IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 769
ANALYTICAL STUDY AND IMPLEMENTATION OF DIGITAL
EXCITATION SYSTEM FOR DIESEL GENERATORS
Sreehari S1
, Deepak C R2
1
Student, Electrical and Electronics Department, 2
Student, Computer Science Department,
Amrita Vishwa Vidyapeetham, Tamil Nadu, India, sreeharicybex@gmail.com, deepakcrk@gmail.com
Abstract
This paper aims at the study of DIGITAL EXCITATION SYSTEM [Micro Controller based automatic voltage regulator] employed for
synchronous generators .The main component of the digital excitation system is the Automatic Voltage Regulator. This maintains the
machine terminal voltage in desired reference, which can be varied in order to accomplish different power system requirements .The
digital excitation system is developed from the digital signal processor whichwill capture of variables, performs mathematical
operations and control algorithms and sends the control signals to the actuator. Automatic Voltage regulator (automatic/manual
control), over excitation limiter, Under excitation limité and volts/hertz limiter are included in this digital excitation system. The
exciter is controlled three phase SCR’s bridge
Index Terms: DIGITAL EXCITATION SYSTEM, Automatic Voltage Regulator, SCR Bridge, synchronous
generator,dsPIC30F4012.
-----------------------------------------------------------------------***-----------------------------------------------------------------------
1.INTRODUCTION
Microcontroller based automatic voltage regulator is used to
maintain the terminal voltage of the alternator constant from
no load to full load irrespective of power factor and frequency.
As the terminal voltage decreases depending on machine
reactance and load power factor. A suitable excitation control
is required to keep Alternator terminal voltage
constant.Industrial loads are always fluctuating and controlling
the excitation is difficult by manual operation. So suitable
automatic voltage regulator is required to change excitation at
a faster rate against quick changing loads.
Digital Excitation system panel senses the alternator terminals
voltage, varies the power fed to the alternator field to keep
terminal voltage constant irrespective of load conditions. This
is achieved by thyristor controlled rectifier where triggering
phase angle of the thyristor is varied by fast acting highly
sensitive solid state control circuit which works on close loop
principle.
The field of the alternator is fed from AC exciter and rotating
rectifier. The AC exciter field is controlled from AVR panel.
The AVR panel is having auto and manual channel. They
have separate control circuit, whereas power circuit is
common, hence when auto channel is workingit can be
transformed to manual channel without disturbing the load.
The manual channel is controlled by follow up circuit while
system is operating in auto channel.The follow up unit sense
the output reference of auto channel and gives signal to Digital
Reference Unit (DRU) of the manual channel to maintain the
same reference of auto channel.The power circuit consists of
half controlled full wave thyristor rectifier bridge. The
dsPIC30F4012 will control the firing angle of the thyristors
which control the power fed to the field, overexcited as well as
the under excited condition of the generator by adjusting the
firing angle. So, the software embedded in the microcontroller
helps to maintain fixed terminal voltage, logical operations of
the generator, protection of generator and to maintain the
constant power factor by adjusting the firing angle of the
thyristors.
2. SYNCHRONOUS GENERATOR
2.1 PRINCIPLE OF OPERATION
A synchronous generator is universally employed for the
generation of three phase power at all generating stations. The
largest–sized electrical machines are polyphase synchronous
generators. Under steady-state conditions, the operating speed
of a synchronous machine depends on the frequency
ofarmature currents and the number of field poles and is given
by
Where,
P= number of field poles
N= rotor speed in rpm (Synchronous speed)
F=frequency of armature currents.
120
NP
F 
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 770
Fig.1. Synchronous machine construction and three phase
voltage generated at the terminals of generator
For the successful operation, the rotational speed of the
synchronous machine must synchronize with the frequency of
the energy system that meansthe stator flux and rotor flux
should get tightly bounded and the value of slip should be
zero. For production of torque the relative velocity between
the interacting stator and rotor fields must be zero.
When a synchronous generator is excited with field current
and driven at constant speed, balanced voltage is generated
in the armature winding. If balanced load is connected across
armature winding, balanced armature current at the same
frequency as the e.m.f will flow. Since the frequency of
generated e.m.f is related to the rotor speed, while the speed of
the armature rotating m.m.f is related to the frequency of the
current, it follows that the armature m.m.f rotates
synchronously with the rotor field. An increase in rotor speed
results in a rise in the frequency of e.m.f and current, while the
power factor is determined by the nature of the load.
Fig.2a. Equivalent circuit and phasor diagram for R load
Since the armature mmf rotates at the same speed as the main
field, it produces a corresponding e.m.f in the armature
winding. The effects of armature reaction and armature
winding leakage are considered to produce an equivalent
internal voltage drop across the synchronous reactance Xs,
while the field excitation is accounted for by the open-circuit
armature voltage Ef. The impedance Zs= (R+jXs) is known as
the synchronous impedance of the synchronous generator,
where R is the armature resistance.
For steady-state performance analysis, the per-phase
equivalent circuit shown in Figure 2 is used.
The synchronous generator, under the assumption of constant
synchronous reactance, may be considered as represent able
by an equivalent circuit comprising an ideal
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 771
Fig.2b. Equivalent circuit and phasor diagram for R-L load
Winding in which an e.m.f. Et proportional to the field
excitation is developed, the winding being connected to the
terminals of the machine through a resistance ra and reactance
(Xl + Xa ) = Xs all per phase. This is shown in Fig.2. The
principal characteristics of the synchronous generator will be
obtained qualitatively from this circuit [1, 3, 6].
2.2 GENERATOR LOAD CHARACTERISTICS
On open circuit the terminal voltage V is the same as the open
circuit e.m.f. Et .Suppose a unity-power-factor load be
connected to the machine. The flow of load current produces a
voltage drop IZs in the synchronous impedance and terminal
voltage V is reduced. The terminal voltage is obtained from
the complex summation
t SV E IZ 
Fig.2c. Generator load characteristics
Algebraically this can be written
2 2 2
( )t s rV E I X I  
for non-reactive loads. Since normally r is small
compared with Xs
2 2 2 2
.s tV I X E const  
so that the V/I curve is as given below[6].
2.3GENERATOR EXCITATION FOR CONSTANT
VOLTAGE
Since the e.m.f. Et is proportional to the excitation when the
synchronous reactance is constant, the Eqn.
2 2 2
( cos ) ( s )tE V Ir V in IXs    
can be applied directly to obtain the excitation necessary to
maintain constant output voltage for all loads. All unity-and
lagging power-factor loads will require an increase of
excitation with increase of load current, as a corollary of Fig.3.
Low-leading-power-factor loads, on the other hand, will
require the excitation to be reduced on account of the direct
magnetizing effect of the zero- power-factor component.
Fig.3. Generator excitation for constant voltage
The voltage-regulation of a synchronous generator is the
voltage rise at the terminals when a given load is thrown off,
the excitation and speed remaining constant.The voltage-rise
is clearly the numerical difference between Et and V, where V
is the terminal voltage for a given load and Et is the open-
circuit voltage for the same field excitation.Expressed as a
fraction, the regulation is[6]
( )tE V
perunit
V



3. PROPOSED SCHEME:MICROCONTROLLER
BASED AUTOMATIC VOLTAGE REGULATOR
As the automatic voltage regulator (AVR), which regulates
generator voltage, is a device indispensable for operation, it is
required to have superior reliability in addition to easy
maintenance or repair features. And, recently there exists an
ever-increasing demand for improved system stability through
the excitation control (AVR) in order to prevent decline in
system stability in line with the increase in power system and
power re-routing. At the same time, digital devices as
represented by micro-controllers have been making a
remarkable progress. The digital excitation systems are
achieving, high reliability, easy-operation, and easy
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 772
maintainability plus improved space factor. The main
components of the digital excitation system include:
a] A.C.EXCITATION UNIT
b] ROTATING DIODE or ROTATING RECTIFIER
c] MAIN SYNCHRONOUS GENERATOR
d] MICROCONTROLLER UNIT [dsPIC30F4012]
e] 3-PHASE FULLY BRIDGED THYRISTOR BRIDE
f] ZEROCROSSING DETECTOR
The digital automatic voltage regulator is needed to control the
voltage and the reactive power of the generator. The main
tasks of the regulator are to control the voltage in the steady
state, regulate the voltage under fault conditions and to
facilitate reactive power load-sharing between generators in
parallel operation. The voltage control is used in generators in
island mode operation or in parallel operation with weak
networks. Power factor is controlled in case the generator is
operating in parallel with a strong network. In case of voltage
control, the reactive power sharing between generators can be
controlled additionally by using a reactive droop
compensation method in which the voltage is lowered in the
generator from which the reactive current flows. This lowers
the need for excitation and thus also the reactive current. The
simplest analog automatic voltage-regulator solutions only
control the excitation current in load operation. In more
complex digital regulators, the control functions usually
include power factor control, generator soft start capability,
over-voltage and under-frequency protection, under- and over
excitation current limitation and voltage matching before
synchronizing. The D-AVR supplies and controls the current
in the field winding of the exciter to provide the needed
excitation current to the field winding in the rotor. The
excitation is controlled typically by means of a PID control
algorithm and a diode-bridge rectifier fed switch-mode power
supply or a thyristor-bridge rectifier. The diode bridge rectifier
is a line-commutated converter in which the firing of the
diodes depends only on the line voltage. The Thyristor Bridge
is a self-commutated converter, and the thyristors must be
fired to conduct the current. Typically, Digital automatic
voltage regulators can be supplied by either single or three
phase AC voltage or DC voltage. However, the excitation
current output from the regulator may be limited to a value
lower than the rated value when supplied with single-phase
voltage. A higher current can be achieved with a single-phase
supply by installing an external rectifier and a capacitor on the
D-AVR mounting plate. In no-load operation, the D-AVR
must provide a sufficient field current for the Generator to
produce the rated voltage at the rated speed. From no-load to
full-load operation, the excitation current must be increased to
compensate the effects of the armature reaction. In a generator
short circuit, the D-AVR cannot limit the excitation current
and all the power fed to the AVR is used in excitation. Thus
the excitation current must be limited by other means in order
to reduce the generator short-circuit current. This can be done
by using a separate excitation current limiter. Voltage and
current transformers are needed to measure the instantaneous
values of the main voltage and current to enable the voltage
regulation. As the load current increases, the armature reaction
reduces the air-gap flux and a voltage drop occurs in the
terminals of the generator. The AVR must increase the
excitation current to compensate the armature reaction and the
voltage drops caused by the reactance’s of the machine. The
microcontroller based automatic voltage regulator. In
Microcontroller based Automatic Voltage Regulating system
the terminal voltage from the synchronous generator is fed to
the dsPIC[8]. The dsPIC30F family of devices includes
peripherals that are ideally suited for power control
applications. These peripherals include a high-resolution
PWM module, a 10-bit 2 Msps Analog-to-Digital Converter
module and an Analog Comparator module. The software
embedded in the dsPIC calculates the firing angle and fires the
thyristor bridge in such a way to maintain the terminal voltage
to a referred value. On calculating the firing angle over
excitation limit, under excitation limit, power factor and
synchronized operation of the generator has to be maintained.
Terminal voltage and current is fed to the dsPIC with the help
of PT and CT and the power factor is also fed to the IC with
the help of the timing circuit. Terminal voltage is stepped
down in the range of 0-5v and fed to the IC with the help of
zero crossing detectors [2,4,5,7].
3.1 SYNCHRONISED WORKING OF
GENERATOR
While generator running in parallel with grid the excitation
has to be properly matching may lead to undesirable reactive
loads which may overload alternator an utility factor become
very poor. In case of alternator operating with grid, it has to
run at a constant power factor to meet EB requirement. And
also to maintain the ratio of active and reactive power
irrespective of grid voltage variation to get optimum
utilization. The power factor controller sense the power factor
of the alternator, compare with the reference set and correct
excitation through digital reference unit [DRU].To avoid
oscillation in correction, a dead band setting pot is also given
to adjust the dead band, depending on the fluctuation of the
bus voltage. Two pots are provided to adjust on time of the
rise pulse and on time of lower pulse. Power Factor control by
using separate power factor controller unit which corrects the
excitation parameters through Digital Reference Unit while
operating parallel with grid .Follow up unit is provided to
follow the auto channel and gives corrective signals to the
manual channel. During external fault conditions automatic
change over from auto to manual takes place without
disturbing the load conditions. After rectification of the fault,
change over from manual to auto is possible. That is to change
from manual to auto without disturbing the load conditions;
manually we have to set the reference of auto channel equal to
the manual channel[9].
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 773
3.2 UNDER/OVEREXCITED CONDITION OF
SYNCHRONOUS GENERATOR
During generator operation, it is necessary to observe the
permissible combinations of active and reactive power, which
can be seen from the capability diagram. Limiters employed in
the digital excitation system limits the dangerous operation of
the generators, which can cause damages as overheating, over
fluxing and loss of synchronism. The limiters take the
operating point to a state inside of the limits of machine’s
capability. Limiters can be over excitation limiter, under
excitation limiter, overvoltage limiter, over current limiter,
voltage/frequency limiter although they can include some
others for example the power factor limiter and reactive power
limiter. For this application the over excitation limiter, under
excitation limiter and V/Hz limiter were developed in the
DSP.The under excitation limiter corrects the reactive power
by raising the machine voltage as necessary to ensure that, in
case of an excursion beyond the limit characteristic, the
operating point is returned to that characteristic before the
machine is tripped by the under excitation protection.
The over excitation limiter ensures that, in the overexcited
range, the operating point always keeps within capability
curve section of the generator. In response to system voltage
drops caused by high reactive power requirements, switching
manipulations or faults, the voltage regulator raises the
excitation level so as to keep the generator voltage constant.
The over excitation limiting device acts as a safeguard against
thermal overloading of the rotor.
Fig.4. Possible Design of the Generator Capability Diagram
The over excitation limiter admits excitation current values
between The maximum continuous current and the maximum
excitation Current (field forcing) for a limited period of time
so that the Generator can back up the system in response to
short-time system Voltage dips. The secondary excitation
current limiter (field-forcing limiter), in contrast, has the task
of limiting the excitation current to the maximum permissible
value as quickly as possible. The stator current limiter ensures
the delayed limitation onto working points, within the N-P
range of the generator power diagram. The main task of the
stator current limiter is to prevent the generator stator from
thermical overload, whichcan be caused by a high reactive
power at increased active power.
Fig.5. Possible Design of the Generator stability Diagram
The stator current limiter also permits increased excitation
values for a limited period so that the generator can back up
the system.The over excitation limiter prevents an overheating
in the machine’s field winding. The under excitation limiter
avoids the machine loss of synchronism or avoids an
overheating in the stator end region. The volt/Hertz limiter
receives the terminal voltage and its frequency as input
signals, and protects the synchronous machine and
transformers connected to it damages by conditions of over
flux. The over flux is caused due to a big relation between
voltage and frequency, caused for a suddenly frequency drop.
The control of the power factor is also important for the
stabilized working of generator.While generator running in
parallel with grid or with other alternators the excitation has to
be properly matched. Improper matching may lead to
undesirable reactive loads which may overload the generator
and utility factor becomes very poor. If the power factor is
properly balanced to load power factor for alternator running
in parallel the utilization of alternator is maximum. In case of
alternator operating with grid, it has to run at constant power
factor to meet EB requirement of maintaining the ratio of
active and reactive power irrespective of grid voltage to get
optimum utilization. The timing unit senses the angle between
voltage vector and current vector and this angle is fed to the
dsPIC as interrupts.[10]
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 774
4. FLOWCHART
MAIN
INITIALISE TEMPORARY REGISTERS
INITIALISE PORT B, C, D, E
INITILISE TIMER 1,
2, 3
LOAD FIRING
ANGLE
INITIALISE ADC
REGISTER
INITIALISE ADC RESULT
REGISTER FROM LOWEST
HARDWARE
INTERRUPT
TIMER
2
A
ENABLE RISE INT FOR INT FIRST
POSITION
VOLTAGE FEEDBACK ADC
CURRENT REFERENCE ADC
CURRENT FEEDBACK ADC
VOLTAGE REFERENCE ADC
A
YES
YES
NO
YES
CHECK THE
HIGHER LIMIT
[WITH IN
THEPRESCRIBED
LIMIT] .
NO
INCREMENT THE VALUE
OF FIRING ANGLE
NO
DECREMENT THE VALUE
OF FIRING ANGLE
CHECK
THE
LIMIT=ZER
O .
CHECK THE
LOWER
LIMIT [WITH
IN
THEPRESCRI
BED LIMIT]
.
NEGG
VOLTAG
E REF
-
VOLTAG
E FEED.
POS/0
B
Mai
n
DECREMENT THE
VALUE OF FIRING
ANGLE
CURRENT
REF.
-
CURRENT
FEED.
CHECK THE
LOWER
LIMIT
[WITH IN
THEPRESCRI
BED LIMIT]
.
NEG
NO
POS/0
YES
B
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 775
5. COMPLETE BLOCK DIAGRAM
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 776
CONCLUSIONS
The digital excitation system developed by DSPIC. The
structure utilized for the task execution allowed a good
performance of the system dynamics.
Manual and auto control functions using proportional action
and proportional integral action were enough for obtaining fast
response speed and a zero state stationary error. The over
excitation limiter implemented using a first order dynamics
permits that the limiter operates faster when previous over
excitation levels are high; on the other hand the hysteresis
zone avoids oscillations around the limit point when the
limiter is given back to zero.
The under excitation limiter presets a good performance,
however oscillations around the operation limit zone were
observed, because its structure moved the generator operation
point to the limit line. The operation of the v/hz limiter was
adequate; when is presented a relation between
voltage/frequency on top of 1.05 pu decreased the voltage in
the same proportion that the frequency drops, avoiding an
excessive overflux. Future implementations require to reject
the oscillations presented on the under excitation limiter and
the overshoots in the voltage/frequency limiter. Thus by
employing under excitation as well as over excitation limiters
an efficient and a balanced calculation of the firing angle can
be obtained from the DSPIC 30F 4012nd fed to the thyristor
bridge.
REFERENCES
[1]JB Gupta, “Theory and performance of Electrical
Machines”, S.K. Kataria and Sons publishers, Fourteen
Edition.
[2]Dr. P. S. Bimbra, “Generalized Theory of Electrical
Machines” Khanna publishers, Fifth Edition.
[3]. R.Krishanam, “Electric Motor drives Modelling, analysis
and control”, PHI-India-2009
[4].Orozco, M. L.; Vasquez, H., "Dynamic performance of an
excitation system built in a digital way," Industrial Electronics
and Control Applications, 2005. ICIECA 2005
[5] Juan Dixon (Ph.D.), “three phase controlled rectifiers”,
Department of Electrical EngineeringPontificia Universidad
Católica de ChileVicuña Mackenna 4860 Santiago, CHILE.
[6] Prof. Krishna Vasudevan, Prof. G. SridharaRao,Prof. P.
SasidharaRao” Electrical Machines II”Indian Institute of
Technology Madras.
[7] http://operation of three phase thyristor bridge rectifier
service.eng.uts.edu.
[8]http://microchip.com/dspic30f4012/datasheet.
[9] http://WWW.abb.com/motor&drives.
[10] Dr. Hans-Joachim Herrmann, “Under excitation
Protection”, Power Transmission and Distribution, Siemens,
2007.
BIOGRAPHIES:
Sreehari S received the B.Tech
degree in Electrical & Electronics
Engineering from Calicut
University Institute of Engineering
&Technology, under University of
Calicut Kerala, India, in 2010 and
currently doing M.Tech in Power
Electronics in Amrita
vishwavidyapeetham, Coimbatore,
India. He has published papers in
various international Journals. His research interests
Multilevel inverter structures, renewable energy technologies,
electric drives and control and Excitation systems.
Deepak C R received the B.Tech
degree in computer science from
university of Calicut, Kerala, India, in
2011and currently doing M.Tech in
computer vision and image processing
in Amrita vishwavidyapeetham
university, Coimbatore, India. He has
published papers related to image
processing and electrical engineering
in various international journals. His
research interests include content based video/image retrieval,
document image analysis,digital image watermarking and
computer vision.

More Related Content

What's hot

Direct torque control of induction motor using space vector modulation
Direct torque control of induction motor using space vector modulationDirect torque control of induction motor using space vector modulation
Direct torque control of induction motor using space vector modulationIAEME Publication
 
Analysis and Simulation of Asynchronous Machine Connected with Load Accomplis...
Analysis and Simulation of Asynchronous Machine Connected with Load Accomplis...Analysis and Simulation of Asynchronous Machine Connected with Load Accomplis...
Analysis and Simulation of Asynchronous Machine Connected with Load Accomplis...YogeshIJTSRD
 
Controlling power flow losses in upfc system using adaptive neuro fuzzy contr...
Controlling power flow losses in upfc system using adaptive neuro fuzzy contr...Controlling power flow losses in upfc system using adaptive neuro fuzzy contr...
Controlling power flow losses in upfc system using adaptive neuro fuzzy contr...eSAT Publishing House
 
induction motor protection system seminar report
induction motor protection system seminar reportinduction motor protection system seminar report
induction motor protection system seminar reportdipali karangale
 
speed control of three phase induction motor using IOT
speed control of three phase induction motor using IOTspeed control of three phase induction motor using IOT
speed control of three phase induction motor using IOTswaroop009
 
Induction motor fault diagnosis by motor current signature analysis and neura...
Induction motor fault diagnosis by motor current signature analysis and neura...Induction motor fault diagnosis by motor current signature analysis and neura...
Induction motor fault diagnosis by motor current signature analysis and neura...Editor Jacotech
 
1. direct torque control of induction motor with fuzzy controller a review
1. direct torque control of induction motor with fuzzy controller a review1. direct torque control of induction motor with fuzzy controller a review
1. direct torque control of induction motor with fuzzy controller a reviewMajdi Dadeq
 
Simulation of Direct Torque Control of Induction motor using Space Vector Mo...
Simulation of Direct Torque Control of Induction motor using  Space Vector Mo...Simulation of Direct Torque Control of Induction motor using  Space Vector Mo...
Simulation of Direct Torque Control of Induction motor using Space Vector Mo...IJMER
 
Analysis and control of four quadrant operation of three phase brushless dc (...
Analysis and control of four quadrant operation of three phase brushless dc (...Analysis and control of four quadrant operation of three phase brushless dc (...
Analysis and control of four quadrant operation of three phase brushless dc (...eSAT Publishing House
 
Design of drive for speed control of induction ppt
Design of drive for speed control of induction pptDesign of drive for speed control of induction ppt
Design of drive for speed control of induction pptAvinash Varanasi
 
Stator flux oriented vector control of wind driven self excited induction gen...
Stator flux oriented vector control of wind driven self excited induction gen...Stator flux oriented vector control of wind driven self excited induction gen...
Stator flux oriented vector control of wind driven self excited induction gen...Alexander Decker
 
Updated field oriented control of induction motor.pptx
Updated field oriented control of induction motor.pptxUpdated field oriented control of induction motor.pptx
Updated field oriented control of induction motor.pptxMohit Sharma
 
electronics and robotics
electronics and roboticselectronics and robotics
electronics and roboticsRajat Dhiman
 
Induction motor modelling and applications
Induction motor modelling and applicationsInduction motor modelling and applications
Induction motor modelling and applicationsUmesh Dadde
 
Servo amplifier
Servo amplifierServo amplifier
Servo amplifierFAHAD KHAN
 
Control of variable reluctance machine (8/6) by artificiel intelligence techn...
Control of variable reluctance machine (8/6) by artificiel intelligence techn...Control of variable reluctance machine (8/6) by artificiel intelligence techn...
Control of variable reluctance machine (8/6) by artificiel intelligence techn...IJECEIAES
 

What's hot (18)

Direct torque control of induction motor using space vector modulation
Direct torque control of induction motor using space vector modulationDirect torque control of induction motor using space vector modulation
Direct torque control of induction motor using space vector modulation
 
Analysis and Simulation of Asynchronous Machine Connected with Load Accomplis...
Analysis and Simulation of Asynchronous Machine Connected with Load Accomplis...Analysis and Simulation of Asynchronous Machine Connected with Load Accomplis...
Analysis and Simulation of Asynchronous Machine Connected with Load Accomplis...
 
Controlling power flow losses in upfc system using adaptive neuro fuzzy contr...
Controlling power flow losses in upfc system using adaptive neuro fuzzy contr...Controlling power flow losses in upfc system using adaptive neuro fuzzy contr...
Controlling power flow losses in upfc system using adaptive neuro fuzzy contr...
 
induction motor protection system seminar report
induction motor protection system seminar reportinduction motor protection system seminar report
induction motor protection system seminar report
 
speed control of three phase induction motor using IOT
speed control of three phase induction motor using IOTspeed control of three phase induction motor using IOT
speed control of three phase induction motor using IOT
 
Induction motor fault diagnosis by motor current signature analysis and neura...
Induction motor fault diagnosis by motor current signature analysis and neura...Induction motor fault diagnosis by motor current signature analysis and neura...
Induction motor fault diagnosis by motor current signature analysis and neura...
 
1. direct torque control of induction motor with fuzzy controller a review
1. direct torque control of induction motor with fuzzy controller a review1. direct torque control of induction motor with fuzzy controller a review
1. direct torque control of induction motor with fuzzy controller a review
 
Simulation of Direct Torque Control of Induction motor using Space Vector Mo...
Simulation of Direct Torque Control of Induction motor using  Space Vector Mo...Simulation of Direct Torque Control of Induction motor using  Space Vector Mo...
Simulation of Direct Torque Control of Induction motor using Space Vector Mo...
 
Analysis and control of four quadrant operation of three phase brushless dc (...
Analysis and control of four quadrant operation of three phase brushless dc (...Analysis and control of four quadrant operation of three phase brushless dc (...
Analysis and control of four quadrant operation of three phase brushless dc (...
 
Design of drive for speed control of induction ppt
Design of drive for speed control of induction pptDesign of drive for speed control of induction ppt
Design of drive for speed control of induction ppt
 
Stator flux oriented vector control of wind driven self excited induction gen...
Stator flux oriented vector control of wind driven self excited induction gen...Stator flux oriented vector control of wind driven self excited induction gen...
Stator flux oriented vector control of wind driven self excited induction gen...
 
PROJECT SEMINAR
PROJECT SEMINARPROJECT SEMINAR
PROJECT SEMINAR
 
Updated field oriented control of induction motor.pptx
Updated field oriented control of induction motor.pptxUpdated field oriented control of induction motor.pptx
Updated field oriented control of induction motor.pptx
 
electronics and robotics
electronics and roboticselectronics and robotics
electronics and robotics
 
Induction motor modelling and applications
Induction motor modelling and applicationsInduction motor modelling and applications
Induction motor modelling and applications
 
Servo amplifier
Servo amplifierServo amplifier
Servo amplifier
 
Synchro
SynchroSynchro
Synchro
 
Control of variable reluctance machine (8/6) by artificiel intelligence techn...
Control of variable reluctance machine (8/6) by artificiel intelligence techn...Control of variable reluctance machine (8/6) by artificiel intelligence techn...
Control of variable reluctance machine (8/6) by artificiel intelligence techn...
 

Viewers also liked

User search goal inference and feedback session using fast generalized – fuzz...
User search goal inference and feedback session using fast generalized – fuzz...User search goal inference and feedback session using fast generalized – fuzz...
User search goal inference and feedback session using fast generalized – fuzz...eSAT Publishing House
 
Survey on cloud computing security techniques
Survey on cloud computing security techniquesSurvey on cloud computing security techniques
Survey on cloud computing security techniqueseSAT Publishing House
 
A study on cross layer metrics of wireless mesh network
A study on cross layer metrics of wireless mesh networkA study on cross layer metrics of wireless mesh network
A study on cross layer metrics of wireless mesh networkeSAT Publishing House
 
Web phish detection (an evolutionary approach)
Web phish detection (an evolutionary approach)Web phish detection (an evolutionary approach)
Web phish detection (an evolutionary approach)eSAT Publishing House
 
Overview of wireless network control protocol in smart phone devices
Overview of wireless network control protocol in smart phone devicesOverview of wireless network control protocol in smart phone devices
Overview of wireless network control protocol in smart phone deviceseSAT Publishing House
 
Real time energy data acquisition and alarming system for monitoring power co...
Real time energy data acquisition and alarming system for monitoring power co...Real time energy data acquisition and alarming system for monitoring power co...
Real time energy data acquisition and alarming system for monitoring power co...eSAT Publishing House
 
Performance analysis of various parameters by comparison of conventional pitc...
Performance analysis of various parameters by comparison of conventional pitc...Performance analysis of various parameters by comparison of conventional pitc...
Performance analysis of various parameters by comparison of conventional pitc...eSAT Publishing House
 
Phycoremediation of malachite green and reduction of physico chemical paramet...
Phycoremediation of malachite green and reduction of physico chemical paramet...Phycoremediation of malachite green and reduction of physico chemical paramet...
Phycoremediation of malachite green and reduction of physico chemical paramet...eSAT Publishing House
 
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...eSAT Publishing House
 
Development of pavement management strategies for
Development of pavement management strategies forDevelopment of pavement management strategies for
Development of pavement management strategies foreSAT Publishing House
 
Geopolymer concrete an eco friendly construction material
Geopolymer concrete an eco friendly construction materialGeopolymer concrete an eco friendly construction material
Geopolymer concrete an eco friendly construction materialeSAT Publishing House
 
Novel technique in charactarizing a pv module using
Novel technique in charactarizing a pv module usingNovel technique in charactarizing a pv module using
Novel technique in charactarizing a pv module usingeSAT Publishing House
 
Beam steering in smart antennas by using low complex
Beam steering in smart antennas by using low complexBeam steering in smart antennas by using low complex
Beam steering in smart antennas by using low complexeSAT Publishing House
 
Design evaluation and optimization of steering yoke of an automobile
Design evaluation and optimization of steering yoke of an automobileDesign evaluation and optimization of steering yoke of an automobile
Design evaluation and optimization of steering yoke of an automobileeSAT Publishing House
 
Can fracture mechanics predict damage due disaster of structures
Can fracture mechanics predict damage due disaster of structuresCan fracture mechanics predict damage due disaster of structures
Can fracture mechanics predict damage due disaster of structureseSAT Publishing House
 
Adaptive neurofuzzy system for asthama
Adaptive neurofuzzy system for asthamaAdaptive neurofuzzy system for asthama
Adaptive neurofuzzy system for asthamaeSAT Publishing House
 
Fault detection and diagnosis ingears using wavelet
Fault detection and diagnosis ingears using waveletFault detection and diagnosis ingears using wavelet
Fault detection and diagnosis ingears using waveleteSAT Publishing House
 
The interconnecting mechanism for monitoring regular domestic condition
The interconnecting mechanism for monitoring regular domestic conditionThe interconnecting mechanism for monitoring regular domestic condition
The interconnecting mechanism for monitoring regular domestic conditioneSAT Publishing House
 

Viewers also liked (20)

User search goal inference and feedback session using fast generalized – fuzz...
User search goal inference and feedback session using fast generalized – fuzz...User search goal inference and feedback session using fast generalized – fuzz...
User search goal inference and feedback session using fast generalized – fuzz...
 
Survey on cloud computing security techniques
Survey on cloud computing security techniquesSurvey on cloud computing security techniques
Survey on cloud computing security techniques
 
A study on cross layer metrics of wireless mesh network
A study on cross layer metrics of wireless mesh networkA study on cross layer metrics of wireless mesh network
A study on cross layer metrics of wireless mesh network
 
Web phish detection (an evolutionary approach)
Web phish detection (an evolutionary approach)Web phish detection (an evolutionary approach)
Web phish detection (an evolutionary approach)
 
Overview of wireless network control protocol in smart phone devices
Overview of wireless network control protocol in smart phone devicesOverview of wireless network control protocol in smart phone devices
Overview of wireless network control protocol in smart phone devices
 
Real time energy data acquisition and alarming system for monitoring power co...
Real time energy data acquisition and alarming system for monitoring power co...Real time energy data acquisition and alarming system for monitoring power co...
Real time energy data acquisition and alarming system for monitoring power co...
 
Performance analysis of various parameters by comparison of conventional pitc...
Performance analysis of various parameters by comparison of conventional pitc...Performance analysis of various parameters by comparison of conventional pitc...
Performance analysis of various parameters by comparison of conventional pitc...
 
Phycoremediation of malachite green and reduction of physico chemical paramet...
Phycoremediation of malachite green and reduction of physico chemical paramet...Phycoremediation of malachite green and reduction of physico chemical paramet...
Phycoremediation of malachite green and reduction of physico chemical paramet...
 
Pounding problems in urban areas
Pounding problems in urban areasPounding problems in urban areas
Pounding problems in urban areas
 
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...
 
Development of pavement management strategies for
Development of pavement management strategies forDevelopment of pavement management strategies for
Development of pavement management strategies for
 
Terrestrial gps positioning system
Terrestrial gps positioning systemTerrestrial gps positioning system
Terrestrial gps positioning system
 
Geopolymer concrete an eco friendly construction material
Geopolymer concrete an eco friendly construction materialGeopolymer concrete an eco friendly construction material
Geopolymer concrete an eco friendly construction material
 
Novel technique in charactarizing a pv module using
Novel technique in charactarizing a pv module usingNovel technique in charactarizing a pv module using
Novel technique in charactarizing a pv module using
 
Beam steering in smart antennas by using low complex
Beam steering in smart antennas by using low complexBeam steering in smart antennas by using low complex
Beam steering in smart antennas by using low complex
 
Design evaluation and optimization of steering yoke of an automobile
Design evaluation and optimization of steering yoke of an automobileDesign evaluation and optimization of steering yoke of an automobile
Design evaluation and optimization of steering yoke of an automobile
 
Can fracture mechanics predict damage due disaster of structures
Can fracture mechanics predict damage due disaster of structuresCan fracture mechanics predict damage due disaster of structures
Can fracture mechanics predict damage due disaster of structures
 
Adaptive neurofuzzy system for asthama
Adaptive neurofuzzy system for asthamaAdaptive neurofuzzy system for asthama
Adaptive neurofuzzy system for asthama
 
Fault detection and diagnosis ingears using wavelet
Fault detection and diagnosis ingears using waveletFault detection and diagnosis ingears using wavelet
Fault detection and diagnosis ingears using wavelet
 
The interconnecting mechanism for monitoring regular domestic condition
The interconnecting mechanism for monitoring regular domestic conditionThe interconnecting mechanism for monitoring regular domestic condition
The interconnecting mechanism for monitoring regular domestic condition
 

Similar to Analytical study and implementation of digital excitation system for diesel generators

Modeling & analysis of standalone photovoltaic
Modeling & analysis of standalone photovoltaicModeling & analysis of standalone photovoltaic
Modeling & analysis of standalone photovoltaiceSAT Publishing House
 
Modeling & analysis of standalone photovoltaic system
Modeling & analysis of standalone photovoltaic systemModeling & analysis of standalone photovoltaic system
Modeling & analysis of standalone photovoltaic systemeSAT Journals
 
Design of a wind power generation system using a
Design of a wind power generation system using aDesign of a wind power generation system using a
Design of a wind power generation system using aeSAT Publishing House
 
ANN Approach for Fault Classification in Induction Motors using Current and V...
ANN Approach for Fault Classification in Induction Motors using Current and V...ANN Approach for Fault Classification in Induction Motors using Current and V...
ANN Approach for Fault Classification in Induction Motors using Current and V...IRJET Journal
 
Igbt based on vector control of induction motor drive
Igbt based on vector control of induction motor driveIgbt based on vector control of induction motor drive
Igbt based on vector control of induction motor driveeSAT Journals
 
Igbt based on vector control of induction motor drive
Igbt based on vector control of induction motor driveIgbt based on vector control of induction motor drive
Igbt based on vector control of induction motor driveeSAT Publishing House
 
Performance analysis of a single phase ac voltage controller under induction ...
Performance analysis of a single phase ac voltage controller under induction ...Performance analysis of a single phase ac voltage controller under induction ...
Performance analysis of a single phase ac voltage controller under induction ...eSAT Publishing House
 
Control of inverters to support bidirectional power flow in grid connected sy...
Control of inverters to support bidirectional power flow in grid connected sy...Control of inverters to support bidirectional power flow in grid connected sy...
Control of inverters to support bidirectional power flow in grid connected sy...eSAT Publishing House
 
IRJET- Automated Flow Control in Solid Material Packaging Machines
IRJET- Automated Flow Control in Solid Material Packaging MachinesIRJET- Automated Flow Control in Solid Material Packaging Machines
IRJET- Automated Flow Control in Solid Material Packaging MachinesIRJET Journal
 
Design of a wind power generation system using a permanent magnet synchronous...
Design of a wind power generation system using a permanent magnet synchronous...Design of a wind power generation system using a permanent magnet synchronous...
Design of a wind power generation system using a permanent magnet synchronous...eSAT Journals
 
IRJET- PIC Microcontroller based AC Voltage Stabilizer using Power Electr...
IRJET-  	  PIC Microcontroller based AC Voltage Stabilizer using Power Electr...IRJET-  	  PIC Microcontroller based AC Voltage Stabilizer using Power Electr...
IRJET- PIC Microcontroller based AC Voltage Stabilizer using Power Electr...IRJET Journal
 
Study On Speed Control of DC MOTOR Using Thyristor
Study On Speed Control of DC MOTOR Using ThyristorStudy On Speed Control of DC MOTOR Using Thyristor
Study On Speed Control of DC MOTOR Using ThyristorIRJET Journal
 
Increase productivity and absorption of reactive power for power station with...
Increase productivity and absorption of reactive power for power station with...Increase productivity and absorption of reactive power for power station with...
Increase productivity and absorption of reactive power for power station with...IJITCA Journal
 
IRJET- Vector Control of Three Phase Induction Motor
IRJET- Vector Control of Three Phase Induction MotorIRJET- Vector Control of Three Phase Induction Motor
IRJET- Vector Control of Three Phase Induction MotorIRJET Journal
 
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...IRJET Journal
 
IRJET- Performance Analysis of Induction Motor using IoT
IRJET-  	  Performance Analysis of Induction Motor using IoTIRJET-  	  Performance Analysis of Induction Motor using IoT
IRJET- Performance Analysis of Induction Motor using IoTIRJET Journal
 
USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SU...
USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SU...USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SU...
USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SU...IAEME Publication
 
Investigation in Induction Motor Starting and Speed Control with Variable Fre...
Investigation in Induction Motor Starting and Speed Control with Variable Fre...Investigation in Induction Motor Starting and Speed Control with Variable Fre...
Investigation in Induction Motor Starting and Speed Control with Variable Fre...IRJET Journal
 
The compensatation of unbalanced 3 phase currents in transmission systems on ...
The compensatation of unbalanced 3 phase currents in transmission systems on ...The compensatation of unbalanced 3 phase currents in transmission systems on ...
The compensatation of unbalanced 3 phase currents in transmission systems on ...eSAT Journals
 
The compensatation of unbalanced 3 phase currents in transmission systems on ...
The compensatation of unbalanced 3 phase currents in transmission systems on ...The compensatation of unbalanced 3 phase currents in transmission systems on ...
The compensatation of unbalanced 3 phase currents in transmission systems on ...eSAT Publishing House
 

Similar to Analytical study and implementation of digital excitation system for diesel generators (20)

Modeling & analysis of standalone photovoltaic
Modeling & analysis of standalone photovoltaicModeling & analysis of standalone photovoltaic
Modeling & analysis of standalone photovoltaic
 
Modeling & analysis of standalone photovoltaic system
Modeling & analysis of standalone photovoltaic systemModeling & analysis of standalone photovoltaic system
Modeling & analysis of standalone photovoltaic system
 
Design of a wind power generation system using a
Design of a wind power generation system using aDesign of a wind power generation system using a
Design of a wind power generation system using a
 
ANN Approach for Fault Classification in Induction Motors using Current and V...
ANN Approach for Fault Classification in Induction Motors using Current and V...ANN Approach for Fault Classification in Induction Motors using Current and V...
ANN Approach for Fault Classification in Induction Motors using Current and V...
 
Igbt based on vector control of induction motor drive
Igbt based on vector control of induction motor driveIgbt based on vector control of induction motor drive
Igbt based on vector control of induction motor drive
 
Igbt based on vector control of induction motor drive
Igbt based on vector control of induction motor driveIgbt based on vector control of induction motor drive
Igbt based on vector control of induction motor drive
 
Performance analysis of a single phase ac voltage controller under induction ...
Performance analysis of a single phase ac voltage controller under induction ...Performance analysis of a single phase ac voltage controller under induction ...
Performance analysis of a single phase ac voltage controller under induction ...
 
Control of inverters to support bidirectional power flow in grid connected sy...
Control of inverters to support bidirectional power flow in grid connected sy...Control of inverters to support bidirectional power flow in grid connected sy...
Control of inverters to support bidirectional power flow in grid connected sy...
 
IRJET- Automated Flow Control in Solid Material Packaging Machines
IRJET- Automated Flow Control in Solid Material Packaging MachinesIRJET- Automated Flow Control in Solid Material Packaging Machines
IRJET- Automated Flow Control in Solid Material Packaging Machines
 
Design of a wind power generation system using a permanent magnet synchronous...
Design of a wind power generation system using a permanent magnet synchronous...Design of a wind power generation system using a permanent magnet synchronous...
Design of a wind power generation system using a permanent magnet synchronous...
 
IRJET- PIC Microcontroller based AC Voltage Stabilizer using Power Electr...
IRJET-  	  PIC Microcontroller based AC Voltage Stabilizer using Power Electr...IRJET-  	  PIC Microcontroller based AC Voltage Stabilizer using Power Electr...
IRJET- PIC Microcontroller based AC Voltage Stabilizer using Power Electr...
 
Study On Speed Control of DC MOTOR Using Thyristor
Study On Speed Control of DC MOTOR Using ThyristorStudy On Speed Control of DC MOTOR Using Thyristor
Study On Speed Control of DC MOTOR Using Thyristor
 
Increase productivity and absorption of reactive power for power station with...
Increase productivity and absorption of reactive power for power station with...Increase productivity and absorption of reactive power for power station with...
Increase productivity and absorption of reactive power for power station with...
 
IRJET- Vector Control of Three Phase Induction Motor
IRJET- Vector Control of Three Phase Induction MotorIRJET- Vector Control of Three Phase Induction Motor
IRJET- Vector Control of Three Phase Induction Motor
 
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
 
IRJET- Performance Analysis of Induction Motor using IoT
IRJET-  	  Performance Analysis of Induction Motor using IoTIRJET-  	  Performance Analysis of Induction Motor using IoT
IRJET- Performance Analysis of Induction Motor using IoT
 
USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SU...
USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SU...USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SU...
USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SU...
 
Investigation in Induction Motor Starting and Speed Control with Variable Fre...
Investigation in Induction Motor Starting and Speed Control with Variable Fre...Investigation in Induction Motor Starting and Speed Control with Variable Fre...
Investigation in Induction Motor Starting and Speed Control with Variable Fre...
 
The compensatation of unbalanced 3 phase currents in transmission systems on ...
The compensatation of unbalanced 3 phase currents in transmission systems on ...The compensatation of unbalanced 3 phase currents in transmission systems on ...
The compensatation of unbalanced 3 phase currents in transmission systems on ...
 
The compensatation of unbalanced 3 phase currents in transmission systems on ...
The compensatation of unbalanced 3 phase currents in transmission systems on ...The compensatation of unbalanced 3 phase currents in transmission systems on ...
The compensatation of unbalanced 3 phase currents in transmission systems on ...
 

More from eSAT Publishing House

Likely impacts of hudhud on the environment of visakhapatnam
Likely impacts of hudhud on the environment of visakhapatnamLikely impacts of hudhud on the environment of visakhapatnam
Likely impacts of hudhud on the environment of visakhapatnameSAT Publishing House
 
Impact of flood disaster in a drought prone area – case study of alampur vill...
Impact of flood disaster in a drought prone area – case study of alampur vill...Impact of flood disaster in a drought prone area – case study of alampur vill...
Impact of flood disaster in a drought prone area – case study of alampur vill...eSAT Publishing House
 
Hudhud cyclone – a severe disaster in visakhapatnam
Hudhud cyclone – a severe disaster in visakhapatnamHudhud cyclone – a severe disaster in visakhapatnam
Hudhud cyclone – a severe disaster in visakhapatnameSAT Publishing House
 
Groundwater investigation using geophysical methods a case study of pydibhim...
Groundwater investigation using geophysical methods  a case study of pydibhim...Groundwater investigation using geophysical methods  a case study of pydibhim...
Groundwater investigation using geophysical methods a case study of pydibhim...eSAT Publishing House
 
Flood related disasters concerned to urban flooding in bangalore, india
Flood related disasters concerned to urban flooding in bangalore, indiaFlood related disasters concerned to urban flooding in bangalore, india
Flood related disasters concerned to urban flooding in bangalore, indiaeSAT Publishing House
 
Enhancing post disaster recovery by optimal infrastructure capacity building
Enhancing post disaster recovery by optimal infrastructure capacity buildingEnhancing post disaster recovery by optimal infrastructure capacity building
Enhancing post disaster recovery by optimal infrastructure capacity buildingeSAT Publishing House
 
Effect of lintel and lintel band on the global performance of reinforced conc...
Effect of lintel and lintel band on the global performance of reinforced conc...Effect of lintel and lintel band on the global performance of reinforced conc...
Effect of lintel and lintel band on the global performance of reinforced conc...eSAT Publishing House
 
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...eSAT Publishing House
 
Wind damage to buildings, infrastrucuture and landscape elements along the be...
Wind damage to buildings, infrastrucuture and landscape elements along the be...Wind damage to buildings, infrastrucuture and landscape elements along the be...
Wind damage to buildings, infrastrucuture and landscape elements along the be...eSAT Publishing House
 
Shear strength of rc deep beam panels – a review
Shear strength of rc deep beam panels – a reviewShear strength of rc deep beam panels – a review
Shear strength of rc deep beam panels – a revieweSAT Publishing House
 
Role of voluntary teams of professional engineers in dissater management – ex...
Role of voluntary teams of professional engineers in dissater management – ex...Role of voluntary teams of professional engineers in dissater management – ex...
Role of voluntary teams of professional engineers in dissater management – ex...eSAT Publishing House
 
Risk analysis and environmental hazard management
Risk analysis and environmental hazard managementRisk analysis and environmental hazard management
Risk analysis and environmental hazard managementeSAT Publishing House
 
Review study on performance of seismically tested repaired shear walls
Review study on performance of seismically tested repaired shear wallsReview study on performance of seismically tested repaired shear walls
Review study on performance of seismically tested repaired shear wallseSAT Publishing House
 
Monitoring and assessment of air quality with reference to dust particles (pm...
Monitoring and assessment of air quality with reference to dust particles (pm...Monitoring and assessment of air quality with reference to dust particles (pm...
Monitoring and assessment of air quality with reference to dust particles (pm...eSAT Publishing House
 
Low cost wireless sensor networks and smartphone applications for disaster ma...
Low cost wireless sensor networks and smartphone applications for disaster ma...Low cost wireless sensor networks and smartphone applications for disaster ma...
Low cost wireless sensor networks and smartphone applications for disaster ma...eSAT Publishing House
 
Coastal zones – seismic vulnerability an analysis from east coast of india
Coastal zones – seismic vulnerability an analysis from east coast of indiaCoastal zones – seismic vulnerability an analysis from east coast of india
Coastal zones – seismic vulnerability an analysis from east coast of indiaeSAT Publishing House
 
Assessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildingsAssessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildingseSAT Publishing House
 
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...eSAT Publishing House
 
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...eSAT Publishing House
 
Disaster recovery sustainable housing
Disaster recovery sustainable housingDisaster recovery sustainable housing
Disaster recovery sustainable housingeSAT Publishing House
 

More from eSAT Publishing House (20)

Likely impacts of hudhud on the environment of visakhapatnam
Likely impacts of hudhud on the environment of visakhapatnamLikely impacts of hudhud on the environment of visakhapatnam
Likely impacts of hudhud on the environment of visakhapatnam
 
Impact of flood disaster in a drought prone area – case study of alampur vill...
Impact of flood disaster in a drought prone area – case study of alampur vill...Impact of flood disaster in a drought prone area – case study of alampur vill...
Impact of flood disaster in a drought prone area – case study of alampur vill...
 
Hudhud cyclone – a severe disaster in visakhapatnam
Hudhud cyclone – a severe disaster in visakhapatnamHudhud cyclone – a severe disaster in visakhapatnam
Hudhud cyclone – a severe disaster in visakhapatnam
 
Groundwater investigation using geophysical methods a case study of pydibhim...
Groundwater investigation using geophysical methods  a case study of pydibhim...Groundwater investigation using geophysical methods  a case study of pydibhim...
Groundwater investigation using geophysical methods a case study of pydibhim...
 
Flood related disasters concerned to urban flooding in bangalore, india
Flood related disasters concerned to urban flooding in bangalore, indiaFlood related disasters concerned to urban flooding in bangalore, india
Flood related disasters concerned to urban flooding in bangalore, india
 
Enhancing post disaster recovery by optimal infrastructure capacity building
Enhancing post disaster recovery by optimal infrastructure capacity buildingEnhancing post disaster recovery by optimal infrastructure capacity building
Enhancing post disaster recovery by optimal infrastructure capacity building
 
Effect of lintel and lintel band on the global performance of reinforced conc...
Effect of lintel and lintel band on the global performance of reinforced conc...Effect of lintel and lintel band on the global performance of reinforced conc...
Effect of lintel and lintel band on the global performance of reinforced conc...
 
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
 
Wind damage to buildings, infrastrucuture and landscape elements along the be...
Wind damage to buildings, infrastrucuture and landscape elements along the be...Wind damage to buildings, infrastrucuture and landscape elements along the be...
Wind damage to buildings, infrastrucuture and landscape elements along the be...
 
Shear strength of rc deep beam panels – a review
Shear strength of rc deep beam panels – a reviewShear strength of rc deep beam panels – a review
Shear strength of rc deep beam panels – a review
 
Role of voluntary teams of professional engineers in dissater management – ex...
Role of voluntary teams of professional engineers in dissater management – ex...Role of voluntary teams of professional engineers in dissater management – ex...
Role of voluntary teams of professional engineers in dissater management – ex...
 
Risk analysis and environmental hazard management
Risk analysis and environmental hazard managementRisk analysis and environmental hazard management
Risk analysis and environmental hazard management
 
Review study on performance of seismically tested repaired shear walls
Review study on performance of seismically tested repaired shear wallsReview study on performance of seismically tested repaired shear walls
Review study on performance of seismically tested repaired shear walls
 
Monitoring and assessment of air quality with reference to dust particles (pm...
Monitoring and assessment of air quality with reference to dust particles (pm...Monitoring and assessment of air quality with reference to dust particles (pm...
Monitoring and assessment of air quality with reference to dust particles (pm...
 
Low cost wireless sensor networks and smartphone applications for disaster ma...
Low cost wireless sensor networks and smartphone applications for disaster ma...Low cost wireless sensor networks and smartphone applications for disaster ma...
Low cost wireless sensor networks and smartphone applications for disaster ma...
 
Coastal zones – seismic vulnerability an analysis from east coast of india
Coastal zones – seismic vulnerability an analysis from east coast of indiaCoastal zones – seismic vulnerability an analysis from east coast of india
Coastal zones – seismic vulnerability an analysis from east coast of india
 
Assessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildingsAssessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildings
 
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
 
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
 
Disaster recovery sustainable housing
Disaster recovery sustainable housingDisaster recovery sustainable housing
Disaster recovery sustainable housing
 

Recently uploaded

Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...VICTOR MAESTRE RAMIREZ
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...srsj9000
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfAsst.prof M.Gokilavani
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx959SahilShah
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
Electronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfElectronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfme23b1001
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024Mark Billinghurst
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
Introduction to Microprocesso programming and interfacing.pptx
Introduction to Microprocesso programming and interfacing.pptxIntroduction to Microprocesso programming and interfacing.pptx
Introduction to Microprocesso programming and interfacing.pptxvipinkmenon1
 
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2RajaP95
 
Concrete Mix Design - IS 10262-2019 - .pptx
Concrete Mix Design - IS 10262-2019 - .pptxConcrete Mix Design - IS 10262-2019 - .pptx
Concrete Mix Design - IS 10262-2019 - .pptxKartikeyaDwivedi3
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineeringmalavadedarshan25
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 

Recently uploaded (20)

young call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Serviceyoung call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Service
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
Electronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdfElectronically Controlled suspensions system .pdf
Electronically Controlled suspensions system .pdf
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
Introduction to Microprocesso programming and interfacing.pptx
Introduction to Microprocesso programming and interfacing.pptxIntroduction to Microprocesso programming and interfacing.pptx
Introduction to Microprocesso programming and interfacing.pptx
 
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
Concrete Mix Design - IS 10262-2019 - .pptx
Concrete Mix Design - IS 10262-2019 - .pptxConcrete Mix Design - IS 10262-2019 - .pptx
Concrete Mix Design - IS 10262-2019 - .pptx
 
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineering
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
 

Analytical study and implementation of digital excitation system for diesel generators

  • 1. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 769 ANALYTICAL STUDY AND IMPLEMENTATION OF DIGITAL EXCITATION SYSTEM FOR DIESEL GENERATORS Sreehari S1 , Deepak C R2 1 Student, Electrical and Electronics Department, 2 Student, Computer Science Department, Amrita Vishwa Vidyapeetham, Tamil Nadu, India, sreeharicybex@gmail.com, deepakcrk@gmail.com Abstract This paper aims at the study of DIGITAL EXCITATION SYSTEM [Micro Controller based automatic voltage regulator] employed for synchronous generators .The main component of the digital excitation system is the Automatic Voltage Regulator. This maintains the machine terminal voltage in desired reference, which can be varied in order to accomplish different power system requirements .The digital excitation system is developed from the digital signal processor whichwill capture of variables, performs mathematical operations and control algorithms and sends the control signals to the actuator. Automatic Voltage regulator (automatic/manual control), over excitation limiter, Under excitation limité and volts/hertz limiter are included in this digital excitation system. The exciter is controlled three phase SCR’s bridge Index Terms: DIGITAL EXCITATION SYSTEM, Automatic Voltage Regulator, SCR Bridge, synchronous generator,dsPIC30F4012. -----------------------------------------------------------------------***----------------------------------------------------------------------- 1.INTRODUCTION Microcontroller based automatic voltage regulator is used to maintain the terminal voltage of the alternator constant from no load to full load irrespective of power factor and frequency. As the terminal voltage decreases depending on machine reactance and load power factor. A suitable excitation control is required to keep Alternator terminal voltage constant.Industrial loads are always fluctuating and controlling the excitation is difficult by manual operation. So suitable automatic voltage regulator is required to change excitation at a faster rate against quick changing loads. Digital Excitation system panel senses the alternator terminals voltage, varies the power fed to the alternator field to keep terminal voltage constant irrespective of load conditions. This is achieved by thyristor controlled rectifier where triggering phase angle of the thyristor is varied by fast acting highly sensitive solid state control circuit which works on close loop principle. The field of the alternator is fed from AC exciter and rotating rectifier. The AC exciter field is controlled from AVR panel. The AVR panel is having auto and manual channel. They have separate control circuit, whereas power circuit is common, hence when auto channel is workingit can be transformed to manual channel without disturbing the load. The manual channel is controlled by follow up circuit while system is operating in auto channel.The follow up unit sense the output reference of auto channel and gives signal to Digital Reference Unit (DRU) of the manual channel to maintain the same reference of auto channel.The power circuit consists of half controlled full wave thyristor rectifier bridge. The dsPIC30F4012 will control the firing angle of the thyristors which control the power fed to the field, overexcited as well as the under excited condition of the generator by adjusting the firing angle. So, the software embedded in the microcontroller helps to maintain fixed terminal voltage, logical operations of the generator, protection of generator and to maintain the constant power factor by adjusting the firing angle of the thyristors. 2. SYNCHRONOUS GENERATOR 2.1 PRINCIPLE OF OPERATION A synchronous generator is universally employed for the generation of three phase power at all generating stations. The largest–sized electrical machines are polyphase synchronous generators. Under steady-state conditions, the operating speed of a synchronous machine depends on the frequency ofarmature currents and the number of field poles and is given by Where, P= number of field poles N= rotor speed in rpm (Synchronous speed) F=frequency of armature currents. 120 NP F 
  • 2. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 770 Fig.1. Synchronous machine construction and three phase voltage generated at the terminals of generator For the successful operation, the rotational speed of the synchronous machine must synchronize with the frequency of the energy system that meansthe stator flux and rotor flux should get tightly bounded and the value of slip should be zero. For production of torque the relative velocity between the interacting stator and rotor fields must be zero. When a synchronous generator is excited with field current and driven at constant speed, balanced voltage is generated in the armature winding. If balanced load is connected across armature winding, balanced armature current at the same frequency as the e.m.f will flow. Since the frequency of generated e.m.f is related to the rotor speed, while the speed of the armature rotating m.m.f is related to the frequency of the current, it follows that the armature m.m.f rotates synchronously with the rotor field. An increase in rotor speed results in a rise in the frequency of e.m.f and current, while the power factor is determined by the nature of the load. Fig.2a. Equivalent circuit and phasor diagram for R load Since the armature mmf rotates at the same speed as the main field, it produces a corresponding e.m.f in the armature winding. The effects of armature reaction and armature winding leakage are considered to produce an equivalent internal voltage drop across the synchronous reactance Xs, while the field excitation is accounted for by the open-circuit armature voltage Ef. The impedance Zs= (R+jXs) is known as the synchronous impedance of the synchronous generator, where R is the armature resistance. For steady-state performance analysis, the per-phase equivalent circuit shown in Figure 2 is used. The synchronous generator, under the assumption of constant synchronous reactance, may be considered as represent able by an equivalent circuit comprising an ideal
  • 3. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 771 Fig.2b. Equivalent circuit and phasor diagram for R-L load Winding in which an e.m.f. Et proportional to the field excitation is developed, the winding being connected to the terminals of the machine through a resistance ra and reactance (Xl + Xa ) = Xs all per phase. This is shown in Fig.2. The principal characteristics of the synchronous generator will be obtained qualitatively from this circuit [1, 3, 6]. 2.2 GENERATOR LOAD CHARACTERISTICS On open circuit the terminal voltage V is the same as the open circuit e.m.f. Et .Suppose a unity-power-factor load be connected to the machine. The flow of load current produces a voltage drop IZs in the synchronous impedance and terminal voltage V is reduced. The terminal voltage is obtained from the complex summation t SV E IZ  Fig.2c. Generator load characteristics Algebraically this can be written 2 2 2 ( )t s rV E I X I   for non-reactive loads. Since normally r is small compared with Xs 2 2 2 2 .s tV I X E const   so that the V/I curve is as given below[6]. 2.3GENERATOR EXCITATION FOR CONSTANT VOLTAGE Since the e.m.f. Et is proportional to the excitation when the synchronous reactance is constant, the Eqn. 2 2 2 ( cos ) ( s )tE V Ir V in IXs     can be applied directly to obtain the excitation necessary to maintain constant output voltage for all loads. All unity-and lagging power-factor loads will require an increase of excitation with increase of load current, as a corollary of Fig.3. Low-leading-power-factor loads, on the other hand, will require the excitation to be reduced on account of the direct magnetizing effect of the zero- power-factor component. Fig.3. Generator excitation for constant voltage The voltage-regulation of a synchronous generator is the voltage rise at the terminals when a given load is thrown off, the excitation and speed remaining constant.The voltage-rise is clearly the numerical difference between Et and V, where V is the terminal voltage for a given load and Et is the open- circuit voltage for the same field excitation.Expressed as a fraction, the regulation is[6] ( )tE V perunit V    3. PROPOSED SCHEME:MICROCONTROLLER BASED AUTOMATIC VOLTAGE REGULATOR As the automatic voltage regulator (AVR), which regulates generator voltage, is a device indispensable for operation, it is required to have superior reliability in addition to easy maintenance or repair features. And, recently there exists an ever-increasing demand for improved system stability through the excitation control (AVR) in order to prevent decline in system stability in line with the increase in power system and power re-routing. At the same time, digital devices as represented by micro-controllers have been making a remarkable progress. The digital excitation systems are achieving, high reliability, easy-operation, and easy
  • 4. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 772 maintainability plus improved space factor. The main components of the digital excitation system include: a] A.C.EXCITATION UNIT b] ROTATING DIODE or ROTATING RECTIFIER c] MAIN SYNCHRONOUS GENERATOR d] MICROCONTROLLER UNIT [dsPIC30F4012] e] 3-PHASE FULLY BRIDGED THYRISTOR BRIDE f] ZEROCROSSING DETECTOR The digital automatic voltage regulator is needed to control the voltage and the reactive power of the generator. The main tasks of the regulator are to control the voltage in the steady state, regulate the voltage under fault conditions and to facilitate reactive power load-sharing between generators in parallel operation. The voltage control is used in generators in island mode operation or in parallel operation with weak networks. Power factor is controlled in case the generator is operating in parallel with a strong network. In case of voltage control, the reactive power sharing between generators can be controlled additionally by using a reactive droop compensation method in which the voltage is lowered in the generator from which the reactive current flows. This lowers the need for excitation and thus also the reactive current. The simplest analog automatic voltage-regulator solutions only control the excitation current in load operation. In more complex digital regulators, the control functions usually include power factor control, generator soft start capability, over-voltage and under-frequency protection, under- and over excitation current limitation and voltage matching before synchronizing. The D-AVR supplies and controls the current in the field winding of the exciter to provide the needed excitation current to the field winding in the rotor. The excitation is controlled typically by means of a PID control algorithm and a diode-bridge rectifier fed switch-mode power supply or a thyristor-bridge rectifier. The diode bridge rectifier is a line-commutated converter in which the firing of the diodes depends only on the line voltage. The Thyristor Bridge is a self-commutated converter, and the thyristors must be fired to conduct the current. Typically, Digital automatic voltage regulators can be supplied by either single or three phase AC voltage or DC voltage. However, the excitation current output from the regulator may be limited to a value lower than the rated value when supplied with single-phase voltage. A higher current can be achieved with a single-phase supply by installing an external rectifier and a capacitor on the D-AVR mounting plate. In no-load operation, the D-AVR must provide a sufficient field current for the Generator to produce the rated voltage at the rated speed. From no-load to full-load operation, the excitation current must be increased to compensate the effects of the armature reaction. In a generator short circuit, the D-AVR cannot limit the excitation current and all the power fed to the AVR is used in excitation. Thus the excitation current must be limited by other means in order to reduce the generator short-circuit current. This can be done by using a separate excitation current limiter. Voltage and current transformers are needed to measure the instantaneous values of the main voltage and current to enable the voltage regulation. As the load current increases, the armature reaction reduces the air-gap flux and a voltage drop occurs in the terminals of the generator. The AVR must increase the excitation current to compensate the armature reaction and the voltage drops caused by the reactance’s of the machine. The microcontroller based automatic voltage regulator. In Microcontroller based Automatic Voltage Regulating system the terminal voltage from the synchronous generator is fed to the dsPIC[8]. The dsPIC30F family of devices includes peripherals that are ideally suited for power control applications. These peripherals include a high-resolution PWM module, a 10-bit 2 Msps Analog-to-Digital Converter module and an Analog Comparator module. The software embedded in the dsPIC calculates the firing angle and fires the thyristor bridge in such a way to maintain the terminal voltage to a referred value. On calculating the firing angle over excitation limit, under excitation limit, power factor and synchronized operation of the generator has to be maintained. Terminal voltage and current is fed to the dsPIC with the help of PT and CT and the power factor is also fed to the IC with the help of the timing circuit. Terminal voltage is stepped down in the range of 0-5v and fed to the IC with the help of zero crossing detectors [2,4,5,7]. 3.1 SYNCHRONISED WORKING OF GENERATOR While generator running in parallel with grid the excitation has to be properly matching may lead to undesirable reactive loads which may overload alternator an utility factor become very poor. In case of alternator operating with grid, it has to run at a constant power factor to meet EB requirement. And also to maintain the ratio of active and reactive power irrespective of grid voltage variation to get optimum utilization. The power factor controller sense the power factor of the alternator, compare with the reference set and correct excitation through digital reference unit [DRU].To avoid oscillation in correction, a dead band setting pot is also given to adjust the dead band, depending on the fluctuation of the bus voltage. Two pots are provided to adjust on time of the rise pulse and on time of lower pulse. Power Factor control by using separate power factor controller unit which corrects the excitation parameters through Digital Reference Unit while operating parallel with grid .Follow up unit is provided to follow the auto channel and gives corrective signals to the manual channel. During external fault conditions automatic change over from auto to manual takes place without disturbing the load conditions. After rectification of the fault, change over from manual to auto is possible. That is to change from manual to auto without disturbing the load conditions; manually we have to set the reference of auto channel equal to the manual channel[9].
  • 5. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 773 3.2 UNDER/OVEREXCITED CONDITION OF SYNCHRONOUS GENERATOR During generator operation, it is necessary to observe the permissible combinations of active and reactive power, which can be seen from the capability diagram. Limiters employed in the digital excitation system limits the dangerous operation of the generators, which can cause damages as overheating, over fluxing and loss of synchronism. The limiters take the operating point to a state inside of the limits of machine’s capability. Limiters can be over excitation limiter, under excitation limiter, overvoltage limiter, over current limiter, voltage/frequency limiter although they can include some others for example the power factor limiter and reactive power limiter. For this application the over excitation limiter, under excitation limiter and V/Hz limiter were developed in the DSP.The under excitation limiter corrects the reactive power by raising the machine voltage as necessary to ensure that, in case of an excursion beyond the limit characteristic, the operating point is returned to that characteristic before the machine is tripped by the under excitation protection. The over excitation limiter ensures that, in the overexcited range, the operating point always keeps within capability curve section of the generator. In response to system voltage drops caused by high reactive power requirements, switching manipulations or faults, the voltage regulator raises the excitation level so as to keep the generator voltage constant. The over excitation limiting device acts as a safeguard against thermal overloading of the rotor. Fig.4. Possible Design of the Generator Capability Diagram The over excitation limiter admits excitation current values between The maximum continuous current and the maximum excitation Current (field forcing) for a limited period of time so that the Generator can back up the system in response to short-time system Voltage dips. The secondary excitation current limiter (field-forcing limiter), in contrast, has the task of limiting the excitation current to the maximum permissible value as quickly as possible. The stator current limiter ensures the delayed limitation onto working points, within the N-P range of the generator power diagram. The main task of the stator current limiter is to prevent the generator stator from thermical overload, whichcan be caused by a high reactive power at increased active power. Fig.5. Possible Design of the Generator stability Diagram The stator current limiter also permits increased excitation values for a limited period so that the generator can back up the system.The over excitation limiter prevents an overheating in the machine’s field winding. The under excitation limiter avoids the machine loss of synchronism or avoids an overheating in the stator end region. The volt/Hertz limiter receives the terminal voltage and its frequency as input signals, and protects the synchronous machine and transformers connected to it damages by conditions of over flux. The over flux is caused due to a big relation between voltage and frequency, caused for a suddenly frequency drop. The control of the power factor is also important for the stabilized working of generator.While generator running in parallel with grid or with other alternators the excitation has to be properly matched. Improper matching may lead to undesirable reactive loads which may overload the generator and utility factor becomes very poor. If the power factor is properly balanced to load power factor for alternator running in parallel the utilization of alternator is maximum. In case of alternator operating with grid, it has to run at constant power factor to meet EB requirement of maintaining the ratio of active and reactive power irrespective of grid voltage to get optimum utilization. The timing unit senses the angle between voltage vector and current vector and this angle is fed to the dsPIC as interrupts.[10]
  • 6. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 774 4. FLOWCHART MAIN INITIALISE TEMPORARY REGISTERS INITIALISE PORT B, C, D, E INITILISE TIMER 1, 2, 3 LOAD FIRING ANGLE INITIALISE ADC REGISTER INITIALISE ADC RESULT REGISTER FROM LOWEST HARDWARE INTERRUPT TIMER 2 A ENABLE RISE INT FOR INT FIRST POSITION VOLTAGE FEEDBACK ADC CURRENT REFERENCE ADC CURRENT FEEDBACK ADC VOLTAGE REFERENCE ADC A YES YES NO YES CHECK THE HIGHER LIMIT [WITH IN THEPRESCRIBED LIMIT] . NO INCREMENT THE VALUE OF FIRING ANGLE NO DECREMENT THE VALUE OF FIRING ANGLE CHECK THE LIMIT=ZER O . CHECK THE LOWER LIMIT [WITH IN THEPRESCRI BED LIMIT] . NEGG VOLTAG E REF - VOLTAG E FEED. POS/0 B Mai n DECREMENT THE VALUE OF FIRING ANGLE CURRENT REF. - CURRENT FEED. CHECK THE LOWER LIMIT [WITH IN THEPRESCRI BED LIMIT] . NEG NO POS/0 YES B
  • 7. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 775 5. COMPLETE BLOCK DIAGRAM
  • 8. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 02 Issue: 05 | May-2013, Available @ http://www.ijret.org 776 CONCLUSIONS The digital excitation system developed by DSPIC. The structure utilized for the task execution allowed a good performance of the system dynamics. Manual and auto control functions using proportional action and proportional integral action were enough for obtaining fast response speed and a zero state stationary error. The over excitation limiter implemented using a first order dynamics permits that the limiter operates faster when previous over excitation levels are high; on the other hand the hysteresis zone avoids oscillations around the limit point when the limiter is given back to zero. The under excitation limiter presets a good performance, however oscillations around the operation limit zone were observed, because its structure moved the generator operation point to the limit line. The operation of the v/hz limiter was adequate; when is presented a relation between voltage/frequency on top of 1.05 pu decreased the voltage in the same proportion that the frequency drops, avoiding an excessive overflux. Future implementations require to reject the oscillations presented on the under excitation limiter and the overshoots in the voltage/frequency limiter. Thus by employing under excitation as well as over excitation limiters an efficient and a balanced calculation of the firing angle can be obtained from the DSPIC 30F 4012nd fed to the thyristor bridge. REFERENCES [1]JB Gupta, “Theory and performance of Electrical Machines”, S.K. Kataria and Sons publishers, Fourteen Edition. [2]Dr. P. S. Bimbra, “Generalized Theory of Electrical Machines” Khanna publishers, Fifth Edition. [3]. R.Krishanam, “Electric Motor drives Modelling, analysis and control”, PHI-India-2009 [4].Orozco, M. L.; Vasquez, H., "Dynamic performance of an excitation system built in a digital way," Industrial Electronics and Control Applications, 2005. ICIECA 2005 [5] Juan Dixon (Ph.D.), “three phase controlled rectifiers”, Department of Electrical EngineeringPontificia Universidad Católica de ChileVicuña Mackenna 4860 Santiago, CHILE. [6] Prof. Krishna Vasudevan, Prof. G. SridharaRao,Prof. P. SasidharaRao” Electrical Machines II”Indian Institute of Technology Madras. [7] http://operation of three phase thyristor bridge rectifier service.eng.uts.edu. [8]http://microchip.com/dspic30f4012/datasheet. [9] http://WWW.abb.com/motor&drives. [10] Dr. Hans-Joachim Herrmann, “Under excitation Protection”, Power Transmission and Distribution, Siemens, 2007. BIOGRAPHIES: Sreehari S received the B.Tech degree in Electrical & Electronics Engineering from Calicut University Institute of Engineering &Technology, under University of Calicut Kerala, India, in 2010 and currently doing M.Tech in Power Electronics in Amrita vishwavidyapeetham, Coimbatore, India. He has published papers in various international Journals. His research interests Multilevel inverter structures, renewable energy technologies, electric drives and control and Excitation systems. Deepak C R received the B.Tech degree in computer science from university of Calicut, Kerala, India, in 2011and currently doing M.Tech in computer vision and image processing in Amrita vishwavidyapeetham university, Coimbatore, India. He has published papers related to image processing and electrical engineering in various international journals. His research interests include content based video/image retrieval, document image analysis,digital image watermarking and computer vision.