1. PROFESSIONAL COMPETENCE
K.SIVACHANDRAN
72/29 STAR NAGAR
GANDHIJI PARK ROAD
MELUR-607 106,
TAMILNADU Email Id : sivaoceannr@gmail.com
Contact No:+966594305928
CAREER OBJECTIVE:
Aspiring for a career that places me in a challenging position with in a fast-paced and
Learning-oriented environment for developing my technical and interpersonal skill.
ACADEMIC CHRONICLE
QUALIFICATION YEAR OF
PASSING
INSTITUTION PERCENTAGE
B.E (EEE) 2010
Madha Engineering
College.
(Anna Universtiy)
60%
Diploma (EEE) 2007
Arulmigu kallagar
Polytechnic college, 74%
OBJECTIVE:
To obtain a career opening in the field of Electrial in an organization that will enable me to
contribute, learn and grow up the organization
SKILLS:
Transmission and Distribution protection(including teleprotection scheme,autoreclose
pilot wire differential protection) up to 380 KV
Transformer protection(including multi winding transformer and territoray transformer
type,Differential and Restricted earth fault,over fluxing ,harmonic protection) up to 502
MVA transformer
2. Reactor Protection(including Bus reactor&Line reactor Frequency protection combined
with over& under voltage ,Resticted earth fault protection) up to 125MVAR
Busbar protection(high impedence and low impedance on centralized and decentralized
schemes)
Breaker failure protection(single bus ,double bus,double+transfer bus Breaker and half
schemes)
Medium voltage protections(Load shedding schemes,under voltage & over voltage,under
frequency &over frequency instanstaneous &inverse over current protection,Directional
over current & earth fault protection)
Bay control unit interlocking and configuration(single bus ,double bus,double+transfer bus
Breaker and half schemes)
Transient fault Recorder , Dynamic system monitor ,SAS,Partial discharge monitoring
system record panel schemes
Technical Communication skills:
Device configuration,Masking I/O(configuration matrix),CFC chart using DIGSI softwere
Substaion automation system Testing(complete substation alaram& protection signals up
to control center ,Gateways and RTU & SCADA Including IEC61850, IEC60870-5-103,
104, etc
Create the new IEC61850 STATION and new digsi project and trouble shooting
communication protocols such as IEC61850.
EXPERIENCE:
4 Years 10 Months
WORKED COMPANIES:
SIEMENS COMPANY(INEL POWER SYSTEM) ,MUMBAI KALWA ,INDIA
Designation: Protection Engineer
Working Period: March 2012 to 2/10/2013 date (1 Years 7months)
ROMY TECH COMPANY,INDIA
Designation: Protection Engineer
Working Period: MaY 2010 to 2/3/2012 date (1 Years 11months)
S.S.E.M COMPANY ,SAUDI ARABIA
Designation: Protection Engineer
4. ANSI PROTECTION
FUNCTION
TYPE MAKE
87L,21/21N,68
50HS,50STUB
Line differential
Distance ,Power swing,(STUB)
Stub bus protection
Instantaneous high-
currenttripping (switch-onto-
fault)
7SD52
7SD53
SEL411L
REL670
RED670
P543,P545
SIEMENS
ABB
SEL
ALSTOM
50/50N,51/51N,50NS
/51NS,87N,50BF,49
Definite-time overcurrent
protection(phase/neutral)
Inverse-time overcurrent
protection(phase/neutral)
Sensitiveearthfaultprotection
High impedance
restrictedearth fault
protection
Breaker failure protection
Thermal overload protection
7SJ611 SIEMENS
67/67N,27/59,81O/U
25,46
Directional time-overcurrent
protection (definite/inverse,
phase/neutral),Directional
comparison protection
27/59 Under / Over Voltage
Protection.81O/U
Overfrequeny/underfrequenc
y protection ,25 Synchro-
check
46 Phase-balance current
protection (negative-sequence
protecti
7SJ62 SIEMENS
87T,24,87N Transformer Differential
protection,over excitation
protection Low/high-
impedance restricted earth
fault (REF)
7UT612 SIEMENS
87BB,50BF Busbar differential protection
Breaker failuere protection
7SS52 SIEMENS
25 Synchro check,
Bay control unit
7SJ63
7SJ64
7VK61
6MD66
SIEMENS
87L Pilot wire differential
Motor protection
7PG21111
/7SJG1115
MPR300
SIEMENS
L&T
5. Substation automation testing:
SAS genral alarm testing
HMI Measurment
BCU Tests
Bay operential Interlocking test from HMI
Engineering PC Communication with all IED s
HMI Alarm and signals for IED
HMI Control and monitoring Tests
SAS IED INTERFACE
Sequence of Event
Protection signals
Acceptence test
SCADA Closed Loop Test
SCADA Local test
Control center Alarams
Remote ends
Test Kits Handled:
OMICRON - CMC256, CMC353, CMC356.
CT Analyzer,CPC100,FREJA300,ISA T2000
High voltage testing kit.
Insulation resistor test kit
Relay Software :
DIGSI 4.87
PCM 600
MICOM S1 STUDIO
Commissioning:
I have commissioning up to 400 Kv 380 Kv& 220Kv&132Kv&66Kv& 33Kv&13.8Kv&11Kv
Local control cubicle and protection panel
R.T.C.C Panel ,Transformer local control panel
Reactors Panel
Teleprotection panel
Fault recorder panel
6. Alaram panels
Dynamic system monitor panel
Transformer mechanical protection&MDU unit
Switch gear panels
A.C.D.B& D.C.D.B Panels
Component Testing:
Current transformer
Voltage transformers
Auxilary relay testing
Isolator timing test
breaker timing test
Secondary injection test
cable testing
High voltage testing
Scheme handled:
ONE and HALF Breaker scheme
Double bus bar scheme
Single bus bar scheme
Substation handled:
Gas insulated substation
Outdoor substation
Switch gears
Project details:
Involved as a Team leader in testing of all the panels like 13.8Kv to 380Kv control, relay and
synchronizing panels at various clients some clients given below
Saudi Arabia
7. Project: ALLITH -380KV/110KV/13.8KV
Testing
Current transformer,voltage transformer,Primary injection,Secondary injection
Dewpoint test,Isolator timing test,Breaker timing tes,Precheck ,Scheme checking
MCB testing ,Auxilary relay test,Timer testing,
BCU:6MD664
Interlock checking, Synchrocheck,Acceptence test,Measurments,BI Thershold level check,
Final settings,Closed loop testing up to HMI,Configuration modification,Pre check
Configuration files( Device configuration,Masking I/O,control display,CFC,Power system
data ,Setting group Measurement calculation,synchronization,Goose signals,IEC 61850
station)
Panels:
All kind of protection panels Precheck and scheme checking and modifications ,Fault record
panels,ACDB,DCDB,HVAC Panels,Alarm panels
Protection relays:
7UT613-Transformer Protection
7SD52- Line differential protection
7SJ62-Directional earth fault
7SS52-Bus bar protection
7JS611-Over current
7VK61-Auto reclouser
7SJ804- Reactor over current
REF 615- Over current and earth fault
Auxilary relays:
Lock out relays,Trip relays,Supervison relays,PT fuse fail relays
Auxilary relays,Timers,
Substation automation testings:
Closed loop tests on BCU and protection relays,substation genral alarms Measur
Ments and co ordinate with SIEMENS Engineers and witness
Fiber optic cable connection from IED device to SAS
Fiber optic cable connection from IED device to Media converter
RJ45 cable connection B/W Station controllers ,GPS installed
PROJECTS IN KSA:
Substation
AL-SAFA 380/132/13.8Kv GIS (U.G) ABB&HYNDAI
380Kv-8DIA (72 Single pole Breaker) ,132Kv 59 Bays,13.8Kv 2 Bays
Transformer 502MVA -4 , 2MVA-3
AL-LITH 380/110/13.8Kv GIS(O.H.L)ABB&HYSOUNG
380Kv -4DIA (36 Single pole Breaker) ,110Kv 12 Bays,13.8kv 2 Bays
Transformer 502MVA -2 , 2MVA-2
8. KHAIA380/110/13.8KvGIS(U.G)HYNDAI&ABB
380Kv -5DIA (45 Single pole Breaker) 110KV 30 Bays, 13.8KV 52 Bays
Transformer 502MVA -3, 75MVA-6 2MVA-3
TAIF 380/110/13.8Kv GIS(O.H.L)ABB
380Kv -4DIA (36 Single pole Breaker) ,110Kv 13 Bays,13.8kv 2 Bays
Transformer 502MVA -2 , 2MVA-2
Remote End Substations:
9017S/S 380/132/13.8Kv GIS (U.G) ALSTOM
JDNS/S 380/110/13.8Kv (U.G) HITACHI
SHOAIBAH-3S/S 380/110/13.8Kv (U.G) ALSTOM
SAWAMLAHS/S AIS 110/33KV ABB
8058 S/S 132/33KV GIS MERLIN GERIN
8066S/S 132/33KV GIS MERLIN GERIN
Responsiilites:
Complete Design Review for Base Design and Detail Design for Control, Protection, SAS, TFR,
SOE, Annunciation and AC/DC auxiliary system
Preparation of Protection Single line diagrams by utilizing the single line diagram, PTS and
Tendering PLD.
Preparation of SAS, SCADA, Annunciation and SOE point lists
Preparation of AC/DC Single Line Diagram
Preparing the complete Interfacing and cable schedule & Termination Schedule.
Review of client comments on schematic drawings and incorporating the same as per tender and
scope requirements without affecting cost implication.
Making new design for logic in interlock as well as in control scheme according to the
requirements.
Co-ordination and correspondence with Vendors
Preparation of outage / permission to work requests with identifying the safe working limits and
safety grounds for HV and EHV systems during construction or modification activities.
Preparation of mark-up drawings and incorporating corrections / changes made during
commissioning.
INDIA:
9. Principle involvement in Testing of 132 KV UPPCL, Line Control & Relay Panels
including Testing & Programming of SIEMENS Numerical Relays like Distance Relay.
.Principle involvement in Testing of 220 KV PGCIL, Feeder Control & Relay Panels
including Testing & Programming of SIEMENS Numerical Relays like Distance Relay..
Principle involvement in Testing of 220 KV APGENCO, Control & Relay Panels including
Testing & Programming of SIEMENS Numerical Relays.
Principle involvement in Testing of 220/110/11 KV KPTCL, Transformer Control & Relay
Panel including Testing & Programming of SIEMENS Numerical Relays and AREVA
Relays.
Principle involvement in Testing of 220/132 KV Biharshariff (BSEB), line Control & Relay
Panels including Testing & Programming of SIEMENS Numerical Relay, AREVA Relays
and EASUN REYROLLE Relays.
Principle involvement in Testing of 400KV Adani Power LTD, line Relay Panels including
Testing & Programming of SIEMENS Numerical Relays, ABB Relay, AREVA
Electromechanical Relays.
Personal Information:
Full Name : sivachandran.k
DOB : July,6, 1987.
Gender : Male
Passport No :J5664802 Validty(3/3/2011 to 2/3/2021)
Driving license no :F/TN/59W/000586 Validity(6/6/2007 to 5/6/2017)
Languages : ENGLISH, TAMIL(Read, Write, Speak)
HINDI (Speak)
I hereby declare that all the information given above is authentic to the best of my
knowledge and that any misrepresentation by me in this application disqualifies my
candidature.
Thanking you
DATE:
PLACE:RIYADH(KSA)