The document discusses two bearing failures on a tissue machine. The first failure resulted in damage to the bearing and journal. After this, PeakVue monitoring was added for all tissue machine rolls. The second failure showed up in PeakVue readings as multiples of turning speed and increased amplitude with louder noises. Inspection found the inner race was loose and the journal was severely worn. PeakVue helped diagnose the fault before complete failure.