Micrologix 1000                  Prolific Pune
System Overview                  Prolific Pune
Multiple Processor
Configuration
Configuration
MicroLogix 1000 Controller SelectionCatalog   I/O      Digital       Analo    Digital        Analog    Real Input Power   ...
MicroLogix 1000 Controller Selection1761-      16 10    24V dc        0         6 contact    0          5W @ 24V dc     5V...
MicroLogix 1000 Controller Selection1761-      25 12    24V dc             2         8 contact       1          18W @ 120V...
MicroLogix 1000 Controller SelectionTransformer       Memory       Timer/Co    Program         I/O         Communicatio   ...
Divce Net interfaceCatalog No./    Function                   Communicat Communication Rates          Current LoadProduct ...
MicroLogix 1000 Hand-Held Programmer
AdvantagesThe MicroLogix 1000 family provides small, economical programmable controllers. They areavailable in configurati...
Functional DesignFour I/O sizes (i.e., 10, 16, 25, and 32 I/O) cover many applications.• Various electrical configurations...
Mechanical Design• Compact size enables the MicroLogix 1000 Controller to fit into tight spaces.• The MicroLogix 1000 cont...
Sequential Logic Controller (SLC)   CPU                                                   I/O ModulesPower Supply         ...
SLC Feature  Simple and affordable processors with broad capabilities to address applications such as material handling H...
SpecificationsBattery -:                                  SLC 5/01, 5/02, 5/03, 5/04, 5/05, 1747-BAModule-:               ...
Selecting the Processor categoryMax I/O I/O Communications              Max User         General           Processor      ...
Selecting the Processor category 1This type of I/O in this type of controller system requires a separate I/O scanner inst...
SLC 500 catalog Numbers-Fixed Hardware styleI/O              Inputs                      outputs                    Line  ...
SLC 500 catalog Numbers-Fixed Hardware style    I/O                    Inputs                       outputs             Li...
SLC 500 catalog Numbers-Fixed Hardware styleWith addition of 2 Slot expansion chassis to the fixed-Hardware-style controll...
SLC 500 ProcessorsProcessor & maximum             No. of O/I      Local        Program Scan     I/O ScanCatalog No User Me...
SLC ProcessorsProcessor &   maximum User      No. of O/I      Local analog   Program Scan      I/O ScanCatalog No    Memor...
SLC ProcessorsProcessor & maximum User       No. of O/I       Local        Program     I/O ScanCatalog No Memory          ...
SLC ProcessorsProcessor &   maximum User      No. of O/I      Local analog   Program Scan      I/O ScanCatalog No    Memor...
SLC Processors1 Modules slave protocol is embedded in the RTU-5/03 processors available from an Encompasspartner. The mod...
SLC 500 ProcessorsProcessor &   maximu     Max. No. of    Communicati    Backup      Backplane CurrentCatalog No    m No. ...
SLC 500 Processors (continued) Processor &        maximum        Max. No. of O/I Communic Backup                          ...
Memory DevicesCatalog          For this Product      Function               Memory SizeNumber/Product1747-M1 EEPROM   SLC ...
Memory DevicesMax I/O   I/O Type              Memory Communication     Control Systems   Section• 12      •Fixed digital I...
Memory DevicesMax I/O    I/O Type                   Memory          Communication          Control     Section            ...
Memory DevicesMax I/O    I/O Type                Memory       Communication        Control       Section                  ...
Memory DevicesMax I/O    I/O Type                Memory              Communication       Control      Section             ...
Systems Overview
Ethernet Communication
ControlNet Communication
DeviceNet
Universal Remote I/O
DH+ Communication
DH-485 Communication
SCADA Remote Systems
30930100 allen-bradley
Upcoming SlideShare
Loading in …5
×

30930100 allen-bradley

1,119 views

Published on

Published in: Business
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
1,119
On SlideShare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
43
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

30930100 allen-bradley

  1. 1. Micrologix 1000 Prolific Pune
  2. 2. System Overview Prolific Pune
  3. 3. Multiple Processor
  4. 4. Configuration
  5. 5. Configuration
  6. 6. MicroLogix 1000 Controller SelectionCatalog I/O Digital Analo Digital Analog Real Input Power Apparent InputNumber Inputs g Outputs Outputs Power Inputs1761- 10 6 24V dc 0 4 contact 0 13W @ 120V ac 24VA @ 120V acL10BWA inputs sink/source outputs 14W @ 240V ac 32VA @ 240V ac1761- 10 6 24V dc 0 4 contact 0 5W @ 24V dc 5VA @ 24V dcL10BWB inputs sink/source outputs1761- 16 10 120V ac 0 6 contact 0 7W @ 120V ac 8W 15VA @ 120V acL16AWA inputs outputs @ 240V ac 21VA @ 240 ac1761- 32 20 120V ac 0 12 contact 0 9.1W @ 120V ac 19VA @ 120V acL32AWA inputs outputs 10.6W @ 240V ac 25VA @ 240V ac1761- 16 10 24V dc 0 6 contact 0 14W @ 120V ac 26VA @ 120V acL16BWA inputs sink/source outputs 15W @ 240V ac 33VA @ 240V ac1761- 32 20 24V dc 0 12 contact 0 15W @ 120V ac 29VA @ 120V acL32BWA inputs sink/source outputs 16W @ 240V ac 36VA @ 240V ac1761- 32 20 120V ac 0 10 triac 0 7W @ 120V ac 9W 16VA @ 120V acL32AAA inputs outputs, @ 240V ac 22VA @ 240V ac 120/240V ac 2 contact outputs
  7. 7. MicroLogix 1000 Controller Selection1761- 16 10 24V dc 0 6 contact 0 5W @ 24V dc 5VA @ 24V dcL16BWB inputs sink/source outputs1761- 32 20 24V dc 0 12 contact 0 7W @ 24V dc 7VA @ 24V dcL32BWB inputs sink/source outputs1761- 16 10 24V dc 0 4 source 0 5W @ 24V dcL16BBB inputs sink/source 24V dc 5VA @ 24V dc outputs 2 contact outputs1761- 32 20 24V dc 0 10 source 0 7W @ 24V dcL32BBB inputs sink/source 24V dc 7VA @ 24V dc outputs 2 contact outputs1761- 25 12 120V ac 2 8 contact 1 12W @ 120V ac 20VA @ 120V acL20AWA-5 inputs voltag outputs voltage/ 13W @ 240V ac 27VA @ 240V acA e current (_10V) (0-10V, 2 4-20mA) current (0-20m A)
  8. 8. MicroLogix 1000 Controller Selection1761- 25 12 24V dc 2 8 contact 1 18W @ 120V ac 30VA @ 120V acL20BWA-5 inputs sink/source voltage outputs voltage/ 19W @ 240V ac 38VA @ 240V acA (_10V) current 2 (0-10V, current 4-20mA) (0-20m A)1761- 25 20 24V dc 2 8 contact 1 7W @ 24V dc 10VA @ 24V dcL20BWB-5 inputs sink/source voltage outputs voltage/A (_10V) current 2 (0-10V, current 4-20mA) (0-20m A) Specifications Power supply loading 83 mA @ 24V dc (1.99W) Operating Temperature 0 to 50° C (32 to 122° F) Storage Temperature -20 to 60° C (-4 to 140° F) Humidity 5 to 95% (without condensation) Display Type 2 line x 16 character (LCD)
  9. 9. MicroLogix 1000 Controller SelectionTransformer Memory Timer/Co Program I/O Communicatio Catalog No.Load size unter Scan Time / scan n Port Maximum K words Time33VA @120Vac 1K 40 timers 2ms (typical) 021ms RS232-C (Can 1761-L10BWA35 VA @240V ac words 32 (typical) be Configured (approxi counters forNot applicable mately communication 1761-L10BWB Fixed18 VA @120 V ac 737 thru 1761-NET- 1761-L16AWA20 VA @240 V ac instructio A/C in a n words DH-48523VA @120V ac 437 data- network) 1761-L32AWA27VA @240V ac table38VA @120V ac words) 1761-L16BWA40VA @240V ac18VA @120V ac 1761-L32AAA23VA @240V acNot applicable 1761-L16BWBNot applicable 1761-L32BWBNot applicable 1761-L16BBBNot applicable 1761-L32BBB30VA @120V ac 1761-L20AWA-5A33VA @ 120V ac45 VA@ 120V ac 1761-L20BWA-5A48 VA @ 240V acNot applicable 1761-L20BWB-5A
  10. 10. Divce Net interfaceCatalog No./ Function Communicat Communication Rates Current LoadProduct ion interface Supported (bit/s)1761-NET- Lets You connect a Dual- DeviceNet RS-232-C DeviceNet:DIN DeviceNet Micrologix controller shielded selectable selectable 0 - 200mARS232 C for other controller twisted pair 125k 1200 (@ 11 - 25V)interface With an RS 232-C port) (DeviceNet 250k to the DeviceNet 2400 Network. This allows network) 500k 4800 the controller to function as a device net 9600 slave node to Provide 19200 16 word of Input Data & 16 word of Output 38400 Data that can be exchanged with the DeviceNet Scanner. This also allows peer to peer messaging between controllers Lets you connect a PC- compatible computer to the DeviceNet network for peer-to peer messaging, for programming, and for on-line monitoring.
  11. 11. MicroLogix 1000 Hand-Held Programmer
  12. 12. AdvantagesThe MicroLogix 1000 family provides small, economical programmable controllers. They areavailable in configurations of 10 digital I/O (6 inputs and 4 outputs), 16 digital I/O (10 inputs and6 outputs), 25 I/O (12digital inputs, 4 analog inputs, 8 digital outputs, and 1 analog output), or 32digital I/O (20 inputs and 12 outputs) in 5 electrical configurations of digital I/O. The I/O optionsand electrical configurations make them ideal for many applications.• Compact design of hardware lets the MicroLogix 1000 controller fit in limited panel space.• Choice of communication networks. An RS-232-C communication port is configurable for DF1protocol for direct connection to a programming device or operator interface; thru a 1761-NET-AIC converter in a DH-485 network; thru a 1761-NET-DNI interface in a Device Net network; orfor half-duplex slave protocol in SCADA applications.• Programming is simple. You can program the controllers in familiar ladder logic. This symbolicprogramming language is based on relay ladder wiring diagrams that simplify the creation andtroubleshooting of your control program.• A comprehensive instruction set of over 65 instructions includes simple bit, timer, and counterinstructions, as well as instructions for powerful applications such as sequencers, high-speedcounter, and shift registers.• Fast. Execution time for a typical 500-instruction program is only 1.56ms.• Choice of programming device. You can program the controllers in familiar ladder logic withMicroLogix 1000 A.I. Series• Software, PLC 500 A. I. Series Programming Software, RSLogix 500L Windows ProgrammingSoftware, or the MicroLogix Hand-Held Programmer (1761-HHP-B30) using an enhancedinstruction list.• Choice of languages. Software and documentation are available in 5 languages. The hand-heldprogrammer has 6 languages built in.
  13. 13. Functional DesignFour I/O sizes (i.e., 10, 16, 25, and 32 I/O) cover many applications.• Various electrical configurations of digital I/O offer you acontroller that meets your electrical requirements:- 24V dc inputs and relay outputs with a 120/240V acpower supply- 120V ac inputs and relay outputs with a 120/240V acpower supply- 24V dc inputs and relay outputs with a 24V dc powersupply- 24V dc inputs and 24V dc FET and relay outputs with a24V dc power supply- 120V ac inputs and triac and relay outputs with a120/240V ac power supply• Isolated relay contact outputs (at least two per controller).Allow outputs on the same unit to switch different controlvoltages.• The 25-I/O models include 4 analog inputs and an analogoutput in addition to the 12 digital inputs and the 8 digital(contact) outputs
  14. 14. Mechanical Design• Compact size enables the MicroLogix 1000 Controller to fit into tight spaces.• The MicroLogix 1000 controller contains the power supply, processor, and all its I/Ocircuits packaged in a single unit.Communication• RS-232 communication port configurable for direct connection to your programmingdevice.•RS-232 communication port configurable for DH-485 communication thru an AIC+(1761-NET-AIC) converter. Lets you communicate with SLC processors, other MicroLogixcontrollers, operator interfaces, or programming devices in a DH-485 network.• RS-232 communication port configurable for communication thru a DevicNet interface(1761-NET-DNI) to let the controller function as a slave node in a DeviceNet network.• RS-232 communication port configurable for DF1 half-duplex slave protocol forconnection to a modem in SCADA applications. Specifications Power supply loading 83 mA @ 24V dc (1.99W) Operating Temperature 0 to 50° C (32 to 122° F) Storage Temperature -20 to 60° C (-4 to 140° F) Humidity 5 to 95% (without condensation) Display Type 2 line x 16 character (LCD) Keypad 30 Rubber/carbon-based keys Weight 0.3 kg (0.6 lb)
  15. 15. Sequential Logic Controller (SLC) CPU I/O ModulesPower Supply Prolific Pune
  16. 16. SLC Feature  Simple and affordable processors with broad capabilities to address applications such as material handling HVAC control, assembly operations, small process control, and SCADA applications Advance instruction set based on PLC-5, mid-size processors Board line of digital and analog I/O modules, including intelligent I/O modules and I/O modules available from third-party (Encompass program) vendor Each SLC 500 or SLC 5/01 processor has a Dh-485 port for programming and processor-to -process or communication initiated from the other node. SLC 5/02, 03, 04 and 05 processors have communication ports (Ethernet, DH+, DH-485 or RS-232-C) that can initiate communication. And controlNet I/O (1771-,1746-,1793,1794-,1797-/O modules) with a 1747- SCNR15 scanner module and DeviceNet I/O (1791D-1793-and 1794-I/O module and 1792-I/O blocks) with a 1747-SDN scanner module) Add Universal Remote l/O[1746-,1771-,1793-,and1794-l/O modules and 1791-l/O blocks] with a 1747- SN scanner module Add BASIC programming capability and DH -485 and RS -232 communication ports with a 1747-BAS module Prolific Pune
  17. 17. SpecificationsBattery -: SLC 5/01, 5/02, 5/03, 5/04, 5/05, 1747-BAModule-: SLC 500 and 5/01 processor are not compatible with 1746-BLM, 1746-BTM, 1746-MPM, 1746-HS, 1746-HSCE, 1746-QV, 1747-SN, 1747-SDN and1747- SCNR15 modules SLC5/02 are not compatible with 1746-BLM and 1746-MPM modulesShock-: Operating 30g (Modular Hardware)Vibration-: Displacement : 0.015 inches peak to peak @5-75Hz Acceleration: 2.5g@57-2000HZ Duration:1hr per axis (x, Y, Z) (Fixed Hardware)Environmental Condition – Operational temp. -: 0 to 600c (32-1400 F) Strong Temp. -: 40-850 c (-40 to 185 0F) Relative Humidity -: 5-95% (Without Condensation)Programming devices- 1747-PT1 Hand-Held Terminal1 1747-PTA1, E Memory Park 1 IBMPC-AT compatible Component Prolific Pune1 works with SLC 500, 5/01 and 5/02 processors only
  18. 18. Selecting the Processor categoryMax I/O I/O Communications Max User General Processor Memory Communication port84 thru Processor-resident local I/O 1K instruction DH-485 (Can not SLC 500104 initial message960 Processor-resident local I/O 1K or 4K DH-485 (Can not SLC 5/01 instruction initial message4096 in + Processor-resident local I/O 4K instruction DH-485 SLC 5/024096 out IO at remote location14096 in + Processor-resident local I/O 8K or 16 K words DH-485 SLC 5/034096 out IO at remote location1 total RS-23224096 in + Processor-resident local I/O 16K, 32K or 64K DH+ SLC 5/044096 out IO at remote location1 words total RS-23224096 in + Processor-resident local I/O 16K, 32K or 64K Ethernet SLC 5/054096 out IO at remote location1 words total RS-2322 Prolific Pune
  19. 19. Selecting the Processor category 1This type of I/O in this type of controller system requires a separate I/O scanner installedin an I/O Module slot to provide a control Net, Device Net, or universal Remote I/O port 2Configurable for communication thru a 1761-Net-AIC in a DH-485 network or thru a1761-net-DNI in a Device Net network. Prolific Pune
  20. 20. SLC 500 catalog Numbers-Fixed Hardware styleI/O Inputs outputs Line CatalogConfiguration Power No 20 ac contact 120/240 ac 1747-L20A 20 ac Triac 120/240 ac 1747-L20B 24 dc slink (Source Load) Contact 120/240 ac 1747-L20C 24 dc slink (Source Load) Triac 120/240 ac 1747-L20D 24 dc slink (Source Load) 24 dc transistor sources 120/240 ac 1747-L20E 24 dc slink (Source Load) 24 dc transistor sources 24V dc 1747-L20F 24 dc slink (Source Load) 24 dc transistor sources 24V dc 1747-L20G 12 inputs and 24 dc slink (Sink Load) 24 dc transistor sources 120/240 ac 1747-L20L 8 output 24 dc slink (Sink Load) 24 dc transistor sources 120/240 ac 1747-L20N 240V ac Contact 120/240 ac 1747-L20R 240 V ac Triac 120/240 ac 1747-L20P 120V ac Contact 120/240 ac 1747-L30A Prolific Pune
  21. 21. SLC 500 catalog Numbers-Fixed Hardware style I/O Inputs outputs Line Catalog NoConfiguration Power 120V ac Triac 120/240 ac 1747-L30B 24V dc Sink (Source Load) Contact 120/240 ac 1747-L30C 24V dc slink (Source Load) Triac 120/240 ac 1747-L30D18 inputs and 12 24V dc slink (Sink Load) 24 dc Transistor sink 120/240 ac 1747-L30Loutputs 240V ac Triac 120/240 ac 1747-L30P 120Vac Contact 120/240 ac 1747-L40A 120Vac Triac 120/240 ac 1747-L40B 24 dc slink (Source Load) Contact 120/240 ac 1747-L40C 24 dc slink (Source Load) 24 dc transistor sources 120/240 ac 1747-L40E 24 inputs and 24 dc slink (Source Load) Contact 24V dc 1747-L40F 16 output 24V dc slink (Sink Load) 24 dc transistor sources 120/240 ac 1747-L40L 240V ac Triac 120/240 ac 1747-L40P 2-Slot Expansion Chassis 1746-A2 Prolific Pune
  22. 22. SLC 500 catalog Numbers-Fixed Hardware styleWith addition of 2 Slot expansion chassis to the fixed-Hardware-style controller, a maximum of 32Additional I/O of any type (ac/dc/contact) can be installed. However, the following modules areIncompatible with these controllers; 1746sc-INI41, 1746-HSCE, 1746-QV, 1747-SN, 1747-SDNAlso some combination of module are incompatible because to back plane current loading. Prolific Pune
  23. 23. SLC 500 ProcessorsProcessor & maximum No. of O/I Local Program Scan I/O ScanCatalog No User Memory analog I/O Time/K word Time Max SLC 5001747-L20 1 K instructions 84 4 8ms(typ) 2.6ms(typ) 1747-L30 1 K instructions 94 4 8ms(typ) 2.6ma(typ) 1747-L40 1 K instructions 104 4 8ms(typ) 2.6ma(typ) SLC 5/01 1K instructions 960 absolute 96 8ms(typ) 2.6ma(typ) 1747-L511 maximum (Local2 4K instructions 960 absolute 96 8ms(typ) 2.6ma(typ) 1747-L514 maximum (Local2 SLC 5/02 4K instructions 4096 in+ 4096 96 4.8ms(typ) 1.6ma(typ) 174-L524 out absolute maximum2 Prolific Pune
  24. 24. SLC ProcessorsProcessor & maximum User No. of O/I Local analog Program Scan I/O ScanCatalog No Memory I/O Max Time/K word Time SLC 5/03 11747-L531 8K words total 4096 in+ 4096 96 1ms(typ) 0.225ms(typ) (4 K word for out absolute Data & Program) maximum 2 4 K for Data Only 16K word total 4096 in+ 4096 96 1ms(typ) 0.225ma(typ) (12 K word for out absolute 1747-L532 Data & Program) maximum 2.3 4 K for Data Only SLC 5/04 16K word total 4096 in+ 4096 96 0.9ms(typ) 0.225ma(typ) (12 K word for out absolute 1747-L541 Data & Program) maximum 2.3 4 K for Data Only 32K word total 4096 in+ 4096 96 0.9ms(typ) 0.225ma(typ) (12 K word for out absolute 1747-L542 Data & Program) maximum2.3 4 K for Data Only Prolific Pune
  25. 25. SLC ProcessorsProcessor & maximum User No. of O/I Local Program I/O ScanCatalog No Memory analog I/O Scan Time/K Time Max word SLC 5/041747-L541 16 words total (12 4096 in+ 4096 96 0.9ms(typ) 0.225ms(typ) K words for Data out absolute & Program) maximum2.3 4 K for Data Only 32K word total 4096 in+ 4096 96 0.9ms(typ) 0.225ma(typ) (28 K word for out absolute 1747-L542 Data & Program) maximum2 4 K for Data Only 64K word total 4096 in+ 4096 96 0.9ms(typ) 0.225ma(typ) (50 K word for out absolute 1747-L543 Data & Program) maximum2 4 K for Data Only Prolific Pune
  26. 26. SLC ProcessorsProcessor & maximum User No. of O/I Local analog Program Scan I/O ScanCatalog No Memory I/O Max Time/K word Time SLC 5/051747-L551 16K word total 4096 in+ 4096 96 0.9ms(typ) 0.225ms(typ) (12 K words for out absolute Data & Program) maximum2.3 4 K for Data Only 32K word total 4096 in+ 4096 96 0.9ms(typ) 0.225ma(typ) (28 K word for out absolute 1747-L552 Data & Program) maximum 2.3 4 K for Data Only 64K word total 4096 in+ 4096 96 0.9ms(typ) 0.225ma(typ) (60 K word for out absolute 1747-L553 Data & Program) maximum 3 4 K for Data Only Prolific Pune
  27. 27. SLC Processors1 Modules slave protocol is embedded in the RTU-5/03 processors available from an Encompasspartner. The modbus slave protocol is supported on the RS-232 port (Channel10)2 The absolute maximum number of I/O for these processors only reflect the I/O addressing capability. If dosenot take in to account the amount of memory that may be required for a ladder logic program to monitor andcontrol the I/O.The practical ratio of memory per I/O is totally dependent upon your specific application3 you can not configure this no. of I/O for these processors with local I/O only. To configure this no. of I/O for these processors, you must add a 1747-SN Remote I/O scanner module to configure I/O on universal remote I/Olink, add 1747-SDN device Net scanner module to configure I/O on a Device Net scanner module to configure I/OModule to configure I/O on a control Net. Prolific Pune
  28. 28. SLC 500 ProcessorsProcessor & maximu Max. No. of Communicati Backup Backplane CurrentCatalog No m No. O/I model on Memory Load of local slots in the I/O Local I/O chassis chassis SLC 500 1747-L20 1K 2 DH-4853 EEPROM or Not applicable (Fixed style UVPROM 1K 2 DH-4853 EEPROM or Not applicable (Fixed 1747-L30 UVPROM style) 1K 2 DH-4853 EEPROM or Not applicable (Fixed style 1747-L40 UVPROM SLC 5/01 3K 30 DH-4853 EEPROM or 350mA@5Vdc 1747-L511 UVPROM 105mA@2Vdc 3K 30 DH-4853 EEPROM or 350mA@5Vdc 1747-L514 UVPROM 105mA@2Vdc SLC 5/02 32 30 DH-4853 EEPROM or 350mA@5Vdc 174-L524 UVPROM 105mA@2Vdc Prolific Pune
  29. 29. SLC 500 Processors (continued) Processor & maximum Max. No. of O/I Communic Backup Backplane Current Catalog No No. of model slots in ation Ports Memory Load local I/O the Local I/O chassis chassis SLC 5/05 1747-L551 32 30 Ethernet Flash 1.0A @ 5Vdc Rs-232 5 200mA @ 24V dc 32 30 Ethernet Flash 1.0A @ 5Vdc 1747-L552 Rs-232 5 200mA @ 24V dc 32 30 Ethernet Flash 1.0A @ 5Vdc 1747-L553 Rs-232 5 200mA @ 24V dc1. I/O chassis-a physical assembly that houses I/O2. With this processor, You an also install a 1747-SN Remote I/O Scanner Module to Configure I/O on a universal remote I/O link and/or add a 1747-SDN Device net scanner module to configure I/O on a Device Net network, You can configure 32 I/O chassis per Universal Remote I/O scanner using Complementary I/O, You an configure 16 I/O chassis per universal remote I/O scanner with the Device Net Scanner, You can address a maximum of 63 Device Net device Net Network.3. An SLC 500 or 5/01 processor can only receive message and send replay message to command message send from other nods on the Dh-485 network; it cannot initiate communication.4. The SLC 5/03 has an RS-232 port, which can also be configured for a DH-485 network, enabling the SLC –5/03 to connect to two DH-485,network simultaneously.5. The SLC 5/04 and SLC 5/05 have an RS-232 port, which can also be configured for a DH-485 network Prolific Pune
  30. 30. Memory DevicesCatalog For this Product Function Memory SizeNumber/Product1747-M1 EEPROM SLC 500 Processor Program & Data table 8K byte, 1k storage instructions1747-M2 EEPROM SLC 500 Processor Program & Data table 32K byte, 4k storage instructions1747-M3 UPROM SLC 500 Processor Program & Data table 8K byte, 1k storage instructions1747-M4 UPROM SLC 500 Processor Program & Data table 32K byte, 4k storage instructions1747-M11 Flash SL 5/03 and 5/04 Program & Data table 28K instructions (4K-Memory processors (at. No. storage word data table 1747-L541 or –L5421747-M11 Flash SLC 5/03 OS302 Program & Data table 60K instructions (4K-Memory Processor or higher storage word data table Or SL 5/04 OS401 processor or higher (Cat. No.1747-L543
  31. 31. Memory DevicesMax I/O I/O Type Memory Communication Control Systems Section• 12 •Fixed digital I/O •1 k 3•18 •Fixed Analog I/O PICO / 1760 Words•10 4•16 •1K •Devicenet4 MicroLogix •Fixed Digital I/O•25 Words •DH-485 4 1000/1761 •Fixed Analog I/O•32 •RS-232-C •Devicenet4 5 •Fixed Digital I/O •DH-485 4 • 6 Local I/O •6K •RS-232-C Micrologix•88 module words • Modbus RTU 12001762 slave •Devicenet4 6 •Fixed Digital I/O •DH-485 4•152 7.65 K Micrologix • 8 Local I/O •RS-232-C•156 Words 15001769 module • Modbus RTU slave
  32. 32. Memory DevicesMax I/O I/O Type Memory Communication Control Section Systems •Fixed Hardware• 84 •Ethernet 5 3•94 digital I/O Plus 2 local •Device net 4 I/O modules•104 • DH+ •30 local I/O modules•960 •1 k Words •DH-485 SLC/1746 •Control Net I/O•4096 •RS-232-C •Device Net I/O 3 •Universal Remote •Universal Remote I/O 3 I/O512 thru 43072 • Processor-resident •6K thru • Ethernet 5(any local I/O 100K •Device net 4Mix) 2 • Extended Local I/O Words • DH+ PLC-5/177 • Control Net I/O •Protected 1 •RS-232-C/422- •Device Net I/O 3 A/423-A •Universal Remote I/O •Universal Remote I/O •Ethernet/IP4 10 •Local I/O •Device net 4 Compact•128 •64 K bytes Logix / • DH-485 4 1769 •RS-232-C (DF-1)
  33. 33. Memory DevicesMax I/O I/O Type Memory Communication Control Section Systems• 256 •localI/O • 64 K •Ethernet FlexLogix/ 11 •Control Net I/O bytes •Control Net 1794 • Extended local I/O • 512 K •Device net bytes •RS-232-C •Extended local I/ O512 thru •localI/O •160K • Ethernet Control 123072 •Ether Net IP/I/O bytes •Device net Logix /(any •Control Net I/O • 672K • Control Net 1756Mix) 2 bytes •Device Net I/O 3 • DH+ •1 M bytes •Universal Remote I/O •RS-232-C (DF/1/ •2 M bytes DH –485) •Universal Remote I/O •Ethernet 13 •Device net•Not •ControlNet I/O •Not • Control Net Softlogix58applicab •Device Net I/O 3 applicable • DH+ 00le •Universal Remote I/O •Universal Remote I/O
  34. 34. Memory DevicesMax I/O I/O Type Memory Communication Control Section Systems896 thru •Extended local I/O •32k thru 100K • Ethernet Open 144096 •Device Net I/O 3 words plus 64 •Device net Automati(any •Universal Remote I/O bytes for VME • Control Net on andMix) 2 Memory Industrial • DH+ •4M-byte RAM Compute •RS-232-C •8M-byte RAM r RS-232-C/422-A/ •16M-byte RAM 423-A •32M-byte RAM •Universal •64M-byte RAM Remote I/O1. This includes Universal Remote I/O and Device Net I/O2. This does not include Device Net I/O3. This type of I/O in this type of Controller system requires a separate I/O scannerinstalled in a modules slot5. These are not on board ports. They are available only thru an interface6. Only some have on-board Ethernet ports. But all have the capability to have anEthernet Port added thru an interface
  35. 35. Systems Overview
  36. 36. Ethernet Communication
  37. 37. ControlNet Communication
  38. 38. DeviceNet
  39. 39. Universal Remote I/O
  40. 40. DH+ Communication
  41. 41. DH-485 Communication
  42. 42. SCADA Remote Systems

×