Coterd Laboratory details and testing of ac

  1. 1. Psychrometric Lab Performance Testing of AC
  2. 2. Product Testing – As per IS1391 Part 1 and IS1391 Part 2 standards  ON/OFF or Fixed Speed (SAC/WAC/CAC/Packaged AC)  DC Inverter AC (SAC/WAC)  Refrigerant (R410A, R32, R290, R22)  Testing SCOPE – As per IS Standard (Psychometric lab/Enthalpy Lab)  Cooling Capacity/ Performance Testing  Power Consumption, EER and ISEER as per BEE 2018 Standards.  Power Factor, Frequency  Max. Operating Condition Test (Low and High Voltage as per IS Conditions)  Freeze up Test  Sweat & Closure Test  Air Flow Measurement  Noise Testing can be done as per IS1391 Part 2 (2018 Amendment 1) in Psychrometric lab  Heating Capacity  Heating Overload condition testing 2 www.coterd.com
  3. 3. Psychrometric Laboratory Details:  Lab Type: Psychrometric/ Enthalpy Lab  Rated cooling capacity (T1, T2, T3)  Capacity of Lab: 5 HP  Cooling capacity 9000Btu/hr to 60000 Btu/hr  Heating capacity 9000Btu/hr to 60000 Btu/hr  Air flower rate(Indoor): 250~5000m3/h  Power:  1ф 100~300V/50/60Hz 60A continuous rating (Rating 230V).  3ф 200~500V50/60Hz 30A continuous rating (Rating 415V).  Other test conditions  Indoor ﹢10~50℃ 20~90%RH (dew point ≥8℃)  Outdoor -5~55℃ 20~90%RH (dew point ≥8℃)Size:  Window type: W-under 1000mm; D-under 900mm; H-under 800mm  Split type: W-under 1800mm; D-under 1000mm; H-under 2000mm  Working Capability (24*7) as per customer requirement 3 www.coterd.com
  4. 4. NABL Accredited:  All IS and ISO standard covered as per NABL ISO 17025; 2005 & 2017. 4 SCOPE OF NABL (ISO/IEC 17025:2005) ELECTRICAL TESTING DOMESTIC ELECTRICAL APPLIANCES Room Air Condition (Window, Split and Inverter Type) Cooling Capacity IS 1391 (Part 1) CI. 10. 10 2500 W to 12000 WIS 1391 (Part 2) CI. 9. 9 Power Consumption for cooling IS 1391 (Part 1) CI. 10. 8 100 W to 5000 W IS 1391 (Part 2) CI. 9.7 Maximum operating Conditions IS 1391 (Part 1) CI. 10. 4 Qualititative (2500 W to 12000 W)IS 1391 (Part 2) CI. 9.4 Enclosure Sweat IS 1391 (Part 1) CI. 10. 6 Qualitative (2500 W to 12000 W)IS 1391 (Part 2) CI. 9.6 Condensate Disposal IS 1391 (Part 1) CI. 10. 7 Qualitative (2500 W to 12000 W) Freeze UP IS 1391 (Part 1) CI. 10. 5 Qualitative (2500 W to 12000 W)IS 1391 (Part 2) CI. 9.5 www.coterd.com
  5. 5. Our Project Execution Process: 5 AC Manufacturer COTERD Lab Availability All AC Testing Report Generation Send to Customer www.coterd.com
  6. 6. Thank You ! 6 www.coterd.com

×