Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs, from YAG to photocoagulators. The Merilas 810 shortpulse® laser provides glaucoma and retina treatments, and offers new laser therapy for advanced and end-stage glaucoma. Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and John Weiss & Son is pleased to be appointed as the Exclusive Distributor of the Merilas 810 in the UK.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs. From YAG to photocoagulators, the range includes the; MR Q & MR Q supine Nd:YAG lasers, Merilas 532nm & 577nm short pulse lasers, Merilas 532α green, Valon TT 532nm, Valon TT 577nm and the Valon 5G 532nm photocoagulator lasers. The range has the flexibility to couple some products to make complete systems.
Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and Haag-Streit UK is pleased to be appointed as the Exclusive Distributor of the Meridian YAG and photocoagulator laser range in the UK.
The compact Merilas 532α is a reliable and precise photocoagulator for use in all retinal photocoagulation procedures, iridotomy and laser trabeculoplasty. This professional frequency doubled solid state green laser photocoagulator can be used with a slit lamp adapter, ophthalmoscope or endo-probe.
The Merilas 577nm short pulse is a powerful yellow laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The Valon TT multispot laser provides the most intuitive and versatile controls available. A large resistive touch screen and the Smart Wheel controller, combined with unique information projection on the retina, puts you in complete control of the procedure.
The Merilas 532nm short pulse is a powerful green laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The MR Q is the new professional 1064nm laser for posterior capsulotomy, pupillary membranectomy and iridotomy. Featuring an anterior and posterior offset for optimal treatment, its ergonomic design allows full doctor and patient access.
The MR Q Supine is a fully-integrated ophthalmic laser for supine use, designed for capsulotomy and iridotomy. This is the only laser system on the market which allows the treatment of patients who are unable to sit at a slit lamp and is ideal for paediatric and elderly patients.
The Valon 5G photocoagulator is compact in size, easy to move and designed to fit the needs and budget of all kinds of clinics, while maintaining all Valon’s unique technical features. 5G includes all the features of previous models and can be fitted to a wide range of slit lamps, both existing and new. Additionally, the design allows the add on of laser indirect ophthalmoscopes and endoprobes.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs. From YAG to photocoagulators, the range includes the; MR Q & MR Q supine Nd:YAG lasers, Merilas 532nm & 577nm short pulse lasers, Merilas 532α green, Valon TT 532nm, Valon TT 577nm and the Valon 5G 532nm photocoagulator lasers. The range has the flexibility to couple some products to make complete systems.
Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and Haag-Streit UK is pleased to be appointed as the Exclusive Distributor of the Meridian YAG and photocoagulator laser range in the UK.
The compact Merilas 532α is a reliable and precise photocoagulator for use in all retinal photocoagulation procedures, iridotomy and laser trabeculoplasty. This professional frequency doubled solid state green laser photocoagulator can be used with a slit lamp adapter, ophthalmoscope or endo-probe.
The Merilas 577nm short pulse is a powerful yellow laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The Valon TT multispot laser provides the most intuitive and versatile controls available. A large resistive touch screen and the Smart Wheel controller, combined with unique information projection on the retina, puts you in complete control of the procedure.
The Merilas 532nm short pulse is a powerful green laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The MR Q is the new professional 1064nm laser for posterior capsulotomy, pupillary membranectomy and iridotomy. Featuring an anterior and posterior offset for optimal treatment, its ergonomic design allows full doctor and patient access.
The MR Q Supine is a fully-integrated ophthalmic laser for supine use, designed for capsulotomy and iridotomy. This is the only laser system on the market which allows the treatment of patients who are unable to sit at a slit lamp and is ideal for paediatric and elderly patients.
The Valon 5G photocoagulator is compact in size, easy to move and designed to fit the needs and budget of all kinds of clinics, while maintaining all Valon’s unique technical features. 5G includes all the features of previous models and can be fitted to a wide range of slit lamps, both existing and new. Additionally, the design allows the add on of laser indirect ophthalmoscopes and endoprobes.
Meridian's Merilas 810 shortpulse laser provides glaucoma and retina treatments and offers new laser therapy for advanced and end-stage glaucoma. The laser boasts outstanding usability, and features a rapid start-up time. The detachable touch-screen display features an easy-to-use, intuitive design, ensuring full flexibility for the user.
The Valon TT offers a safe, efficient PRP treatment in six minutes or less. Its galvanometric scanners, providing the most advanced technology available, deliver patterns of shots faster than a single spot with conventional lasers.
Valon’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, thus reducing treatment risks and improving patient comfort and safety.
LASERSMART™ Laboratories: A Safety Primer WhitepaperJustin Clough
A narrative checklist of considerations when setting up a laser laboratory. While not a complete list, the goal is to guide you away from the most common pitfalls.
NEWCON OPTIK - Night Vision, Laser Range Finders, Thermal, Stabilized Imagers, Binoculars, Goggles, Monoculars, Night Vision Scopes by Newcon Optik
Newcon Optik didirikan dengan tujuan untuk memproduksi dan memasok pasar dengan sistem optik state-of-the-art, yang berbasis di Kanada, R & D dan manufaktur dan distribusi di seluruh dunia. Dengan kemampuan manufaktur dan R & D, standar tertinggi dari kualitas dan kepuasan pelanggan menjadi jaminan. Harga kompetitif dan faktor kunci sukses lainnya telah membuat Newcon Optik diterima di pasar internasional.
Merek dagang Newcon Optik 's diakui di seluruh dunia dan perusahaan serta diakui sebagai nama merek terkemuka di semua sektor utama dan pasar di tingkat global, termasuk dalam berbagai militer, penegakan hukum, pencarian dan penyelamatan, pengawasan, berburu, berkemah, dan sektor profesional kelautan di seluruh penjuru dunia. Jaringan dealer Newcon Optik mencakup 5 benua. Sampai dengan 90% dari produk Newcon Optik mendukung profesional di 60 negara.
Asal Negara : Kanada
Jenis Industri : Binocular , Tactical Equipment
Kategori Produk : Night Vision Equipment , Laser Rangefinders , Image Stabilizers , Image Intensifier Tubes , Tactical Optics , Thermal Imagers , Aimers & Illuminators , Binoculars & Lenses
Hingga kini Tridinamika dipercaya sebagai pen- jual / authorized distributor newcon optik di Indonesia. Dapatkan spesifikasi, review untuk referensi pembelian binocular dari newcon optik
untuk informasi hubungi
Tridinamika Test and Measurement
sales@tridinamika.com
021 5467618
Laser Safety Eyewear Product Catalog by Kentek CorporationJustin Clough
Kentek Corporation is respected worldwide as an important source for all laser safety products and services. Kentek offers custom and stock products.
Understanding your laser protective eyewear needs, at Kentek, we know that no two faces are alike, so we can help make your eyewear choice as easy as possible by offering the widest selection of frames and filters.
The comprehensive range of Reyrolle products provides the total protection requirements of distribution markets and industrial applications – ranging from overcurrent protection via transformer protection and voltage control to a full spectrum of auxiliary and trip relays.
Contact us for any Enquiry of the above product on: +91-9819614841, +91-9833686249
Know more at: https://www.dsgenterprises.in/siemens/reyrolle
The Indian Dental Academy is the Leader in continuing dental education , training dentists in all aspects of dentistry and
offering a wide range of dental certified courses in different formats.for more details please visit
www.indiandentalacademy.com
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
The Haag-Streit UK 2024 Price List contains Haag-Streit UK’s key products. Please find enclosed information and pricing for our best-selling range, including everything from a small budgie stick, to the World-leading Tonosafe disposable prisms, to gold standard Haag-Streit slit lamps.
Meridian's Merilas 810 shortpulse laser provides glaucoma and retina treatments and offers new laser therapy for advanced and end-stage glaucoma. The laser boasts outstanding usability, and features a rapid start-up time. The detachable touch-screen display features an easy-to-use, intuitive design, ensuring full flexibility for the user.
The Valon TT offers a safe, efficient PRP treatment in six minutes or less. Its galvanometric scanners, providing the most advanced technology available, deliver patterns of shots faster than a single spot with conventional lasers.
Valon’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, thus reducing treatment risks and improving patient comfort and safety.
LASERSMART™ Laboratories: A Safety Primer WhitepaperJustin Clough
A narrative checklist of considerations when setting up a laser laboratory. While not a complete list, the goal is to guide you away from the most common pitfalls.
NEWCON OPTIK - Night Vision, Laser Range Finders, Thermal, Stabilized Imagers, Binoculars, Goggles, Monoculars, Night Vision Scopes by Newcon Optik
Newcon Optik didirikan dengan tujuan untuk memproduksi dan memasok pasar dengan sistem optik state-of-the-art, yang berbasis di Kanada, R & D dan manufaktur dan distribusi di seluruh dunia. Dengan kemampuan manufaktur dan R & D, standar tertinggi dari kualitas dan kepuasan pelanggan menjadi jaminan. Harga kompetitif dan faktor kunci sukses lainnya telah membuat Newcon Optik diterima di pasar internasional.
Merek dagang Newcon Optik 's diakui di seluruh dunia dan perusahaan serta diakui sebagai nama merek terkemuka di semua sektor utama dan pasar di tingkat global, termasuk dalam berbagai militer, penegakan hukum, pencarian dan penyelamatan, pengawasan, berburu, berkemah, dan sektor profesional kelautan di seluruh penjuru dunia. Jaringan dealer Newcon Optik mencakup 5 benua. Sampai dengan 90% dari produk Newcon Optik mendukung profesional di 60 negara.
Asal Negara : Kanada
Jenis Industri : Binocular , Tactical Equipment
Kategori Produk : Night Vision Equipment , Laser Rangefinders , Image Stabilizers , Image Intensifier Tubes , Tactical Optics , Thermal Imagers , Aimers & Illuminators , Binoculars & Lenses
Hingga kini Tridinamika dipercaya sebagai pen- jual / authorized distributor newcon optik di Indonesia. Dapatkan spesifikasi, review untuk referensi pembelian binocular dari newcon optik
untuk informasi hubungi
Tridinamika Test and Measurement
sales@tridinamika.com
021 5467618
Laser Safety Eyewear Product Catalog by Kentek CorporationJustin Clough
Kentek Corporation is respected worldwide as an important source for all laser safety products and services. Kentek offers custom and stock products.
Understanding your laser protective eyewear needs, at Kentek, we know that no two faces are alike, so we can help make your eyewear choice as easy as possible by offering the widest selection of frames and filters.
The comprehensive range of Reyrolle products provides the total protection requirements of distribution markets and industrial applications – ranging from overcurrent protection via transformer protection and voltage control to a full spectrum of auxiliary and trip relays.
Contact us for any Enquiry of the above product on: +91-9819614841, +91-9833686249
Know more at: https://www.dsgenterprises.in/siemens/reyrolle
The Indian Dental Academy is the Leader in continuing dental education , training dentists in all aspects of dentistry and
offering a wide range of dental certified courses in different formats.for more details please visit
www.indiandentalacademy.com
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
The Haag-Streit UK 2024 Price List contains Haag-Streit UK’s key products. Please find enclosed information and pricing for our best-selling range, including everything from a small budgie stick, to the World-leading Tonosafe disposable prisms, to gold standard Haag-Streit slit lamps.
Our slit lamps are famous, not only for providing excellent optics and high precision mechanics, but also for their exceptional durability. The longevity resulting from high quality Swiss manufacturing makes these slit lamps one of the best investments one can ever make for its practice.
This guide is intended to assist those who seek to capture images of the
eye, using the slit lamp, to improve the quality of their photography by using
simple-to-follow illumination diagrams and high quality image examples.
We hope this book provides inspiration and motivation to anyone who is
involved in the art of documenting the unique properties and pathologies of
the eye and through Haag-Streit we offer a number of instruments to help
you.
Haag-Streit offers two anterior segment cameras: the Imaging Module 910 as the best-in-class device which provides unbeatable image quality, and the Imaging Module 600 which is a cost-efficient alternative.
In this edition of 'InFocus' we reflect on the success of our attendance at 100% Ophthalmology earlier this year, where we sponsored the Ophthalmology Hub, providing three innovative educational lectures and also ran our popular Eyesi Slit Lamp simulator competition. As the official Haag-Streit distributor for Northern Ireland, we look ahead to travelling to Belfast for the RCOphth Annual Congress 2024.
The Eyesi Indirect Opthalmoscope ROP Simulator (Eyesi Indirect ROP) is a
mixed reality simulator for training of retinal examinations on preterm infants using a binocular indirect ophthalmoscope. The simulator comes with a didactically structured curriculum designed for teaching device handling and classification of retinopathy of prematurity (ROP).
The correct care of microsurgical instruments not only reduces costs by extending instrument life, it also impacts on surgical outcomes and a reduction in complications. Special attention should be paid to the handling, storage, cleaning and sterilisation of instruments.
The John Weiss range of gold-standard precision ophthalmic micro-surgical instruments has been engineered to meet the individual demands of the specialist Surgeon. Its range of precision instruments are available to view in an easy-to-use online catalogue.
Haag-Streit UK is proud to be the Sole UK Distributor of the range - John Weiss is the leading brand of micro-surgical instruments domestically, and is currently exported to over 40 countries worldwide.
Enhance your older Haag-Streit slit lamps by converting them to use a 14mm LED illumination system. Many eye clinics are still using tungsten bulbs in slit lamps, which can lead to equipment down-time when the bulb needs to be replaced. Frequent bulb changes in busy clinics can be costly.
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
Keep up-to-date with the latest news from Haag-Streit UK by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
MedOne Surgical develops, manufactures and distributes high-quality specialty surgical products World-wide, with a focus on single-use products for vitreoretinal surgery.
KERARING intrastromal corneal ring segments are the most complete and versatile corneal remodelling system in the World. The precision implantable devices correct corneal surface irregularities and reduce refractive errors associated with keratoconus and other corneal ectatic disorders.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Rasamanikya is a excellent preparation in the field of Rasashastra, it is used in various Kushtha Roga, Shwasa, Vicharchika, Bhagandara, Vatarakta, and Phiranga Roga. In this article Preparation& Comparative analytical profile for both Formulationon i.e Rasamanikya prepared by Kushmanda swarasa & Churnodhaka Shodita Haratala. The study aims to provide insights into the comparative efficacy and analytical aspects of these formulations for enhanced therapeutic outcomes.
Adv. biopharm. APPLICATION OF PHARMACOKINETICS : TARGETED DRUG DELIVERY SYSTEMSAkankshaAshtankar
MIP 201T & MPH 202T
ADVANCED BIOPHARMACEUTICS & PHARMACOKINETICS : UNIT 5
APPLICATION OF PHARMACOKINETICS : TARGETED DRUG DELIVERY SYSTEMS By - AKANKSHA ASHTANKAR
NVBDCP.pptx Nation vector borne disease control programSapna Thakur
NVBDCP was launched in 2003-2004 . Vector-Borne Disease: Disease that results from an infection transmitted to humans and other animals by blood-feeding arthropods, such as mosquitoes, ticks, and fleas. Examples of vector-borne diseases include Dengue fever, West Nile Virus, Lyme disease, and malaria.
ABDOMINAL TRAUMA in pediatrics part one.drhasanrajab
Abdominal trauma in pediatrics refers to injuries or damage to the abdominal organs in children. It can occur due to various causes such as falls, motor vehicle accidents, sports-related injuries, and physical abuse. Children are more vulnerable to abdominal trauma due to their unique anatomical and physiological characteristics. Signs and symptoms include abdominal pain, tenderness, distension, vomiting, and signs of shock. Diagnosis involves physical examination, imaging studies, and laboratory tests. Management depends on the severity and may involve conservative treatment or surgical intervention. Prevention is crucial in reducing the incidence of abdominal trauma in children.
Ozempic: Preoperative Management of Patients on GLP-1 Receptor Agonists Saeid Safari
Preoperative Management of Patients on GLP-1 Receptor Agonists like Ozempic and Semiglutide
ASA GUIDELINE
NYSORA Guideline
2 Case Reports of Gastric Ultrasound
Basavarajeeyam is an important text for ayurvedic physician belonging to andhra pradehs. It is a popular compendium in various parts of our country as well as in andhra pradesh. The content of the text was presented in sanskrit and telugu language (Bilingual). One of the most famous book in ayurvedic pharmaceutics and therapeutics. This book contains 25 chapters called as prakaranas. Many rasaoushadis were explained, pioneer of dhatu druti, nadi pareeksha, mutra pareeksha etc. Belongs to the period of 15-16 century. New diseases like upadamsha, phiranga rogas are explained.
Knee anatomy and clinical tests 2024.pdfvimalpl1234
This includes all relevant anatomy and clinical tests compiled from standard textbooks, Campbell,netter etc..It is comprehensive and best suited for orthopaedicians and orthopaedic residents.
- Video recording of this lecture in English language: https://youtu.be/kqbnxVAZs-0
- Video recording of this lecture in Arabic language: https://youtu.be/SINlygW1Mpc
- Link to download the book free: https://nephrotube.blogspot.com/p/nephrotube-nephrology-books.html
- Link to NephroTube website: www.NephroTube.com
- Link to NephroTube social media accounts: https://nephrotube.blogspot.com/p/join-nephrotube-on-social-media.html
263778731218 Abortion Clinic /Pills In Harare ,sisternakatoto
263778731218 Abortion Clinic /Pills In Harare ,ABORTION WOMEN’S CLINIC +27730423979 IN women clinic we believe that every woman should be able to make choices in her pregnancy. Our job is to provide compassionate care, safety,affordable and confidential services. That’s why we have won the trust from all generations of women all over the world. we use non surgical method(Abortion pills) to terminate…Dr.LISA +27730423979women Clinic is committed to providing the highest quality of obstetrical and gynecological care to women of all ages. Our dedicated staff aim to treat each patient and her health concerns with compassion and respect.Our dedicated group ABORTION WOMEN’S CLINIC +27730423979 IN women clinic we believe that every woman should be able to make choices in her pregnancy. Our job is to provide compassionate care, safety,affordable and confidential services. That’s why we have won the trust from all generations of women all over the world. we use non surgical method(Abortion pills) to terminate…Dr.LISA +27730423979women Clinic is committed to providing the highest quality of obstetrical and gynecological care to women of all ages. Our dedicated staff aim to treat each patient and her health concerns with compassion and respect.Our dedicated group of receptionists, nurses, and physicians have worked together as a teamof receptionists, nurses, and physicians have worked together as a team wwww.lisywomensclinic.co.za/
These simplified slides by Dr. Sidra Arshad present an overview of the non-respiratory functions of the respiratory tract.
Learning objectives:
1. Enlist the non-respiratory functions of the respiratory tract
2. Briefly explain how these functions are carried out
3. Discuss the significance of dead space
4. Differentiate between minute ventilation and alveolar ventilation
5. Describe the cough and sneeze reflexes
Study Resources:
1. Chapter 39, Guyton and Hall Textbook of Medical Physiology, 14th edition
2. Chapter 34, Ganong’s Review of Medical Physiology, 26th edition
3. Chapter 17, Human Physiology by Lauralee Sherwood, 9th edition
4. Non-respiratory functions of the lungs https://academic.oup.com/bjaed/article/13/3/98/278874
2. your laser specialist
2 of 14
INDEX
Foreword 3
Laser Excellence 3
Single spot – laser photocoagulators
for Retina and Glaucoma treatment 4
Merilas 532 α –
single spot photocoagulator 5
Merilas 532 shortpulse –
single spot photocoagulator 5
Merilas 577 shortpulse –
single spot photocoagulator 6
Merilas 810 shortpulse –
single spot photocoagulator 6
Multispot laser photocoagulator –
for Retina treatment 7
5G 8
TT 532 8
TT 577 9
Nd:YAG lasers – for Posterior Capsulotomy,
Pupillary Membranectomy and Iridotomy 10
MR Q 11
MR Q Supine 12
MR Q SLT (coming soon) 13
3. your laser specialist
3 of 14
FOREWORD
Laser Excellence
Meridian AG was founded in 1937, and our history is closely linked to the genesis of medical
Nd:YAG lasers. The association with Prof. Dr. Franz Fankhauser help in the development of
the first commercial Nd:YAG laser for ophthalmology back in 1982: The Microruptor II.
Later in 1994 Meridian AG launched our first Argon laser, the Merilite, in 2006, the first
Merilas laser. Later on, as new technologies arise, our in-house engineers developed Short-
Pulse.
In memory of Prof. Dr. Franz Fankhauser,
the pioneer of the first commercial Nd:YAG
laser in ophthalmology and president of the
board of directors of Meridian.
Today Meridian continues expanding its portfolio through proprietary innovations and ac-
quisitions. Meridian selects and integrates the best Swiss and European laser and optical
components with three manufacturing facilities across Europe, ensuring the highest quality
and long-term reliability.
Meridian products following these principles:
■
■ Superior quality and longevity
■
■ Usability
■
■ Safety
■
■ Flexibility and control
Our highly skilled and experienced staff thrives on delivering the best product service. Our
manufacturing standards, best engineering and product integration practices ensure ulti-
mate performance in every system sold. It assures the results our customers expect, always
maintaining the safety of the patients as our priority.
4. your laser specialist
4 of 14
SINGLE SPOT – LASER PHOTOCOAGULATORS
FOR RETINA AND GLAUCOMA TREATMENT
Superior Quality & Longevity
Meridian lasers are built using a robust aluminium housing, providing protection to the internal components. Our
cavities are cooled by a proprietary thermoelectric cooling system, eliminating the need for fans and noises, with
the advantage of maintaining the laser output stable and a dust-free system.
Usability
The Merilas lasers feature a fast start – up, allowing immediate access when required. The detachable user inter-
face display has an intuitive design, and its glass technology ensures flexibility and cleanliness at the workplace.
The Merilas lasers are fully featured photocoagulators, on a small, compact foot print, and a portable presentation.
Safety
Merilas features separate menu modes to identify continuous wave and short pulse modes quickly
■
■ Double confirmation when switching between laser modes
■
■ Parafocal laser design – gentle on cornea –
Flexibility & Comfort
Our range of slit lamp delivery systems is compatible with a wide range of slit lamp styles, either Haag-Streit or
Zeiss.
■
■ Merilas offers a combo system with Meridian Medical MR Q Nd:YAG. This combination saves space.
■
■ Alternatively, the Merilas family is compatible with Laser Indirect Ophthalmoscopy and endo-probes.
Accessories:
■
■ Microscope filters for Haag-Streit, Zeiss, Leica, Topcon (passive and active)
■
■ External USB fan, recommended when the laser is operating in rooms over 28 degrees Celsius
0633
5. your laser specialist
5 of 14
Single spot photocoagulator
Award-winning and fully-featured frequency-doubled solid-state
green laser photocoagulator. A compact and practical unit de-
signed for the general ophthalmologist.
Accessories
■
■ Original BQ Haag Streit delivery adapters, fitted by factory
trained engineers
■
■ Universal Slit Lamp Adapters with seamless coupling with almost
any Zeiss or Haag-Streit style SL
Clinical Indication
■
■ General Retinal Photocoagulation Procedures
■
■ Iridotomy in PACG
■
■ Laser Trabeculoplasty (ALT) in PAOG
Single spot photocoagulator
The Merilas 532 nm is an ophthalmic laser photocoagulator featur-
ing shortpulse, with dual treatment modality: subthreshold or con-
tinuous wave. They are designed for efficiency, safety and reliability.
■
■ The shortpulse technology delivers a tissue-sparing solution that
allows the tissue to cool between laser pulses, preventing tissue
damage, reducing treatment risks, and improving patient comfort
and safety
■
■ A versatile array of treatments
■
■ Higher patient comfort due to its lower energy settings
Clinical Indication
■
■ Subthreshold Treatment
■
■ General Retinal Photocoagulation Procedures
■
■ Iridotomy in Angle-closure Glaucoma
■
■ Soft Laser Trabeculoplasty (ALT) with Shortpulse
6. your laser specialist
6 of 14
Single spot photocoagulator
The Merilas 577 nm is an ophthalmic laser photocoagulator featur-
ing shortpulse, with dual treatment modality: subthreshold or con-
tinuous wave. They are designed for efficiency, safety and reliability.
■
■ As the 577 nm is not absorbed by the Xanthophyll, it is the ideal
laser wavelength for safer treatment around macula and foveal
areas
■
■ The shortpulse technology delivers a tissue-sparing solution that
allows the tissue to cool between laser pulses, preventing tissue
damage, reducing treatment risks, improving patient comfort and
safety due its lower energy settings
Clinical Indication
■
■ Gently Macular Subthreshold Treatment
■
■ All Retinal Photocoagulator Procedures
■
■ Iridotomy in Angle-closure Glaucoma
■
■ Softer Laser Trabeculoplasty (ALT)
Single spot photocoagulator
The 810 nm wavelength is less absorbed by melanin and haemo-
globin. This wavelength has the advantage of penetrating the sclera
and excessive haemorrhage, making it ideal for treating the ciliary
body, undeveloped newborn retinas and retinal tumour ablations.
Clinical Indication
■
■ Diabetic Retinopathy
■
■ Central Serous Chorioretinopathy
■
■ Diabetic Macular Edema
■
■ Central/Branch Retinal Vein Occlusion
■
■ Retinal Tears, Holes and Detachments
■
■ Retinopathy of the Premature (ROP)
■
■ Retinoblastoma Ablation
Glaucoma and Retina
■
■ Transscleral Cyclophotocoagulation
7. your laser specialist
7 of 14
MULTISPOT LASER PHOTOCOAGULATOR –
FOR RETINA TREATMENT
Superior Quality & Longevity
To meet the strict quality requirements for our products, we exclusively use proprietary cavities designed and
manufactured in our Meridian Medical facilities. The Merilas laser housing made of robust and resistant material
keeps the unit’s interior protected and, in a dust-free environment.
Usability
The multispot range features live retinal projection for visibility of laser settings, laser power values, pattern selec-
tion, size and rotation without removing the eyes from the binoculars.
■
■ With intuitive laser control through the smart-wheel or touch screen, the TT and 5G provide a fast overview of
settings and pattern selection
■
■ Meridian’s proprietary smart wheel controller makes the laser operation fast and easy. It allows adjusting most
parameters such as laser power, pattern size and rotation
■
■ The advanced features of the laser may help to reduce treatment time and increases patient satisfaction
Safety
To ensure safe and painless treatment, we have implemented various safety features in the system:
■
■ Restricted pattern size
■
■ Fluence calculation combined with spot size control
■
■ Time limit in any pattern less than 0.7 seconds
■
■ Outline projection of patterns to ensure the visibility of both tissues to be treated and spot intensity immediately
after delivery
■
■ Restricted total time of pattern delivery
Furthermore, the display shows different automatic reminders built in the system to ensure safe treatment. The
height adjustment of the table is blocked when the laser is in “Ready mode”.
Flexibility & Comfort
An appropriate choice of a slit lamp (Haag-Streit BM/BQ, Keeler Symphony or CSO SL 9900) is installed and cali-
brated by our factory-trained service engineers. Specialised designed adapters ensure excellent laser delivery and
retina illumination without the need for calibration.
0537
8. your laser specialist
8 of 14
The 5G photocoagulator is designed to work with the existing slit
lamps of the clinic. A fully-featured laser delivers maximum laser
quality while allowing mobility and connectivity with different laser
delivery accessories.
Easy to use, versatile and mobile.
■
■ Upgradeable to use with LIO and endo-probes
■
■ Compatible with a wide range of slit lamps
The TT 532 is a multispot laser featuring a functional and modern
design with all peripheral components integrated into the table.
The smart-wheel and retinal projection of the set values control
make the workflow easy and efficient.
■
■ Excellent laser delivery
■
■ Industry fastest pattern with 1ms between spots
■
■ Appropriate safety features
■
■ Laser console, electronics and computer integrated into a func-
tional and straightforward design
■
■ Factory integration with Haag-Streit BQ and CSO (HS style) slit
lamps
■
■ Good accessibility for wheelchairs and patient chairs
9. your laser specialist
9 of 14
The TT 577 is a multispot shortpulse laser featuring a functional
and modern design with all peripheral components integrated into
the table.
The smart-wheel and retinal projection of the set values control
make the workflow straightforward and efficient.
The shortpulse technology delivers a tissue-sparing solution that
allows the tissue to cool between laser pulses, preventing tissue
damage, reducing treatment risks, improving patient comfort and
safety.
As the 577 nm is not absorbed by the Xanthophyll, it is the ideal la-
ser wavelength for safer treatment around macula and foveal areas
■
■ Ideal setting for retinal specialist, combining the best of Swiss
optics with the ideal laser wavelength
■
■ Factory integration with Haag-Streit BQ and CSO (HS style) slit
lamps
■
■ Industry fastest pattern with 1 ms between spots
■
■ Appropriate safety features
10. your laser specialist
10 of 14
ND:YAG LASERS – FOR POSTERIOR CAPSULOTOMY,
PUPILLARY MEMBRANECTOMY AND IRIDOTOMY
Superior Quality & Longevity
Meridian Nd:YAG lasers are fully-featured units, integrated on state-of-the-art slit lamps with LED illumination, five-
fold magnification changer (6×, 10×, 16×, 25× & 40×) and premium precision optics.
The MR Q family is modularly built, and its proprietary laser cavities are tested under stressed conditions, not
showing a decline in laser-quality over 600’000 shots.
The laser housing is made of aluminium monobloc, giving a solid feeling when operating the laser head.
Usability
The laser fast start-up time allows immediate use. The control panel is built-in on the body of the laser for easy
access. Users can choose between anterior and posterior off-set to optimise the treatments.
Ergonomic bilateral laser controls allow easy access to the parameters changing.
Safety
■
■ After each use, the laser automatically resets to its default parameters
■
■ Electronic offset controller, the safest offset in any laser
■
■ MR Q features an industry standard two-point red aiming beam focusing system
Flexibility & Comfort
■
■ Remote service capabilities and calibration combo options with Merilas
■
■ Remote service capabilities
■
■ Combo options with Merilas
1304
11. your laser specialist
11 of 14
Meridian MR Q is a fully integrated YAG laser combined with a
renowned precision optics LED slit lamp with fivefold magnification
changer (6×, 10×, 16×, 25× & 40×).
Clinical Indication
■
■ Posterior Capsulotomy
■
■ Pupillary Membranectomy
■
■ Iridotomy
Meridian offers tables with one or two motorised columns. Both
settings ensure an ergonomic sitting position with wheelchair
accessibility. For small practice rooms, the MR Q is available as a
space-saving standalone unit.
12. your laser specialist
12 of 14
The only Nd:YAG designed for the
operating room
This unique system enables the treatment of paediatric patients
or those unable to sit at a slit lamp. The supine position provides
the ideal setup for the operating room for patients and staff. In the
consulting room, the MR Q Supine offers a relaxed environment
spa-like to treat your patient, providing the surgeon with a more
ergonomic position and making handling contact lenses and eye
drops easier.
The MR Q supine allows the treatment of children, the elderly, dis-
abled, anaesthetised patients, and anyone who cannot sit behind a
slit lamp for a longer time.
Efficient and smooth workflow:
■
■ Specially designed for operation theatres
■
■ Ergonomic 0-210° inclinable Haag-Streit Surgical binoculars
allow comfortable operation
■
■ 4-digit protected PIN code authenticates doctor to use MR Q
Supine
Clinical Indication
■
■ Posterior Capsulotomy
■
■ Pupillary Membranectomy
■
■ Iridotomy
13. your laser specialist
13 of 14
Latest technology Nd:YAG & SLT laser
Meridian Medical MR Q SLT is a fully integrated Nd:YAG & SLT laser
combined with a renowned precision optics LED slit lamp with a
magnification range from 6 × up to 40 × selectable in 5 fixed steps.
The V-split tower allows coaxial Nd:YAG treatments. This tower pro-
duces a red reflex that results in retro illumination of the posterior
capsule optimising capsulotomy with a higher degree of safety.
■
■ Ergonomic handles of the chin rest
■
■ Integrated tonometer pin
■
■ Easy to use 7” touch display
■
■ Two-point focusing system
Clinical Indication
■
■ Posterior Capsulotomy
■
■ Pupillary Membranectomy
■
■ Iridotomy
■
■ Selective Laser Trabeculoplasty
■
■ YAG treatments with coaxial illumination
Tips for your laser
■
■ Ongoing preventive maintenance service assures optimal performance of the laser and can early detect laser
cavity degradation
■
■ If your electricity grid is unstable, always use a surge protector
■
■ Read the user manual and don’t use the laser beyond its intended use and without its capabilities
(coming soon)