1. VIPINDAS K.M
S/O Mohandas
Kollara House
(PO) Kaipamangalam, kalamuri
Thrissur dist. Kerala, India - 680681
Mobile No: + 919020033255
Uganda No: + 256705772725
Email ID: vipindas4u@yahoo.com
Skype : vipin das
SUMMARY:
Electrical Eng. Diploma (with 65%) with experience in Electrical Engineering field including testing,
commissioning and maintenance of Numerical Relays and Electrical Equipments.
OBJECTIVE:
A challenging, successful and rewarding career in the field of Electrical Eng. in a progressive
organization sharpening own professional skills resulting in mutual development.
EMPLOYMENT PROFILE:
Year 2011-2013
Company : M/s. Areva T & D
(Private ltd) contract basis
: Service Engineer (Numerical Relay Testing & commissioning).
Year 2013 -2014
Company : M/s Power Net distribution solution.
Testing Engineer (Electrical Equipment’s testing & commissioning)
Year 2015 – Present : National contracting company rezayat group
Company Testing & commissioning engineer
EXPERIENCE PROFILE:
5 Year 2 months’ practicalexperience in Testing & Commissioning of electricalRelaysand equipment’s in
Oil and gas refineries , power plants, EHV substation .
.
LV & HV switchgear – Testing andcommissioning of relays, CTs and PTs , control and metering
circuits ,bus bars,breakersand different feedersand modules (Make: HV:M/s BHEL,LV : C&S,
L&T, ABB,Schneider etc)
Transformer Testing and Commissioning Including generator transformer (Make: M/s BHEL,
Areva, Voltamp, Emco.)
Generator and generator relay panel preliminary commissioning works and association in total
testing and commissioning.
Capable to operate relay kits omicron, doble, ponovo, Megger mprt, Kingsine k68i.
HV/LV motorstesting and commissioning including specialdrives like wall blowers, soot blowers
used in boilers and motor driven valves( Make: Rotork, Auma).
All power, control, instrumentation and networking cabling, termination and testing.
Alarm annunciation panels testing and commissioning.
2. Capable to do allnumericalrelay configurationstesting and commissioning (specialised in Micom &
sepam).
MAJOR PROJECTS COMPLETED:
M/S TATA STEEL JAMSHEDPUR
Micom P143, P922, P633 configuration as per 11kv AIS Areva panel scheme.
As per client relay coordination report checked the protections and verified.
Protections for feeder protection, under voltage, transformer differential.
Test reports prepared, verified with client and submitted.
Doble F6150 test kit is used to perform the test.
M/S POWER GRID CORPORATION LTD (PGCL)
Micom P444 distance protection for 400kv grid line retrofitting.
As per the line details and setting relay configured and did the bench test.
After checking the existing scheme replaced old relay with new Micom and hardwired.
Zone test, reach test, power swing, SOTF following test has been done.
Test kit used omicron 256 used to perform the test.
M/S MANGALORE REFINERY AND PETROCHEMICAL (MRPL)
Micom P139, P143, P242, P922, P521, P633.
Captive power plant BHEL 33kv, 11kv and C&S low voltage board around 300 nos relay.
After checking the scheme and relay co ordination report relay configured.
Protections for feeder protection, under voltage, line differential, motor protection and transformer
differential.
Test reports prepared, verified with client and submitted.
Test kit used omicron 256 used to perform the test.
M/S MANGALORE REFINERY AND PETROCHEMICAL (MRPL)
Testing for power transformer ct, pt, busbar Hi pot test, bus bar CRM, vacuum circuit breaker testing.
33 kV & 11 kV BHEL board momentary parallel scheme checking and internal bus wiring.
Testing pick up and drop off for the electromagnetic relay.
LV motor module scheme and operation checks.
Motorised valve (MOV) Auma & Rotork makes MOV testing and commissioning.
Cable Hi pot test for the different type feeders and the motor drives.
Motor testing like from 1 KW small motors to 2 MW boilers feed pump of the generator.
Supporting for the DCS team for their control checks.
Preparing the reports and approved by the client MRPL & EIL.
M/S MANGALOREREFINERYANDPETROCHEMICAL (MRPL) WATER TREATMENT PLANT
Testing for 3.5mva power transformer ct, pt, and, bus bar CRM.
415 V LV panel board scheme checking and parallel load share checking.
Configuring and testing of Schneider SEPAM S82 feeder and M 81 motor protection.
LV module scheme checking and commissioning for the lighting and LV motors.
Preparing the reports and approved by the client MRPL & EIL.
ABROAD
TANZANIA ELECTRICITY COMPANY (TANESCO) AFRICA SS 1
Total project work from the installation up to commissioning.
The project name W22 having 3 substations did for national contracting company Saudi (NCC).
3. Station 1 switch yard ILALASS 33/11kv one bay extension 15 MVA transformer installation internal &
wiring for the protection.
Oil filtration for the transformer and checking the BDV, PPM and DGA test alltest result found satisfactory
as per manufacturer Data’s.
33kv circuit breakerinstallation coupling the mechanism and SF6 gasfilling as per the name plate shown on
the CB.
Protection panel and RTCC panel installation as per the installation drawing.
After the scheme drawing checking prepared cable schedule for the total bay.
Precommissioining test carried out for the allout door equipments and protection relay EFACEC make and
SEL for the transformer protection.
All reports submitted, approved and energised the station.
TANZANIA ELECTRICITY COMPANY (TANESCO) AFRICA SS 2 & 3
Station 2 SOKOINE substation 33kv Schneider Germany GIS 10nos panel and 11kv 13nos AIS panel.
Scheme checking done forboth panel,inter panelwiring and allthe ct,pt, bus bar CRM, BUS HI POT test
and circuit breaker testing has been done.
All Schneider SEPAM relay configured and tested as per the setting.
Station 3 132/33 kV relay configuration and testing .33kv GIS Schneider SEPAM relay,SEL421,EFACEC
relays.
UGANDA ELECTRICITY TRANSMISSION COMPANY (UETCL) AFRICA
Bujagali up gradation 132Kv to 220 Kv project switch yard work.
Overview ofproject 2 NOS 250 MVA EMCO power transformer bay , ACSRmain bus 1 and bus 2 ,bus 1
& 2 with sectionalised. Control, protection and SCADAby SchneiderFrance Lattes.The 33 KVvoltagesis
taking from Tertial winding to 33 KV GIS Switch board from both power transformer.
After the scheme drawing studies.Prepared the control & protection cable schedule for the whole 220kv
switch yard.As perthe schedule cable laid and power the controlsupply and energised all the control panel
and equipments.
Checking the battery bank electrolyte level,density and each cell voltage as per the manufacturer data’s.
After that each cells connected in series and formed 110v battery bank of 2 sources.
For the testing purpose submitted the method statement ,testing procedure and testing schedule ,as per that
started the outdoorequipmentsCurrent transformer ,capacitance voltage transformer ,Disconnector ,Circuit
breaker,2 NOSPower transformer 250 MVA , auxiliary transformer , battery capacitance test for the
battery . (Equipments used OMICRON CPC 100, CT ANALAYSER, breaker timer, CRM, Kyoritsu
Megger, Multimeter, leakage tester.
Entire hard wired scheme checked and verified. Schneider relay configured and tested by Schneider
engineer. From my side witnessed and verified the configuration relay setting asper the relay co ordination
report. The relays tested Micom P139. P132 .P633 and bus bar protection P741 central unit and P742
peripheral unit.
After Schneider SCADA configuration performed end to end test with client .Checked all the signals,
measurements, controls with interlock all found ok.
Stability for the both transformer did and found stable.
Stability for the 220kv bus. Checked allthe individualzones with respective switching, noted the differential
current and restraining current, checked unstable & stable conditions found ok.
All test reports submitted to the client and verified.
EDUCATIONAL QUALIFICATIONS:
Sl.NoQualification Board/University Year Class
1 ElectricalAuto cad Cad city
2011
Distinction
2
Diploma in Electrical
Eng.
State Boardof Technical
Education Kerala State
2011
First class
3 SSLC Kerala state syllabus 2008 First class
4. TRANING ATTENDED AND COMPUTERLITERACY:
Areva T&D all numerical relay protection training: 3 Month: 2011
Computer Knowledge:Windows,MS Office & MSword,MS Excel,PageMaker,Photoshop,
CorelDraw,Internet and E-mail.
EFACEC PortugalSCADA and protection training for 2 weeks:2015
PERSONAL DETAILS:
Full Name : Vipindas K.M.
Age and DOB : 25 years, 05/04/1991
Sex : Male
Nationality : Indian
Marital Status : Single
Passport Details (India) : Passport No: J9440237
: Date if Issue: 09.12.2011
: Date of Expiry: 08.12.2021
Driving Licence : Two wheeler & LMV (Indian)
Languages known : English, Hindi, Malayalam, Tamil.
Mailing Address : S/O Mohandas Kollara (H) (p o) Kaipamangalam
: Thrissur Dt, Kerala St, India-680681
Telephone contact No. : +919020033255
E-mail id : vipindas4u@yahoo.com
DECLARATION:
I hereby declare that the details furnished above are true and correct to the best of my knowledge
and belief.
24/08/2016 VIPINDAS K.M