/alarm relays n Analogue interface with nominal signal 4-20 mA/0-10 V n Automatic pre-parameterisation (PreSet function) n Measured value memory for displaying the first operating value n Flexible start-up, response and release times n Continuous self monitoring n Password protection for device setting n Compact design due to a two-module enclosure (36 mm) Application examples loop monitoring: n Loop monitoring for motors n Loop monitoring for PE conductor interruptions in electrical installations n Monitoring of earthing systems Solution for the photovoltaic industry: Network and system protection (NS protection) acc. to CEI 0-21, VDE-AR-N 4105, BDEW guideline, DIN V VDE V 0126-1-1/A1, C10/11, G59/2, G59/3 and G83/2 (LINETRAXX® VMD460) Measuring and monitoring relays Detecting and signalling disturbances – in compliance with the standards due to adjustable response values. Application examples current monitoring: n Current consumption of motors, such as pumps, elevators, cranes n Monitoring of lighting circuits, heating circuits, charging stations n Monitoring of emergency lighting n Monitoring of screw conveyors, e.g. in sewage plants Application examples voltage and frequency monitoring: n Monitoring of voltage-sensitive electrical installations n Switching on and switching off function at a certain voltage level n Monitoring of stand-by and emergency supply systems n Supply voltage monitoring of portable equipment n Protection of three-phase motors against phase failure and phase sequence n Transformer protection by detection of non-symmetrical loading n Mains decoupling electricity generation systems (NS protection)
  • 9. 9 LINETRAXX® Power Quality and Energy Measurement For transparency in electrical installations Monitoring of the power quality and collection of relevant data for energy management systems. The digital universal measuring devices PEM are suited for recording and displaying electrical parameters of electricity networks. The scope of measurements ranges from currents and voltages through energy con- sumption and performance to total harmonic distortion for voltage quality assessment. Convincing benefits: The collection and evaluation of the measurement parameters is carried out by the Condition Monitor COMTRAXX® CP700. n A platform for unified operation and parameterisation of a wide variety of devices n Intuitive use n Interactive help systems instead of operating manuals n Automatic adaptation to your installation n Guided support in fault analysis and for immunisation n User-defined filtering of the relevant information Modbus/TCP Ethernet BMS 1…12 Modbus/ RTU Fileserver L PEN PE L N PE U I Modbus/TCP Modbus/RTU PAS U I subdistribution 1 subdistribution 2 main distribution 1…12 RCMS U I U I U I RCMS Modbus/TCP Modbus/RTU Modbus/TCP PEM5xx PEM5xx Modbus/RTU PEM3xx CP700 3 U I Modbus/RTU PEM3xx 3 PEM7xx PEM7xx Application diagram linetraxx ® PowerQualityandEnergyMeasurement Makes system interactions visible – to ensure a high availability of your installation.
  • 10. 10 LINETRAXX® Residual current monitors For earthed power supplies (TN and TT systems) Residual current monitors RCM, RCMA for earthed power supplies (TN/TT systems) RCM residual current monitors monitor electrical installations for residual currents resp. fault currents, display the current measured value and signal when a preset response value is exceeded. They can be used either for signalling or for switching. The devices are primarily used in applications where, depending on the load structure, switching off would be undesirable or problematic, e.g.: n Fire and property protection in industrial and functional buildings n Uninterruptible power supply systems n Cooling equipment, air conditioning systems n Variable-speed drives n Lighting circuits n Medical locations n Safety circuits n Computer systems and many others Convincing benefits: n Significant cost reductions as a result of higher availability and minimal maintenance costs n Higher degree of fire and property protection n Universal versions for monitoring AC currents as well as pulsating and smooth DC fault currents n True r.m.s. value measurement (TRMS), therefore unrelated to waveform Operating principle Residual current monitor RCM Residual current monitor with measuring current transformer AC/DC sensitive residual current monitoring modules Monitors residual currents and fault currents in all situations where continuous operation must be ensured. Distinguishing features RCM series: Type A residual current monitors for monitoring AC currents (42…2000 Hz) and pulsating DC currents up to 6 mA. RCMA series: Type B residual current monitors for monitoring AC currents, pulsating and smooth DC currents (0…2000 Hz). RCMB series residual current monitors: Measuring current transformers and evaluation unit in a single module for monitoring AC currents, pulsating and smooth DC currents (0…500 and 0…1000 Hz). Optionally available with 2 changeover contacts or analogue interface 4…20 mA.
  • 11. 11 LINETRAXX® Residual current monitoring systems For earthed power supplies (TN and TT systems) Residual current monitoring system RCMS for earthed power supplies (TN/TT systems) To ensure effective preventive maintenance and a high level of operational and plant safety n fault currents resp. residual currents, n operating currents, n stray currents and n currents in N and PE conductors must be monitored continuously, the point of fault must be localised quickly and the service personnel needs to be given comprehensive information. The solution for this task: The multi-channel residual current monitoring system RCMS. The system records the currents AC pulsed DC and AC/DC current sensitive as true r.m.s. value. The measured values are stored in the history memory and are available there for evaluation purposes. A total of 1080 measuring points can be monitored, whereby the maximum scanning time for all channels is 200 ms. This makes it easy to monitor even time-critical applications that require a shutdown. Data is exchanged between the devices via a time-efficient and cost-effective RS-485 interface. Interfaces with higher-level systems via Ethernet or other field bus systems can be set up easily. Typical applications: n Data processing centres, computer systems n Industrial, residential and functional buildings n Office and administrative buildings n Power supply and distribution n Technical communication systems n Traffic engineering n TV and radio stations Operating principle residual current monitoring Convincing benefits: n Continuous monitoring of electrical installations in compliance with Betriebssicherheitsverordnung (German ordinance on industrial safety and health) and the accident prevention regulation BGV A3 (Germany) n High standard of property, fire and plant protection n High level of efficiency achieved by avoiding unexpected downtimes and production stoppages n Significantly lower outlays in terms of personnel and time due to precise insulation fault location n Modular system concept for optimal adaptation to the electrical installation n Low maintenance costs achieved by ensuring that failure-prone components are replaced in good time n Continuous monitoring of TN-S power supplies with high EMC n Modular principle that allows systems to be configured in accordance with application and requirements n Central administration via LAN/WAN network Residual current monitoring system Measuring current transformers Monitoring of up to 1080 measuring points, at a maximum scanning time of 200 ms.
  • 12. 12 AN450 isoMED427P BMS STW2 MK2430 MK2430 EDS151 ES710 series The safety solutions for medical locations according to IEC 60364-7-710 Application example Insulation monitoring device The medical IT system acc. to IEC 60364-7-710 consists of an isolating transformer, a monitoring device to monitor insulation resistance, transformer load and temperature and a remote alarm indicator and test combination, installed in the operating theatre, or at a manned nurse station, nearby. Continuous insulation monitoring ensures that a deterioration in insulation resistance is immediately detected and signalled but (this is the decisive factor) there is no power supply interruption and continuity of operation is guaranteed. The IT system transformer In accordance with IEC 61558-2-5, the rated output of the trans­former shall not be less than 0.5 kVA and shall not exceed 10 kVA. Single-phase transformers have to be used. If the supply of three-phase loads is also required, a separate three phase transformer shall be provided – secondary voltage must not exceed AC 250 V. The insulation monitoring device The insulation monitoring device isoMED427P is a vital unit to ensure the avail­ability of the IT system. Connected between system and earth, it con­tin­uously monitors the insulation resistance. The integrated AMP measuring principle allows insulation faults with DC components to be precisely recor­d­ed and indicated. Simultaneously, the ISOMETER® isoMED427P monitors the load current and the temperature of the transformer. Additionally it meets the requirements of IEC 61557-8. In addition, the isoMED427P includes a feature allowing insulation fault location, i.e. detecting online the faulty load (socket) in an intensive care unit or operating theatre in combination with the insulation fault locator EDS151. Alarm indicator and test combinations Isolating transformer Continuous insulation monitoring for immediate detection without power supply interruption.
  • 13. 13 Remote alarm indicator and operators MEDICS® – the safety solutions for medical locations according to IEC 60364-7-710 and DIN VDE 0100-710 (VDE 0100-710) MEDICS® – to ensure safe and reliable power supply MEDICS® is a comprehensive, tried and tested system that is able to realise each task on hand in order to secure the safe and reliable power supply for medical locations. Convincing benefits: n Monitoring and control of • Normal power supply (AV) • Safety power supply (SV) • Battery-supported safety power supply (e.g. UPS) in compliance with the standards n Designed in accordance with the requirements of applicable standards and monitoring of medical IT systems n Contains complete features of isoMED427P (Insulation monitoring device with integrated load and temperature monitoring and locating current injector) n User-oriented information for technical/medical person- nel with clear instructions to be followed n Comprehensive range of services throughout the entire life cycle of the system n Intelligent networking with information and communication technology – centrally on-site, decentrally with the SCADA system or monitored by the manufacturer n Additional safety advantage by ready-to-connect complete solutions with voluntary testing by TÜV Süddeutschland • Confirmation that the requirements of the standard DIN VDE 0100-710 (VDE 0100-710) are met • Certification of the functional safety (SIL2) in accordance with DIN EN 61508-... (VDE 0802-...) Typical applications: n Hospitals, clinics n Sanatoriums and health clinics n Residential homes for the elderly, nursing homes n Outpatient surgery in doctors' surgeries n Medical care centres Changeover for intensive care units with integrated insulation fault locator (EDS) Nurse desk Intensive care unit U1 U2 U3 I3 IL RISO T ATICS® -2-63A-ISO ϑ MK Distribution group 2 ATICS® -BP EDS151 BMS MK Second supply line Preferred supply line 2 2 2 2 2 2 COMTRAXX® MK800 Floor-standing cabinet Transfer switching and monitoring devices, 2-pole
  • 14. 14 Line Isolation Monitor (LIM) The safety solutions for medical locations according to ANSI/NFPA 99 and CSA Z32 LIM2010 Z, U THC COMTRAXX® MK800 MK800 EDS151 Convincing benefits: n No interference with electrical equipment n Special phase-locking circuitry for ultimate stability and repeatability n Provision for Remote Indicators n Easy to clean rugged front foil n Digital Analog Bar Graph Displays n Automatic self-calibration and self-check n Audible alarm volume adjustable via menu n Transformer Load Monitoring (optional) n Transformer overtemperature monitoring (optional) n RS-485/BMS communication port n Several LIMs can be controlled by one Remote n Additional communication devices available: Web server, eMail client n Insulation fault location system available (optional) Isolated Power System with Line Isolation Monitor for hospitals and other critical care areas. Isolated power systems offer an invaluable advantage: Early detection allows for critical systems to remain online in a single fault condition. Bender Isolated Power Panels provide isolated power to electrical systems in operating rooms and other critical care areas. Utilizing the latest in line isolation monitoring technology, the LIM2010 provides advanced warning of faults to help reduce downtime and increase operational efficiencies. The Bender LIM2010 Series LIM complies with UL 1022 in the U.S. and CSA-C22.2 No. 204-M1984 in Canada. The intent is to include the LIM as part of an isolated power system that conforms with the applicable requirements of ANSI/NFPA 99 and ANSI/NFPA 70 in the U.S. and in accordance with CAN/CSA-C22.2 No. 29-M1989 in Canada. IT system with load and temperature monitoring Bender isolated power system equipment are designed in strict compliance with UL 1047, UL 1022, UL 50 and CSA Z32. Isolated Power Panels
  • 15. 15 Safetytesterforservicepurposes UNIMET® test systems Test systems for the electrical safety of medical electrical devices and electrical equipment Electrical safety is a key concern when using medical electrical equipment and portable equipment. To protect users against any potential electrical hazards, there are various regulations and laws in place that make regular testing mandatory. With the UNIMET® safety testers initial verification at the manufacturer's plant; periodic testing and testing prior to first use and tests following maintenance and repairs can be carried out with ease. Standard compliant tests acc. to: n IEC 60601-1, 3rd edition (optional) n IEC 62353:2007-05 n DIN EN 62353 (VDE 0751-1):2008-08 n ÖVE/ÖNORM EN 62353:2009-01 n DIN VDE 0701-0702:2008-06 n ÖVE E8701-1:03-01 Testsystemforelectricbedsandelectrical equipmentacc.toBGVA3 Light-weight safety tester for mobile applications The user-friendly one amongst the safety testers for simple testing prior to first use, periodic testing, ... Convincing benefits: n Simple operation thanks to user guidance n Updating of test dates and multi-client capability n Time savings thanks to automated test procedures n Device under test classified in accordance with regulations n USB printer interface and TFT display, straightforward documentation via printer or PC
  • 16. 16 COMTRAXX® System components Central display, alarm indicator and operator units Signalling, operation, communication – Overview of your system Despite the increasing presence of technology in today's society – people retain a crucial role. These people need to be provided with the right information, in the right place and at the right time, so that they can take prompt and appropriate action. The Condition Monitor CP700 meets these central requirements. It is the central display, alarm indicator and Application example – BMS system integration PEM PEM CP700 I3 U1 U2 U3 M ATICS® Ethernet Web server System overviewVisualisation ProfiBus-DPDigital In/Out Digital In/Out Modbus RTU BMS bus ATICS-2-XXA-ISO ATICS-4-XXXA-DIO BMS bus BMS bus BMS bus KNX/LON ILTI3 U1 U2 U3 RISO M ATICS® BMS bus ext. BMS bus COM460IP COM460IP MK2430 MK800MK800 TM Modbus RTU E-Mail Report Parameter Modbus/TCP ... Solution for BACnet Solution for OPC COMTRAXX® MK800 COMTRAXX® MK800 Integrated functions Display, alarm indicator and operator unit – Web server, gateway and local display Access to all necessary information – always and everywhere via PC. operator unit from which various devices can be operated and parameterised in a uniform way, from the ISOMETER® through RCMS to Power Quality Monitoring – intuitive to use and supported by an interactive help system. This is possible through a built-in touchscreen and the integrated web server. In addition, the Condition Monitor CP700 and the gateway COM460IP serve as data providers for higher-level systems. Gateway with web server Communication solutions
  • 17. 17 A variety of solutions: n Use of existing IT infrastructure n Provision of messages and measured values for higher-level systems Convincing benefits: Overview of the entire system n Active alarm generation n Simple, direct access to all details relating to the devices in use n Guided support in fault analysis n Easy documentation of measured values and device parameters n User-definable visualisation n Displaying an overview the contents of which takes up more than one page n Active alarm generation n Access to information everywhere and at all times via PC n Integration of third-party devices n Viable for the future by improving and expanding the functionality by means of software updates Representation of device data on the touch screen (COMTRAXX® CP700)
  • 18. 18 Support at all stages All-round service for your installation: Remote, by phone, on-site Competent service for maximum safety and high availability of your installation ExpansionModernisatio n Planning Concept S electionofdevicesProjectscheduling Operatio n Maintenance Installation Com m issioning From planning to modernisation – Our know-how and our expertise is at your disposal in all project phases. Furthermore, our first-class service ensures you the maximum safety for your electrical installations. The service we offer range from telephone support through repairs to on-site service – with state-of-the-art measuring devices and professional employees. Many service activities, fault clearance, but also analysis and inspections, can be carried out by remote maintenance – no technician needs to be on-site, saving you time and money. Convincing benefits: n High availability of your installation by responding faster to fault messages n Automatic control, analysis, correction, readjustments/updates are possible n Competent assistance on changing settings and with updates n Regular checking of your installations/power quality/monitoring devices n Significant cost reduction by reduced downtimes and shorter service times Ex pan OperationMaintenance I nstallation
  • 19. 19 Bender worldwide Argentina Australia Austria Bahrain Bosnia and Herzegovina Brazil Bulgaria Canada Chile China Colombia Croatia Czech Republic Denmark Egypt Estonia Finland France Germany Great Britain Greece Hong Kong Hungary Iceland India Indonesia Iran Ireland Israel Italy Japan Jordan Kuwait Latvia Lebanon Lithuania Macedonia Malaysia Moldova Montenegro New Zealand Norway Pakistan Poland Portugal Qatar Romania Russia Saudi Arabia Serbia Singapore Slovakia Slovenia South Africa South Korea Spain Sri Lanka Sweden Switzerland Syria Tadzhikistan Taiwan Thailand The Netherlands The Philippines The United States of America Turkey United Arab Emirates Uruguay Venezuela Vietnam Yemen
  • 20. Bender GmbH Co. KG P.O. Box 1161 • 35301 Grünberg • Germany Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-Mail: info@bender.de • www.bender.de 2105en/03.2014/MSa/2500/JD-Druck/©BenderGmbHCo.KG,Germany–Subjecttochange!Thespecifiedstandardstakeintoaccounttheversionthatwasvalidatthetimeofprinting. Pictures: Fotolia (© Oleg Fedorenko), iStock (© beerkoff, © grybaz, © Teun van den Dries), Thinkstock (© Manfredini Mauro), Fraport AG and Bender archives. BENDER Group