The MR Q Supine is a fully-integrated ophthalmic laser for supine use, designed for capsulotomy and iridotomy. This is the only laser system on the market which allows the treatment of patients who are unable to sit at a slit lamp and is ideal for paediatric and elderly patients.
The MR Q is the new professional 1064nm laser for posterior capsulotomy, pupillary membranectomy and iridotomy. Featuring an anterior and posterior offset for optimal treatment, its ergonomic design allows full doctor and patient access.
The Valon TT offers a safe, efficient PRP treatment in six minutes or less. Its galvanometric scanners, providing the most advanced technology available, deliver patterns of shots faster than a single spot with conventional lasers.
Valon’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, thus reducing treatment risks and improving patient comfort and safety.
The Valon 5G photocoagulator is compact in size, easy to move and designed to fit the needs and budget of all kinds of clinics, while maintaining all Valon’s unique technical features. 5G includes all the features of previous models and can be fitted to a wide range of slit lamps, both existing and new. Additionally, the design allows the add on of laser indirect ophthalmoscopes and endoprobes.
The Merilas 577nm short pulse is a powerful yellow laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The compact Merilas 532α is a reliable and precise photocoagulator for use in all retinal photocoagulation procedures, iridotomy and laser trabeculoplasty. This professional frequency doubled solid state green laser photocoagulator can be used with a slit lamp adapter, ophthalmoscope or endo-probe.
The Merilas 532nm short pulse is a powerful green laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
Meridian's Merilas 810 shortpulse laser provides glaucoma and retina treatments and offers new laser therapy for advanced and end-stage glaucoma. The laser boasts outstanding usability, and features a rapid start-up time. The detachable touch-screen display features an easy-to-use, intuitive design, ensuring full flexibility for the user.
The MR Q Supine is a fully-integrated ophthalmic laser for supine use, designed for capsulotomy and iridotomy. This is the only laser system on the market which allows the treatment of patients who are unable to sit at a slit lamp and is ideal for paediatric and elderly patients.
The MR Q is the new professional 1064nm laser for posterior capsulotomy, pupillary membranectomy and iridotomy. Featuring an anterior and posterior offset for optimal treatment, its ergonomic design allows full doctor and patient access.
The Valon TT offers a safe, efficient PRP treatment in six minutes or less. Its galvanometric scanners, providing the most advanced technology available, deliver patterns of shots faster than a single spot with conventional lasers.
Valon’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, thus reducing treatment risks and improving patient comfort and safety.
The Valon 5G photocoagulator is compact in size, easy to move and designed to fit the needs and budget of all kinds of clinics, while maintaining all Valon’s unique technical features. 5G includes all the features of previous models and can be fitted to a wide range of slit lamps, both existing and new. Additionally, the design allows the add on of laser indirect ophthalmoscopes and endoprobes.
The Merilas 577nm short pulse is a powerful yellow laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
The compact Merilas 532α is a reliable and precise photocoagulator for use in all retinal photocoagulation procedures, iridotomy and laser trabeculoplasty. This professional frequency doubled solid state green laser photocoagulator can be used with a slit lamp adapter, ophthalmoscope or endo-probe.
The Merilas 532nm short pulse is a powerful green laser system designed to treat retinal disorders. Meridian’s short pulse technology delivers a tissue-sparing solution that allows the tissue to cool between laser pulses. This minimises or prevents tissue damage, reducing treatment risks. Patient comfort and safety is improved as no tissue damages or scars occur.
Meridian's Merilas 810 shortpulse laser provides glaucoma and retina treatments and offers new laser therapy for advanced and end-stage glaucoma. The laser boasts outstanding usability, and features a rapid start-up time. The detachable touch-screen display features an easy-to-use, intuitive design, ensuring full flexibility for the user.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs. From YAG to photocoagulators, the range includes the; MR Q & MR Q supine Nd:YAG lasers, Merilas 532nm & 577nm short pulse lasers, Merilas 532α green, Valon TT 532nm, Valon TT 577nm and the Valon 5G 532nm photocoagulator lasers. The range has the flexibility to couple some products to make complete systems.
Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and Haag-Streit UK is pleased to be appointed as the Exclusive Distributor of the Meridian YAG and photocoagulator laser range in the UK.
The Valon TT multispot laser provides the most intuitive and versatile controls available. A large resistive touch screen and the Smart Wheel controller, combined with unique information projection on the retina, puts you in complete control of the procedure.
Laser HF Hagen Wergen 0918158933 Vat lieu nha khoa chinh hang gia sivatlieunhakhoa
Máy phẩu thuật cắt đốt cầm máu và trị liệu nha khoa đa năng bằng công nghệ Laser và cao tần F đến từ Đức 0918158933. Vat lieu nha khoa chinh hang gia si
*Tính năng:
-Thiết kế I-Cube với bàn phím điều khiển bằng màn hình cảm ứng 2 trong 1: Kết hợp công nghệ cắt đốt, giải phẩu, và nhiều phương pháp trị liệu khác bằng tia Laser tiên tiến và công nghệ cắt đốt cầm máu cao tần HF.
- Tùy chọn trang bị thêm tay kẹp tự khâu vết thương hở, không cần chỉ khâu.
- Làm lành, giảm đau vết thương bằng công nghệ điều trị bệnh lý bằng tia Laser Năng Lượng Thấp LLLT.
- Điều trị nha khoa bằng liệu pháp Quang Động Lực PDT bằng tia Laser.
- Với khả năng tùy chọn trang bị thêm tay Laser tẩy trắng răng bằng tia Laser với thuốc tẩy trắng răng MiraWhite từ chính hãng Hager Werken, Đức.
-Tay cắt đốt cao tần với mọi tính năng tiên tiến như: cắt đốt, cầm máu.
- Phẫu thuật tạo hình nướu.
- Diệt khuẩn tăng cường ống tủy bằng tia Laser sau khi ống túy đã được lấy và rửa sạch bằng dung dịch sát khuẩn.
https://www.facebook.com/386115188817133
International Journal of Computational Engineering Research(IJCER)ijceronline
International Journal of Computational Engineering Research(IJCER) is an intentional online Journal in English monthly publishing journal. This Journal publish original research work that contributes significantly to further the scientific knowledge in engineering and Technology.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs, from YAG to photocoagulators. The Merilas 810 shortpulse® laser provides glaucoma and retina treatments, and offers new laser therapy for advanced and end-stage glaucoma. Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and John Weiss & Son is pleased to be appointed as the Exclusive Distributor of the Merilas 810 in the UK.
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
The Haag-Streit UK 2024 Price List contains Haag-Streit UK’s key products. Please find enclosed information and pricing for our best-selling range, including everything from a small budgie stick, to the World-leading Tonosafe disposable prisms, to gold standard Haag-Streit slit lamps.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs. From YAG to photocoagulators, the range includes the; MR Q & MR Q supine Nd:YAG lasers, Merilas 532nm & 577nm short pulse lasers, Merilas 532α green, Valon TT 532nm, Valon TT 577nm and the Valon 5G 532nm photocoagulator lasers. The range has the flexibility to couple some products to make complete systems.
Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and Haag-Streit UK is pleased to be appointed as the Exclusive Distributor of the Meridian YAG and photocoagulator laser range in the UK.
The Valon TT multispot laser provides the most intuitive and versatile controls available. A large resistive touch screen and the Smart Wheel controller, combined with unique information projection on the retina, puts you in complete control of the procedure.
Laser HF Hagen Wergen 0918158933 Vat lieu nha khoa chinh hang gia sivatlieunhakhoa
Máy phẩu thuật cắt đốt cầm máu và trị liệu nha khoa đa năng bằng công nghệ Laser và cao tần F đến từ Đức 0918158933. Vat lieu nha khoa chinh hang gia si
*Tính năng:
-Thiết kế I-Cube với bàn phím điều khiển bằng màn hình cảm ứng 2 trong 1: Kết hợp công nghệ cắt đốt, giải phẩu, và nhiều phương pháp trị liệu khác bằng tia Laser tiên tiến và công nghệ cắt đốt cầm máu cao tần HF.
- Tùy chọn trang bị thêm tay kẹp tự khâu vết thương hở, không cần chỉ khâu.
- Làm lành, giảm đau vết thương bằng công nghệ điều trị bệnh lý bằng tia Laser Năng Lượng Thấp LLLT.
- Điều trị nha khoa bằng liệu pháp Quang Động Lực PDT bằng tia Laser.
- Với khả năng tùy chọn trang bị thêm tay Laser tẩy trắng răng bằng tia Laser với thuốc tẩy trắng răng MiraWhite từ chính hãng Hager Werken, Đức.
-Tay cắt đốt cao tần với mọi tính năng tiên tiến như: cắt đốt, cầm máu.
- Phẫu thuật tạo hình nướu.
- Diệt khuẩn tăng cường ống tủy bằng tia Laser sau khi ống túy đã được lấy và rửa sạch bằng dung dịch sát khuẩn.
https://www.facebook.com/386115188817133
International Journal of Computational Engineering Research(IJCER)ijceronline
International Journal of Computational Engineering Research(IJCER) is an intentional online Journal in English monthly publishing journal. This Journal publish original research work that contributes significantly to further the scientific knowledge in engineering and Technology.
Meridian offers a comprehensive portfolio of lasers, designed to meet every Surgeon's needs, from YAG to photocoagulators. The Merilas 810 shortpulse® laser provides glaucoma and retina treatments, and offers new laser therapy for advanced and end-stage glaucoma. Meridian has been developing, manufacturing and maintaining ophthalmic lasers for more than 35 years and John Weiss & Son is pleased to be appointed as the Exclusive Distributor of the Merilas 810 in the UK.
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
The Haag-Streit UK 2024 Price List contains Haag-Streit UK’s key products. Please find enclosed information and pricing for our best-selling range, including everything from a small budgie stick, to the World-leading Tonosafe disposable prisms, to gold standard Haag-Streit slit lamps.
Our slit lamps are famous, not only for providing excellent optics and high precision mechanics, but also for their exceptional durability. The longevity resulting from high quality Swiss manufacturing makes these slit lamps one of the best investments one can ever make for its practice.
This guide is intended to assist those who seek to capture images of the
eye, using the slit lamp, to improve the quality of their photography by using
simple-to-follow illumination diagrams and high quality image examples.
We hope this book provides inspiration and motivation to anyone who is
involved in the art of documenting the unique properties and pathologies of
the eye and through Haag-Streit we offer a number of instruments to help
you.
Haag-Streit offers two anterior segment cameras: the Imaging Module 910 as the best-in-class device which provides unbeatable image quality, and the Imaging Module 600 which is a cost-efficient alternative.
In this edition of 'InFocus' we reflect on the success of our attendance at 100% Ophthalmology earlier this year, where we sponsored the Ophthalmology Hub, providing three innovative educational lectures and also ran our popular Eyesi Slit Lamp simulator competition. As the official Haag-Streit distributor for Northern Ireland, we look ahead to travelling to Belfast for the RCOphth Annual Congress 2024.
The Eyesi Indirect Opthalmoscope ROP Simulator (Eyesi Indirect ROP) is a
mixed reality simulator for training of retinal examinations on preterm infants using a binocular indirect ophthalmoscope. The simulator comes with a didactically structured curriculum designed for teaching device handling and classification of retinopathy of prematurity (ROP).
The correct care of microsurgical instruments not only reduces costs by extending instrument life, it also impacts on surgical outcomes and a reduction in complications. Special attention should be paid to the handling, storage, cleaning and sterilisation of instruments.
The John Weiss range of gold-standard precision ophthalmic micro-surgical instruments has been engineered to meet the individual demands of the specialist Surgeon. Its range of precision instruments are available to view in an easy-to-use online catalogue.
Haag-Streit UK is proud to be the Sole UK Distributor of the range - John Weiss is the leading brand of micro-surgical instruments domestically, and is currently exported to over 40 countries worldwide.
Enhance your older Haag-Streit slit lamps by converting them to use a 14mm LED illumination system. Many eye clinics are still using tungsten bulbs in slit lamps, which can lead to equipment down-time when the bulb needs to be replaced. Frequent bulb changes in busy clinics can be costly.
Haag-Streit UK designs, manufactures and sells a complete line of optometry and ophthalmic equipment and has distributorships for some leading brands, such as; Haag-Streit Diagnostics, Haag-Streit Simulation, Meridian and Optovue. The 2024 Catalogue contains some of the key products within the HS-UK portfolio.
Keep up-to-date with the latest news from Haag-Streit UK by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
MedOne Surgical develops, manufactures and distributes high-quality specialty surgical products World-wide, with a focus on single-use products for vitreoretinal surgery.
KERARING intrastromal corneal ring segments are the most complete and versatile corneal remodelling system in the World. The precision implantable devices correct corneal surface irregularities and reduce refractive errors associated with keratoconus and other corneal ectatic disorders.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK and John Weiss by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Keep up-to-date with the latest news from Haag-Streit UK by checking out our latest 'In Focus' newsletter. The newsletter contains all the most recent updates from both organisations, from product launches to events to special offers.
Ozempic: Preoperative Management of Patients on GLP-1 Receptor Agonists Saeid Safari
Preoperative Management of Patients on GLP-1 Receptor Agonists like Ozempic and Semiglutide
ASA GUIDELINE
NYSORA Guideline
2 Case Reports of Gastric Ultrasound
Flu Vaccine Alert in Bangalore Karnatakaaddon Scans
As flu season approaches, health officials in Bangalore, Karnataka, are urging residents to get their flu vaccinations. The seasonal flu, while common, can lead to severe health complications, particularly for vulnerable populations such as young children, the elderly, and those with underlying health conditions.
Dr. Vidisha Kumari, a leading epidemiologist in Bangalore, emphasizes the importance of getting vaccinated. "The flu vaccine is our best defense against the influenza virus. It not only protects individuals but also helps prevent the spread of the virus in our communities," he says.
This year, the flu season is expected to coincide with a potential increase in other respiratory illnesses. The Karnataka Health Department has launched an awareness campaign highlighting the significance of flu vaccinations. They have set up multiple vaccination centers across Bangalore, making it convenient for residents to receive their shots.
To encourage widespread vaccination, the government is also collaborating with local schools, workplaces, and community centers to facilitate vaccination drives. Special attention is being given to ensuring that the vaccine is accessible to all, including marginalized communities who may have limited access to healthcare.
Residents are reminded that the flu vaccine is safe and effective. Common side effects are mild and may include soreness at the injection site, mild fever, or muscle aches. These side effects are generally short-lived and far less severe than the flu itself.
Healthcare providers are also stressing the importance of continuing COVID-19 precautions. Wearing masks, practicing good hand hygiene, and maintaining social distancing are still crucial, especially in crowded places.
Protect yourself and your loved ones by getting vaccinated. Together, we can help keep Bangalore healthy and safe this flu season. For more information on vaccination centers and schedules, residents can visit the Karnataka Health Department’s official website or follow their social media pages.
Stay informed, stay safe, and get your flu shot today!
Prix Galien International 2024 Forum ProgramLevi Shapiro
June 20, 2024, Prix Galien International and Jerusalem Ethics Forum in ROME. Detailed agenda including panels:
- ADVANCES IN CARDIOLOGY: A NEW PARADIGM IS COMING
- WOMEN’S HEALTH: FERTILITY PRESERVATION
- WHAT’S NEW IN THE TREATMENT OF INFECTIOUS,
ONCOLOGICAL AND INFLAMMATORY SKIN DISEASES?
- ARTIFICIAL INTELLIGENCE AND ETHICS
- GENE THERAPY
- BEYOND BORDERS: GLOBAL INITIATIVES FOR DEMOCRATIZING LIFE SCIENCE TECHNOLOGIES AND PROMOTING ACCESS TO HEALTHCARE
- ETHICAL CHALLENGES IN LIFE SCIENCES
- Prix Galien International Awards Ceremony
Tom Selleck Health: A Comprehensive Look at the Iconic Actor’s Wellness Journeygreendigital
Tom Selleck, an enduring figure in Hollywood. has captivated audiences for decades with his rugged charm, iconic moustache. and memorable roles in television and film. From his breakout role as Thomas Magnum in Magnum P.I. to his current portrayal of Frank Reagan in Blue Bloods. Selleck's career has spanned over 50 years. But beyond his professional achievements. fans have often been curious about Tom Selleck Health. especially as he has aged in the public eye.
Follow us on: Pinterest
Introduction
Many have been interested in Tom Selleck health. not only because of his enduring presence on screen but also because of the challenges. and lifestyle choices he has faced and made over the years. This article delves into the various aspects of Tom Selleck health. exploring his fitness regimen, diet, mental health. and the challenges he has encountered as he ages. We'll look at how he maintains his well-being. the health issues he has faced, and his approach to ageing .
Early Life and Career
Childhood and Athletic Beginnings
Tom Selleck was born on January 29, 1945, in Detroit, Michigan, and grew up in Sherman Oaks, California. From an early age, he was involved in sports, particularly basketball. which played a significant role in his physical development. His athletic pursuits continued into college. where he attended the University of Southern California (USC) on a basketball scholarship. This early involvement in sports laid a strong foundation for his physical health and disciplined lifestyle.
Transition to Acting
Selleck's transition from an athlete to an actor came with its physical demands. His first significant role in "Magnum P.I." required him to perform various stunts and maintain a fit appearance. This role, which he played from 1980 to 1988. necessitated a rigorous fitness routine to meet the show's demands. setting the stage for his long-term commitment to health and wellness.
Fitness Regimen
Workout Routine
Tom Selleck health and fitness regimen has evolved. adapting to his changing roles and age. During his "Magnum, P.I." days. Selleck's workouts were intense and focused on building and maintaining muscle mass. His routine included weightlifting, cardiovascular exercises. and specific training for the stunts he performed on the show.
Selleck adjusted his fitness routine as he aged to suit his body's needs. Today, his workouts focus on maintaining flexibility, strength, and cardiovascular health. He incorporates low-impact exercises such as swimming, walking, and light weightlifting. This balanced approach helps him stay fit without putting undue strain on his joints and muscles.
Importance of Flexibility and Mobility
In recent years, Selleck has emphasized the importance of flexibility and mobility in his fitness regimen. Understanding the natural decline in muscle mass and joint flexibility with age. he includes stretching and yoga in his routine. These practices help prevent injuries, improve posture, and maintain mobilit
Couples presenting to the infertility clinic- Do they really have infertility...Sujoy Dasgupta
Dr Sujoy Dasgupta presented the study on "Couples presenting to the infertility clinic- Do they really have infertility? – The unexplored stories of non-consummation" in the 13th Congress of the Asia Pacific Initiative on Reproduction (ASPIRE 2024) at Manila on 24 May, 2024.
Report Back from SGO 2024: What’s the Latest in Cervical Cancer?bkling
Are you curious about what’s new in cervical cancer research or unsure what the findings mean? Join Dr. Emily Ko, a gynecologic oncologist at Penn Medicine, to learn about the latest updates from the Society of Gynecologic Oncology (SGO) 2024 Annual Meeting on Women’s Cancer. Dr. Ko will discuss what the research presented at the conference means for you and answer your questions about the new developments.
ARTIFICIAL INTELLIGENCE IN HEALTHCARE.pdfAnujkumaranit
Artificial intelligence (AI) refers to the simulation of human intelligence processes by machines, especially computer systems. It encompasses tasks such as learning, reasoning, problem-solving, perception, and language understanding. AI technologies are revolutionizing various fields, from healthcare to finance, by enabling machines to perform tasks that typically require human intelligence.
These lecture slides, by Dr Sidra Arshad, offer a quick overview of physiological basis of a normal electrocardiogram.
Learning objectives:
1. Define an electrocardiogram (ECG) and electrocardiography
2. Describe how dipoles generated by the heart produce the waveforms of the ECG
3. Describe the components of a normal electrocardiogram of a typical bipolar leads (limb II)
4. Differentiate between intervals and segments
5. Enlist some common indications for obtaining an ECG
Study Resources:
1. Chapter 11, Guyton and Hall Textbook of Medical Physiology, 14th edition
2. Chapter 9, Human Physiology - From Cells to Systems, Lauralee Sherwood, 9th edition
3. Chapter 29, Ganong’s Review of Medical Physiology, 26th edition
4. Electrocardiogram, StatPearls - https://www.ncbi.nlm.nih.gov/books/NBK549803/
5. ECG in Medical Practice by ABM Abdullah, 4th edition
6. ECG Basics, http://www.nataliescasebook.com/tag/e-c-g-basics
Ethanol (CH3CH2OH), or beverage alcohol, is a two-carbon alcohol
that is rapidly distributed in the body and brain. Ethanol alters many
neurochemical systems and has rewarding and addictive properties. It
is the oldest recreational drug and likely contributes to more morbidity,
mortality, and public health costs than all illicit drugs combined. The
5th edition of the Diagnostic and Statistical Manual of Mental Disorders
(DSM-5) integrates alcohol abuse and alcohol dependence into a single
disorder called alcohol use disorder (AUD), with mild, moderate,
and severe subclassifications (American Psychiatric Association, 2013).
In the DSM-5, all types of substance abuse and dependence have been
combined into a single substance use disorder (SUD) on a continuum
from mild to severe. A diagnosis of AUD requires that at least two of
the 11 DSM-5 behaviors be present within a 12-month period (mild
AUD: 2–3 criteria; moderate AUD: 4–5 criteria; severe AUD: 6–11 criteria).
The four main behavioral effects of AUD are impaired control over
drinking, negative social consequences, risky use, and altered physiological
effects (tolerance, withdrawal). This chapter presents an overview
of the prevalence and harmful consequences of AUD in the U.S.,
the systemic nature of the disease, neurocircuitry and stages of AUD,
comorbidities, fetal alcohol spectrum disorders, genetic risk factors, and
pharmacotherapies for AUD.
3. your laser specialist
3 of 16
SUPERIOR QUALITY & LONGEVITY
In collaboration with Dr Fankhauser, Meridian launched the first commercial
Nd:YAG laser in 1982. The MR Q SLT has built-in DNA, the Microruptor II legacy,
synonymous with innovation, reliability, and efficacy.
Meridian Medical MR Q SLT combines a powerful Nd:YAG with SLT
photoregeneration and provides the possibility to couple with Meridian
photocoagulators.
Meridian Medical carefully selects the best European components and technology
to assemble its lasers. We offer our users a robust and reliable unit. The MR Q
SLT housing is made of a high-grade aluminium monobloc that gives unique solid
feeling and dust-free electronics.
Sample Image of MR Q SLT with a single column table
4. your laser specialist
4 of 16
USABILITY
The MR Q SLT features a powerful dual laser module with a Nd:YAG laser combined with
an accurate SLT photoregenerator.
Featuring a 7” touch display control panel. Placed on either side of the table, users can
easily see the laser parameters and select between the laser mode, burst and offset
options.
The V-split mirror tower (optional feature) allows coaxial Nd:YAG treatments. This tower
enables a red reflex that results in retro illumination of the posterior capsule, ideal for
premium IOL treatments.
The laser head and slit lamp knobs are ergonomically placed on each side of the slit lamp.
The MR Q SLT has proven to be effective in treating open-angle glaucoma as primary
therapy, see chart “recommended settings” on page 10.
5. your laser specialist
5 of 16
SAFETY
MR Q SLT has built-in features assuring better treatments, safer laser offset and
quicker response.
The digital anterior and posterior offset allows the user to visualise where the laser
focus is and provides a clear warning when the anterior offset is selected, minimising
user error.
The control panel requires double confirmation to safely swap between laser modes
and the screen changes colour for a visual queue.
The electronically controlled offset resets to posterior 100 μm after the laser enters
on Stand-by; this unique feature minimises the risk of shooting at the wrong position,
avoiding the risk of lens pitting.
The red reflex(1)
resulting from the retro illumination of the posterior capsule optimises
the on-axis capsulotomy. This feature allows seamless evaluation of the capsulotomy
edges’ integrity, shape, and position in relation to the premium multifocal IOL rings,
with a higher degree of success and increasing patient satisfaction.
(1) De Vries, N., Nuijts, R., Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects, Points de Vue, Interna-
tional Review of Ophthalmic Optics, N64, Spring 2011
6. your laser specialist
6 of 16
FLEXIBILITY & COMFORT
The MR Q SLT features a twin-column table with a large tabletop. This presentation
eases patients’ access in wheelchairs and offers perfect working space for the
treating doctor.
The unique chinrest design ensures a comfortable, relaxed, and ergonomic position
for the patient during treatment while the user has unobstructed access to the
patient.
The slit lamp offers an optional tonometer post to use the unit as a diagnostic
device.
Meridian engineers can access the MR Q SLT remotely, offering a unique online
service to assess and provide calibration at almost any time of the day(*).
(*) world time zone may affect the availability of our technicians
Sample image of MR Q SLT with a twin-column table
7. your laser specialist
7 of 16
LASER EXCELLENCE
The history of Meridian AG, now showing up as Meridian Medical Group, and the
history of the medical Nd:YAG laser are closely connected. The Microruptor II,
developed by Meridian engineers and Prof. Dr. Franz Fankhauser († 2020), changed
the way of many ophthalmology treatments.
New technology is continuously developed and patented by our development
engineers. We select and integrate the best Swiss and European laser components
to ensure the highest quality and long-term reliability. We use tested and reliable best
practices in engineering and integration, ensuring our systems’ highest performance.
Our highly skilled and experienced staff works to deliver the service and results
our customers deserve and have come to expect.
TIPS FOR YOUR LASER
■ Yearly maintenance service assures the optimal performance of your laser
■ Follow the safety advice of the manufacturer and your regulatory body
■ Only use the laser as described in the IFU
CLINICAL INDICATION
For posterior capsulotomy, iridotomy and selective laser trabeculoplasty.
8. your laser specialist
8 of 16
BINOCULARS IN FOCUS
Each user must have the oculars set for their personal refraction, this way the laser will be in
parfocality with the aiming beam and retina. Defocused slit lamp may result in unpredictable
laser burns.
ABOUT THE OFFSET
Laser energy travels towards the point of emission (to the front of the eye), when shooting
on zero-offset the risk of lens pitting increases. Always check the offset before perform any
treatment.
9. your laser specialist
9 of 16
Nd:YAG TREATMENT GUIDELINES*
These guidelines have been prepared following industry standards for Nd:YAG treatments, the use of the laser and its
parameters are responsibility of the treating ophthalmologist.
Procedure Power (mJ) Offset Pulses
Posterior Capsulotomy (with lens) 0.9 – 2.0 Posterior 200 Single
Posterior Capsulotomy (w/o lens) 1.4 – 2.5 Posterior 200 Single
Peripheral Iridotomy 3.0 – 5.0 Posterior 100 Double-Triple
Peripheral Iridotomy (plateau iris) 5.0 – 7.0 Posterior 200 Triple
* Weiblinger RP. Review of the clinical literature on the use of the Nd:YAG laser for posterior capsulotomy. J Cataract Refract Surg. 1986 Mar;12(2):162-70.
Nd:YAG OTHER TREATMENTS*
Although the MR Q clinical evaluation did not contemplate these parameters, the following are treatments described for
Nd:YAG use
Anterior Capsulotomy 0.5 – 1.0 0 Single
Vitreous Strands (anterior) 2.0 – 3.0 Posterior 100 Single
IOL Surface Cleaning 0.3 Anterior 100 Single
* Weiblinger RP. Review of the clinical literature on the use of the Nd:YAG laser for posterior capsulotomy. J Cataract Refract Surg. 1986 Mar;12(2):162-70.
10. your laser specialist
10 of 16
MR Q SLT RECOMMENDED SETTINGS
The SLT has proven to be effective in treating open-angle glaucoma as primary therapy(1)
, according to the European
Glaucoma Society.
The recommended settings and procedures(2)
are as follow:
Laser parameters SLT mode
Spot size 400 μm
Exposure 3 ns (fixed)
Power 0.4 to 1.2 mJ according to the desired reaction: in heavily pigmented TM start with low
levels e.g. 0.4 mJ
Optimal reaction The power is titrated until the appearance of tiny air bubbles, “champagne bubbles”, at
the site of the laser burn, then the power is reduced by increments of 0.1 mJ until there
are no visible bubbles(1)
Number of spots 50 – 100 non-overlapping spots spaced over 180° – 360°
(1) Gazzard G, Konstantakopoulou E, Garway-Heath D, Garg A, Vickerstaff V, Hunter R, Ambler G, Bunce C, Wormald R, Nathwani N, Barton K, Rubin G, Buszewicz M; LiGHT Trial Study Group.
Selective laser trabeculoplasty versus eye drops for first-line treatment of ocular hypertension and glaucoma (LiGHT): a multicentre randomised controlled trial. Lancet. 2019 Apr 13;393(10180):1505-
1516. doi: 10.1016/S0140-6736(18)32213-X. Epub 2019 Mar 9. Erratum in: Lancet. 2019 Jul 6;394(10192):e1. PMID: 30862377; PMCID: PMC6495367.
(2) European Glaucoma Society, Terminology and guidelines for glaucoma, 5th
edition 2020.
11. your laser specialist
11 of 16
STANDARD ACCESSORIES
■ Laser safety sign
■ Safety goggles
■ Dust cover
OPTIONAL ACCESSORIES
■ Foot-switch
■ Single port beam splitter
■ Co-observation tube
■ Adapter for ½” digital camera
Sample Image of MR Q SLT with a single column table
12. your laser specialist
12 of 16
TECHNICAL SPECIFICATIONS*
Device description Nd:YAG mode SLT mode
Laser source Q-switched, solid state Nd:YAG 1064 nm Q-switched, solid state frequency
doubled
Nd:YAG 532 nm
Pulse duration 4 ns (typical) 3 ns (typical)
Pulse setting 1, 2 or 3 pulses Single pulse only
Maximum repetition rate Up to 3 Hz Up to 3 Hz
Maximum energy 32 mJ 0.3 to 2 mJ per pulse
Energy steps (single pulse)
Energy steps (double pulse)
Energy steps (triple pulse)
0.1 (0.3-2 mJ), 0.2 (2-5 mJ), 0.5 (5-10 mJ), 1 (10-12 mJ)
0.2 (0.6-4 mJ), 0.4 (4-10 mJ), 1 (10-20 mJ), 2 (20-22 mJ)
0.3 (0.9-6 mJ), 0.6 (6-15 mJ), 1.5 (15-30 mJ), 2 (30-32 mJ)
Continuously variable
Treatment spot size < 10 μm 400 μm
Cone angle 16° < 3°
Treatment beam offset range Electronic controlled, anterior 150 μm, 300 μm
posterior 0 μm, 100 μm, 200 μm, 300 μm
Not applicable
Aiming beam Red diode. Dual Beam. 635 nm Red Diode. 635 nm
Magnification 6 ×; 10 ×; 16 ×; 25 ×; 40 ×
Cooling system Air cooled
Weight ca. 30 kg (unpacked)
Power rating 100 – 240 VAC, 50 / 60 Hz
Dimensions H ×W ×D 700 mm x 800 mm x 440 mm
Connection ports USB for remote service and calibration
Basic UDI-DI 383007498MTLSXX1XG
* All technical specifications are subject to change without notice. In accordance with the international laser safety standards: IEC 60601-1:2005/A2:2020, IEC 60601-1-2:2014/A1:2020, MDR Regulation (EU) 2017/745