SlideShare a Scribd company logo
1 of 3
Download to read offline
Americas EMC Capabilities
                       Semi-anechoic      Emissions Test
                                                               Frequency Range                          Electrical Power
   Location              Chambers          Sites (OATs)                                                                                             Load
                      3m    10m   30m    3m    10m   30m    Emissions    Immunity           DC                 50Hz              60Hz
                                                                            DC to
Boxborough,                                                   20Hz to      40GHz         0-30V 100A          230V, 400V    120/208/240V 100A     Chambers - 4T
MA                     █     █                  █             220GHz        Up to         0-60V 50A             100A         277/480V 100A        OATS – 2T
                                                                          200 V/m
                                                                          10kHz to
                                                                                        0-30 V, 120 A
                                                              20Hz to      18GHz                             230 V, 50 A   120/208/240 V, 60 A
Duluth, GA             █     █                                40GHz         Up to
                                                                                         0-60 V, 50 A
                                                                                                             400 V, 50 A       480V, 60 A
                                                                                                                                                      4T
                                                                                          50V, 100A
                                                                           20 V/m
                                                                          20Hz to
Grand Rapids,                                                 20Hz to      18GHz                             230 V, 16 A   120/208/240V 100A
MI                    █a                                      40GHz         Up to
                                                                                       0-400 V, 0-50A
                                                                                                             400 V, 16 A     277/480V 100A
                                                                                                                                                      1T
                                                                          200 V/m
                                                                          10KHZ-                                            120/208/240/480V;
Lake Forest, CA        █                                    9kHa-40GHz    2.7GHz        0-80VDC, 50A     230/400V, 50A     100/100/60/100A/per        4T
                                                                         Up to 3 V/m                                             phase.
                                                                          10 kHz –
                                                                                        0-48V, 170 A
                                                              20Hz –       18GHz                            0-240 V          120/208/480 V
Lexington, KY          █     █                                40GHz         Up to
                                                                                        0-80 V, 25 A
                                                                                                         12 kVA/phase         100 A/phase
                                                                                                                                                      4T
                                                                                        0-400 V, 2 A
                                                                           10 V/m
                                                                          30 Hz to
                                                                                                              90 - 240V        90 - 240V
                                                              30Hz to      18GHz
Louisville CO          █                                      40GHz         Up to
                                                                                         0-50 V, 25A         100 A phase      100 A phase             1T
                                                                           10 V/m
                                                                          30 Hz –
                                                                                                                              480V, 208V,
                                                              20 Hz –     18 GHz                             380V, 230V,
Menlo Park, CA         █     █                                40 GHz       Up to
                                                                                          48V, 60A
                                                                                                                60A
                                                                                                                                 120V,                4T
                                                                                                                                  60A
                                                                          20 V/m
                                                                          10 kHz-
                                                                                                                            120/208/240/480V;
                                                                          18GHz
Oakdale, MN            █                  █     █     █     9kHz-40GHz
                                                                           Up to
                                                                                        0-80VDC, 50A     230/380V, 100A    100/100/60/100A/per        8T
                                                                                                                                 phase.
                                                                          10 V/m
                                                                          10KHZ-
                                                                                                                            120/208/240/480V;
                                                                           4GHz
Plano, TX              █                                    9kHz-26GHz
                                                                           Up to
                                                                                        0-50VDC, 50A     230/380V, 100A    100/100/60/100A/per        2T
                                                                                                                                 phase.
                                                                          10 V/m

             Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS)
             █ a.   Grand Rapids also has a Reverb Chamber capable of immunity test levels up to 200 V/m +
Asia Pacific EMC Capabilities
                    Emissions or
                                        Emissions Test
                     Immunity                                         Frequency Range                            Electrical Power
  Location                               Sites (OATs)                                                                                                 Load
                     Chambers
                   3m    10m 30m        3m     10m 30m           Emissions            Immunity         DC            50Hz                60Hz

Hong Kong         █a                    █                         9k to 40 GHz       150k to 3GHz      24V
                                                                                                                    100-240V           100-240V
                                        x2                                                                            13A                13A

                                                                                                                                                      800kg
Shanghai (ETL                                                                                         12–72V       100–240V            100–240V
SEMKO)            █ x2                                           9k to 26.5 GHz      150k to 3.2GHz
                                                                                                       100A           25A                 25A

                                       █ x3 █ x3 █ x2
Kashima           █ x2   █                                        9k to 40 GHz       10k to 18GHz               100-240V/20kVA       100-240V/17kVA   10T
                                        █       █       █

Matsuda           █ x2                 █ x5 █ x5                  9k to 40GHz        10k to 18GHz               100-240V/15kVA       100-240V/15kVA    5T


                                                                                            80 to
Nagano             █                   █ x3 █ x3                  9k to 40GHz
                                                                                          1000MHz
                                                                                                                 100-240V/6kVA       100-240V/6kVA     1T


Tochigi                                █ x3 █ x3                  9k to 40GHz                                    100-240V/6kVA       100-240V/6kVA     5T


                  █ x2                                                                                 48V          100-240V           100-240V
Shenzhen                                                          9k to 18GHz        150k to 3GHz       3A                                             1T
                                                                                                                      16A                16A


Taiwan            █ x2                                            9k to 40GHz        150k to 3GHz
                                                                                                      12–48V       100–240V            110–230V
                                                                                                                                                      200kg
                                                                                                        30A           25A                 25A


                             2 shield rooms for conducted emissions, power disturbance,                        0-240V single phase       0-120V
Guangzhou
                                        magnetic emissions, and immunity tests                                 0-380V three phases    single phase


            Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS)
            █   a. Full anechoic chamber used in Hong Kong for Immunity only
European EMC Capabilities
                     Semi-anechoic       Emissions Test
                                                               Frequency Range                          Electrical Power
                       Chambers           Sites (OATs)
     Location                                                                                                                                Load
                             10    30            10   30
                     3m                  3m                Emissions       Immunity          DC             50Hz               60Hz
                             m     m             m    m
                                                                                            0-300V
Italy                                                                       150kHz to                      240V-22A           240V-22A
                     █a                   █      █         9kHz to 18GHz
                                                                             4.2GHz
                                                                                             16A,
                                                                                                           320V-16A           320V-16A
                                                                                                                                              1T
                                                                                          0-80V 30A
                                                                                                                            0-135V, 37A
                                                           20 Hz to 26.5   10 kHz to 3
Finland               █                                        GHz            GHz
                                                                                          0-120V, 13A   100 – 690V, 63A                       4T
                                                                                                                           135 – 270V, 18A
                                                                                                                               0-440 V
                                                           9 kHz to 26.5   150 kHz to 4     0-150 V         0-440 V
Germany             █ x2                  █      █             GHz             GHz            50 A      130 A per phase
                                                                                                                                110A          2T
                                                                                                                              per phase

                                                              20Hz to       10kHz to        0-54V          100-240V           100-240V
Sweden                █      █            █      █            40GHz          18GHz          200A             63A                16A
                                                                                                                                              6T


                                                              20Hz to        20Hz to        0-100V         0-415V              0-110V
UK                  █ 5m                  █      █            40GHz          18GHz           200A       150A per phase           16A
                                                                                                                                              3T


           Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS)
           █ a.   Italy: full anechoic chamber

More Related Content

What's hot (18)

Mean well rs-150
Mean well   rs-150Mean well   rs-150
Mean well rs-150
 
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...
 
En25861864
En25861864En25861864
En25861864
 
Datasheet of IDH10SG60C
Datasheet of IDH10SG60CDatasheet of IDH10SG60C
Datasheet of IDH10SG60C
 
Raycmltv
RaycmltvRaycmltv
Raycmltv
 
Datasheet of 2SK2287
Datasheet of 2SK2287Datasheet of 2SK2287
Datasheet of 2SK2287
 
Cd4093 bc
Cd4093 bcCd4093 bc
Cd4093 bc
 
Lsa47.2
Lsa47.2Lsa47.2
Lsa47.2
 
Rkb650 fiche produit
Rkb650 fiche produitRkb650 fiche produit
Rkb650 fiche produit
 
Datasheet of 2SJ374
Datasheet of 2SJ374Datasheet of 2SJ374
Datasheet of 2SJ374
 
Mean well net-75 triple out
Mean well   net-75 triple outMean well   net-75 triple out
Mean well net-75 triple out
 
220k V Cable Ac Test Solution
220k V Cable Ac Test Solution220k V Cable Ac Test Solution
220k V Cable Ac Test Solution
 
Vx 402
Vx 402Vx 402
Vx 402
 
Rkb250 fiche produit
Rkb250 fiche produitRkb250 fiche produit
Rkb250 fiche produit
 
9500+ datasheet
9500+ datasheet9500+ datasheet
9500+ datasheet
 
May 26-31, 2011 INS Conference Presentation
May 26-31, 2011 INS Conference PresentationMay 26-31, 2011 INS Conference Presentation
May 26-31, 2011 INS Conference Presentation
 
Outback Power Backup Systems
Outback Power Backup SystemsOutback Power Backup Systems
Outback Power Backup Systems
 
acarlen
acarlenacarlen
acarlen
 

Similar to Intertek emc capabilities

Latest Developments in 790nm-pumped Tm-doped Fiber Laser Systems for DIRCM Ap...
Latest Developments in 790nm-pumped Tm-doped Fiber Laser Systems for DIRCM Ap...Latest Developments in 790nm-pumped Tm-doped Fiber Laser Systems for DIRCM Ap...
Latest Developments in 790nm-pumped Tm-doped Fiber Laser Systems for DIRCM Ap...nufchas
 
In Win-Commander Series Power Supply
In Win-Commander Series Power SupplyIn Win-Commander Series Power Supply
In Win-Commander Series Power Supplyinwin
 
PC Board Relays - 26 Series
PC Board Relays - 26 SeriesPC Board Relays - 26 Series
PC Board Relays - 26 SeriesWerner Electric
 
Satronix Pvt. Ltd., Mumbai, Power Electronics Products
Satronix  Pvt. Ltd., Mumbai, Power Electronics ProductsSatronix  Pvt. Ltd., Mumbai, Power Electronics Products
Satronix Pvt. Ltd., Mumbai, Power Electronics ProductsIndiaMART InterMESH Limited
 
Legend Power Technical Brochure
Legend Power Technical BrochureLegend Power Technical Brochure
Legend Power Technical BrochureLegend Power
 
General Purpose Relays - Werner Electric
General Purpose Relays - Werner ElectricGeneral Purpose Relays - Werner Electric
General Purpose Relays - Werner ElectricWerner Electric
 
Datavideo PD-1
Datavideo PD-1Datavideo PD-1
Datavideo PD-1AVNed
 
30930100 allen-bradley
30930100 allen-bradley30930100 allen-bradley
30930100 allen-bradleyalimoya13
 
Problemas del Laboratorio N°1 de Física II
Problemas del Laboratorio N°1 de Física IIProblemas del Laboratorio N°1 de Física II
Problemas del Laboratorio N°1 de Física IIguestf39ed9c1
 
Problemas (10 Págs. - 42 Probl.) del Laboratorio N° 1 de Física II
Problemas (10 Págs. - 42 Probl.) del Laboratorio N° 1 de Física IIProblemas (10 Págs. - 42 Probl.) del Laboratorio N° 1 de Física II
Problemas (10 Págs. - 42 Probl.) del Laboratorio N° 1 de Física IILUIS POWELL
 
1st cycle emec lab orientation
1st cycle emec lab orientation1st cycle emec lab orientation
1st cycle emec lab orientationsoumendu
 
Power Relays - Werner Electric
Power Relays - Werner ElectricPower Relays - Werner Electric
Power Relays - Werner ElectricWerner Electric
 
PROBLEMAS RESUELTOS (42) DE LABORATORIO N° 1 DE FÍSICA II - TIPPENS
PROBLEMAS RESUELTOS (42) DE LABORATORIO N° 1 DE FÍSICA II - TIPPENSPROBLEMAS RESUELTOS (42) DE LABORATORIO N° 1 DE FÍSICA II - TIPPENS
PROBLEMAS RESUELTOS (42) DE LABORATORIO N° 1 DE FÍSICA II - TIPPENSLUIS POWELL
 
Digital module simatic s7 400
Digital module simatic s7 400Digital module simatic s7 400
Digital module simatic s7 400Taufiq Wibowo
 

Similar to Intertek emc capabilities (20)

Latest Developments in 790nm-pumped Tm-doped Fiber Laser Systems for DIRCM Ap...
Latest Developments in 790nm-pumped Tm-doped Fiber Laser Systems for DIRCM Ap...Latest Developments in 790nm-pumped Tm-doped Fiber Laser Systems for DIRCM Ap...
Latest Developments in 790nm-pumped Tm-doped Fiber Laser Systems for DIRCM Ap...
 
In Win-Commander Series Power Supply
In Win-Commander Series Power SupplyIn Win-Commander Series Power Supply
In Win-Commander Series Power Supply
 
PC Board Relays - 26 Series
PC Board Relays - 26 SeriesPC Board Relays - 26 Series
PC Board Relays - 26 Series
 
Satronix Pvt. Ltd., Mumbai, Power Electronics Products
Satronix  Pvt. Ltd., Mumbai, Power Electronics ProductsSatronix  Pvt. Ltd., Mumbai, Power Electronics Products
Satronix Pvt. Ltd., Mumbai, Power Electronics Products
 
Legend Power Technical Brochure
Legend Power Technical BrochureLegend Power Technical Brochure
Legend Power Technical Brochure
 
General Purpose Relays - Werner Electric
General Purpose Relays - Werner ElectricGeneral Purpose Relays - Werner Electric
General Purpose Relays - Werner Electric
 
46584589 substation-design-data
46584589 substation-design-data46584589 substation-design-data
46584589 substation-design-data
 
Datavideo PD-1
Datavideo PD-1Datavideo PD-1
Datavideo PD-1
 
1 n4007
1 n40071 n4007
1 n4007
 
30930100 allen-bradley
30930100 allen-bradley30930100 allen-bradley
30930100 allen-bradley
 
Ultra Slim Relays
Ultra Slim RelaysUltra Slim Relays
Ultra Slim Relays
 
Problemas del Laboratorio N°1 de Física II
Problemas del Laboratorio N°1 de Física IIProblemas del Laboratorio N°1 de Física II
Problemas del Laboratorio N°1 de Física II
 
Problemas (10 Págs. - 42 Probl.) del Laboratorio N° 1 de Física II
Problemas (10 Págs. - 42 Probl.) del Laboratorio N° 1 de Física IIProblemas (10 Págs. - 42 Probl.) del Laboratorio N° 1 de Física II
Problemas (10 Págs. - 42 Probl.) del Laboratorio N° 1 de Física II
 
Lsa47.2
Lsa47.2Lsa47.2
Lsa47.2
 
1st cycle emec lab orientation
1st cycle emec lab orientation1st cycle emec lab orientation
1st cycle emec lab orientation
 
Power Relays - Werner Electric
Power Relays - Werner ElectricPower Relays - Werner Electric
Power Relays - Werner Electric
 
Anschp27
Anschp27Anschp27
Anschp27
 
PROBLEMAS RESUELTOS (42) DE LABORATORIO N° 1 DE FÍSICA II - TIPPENS
PROBLEMAS RESUELTOS (42) DE LABORATORIO N° 1 DE FÍSICA II - TIPPENSPROBLEMAS RESUELTOS (42) DE LABORATORIO N° 1 DE FÍSICA II - TIPPENS
PROBLEMAS RESUELTOS (42) DE LABORATORIO N° 1 DE FÍSICA II - TIPPENS
 
Influence of capacity
Influence of capacityInfluence of capacity
Influence of capacity
 
Digital module simatic s7 400
Digital module simatic s7 400Digital module simatic s7 400
Digital module simatic s7 400
 

More from Intertek CE

CE Presentation
CE Presentation CE Presentation
CE Presentation Intertek CE
 
EMC Testing brochure
EMC Testing brochureEMC Testing brochure
EMC Testing brochureIntertek CE
 
Emc testing-brochure
Emc testing-brochureEmc testing-brochure
Emc testing-brochureIntertek CE
 
ETL Mark Fact-sheet
ETL Mark Fact-sheetETL Mark Fact-sheet
ETL Mark Fact-sheetIntertek CE
 
Hvac single-sheet-brochure
Hvac single-sheet-brochureHvac single-sheet-brochure
Hvac single-sheet-brochureIntertek CE
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilitiesIntertek CE
 
E uv usexplosiveareas
E uv usexplosiveareasE uv usexplosiveareas
E uv usexplosiveareasIntertek CE
 
Eu p power_supplies_im_final
Eu p power_supplies_im_finalEu p power_supplies_im_final
Eu p power_supplies_im_finalIntertek CE
 
Er p directive-televisions
Er p directive-televisionsEr p directive-televisions
Er p directive-televisionsIntertek CE
 
Ems pre reg_tips
Ems pre reg_tipsEms pre reg_tips
Ems pre reg_tipsIntertek CE
 
Emc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsEmc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsIntertek CE
 
Effects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsEffects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsIntertek CE
 
Eco design directive
Eco design directiveEco design directive
Eco design directiveIntertek CE
 
Door testing 10_steps
Door testing 10_stepsDoor testing 10_steps
Door testing 10_stepsIntertek CE
 

More from Intertek CE (20)

CE Presentation
CE Presentation CE Presentation
CE Presentation
 
EMC Testing brochure
EMC Testing brochureEMC Testing brochure
EMC Testing brochure
 
Emc testing-brochure
Emc testing-brochureEmc testing-brochure
Emc testing-brochure
 
ETL Mark Fact-sheet
ETL Mark Fact-sheetETL Mark Fact-sheet
ETL Mark Fact-sheet
 
Hvac single-sheet-brochure
Hvac single-sheet-brochureHvac single-sheet-brochure
Hvac single-sheet-brochure
 
Hvac brochure
Hvac brochureHvac brochure
Hvac brochure
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilities
 
S mark-en
S mark-enS mark-en
S mark-en
 
Intertek gs en
Intertek gs enIntertek gs en
Intertek gs en
 
Etl vs-ul-chart
Etl vs-ul-chartEtl vs-ul-chart
Etl vs-ul-chart
 
Wh mark
Wh markWh mark
Wh mark
 
E uv usexplosiveareas
E uv usexplosiveareasE uv usexplosiveareas
E uv usexplosiveareas
 
Eu p power_supplies_im_final
Eu p power_supplies_im_finalEu p power_supplies_im_final
Eu p power_supplies_im_final
 
Er p directive-televisions
Er p directive-televisionsEr p directive-televisions
Er p directive-televisions
 
Ems pre reg_tips
Ems pre reg_tipsEms pre reg_tips
Ems pre reg_tips
 
Emc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsEmc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systems
 
Emc safety
Emc safetyEmc safety
Emc safety
 
Effects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsEffects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designs
 
Eco design directive
Eco design directiveEco design directive
Eco design directive
 
Door testing 10_steps
Door testing 10_stepsDoor testing 10_steps
Door testing 10_steps
 

Recently uploaded

Future Of Sample Report 2024 | Redacted Version
Future Of Sample Report 2024 | Redacted VersionFuture Of Sample Report 2024 | Redacted Version
Future Of Sample Report 2024 | Redacted VersionMintel Group
 
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort ServiceCall US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Servicecallgirls2057
 
Call Us 📲8800102216📞 Call Girls In DLF City Gurgaon
Call Us 📲8800102216📞 Call Girls In DLF City GurgaonCall Us 📲8800102216📞 Call Girls In DLF City Gurgaon
Call Us 📲8800102216📞 Call Girls In DLF City Gurgaoncallgirls2057
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadAyesha Khan
 
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...ictsugar
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfpollardmorgan
 
Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessSeta Wicaksana
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607dollysharma2066
 
NewBase 19 April 2024 Energy News issue - 1717 by Khaled Al Awadi.pdf
NewBase  19 April  2024  Energy News issue - 1717 by Khaled Al Awadi.pdfNewBase  19 April  2024  Energy News issue - 1717 by Khaled Al Awadi.pdf
NewBase 19 April 2024 Energy News issue - 1717 by Khaled Al Awadi.pdfKhaled Al Awadi
 
Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Seta Wicaksana
 
Digital Transformation in the PLM domain - distrib.pdf
Digital Transformation in the PLM domain - distrib.pdfDigital Transformation in the PLM domain - distrib.pdf
Digital Transformation in the PLM domain - distrib.pdfJos Voskuil
 
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCRashishs7044
 
Buy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy Verified Accounts
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024christinemoorman
 
Marketplace and Quality Assurance Presentation - Vincent Chirchir
Marketplace and Quality Assurance Presentation - Vincent ChirchirMarketplace and Quality Assurance Presentation - Vincent Chirchir
Marketplace and Quality Assurance Presentation - Vincent Chirchirictsugar
 
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCRashishs7044
 
Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Riya Pathan
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...lizamodels9
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation SlidesKeppelCorporation
 
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607dollysharma2066
 

Recently uploaded (20)

Future Of Sample Report 2024 | Redacted Version
Future Of Sample Report 2024 | Redacted VersionFuture Of Sample Report 2024 | Redacted Version
Future Of Sample Report 2024 | Redacted Version
 
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort ServiceCall US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
 
Call Us 📲8800102216📞 Call Girls In DLF City Gurgaon
Call Us 📲8800102216📞 Call Girls In DLF City GurgaonCall Us 📲8800102216📞 Call Girls In DLF City Gurgaon
Call Us 📲8800102216📞 Call Girls In DLF City Gurgaon
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
 
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...Global Scenario On Sustainable  and Resilient Coconut Industry by Dr. Jelfina...
Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
 
Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful Business
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
 
NewBase 19 April 2024 Energy News issue - 1717 by Khaled Al Awadi.pdf
NewBase  19 April  2024  Energy News issue - 1717 by Khaled Al Awadi.pdfNewBase  19 April  2024  Energy News issue - 1717 by Khaled Al Awadi.pdf
NewBase 19 April 2024 Energy News issue - 1717 by Khaled Al Awadi.pdf
 
Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...
 
Digital Transformation in the PLM domain - distrib.pdf
Digital Transformation in the PLM domain - distrib.pdfDigital Transformation in the PLM domain - distrib.pdf
Digital Transformation in the PLM domain - distrib.pdf
 
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
 
Buy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail Accounts
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024
 
Marketplace and Quality Assurance Presentation - Vincent Chirchir
Marketplace and Quality Assurance Presentation - Vincent ChirchirMarketplace and Quality Assurance Presentation - Vincent Chirchir
Marketplace and Quality Assurance Presentation - Vincent Chirchir
 
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
 
Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
 
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
 

Intertek emc capabilities

  • 1. Americas EMC Capabilities Semi-anechoic Emissions Test Frequency Range Electrical Power Location Chambers Sites (OATs) Load 3m 10m 30m 3m 10m 30m Emissions Immunity DC 50Hz 60Hz DC to Boxborough, 20Hz to 40GHz 0-30V 100A 230V, 400V 120/208/240V 100A Chambers - 4T MA █ █ █ 220GHz Up to 0-60V 50A 100A 277/480V 100A OATS – 2T 200 V/m 10kHz to 0-30 V, 120 A 20Hz to 18GHz 230 V, 50 A 120/208/240 V, 60 A Duluth, GA █ █ 40GHz Up to 0-60 V, 50 A 400 V, 50 A 480V, 60 A 4T 50V, 100A 20 V/m 20Hz to Grand Rapids, 20Hz to 18GHz 230 V, 16 A 120/208/240V 100A MI █a 40GHz Up to 0-400 V, 0-50A 400 V, 16 A 277/480V 100A 1T 200 V/m 10KHZ- 120/208/240/480V; Lake Forest, CA █ 9kHa-40GHz 2.7GHz 0-80VDC, 50A 230/400V, 50A 100/100/60/100A/per 4T Up to 3 V/m phase. 10 kHz – 0-48V, 170 A 20Hz – 18GHz 0-240 V 120/208/480 V Lexington, KY █ █ 40GHz Up to 0-80 V, 25 A 12 kVA/phase 100 A/phase 4T 0-400 V, 2 A 10 V/m 30 Hz to 90 - 240V 90 - 240V 30Hz to 18GHz Louisville CO █ 40GHz Up to 0-50 V, 25A 100 A phase 100 A phase 1T 10 V/m 30 Hz – 480V, 208V, 20 Hz – 18 GHz 380V, 230V, Menlo Park, CA █ █ 40 GHz Up to 48V, 60A 60A 120V, 4T 60A 20 V/m 10 kHz- 120/208/240/480V; 18GHz Oakdale, MN █ █ █ █ 9kHz-40GHz Up to 0-80VDC, 50A 230/380V, 100A 100/100/60/100A/per 8T phase. 10 V/m 10KHZ- 120/208/240/480V; 4GHz Plano, TX █ 9kHz-26GHz Up to 0-50VDC, 50A 230/380V, 100A 100/100/60/100A/per 2T phase. 10 V/m Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS) █ a. Grand Rapids also has a Reverb Chamber capable of immunity test levels up to 200 V/m +
  • 2. Asia Pacific EMC Capabilities Emissions or Emissions Test Immunity Frequency Range Electrical Power Location Sites (OATs) Load Chambers 3m 10m 30m 3m 10m 30m Emissions Immunity DC 50Hz 60Hz Hong Kong █a █ 9k to 40 GHz 150k to 3GHz 24V 100-240V 100-240V x2 13A 13A 800kg Shanghai (ETL 12–72V 100–240V 100–240V SEMKO) █ x2 9k to 26.5 GHz 150k to 3.2GHz 100A 25A 25A █ x3 █ x3 █ x2 Kashima █ x2 █ 9k to 40 GHz 10k to 18GHz 100-240V/20kVA 100-240V/17kVA 10T █ █ █ Matsuda █ x2 █ x5 █ x5 9k to 40GHz 10k to 18GHz 100-240V/15kVA 100-240V/15kVA 5T 80 to Nagano █ █ x3 █ x3 9k to 40GHz 1000MHz 100-240V/6kVA 100-240V/6kVA 1T Tochigi █ x3 █ x3 9k to 40GHz 100-240V/6kVA 100-240V/6kVA 5T █ x2 48V 100-240V 100-240V Shenzhen 9k to 18GHz 150k to 3GHz 3A 1T 16A 16A Taiwan █ x2 9k to 40GHz 150k to 3GHz 12–48V 100–240V 110–230V 200kg 30A 25A 25A 2 shield rooms for conducted emissions, power disturbance, 0-240V single phase 0-120V Guangzhou magnetic emissions, and immunity tests 0-380V three phases single phase Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS) █ a. Full anechoic chamber used in Hong Kong for Immunity only
  • 3. European EMC Capabilities Semi-anechoic Emissions Test Frequency Range Electrical Power Chambers Sites (OATs) Location Load 10 30 10 30 3m 3m Emissions Immunity DC 50Hz 60Hz m m m m 0-300V Italy 150kHz to 240V-22A 240V-22A █a █ █ 9kHz to 18GHz 4.2GHz 16A, 320V-16A 320V-16A 1T 0-80V 30A 0-135V, 37A 20 Hz to 26.5 10 kHz to 3 Finland █ GHz GHz 0-120V, 13A 100 – 690V, 63A 4T 135 – 270V, 18A 0-440 V 9 kHz to 26.5 150 kHz to 4 0-150 V 0-440 V Germany █ x2 █ █ GHz GHz 50 A 130 A per phase 110A 2T per phase 20Hz to 10kHz to 0-54V 100-240V 100-240V Sweden █ █ █ █ 40GHz 18GHz 200A 63A 16A 6T 20Hz to 20Hz to 0-100V 0-415V 0-110V UK █ 5m █ █ 40GHz 18GHz 200A 150A per phase 16A 3T Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS) █ a. Italy: full anechoic chamber