Mitsubishi low voltage ws-v series comparison of previous and new models
1. 1. Product Lineup …………………………………………… 2
2. Comparison of Previous and New Models……………… 3
3. Replacement of Previous Models with New Models …… 6
4. Compatibility of Optional Accessories…………………… 9
5. Outline Dimensions of Previous and New Models……… 12
( 3 0 t o 2 5 0 A F r a m e )
Comparison of Previous and New Models
MOLDED-CASE CIRCUIT BREAKERS & EARTH-LEAKAGE CIRCUIT BREAKERS
MOLDED-CASE CIRCUIT BREAKERS &
EARTH-LEAKAGE CIRCUIT BREAKERS
3. 2. Comparison of Previous and New Models
Series Previous W & WS Series New WS-V Series Differences in dimensions and performance between previous and new models
NF-C
NF63-CW NF63-CV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Change to running on both AC/DC
Increase in breaking capacity
NF125-CW NF125-CV No changes in dimensions and performance
NF250-CW NF250-CV
Same dimension
Change in instantaneous value of 250 A rated model (from 10 times to 12 times ± 20%)
Increase in breaking capacity
NF-S
NF32-SW NF32-SV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Change to running on both AC/DC
Increase in breaking capacity
NF63-SW NF63-SV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Change to running on both AC/DC
Increase in breaking capacity
NF125-SW NF125-SV
Same dimension
Increase in breaking capacity
Capable of breaking 690 V AC
NF125-SGW RT NF125-SGV
Change in depth (from 86 mm to 68 mm)
Change in rated current adjustable range
Adjustable instantaneous value ➞ Unadjustable
NF125-SGW RE NF125-SEV Change in depth (from 86 mm to 68 mm)
NF160-SW NF250-SV 125 150 160A Addition of 160 A model
NF160-SGW RT NF160-SGV
Change in depth (from 86 mm to 68 mm)
Adjustable instantaneous value ➞ Unadjustable
NF160-SGW RE NF250-SEV 80-160A
Change in depth (from 86 mm to 68 mm)
Addition of 80-160 A model
NF250-SW NF250-SV
Same dimension
Change in instantaneous value of 250 A rated model (from 10 times to 12 times ± 20%)
Increase in breaking capacity
Capable of breaking 690 V AC
NF250-SGW RT NF250-SGV
Change in depth (from 86 mm to 68 mm)
Adjustable instantaneous value ➞ Unadjustable
NF250-SGW RE NF250-SEV Change in depth (from 86 mm to 68 mm)
− 2 −
4. Series Previous W & WS Series New WS-V Series Differences in dimensions and performance between previous and new models
NF-H
NF63-HW NF63-HV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Change to running on both AC/DC
Increase in breaking capacity
NF125-HW NF125-HV
Same dimension
Applicable to rated current of 125 A
Increase in breaking capacity
NF125-HGW RT NF125-HGV
Change in depth (from 86 mm to 68 mm)
Change in rated current adjustable range
Adjustable instantaneous value ➞ Unadjustable
Decrease in breaking capacity at 690 V AC
NF125-HGW RE NF125-HEV
Change in depth (from 86 mm to 68 mm)
Decrease in breaking capacity at 690 V AC
NF160-HW NF250-HV 125 150 160A Addition of 160 A model
NF160-HGW RT NF160-HGV
Change in depth (from 86 mm to 68 mm)
Adjustable instantaneous value ➞ Unadjustable
Decrease in breaking capacity at 690 V AC
NF160-HGW RE NF250-HEV 80-160A
Addition of 80-160 A model
Change in depth (from 86 mm to 68 mm)
Decrease in breaking capacity at 690 V AC
NF250-HW NF250-HV
Same dimension
Applicable to rated current of 250 A (instantaneous value = 12 times ± 20%)
Increase in breaking capacity
NF250-HGW RT NF250-HGV
Change in depth (from 86 mm to 68 mm)
Adjustable instantaneous value ➞ Unadjustable
Decrease in breaking capacity at 690 V AC
NF250-HGW RE NF250-HEV
Change in depth (from 86 mm to 68 mm)
Decrease in breaking capacity at 690 V AC
NF-U
NF125-RGW RT NF125-RGV
Changes in dimensions (height: from 240 mm to 165 mm, depth: from 86 mm to 68 mm)
Change in rated current adjustable range
Applicable to rated current of 125 A
Increase in breaking capacity at 415 V AC or less
Rated working voltage of below 500 V AC
NF125-UGW RT NF125-UGV
Change in depth (from 86 mm to 68 mm)
Change in rated current adjustable range
Applicable to rated current of 125 A
Decrease in breaking capacity at 690 V AC
NF250-RGW RT NF250-RGV
Changes in dimensions (height: from 240 mm to 165 mm, depth: from 86 mm to 68 mm)
Applicable to rated current of 250 A
Increase in breaking capacity at 415 V AC or less
Rated working voltage of below 500 V AC
NF250-UGW RT NF250-UGV
Change in depth (from 86 mm to 68 mm)
Applicable to rated current of 250 A
Decrease in breaking capacity at 690 V AC
NV-C
NV63-CW NV63-CV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
NV125-CW NV125-CV No changes in dimensions and performance
NV250-CW NV250-CV
Same dimension
Increase in breaking capacity
− 3 −
5. Series Previous W & WS Series New WS-V Series Differences in dimensions and performance between previous and new models
NV-S
NV32-SW NV32-SV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
NV63-SW NV63-SV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
NV125-SW NV125-SV
Same dimension
Increase in breaking capacity
NV250-SW NV250-SV
Same dimension
Increase in breaking capacity
NV250-SEW NV250-SEV
Same dimension
Applicable to rated current of 250 A
Increase in breaking capacity
NV-H
NV63-HW NV63-HV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
NV125-HW NV125-HV
Same dimension
Applicable to rated current of 125 A
Increase in breaking capacity
NV250-HW NV250-HV
Same dimension
Applicable to rated current of 250 A
Increase in breaking capacity
NV250-HEW NV250-HEV
Same dimension
Applicable to rated current of 250 A
Increase in breaking capacity
MB
MB50-CW NF63-CV (Note)
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
MB30-SW NF32-SV (Note)
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
MB50-SW NF63-SV (Note)
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
MB100-SW NF125-SV (Note)
Same dimension
Increase in breaking capacity
MB225-SW NF250-SV (Note)
Same dimensions and characteristics
Increase in breaking capacity
Note: The circuit breakers for motor protection have the same basic model names as NF/NV.
● New models
Model name Remarks
NF125-LGV, NF160-LGV, NF250-LGV Thermally adjustable models having breaking capacity of 50 kA at 440 V AC are newly introduced.
NV125-SEV, NV125-HEV Electronic breakers
− 4 −
6. 3. Replacement of Previous Models with New Models
(1) Circuit breaker body (front connection, with 3 poles)
NF32-SW
NF63-CW/SW/HW
MB30-SW
MB50-CW/SW
Previous
W & WS
Series
New
WS-V
Series
Drilling
dimension
Front plate
cutout plan
NF32-SV
NF63-CV/SV/HV
NF125-CW/SW/HW
MB100-SW
NF125-CV/SV/HV
Previous
W & WS
Series
New
WS-V
Series
Drilling
dimension
NV32-SW
NV63-CW/SW/HW
NV32-SV
NV63-CV/SV/HV
NV125-CW/SW/HW
NV125-CV/SV/HV
NV250-CW/SW/HW
NV250-SEW/HEW
NV250-CV/SV/HV
NV250-SEV/HEV
Front plate
cutout plan
No change
No change
No change No change No change No change
No change No change
No change No change No change
No change No change No change
No change No change
M4×0.7 screw
or φ5 hole
Breaker
111
25
Breaker
70
52
R
1
M4×0.7 screw
or φ5 hole
Breaker
111
30
Breaker
52
86
R
1
111
30
Breaker
M4×0.7
screw or
φ5 hole
R1
86
52
Breaker
25
111
M4×0.7 screw
or φ5 hole Breaker
70
52
R1
Breaker
NF160-SW/HW
NF250-CW/SW/HW
MB225-SW
NF250-CV/SV/HV
52
100
Breaker
R
1
35
126
Breaker
M4×0.7 screw
or φ5 hole
NF125-SGW/HGW
NF160-SGW/HGW
NF250-SGW/HGW
NF125-SGV/LGV/HGV
NF125-SEV/HEV
NF160-SGV/LGV/HGV
NF250-SGV/LGV/HGV
NF250-SEV/HEV
52
100
Breaker
R
1
35
126
Breaker
M4×0.7 screw
or φ5 hole
NF125-RGW/UGW
NF250-RGW/UGW
NF125-RGV
NF250-RGV
NF125-UGV
NF250-UGV
52
100
Breaker
R
1
35
126
Breaker
M4×0.7 screw
or φ5 hole
52
100
11.5
Breaker
R1
201
35
Breaker
M4×0.7
screw or
φ5 hole
35
126
Breaker
M4×0.7 screw
or φ5 hole
52
100
Breaker
R
1
change
change
− 5 −
7. (2) Circuit breaker and operating handle (front connection, 3P)
NF32-SW
NF63-CW/SW/HW
MB30-SW
MB50-CW/SW
Previous
W & WS
Series
New
WS-V
Series
Previousmodels
New models
Previousmodels
New models
Previousmodels
New models
Drillingdimensionsformountingofcircuitbreaker
Frontplatecutoutdimensions
NF32-SV
NF63-CV/SV/HV
NV32-SW
NV63-CW/SW/HW
NV125-CW/SW/HW
NV32-SV
NV63-CV/SV/HV
NF125-CW/SW/HW
MB100-SW
NF125-CV/SV/HV NV125-CV/SV/HV
105 mm
102 mm
CircuitbreakerbodyFtype
FtypeStypeVtype
StypeVtype
FtypeStypeVtype
Distancebetween
circuitbreaker
bottomandfront
plate
F-05S2, F-05S, F-05SE
F-05SV2, F-05SV, F-05SVE
S-05SW
S-05SV
V-05S, V-05SE
V-05SV, V-05SVE
S-1SW
S-05SV
V-1S, V-1SE
V-1SV, V-1SVE
F-05S, F-05SE
F-05SV, F-05SVE
F-1S2, F-1S, F-1SE
F-1SV2, F-1SV, F-1SVE
F-1S, F-1SE
F-1SV, F-1SVE
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
125 mm (stationary type)
No change
125 mm (stationary type)
− 6 −
8. Previous
W & WS
Series
New
WS-V
Series
Previousmodels
New models
Previousmodels
New models
Previousmodels
New models
Drillingdimensionsformountingofcircuitbreaker
Frontplatecutoutdimensions
CircuitbreakerbodyFtype
FtypeStypeVtype
StypeVtype
FtypeStypeVtype
Distancebetween
circuitbreaker
bottomandfront
plate
NF160-SW/HW
NF250-CW/SW/HW
NF250-SEW/HEW
MB225-SW
NF250-CV/SV/HV
NF250-SEV/HEV
NV250-CW/SW/HW
NV250-SEW/HEW
NV250-CV/SV/HV
NV250-SEV/HEV
NF125-SGW/HGW
NF160-SGW/HGW
NF250-SGW/HGW
NF125-SGV/LGV/HGV
NF125-SEV/HEV
NF160-SGV/LGV/HGV
NF250-SGV/LGV/HGV
NF250-SEV/HEV
NF125-RGW/UGW
NF250-RGW/UGW
NF125-RGV
NF250-RGV
NF125-UGV
NF250-UGV
No change
No change
No change
No change
No change
No change
No change
No change
No change
125 mm (stationary type)
F-2S, F-2SE
F-2SV, F-2SVE
S-2SW
S-2SV
V-2S, V-2SE
V-2SV, V-2SVE
F-2UG, F-2UGE
−
V-2UG, V-2UGE
F-2SG, F-2SGE
F-2SV, F-2SVE
S-2GSW
S-2SV
V-2SG, V-2SGE
V-2SV, V-2SVE
F-2SV, F-2SVE
S-2SV
V-2SV, V-2SVE
F-2UV, F-2UVE
−
V-2UV, V-2UVE
New models
110 mm
Previous models
128 mm
New models
107 mm
Previous models
125 mm
No change
No change
No change
No change No changeNo changeNo change
Previous models
143 mm
(stationary type)
New models
125 mm
(stationary type)
New models
110 mm
Previous models
128 mm
New models
107 mm
Previous models
125 mm
Previous models
143 mm
(stationary type)
New models
125 mm
(stationary type)
New models
110 mm
Previous models
128 mm
New models
107 mm
Previous models
125 mm
Previous models
143 mm
(stationary type)
New models
125 mm
(stationary type)
Center of circuit
breaker handle Center of circuit
breaker handle
Center of
circuit
breaker
Center of
operating
handle M4×0.7 screw
or φ5 hole
M4×0.7 screw
or φ5 hole
Previous model New model
Center of
circuit
breaker
and
operating
handle
Differing in hole position
Center of
operating
handle
Center of
operating
handle
M4×0.7 screw
or φ5 hole
M4×0.7 screw
or φ5 hole
M4×0.7 screw
or φ5 hole
M4×0.7 screw
or φ5 hole
Previous model New model
Previous model New model
Center of
circuit
breaker
and
operating
handle
Center of
circuit
breaker
and
operating
handle
Breaker
Breaker
Differing in hole position
Differing in hole position
Center of circuit
breaker handle
Center of circuit
breaker handle
Center of circuit
breaker and circuit
breaker handle
Center of circuit
breaker and circuit
breaker handle
Center of
circuit
breaker
Center of
circuit
breaker
− 7 −
9. Products
Models Compatibility
Accessories
Applicable models (New models)
New breakers
with previous
accessories
Previous
breakers with
new accessoriesPrevious models New models
Cassette-
type
accessories
(Note)
AL-05SW* AX-05SW*
ALAX-05SW*
AL-05SV* AX-05SV*
ALAX-05SV*
NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
AL-1SW AX-1SW ALAX-1SW NF/NV125-CV/SV/HV ✕ ✕
AL-2SW* AX-2SW*
ALAX-2SW*
NF/NV250-CV/SV/HV ✕ ✕
AL-2GSW* AX-2GSW*
ALAX-2GSW*
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
SHTMMMM-05SWR
SHTMMMM-05SVR
NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
SHTMMMM-1SWR NF/NV125-CV/SV/HV ✕ ✕
SHTMMMM-2SWR NF/NV250-CV/SV/HV ✕ ✕
SHTMMMM-2GSWR
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
UVTNMMMM-05SW*
UVTNMMMM-05SV*
UVTSMMMM-05SV*
NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
UVTNMMMM-1SW* NF/NV125-CV/SV/HV ✕ ✕
UVTNMMMM-2SW* NF/NV250-CV/SV/HV ✕ ✕
UVTSMMMM-2GSW*
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
Rear stud
(B-ST)
ST-05SW2, 3, 4 ST-05SV2, 3, 4 NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
ST-1SW2, 3, 4 ST-1SV2, 3, 4 NF/NV125-CV/SV/HV(3, 4P) ✕ ✕
ST-1HW2 ST-1HV2 NF125-HV(2P) ✕ ✕
ST-2SW2, 3, 4
ST-2SV2, 3, 4
NF/NV250-CV/SV/HV ✕ ✕
ST-2GSW2, 3, 4
NF125-SGV/LGV/HGV/SEV/HEV,
NF250-SGV/LGV/HGV/SEV/HEV, etc.
✕ ✕
Plug-in
terminal
(PM)
PM-05SW2, 3, 4 PMDN-05SV2, 3, 4 NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
PM-NV05SW2 PMDN-NV05SV2 NV63-CV/SV(2P) ✕ ✕
PM-1SW2, 3, 4 PMDN-1SV2, 3, 4 NF/NV125-CV/SV/HV ✕ ✕
PM-1HW2 PMDN-1HV2 NF125-HV(2P) ✕ ✕
PM-2SW2, 3, 4
PMDN-2SV2, 3, 4
NF/NV250-CV/SV/HV ✕ ✕
PM-2GSWIP2, 3, 4
NF125-SGV/LGV/HGV/SEV/HEV,
NF250-SGV/LGV/HGV/SEV/HEV, etc.
✕ ✕
PM-2GUW2, 3
PMDN-2SV2, 3 NF125-RGV, NF250-RGV ✕ ✕
PMDN-2UV2, 3 NF125-UGV, NF250-UGV ✕ ✕
Conductor
(FB)
FB-05SW FB-05SV
NF/NV32-SV,
NF/NV63-CV/SV/HV (50A or less)
K K
FB-1SW FB-1SV NF/NV125-CV/SV/HV K K
FB-2SW FB-2SV NF/NV250-CV/SV/HV K K
Barrier
BAF-05SW BAF-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV,
NF/NV125-CV/SV/HV, etc.
K K
BAF-2SW BAF-2SV NF/NV250-CV/SV/HV, etc. K ✕
BAG-05SW3 BAG-05SV3 NF/NV32-SV, NF/NV63-CV/SV/HV K K
BAG-1SW3 BAG-1SV3 NF/NV125-CV/SV/HV K K
BAG-2SW3
BAG-2SV3
NF/NV250-CV/SV/HV, etc. K K
BAG-2GSW3
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
✕ ✕
4. Compatibility of Optional Accessories
Note: In *, a symbol indicating the mounting pole is shown. In M, the voltage is shown.
− 8 −
10. Products
Models Compatibility
Accessories
Applicable models (New models)
New breakers
with previous
accessories
Previous
breakers with
new accessoriesPrevious models New models
Operating
handle
F-05S2 F-05SV2 NF32-SV(2P), NF63-CV/SV/HV(2P) ✕ ✕
F-05S F-05SV NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
F-1S2 F-1SV2 NF125-CV/SV(2P) ✕ ✕
F-1S F-1SV NF/NV125-CV/SV/HV ✕ ✕
F-2S
F-2SV
NF/NV250-CV/SV/HV ✕ ✕
F-2SG
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
✕ ✕
F-2UG F-2UV NF125-UGV, NF250-UGV ✕ ✕
F-RCS (release protection) F-RCS (release protection)
F type operating handle is applicable to all
models.
K K
S-05SW S-05SV NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
S-1SW S-1SV NF/NV125-CV/SV/HV ✕ ✕
S-2SW
S-2SV
NF/NV250-CV/SV/HV ✕ ✕
S-2GSW
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
✕ ✕
V-05S2 V-05SV2 NF32-SV(2P), NF63-CV/SV/HV(2P) ✕ ✕
V-05S V-05SV NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
V-1S2 V-1SV2 NF125-CV/SV(2P) ✕ ✕
V-1S V-1SV NF/NV125-CV/SV/HV ✕ ✕
V-2S
V-2SV
NF/NV250-CV/SV/HV ✕ ✕
V-2SG
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
✕ ✕
V-2UG V-2UV NF125-UGV, NF250-UGV ✕ ✕
V-AD3S (adjusting unit) V-AD3S (adjusting unit)
V type operating handle is applicable to all
models.
K K
Clamp
TG-S05SW TG-S05SV NF/NV32-SV, NF/NV63-CV/SV/HV, etc. K K
TG-S2SW TG-S2SV NF/NV250-CV/SV/HV, etc. K K
TC-S
TCS-05SW2W, 3W, 4W TCS-05SV2, 3, 4 NF/NV32-SV, NF/NV63-CV/SV/HV K K
TCS-1SW2W, 3W, 4W TCS-1SV2, 3, 4 NF/NV125-CV/SV/HV K K
TCS-2SW3W, 4W
TCS-2SV3, 4
NF/NV250-CV/SV/HV K K
TCS-2GSW3W, 4W
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
TC-L
TCL-05SW2W, 3W, 4W TCL-05SV2, 3, 4 NF/NV32-SV, NF/NV63-CV/SV/HV K K
TCL-1SW2W, 3W, 4W TCL-1SV2, 3, 4 NF/NV125-CV/SV/HV K K
TCL-2SW3W, 4W TCL-2SV3, 4
TCL-2SV3L
NF/NV250-CV/SV/HV K K
TCL-2GSW3W, 4W
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
TTC
TTC-05SW2, 3 TTC-05SV2, 3 NF/NV32-SV, NF/NV63-CV/SV/HV K K
TTC-1SW2, 3 TTC-1SV2, 3 NF/NV125-CV/SV/HV K K
TTC-2SW3
TTC-2SV3
NF/NV250-CV/SV/HV K K
TTC-2GSW3
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
BTC
BTC-05SW2W, 3W BTC-05SV2, 3 NF/NV32-SV, NF/NV63-CV/SV/HV K K
BTC-1SW2W, 3W BTC-1SV2, 3 NF/NV125-CV/SV/HV K K
BTC-2SW3W
BTC-2SV3
NF/NV250-CV/SV/HV K K
BTC-2GSW3W
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
PTC
PTC-05SW2W, 3W PTC-05SV2, 3 NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
PTC-1SW2W, 3W PTC-1SV2, 3 NF/NV125-CV/SV/HV ✕ ✕
PTC-2SW3W
PTC-2SV3
NF/NV250-CV/SV/HV ✕ ✕
PTC-2GSW3W
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
− 9 −
11. Note: In *, a symbol indicating the mounting pole is shown. In M, the voltage is shown.
Products
Models Compatibility
Accessories
Applicable models (New models)
New breakers
with previous
accessories
Previous
breakers with
new accessoriesPrevious models New models
Lock cover
LC-05SW LC-05SV NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
LC-1SW LC-1SV NF/NV125-CV/SV/HV ✕ ✕
LC-2SW
LC-2SV
NF/NV250-CV/SV/HV ✕ ✕
LC-2GSW
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
Handle lock
HLF-05SW, HLN-05SW HLF-05SV, HLN-05SV NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
HLF-1SW, HLN-1SW HLF-1SV, HLN-1SV NF/NV125-CV/SV/HV ✕ ✕
HLF-2SW, HLN-2SW
HLF-2SV, HLN-2SV
NF/NV250-CV/SV/HV ✕ ✕
HLF-2GSW, HLN-2GSW
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
HLS-05SW, HLS-05SW2P HLS-05SV, HLS-05SV2P NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
HLS-1SW, HLS-1SW2P HLS-1SV, HLS-1SV2P NF/NV125-CV/SV/HV ✕ ✕
HLS-2SW
HLS-2SV
NF/NV250-CV/SV/HV ✕ ✕
HLS-2GSW
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
✕ ✕
SBOX
NFS-05SW2P NFS-05SV2P NF32-SV(2P), NF63-CV/SV/HV(2P), etc. K K
NFS-05SW NFS-05SV NF/NV32-SV, NF/NV63-CV/SV/HV K K
NFS-1SW2P NFS-1SV2P NF125-CV/SV K K
NFS-1SW NFS-1SV NF/NV125-CV/SV/HV K K
NFS-2SW NFS-2SV NF/NV250-CV/SV, etc. K K
IBOX
NFI-05SW NFI-05SV NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
NFI-1SW NFI-1SV NF/NV125-CV/SV/HV ✕ ✕
NFI-2SW NFI-2SV NF/NV250-CV/SV/HV, etc. ✕ ✕
WBOX
NFW-05SW NFW-05SV NF/NV32-SV, NF/NV63-CV/SV/HV ✕ ✕
NFW-1SW NFW-1SV NF/NV125-CV/SV ✕ ✕
NFW-1HW NFW-1HV NF/NV125-HV ✕ ✕
NFW-2SW NFW-2SV NF/NV250-CV/SV/HV, etc. ✕ ✕
Electric
operation
unit
(Note)
MDSMMMM-NF1SWE MDSMMMM-NF1SVE NF125-CV/SV/HV ✕ ✕
MDSMMMM-NV1SWE MDSMMMM-NV1SVE NV125-CV/SV/HV ✕ ✕
MDSMMMM-NF2SWE MDSMMMM-NF2SVE NF250-CV/SV/HV ✕ ✕
MDSMMMM-NF2GSWE MDSMMMM-NF2SVE
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
✕ ✕
MDSMMMM-NV2SWE MDSMMMM-NV2SVE NV250-CV/SV/HV ✕ ✕
Mechanical
interlock
MI-05SW3 MI-05SV3
NF/NV32-SV, NF/NV63-CV/SV/HV,
NF/NV125-CV/SV/HV, NF/NV250-CV/SV/HV,
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
K K
IEC 35 mm
rail mounting
adapter
DIN-05SW DIN-05SV NF/NV32-SV, NF/NV63-CV/SV/HV, etc. ✕ ✕
DIN-1SW2 – No new models ✕ –
DIN-1SW3 – No new models ✕ –
Card holder CH-P NO.5 CH-P NO.5 NF/NV250-SV or lower K K
− 10 −
12. Previous W & WS Series New WS-V Series
Models Reference page Models Reference page
NF32-SW, NF63-CW, NF63-SW, NF63-HW 13 NF32-SV, NF63-CV, NF63-SV, NF63-HV 14
NV32-SW, NV63-CW, NV63-SW, NV63-HW 15 NV32-SV, NV63-CV, NV63-SV, NV63-HV 16
NF125-CW, NF125-SW, NF125-HW 17 NF125-CV, NF125-SV, NF125-HV 18
NV125-CW, NV125-SW, NV125-HW 19 NV125-CV, NV125-SV, NV125-HV 20
NF250-CW, NF250-SW, NF250-HW,
MB225-SW
21 NF250-CV, NF250-SV, NF250-HV 22
NV250-CW, NV250-SW, NV250-HW 23 NV250-CV, NV250-SV, NV250-HV 24
NV250-SEW, NV250-HEW 25 NV250-SEV, NV250-HEV 26
NF125-SGW, NF125-HGW,
NF160-SGW, NF160-HGW,
NF250-SGW, NF250-HGW
27
NF125-SGV, NF125-LGV, NF125-HGV,
NF125-SEV, NF125-HEV,
NF160-SGV, NF160-LGV, NF160-HGV,
NF250-SGV, NF250-LGV, NF250-HGV,
NF250-SEV, NF250-HEV
28
NF125-RGW, NF250-RGW 29 NF125-RGV, NF250-RGV 30
NF125-UGW, NF250-UGW 31 NF125-UGV, NF250-UGV 32
MB30-SW, MB50-CW, MB50-SW 13 NF32-SV, NF63-CV, NF63-SV (Note) 14
MB100-SW 17 NF125-SV (Note) 18
5. Outline Dimensions of Previous and New Models
Note: The circuit breakers for motor protection have the same basic model names as NF.
− 11 −
13. Wire size applicable to
direct connection of wire
φ1.6 22 mm2
CL
CL
LC
LC
22
Neutral pole
Insulating barrier
(removable)
Mounting hole
Trip
button
25
50 50
75
25
75
100
50130
111
12.5 max.
6
φ5.5
(φ6.5 for 60 A and 63 A)
LC
CL
CLCL
Breaker
Drilling plan
M4 × 0.7 screw
or φ5 hole
2525
111
50
84
24
45
φ8.5
61
68
724
90
M5 × 0.8 screw
(M6 screw for 60 A and 63 A)
φ4.5
Conductor drilling
for direct connection
(Conductor thickness t = 5 max.)
LC
CL LC LC
φ14
Breaker
M4 × 0.7 screw
or φ5 hole
Drilling plan
111
25
25
75
25
5025
27 min.
8
72
68
42
111
8
50
Mounting plate t = 3.2 max.
Insulating tube
M6 screw
M4 × 0.7 screw
for breaker mounting
LC
LC
Front-panel cutout
1.0 mm clearance on each side
of the handle frame
CL
CL
50
2-pole
3-pole
CL
LC
22.5
70
52
4-pole
Breaker
CL LC LC
Center of
circuit breaker
body
Drilling plan
Breaker (plug-in terminal block)
M5 × 0.8 screw
or φ6 hole
54
545480
57 82
25
107
50
Conductor drilling drawing
4-pole3-pole
50
80
75
25
105
111
55
25
16.5 max.
7
φ6.5
LC
11
Plug-in terminal block
Mounting plate
Details of terminal
M6 screw
M5 × 0.8 screw
Mounting with terminal block
mounting nut or mounting
directly with screw
3
180
83.5
85
30
21
89
5.5 15.5
10
R1
2-pole 3-pole 4-pole
2-pole 3-pole 4-pole
2-pole 3-pole 4-pole
2-pole 3-pole 4-pole2-pole
Molded-case circuit breakers
Previous W & WS Series
NF32-SW, NF63-CW, NF63-SW, NF63-HW,
MB30-SW, MB50-CW, MB50-SW
Front connection
Rear connection
Plug-in
− 12 −
14. 42 (44 for 60 A and 63 A)
21
3089
11
7
16.5 max.
57 82
25 50
107
548054
54
83.5
85
170
116
80
50
25
55
105
75
25
5.5
φ6.5
8
Mounting plate
t = 3.2 max.
Insulating tube
50
22.5
φ14
70
52
R1
111
25
25
75
25
5025
50
4268
72
8
27 min.
27 min.
112
112
Mounting hole
22
25
50
50
75
25
75
100
50130
Insulating barrier
(removable)
Neutral pole
Trip
button
8
φ8.5
45
50
84
24
61
68
724
90
12.5 max.
φ4.5
φ5.5
(φ8.5 for 60 A and 63 A)
(16 max. for
60 A and 63 A)
(31 min. for 60 A and 63 A)
(29 min. for 60 A and 63 A)
(46 for 60 A and 63 A)
M5 × 0.8 screw
(M8 screw for 60 A and 63 A)
(Conductor thickness t = 5 max.)
Conductor drilling
for direct connection
2525
111
Breaker
M4 × 0.7 screw or φ5 hole
Breaker
M4 × 0.7 screw or φ5 hole
M6 screw
M4 × 0.7 screw
for breaker
mounting
Drilling plan Front-panel cutout
1.0 mm clearance on each side of the
handle frame
2-pole
3-pole
4-pole
Breaker
Breaker (plug-in terminal block)
M5 × 0.8 screw
or φ6 hole
4-pole3-pole
Plug-in terminal block
Mounting plate
M6 screw
M5 × 0.8 screw for
mounting terminal block
Wire size applicable to
direct connection of wire
φ1.6 22mm2
(For M5 × 0.8 screw)
Drilling plan
Drilling plan
Details of terminal Conductor drilling drawing
Molded-case circuit breakers
New WS-V Series
NF32-SV, NF63-CV, NF63-SV, NF63-HV
Front connection
Rear connection
Plug-in
2-pole 3-pole 4-pole
2-pole 3-pole 4-pole
2-pole
2-pole
3-pole 4-pole
2-pole 3-pole 4-pole
112
− 13 −
15. 25
6
12.5 max.
90
4 72
68
61
φ8.5
φ4.5
45
24
84
75
50
22
111
130
111
50
Mounting hole
Insulating barrier
(removable)
Sensitivity current
switching unit
Earth-leakage
indicating button
Test button
Trip button
M5 × 0.8 screw
(M6 screw for 60 A and 63 A)
φ5.5
(φ6.5 for 60 A and 63 A)
Wire size applicable to
direct connection of wire
φ1.6 22 mm2
Breaker
M4 × 0.7 screw
or φ5 hole
Drilling plan
LC
LC
LC
LC
27 min.
8
72
68
42
111
8
50
50
25
111
Mounting plate t = 3.2 max.
Insulating tube
M6 screw
M4 × 0.7 screw
for breaker mounting
φ14
M4 × 0.7 screw
or φ5 hole
Breaker
Drilling plan
LC
LC
LC
LC
52
70
Breaker
Front-panel cutout
1.0 mm clearance on each side of the
handle frame
R
1
LC
LC
10
15.5
5.5
89
21
30
85
83.5
180
3
7
16.5 max.
111
80
50
25
82
805454
54
11
Plug-in terminal block
Mounting plate
M5 × 0.8 screw
Mounting with terminal block
mounting nut or mounting
directly with screw
M6 screw
φ6.5
Conductor drilling drawing
M5 × 0.8 screw or φ6 hole
Breaker (plug-in terminal block)
Center of
circuit breaker
body
Drilling plan
LC
LC
50
Conductor drilling
for direct connection
(Conductor thickness t = 5 max.)
Details of terminal
Earth-leakage circuit breakers
Previous W & WS Series
NV32-SW, NV63-CW, NV63-SW, NV63-HW
Front connection
Rear connection
Plug-in
− 14 −
16. 112
8
72
68 42
50
50
25
R1
52
70
φ14
φ4.5
25
90
4 72
68
61
24
84
75
50
22
50
φ6.5
111
130
112
50
8
5.5
50
80
116
170
85
54
548054
25
82
7
11
89 30
21
8
45
φ8.5
12.5 max.
(16 max. for
60 A and 63 A)
Mounting hole
Insulating barrier
(removable)
Sensitivity current
switching unit
Earth-leakage
indicating button
Test button
Trip
button
M5 × 0.8 screw
(M8 screw for 60 A and 63 A)
φ5.5
(φ8.5 for 60 A and 63 A)
Breaker
M4 × 0.7 screw
or φ5 hole
Conductor drilling
for direct connection
(Conductor thickness t = 5 max.)
27 min.
Mounting plate
t = 3.2 max. Insulating tube
M6 screw
M4 × 0.7 screw
for breaker mounting
M4 × 0.7 screw
or φ5 hole
Breaker
Drilling plan
Drilling plan
Breaker
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
16.5 max.
Plug-in terminal block
Mounting plate
M6 screw
Conductor drilling drawing
M5 × 0.8 screw
or φ6 hole
Breaker (plug-in terminal block)
Drilling plan
83.5
M5 × 0.8 screw
for mounting terminal block
Details of terminal
Earth-leakage circuit breakers
New WS-V Series
NV32-SV, NV63-CV, NV63-SV, NV63-HV
Front connection
Rear connection
Plug-in
Wire size applicable to direct
connection of wire
φ1.6 22 mm2
(For M5 × 0.8 screw)
111
112
− 15 −
17. CL
LC
LC
CL
50Neutral pole
30
90
120
112
130
60
30
90
60
22
Trip
button
Insulating barrier
(removable)
Mounting hole
CLLCLC
LC
30
110-111
(Note1)
30
Breaker
Drilling plan
M4 × 0.7 screw
or φ5 hole
24
84
50
68
61
45
724
90
φ8.5
8
M8 screw
19 max. (comb-like
conductor: 16.5 max.)
Conductor drilling
for direct connection
(Conductor thickness t = 5 max.)
φ8.5
φ4.5
CL
102
15
72
68
8.5
2.5
15
54.5
104.5
15
2.5
16
112
Mounting plate
t = 3.2 max.
Stud rotatable by 90°
Insulating tube
Connecting
allowance
M8 bolt
90
8
60
5
Insulating tube
M4 × 0.7 screw
for breaker mounting
LCCL
CL
LC
30 110-111(Note1)
90
30
112
30
60
30
M4 × 0.7 screw or φ5 hole
Breaker
Drilling plan
φ18
LC
LCLC
LC
28
57 86
52
Breaker
R1
R1
CL
89
12.5
Plug-in terminal block
Mounting plate
98
190
11
21
30
5.5 20
Details of terminal
M8 screw
M5 × 0.8 screw
Mounting with terminal block
mounting nut or mounting
directly with screw
Drilling plan
CL
LC CL CL
Breaker (plug-in terminal block)
54
945656
127
6030
9767
M5 × 0.8
screw or φ6
hole
30
95
60
125
90
30
65
16.5 max.
12
φ8.5
Conductor drilling drawing
134
2-pole
3-pole 4-pole
Front-panel cutout
1.0 mm clearance on each side of the
handle frame
Molded-case circuit breakers
Previous W & WS Series
NF125-CW, NF125-SW, NF125-HW,
MB100-SW
Front connection
Rear connection
Plug-in
Note (1) Applicable to both mounting sizes 110 and 111
Remarks: 1. 2-pole model of NF125-HW are 3-pole model with the central pole removed.
2. Only 2- and 3-pole models are available for the model of NF125- CW and only 3-pole models are available for the model of MB100-SW.
2-pole 3-pole 4-pole
2-pole
3-pole 4-pole
2-pole
2-pole
3-pole 4-pole
3-pole 4-pole
2-pole
3-pole
4-pole
2-pole 3-pole
4-pole
Solderless terminal
for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 16 −
18. Drilling plan
111
111
8
φ8.5
φ8.5
φ18
φ4.5
R1
R1
30
50
90
30
90
120
28
90
30
112
30
112
130
102
52
15
72
68
8.5
2.5
15
54.5
104.5
15
2.5
16
112
60
5
30 57 86
52
60
30
60
30
90
60
22
24
84
50
68
61
45
724
90
8
30
5.5
83.5
85
170
12
3089
21
11
54
805656
67 97 127
60
95
30
65
116
30
90
125
Mounting hole
Insulating barrier
(removable)
Trip
button
Neutral pole
M8 screw
Conductor drilling
for direct connection
(Conductor thickness t = 5 max.)
Drilling plan
M4 × 0.7 screw or φ5 hole
19 max.
(comb-like conductor: 16.5 max.)
Breaker
Breaker
Breaker
Front-panel cutout
M4 × 0.7 screw
or φ5 hole
Drilling plan
M4 × 0.7 screw
for breaker mounting
Insulating tube
Mounting plate
t = 3.2 max.
Insulating tube
Stud rotatable by 90°
Connecting
allowance
M8 bolt
Breaker (plug-in terminal block)
M5 × 0.8 screw
or φ6 hole
φ8.5
Conductor drilling
drawing
20 max.
Details of terminal
Plug-in terminal block
Mounting plate
M5 × 0.8 screw
Mounting with terminal
block mounting nut or
mounting directly with screw
M8 screw
1.0 mm clearance on each side of the
handle frame
2-pole
2-pole
3-pole
3-pole
4-pole
4-pole
2-pole
3-pole
4-pole
2-pole 3-pole
4-pole
Molded-case circuit breakers
New WS-V Series
NF125-CV, NF125-SV, NF125-HV
Front connection
Rear connection
Plug-in
2-pole 3-pole 4-pole
2-pole 3-pole 4-pole
2-pole 3-pole 4-pole
Remarks: 1. 2-pole model of NF125-SV are 3-pole models with the central pole removed.
2. Only 2- and 3-pole models are available for the model of NF125-CV.
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 17 −
19. CLLC
LC
3030
Breaker
Drilling plan
M4 × 0.7 screw
or φ5 hole
CL
LC
LC
Trip
button
Trip
button
Operating time
changing unit
(time delay type)
Sensitivity current
switching unit
Test button
Earth-leakage
indicating button
120
90
30 Neutral pole
Earth-leakage
indicating button
Test button
Sensitivity current
switching unit
Operating time
changing unit
130
112
50
90
60
22
Insulating barrier
(removable)
Mounting
hole
24
84
50
68
61
45
724
90
φ8.5
M8 screw
19 max. (comb-like
conductor: 16.5 max.)
Conductor drilling
for direct connection
(Conductor thickness t = 5 max.)
φ8.5
φ4.5
8
CL
102
52
Connecting
allowance 15
72
68
8.5
2.5
15
54.5
104.5
15
2.5
16
112
Mounting plate
t = 3.2 max.
Stud rotatable by 90°
Insulating tube
M8 bolt
90
60
5
8
Insulating tube
M4 × 0.7 screw
for breaker
mounting
LCCL
CL
110-111(Note1)
30
30
90
112
60
30
M4 × 0.7 screw or φ5 hole
Breaker
Drilling plan
φ18
LC
LC
LC
28
Breaker
52
86
R1
12.5
5.5 20
Details of terminal
16.5 max.
12
φ8.5
Conductor drilling
drawing
CL
89
Plug-in terminal block
Mounting plate
98
190
11
21
30
M8 screw
M5 × 0.8 screw
Mounting with terminal block
mounting nut or mounting
directly with screw
LC
Drilling plan
CL CL
Breaker (plug-in terminal block)
54
945656
127
6030
97
M5 × 0.8 screw
or φ6 hole
30
125
90
95
60
134
Note (1) Applicable to both mounting sizes 110 and 111
Remark: NV125-CW is available in 3-pole only.
110-111
(Note1)
Front-panel cutout
1.0 mm clearance on each side of the
handle frame
Earth-leakage circuit breakers
Previous W & WS Series
NV125-CW, NV125-SW, NV125-HW
Front connection
Rear connection
Plug-in
3-pole
4-pole
3-pole
4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
3-pole
3-pole
4-pole
4-pole
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 18 −
20. 111
111
8
19 max.
(comb-like conductor:
16.5 max.)
50
112
130
φ18
R1
30
50
90
30
90
120
28
90
30
112
30
112
130
102
52
72
68
8.5
2.5
15
54.5
104.5
15
2.5
16
112
60
5
86
52
60
30
90
60
22
24
84
50
68
61
45
724
90
8
30
5.5
83.5
85
170
12
3089
21
11
54
805454
97 127φ8.5
60
95
116
30
90
125
Connecting
allowance 15
Drilling plan
Breaker (plug-in terminal block)
M5 × 0.8 screw
or φ6 hole
20 max.
Conductor drilling drawingDetails of terminal
Plug-in terminal block
Mounting plate
M8 screw
M5 × 0.8 screw
Mounting with terminal block
mounting nut or mounting
directly with screw
Breaker
Drilling plan
M4 × 0.7 screw
or φ5 hole
3-pole
Trip
button
Operating time
changing unit
(time delay type)
4-pole
Neutral pole
Earth-leakage
indicating button
Test button
Sensitivity current
switching unit
Insulating barrier (removable)
Mounting hole
φ8.5
M8 screw
Conductor drilling
for direct connection
(Conductor thickness t = 5 max.)
φ8.5
φ4.5
Breaker
Insulating tube
M4 × 0.7 screw
for breaker
mounting
M4 × 0.7 screw or φ5 hole
Breaker
Drilling plan
Mounting plate
t = 3.2 max. Stud rotatable by 90°
Insulating tube
M8 bolt
Front-panel cutout
1.0 mm clearance on each side of the
handle frame
Remark: NV125-CV is available in 3-pole only.
Earth-leakage circuit breakers
New WS-V Series
NV125-CV, NV125-SV, NV125-HV
Front connection
Rear connection
Plug-in
3-pole
4-pole
3-pole
4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 19 −
21. Molded-case circuit breakers
Previous W & WS Series
NF250-CW, NF250-SW, NF250-HW,
MB225-SW
Front connection
Rear connection
Plug-in
105
102
50
61
68
45
724
92
24
70
22
23 max.
10
35
φ4.5
φ8.5
35
126
140
105
35
100100165
144
Neutral
pole
Breaker
M4 × 0.7 screw
or φ5 hole
Drilling plan
Mounting hole
Insulating barrier
(removable)
Trip
button
M8 bolt with
hexagon hole
φ8.5
CL
CLLC
CL CL
CL
Conductor drilling
for direct connection
(Conductor thickness t = 7 max.)
15
15
22
20
144
70
35
φ24
68
72
71
106
8
6
105
70
35
105
35
126
144
Drilling plan
M4 × 0.7
screw or
φ5 hole
Breaker
M4 × 0.7 screw
for breaker
mounting
Insulating tube
φ9
M8 bolt
Connecting
allowance
Insulating tube
Stud rotatable by 90°
Mounting plate
t = 3.2 max.
CL CL
LCLC
32.5
52
100
Breaker
LC
CL
CL
R
1
86
200
18
32
14434.528
20
70
105
153
6
14
70
107
70
15
22
φ7
58.558.580
54
142
105
Studs can be
installed in this
direction only.
Insulating barrier
M6 screw
for mounting
terminal block
Mounting plate Plug-in terminal block
Connecting
allowance
φ9
M8 bolt
Drilling plan
Breaker (plug-in terminal block)
CL CL
CL
CL
LC
3-pole 4-pole
3-pole 4-pole
Front-panel cutout
1.0 mm clearance on each side of the
handle frame
Remarks: 1. 2-pole models are 3-pole models with the central pole removed.
2. Only 2- and 3-pole models are available for the model of NF250-CW and only 3-pole models are available for the model of MB225-SW.
3-pole
4-pole
3-pole 4-pole
3-pole
4-pole
3-pole 4-pole
3-pole
4-pole
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 20 −
22. 105
102
50
61
68
45
724
92
24
70
22
25 max.
9
35
φ4.5
φ8.5
35
126
140
105
35
100100165
144
Neutral pole
Breaker
M4 × 0.7 screw
or φ5 hole
Drilling plan
Mounting hole
Insulating barrier
(removable)
Trip
button
M8 bolt with
hexagon hole
φ8.5
Conductor drilling
for direct connection
(Conductor thickness t = 7 max.)
15
15
22
20
144
70
35
φ24
68
72
71
106
8
6
105
70
105
35
126
144
Drilling plan
M4 × 0.7
screw or
φ5 hole
Breaker
M4 × 0.7 screw
for breaker
mounting
Insulating tubeφ9
M8 bolt
Connecting
allowance
Insulating tube
Stud rotatable by 90°Mounting plate
t = 3.2 max.
32.5
52
100
Breaker
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
R
1
89
112
190
165
21
30
31
14434.528
20
3-pole 70
4-pole 105
3-pole 105
4-pole 140
151
6
11
70
107
70
15
24
56.556.580
54
142
105
Studs can be installed
in this direction only.
Insulating barrier
Mounting plate
Plug-in terminal block
Connecting
allowance
φ9
M8 bolt
Drilling plan
Breaker (plug-in terminal block)
4-pole 145
3-pole 110
35
M5 × 0.8 screw
or φ6 hole
M5 screw
for mounting
terminal block
or
C
1
C
1
10
25 max.
φ8.5
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
Molded-case circuit breakers
New WS-V Series
NF250-CV, NF250-SV, NF250-HV
Front connection
Rear connection
Plug-in
3-pole
4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
3-pole
4-pole
3-pole 4-pole
Remarks: 1. 2-pole models are 3-pole models with the central pole removed.
2. Only 2- and 3-pole models are available for the model of NF250-CV.
− 21 −
23. Earth-leakage circuit breakers
Previous W & WS Series
NV250-CW, NV250-SW, NV250-HW
Front connection
Rear connection
Plug-in
Drilling plan
M4 × 0.7 screw or φ5 hole
Breaker
126
3535
LC
LC
LC
Test button
Operating time
changing unit
(time delay type)
Sensitivity current
switching unit
Earth-leakage indicating button
Test button
105
70
Insulating barrier
(removable)
Mounting
hole
Trip
button
Operating time
changing unit
(time delay type)
Sensitivity current
switching unit
Earth-leakage
indicating
button
Neutral
pole
144
165100100
35
105
140
LC
CL
LC
22
φ8.5
M8 bolt with
hexagon hole
φ8.5
φ4.5
10
24
92
4 72
45
68
61
50
102
23 max.
Conductor drilling
for direct connection
(Conductor thickness t = 7 max.)
Breaker
M4 × 0.7
screw or
φ5 hole
Drilling plan
144
126
35
105
35φ24
35
70
CL CL
LC
LC
Mounting plate
t = 3.2 max.
Stud rotatable by 90°
Insulating tube
φ9
M8 bolt
Insulating tube
M4 × 0.7 screw for
breaker mounting
70
105
6
8
106
71
72
68
144
20
Connecting
allowance 22
15
15
1.0 mm clearance on each side of the
handle frame
Breaker
100
52
32.5
LC
LC
CL
R
1
φ9
M8 bolt
Insulating barrier
Studs can be
installed in this
direction only.
15
70
153
70
105
20
LC Breaker (plug-in terminal block)
Drilling plan
105
142
54
8058.558.5
φ7
107
70
CLLC
LC
Plug-in terminal blockMounting plate
M6 screw
for mounting
terminal block
14
6
2834.5144
32
18
200
86
LC
4-pole
3-pole
Front-panel cutout
22Connecting
allowance
Remark: NV250-CW are available in 3-pole only.
3-pole
4-pole
3-pole
4-pole
3-pole 4-pole
3-pole
4-pole
3-pole 4-pole
3-pole 4-pole
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 22 −
24. 100
144
165
15
105
102
50
61
68
45
724
92
24
70
22
9
φ8.5
15
20
144
70
35
35
φ24
φ4.5
68
72
71
106
φ8.5
35
126
140
105
35
100100165
144
8
6
105
70
35
105
35
126
144 32.5
R
1
52
100
8056.556.5
107 142
34.528144
6
21
89
112
190
11
165
30
31
20
151
70
24Connecting
allowance
15
54
70 105
25 max.
Breaker
Breaker
Drilling plan
M4 × 0.7 screw or φ5 hole
Insulating tube
M4 × 0.7 screw
for breaker
mounting
Test button
Insulating barrier
(removable)Mounting hole
Trip
button
Operating time
changing unit
(time delay type)
Sensitivity current
switching unit
Earth-leakage
indicating button
Neutral pole
M8 bolt with
hexagon hole
Conductor drilling
for direct connection
(Conductor thickness t = 7 max.)
Mounting plate
t = 3.2 max.
Stud rotatable by 90°
Insulating
tube
φ9
M8 bolt
Connecting
allowance 22
M4 × 0.7
screw or
φ5 hole
M5 × 0.8 screw
or φ6 hole
Drilling plan Front-panel cutout
1.0 mm clearance on each side of the
handle frame
Breaker
Plug-in terminal block
Mounting plate
φ9
M8 bolt
Insulating barrier Studs can be installed
in this direction only.
4-pole 145
4-pole 105
3-pole 110
3-pole 70
4-pole 140
3-pole 105
Drilling plan
M5 screw
for mounting
terminal block
Remark: NV250-CV are available in 3-pole only.
Earth-leakage circuit breakers
New WS-V Series
NV250-CV, NV250-SV, NV250-HV
Front connection
Rear connection
Plug-in
3-pole
4-pole
3-pole 4-pole
3-pole
4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
or
C
1
C
1
10
25 max.
φ8.5
− 23 −
25. NV250-SEW, NV250-HEW
Front connection
Rear connection
Plug-in
Insulating barrier
22Connecting
allowance
15
153
20
70
105
70
φ9
M8 bolt
Studs can be installed
in this direction only.
Breaker (plug-in terminal block)
Drilling plan
Plug-in terminal block
Mounting plate
105
142
54
8058.558.5
φ7
107
70
14
6
2834.5144
32
18
200
86
(Note) To change the settings, open the upper cover.
Current indicating LED
OVER
PAL
70%
Overcurrent
test connector
(Conductor thickness t = 7 max.)
φ8.5
M8 bolt with
hexagon hole
Trip
button
Mounting hole
Drilling plan
Breaker
Neutral
pole
144
165100100
35
105
140
126
35
φ8.5
φ4.5
35
10
23 max.
22
70
24
92
4 72
45
68
61
50
102(Uppercover)
105
Earth-leakage
test button
Tripping characteristic
switching unit
Sensitivity current
switching unit
Earth-leakage indicating button
Operating time
changing unit
(time delay type)
Insulating barrier (removable)
M4 × 0.7 screw or φ5 hole
Conductor drilling
for direct connection
Breaker3-pole
4-pole
100
52
32.5
R1
Insulating tube
22 Connecting
allowance
φ9
M8 bolt Insulating tube
M4 × 0.7 screw
for breaker
mounting
Breaker
Drilling plan
144
126
35
105
35
70
105
6
8
106
71
72
68
φ24
35
70
144
20
15
15 M4 × 0.7
screw or
φ5 hole
Stud rotatable by 90°
Mounting plate
t = 3.2 max.
3-pole
4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
3-pole
4-pole
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
M6 screw
for mounting
terminal block
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
Earth-leakage circuit breakers
Previous W & WS Series
− 24 −
26. NV250-SEV, NV250-HEV
Front connection
Rear connection
Plug-in
165
165
100
144
144
100
Tripping
characteristic
switching unit
Test button
Sensitivity current
switching unit
Earth-leakage
indicating button
25 max.
M8 bolt with
hexagon hole
105
102
50
61
68
45
724
92
24
70
22
9
φ8.5
35
Mounting hole
(Conductor thickness t = 7 max.)
Breaker
φ4.5
φ8.5
35
126
140
105
35
100
Neutral pole
Trip
button
Operating time
changing unit
(time delay type)
Insulating barrier
(removable)
Conductor drilling
for direct connection Drilling plan
M4 × 0.7 screw or φ5 hole
Breaker
32.5
52
100
R1
Stud rotatable by 90°
15
15
20
144
70
35
Mounting plate
t = 3.2 max.
Insulating
tube
22 Connecting
allowance
φ9
M8 bolt
M4 × 0.7 screw
for breaker
mounting
φ24
68
72
71
106
Insulating tube
8
6
105
70
35
105
35
126
144
Breaker
Drilling plan
M4 × 0.7
screw or
φ5 hole
Front-panel cutout
4-pole 140
4-pole 105
8056.556.5
107 142
34.528144
6
21
89
112
190
11
165
30
31
20
3-pole 70
151
70
24Connecting
allowance
15
3-pole 105
54
70
Plug-in terminal block
Mounting plate
105
Insulating
barrier
M5 × 0.8 screw
or φ6 hole
φ9
M8 bolt
Studs can be installed
in this direction only.
4-pole 145
3-pole 110
M5 screw
for mounting
terminal block
3-pole
4-pole 3-pole
4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
Earth-leakage circuit breakers
New WS-V Series
or
C
1
C
1
10
25 max.
φ8.5
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 25 −
27. NF125-SGW, NF125-HGW, NF160-SGW, NF160-HGW,
NF250-SGW, NF250-HGW
Remark: 1. 2-pole models are 3-pole models with the central pole removed.
Mounting plate
4530
Stud can be
rotated 90°
545494
66
4-pole
3-pole
110
1048
103
M8 bolt
(Hex-soket)12
96
4
4854.5144
120
15
200
4-pole3-pole
φ9
M8 bolt
105
142
Drilling plan
Connection
allowance
Insulating barrier
(removable)
M6 screw
for mounting
terminal block
Breaker (Terminal block)
φ7
Plug-in terminal block
107
70
70
20
86
3-pole
4-pole
100
52
32.5
Breaker
Front-panel cutout
R
1
35
90
86
Breaker
4-pole3-pole
144
126
35
105
35
70
105
6
8
3-pole
4-pole
Insulating
tube
M4 × 0.7
taps
or φ5
Drilling plan
106
71
φ24
M4 × 0.7
screw for
breaker
mounting
φ9
M8 bolt
Connection
allowance
Insulating tube
Stud can be
rotated 90°
Mounting plate
t = 3.2 max.
70
144
20
22
15
15
Hex-socket set screw
Wire connection
Solderless terminal
for wire size
2.5 185 mm2
10
6.1
22
35
24 max.
110
90
86
79
63
112
4-pole3-pole
Neutral
pole
4-pole3-pole
144
1655050
35
105
140
126
35
φ8.5
φ4.5
M4 × 0.7 taps
or φ5
Drilling plan
Breaker
M8 bolt
(Hex-soket)
(Bus t max. = 7)
Bus drilling for
direct connection
Trip
button
Mounting hole
Insulating barrier
(removable)
φ8.5
10
22
70
24
450
105
Front connection
Rear connection
Plug-in
Molded-case circuit breakers
Previous W & WS Series
1.0 mm clearance on each side of the
handle frame
− 26 −
28. NF125-SGV, NF125-LGV, NF125-HGV, NF125-SEV, NF125-HEV,
NF160-SGV, NF160-LGV, NF160-HGV,
NF250-SGV, NF250-LGV, NF250-HGV, NF250-SEV, NF250-HEV
105
102
50
61
68
45
724
92
24
70
22
25 max.
9
35
φ4.5
φ8.5
35
126
140
105
35
100100165
144
Neutral pole
Breaker
M4 × 0.7 screw
or φ5 hole
Drilling plan
Mounting hole
Insulating barrier
(removable)
Trip
button
M8 bolt with
hexagon hole
φ8.5
Conductor drilling
for direct connection
(Conductor thickness t = 7 max.)
15
15
22
20
144
70
35
φ24
68
72
71
106
8
6
105
70
105
35
126
144
Drilling plan
M4 × 0.7
screw or
φ5 hole
Breaker
M4 × 0.7 screw
for breaker
mounting
Insulating tubeφ9
M8 bolt
Connecting
allowance
Insulating tube
Stud rotatable by 90°Mounting plate
t = 3.2 max.
32.5
52
100
Breaker
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
R
1
89
112
190
165
21
30
31
14434.528
20
3-pole 70
4-pole 105
3-pole 105
4-pole 140
151
6
11
70
107
70
15
24
56.556.580
54
142
105
Studs can be installed
in this direction only.
Insulating barrier
Mounting plate
Plug-in terminal block
Connecting
allowance
φ9
M8 bolt
Drilling plan
Breaker (plug-in terminal block)
4-pole 145
3-pole 110
35
M5 × 0.8 screw
or φ6 hole
M5 screw
for mounting
terminal block
Front connection
Rear connection
Plug-in
3-pole
4-pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
3-pole
4-pole
3-pole 4-pole
Molded-case circuit breakers
New WS-V Series
or
C
1
C
1
10
25 max.
φ8.5
Remark: 2-pole models are 3-pole models with the central pole removed.
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 27 −
29. NF125-RGW, NF250-RGW
Front connection
Rear connection
Plug-in
φ7
Drilling plan
Mounting plate
φ9
M8 bolt
275
34.521928
6
32
18
14
104
15
70
20
70
153
70
58.558.5155
129
107
100
32.5
52
4-pole
3-pole
R
1
Breaker
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
11.5
105
35
35
70
35
4-pole
3-pole
8
105
70
6
20
15
15
90 106
7186
4-pole3-pole
Insulating
tube
M4 × 0.7
taps
or φ5
Drilling plan
φ24
M4 × 0.7 screw
for breaker
mounting
φ9
M8 bolt
Connection
allowance
Insulating tube
Stud can be
rotated 90°
Mounting plate
t = 3.2 max.
201
219
219
108
73
22
Breaker
24
(Bus t max. = 7)
24 max.
10
M8 bolt
(Hex-soket)
M4 × 0.7 taps
or φ5
3535
110
4 90
86
79
φ8.5
63
22
φ4.5
50
112
4-pole
5050
35
105
140
22
70
105
4-pole3-pole
Neutral
pole
3-pole
Drilling plan
Breaker
Trip
button
Mounting hole
Insulating barrier
(removable)
201
240
219
φ8.5
6.1
Solderless terminal
for wire size
2.5 185 mm2
10
Bus drilling for
direct connection
Wire connection
Hex-socket set screw
26.5
75165
Remark: 2-pole models are 3-pole models with the central pole removed.
Molded-case circuit breakers
Previous W & WS Series
Plug-in terminal block
M6 screw
for mounting
terminal block
Breaker (Terminal block)
Insulating
barrier
Stud attachable in this
derection only
22
Connecting
allowance
− 28 −
30. Molded-case circuit breakers
New WS-V Series
NF125-RGV, NF250-RGV
15
15
22
20
144
70
35
φ24
68
72
71
106
8
6
70
Drilling plan
M4 × 0.7
screw or
φ5 hole
Breaker
M4 × 0.7 screw
for breaker
mounting
Insulating tubeφ9
M8 bolt
Connecting
allowance
Insulating tube
Stud rotatable by 90°Mounting plate
t = 3.2 max.
32.5
52
100
Breaker
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
R
1
Front connection
Rear connection
Plug-in
3-pole
3-pole
70
107
Drilling plan
Breaker (plug-in terminal block)
3-pole
105
70
22
Mounting hole
Insulating barrier
(removable)
Trip
button
3-pole
3-pole
35
Breaker
M4 × 0.7 screw
or φ5 hole
Drilling plan
3-pole
102
50
61
68
45
724
92
24
25 max.
9
φ4.5
φ8.5
M8 bolt with
hexagon hole
φ8.5
Conductor drilling
for direct connection
(Conductor thickness t = 7 max.)
or
C
1
C
1
10
25 max.
φ8.5
89
112
190
165
21
30
31
14434.528
6
11
Mounting plate
Plug-in terminal block
M5 screw
for mounting
terminal block
20
3-pole 70
3-pole 105
151
70
15
24
Studs can be installed
in this direction only.
Insulating barrier
Connecting
allowance
φ9
M8 bolt
3-pole 110
Remark: 2-pole models are 3-pole models with the central pole removed.
Solderless terminal for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 29 −
31. NF125-UGW, NF250-UGW
Front connection
Rear connection
Plug-in
φ7
Drilling plan
Mounting plate
φ9
M8 bolt
275
34.521928
6
32
18
14
104
15
70
20
70
153
70
58.558.5155
129
107
100
32.5
52
4-pole
3-pole
R
1
Breaker
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
11.5
105
35
35
70
35
4-pole
3-pole
8
105
70
6
20
15
15
90 106
7186
4-pole3-pole
Insulating
tube
M4 × 0.7
taps
or φ5
Drilling plan
φ24
M4 × 0.7 screw
for breaker
mounting
φ9
M8 bolt
Connection
allowance
Insulating tube
Stud can be
rotated 90°
Mounting plate
t = 3.2 max.
201
219
219
108
73
22
Breaker
24
(Bus t max. = 7)
24 max.
10
M8 bolt
(Hex-soket)
M4 × 0.7 taps
or φ5
3535
110
4 90
86
79
φ8.5
63
22
φ4.5
50
112
4-pole
5050
35
105
140
22
70
105
4-pole3-pole
Neutral
pole
3-pole
Drilling plan
Breaker
Trip
button
Mounting hole
Insulating barrier
(removable)
201
240
219
φ8.5
6.1
Solderless terminal
for wire size
2.5 185 mm2
10
Bus drilling for
direct connection
Wire connection
Hex-socket set screw
26.5
75165
Remark: 2-pole models are 3-pole models with the central pole removed.
Molded-case circuit breakers
Previous W & WS Series
Plug-in terminal block
M6 screw
for mounting
terminal block
Breaker (Terminal block)
Insulating
barrier
Stud attachable in this
derection only
22
Connecting
allowance
− 30 −
32. 106
71
72
68
8
6
105
70
20
22
15
15
219
φ24 35
105
35
70
32.5
52
10035
219
201
11.5
35
201
35
92
4 72
68
61
45
φ4.5
50
102
24
100100240
219
140
105
35
105
70
22
75165
10
φ8.5
φ8.5
28
75165
73
108
Breaker
Drilling plan
M4 × 0.7 screw or φ5 hole
23 max.
Insulating barrier
(removable)
Mounting hole
Trip button
Conductor drilling
for direct connection
(Conductor thickness t = 7 max.)
M4 × 0.7 screw
or φ5 hole
Drilling plan
Breaker
3-pole
M4 × 0.7 screw
for breaker
mounting
Insulating tube
φ9
M8 bolt
Connecting
allowance
Insulating
tube Stud rotatable by 90°
Mounting plate
t = 3.2 max. Breaker
3-pole
4-pole
1.0 mm clearance on each side of the
handle frame
Front-panel cutout
R1
Breaker
(plug-in terminal block)
Mounting plate
Plug-in terminal block
Studs can be installed
in this direction only.
Insulating barrier
Connecting
allowance
15556.556.5
107
34.528219
6
21
89
11
30
31
20
70
151
70
24
15
110
105
129
70
φ9
M8 bolt M5 screw or φ6 hole
265
Drilling plan
Molded-case circuit breakers
New WS-V Series
NF125-UGV, NF250-UGV
Front connection
Rear connection
Plug-in
Neutral pole
3-pole 4-pole
3-pole 4-pole
3-pole 4-pole
M8 bolt with
hexagon hole
4-pole
M5 screw
for mounting
terminal block
Remark: 2-pole models are 3-pole models with the central pole removed.
Solderless terminal
for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
− 31 −
35. Revised publication, effective Sep. 2010.
Specifications subject to change without notice.
This pamphlet is made from recycled paper.
Safety Tips : Be sure to read the instruction manual fully before using this product.
Country / Region Company Address Telephone
Australia
China
Mitsubishi Electric Australia Pty. Ltd.
Mitsubishi Electric Automation (CHINA) Ltd.
348 Victoria Road, Rydalmere, N.S.W. 2116, Australia +61-2-9684-7777
+86-21-2322-3030
17/F., ChuangXing Financial Center,
No.288 West Nanjing Road, Shanghai, 200003
China Mitsubishi Electric Automation (HongKong) Ltd. +852-2887-8810
10/F., Manulife Tower, 169 Electric Road, North Point,
Hong Kong
Colombia Proelectrico Representaciones S.A. Carrera 53 No 29C-73 - Medellin, Colombia +57-4-235-30-38
Egypt Cairo Electrical Group
9, Rostoum St. Garden City P.O. Box 165-11516
Maglis El-Shaab, Cairo - Egypt
+20-2-27961337
Europe Mitsubishi Electric Europe B.V. Gothaer Strasse 8, D-40880 Ratingen, Germany +49-(0)2102-486-0
Indonesia
Korea
Laos
Mitsubishi Electric Automation Korea Co., Ltd
Societe Lao Import Co., Ltd.
P.O.Box 5045 Kawasan Industri Pergudangan,
Jakarta, Indonesia
1480-6, Gayang-Dong, Gangseo-Gu, Seoul, Korea
43-47 Lane Xang Road P.O. BOX 2789 VT Vientiane Laos
+62-(0)21-6610651-9
+82-2-3660-9572
+856-21-215043
P. T. Sahabat Indonesia
Lebanon Comptoir d'Electricite Generale-Liban
Cebaco Center - Block A Autostrade Dora,
P.O. Box 11-2597 Beirut - Lebanon
+961-1-240445
Myanmer
Nepal
Peace Myanmar Electric Co.,Ltd.
Watt&Volt House
NO137/139 Botataung Pagoda Road,
Botataung Town Ship 11161, Yangon, Myanmar
KHA 2-65, Volt House Dillibazar Post Box:2108,
Kathmandu, Nepal
Malaysia Mittric Sdn Bhd
5 Jalan Pemberita U1/49, Temasya Industrial Park,
Glenmarie 40150 Shah Alam, Selangor, Malaysia
+603-5569-3748
+95-(0)1-202589
+977-1-4411330
Comptoir d'Electricite
Generale-International-S.A.L.
Cebaco Center - Block A Autostrade Dora
P.O. Box 11-1314 Beirut - Lebanon
+961-1-240430
Other Middle East
Arab Countries & Cyprus
Pakistan
Philippines
Prince Electric Co.
Edison Electric Integrated, Inc.
1&16 Brandreth Road, Lahore-54000, Pakistan
24th Fl. Galleria Corporate Center, Edsa Cr. Ortigas Ave.,
Quezon City Metro Manila, Philippines
+92-(0)42-7654342
+63-(0)2-634-8691
Saudi Arabia Center of Electrical Goods
Al-Shuwayer St. Side way of Salahuddin Al-Ayoubi St.
P.O. Box 15955 Riyadh 11454 - Saudi Arabia
+966-1-4770149
South Africa CBI-electric: low voltage Private Bag 2016, Isando, 1600, South Africa +27-(0)11-9282000
Taiwan
Thailand
Setsuyo Enterprise Co., Ltd
United Trading & Import Co., Ltd.
6th Fl., No.105, Wu Kung 3rd, Wu-Ku Hsiang,
Taipei, Taiwan, R.O.C.
77/12 Bamrungmuang Road, Klong Mahanak,
Pomprab Bangkok Thailand
+886-(0)2-2298-8889
+66-223-4220-3
Uruguay Fierro Vignoli S.A. Avda. Uruguay 1274, Montevideo, Uruguay +598-2-902-0808
Venezuela Adesco S.A.
Calle 7 La Urbina Edificio Los Robles Locales C y D
Planta Baja, Caracas - Venezuela
+58-212-241-9952
Chile Rhona S.A. Agua Santa 4211 P.O. Box 30-D Vina del Mar, Chile +56-32-2-320-600
Vietnam CTY TNHH-TM SA GIANG
10th Floor, Room1006-1007,225 Tran Hung Dao St.,
Co Giang Ward, Dist.1, Ho Chi Minh City. Viet Nam
+84-8-838-6727/28/29
Singapore Mitsubishi Electric Asia Pte. Ltd.
307, Alexandra Road, #05-01/02
Mitsubishi Electric Building, Singapore 159943
+65-6473-2308
Y-0702 1009 printed in Japan(MDOC)
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
WS-V series Comparison of Previous and New Models