This document provides information about sterilization methods and guidelines. It defines sterilization as a process that destroys all microorganisms. It discusses factors that influence sterilization efficacy like organism load and resistance. Physical sterilization methods covered are heat, radiation, filtration and ultrasonic sterilization. Chemical methods discussed are aldehydes, oxidizing agents, gas sterilization and plasma sterilization. It also covers Spaulding's classification of medical devices and recommended sterilization methods for critical, semi-critical and non-critical devices.
VIP Call Girl Sector 88 Gurgaon Delhi Just Call Me 9899900591
Ā
SRI AUROBINDO COLLEGE DENTISTRY DEPARTMENT STERILIZATION GUIDE
1. SRI AUROBINDO COLLEGE OF
DENTISTRY
DEPARTMENT OF PEDODONTICS
AND PREVENTIVE DENTISTRY
2. STERILIZATION
GUIDED BY:-
1. Dr. Bharath Bhushan Sir
2. Dr. Khushboo Barjatya Maāam
3. Dr. Binti Rani Chand Maāam
4. Dr. Preene Juneja Maāam
5. Dr. Abhilasha M. Tripathi Maāam
6. Dr. Hariom Meena Sir
SUBMITTED BY:-
Purva Bairagi ( 2017-2018) Batch
Roll no. 52
3. CONTENTS
ā¢ Introduction
ā¢ Definition of sterilization
ā¢ Factor influencing efficacy of sterilization
ā¢ Methods of sterilization
ā¢ Physical method
ā¢ Chemical method
ā¢ Sterilization control
ā¢ Spauldingās classification of medical devices.
4. INTRODUCTION
ā¢ Sterilization, disinfection, asepsis,and
decontamination are four separate but interrelated
terminologies, all aiming at removing or destroying
the microorganisms from materials or from body
surfaces.
5. DEFINITION
Sterilization is a process by which all living microorganisms,
either in vegetative or in viable spores form destroy/
removed from article, body surfaces or medium.
6. FACTOR INFLUENCEING EFFICACY OF
STERILIZATION
ā¢ Organism load: Larger microbial population , required more time to die.
ā¢ Nature of organisms: Resistant or susceptible.
ā¢ Concentration: of chemical agent
ā¢ Temperature: of heat sterilization
ā¢ Exposure time: is more ,better is the efficacy.
7. METHODS OF STERILIZATION
ā¢ Physical methods
1. Heat
2. Radiation
3. Filtration
4. Ultrasonic sterilization
ā¢ Chemical methods
1. Aldehydes
2. Oxidizing methods
3. Plasma sterilization
4. Gas sterilization
5. Chemical Vapour pressure
Sterilization (Chemiclaving)
8. HEAT
DRY HEAT
1. Red heat
2. Flaming
3. Incineration
4. Hot air oven
MOIST HEAT
1. At a temperature below 100Ā°C.
2. At a temperature of 100Ā°C
3. At a temperature above 100Ā°C
9. DRY HEAT: KILLS ORGANISMS BY DENATURATION OF PROTEIN OXIDATIVE DAMAGE OR BY
TOXIC EFFECT OF ELEVATED ELECTROLYTES.
ā¢ Red heat.: Long time exposure in flame till they
become red hot.
Inoculation wire/loops, tips of forcep
ā¢ Flaming: Short time exposure without allowing items
to become red hot.
Mouth of test tube.
ā¢ Incineration: converting the waste into ashes.
Incinerator (870Ā°-1200Ā°)is used.
Disposal of biomedical waste.
10. DRY HEAT
ā¢ Hot Air Oven: Most widely
used dry heat method. Holding
time160Ā° for 2 hours.
Used for:
1. Glassware like glass syringes,
petri dish, flasks, pipettes and
test tube.
2. Surgical instruments like
scalpels, forceps, etc.
3. Chemical, such as liquid
paraffin, fats, glycerol, and glove
powder, etc.
Types:- Conventional dry heat oven
Short cycle , high temperature dry
heat oven
11. MOIST HEAT: KILLS ORGANISM BY DENATURATION AND
COAGULATION OF PROTEIN.
ā¢ At temperature below 100Ā°C
ā¢ Pasteurization: used for control of microorganisms from milk.
Two methods:-
ā¢ Holder method:- 63Ā°C for 30 minutes
ā¢ Flash method:- 72Ā°C for 20 seconds and then rapid cooling to13Ā°Cor lower.
Water bath:- used for serum body fluid and vaccines (60Ā°C for 1 hour)
12. MOIST HEAT
Inspissation:- process of heating an
article at 80-85Ā°C for 30 minutes.
ā¢ Inspissator use.
ā¢ Principle: first exposure kills all the
vegetative forms , and in the
intervals between the heating the
remaining spores germinate into
vegetative forms which are then
killed on subsequent heating.
ā¢ Ues for: sterilization of egg based
media LJ media and serum based
media loefflerās serum slop.
13. MOIST HEAT
AT TEMPERATURE OF 100Ā°C
ā¢ Boiling: Boiling of water for 15 minutes. Mainly used as household measure .
Not effective.
ā¢ Steaming: exposure of items which get decompose at high temperature .
Steam at 100Ā°C for 90 minutes.
ā¢ Tyndallization or intermittent sterilization:- 100Ā°C for 20 minutes for 3
consecutive days.
Same as inspissation but it occur at 100Ā°C.
Used for serum egg and sugar containing media.
14. MOIST HEAT
AT TEMPERATURE ABOVE 100Ā°C
AUTOCLAVE
ā¢ Most widely used, rapid and effective method.
ā¢ Works on the principle of pressure cooker.
ā¢ Water boils when vapour pressure is equal to that of
the surrounding atmosphere . So , when atmosphere
raised the boiling temperature also raised.
Components of autoclave :- comprises of three parts
1. Pressure chamber
2. Lid have discharging tap saftey valve and pressure
gauge
3. Electrical heater
Types of autoclave:
1. Gravity displacement type (Horizontal and Vertical)
2. Positive pressure displacement type
3. Negative pressure displacement type
16. ā¢ Filtration:- used for air and water filtration.
Types:-
1. Earthenware candle filters
2. Membrane filters
3. Air filters
ā¢ Radiation:- Causes damage to DNA because it have
high penetration power
Ionizing radiation:- gamma rays( cold sterilization) X rays ,
cosmic rays.
Non ionizing rays:- infrared rays , UV rays.
Radiation use for sterilization of plastic syringes, swabs ,
culture plate, catheters, cannulas.
17. Ultrasonic sterilization
ā¢ Itās a safe and moder method for sterilization.
ā¢ Usually from 20 -40 kHz.
ā¢ Remove most tenacious deposits, in shortest time possible
ā¢ Less risk of cross contamination.
ā¢ Used for:- equipment of dental surgeries, hospital , chemical laboratories.
18. CHEMICAL METHODS OF STERILIZATION
. CHEMICAL STERILANT
ā¢ Classified into four group:- Chemical sterilant ,Low level disinfection
,Intermediate disinfectio, High level disinfections
ā¢ ALDEHYDES:- They are sporicidal.
Combine with protein and nuclei acid , inactive them
Formaldehydes, most commonly used as formalin. Used for preservation of
anatomical specimen, also formaldehydes used for fumigation of operation theaters
.
Glutaraldehydes is less toxic and less irritant than formaldehyde . So , it is used as
best steriliant for endoscopes , bronchoscopes, cytoscopes, tracheoscops.
19. CHEMICAL STERILANTS
OXIDIZING AGENTS
ā¢ Hydrogen peroxide act on DNA, Lipid , membrane.
ā¢ Effective concentration 3-6%, for spores10%
ā¢ Used in ventilator and contact lenses
ā¢ Paracetic Acid , more active, less than 1% is sporicidal.
ā¢ Used in hemodialyzer, also used to sterilize endoscopes
ā¢ Both also used as in plasma sterilization
20. Plasma sterilization:-
ā¢ Plasma refers to gases state consisting of ion , photon, free electron, and neutral
particle . These active agents kill microorganisms as well as spores.
ā¢ Plasma sterilizer is a device use to create a plasma state.
ā¢ Used for sterlization of surgical instruments.
21. Gaseous sterilization:-
ā¢ Ethylene oxide (ETO) widely used, combined with cell
protein . Have both microcidal and sporicidal activity.
High penetration power but highly inflammable and
carcinogenic.
Used for sterilization of petri dishes , syringes , sutures ,
catheters, respiratory and dental equipments.
ā¢ Betapropiolactone (BPL) also have sporicidal effect , it
is not used due to carcinogenic effect .
May be use for inactivation of vaccines.
22. BIOLOGICAL INDICATORS FOR STERLIZATION
Methods Indicators
Hot air oven Clostridium tetani nin toxic
strain
Autoclave Bacilkus sterarothermophilus
Filtartion Brevundimonas
Etylene oxide Bacillus globigi
Plasma sterilization Bacillus subtillis
Radiation Bacillus pumilus
23. Chemical vapour sterilization (Chemiclave)
ā¢ Uses special chemical solution, containing formaldehyde and
alchol.
ā¢ Operate at 131Ā°C at20 pounds for 30 minutes.
ā¢ Used for carbon steel bur , pliers
ā¢ Does not cause corrosion.
24. SPAULDINGāS CLASSIFICATION OF MEDICAL
DEVICES
Medical Devices Defination Examples Recommended
sterilization
Critical devices Penetration of soft
tissue or bone
Forceps , scalpels,
bone chisels, scalers,
and burs
Heat based
sterilization
Chemical steriliant
Semi-critical devices Comes in contact
with mucus
membranes or minor
skin breaches
Mouth mirror.
Amalgam condensor,
probe, endoscopes.
Chemical steriliant
High degree of
disinfection
Non critical devices Comes in contact
with intact skin
BP cuffs,
thermometer,
stethoscope, X-rays
heads
Intermediate or low
degree of
disinfection.