R.ANBARASAN ELECTRICAL COMMISSIONING ENGINEER
Page 1
 : +971508385793/+971551551747
E-mail : anbu.cdm@gmail.com
A professional Electrical Engineer specializing in Electrical equipments installation, supervision, testing &
commissioning, maintenance with more than 8 years of experience working with reputed firms, where I have
commissioned various substation, industrial & power plant equipments with high quality of work & HSE
standards.
Looking for a challenging job profile of an Electrical Engineer with an organization, where my experience,
skills and knowledge can be brought to effective use for contributing towards organizational growth and
personal development.
A) PERSONAL INFORMATION
Name : Anbarasan Rajadurai
Date of Birth : 04/06/1985
Qualification : B.E Electrical and Electronics
Passport Number : G3056968
Marital Status : Single
UAE Driving License : 2234227 valid up to 2025
B) Professional Experience
 Currently Working as Senior Engineer Electrical (Testing & Commissioning) in M/s Control & Application
Emirates, Abu Dhabi (UAE) from August 2013 to till date.
 Worked as Senior Engineer (Testing & Commissioning) in M/s Larsen &Toubro Ltd, Abu Dhabi (UAE) from
October 2008 to August 2013.
 Worked as Testing Engineer in M/s Anita Power Tech, Qatar from May 2008 to July 2008.
 Worked as Senior Testing Engineer in M/s INEL Power System Engineers (P) Ltd, Bangalore from
November 2006 to May 2008.
R.ANBARASAN ELECTRICAL COMMISSIONING ENGINEER
Page 2
Duties and Responsibilities:
 Responsible for testing and commissioning of substation, power plant electrical equipments rated from
400V to 400kV
 Responsible for Preventive maintenance, testing and commissioning of substation, power plant
equipment’s like panels, switchgear, Transformers, Battery systems, Capacitor Bank as per scheduled
plan in primary substations.
 Attend to technical snags and shutdown jobs in Live feeders, and resolve them as soon as possible
 SCMS & DMS signal list verification, scheme modification as per the approved signal list and signal
initiation from field
 Preparing Test Formats & Method Statements for various testing activities as per the standard and client
requirement.
 Co-ordination with Client/Consultant and vendor for execution of various testing activities.
 Prepare and maintain file system of site test reports, as built drawings, calibration certificates & operation
manuals of all test equipments,
 Testing & periodic maintenance schedules, vendor details, service agreements, record of technical
snags
 Coordinate with site team for startup and execution of project
 Assist other teams working for minimization redundancy and idle-time
 Preparation of training manuals and conducting training for new employees
 Ensure that EHS standards are followed by all team members working in site
 Study FEED, TB and TC document & Specification Document verification and submission for client
approval
 Vendor TBE document verification and submission for approval
 Shutdown & Changeover Philosophy preparation & submission
 Review SLD, Preliminary & Detailed Engineering documents
 Attending FAT witness for Switchgears, Power Transformers, PMS panels & Power Cables
Brief Explanation of Testing Commissioning Activities:
With conforming latest standards, safety Rules, permit to work and live plant regulations
 Testing and Commissioning, Preventive Maintenance Testing, Calibration of
 All leading make Protection (Back Up Relays), Auxiliary Relays
 Power, Distribution Transformers
 Capacitor Banks, NGRs, NERs
 CTs, CVTs, VTs, CBs, Isolators, LA, Wave Traps, LT & HT SWGRs
 High Voltage AC, DC & VLF Testing of HV Cables
 LVAC, ACDB, DCDB, Battery, Battery Chargers
 C&R Panels, APFC panel, Transformer Interlocking panel and its Associates
 Tri-vector, KW, KVAR, KVA, A, V, PF, & HZ Meters, and Various Transducers
 LV System (DB, SMDB, Bus Ducts, CBCTs, ELR) as per ADDC wiring regulations
 Control & Protection schemes (Diff, REF, SBEF etc.) and operation schemes & interlocks like ATS
 Stability Tests of Transformer, Bus Bar Differential Protections, REF Protections
 Scheme Checking and Correction suggestions in Drawing and Cable Schedules
 Preparation, Testing, Modification, Troubleshooting of different Protection, Control, Interlock Schemes
 Supervision of HV, LV Power Cables laying, termination, interconnection wiring between yard equipments
and control panels, AVR panels etc.
R.ANBARASAN ELECTRICAL COMMISSIONING ENGINEER
Page 3
Competencies:
 In-depth knowledge of testing, commissioning, operation, and maintenance of electrical power system
 Knowledge on local authorities’ specifications and requirements
 Engineering and review of Specification Documents, Technical Data sheet, SPIR list, Preliminary
Documents, Vendor Documents (Basis of Design, GA, SLDs, Bus Wiring schemes, Interlock Logic
schemes, Detailed Schematic)
 Trained about Basic First AID, Fire Fighting & H2S/BA awareness Job performer courses
 Team Management, Interpersonal & Training skills
 Proficient in verbal and written communication skills
Testing Equipments Used:
 Omicron CMC356,256 Plus, Freja306, Freja 300, Sverker760, ISA Relay Test kits
 Programma TM1600-MA, TM1720 / Scope make SCOT MXP CB test kits
 ELTEL Tan delta test kit
 Omicron, Vanguard make CT Analyzers
 Megger make TTR310, DLRO600, DLRO 10 test kits
 HV Inc., HV Diagnostics, Phenix, ELTEL make HV AC, DC and VLF testing Kits up to 160kV
 Eltel make Winding resistance measurement kits
 Baur make SHIRLA, PGK 25, CL20 Test Kits
 Omicron (CPC100+CPTD1+CP CB2), Programma ODEN AT make Primary Injection Test Kits
 Various conventional Primary injection, Relay, Meter test kits, Timers, Phase shifters & aux supply source
kits
Major Assignments Handled:
Gulf Experience:
 ADW465 – ADMA Switchgear Upgrade Project
Client – Abu Dhabi Gas Liquefaction Company Ltd. (ADGAS)
Scope of Work - replacement of the existing 11kV and 415V switchboards in ADMA Power Station with
a new 33kV, 11kV and 415V Switchboards in a new building, shifting of Generator Feeder from
existing 33kV ADGAS switchgear to new 33kV ADMA switchgear, shifting of existing 2nos. 11kV
generator feeder to new 33kV ADMA switchgear with new 11/33kV Step-up transformer associated
New PMS& LMS panel (SIEMENS), interfacing with existing ADGAS PMS, LMS, DCS (Presently in Project
as Engineering Support)
 ADW455 – ADCO EPC for Replacement of 11 kV Switchgear Panels at NEB Fields
Client – Abu Dhabi Company for Onshore Oil Operations (ADCO)
Scope of Work - replacement of the existing 11kV switchgear with New 11kV Switchgear ABB Unigear
ZS1 (31 panels) in 15days shutdown schedule (Demolition of old Switchgear, Installation, Testing and
Commissioning) and associated power cable re-routing, cable jointing, cable testing, Signals to EDSS
& DCS testing.
 Buhasa 11/3.3KV Network Upgrade and Modification GASCO Project No.: 0300468
Client – GASCO
R.ANBARASAN ELECTRICAL COMMISSIONING ENGINEER
Page 4
Electrical Equipment –Demolition of existing 11kV Switchgear and replacing with new 11kV Switchgear
Schneider Electric- Set, 15MVA Power Transformer Schneider and associated SCMS, PMS & DCS
modification.
 N7203 132kV Substation Reinforcement Work – Abu Dhabi
Client – TRANSCO/ADDC
Electrical Equipment – 33kV Switchgear GIS Siemens 8DB10, 33kV Protection Panel Scheme &
Functional checks.
 N7133 132/11kV Substation Sir Baniyas Island – Abu Dhabi
Client – TRANSCO/ADDC
Electrical Equipment – 11kV Switchgear GIS Siemens 8DA10, Various Components like CT, VT, CBs,
Meters, Back up Relays,Auxiliary Transformer, 6MVAr Capacitor Bank associated Control panel,
Scheme, Functional checks & Up to SCMS Signal test, DAD-N High Impedance Bus Bar stability.
 D101733 Urgent Power Supply for Palace – Abu Al Abayad Island – Abu Dhabi
Client – ADDC
Electrical Equipment – 33/11kV 2nos. Package Units – 15MVA Power Transformer ABB, 33kV & 11kV
Switchgear associated Components, panel scheme & functional checks, scheme modifications and
commissioning.
 D9441 Power Network Development for Al Aryam Island – Abu Dhabi
Client – ADDC
Electrical Equipment – 33/11kV 3nos. Package Units – 10MVA Brush Transformers, 33kV GIS Schneider
Electric, 11kV AIS ABB associated components, scheme, functional checks, RTU Based DMS signals
modification & Verification, RED670 Line Stability, End to End Test & RET670 Transformer stability.
 A3900 Associated Remote End Modification – AlAin
Client – AADC
Electrical Equipment – Existing Old 33kV AIS switchgear Demolition & Installation of New 33kV GIS
8DA10 switchgear under Shutdown associated 15MVA existing Transformer Signals, protection
modification, Components, Panel Scheme & Protection panel Functional checks, SCMS signals
verification in two stages.
 D6624 – Power Network Development in Western Region – Abu Dhabi
Client – ADDC
Electrical Equipment – 33/11kV Primary substations 2nos. 20MVA Power Transformer, 33kV GIS 8DA10
Siemens, 11kV AIS ABB components, scheme, functional checks, 6MVAr Capacitor Bank & control
panel, RTCC Transformer Parallel interlocking panel, SCMS Signal modification and verification,
associated Remote Grid End Retrofit work of replacing existing pilot wire protection relay with RED670
Cable differential Protection relay, End to End test, Line stability, RET670 transformer stability, DAD-N
Bus Bar stability, SCMS/DMS Signal test.
 A3486 – Power Network Development in AlAin Network – Alain
Client – AADC
Electrical Equipment – 6nos. of 33/11kV Primary Substations testing of 20MVA Power transformer
AREVA, 33kV GIS AREVA WS Switchgear, 11kV AIS ABB Unigear ZS1 Switchgear components testing,
scheme & functional checks, Protection panel auxiliary relays, scheme & functional checks.
 Phase VII – 66/11kV substation – Qatar
Client – KHARAMA
Electrical Equipment - Scheme & Functional Checks for 66kV Protection Panel, 11kV AIS switchgear,
LVAC switchgear.
R.ANBARASAN ELECTRICAL COMMISSIONING ENGINEER
Page 5
Experience in India:
 400/220/33KV PGCIL substation Hassan through L&T
 220/11KV S/S for cement plant at M/s Ultratech Cements through M/s. ABB ltd.
 220/132/33KV CSEB S/S at Champa C.G thru M/s. EMCO ltd, Mumbai.
 220/132/33KV CSEB S/S at Mahasamund, C.G thru M/s. EMCO ltd, Mumbai.
 220/6.6/0.415KV S/S at M/s NPCIL 2500MW Atomic power plant 3 & 4, Kaiga Karnataka through M/s
Reliance Energy ltd.
 220/66/11KV KPTCL S/S, Bangalore through M/s Melcon Engineers.
 400/132KV PGCIL substation Goothi through Tata Power Projects.
Annual Maintenance Testing Experience:
Preventive (Pre Cautionary) Maintenance testing of various equipments (Transformers, Relays, Meters, CTs, PTs,
CBs, Cables, and Capacitor Banks) done at various sites, plants, and industries are as follows
 M/s IOCL, Mathura (M.P).
 M/s GEM sugars, Bagalkot (K.N)
Significance Highlights:
 Awarded Conscious Testing Engineer in Remote End at A3900.1 project for L&T HSE Safety Month
Jan2011.
 Awarded Conscious Testing Engineer in Substation at N7133 project for L&T HSE Safety Month Jan2013.
 Conducted PowerPoint presentation for ADDC Operation Engineer for NOVA38 Recloser
(sectionalizer) at D9441 project.
Approvals and Certifications:
 Originator Certification from GASCO
 Competency Certification & approvals from ADDC, AADC
(ADDC, AADC are Government Electricity& Water Distribution Companies)
 Training on Basic First Aid, Basic Firefighting & H2S/BA Awareness Certification courses from GTSC, Abu
Dhabi
 “Certificate of Appreciation” from GASCO as “Commissioning Engineer” for Zero LTI in GASCO
ADW401 project
 H2S Competency Training course conducted on behalf of GASCO Buhasa Plant division from GHRDC
 Omicron Training on “Performing tests on Protection Relays with Omicron CMC test set”

ANBARASAN R CV

  • 1.
    R.ANBARASAN ELECTRICAL COMMISSIONINGENGINEER Page 1  : +971508385793/+971551551747 E-mail : anbu.cdm@gmail.com A professional Electrical Engineer specializing in Electrical equipments installation, supervision, testing & commissioning, maintenance with more than 8 years of experience working with reputed firms, where I have commissioned various substation, industrial & power plant equipments with high quality of work & HSE standards. Looking for a challenging job profile of an Electrical Engineer with an organization, where my experience, skills and knowledge can be brought to effective use for contributing towards organizational growth and personal development. A) PERSONAL INFORMATION Name : Anbarasan Rajadurai Date of Birth : 04/06/1985 Qualification : B.E Electrical and Electronics Passport Number : G3056968 Marital Status : Single UAE Driving License : 2234227 valid up to 2025 B) Professional Experience  Currently Working as Senior Engineer Electrical (Testing & Commissioning) in M/s Control & Application Emirates, Abu Dhabi (UAE) from August 2013 to till date.  Worked as Senior Engineer (Testing & Commissioning) in M/s Larsen &Toubro Ltd, Abu Dhabi (UAE) from October 2008 to August 2013.  Worked as Testing Engineer in M/s Anita Power Tech, Qatar from May 2008 to July 2008.  Worked as Senior Testing Engineer in M/s INEL Power System Engineers (P) Ltd, Bangalore from November 2006 to May 2008.
  • 2.
    R.ANBARASAN ELECTRICAL COMMISSIONINGENGINEER Page 2 Duties and Responsibilities:  Responsible for testing and commissioning of substation, power plant electrical equipments rated from 400V to 400kV  Responsible for Preventive maintenance, testing and commissioning of substation, power plant equipment’s like panels, switchgear, Transformers, Battery systems, Capacitor Bank as per scheduled plan in primary substations.  Attend to technical snags and shutdown jobs in Live feeders, and resolve them as soon as possible  SCMS & DMS signal list verification, scheme modification as per the approved signal list and signal initiation from field  Preparing Test Formats & Method Statements for various testing activities as per the standard and client requirement.  Co-ordination with Client/Consultant and vendor for execution of various testing activities.  Prepare and maintain file system of site test reports, as built drawings, calibration certificates & operation manuals of all test equipments,  Testing & periodic maintenance schedules, vendor details, service agreements, record of technical snags  Coordinate with site team for startup and execution of project  Assist other teams working for minimization redundancy and idle-time  Preparation of training manuals and conducting training for new employees  Ensure that EHS standards are followed by all team members working in site  Study FEED, TB and TC document & Specification Document verification and submission for client approval  Vendor TBE document verification and submission for approval  Shutdown & Changeover Philosophy preparation & submission  Review SLD, Preliminary & Detailed Engineering documents  Attending FAT witness for Switchgears, Power Transformers, PMS panels & Power Cables Brief Explanation of Testing Commissioning Activities: With conforming latest standards, safety Rules, permit to work and live plant regulations  Testing and Commissioning, Preventive Maintenance Testing, Calibration of  All leading make Protection (Back Up Relays), Auxiliary Relays  Power, Distribution Transformers  Capacitor Banks, NGRs, NERs  CTs, CVTs, VTs, CBs, Isolators, LA, Wave Traps, LT & HT SWGRs  High Voltage AC, DC & VLF Testing of HV Cables  LVAC, ACDB, DCDB, Battery, Battery Chargers  C&R Panels, APFC panel, Transformer Interlocking panel and its Associates  Tri-vector, KW, KVAR, KVA, A, V, PF, & HZ Meters, and Various Transducers  LV System (DB, SMDB, Bus Ducts, CBCTs, ELR) as per ADDC wiring regulations  Control & Protection schemes (Diff, REF, SBEF etc.) and operation schemes & interlocks like ATS  Stability Tests of Transformer, Bus Bar Differential Protections, REF Protections  Scheme Checking and Correction suggestions in Drawing and Cable Schedules  Preparation, Testing, Modification, Troubleshooting of different Protection, Control, Interlock Schemes  Supervision of HV, LV Power Cables laying, termination, interconnection wiring between yard equipments and control panels, AVR panels etc.
  • 3.
    R.ANBARASAN ELECTRICAL COMMISSIONINGENGINEER Page 3 Competencies:  In-depth knowledge of testing, commissioning, operation, and maintenance of electrical power system  Knowledge on local authorities’ specifications and requirements  Engineering and review of Specification Documents, Technical Data sheet, SPIR list, Preliminary Documents, Vendor Documents (Basis of Design, GA, SLDs, Bus Wiring schemes, Interlock Logic schemes, Detailed Schematic)  Trained about Basic First AID, Fire Fighting & H2S/BA awareness Job performer courses  Team Management, Interpersonal & Training skills  Proficient in verbal and written communication skills Testing Equipments Used:  Omicron CMC356,256 Plus, Freja306, Freja 300, Sverker760, ISA Relay Test kits  Programma TM1600-MA, TM1720 / Scope make SCOT MXP CB test kits  ELTEL Tan delta test kit  Omicron, Vanguard make CT Analyzers  Megger make TTR310, DLRO600, DLRO 10 test kits  HV Inc., HV Diagnostics, Phenix, ELTEL make HV AC, DC and VLF testing Kits up to 160kV  Eltel make Winding resistance measurement kits  Baur make SHIRLA, PGK 25, CL20 Test Kits  Omicron (CPC100+CPTD1+CP CB2), Programma ODEN AT make Primary Injection Test Kits  Various conventional Primary injection, Relay, Meter test kits, Timers, Phase shifters & aux supply source kits Major Assignments Handled: Gulf Experience:  ADW465 – ADMA Switchgear Upgrade Project Client – Abu Dhabi Gas Liquefaction Company Ltd. (ADGAS) Scope of Work - replacement of the existing 11kV and 415V switchboards in ADMA Power Station with a new 33kV, 11kV and 415V Switchboards in a new building, shifting of Generator Feeder from existing 33kV ADGAS switchgear to new 33kV ADMA switchgear, shifting of existing 2nos. 11kV generator feeder to new 33kV ADMA switchgear with new 11/33kV Step-up transformer associated New PMS& LMS panel (SIEMENS), interfacing with existing ADGAS PMS, LMS, DCS (Presently in Project as Engineering Support)  ADW455 – ADCO EPC for Replacement of 11 kV Switchgear Panels at NEB Fields Client – Abu Dhabi Company for Onshore Oil Operations (ADCO) Scope of Work - replacement of the existing 11kV switchgear with New 11kV Switchgear ABB Unigear ZS1 (31 panels) in 15days shutdown schedule (Demolition of old Switchgear, Installation, Testing and Commissioning) and associated power cable re-routing, cable jointing, cable testing, Signals to EDSS & DCS testing.  Buhasa 11/3.3KV Network Upgrade and Modification GASCO Project No.: 0300468 Client – GASCO
  • 4.
    R.ANBARASAN ELECTRICAL COMMISSIONINGENGINEER Page 4 Electrical Equipment –Demolition of existing 11kV Switchgear and replacing with new 11kV Switchgear Schneider Electric- Set, 15MVA Power Transformer Schneider and associated SCMS, PMS & DCS modification.  N7203 132kV Substation Reinforcement Work – Abu Dhabi Client – TRANSCO/ADDC Electrical Equipment – 33kV Switchgear GIS Siemens 8DB10, 33kV Protection Panel Scheme & Functional checks.  N7133 132/11kV Substation Sir Baniyas Island – Abu Dhabi Client – TRANSCO/ADDC Electrical Equipment – 11kV Switchgear GIS Siemens 8DA10, Various Components like CT, VT, CBs, Meters, Back up Relays,Auxiliary Transformer, 6MVAr Capacitor Bank associated Control panel, Scheme, Functional checks & Up to SCMS Signal test, DAD-N High Impedance Bus Bar stability.  D101733 Urgent Power Supply for Palace – Abu Al Abayad Island – Abu Dhabi Client – ADDC Electrical Equipment – 33/11kV 2nos. Package Units – 15MVA Power Transformer ABB, 33kV & 11kV Switchgear associated Components, panel scheme & functional checks, scheme modifications and commissioning.  D9441 Power Network Development for Al Aryam Island – Abu Dhabi Client – ADDC Electrical Equipment – 33/11kV 3nos. Package Units – 10MVA Brush Transformers, 33kV GIS Schneider Electric, 11kV AIS ABB associated components, scheme, functional checks, RTU Based DMS signals modification & Verification, RED670 Line Stability, End to End Test & RET670 Transformer stability.  A3900 Associated Remote End Modification – AlAin Client – AADC Electrical Equipment – Existing Old 33kV AIS switchgear Demolition & Installation of New 33kV GIS 8DA10 switchgear under Shutdown associated 15MVA existing Transformer Signals, protection modification, Components, Panel Scheme & Protection panel Functional checks, SCMS signals verification in two stages.  D6624 – Power Network Development in Western Region – Abu Dhabi Client – ADDC Electrical Equipment – 33/11kV Primary substations 2nos. 20MVA Power Transformer, 33kV GIS 8DA10 Siemens, 11kV AIS ABB components, scheme, functional checks, 6MVAr Capacitor Bank & control panel, RTCC Transformer Parallel interlocking panel, SCMS Signal modification and verification, associated Remote Grid End Retrofit work of replacing existing pilot wire protection relay with RED670 Cable differential Protection relay, End to End test, Line stability, RET670 transformer stability, DAD-N Bus Bar stability, SCMS/DMS Signal test.  A3486 – Power Network Development in AlAin Network – Alain Client – AADC Electrical Equipment – 6nos. of 33/11kV Primary Substations testing of 20MVA Power transformer AREVA, 33kV GIS AREVA WS Switchgear, 11kV AIS ABB Unigear ZS1 Switchgear components testing, scheme & functional checks, Protection panel auxiliary relays, scheme & functional checks.  Phase VII – 66/11kV substation – Qatar Client – KHARAMA Electrical Equipment - Scheme & Functional Checks for 66kV Protection Panel, 11kV AIS switchgear, LVAC switchgear.
  • 5.
    R.ANBARASAN ELECTRICAL COMMISSIONINGENGINEER Page 5 Experience in India:  400/220/33KV PGCIL substation Hassan through L&T  220/11KV S/S for cement plant at M/s Ultratech Cements through M/s. ABB ltd.  220/132/33KV CSEB S/S at Champa C.G thru M/s. EMCO ltd, Mumbai.  220/132/33KV CSEB S/S at Mahasamund, C.G thru M/s. EMCO ltd, Mumbai.  220/6.6/0.415KV S/S at M/s NPCIL 2500MW Atomic power plant 3 & 4, Kaiga Karnataka through M/s Reliance Energy ltd.  220/66/11KV KPTCL S/S, Bangalore through M/s Melcon Engineers.  400/132KV PGCIL substation Goothi through Tata Power Projects. Annual Maintenance Testing Experience: Preventive (Pre Cautionary) Maintenance testing of various equipments (Transformers, Relays, Meters, CTs, PTs, CBs, Cables, and Capacitor Banks) done at various sites, plants, and industries are as follows  M/s IOCL, Mathura (M.P).  M/s GEM sugars, Bagalkot (K.N) Significance Highlights:  Awarded Conscious Testing Engineer in Remote End at A3900.1 project for L&T HSE Safety Month Jan2011.  Awarded Conscious Testing Engineer in Substation at N7133 project for L&T HSE Safety Month Jan2013.  Conducted PowerPoint presentation for ADDC Operation Engineer for NOVA38 Recloser (sectionalizer) at D9441 project. Approvals and Certifications:  Originator Certification from GASCO  Competency Certification & approvals from ADDC, AADC (ADDC, AADC are Government Electricity& Water Distribution Companies)  Training on Basic First Aid, Basic Firefighting & H2S/BA Awareness Certification courses from GTSC, Abu Dhabi  “Certificate of Appreciation” from GASCO as “Commissioning Engineer” for Zero LTI in GASCO ADW401 project  H2S Competency Training course conducted on behalf of GASCO Buhasa Plant division from GHRDC  Omicron Training on “Performing tests on Protection Relays with Omicron CMC test set”