The MR Q is the new professional 1064nm laser for posterior capsulotomy, pupillary membranectomy and iridotomy. Featuring an anterior and posterior offset for optimal treatment, its ergonomic design allows full doctor and patient access.
The MR Q Supine is a fully-integrated ophthalmic laser for supine use, designed for capsulotomy and iridotomy. This is the only laser system on the market which allows the treatment of patients who are unable to sit at a slit lamp and is ideal for paediatric and elderly patients.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs. From YAG to photocoagulators, the range includes the; MR Q & MR Q supine Nd:YAG lasers, Merilas 532nm & 577nm short pulse lasers, Merilas 532α green, Valon TT 532nm, Valon TT 577nm and the Valon 5G 532nm photocoagulator lasers. The range has the flexibility to couple some products to make complete systems.
Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and Haag-Streit UK is pleased to be appointed as the Exclusive Distributor of the Meridian YAG and photocoagulator laser range in the UK.
The Merilas 577nm short pulse is a powerful yellow laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The compact Merilas 532α is a reliable and precise photocoagulator for use in all retinal photocoagulation procedures, iridotomy and laser trabeculoplasty. This professional frequency doubled solid state green laser photocoagulator can be used with a slit lamp adapter, ophthalmoscope or endo-probe.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs, from YAG to photocoagulators. The Merilas 810 shortpulse® laser provides glaucoma and retina treatments, and offers new laser therapy for advanced and end-stage glaucoma. Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and John Weiss & Son is pleased to be appointed as the Exclusive Distributor of the Merilas 810 in the UK.
The Merilas 532nm short pulse is a powerful green laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The Valon 5G photocoagulator is compact in size, easy to move and designed to fit the needs and budget of all kinds of clinics, while maintaining all Valon’s unique technical features. 5G includes all the features of previous models and can be fitted to a wide range of slit lamps, both existing and new. Additionally, the design allows the add on of laser indirect ophthalmoscopes and endoprobes.
The MR Q Supine is a fully-integrated ophthalmic laser for supine use, designed for capsulotomy and iridotomy. This is the only laser system on the market which allows the treatment of patients who are unable to sit at a slit lamp and is ideal for paediatric and elderly patients.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs. From YAG to photocoagulators, the range includes the; MR Q & MR Q supine Nd:YAG lasers, Merilas 532nm & 577nm short pulse lasers, Merilas 532α green, Valon TT 532nm, Valon TT 577nm and the Valon 5G 532nm photocoagulator lasers. The range has the flexibility to couple some products to make complete systems.
Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and Haag-Streit UK is pleased to be appointed as the Exclusive Distributor of the Meridian YAG and photocoagulator laser range in the UK.
The Merilas 577nm short pulse is a powerful yellow laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The compact Merilas 532α is a reliable and precise photocoagulator for use in all retinal photocoagulation procedures, iridotomy and laser trabeculoplasty. This professional frequency doubled solid state green laser photocoagulator can be used with a slit lamp adapter, ophthalmoscope or endo-probe.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs, from YAG to photocoagulators. The Merilas 810 shortpulse® laser provides glaucoma and retina treatments, and offers new laser therapy for advanced and end-stage glaucoma. Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and John Weiss & Son is pleased to be appointed as the Exclusive Distributor of the Merilas 810 in the UK.
The Merilas 532nm short pulse is a powerful green laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The Valon 5G photocoagulator is compact in size, easy to move and designed to fit the needs and budget of all kinds of clinics, while maintaining all Valon’s unique technical features. 5G includes all the features of previous models and can be fitted to a wide range of slit lamps, both existing and new. Additionally, the design allows the add on of laser indirect ophthalmoscopes and endoprobes.
Meridian's Merilas 810 shortpulse laser provides glaucoma and retina treatments and offers new laser therapy for advanced and end-stage glaucoma. The laser boasts outstanding usability, and features a rapid start-up time. The detachable touch-screen display features an easy-to-use, intuitive design, ensuring full flexibility for the user.
The Valon TT multispot laser provides the most intuitive and versatile controls available. A large resistive touch screen and the Smart Wheel controller, combined with unique information projection on the retina, puts you in complete control of the procedure.
The Valon TT offers a safe, efficient PRP treatment in six minutes or less. Its galvanometric scanners, providing the most advanced technology available, deliver patterns of shots faster than a single spot with conventional lasers.
Valon’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, thus reducing treatment risks and improving patient comfort and safety.
JERICHO OPHTHALMIC MULTISPOT GREEN LASER SYSTEM-532NMGovindarajanR5
Appa Ophthalmic Multispot Green Laser Jericho is designed with effective touch screen interface providing superior surgical treatment to retinal problems.
Laser HF Hagen Wergen 0918158933 Vat lieu nha khoa chinh hang gia sivatlieunhakhoa
Máy phẩu thuật cắt đốt cầm máu và trị liệu nha khoa đa năng bằng công nghệ Laser và cao tần F đến từ Đức 0918158933. Vat lieu nha khoa chinh hang gia si
*Tính năng:
-Thiết kế I-Cube với bàn phím điều khiển bằng màn hình cảm ứng 2 trong 1: Kết hợp công nghệ cắt đốt, giải phẩu, và nhiều phương pháp trị liệu khác bằng tia Laser tiên tiến và công nghệ cắt đốt cầm máu cao tần HF.
- Tùy chọn trang bị thêm tay kẹp tự khâu vết thương hở, không cần chỉ khâu.
- Làm lành, giảm đau vết thương bằng công nghệ điều trị bệnh lý bằng tia Laser Năng Lượng Thấp LLLT.
- Điều trị nha khoa bằng liệu pháp Quang Động Lực PDT bằng tia Laser.
- Với khả năng tùy chọn trang bị thêm tay Laser tẩy trắng răng bằng tia Laser với thuốc tẩy trắng răng MiraWhite từ chính hãng Hager Werken, Đức.
-Tay cắt đốt cao tần với mọi tính năng tiên tiến như: cắt đốt, cầm máu.
- Phẫu thuật tạo hình nướu.
- Diệt khuẩn tăng cường ống tủy bằng tia Laser sau khi ống túy đã được lấy và rửa sạch bằng dung dịch sát khuẩn.
https://www.facebook.com/386115188817133
A rugged, cost-effective, ultra-compact micro laser measuring at just .5” x 3.5” and weighing just 40 grams. The MicroJewel is a 1064 diode pumped laser with Q-switched, high peak power pulses and excellent shot-shot stability. Even with its compact design, it still delivers up to 8mJ of energy and up to a 5Hz rep rate.
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
The Haag-Streit UK 2024 Price List contains Haag-Streit UK’s key products. Please find enclosed information and pricing for our best-selling range, including everything from a small budgie stick, to the World-leading Tonosafe disposable prisms, to gold standard Haag-Streit slit lamps.
Meridian's Merilas 810 shortpulse laser provides glaucoma and retina treatments and offers new laser therapy for advanced and end-stage glaucoma. The laser boasts outstanding usability, and features a rapid start-up time. The detachable touch-screen display features an easy-to-use, intuitive design, ensuring full flexibility for the user.
The Valon TT multispot laser provides the most intuitive and versatile controls available. A large resistive touch screen and the Smart Wheel controller, combined with unique information projection on the retina, puts you in complete control of the procedure.
The Valon TT offers a safe, efficient PRP treatment in six minutes or less. Its galvanometric scanners, providing the most advanced technology available, deliver patterns of shots faster than a single spot with conventional lasers.
Valon’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, thus reducing treatment risks and improving patient comfort and safety.
JERICHO OPHTHALMIC MULTISPOT GREEN LASER SYSTEM-532NMGovindarajanR5
Appa Ophthalmic Multispot Green Laser Jericho is designed with effective touch screen interface providing superior surgical treatment to retinal problems.
Laser HF Hagen Wergen 0918158933 Vat lieu nha khoa chinh hang gia sivatlieunhakhoa
Máy phẩu thuật cắt đốt cầm máu và trị liệu nha khoa đa năng bằng công nghệ Laser và cao tần F đến từ Đức 0918158933. Vat lieu nha khoa chinh hang gia si
*Tính năng:
-Thiết kế I-Cube với bàn phím điều khiển bằng màn hình cảm ứng 2 trong 1: Kết hợp công nghệ cắt đốt, giải phẩu, và nhiều phương pháp trị liệu khác bằng tia Laser tiên tiến và công nghệ cắt đốt cầm máu cao tần HF.
- Tùy chọn trang bị thêm tay kẹp tự khâu vết thương hở, không cần chỉ khâu.
- Làm lành, giảm đau vết thương bằng công nghệ điều trị bệnh lý bằng tia Laser Năng Lượng Thấp LLLT.
- Điều trị nha khoa bằng liệu pháp Quang Động Lực PDT bằng tia Laser.
- Với khả năng tùy chọn trang bị thêm tay Laser tẩy trắng răng bằng tia Laser với thuốc tẩy trắng răng MiraWhite từ chính hãng Hager Werken, Đức.
-Tay cắt đốt cao tần với mọi tính năng tiên tiến như: cắt đốt, cầm máu.
- Phẫu thuật tạo hình nướu.
- Diệt khuẩn tăng cường ống tủy bằng tia Laser sau khi ống túy đã được lấy và rửa sạch bằng dung dịch sát khuẩn.
https://www.facebook.com/386115188817133
A rugged, cost-effective, ultra-compact micro laser measuring at just .5” x 3.5” and weighing just 40 grams. The MicroJewel is a 1064 diode pumped laser with Q-switched, high peak power pulses and excellent shot-shot stability. Even with its compact design, it still delivers up to 8mJ of energy and up to a 5Hz rep rate.
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
The Haag-Streit UK 2024 Price List contains Haag-Streit UK’s key products. Please find enclosed information and pricing for our best-selling range, including everything from a small budgie stick, to the World-leading Tonosafe disposable prisms, to gold standard Haag-Streit slit lamps.
Our slit lamps are famous, not only for providing excellent optics and high precision mechanics, but also for their exceptional durability. The longevity resulting from high quality Swiss manufacturing makes these slit lamps one of the best investments one can ever make for its practice.
This guide is intended to assist those who seek to capture images of the
eye, using the slit lamp, to improve the quality of their photography by using
simple-to-follow illumination diagrams and high quality image examples.
We hope this book provides inspiration and motivation to anyone who is
involved in the art of documenting the unique properties and pathologies of
the eye and through Haag-Streit we offer a number of instruments to help
you.
Haag-Streit offers two anterior segment cameras: the Imaging Module 910 as the best-in-class device which provides unbeatable image quality, and the Imaging Module 600 which is a cost-efficient alternative.
In this edition of 'InFocus' we reflect on the success of our attendance at 100% Ophthalmology earlier this year, where we sponsored the Ophthalmology Hub, providing three innovative educational lectures and also ran our popular Eyesi Slit Lamp simulator competition. As the official Haag-Streit distributor for Northern Ireland, we look ahead to travelling to Belfast for the RCOphth Annual Congress 2024.
The Eyesi Indirect Opthalmoscope ROP Simulator (Eyesi Indirect ROP) is a
mixed reality simulator for training of retinal examinations on preterm infants using a binocular indirect ophthalmoscope. The simulator comes with a didactically structured curriculum designed for teaching device handling and classification of retinopathy of prematurity (ROP).
The correct care of microsurgical instruments not only reduces costs by extending instrument life, it also impacts on surgical outcomes and a reduction in complications. Special attention should be paid to the handling, storage, cleaning and sterilisation of instruments.
The John Weiss range of gold-standard precision ophthalmic micro-surgical instruments has been engineered to meet the individual demands of the specialist Surgeon. Its range of precision instruments are available to view in an easy-to-use online catalogue.
Haag-Streit UK is proud to be the Sole UK Distributor of the range - John Weiss is the leading brand of micro-surgical instruments domestically, and is currently exported to over 40 countries worldwide.
Enhance your older Haag-Streit slit lamps by converting them to use a 14mm LED illumination system. Many eye clinics are still using tungsten bulbs in slit lamps, which can lead to equipment down-time when the bulb needs to be replaced. Frequent bulb changes in busy clinics can be costly.
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
Keep up-to-date with the latest news from Haag-Streit UK by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
MedOne Surgical develops, manufactures and distributes high-quality specialty surgical products World-wide, with a focus on single-use products for vitreoretinal surgery.
KERARING intrastromal corneal ring segments are the most complete and versatile corneal remodelling system in the World. The precision implantable devices correct corneal surface irregularities and reduce refractive errors associated with keratoconus and other corneal ectatic disorders.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Report Back from SGO 2024: What’s the Latest in Cervical Cancer?bkling
Are you curious about what’s new in cervical cancer research or unsure what the findings mean? Join Dr. Emily Ko, a gynecologic oncologist at Penn Medicine, to learn about the latest updates from the Society of Gynecologic Oncology (SGO) 2024 Annual Meeting on Women’s Cancer. Dr. Ko will discuss what the research presented at the conference means for you and answer your questions about the new developments.
New Directions in Targeted Therapeutic Approaches for Older Adults With Mantl...i3 Health
i3 Health is pleased to make the speaker slides from this activity available for use as a non-accredited self-study or teaching resource.
This slide deck presented by Dr. Kami Maddocks, Professor-Clinical in the Division of Hematology and
Associate Division Director for Ambulatory Operations
The Ohio State University Comprehensive Cancer Center, will provide insight into new directions in targeted therapeutic approaches for older adults with mantle cell lymphoma.
STATEMENT OF NEED
Mantle cell lymphoma (MCL) is a rare, aggressive B-cell non-Hodgkin lymphoma (NHL) accounting for 5% to 7% of all lymphomas. Its prognosis ranges from indolent disease that does not require treatment for years to very aggressive disease, which is associated with poor survival (Silkenstedt et al, 2021). Typically, MCL is diagnosed at advanced stage and in older patients who cannot tolerate intensive therapy (NCCN, 2022). Although recent advances have slightly increased remission rates, recurrence and relapse remain very common, leading to a median overall survival between 3 and 6 years (LLS, 2021). Though there are several effective options, progress is still needed towards establishing an accepted frontline approach for MCL (Castellino et al, 2022). Treatment selection and management of MCL are complicated by the heterogeneity of prognosis, advanced age and comorbidities of patients, and lack of an established standard approach for treatment, making it vital that clinicians be familiar with the latest research and advances in this area. In this activity chaired by Michael Wang, MD, Professor in the Department of Lymphoma & Myeloma at MD Anderson Cancer Center, expert faculty will discuss prognostic factors informing treatment, the promising results of recent trials in new therapeutic approaches, and the implications of treatment resistance in therapeutic selection for MCL.
Target Audience
Hematology/oncology fellows, attending faculty, and other health care professionals involved in the treatment of patients with mantle cell lymphoma (MCL).
Learning Objectives
1.) Identify clinical and biological prognostic factors that can guide treatment decision making for older adults with MCL
2.) Evaluate emerging data on targeted therapeutic approaches for treatment-naive and relapsed/refractory MCL and their applicability to older adults
3.) Assess mechanisms of resistance to targeted therapies for MCL and their implications for treatment selection
Pulmonary Thromboembolism - etilogy, types, medical- Surgical and nursing man...VarunMahajani
Disruption of blood supply to lung alveoli due to blockage of one or more pulmonary blood vessels is called as Pulmonary thromboembolism. In this presentation we will discuss its causes, types and its management in depth.
Tom Selleck Health: A Comprehensive Look at the Iconic Actor’s Wellness Journeygreendigital
Tom Selleck, an enduring figure in Hollywood. has captivated audiences for decades with his rugged charm, iconic moustache. and memorable roles in television and film. From his breakout role as Thomas Magnum in Magnum P.I. to his current portrayal of Frank Reagan in Blue Bloods. Selleck's career has spanned over 50 years. But beyond his professional achievements. fans have often been curious about Tom Selleck Health. especially as he has aged in the public eye.
Follow us on: Pinterest
Introduction
Many have been interested in Tom Selleck health. not only because of his enduring presence on screen but also because of the challenges. and lifestyle choices he has faced and made over the years. This article delves into the various aspects of Tom Selleck health. exploring his fitness regimen, diet, mental health. and the challenges he has encountered as he ages. We'll look at how he maintains his well-being. the health issues he has faced, and his approach to ageing .
Early Life and Career
Childhood and Athletic Beginnings
Tom Selleck was born on January 29, 1945, in Detroit, Michigan, and grew up in Sherman Oaks, California. From an early age, he was involved in sports, particularly basketball. which played a significant role in his physical development. His athletic pursuits continued into college. where he attended the University of Southern California (USC) on a basketball scholarship. This early involvement in sports laid a strong foundation for his physical health and disciplined lifestyle.
Transition to Acting
Selleck's transition from an athlete to an actor came with its physical demands. His first significant role in "Magnum P.I." required him to perform various stunts and maintain a fit appearance. This role, which he played from 1980 to 1988. necessitated a rigorous fitness routine to meet the show's demands. setting the stage for his long-term commitment to health and wellness.
Fitness Regimen
Workout Routine
Tom Selleck health and fitness regimen has evolved. adapting to his changing roles and age. During his "Magnum, P.I." days. Selleck's workouts were intense and focused on building and maintaining muscle mass. His routine included weightlifting, cardiovascular exercises. and specific training for the stunts he performed on the show.
Selleck adjusted his fitness routine as he aged to suit his body's needs. Today, his workouts focus on maintaining flexibility, strength, and cardiovascular health. He incorporates low-impact exercises such as swimming, walking, and light weightlifting. This balanced approach helps him stay fit without putting undue strain on his joints and muscles.
Importance of Flexibility and Mobility
In recent years, Selleck has emphasized the importance of flexibility and mobility in his fitness regimen. Understanding the natural decline in muscle mass and joint flexibility with age. he includes stretching and yoga in his routine. These practices help prevent injuries, improve posture, and maintain mobilit
Acute scrotum is a general term referring to an emergency condition affecting the contents or the wall of the scrotum.
There are a number of conditions that present acutely, predominantly with pain and/or swelling
A careful and detailed history and examination, and in some cases, investigations allow differentiation between these diagnoses. A prompt diagnosis is essential as the patient may require urgent surgical intervention
Testicular torsion refers to twisting of the spermatic cord, causing ischaemia of the testicle.
Testicular torsion results from inadequate fixation of the testis to the tunica vaginalis producing ischemia from reduced arterial inflow and venous outflow obstruction.
The prevalence of testicular torsion in adult patients hospitalized with acute scrotal pain is approximately 25 to 50 percent
These simplified slides by Dr. Sidra Arshad present an overview of the non-respiratory functions of the respiratory tract.
Learning objectives:
1. Enlist the non-respiratory functions of the respiratory tract
2. Briefly explain how these functions are carried out
3. Discuss the significance of dead space
4. Differentiate between minute ventilation and alveolar ventilation
5. Describe the cough and sneeze reflexes
Study Resources:
1. Chapter 39, Guyton and Hall Textbook of Medical Physiology, 14th edition
2. Chapter 34, Ganong’s Review of Medical Physiology, 26th edition
3. Chapter 17, Human Physiology by Lauralee Sherwood, 9th edition
4. Non-respiratory functions of the lungs https://academic.oup.com/bjaed/article/13/3/98/278874
Recomendações da OMS sobre cuidados maternos e neonatais para uma experiência pós-natal positiva.
Em consonância com os ODS – Objetivos do Desenvolvimento Sustentável e a Estratégia Global para a Saúde das Mulheres, Crianças e Adolescentes, e aplicando uma abordagem baseada nos direitos humanos, os esforços de cuidados pós-natais devem expandir-se para além da cobertura e da simples sobrevivência, de modo a incluir cuidados de qualidade.
Estas diretrizes visam melhorar a qualidade dos cuidados pós-natais essenciais e de rotina prestados às mulheres e aos recém-nascidos, com o objetivo final de melhorar a saúde e o bem-estar materno e neonatal.
Uma “experiência pós-natal positiva” é um resultado importante para todas as mulheres que dão à luz e para os seus recém-nascidos, estabelecendo as bases para a melhoria da saúde e do bem-estar a curto e longo prazo. Uma experiência pós-natal positiva é definida como aquela em que as mulheres, pessoas que gestam, os recém-nascidos, os casais, os pais, os cuidadores e as famílias recebem informação consistente, garantia e apoio de profissionais de saúde motivados; e onde um sistema de saúde flexível e com recursos reconheça as necessidades das mulheres e dos bebês e respeite o seu contexto cultural.
Estas diretrizes consolidadas apresentam algumas recomendações novas e já bem fundamentadas sobre cuidados pós-natais de rotina para mulheres e neonatos que recebem cuidados no pós-parto em unidades de saúde ou na comunidade, independentemente dos recursos disponíveis.
É fornecido um conjunto abrangente de recomendações para cuidados durante o período puerperal, com ênfase nos cuidados essenciais que todas as mulheres e recém-nascidos devem receber, e com a devida atenção à qualidade dos cuidados; isto é, a entrega e a experiência do cuidado recebido. Estas diretrizes atualizam e ampliam as recomendações da OMS de 2014 sobre cuidados pós-natais da mãe e do recém-nascido e complementam as atuais diretrizes da OMS sobre a gestão de complicações pós-natais.
O estabelecimento da amamentação e o manejo das principais intercorrências é contemplada.
Recomendamos muito.
Vamos discutir essas recomendações no nosso curso de pós-graduação em Aleitamento no Instituto Ciclos.
Esta publicação só está disponível em inglês até o momento.
Prof. Marcus Renato de Carvalho
www.agostodourado.com
Prix Galien International 2024 Forum ProgramLevi Shapiro
June 20, 2024, Prix Galien International and Jerusalem Ethics Forum in ROME. Detailed agenda including panels:
- ADVANCES IN CARDIOLOGY: A NEW PARADIGM IS COMING
- WOMEN’S HEALTH: FERTILITY PRESERVATION
- WHAT’S NEW IN THE TREATMENT OF INFECTIOUS,
ONCOLOGICAL AND INFLAMMATORY SKIN DISEASES?
- ARTIFICIAL INTELLIGENCE AND ETHICS
- GENE THERAPY
- BEYOND BORDERS: GLOBAL INITIATIVES FOR DEMOCRATIZING LIFE SCIENCE TECHNOLOGIES AND PROMOTING ACCESS TO HEALTHCARE
- ETHICAL CHALLENGES IN LIFE SCIENCES
- Prix Galien International Awards Ceremony
Explore natural remedies for syphilis treatment in Singapore. Discover alternative therapies, herbal remedies, and lifestyle changes that may complement conventional treatments. Learn about holistic approaches to managing syphilis symptoms and supporting overall health.
HOT NEW PRODUCT! BIG SALES FAST SHIPPING NOW FROM CHINA!! EU KU DB BK substit...GL Anaacs
Contact us if you are interested:
Email / Skype : kefaya1771@gmail.com
Threema: PXHY5PDH
New BATCH Ku !!! MUCH IN DEMAND FAST SALE EVERY BATCH HAPPY GOOD EFFECT BIG BATCH !
Contact me on Threema or skype to start big business!!
Hot-sale products:
NEW HOT EUTYLONE WHITE CRYSTAL!!
5cl-adba precursor (semi finished )
5cl-adba raw materials
ADBB precursor (semi finished )
ADBB raw materials
APVP powder
5fadb/4f-adb
Jwh018 / Jwh210
Eutylone crystal
Protonitazene (hydrochloride) CAS: 119276-01-6
Flubrotizolam CAS: 57801-95-3
Metonitazene CAS: 14680-51-4
Payment terms: Western Union,MoneyGram,Bitcoin or USDT.
Deliver Time: Usually 7-15days
Shipping method: FedEx, TNT, DHL,UPS etc.Our deliveries are 100% safe, fast, reliable and discreet.
Samples will be sent for your evaluation!If you are interested in, please contact me, let's talk details.
We specializes in exporting high quality Research chemical, medical intermediate, Pharmaceutical chemicals and so on. Products are exported to USA, Canada, France, Korea, Japan,Russia, Southeast Asia and other countries.
2. your laser specialist
2 of 12
BEYOND A HISTORICAL NAME
Following the Microruptor’s legacy, Meridian Medical’s MR Q has been
redesigned and replaces the MR6.
3. your laser specialist
3 of 12
SUPERIOR QUALITY & LONGEVITY
Meridian Medical MR Q is a fully-featured and integrated Nd:YAG laser combined
with renowned European precision optics. The high-grade aluminum mono-block
laser housing gives a unique solid feeling.
The MR Q features a super gaussian mode laser profile. Its performance and accu-
racy provide excellent laser treatments. The MR Q internal power meters monitor the
energy delivered to enhance patient safety.
The LED slit lamp offers five steps magnification changer, from 6 × to 40 ×.
The MR Q’s laser cavities are tested under severe conditions, demonstrating out-
standing performance of over 600’000 shots.
4. your laser specialist
4 of 12
USABILITY
The MR Q is a fully-featured and powerful Nd:YAG in a compact design.
The MR Q provides unique safety features at every start with digitally controlled
anterior and posterior offset.
The laser knobs are ergonomically placed on both sides of the slit lamp. The slit
lamp quality allows the use of MR Q as a diagnostic device.
5. your laser specialist
5 of 12
SAFETY
After every treatment, the electronically controlled offset resets to posterior 100 μm,
eliminating the risk of inadvertently firing with the wrong offset.
Meridian Medical service team can remotely access the MR Q, adding a unique ser-
vice delivery method with immediate support.(*)
(*) world time zone may affect the availability of our technicians
6. your laser specialist
6 of 12
FLEXIBILITY & COMFORT
MR Q is ideal for any practice size. The laser can be installed on an existing
height-adjustable evaluation stand as a space-saving stand-alone unit. Meridian
Medical offers two motorized tables: a wheelchair-friendly, two-column table pre-
senting excellent ergonomics for patients and doctors and a single column for small
areas.
The ergonomic positioning of the handles on the chinrest guarantees a comfortable
sitting position for the patient, thus increasing the patient comfort.
The MR Q couples with the Merilas 532α, 532SP and 577SP lasers, offering a versa-
tile unit for Nd:YAG and photocoagulation treatments.
7. your laser specialist
7 of 12
LASER EXCELLENCE
The history of Meridian AG, now showing up as Meridian Medical
Group, and the history of the medical Nd:YAG laser are closely
connected. The Microruptor II, developed by Meridian engineers
and Prof. Dr. Franz Fankhauser († 2020), changed the way of many
ophthalmology treatments.
New technology is continuously developed and patented by our
development engineers. We select and integrate the best Swiss and
European laser components to ensure the highest quality and long-
term reliability.
TIPS FOR YOUR LASER
■ Yearly maintenance service assures the optimal performance of
your laser
■ Follow the safety advice of the manufacturer and your regulatory
body
■ Only use the laser as described in the IFU
CLINICAL INDICATION
For posterior capsulotomy and iridotomy.
8. your laser specialist
8 of 12
STANDARD ACCESSORIES
■ Laser safety sign
■ Safety goggles
■ Dust cover
OPTIONAL ACCESSORIES
■ Foot-switch
■ Single port beam splitter
■ Co-observation tube
■ Adapter for ½” digital camera
9. your laser specialist
9 of 12
ND:YAG TREATMENT GUIDELINES*
These guidelines have been prepared following industry standards Nd:YAG treatments, the use
of the laser and its parameters are responsibility of the treating ophthalmologist.
Procedure Power (mJ) Offset Pulses
Posterior Capsulotomy (with lens) 0.9 – 2.0 Posterior 200 Single
Posterior Capsulotomy (w/o lens) 1.4 – 2.5 Posterior 200 Single
Anterior Capsulotomy 0.5 – 1.0 0 Single
Peripheral Iridotomy 3.0 – 5.0 Posterior 100 Double-Triple
Peripheral Iridotomy (plateau iris) 5.0 – 7.0 Posterior 200 Triple
Vitreous Strands (anterior) 2.0 – 3.00 Posterior 100 Single
IOL Surface Cleaning 0.3 Anterior 100 Single
* Suggested parameters for the Nd:YAG treatment from Lindstrom, R. (1986) Review of the clinial literature of the use of the Nd:YAG laser for posterior cap-
sulotomy. JCRS Vol 12. March, 1986
10. your laser specialist
10 of 12
BINOCULARS IN FOCUS
Each user must have the oculars set for their personal refraction, this way the laser will be in par-
focality with the aiming beam and retina. Defocused slit lamp may result in unpredictable laser
burns.
ABOUT THE OFFSET
Laser energy travels towards the point of emission (to the front of the eye), when shooting on ze-
ro-offset the risk of lens pitting increases. Always check the offset before perform any treatment.
11. your laser specialist
11 of 12
TECHNICAL SPECIFICATIONS*
Device description MR Q |
Laser source Q-switched, solid state Nd:YAG 1064 nm
Pulse duration 4 ns
Pulse setting 1,2 or 3 pulses
Maximum repetition rate up to 2.5 Hz
Maximum energy 32 mJ
Treatment spot size 10 μm
Cone angle 16°
Treatment beam offset range Electronically controlled offset,
anterior: 150 μm, 300 μm;
posterior: 0 μm, 100 μm, 200 μm, 300 μm;
Aiming beam Red Diode; 635 nm (dual)
Magnification (6 ×; 10 ×; 16 ×; 25 ×; 40 ×)
Cooling system Air cooled
Weight 24 kg / 53 lbs. (Unpacked)
Power rating 100 – 240 VAC, 50 / 60 Hz
Power requirements 100 VA
* All technical specifications are subject to change without notice. In accordance with the international laser safety standards: IEC 60601-1:2005 + A1:2012,
EN 60601-1-2:2015, MDD 93/42/EEC.
600 mm / 24“
660
mm
/
26“
455 mm / 17.9“
440 mm / 17.5“
390 mm / 15.3“
1304