The GHR heated regulator is designed to prevent condensation of gas samples during pressure reduction in gas analytical systems. It features a self-limiting block heater and two-stage heating technology to ensure heat transfer throughout the pressure reduction process. This prevents issues like regulator freeze-ups and preserves sample integrity, reducing downtime and maintenance costs for gas analyzers.
1. Genie GHR
Heated Regulator
An Analytically Correct single stage pressure
regulator with robust heat transfer technology
specifically designed for gas analytical systems
The Model GHR Genie Heated Pressure Regulator is a single stage
pressure regulator with a self-limiting block heater designed
specifically for use in gas analyser sample conditioning systems.
KEYBENEFITS
Prevents Condensation During Pressure Reduction
gas, preserving sample integrity
• Reduces regulator freeze-ups
• Horizontal or vertical mounting
• Minimises analyser down time and
connection and prevents condensation from occurring during the
pressure
cooling
maintenance cost
• Self-limiting heater prevents
temperature overload
• Easy to install and mount in compact
enclosures
The self-limiting block heater is powered utilising a direct power
reduction
or
low
stage
as
a
operating/ambient
result
of
Joule-Thomson
temperature
conditions
Two Stage Heating Technology
The GHR provides two stages of heating (pre & post pressure
reduction) to ensure sufficient heat transfer throughout the
pressure reduction process.
Reduce Downtime
Preventing condensation of the sample gas has many benefits such
as: reducing regulator freeze-ups, preserving sample integrity, and
minimising maintenance costs
“
The GHR is the most effective
regulator on the market for
preventing condensation
“
• Prevents condensation of the sample
2. TECHNICALSPECIFICATION
POWER REQUIREMENTS
• 6,000 psig (414 Bar)
• 110 to 265 VAC, 80W
• 12VDC, 15W
• 24VDC, 30W
TEMPERATURE RANGES
WETTED MATERIALS
MAXIMUM PRESSURE RATING
• -15 ºF (-26 ºC ) to 300 ºF (149 ºC)
OUTLET PRESSURE RANGE
• 0-10 psig (0-0.7 bar), 0-25 psig (0-1.7 bar), 0-50 psig (0-3.4
• Machined parts: 316 stainless steel / NACE compliant
• All other metal parts: stainless steel / NACE compliant
• Regulator seat material: PFA
• Seals: PTFE / Fluoroelastomer
bar),0-100 psig (0-6.9 bar), 0-250 psig (0-17.2 bar), 0-500
HEATER BLOCK ELECTRICAL APPROVALS
psig (34.5 bar)
ATEX/ IECEx Standard
• EC Examination Certificate - PTB 02 ATEX 1116 X
• IEC Scheme Certificate - IECEx PTB 07.0055X
• Protection Type: II 2 G Ex d IIC T4 BZW. T3
DIMENSIONS
• Port sizes: 1/4” female NPT
• Conduit connection: 1/2” NPT
PARTBUILDER
MODEL NUMBERING & ADDITIONAL PART NUMBERS
•
•
•
•
Sealing material
0 = Fluoroelastomer JW = James Walker® Elast-O-Lion® 101 (other materials available upon request)
Outlet pressure range (psig)
0 = 0-25
1 = 0-50
2 = 0-100
3 = 0-250
4 = 0-500
9 = 1-10
Supply voltage 1 = 110 To 265 VAC, 80W 2 = 24VDC, 30W 3 = 12 VDC, 15W (other supply voltages available upon request)
Electrical approval
C = CSA/NRTL (CI. 1, Div. 1, Grp ABCD) A = ATEX/IECEx (II 2 G Ex d IIC T4 bzw. T3)
(other electrical approvals available upon request)
How to build the model number:
How to build the heater block replacement model:
11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT
T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com
W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com
Cert No. 996
ISO 9001