International Journal of Applied Power Engineering (IJAPE)
Vol. 3, No. 2, August 2014, pp. 105~114
ISSN: 2252-8792  105
Journal homepage: http://iaesjournal.com/online/index.php/IJAPE
Ash Cooler Heat Recovery Under Energy Conservation Scheme
Vikash R Gupta*, Lalatendu Pattanayak**
* Surat Lignite Power Plant, Nani Narolai, Mangrol, Surat, Gujrat, India
** Steag Energy Services India Pvt. Ltd, A-29, Sector-16, Noida, UP, India
Article Info ABSTRACT
Article history:
Received Mar 2, 2014
Revised Jul 10, 2014
Accepted Jul 23, 2014
A healthy fluidization state in circulating fluidized-bed combustion (CFBC)
combustor is attributed to proper quantity of hot bed material (ash), which
acts as a thermal fly-wheel. It receives & stores thermal energy from the
burning of fuel (lignite) & distributes uniformly throughout the combustor &
helps in maintaining a sustained combustion. The quantity of bed ash inside
the combustor or size of the bed, depends upon boiler load & subsequently
upon combustor temperature, lignite feed rate and ash % in lignite. As these
parameters varies during process continuously, sometimes it becomes
necessary to drain out the ash from the combustor. As & when differential
pressure across the bed is increased from a justified level, draining of hot bed
ash starts into Ash Coolers. Bed ash is drained at very high temperature of
850 o
C & it also contains burning particles of lignite. This paper describes
the heat recovery from bed ash, unloaded from the combustor into ash cooler,
by pre-heating the condensate water of turbine cycle in a 125 MW CFB
boiler of Surat Lignite Power Plant in India. The thermal performance of ash
cooler was derived by doing a heat balance calculation based on the
measured temperature of ash and cooling water with different load. From the
heat balance calculation influence of ash temperature and ash amount on heat
transfer coefficient is determined. Simulation is carried out around main
turbine cycle indicates improved thermal economy of the unit, higher plant
thermal efficiency, lower plant heat rate and reduce fuel consumption rate.
Also simulation result shows that the heat transfer coefficient increase with
ash amount and decreases with increase in ash temperature.
Keyword:
Ash cooler
Bed ash
Combustor
Heat transfer
Thermal economy
Copyright © 2014 Institute of Advanced Engineering and Science.
All rights reserved.
Corresponding Author:
Lalatendu Pattanayak,
Departement of System Technologies,
Steag Energy Services India Pvt. Ltd,
A-29, Sector-16, Noida, UP, 201301, India.
Email: l.pattanayak@steag.in
1. INTRODUCTION
Circulating fluidized bed (CFB) combustion have found acceptance throughout the world over the
past few years, in particular for power generation, but also as industrial power plants and combined heat and
power stations [1]. CFB boiler is one of the best clean coal fired boiler for its merits, such as allowing the
uses of broad range of fuels, meeting the environmental pollution norms without addition of add on
equipment and better efficiency. In a CFB boiler, coal is fed into the furnace with a wide particle size
distribution. After it is burned, ash is formed and ash particles become part of the bed material in the furnace
[2]. As a key auxiliary device ash coolers are the boiler auxiliary installed at zero meter of combustor. Ash
coolers are key auxiliary device connected at the bottom part of CFB combustor, which has a direct influence
on economic operation of the CFB boiler [3], [4]. It is widely used in boilers based on CFBC technology for
cooling of hot bed ash. Ash coolers are attributed to their high efficiency and excellent reliability. CFB boiler
bottom ash contains large amounts of physical heat. The physical heat loss is up to 2 % without cooling the
bottom ash while the boiler combusts a low calorie fuel with more than 30 % ash content. In addition the red
 ISSN: 2252-8792
IJAPE Vol. 3, No. 2, August 2014 : 105 – 114
106
hot bottom ash is not conducive to be mechanized for handling and transportation. Thus a bottom ash cooler
is often used to treat high temperature bottom ash to reclaim heat, and to have the ash easily transported [5],
[6].
A healthy fluidization state in CFBC combustor is attributed to proper quantity of hot bed material
(ash), which acts as a thermal fly-wheel which receives & stores thermal energy from the burning of fuel
(lignite) & distributes uniformly throughout the combustor & helps in maintaining a sustained combustion.
The size of bed inside combustor or quantity of bed ash depends upon boiler load & subsequently upon
combustor temperature, lignite feed rate and ash % in lignite. As these parameters varies during process
continuously, sometimes it becomes necessary to drain out the ash from the combustor. As & when
differential pressure across the bed is increased from a justified level, draining of hot bed ash starts into ash
coolers. Bed ash is drained at very high temperature of 850 o
C & it also contains burning particles of lignite.
For cooling, bed ash is kept in fluidized state around the cooling coils carrying de-mineralized (DM) water.
During cooling process of ash, a portion of heat gets recovered through the vent connected with the
combustor. Another portion of heat gets wasted through cooling water circuit. Finally the cold ash unloaded
in bed ash conveyor through rotary air lock feeders.
Wang et al. [7] developed a heat transfer model of the rotary ash cooler to predict the heat transfer
characteristics in a commercial 300 MW CFB boiler. The result revealed that the heat-transfer coefficients of
ash-air and air-water are close but much lower than that of ash-water, indicating that the heat transfer of ash-
water dominates in the total heat transfer. B.Zeng et al. [8] in their study determines the influence of CFB
boiler bottom ash heat recovery mode on thermal economy of unit based on heat balance calculation and
analysis of three typical CFB power plants with FBAC or RAC to recover the heat of boiler bottom ash. W.
Wang et al. [9] built a dynamic experimental system to measure the overall heat transfer coefficient in the
rolling ash cooler and the influencing factors, such as ash size, ash amount and rotational speed using the
orthogonal design. The result revels that the ash size has the greatest effect on heat transfer coefficient.
Zhang et al. [10] researched a water-cooled waste heat recovery system in a 410 t/h CFB boiler, and analyzed
the economic benefits gained by transferring the waste heat of high temperature bottom ash to the turbine
regenerative system. In this study, effects on the plant thermal economy resulted from the parallel installation
of BAC and different low-pressure heaters were also calculated by equivalent enthalpy drop method.
However, the differences in thermal economy of units caused by different heat recovery modes were not
included.
This paper describes the heat recovery from bed ash, unloaded from the combustor into ash cooler,
by pre-heating the condensate water of turbine cycle in a 125 MW CFB boiler of Surat Lignite Power Plant
in India. The thermal performance of ash cooler was derived by doing a heat balance calculation based on the
measured temperature of ash and cooling water with different load. From the heat balance calculation
influence of ash temperature and ash amount on heat transfer coefficient is determined. Simulation is carried
out around main turbine cycle indicates improved thermal economy of the unit, higher plant thermal
efficiency, lower plant heat rate and reduce fuel consumption rate. Also simulation result shows that the heat
transfer coefficient increase with ash amount and decreases with increase in ash temperature.
2. PRESENT SCENARIO
Figure 1 illustrates the principle heat and mass balance diagram of 125 MW CFB power plant
located in Surat, India. 125MW CFB combustor is a partially top and partially bottom supported boiler with
re-heater system. Fluidized bed heat exchangers as integral part consisting reheater (RH), superheater (SH)
and evaporator coils. It can deliver 390 t/h of main steam at 132 kg/cm2
pressure and 535+ 5 o
C temperature,
with resident time of 5 seconds.
There are three chambers in a ash cooler, with refractory lined walls. First chamber called ‘empty
chamber’ is connected with ash drain out of the combustor with fluidizing nozzles at the floor, other two
chambers are provided with cooling coils carrying auxiliary cooling water (ACW), normally DM water and
fluidizing air fed from the bottom through nozzles to keep hot ash in fluidizing state. This in turn results in
cooling of ash unloaded from the combustor from time to time. The hot air vented in to the combustor and
the cold ash finally unloaded in bed ash conveyor. Basic layout of CFB boiler is shown in Figure 2.
IJAPE ISSN: 2252-8792 
Ash Cooler Heat Recovery Under Energy Conservation Scheme (Lalatendu Pattanayak)
107
Figure 1. Heat and mass balance diagram based on manufacturer data.
Figure 2. Basic lay out of the boiler.
Bed ash is being cooled in ash coolers with the help of ACW (180 t/h per ash cooler) , which in turn
getting cooled by condenser cooling water (CCW) system and huge amount of heat is going waste through
cooling tower via CCW system. Existing schematic diagram of the low pressure side is shown in Figure 3.
General technical parameters and main design parameters of AC is shown in Table 1 and 2, respectively.
Figure 3. Existing scheme
3. PROPOSED SCHEME
Schematic diagram proposed for this study is shown in Figure 4. The scheme is to use condensate
water in place of ACW, and is proposed to be diverted to ash cooler from drain cooler outlet & after
circulation through ash coolers, fed it back at the inlet of low pressure heater (LPH 1). As & when
temperature of condensate will rise due to bed ash unloading in AC, the flow of steam extractions from low
pressure turbine (LPT) to LPH 1 & LPH 2, which was being used for condensate pre-heating, will be reduced
automatically and this extra steam will be diverted towards LPT exhaust and in turn will produce more
power.
 ISSN: 2252-8792
IJAPE Vol. 3, No. 2, August 2014 : 105 – 114
108
Table 1. General Technical Parameters of 125 MW Surat Lignite Thermal Power Plant
Properties Values
Steam turbine parameters (rated power/Main steam pressure
/Main steam temperature / temperature of reheat steam)
125 MW/126 at/535 o
C/535 o
C
LPT Exhaust steam parameters (Pressure/Specific
enthalpy)
0.097 at/ 579.525 kcal/kg
Feed water temperature 235 o
C
Boiler parameters
pressure of superheated steam/temperature
of superheated steam/temperature of
reheat steam)
126 at/540 o
C/540 o
C
The amount of bottom ash 40% of total ash
Make-up water rate 0 t/h
Boiler efficiency, 80.17%
TG heat rate 1990.57 kcal/kWh
TG heat Rate (PG test) 2030 kcal/kWh
TG heat Rate (Operating) 2060 kcal/kWh
Coal Ultimate Analysis Design Operating
Carbon 43.30 % 38.84 %
Hydrogen 3.14 % 2.42 %
Nitrogen 0.81 % 0.4 %
Sulphur 1.2 % 0.45 %
Oxygen 8.53 % 5.8 %
Moisture 24 % 45 %
Ash 15.02 % 5.7 %
Lime 4 % 2 %
HHV (Higher heating value) 3000 kcal/kg 3268 kcal/kg
Table 2. The main parameters of Ash Cooler
Properties Design Operating
Inlet temperature of cooling water (o
C) 36 36
Outlet temperature of cooling water (o
C) 76-80 76-80
Inlet temperature of bottom ash (o
C) 850 – 900 850-900
Outlet temperature of bottom ash (o
C) 120 120
Figure 4. Proposed scheme
Based on the proposed scheme heat and mass balance calculation is performed using Ebsilon®
Professional [11] collecting sample data from the plant distributed control system (DCS) during actual
operating condition of plant in full load of 125 MW. Figure 5 depicts the heat and mass balance diagram
based on the proposed scheme.
4. RESULTS AND DISCUSSION
The simulation carried out around main turbine cycle indicates improved thermal economy of the
unit, higher plant thermal efficiency, lower plant heat rate and reduce fuel consumption rate. Simulation
results show that the heat transfer coefficient increase with ash amount and decreases with increase in ash
temperature. Figure 6 depicts the simulation results of the improvement of turbine cycle heat rate with
extracting the heat from the bottom ash. It can be see that at 47.72 o
C there is no heating takes place, i.e when
there is no ash unloading, the turbine cycle heat rate is found to be 2060.83 kcal/kWh. When ash unloading
takes place the condensate temperature rises and heat rate of turbine cycle improves to 2054.04 kcal/kWh.
Which correspond to an increase in generation of 0.34 % as shown in Figure 6. As the condensate in the low
pressure circuit is being heated by the utilization of heat from the bottom ash there is a reduction in extraction
steam flow to the LPH 3 and LPH 2 is around 10.33% and 50%, respectively which ultimately increase the
power output and LPT performance. Simulation results before and after modification is depicted in Table 3
IJAPE ISSN: 2252-8792 
Ash Cooler Heat Recovery Under Energy Conservation Scheme (Lalatendu Pattanayak)
109
for low pressure circuit. For each case the heat rate and total power generation improves by extracting the
heat from unloading ash.
Figure 5. Proposed heat balance based on operating data
Figure 6. Gross turbine heat rate/ load vs condensate temperature
Main benefit of such arrangement is, the heat energy which was going waste which is in a huge amount
(average for a month is around 19.47 MWhr) is saved and it is equivalent to extra generation of 2.6 MUs or
saving of 2328 MT lignite over a period of 330 days in a year, assuming 40 % Turbine cycle efficiency.
Other benefits achieved by extracting the heat from the bed ash in the ash cooler are found out as,
 After diverting condensate flow through ash coolers, the loading of 360 t/h (rated cooling water flow
is 180 t/h per ash cooler) over the ACW pumping system will reduce, this will result into saving of
at least 42 kW at pump shaft power. This is equivalent to 3.33 lacs kWh in 330 days in a year.
 CCW flow requirement to cool 360 t/h of ACW will be reduced on CCW system & in turn, heat
loading on cooling tower will also be reduced.
2053.00
2054.00
2055.00
2056.00
2057.00
2058.00
2059.00
2060.00
2061.00
2062.00
124.95
125.00
125.05
125.10
125.15
125.20
125.25
125.30
125.35
125.40
125.45
45.00 55.00 65.00 75.00 85.00 95.00
TGheatrate(kcal/kWh)
Load(MW)
Condensate temperature (oC )
Rise in generator output and improvement in TG heat rate with rise in
condensate water temperature when ash is being unloaded
Gross generation TG heat rate
(47.72 oC corresponds to no heating /
no ash unloading)
 ISSN: 2252-8792
IJAPE Vol. 3, No. 2, August 2014 : 105 – 114
110
 Unnecessary running of ACW & CCW pumps, when there is no ash unloading in to ash coolers will
be saved.
 The extracted heat from the ash increases the loading of main cooling towers. This extra loading
will be avoided.
 When ash is unloaded, it increases the ACW temp abruptly for a short period, this enhances the risk
of tripping of other auxiliary which are sensitive to cooling water temp or running at just overload.
This risk may be avoided.
 If this modification works, further step will be to stop or remove CCW pumps along with we can
think of the relocation of plate heat exchanger (PHE) at zero meter.
Table 3. Simulation results before and after modification
Particulars Parameters Before and After Modification
Before After Modification - Full Load
Load (MW) 125.00 125.04 125.06 125.08 125.11 125.17 125.32 125.42
Turbine heat rate (kcal/kWh) 2060.83 2060.27 2059.89 2059.49 2059.08 2058.05 2055.65 2054.0
4
Main Steam Flow (t/h) 379.84 379.84 379.84 379.84 379.84 379.84 379.84 379.84
Condenser Back Pressure (mbar) 99.36 100.44 101.18 101.94 102.71 103.42 104.40 105.00
Steam Quality at LPT Exhaust 0.9502 0.9508 0.9511 0.9515 0.9519 0.9522 0.9526 0.9529
Steam Quality at LPH-1 Inlet 0.9709 0.9716 0.9720 0.9725 0.9729 0.9733 0.9738 0.9742
CW Inlet temp (°C) 31.30 31.30 31.30 31.30 31.30 31.30 31.30 31.30
CW Flow Taken at (t/h) 15800 15800 15800 15800 15800 15800 15800 15800
LPH-1 Condensate Inlet Temp (°C) 47.72 55.00 60.00 65.00 70.00 75.00 82.00 86.00
LPH-1 Condensate Outlet Temp(°C) 67.60 69.41 70.64 71.89 73.16 75.90 82.02 86.02
Extraction Stm Flow to LPH-1 (t/h) 10.67 7.54 5.36 3.19 1.02 0.00 0.00 0.00
LPH-1 Drip to DC Temp (°C) 73.64 74.49 74.96 75.36 75.68 75.90 76.19 76.38
LPH-1 Drip to DC Pressure (at) 0.37 0.39 0.39 0.40 0.40 0.41 0.41 0.42
Saturation Temp at Drip Line (°C) 73.64 74.49 74.96 75.36 75.68 75.90 76.19 76.38
LPH-2 Condensate Inlet Temp (°C) 67.60 69.41 70.64 71.89 73.16 75.90 82.02 86.02
LPH-2 Condensate Outlet Temp (°C) 93.62 94.10 94.42 94.74 95.06 95.68 96.97 97.77
Extraction Stm Flow to LPH-2 (t/h) 14.26 13.53 13.03 12.52 12.00 10.82 8.13 6.34
LPH-2 Drip to LPH-1 Temp (°C) 97.50 97.86 98.09 98.33 98.56 98.97 99.77 100.22
LPH-2 Drip to LPH-1 Pressure (at) 0.95 0.96 0.97 0.97 0.98 1.00 1.03 1.04
Saturation Temp at Drip Line (°C) 97.50 97.86 98.09 98.33 98.56 98.97 99.77 100.22
LPH-3 Condensate Inlet Temp (°C) 94.29 94.76 95.07 95.38 95.70 96.31 97.57 98.35
LPH-3 Condensate Outlet Temp (°C) 119.80 119.96 120.07 120.18 120.28 120.48 120.90 121.16
Extraction Stm Flow to LPH-3 (t/h) 14.42 14.25 14.14 14.02 13.91 13.69 13.22 12.93
LPH-3 Drip to LPH-2 Temp (°C) 126.65 126.74 126.81 126.87 126.93 127.05 127.28 127.42
LPH-3 Drip to LPH-2 Pressure (at) 2.49 2.50 2.50 2.51 2.51 2.52 2.54 2.55
Saturation temp at drip line (°C) 126.65 126.74 126.81 126.87 126.93 127.05 127.28 127.42
De-Aerator Pressure (at) 5.34 5.34 5.35 5.35 5.36 5.36 5.38 5.39
Steam Flow to deaerator (t/h) 17.50 17.45 17.41 17.37 17.34 17.27 17.12 17.03
Load sharing HPT / IPT / LPT (MW) 33.93/
47.1/
45.89
33.93/
47.09/
45.94
33.93/
47.08/
45.97
33.93/
47.07/
46
33.93/
47.07/
46.03
33.93/
47.05/
46.11
33.93/
47.02/
46.29
33.93/
47.01/
46.4
Total Shaft power at Generator terminal
(MW)
126.94 126.97 127.00 127.02 127.05 127.11 127.26 127.36
IJAPE ISSN: 2252-8792 
Ash Cooler Heat Recovery Under Energy Conservation Scheme (Lalatendu Pattanayak)
111
Total instantaneous heat extracted by the
condensate from the bed ash
Total average heat extracted by the condensate from
the bed ash
Figure 7. Heat available in ACW water at the outlet of ash cooler
Heat available in ACW water at AC 1 & 2 is shown in Fig. 7(a) & (b). Total heat extracted is
calculated by calculating area under the curve above a datum of 9300 kcal for ACW flow of 265 t/h and/or
datum of 6600 kcal for ACW flow of 180t/h respectively at 36 o
C ACW outlet temperatures. Probable risk
factors and its remedial action are depicted in Table 4.
5. CONCLUSION
In this paper, the influence of heat recovery from bed ash by the ash cooler in a 125 MW lignite
fired coal plant is analyzed and its impact on thermal economy such as heat rate, generation and fuel
consumption is evaluated based on heat and mass balance calculation.
 The data (instantaneous & average) on which this study is made are collected from the DCS
system of a running unit, for a period of 33 days which covers all type of variations / changes
occurred. In the data collected, we have found total 742 No. of occasions of ash unloading in to
the ash coolers at different interval as well as quantity. From the data, various observations can
be made like how much quantity of ash was unloaded in how much time; (here Combustor DP
& bottom temperatures gives correct clue of ash quantity); what was the rate at which ACW
outlet temp rise to max; in how much time it ceases down to normal etc.
 Maximum outlet temperature of ACW was observed at 85 o
C / 119 o
C in the Average /
instantaneous temperature trend. This temp reaches to peak in average 15 minutes period after
ash unloaded (it varies with the quantity of ash drained from the combustor & already available
ash in ash coolers if previously unloaded ash is not cooled & drained in to conveyor.
 Maximum idle period during which ash was not unloaded from the combustor was found 10 hrs
approximately.
 Total heat released into ACW water in AC-1&2, which found at average 797.53 kW per hour or
19.14 MWhr per day average.
 This is the actual amount of heat energy derived from the parameters obtained from DCS on
daily average basis. It is higher than the heat calculated theoretically (by considering 10% ash
content in 2500MT lignite, burnt in a day, bed ash at 40 % of total ash and ash gets cooled
from 850 o
C to 120 o
C, Sp. Heat of ash– 0.84kJ/kg) due to some amount of carbon getting
drained in burning state with ash.
 More ash content will result into more heat recovery.
 CEP discharge (condensate water) cannot be diverted before or after Gland Steam Cooler &
Drain Cooler as it will disturb / block the Gland steam flow which is detrimental to turbine shaft
& may leads to tripping of the Unit.
Observations from the heat balance study:
 ISSN: 2252-8792
IJAPE Vol. 3, No. 2, August 2014 : 105 – 114
112
 Generator output increased by 0.34 MW at constant MS Flow, even though vacuum has been
deteriorated by 4.0 mbar. If we could maintain the vacuum by switching off one CCW pump (this
will stop the bypass flow by 1000 t/h & vacuum will improve) when Condensate temp is nearing to
its maximum then additional gain in MW output at generator terminal may be achieved.
 The improvement in TG Heat-rate by 5.7 kcal/kWh corresponds to AC outlet temperature or LPH 1
inlet temperature is maximum at 86 o
C. This is corresponds to the bed ash unloading in one ash
cooler up to 20 mbar combustor dp.
 Generator output may be made constant by reducing main steam flow by 1.93t/h at peak temperature
of condensate through ash cooler. This will save the steam consumption & in turn the fuel input.
 As condensate temperature starts increasing, load shared by low pressure turbine starts increasing,
while it starts reducing in inter mediate pressure turbine. High pressure turbine output remains
constant throughout. But there is an overall gain in generated MW.
 There will be a loss of 3.5 kW in generated MW, if we consider one degree loss of temperature of
condensate, for idle hours when no ash is being unloaded.
 Extraction steam flow to LPH 1 becomes zero at 76 o
C & above temps of condensate; extraction
steam flow to LPH 2 never becomes zero while LPH 3 extraction steam flow remains unaffected.
 Final temperature gain in condensate water after LPH 3 remains unchanged.
 In any case of temperature rise in ash cooler, the pressure of water will always be well above
saturation pressure, so there is no chance of steaming inside the coils.
Table 4. Risk factors and solution
Sr.
No. Risk Factors Solution
1 LPT exhaust losses & inter-stage losses may be
increased with deteriorated vacuum.
There is very minor change in wetness fraction of the steam at extraction
points for LPH 1 & exhaust, however exact loss cannot be calculated.
2 Pulsating load may set up in LPT, which is not
permissible.
Loading variation in LPT will be as per ramp given by OEM (2.5 MW
/min). From the data analysis, whenever ash is unloaded, the peak
temperature reached in 15 minutes period or more, depending upon the
amount of ash. Any change taking place in LPT in 15 minute period
cannot be termed as a pulsating load)
3 Vibrations may set up in LPH tubes as condensate
temperature changes.
This condition may occur only when steaming (flash) takes place inside
tubes, but it is not possible in this case at all loads, actual condensate
pressure will always be is greater than saturation pressure.
4 Flash may occur in drip piping system / LPH
tubes / LPH shell.
1. In the LPHs circuit, this possibility of flashing has been nullified by
maintaining a height difference of @ 4.0 m (By installing DC at zero
m level), so there is no question of drip flashing at any point.
2. Inside the LPH-1 shell, flash in drip water may occur if temp of
condensate at inlet is higher than drip temp coming from LPH 2. This
case can be avoided if we unload the ash in controlled manner so that
condensate temp at LPH 1 inlet should not exceed from 78 deg C.
There is no threat to LPT as drip line is connected to condenser via
DC & LPFT, if any back pressure generates, it will go through the
drip pipe to condenser.
However maximum temperature rise may be addressed while designing
the new coils for ash coolers.
5 LPH 1 condensate inlet temp exceeding than
design.
Tube side design temperature is 150 o
C and max condensate temp will be
average out to 85o
C, when it will be mixed with Condensate outlet flow
from other ash cooler, which is not in service.
6 Recovery of heat may be achieved by using any
other idea / system – we should not disturb the
original thermal system – it may have detrimental
effect on the turbine life.
As ash unloading instances depend upon many other factors, there is no
fixed interval between two instances of ash unloading. Hence, heat from
the drained bed ash is non continuous nature. This inconsistent nature of
heat availability will not be suitable to any recovery system because
every system needs a regular, constant, reliable source of energy for
proper & efficient functioning. Earlier we had thought of using it in
VAM, but it was not suitable source. So only the turbine thermal cycle is
the best place to recover this waste heat.
7 Due to pressure & temperature drop in the
condensate circuit (After DC via Ash Cooler to
LPH 1) loss of heat when no ash is being
unloaded in the circuit may offset the saving.
There is a minor loss of enthalpy. It depends upon piping layout, no of
bends, no of valves & valve type etc. It has been estimated at 880 kcal/hr
- by assuming 1.2 at pressure & 1 o
C temperature drop in condensate
water, which will be lost during the period when no ash is unloaded.
This amount of heat is so negligible when compared with 5 to 6.5 lac
kcal hourly average heat. Suppose for the whole day, ash is not
unloaded, there will be 21200.0 kcal will be lost and this is equal to 8.0
IJAPE ISSN: 2252-8792 
Ash Cooler Heat Recovery Under Energy Conservation Scheme (Lalatendu Pattanayak)
113
units of electricity only, which can be recovered in a single smallest
instance of ash unloading; however max idle period was found at 10 hrs
from the collected data when ash was not unloaded.
8 When condensate will admitted into ash cooler,
max temperature rise will be 123 o
C (average 109
o
C), this will limit the use of both ash coolers at a
time. Also there are the chances of ‘flash’ in the
system.
The temperature mentioned is well below the saturation temperature at
that pressure, so there is no chance of ‘flashing’. This situation will arise
when heavy amount of ash is being unloaded, certainly it will limit the
use of both ash coolers at a time. However such type of incidence is
rare. Moreover, if ash is drained in both ash coolers simultaneously,
combustor DP cannot be controlled.
9 There will be extended period of cooling cycle of
hot ash in ash cooler after each incidence of ash
unloading due to increased temp of cooling water(
condensate, if modified).
However it is a minor variation, but can be sort out while designing the
new tube nest of ash cooler. The cold ash temperature will be 15 o
C
higher than ACW. The loss due to which is negligible.
10 The ash cooler in which ash is being unloaded
may need more water in case of heavy amount of
ash to avoid any thermal stroke.
Through the ash cooler, which is not in service, condensate flow can be
throttled to divert additional flow. To achieve this, additional valves
(Motorized valves) may be provided so that thermal shock can be
avoided.
11 At present ash cooler’s coil design capacity to
withstand pressure up to 10 kg/cm2
.
Condensate line pressure before de-aerator level control station is @ 16
kg/cm2
. So cooling coils capacity will have to be enhanced at 1.5 times
than at present.
12 We will have to keep ACW system always
available for situations like BTL & low load
conditions or unforeseen situation for a while.
For some period of observation, ACW system may be kept as standby
available. Later it may be abandoned.
13 Unforeseen situation creation in ash cooler like
when speiss valve has become fully open &
inoperative, leakage of coils etc.
Ash will accommodate in ash cooler up to its normal capacity only, after
that the ash inflow will be stopped and temp will start reducing. The max
rise in temp of ACW at outlet is found at 123 o
C, and mix temp of ACW
from both ACs max at 85 o
C. However to minimize thermal shock, max
condensate may be diverted through the ash cooler which is in problem.
14 What would happen when turbine is at low load? When Unit is running at low load, ash unloading from combustor also
reduced in quantity & occasions and condensate flow from CEP also
reduced. In this case maximum flow may be diverted to one ash cooler.
15 Heat from the ash is of intermittent nature. Heat from the ash is of intermittent nature as ash unloading instances
depend upon many other factors. This inconsistent nature of heat
availability is not useful for utilizing it in any other system like VAM;
because every system needs a regular, constant, reliable source of energy
for functioning, so thermal cycle is the best place to recover this waste
heat.
REFERENCES
[1] P. Gauville, J. Foucher and D. Moreau, "Achievable combustion efficiency with Alstom CFB boilers for burning
discarded coal," The Journal of The Southern African Institute of Mining and Metallurgy, vol. 112, pp. 437-447,
June 2012.
[2] G. Yue, J. Lu and H. Zhang, "Design theory of circulating fluidized bed boilers,in: Jia(Ed.)," in Proceeding of the
18th International Conference on Fluidized Bed Combustion, Toronto, 2005.
[3] J. Lv and G. Yue, "The CFB Boilers Operation and Overhaul," Beijing, 2003.
[4] E. Carrea, G. Scavizzi and J. Barsin, "Dry Bottom Ash Removal-Ash Cooling vs Boiler Efficiency Effects," in
International Joint Power Generation Conference, 1998.
[5] K. Cen, M. Ni, Z. Luo, Z. Yan, Y. Chi and M. Fang, Theory design and operation of circulating fluidized bed boiler,
Beijing: China Electric power Press, 1997.
[6] X. Lu, Large-scale circulating fluidized bed boiler equipment and operation, Beijing: China Electric Power Press,
2006.
[7] W. Wang, X. Si, H. Yang, H. Zhang and J. Lu, "Heat-Transfer Model of the Rotary Ash Cooler Used in Circulating
Fluidized-Bed Boilers," in Energy Fuels, 2010.
[8] B. Zeng, X. Lu and H. Liu, "Influence of CFB (circulating fluidized bed) boiler bottom ash heat recovery mode on
thermal economy of units," Energy, vol. 35, pp. 3863-3869, 2010.
[9] W. Wang, J. J. Li, S. Yang, X. Si, H. R. Yang, J. F. Lu and G. X. Yue, "EXPERIMENTAL STUDY ON HEAT
TRANSFER IN A ROLLING ASH COOLER USED IN THE CFB BOILER," in Proceedings ofthe 20th International
Conference on Fluidized Bed Combustion.
[10] N. Zhang, F. Sun, X. Ding and X. Huang, "An analysis and Optimization of waste heat Utilization Involving water-
cooled ash-slag Discharged from CFB boilers," Journal of Engineering for Thermal Energy and Power, vol. 21(3),
pp. 311-316, 2006.
 ISSN: 2252-8792
IJAPE Vol. 3, No. 2, August 2014 : 105 – 114
114
[11] "http://www.steag-systemtechnologies.com/ebsilon_professional+M52087573ab0.html," [Online].
BIOGRAPHIES OF AUTHORS
Vikar R Gupta: Working as Manager (TS) at SLPP, having work experience of more than 22
years in operation and mentanance of thermal power plants. Holds a degree in Electrical
engineering. Interest area of research in energy efficiency of energy systems.
Lalatendu Pattanayak: Working as DGM (System Technology dept.) at Steag Energy Services
India Pvt. Ltd. Holds a M.Tech degree in Environmental Science and Engineering and Post
graduate diploma in Thermal Power Plant Engineering. Interest area of research thermodynamic
modeling, power plant optimization and energy efficiency in thermal power plants. Is a member
in ASME since February 2014.

More Related Content

What's hot

Bioenergy-Insight
Bioenergy-InsightBioenergy-Insight
Bioenergy-InsightSamit Pethe
 
Waste heat recovery system on board ships
Waste heat recovery system on board shipsWaste heat recovery system on board ships
Waste heat recovery system on board shipsfahrenheit
 
Co2 emission rate per MWh of energy generated from coal fired plants
Co2 emission rate per MWh of energy generated from coal fired plantsCo2 emission rate per MWh of energy generated from coal fired plants
Co2 emission rate per MWh of energy generated from coal fired plantsDavid Palmer, EIT
 
To Improve Thermal Efficiency of 27mw Coal Fired Power Plant
To Improve Thermal Efficiency of 27mw Coal Fired Power PlantTo Improve Thermal Efficiency of 27mw Coal Fired Power Plant
To Improve Thermal Efficiency of 27mw Coal Fired Power PlantIJMER
 
Improving steam boiler operating efficiency
Improving steam boiler operating efficiencyImproving steam boiler operating efficiency
Improving steam boiler operating efficiencyNaqqash Sajid
 
2013 ASME Power Conference Analysis of Turbine Cycle Performance, Operation a...
2013 ASME Power Conference Analysis of Turbine Cycle Performance, Operation a...2013 ASME Power Conference Analysis of Turbine Cycle Performance, Operation a...
2013 ASME Power Conference Analysis of Turbine Cycle Performance, Operation a...Komandur Sunder Raj, P.E.
 
Burners and combustion system for the reheat furnaces for small and medium ro...
Burners and combustion system for the reheat furnaces for small and medium ro...Burners and combustion system for the reheat furnaces for small and medium ro...
Burners and combustion system for the reheat furnaces for small and medium ro...Shirish Karve
 
005 energy saving tips
005 energy saving tips005 energy saving tips
005 energy saving tipsAnil Palamwar
 
Air Source Heat Pumps - Thomas Dickson - Glow Worm
Air Source Heat Pumps - Thomas Dickson - Glow WormAir Source Heat Pumps - Thomas Dickson - Glow Worm
Air Source Heat Pumps - Thomas Dickson - Glow WormEuro Energy Services
 
Escape 24 biomass power plant with integrated drying-effective utilization of...
Escape 24 biomass power plant with integrated drying-effective utilization of...Escape 24 biomass power plant with integrated drying-effective utilization of...
Escape 24 biomass power plant with integrated drying-effective utilization of...Tesfaldet Gebregerges
 
IJSRED-V2I5P17
IJSRED-V2I5P17IJSRED-V2I5P17
IJSRED-V2I5P17IJSRED
 
Boilers Classifications and Cost per kWh
Boilers Classifications and Cost per kWh Boilers Classifications and Cost per kWh
Boilers Classifications and Cost per kWh salehkhan
 
waste heat recovery
waste heat recovery waste heat recovery
waste heat recovery Sagar Joshi
 
Thermal Efficiency of Buildings - Stefan Huber - Paul Heat Recovery Scotland
Thermal Efficiency of Buildings - Stefan Huber - Paul Heat Recovery ScotlandThermal Efficiency of Buildings - Stefan Huber - Paul Heat Recovery Scotland
Thermal Efficiency of Buildings - Stefan Huber - Paul Heat Recovery ScotlandEuro Energy Services
 
50 watt sterling engine
50 watt sterling engine50 watt sterling engine
50 watt sterling engineTufel Noorani
 
Power plant engineering unit 2 notes by Varun Pratap Singh
Power plant engineering unit 2 notes by Varun Pratap SinghPower plant engineering unit 2 notes by Varun Pratap Singh
Power plant engineering unit 2 notes by Varun Pratap SinghVarun Pratap Singh
 

What's hot (20)

Bioenergy-Insight
Bioenergy-InsightBioenergy-Insight
Bioenergy-Insight
 
Article - 2013 PTQ Q4
Article - 2013 PTQ Q4Article - 2013 PTQ Q4
Article - 2013 PTQ Q4
 
Waste heat recovery system on board ships
Waste heat recovery system on board shipsWaste heat recovery system on board ships
Waste heat recovery system on board ships
 
Co2 emission rate per MWh of energy generated from coal fired plants
Co2 emission rate per MWh of energy generated from coal fired plantsCo2 emission rate per MWh of energy generated from coal fired plants
Co2 emission rate per MWh of energy generated from coal fired plants
 
To Improve Thermal Efficiency of 27mw Coal Fired Power Plant
To Improve Thermal Efficiency of 27mw Coal Fired Power PlantTo Improve Thermal Efficiency of 27mw Coal Fired Power Plant
To Improve Thermal Efficiency of 27mw Coal Fired Power Plant
 
Improving steam boiler operating efficiency
Improving steam boiler operating efficiencyImproving steam boiler operating efficiency
Improving steam boiler operating efficiency
 
2013 ASME Power Conference Analysis of Turbine Cycle Performance, Operation a...
2013 ASME Power Conference Analysis of Turbine Cycle Performance, Operation a...2013 ASME Power Conference Analysis of Turbine Cycle Performance, Operation a...
2013 ASME Power Conference Analysis of Turbine Cycle Performance, Operation a...
 
Burners and combustion system for the reheat furnaces for small and medium ro...
Burners and combustion system for the reheat furnaces for small and medium ro...Burners and combustion system for the reheat furnaces for small and medium ro...
Burners and combustion system for the reheat furnaces for small and medium ro...
 
005 energy saving tips
005 energy saving tips005 energy saving tips
005 energy saving tips
 
Air Source Heat Pumps - Thomas Dickson - Glow Worm
Air Source Heat Pumps - Thomas Dickson - Glow WormAir Source Heat Pumps - Thomas Dickson - Glow Worm
Air Source Heat Pumps - Thomas Dickson - Glow Worm
 
Conserve energy
Conserve energyConserve energy
Conserve energy
 
Beer combustion
Beer combustionBeer combustion
Beer combustion
 
Escape 24 biomass power plant with integrated drying-effective utilization of...
Escape 24 biomass power plant with integrated drying-effective utilization of...Escape 24 biomass power plant with integrated drying-effective utilization of...
Escape 24 biomass power plant with integrated drying-effective utilization of...
 
IJSRED-V2I5P17
IJSRED-V2I5P17IJSRED-V2I5P17
IJSRED-V2I5P17
 
Boilers Classifications and Cost per kWh
Boilers Classifications and Cost per kWh Boilers Classifications and Cost per kWh
Boilers Classifications and Cost per kWh
 
waste heat recovery
waste heat recovery waste heat recovery
waste heat recovery
 
Thermal Efficiency of Buildings - Stefan Huber - Paul Heat Recovery Scotland
Thermal Efficiency of Buildings - Stefan Huber - Paul Heat Recovery ScotlandThermal Efficiency of Buildings - Stefan Huber - Paul Heat Recovery Scotland
Thermal Efficiency of Buildings - Stefan Huber - Paul Heat Recovery Scotland
 
371 379
371 379371 379
371 379
 
50 watt sterling engine
50 watt sterling engine50 watt sterling engine
50 watt sterling engine
 
Power plant engineering unit 2 notes by Varun Pratap Singh
Power plant engineering unit 2 notes by Varun Pratap SinghPower plant engineering unit 2 notes by Varun Pratap Singh
Power plant engineering unit 2 notes by Varun Pratap Singh
 

Similar to Ash Cooler Heat Recovery Under Energy Conservation Scheme

WASTE HEAT RECOVERY TO INCREASE BOILER EFFICIENCY USING BAGASSE AS FUEL
WASTE HEAT RECOVERY TO INCREASE BOILER EFFICIENCY USING BAGASSE AS FUEL WASTE HEAT RECOVERY TO INCREASE BOILER EFFICIENCY USING BAGASSE AS FUEL
WASTE HEAT RECOVERY TO INCREASE BOILER EFFICIENCY USING BAGASSE AS FUEL IAEME Publication
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlHossam Zein
 
Design and Development of Small Scale VAR System by Using Exhaust Gas of IC E...
Design and Development of Small Scale VAR System by Using Exhaust Gas of IC E...Design and Development of Small Scale VAR System by Using Exhaust Gas of IC E...
Design and Development of Small Scale VAR System by Using Exhaust Gas of IC E...IRJET Journal
 
Thermal Analysis and Optimization of a regenerator in a Solar Stirling engine
Thermal Analysis and Optimization of a regenerator in a Solar Stirling engineThermal Analysis and Optimization of a regenerator in a Solar Stirling engine
Thermal Analysis and Optimization of a regenerator in a Solar Stirling engineRohith Jayaram
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)IJERD Editor
 
78201906
7820190678201906
78201906IJRAT
 
78201906
7820190678201906
78201906IJRAT
 
Presentation on Kota super Thermal Power Station
Presentation on Kota super Thermal Power StationPresentation on Kota super Thermal Power Station
Presentation on Kota super Thermal Power Stationpukhraj palariya
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plantRabi Kumar
 
Flue gas low temperature heat recovery system for air conditioning
Flue gas low temperature heat recovery system for air conditioningFlue gas low temperature heat recovery system for air conditioning
Flue gas low temperature heat recovery system for air conditioningeSAT Journals
 
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...IRJET Journal
 
performance analysis of steam power plants using ideal reheat rankin cycle
performance analysis of steam power plants using ideal reheat rankin cycleperformance analysis of steam power plants using ideal reheat rankin cycle
performance analysis of steam power plants using ideal reheat rankin cycleIJAEMSJORNAL
 
Thermal Efficiency of Combined Cycle Power Plant
Thermal Efficiency of Combined Cycle Power PlantThermal Efficiency of Combined Cycle Power Plant
Thermal Efficiency of Combined Cycle Power PlantDr. Amarjeet Singh
 
iaetsd Thermal energy audit of kiln system in a cement plant
iaetsd Thermal energy audit of kiln system in a cement plantiaetsd Thermal energy audit of kiln system in a cement plant
iaetsd Thermal energy audit of kiln system in a cement plantIaetsd Iaetsd
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)IJERD Editor
 
EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF POROUS RADIANT BURNER AN...
EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF POROUS RADIANT BURNER AN...EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF POROUS RADIANT BURNER AN...
EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF POROUS RADIANT BURNER AN...BIBHUTI BHUSAN SAMANTARAY
 

Similar to Ash Cooler Heat Recovery Under Energy Conservation Scheme (20)

WASTE HEAT RECOVERY TO INCREASE BOILER EFFICIENCY USING BAGASSE AS FUEL
WASTE HEAT RECOVERY TO INCREASE BOILER EFFICIENCY USING BAGASSE AS FUEL WASTE HEAT RECOVERY TO INCREASE BOILER EFFICIENCY USING BAGASSE AS FUEL
WASTE HEAT RECOVERY TO INCREASE BOILER EFFICIENCY USING BAGASSE AS FUEL
 
30120140502013
3012014050201330120140502013
30120140502013
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater control
 
Design and Development of Small Scale VAR System by Using Exhaust Gas of IC E...
Design and Development of Small Scale VAR System by Using Exhaust Gas of IC E...Design and Development of Small Scale VAR System by Using Exhaust Gas of IC E...
Design and Development of Small Scale VAR System by Using Exhaust Gas of IC E...
 
Thermal Analysis and Optimization of a regenerator in a Solar Stirling engine
Thermal Analysis and Optimization of a regenerator in a Solar Stirling engineThermal Analysis and Optimization of a regenerator in a Solar Stirling engine
Thermal Analysis and Optimization of a regenerator in a Solar Stirling engine
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)
 
78201906
7820190678201906
78201906
 
78201906
7820190678201906
78201906
 
Chap 01 STEAM
Chap 01 STEAMChap 01 STEAM
Chap 01 STEAM
 
Chap 01
Chap 01Chap 01
Chap 01
 
Presentation on Kota super Thermal Power Station
Presentation on Kota super Thermal Power StationPresentation on Kota super Thermal Power Station
Presentation on Kota super Thermal Power Station
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plant
 
Flue gas low temperature heat recovery system for air conditioning
Flue gas low temperature heat recovery system for air conditioningFlue gas low temperature heat recovery system for air conditioning
Flue gas low temperature heat recovery system for air conditioning
 
6
66
6
 
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
IRJET- A Review on Developing a Model that Uses Waste Heat from Condenser in ...
 
performance analysis of steam power plants using ideal reheat rankin cycle
performance analysis of steam power plants using ideal reheat rankin cycleperformance analysis of steam power plants using ideal reheat rankin cycle
performance analysis of steam power plants using ideal reheat rankin cycle
 
Thermal Efficiency of Combined Cycle Power Plant
Thermal Efficiency of Combined Cycle Power PlantThermal Efficiency of Combined Cycle Power Plant
Thermal Efficiency of Combined Cycle Power Plant
 
iaetsd Thermal energy audit of kiln system in a cement plant
iaetsd Thermal energy audit of kiln system in a cement plantiaetsd Thermal energy audit of kiln system in a cement plant
iaetsd Thermal energy audit of kiln system in a cement plant
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)
 
EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF POROUS RADIANT BURNER AN...
EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF POROUS RADIANT BURNER AN...EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF POROUS RADIANT BURNER AN...
EXPERIMENTAL INVESTIGATION ON THERMAL PERFORMANCE OF POROUS RADIANT BURNER AN...
 

More from IJAPEJOURNAL

Effects of the Droop Speed Governor and Automatic Generation Control AGC on G...
Effects of the Droop Speed Governor and Automatic Generation Control AGC on G...Effects of the Droop Speed Governor and Automatic Generation Control AGC on G...
Effects of the Droop Speed Governor and Automatic Generation Control AGC on G...IJAPEJOURNAL
 
Underwater Target Tracking Using Unscented Kalman Filter
Underwater Target Tracking Using Unscented Kalman FilterUnderwater Target Tracking Using Unscented Kalman Filter
Underwater Target Tracking Using Unscented Kalman FilterIJAPEJOURNAL
 
Investigation of Dependent Rikitake System to Initiation Point
Investigation of Dependent Rikitake System to Initiation PointInvestigation of Dependent Rikitake System to Initiation Point
Investigation of Dependent Rikitake System to Initiation PointIJAPEJOURNAL
 
Optimization of Economic Load Dispatch with Unit Commitment on Multi Machine
Optimization of Economic Load Dispatch with Unit Commitment on Multi MachineOptimization of Economic Load Dispatch with Unit Commitment on Multi Machine
Optimization of Economic Load Dispatch with Unit Commitment on Multi MachineIJAPEJOURNAL
 
Impact of Buried Conductor Length on Computation of Earth Grid Resistance
Impact of Buried Conductor Length on Computation of Earth Grid ResistanceImpact of Buried Conductor Length on Computation of Earth Grid Resistance
Impact of Buried Conductor Length on Computation of Earth Grid ResistanceIJAPEJOURNAL
 
Enhancing Photoelectric Conversion Efficiency of Solar Panel by Water Cooling
Enhancing Photoelectric Conversion Efficiency of Solar Panel by Water CoolingEnhancing Photoelectric Conversion Efficiency of Solar Panel by Water Cooling
Enhancing Photoelectric Conversion Efficiency of Solar Panel by Water CoolingIJAPEJOURNAL
 
PMU-Based Transmission Line Parameter Identification at China Southern Power ...
PMU-Based Transmission Line Parameter Identification at China Southern Power ...PMU-Based Transmission Line Parameter Identification at China Southern Power ...
PMU-Based Transmission Line Parameter Identification at China Southern Power ...IJAPEJOURNAL
 
Investigation of Electric Field Distribution Inside 500/220 kV Transformation...
Investigation of Electric Field Distribution Inside 500/220 kV Transformation...Investigation of Electric Field Distribution Inside 500/220 kV Transformation...
Investigation of Electric Field Distribution Inside 500/220 kV Transformation...IJAPEJOURNAL
 
Economic Load Dispatch for Multi-Generator Systems with Units Having Nonlinea...
Economic Load Dispatch for Multi-Generator Systems with Units Having Nonlinea...Economic Load Dispatch for Multi-Generator Systems with Units Having Nonlinea...
Economic Load Dispatch for Multi-Generator Systems with Units Having Nonlinea...IJAPEJOURNAL
 
Improving Light-Load Efficiency by Eliminating Interaction Effect in the Grid...
Improving Light-Load Efficiency by Eliminating Interaction Effect in the Grid...Improving Light-Load Efficiency by Eliminating Interaction Effect in the Grid...
Improving Light-Load Efficiency by Eliminating Interaction Effect in the Grid...IJAPEJOURNAL
 
An Application of Ulam-Hyers Stability in DC Motors
An Application of Ulam-Hyers Stability in DC MotorsAn Application of Ulam-Hyers Stability in DC Motors
An Application of Ulam-Hyers Stability in DC MotorsIJAPEJOURNAL
 
Implementation of Hybrid Generation Power System in Pakistan
Implementation of Hybrid Generation Power System in PakistanImplementation of Hybrid Generation Power System in Pakistan
Implementation of Hybrid Generation Power System in PakistanIJAPEJOURNAL
 
Modeling and Simulation of SVPWM Based Application
Modeling and Simulation of SVPWM Based ApplicationModeling and Simulation of SVPWM Based Application
Modeling and Simulation of SVPWM Based ApplicationIJAPEJOURNAL
 
Comparison of FACTS Devices for Two Area Power System Stability Enhancement u...
Comparison of FACTS Devices for Two Area Power System Stability Enhancement u...Comparison of FACTS Devices for Two Area Power System Stability Enhancement u...
Comparison of FACTS Devices for Two Area Power System Stability Enhancement u...IJAPEJOURNAL
 
Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid V...
Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid V...Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid V...
Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid V...IJAPEJOURNAL
 
Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution...
Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution...Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution...
Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution...IJAPEJOURNAL
 
Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Unde...
Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Unde...Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Unde...
Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Unde...IJAPEJOURNAL
 
Hybrid Generation Power System for Domestic Applications
Hybrid Generation Power System for Domestic ApplicationsHybrid Generation Power System for Domestic Applications
Hybrid Generation Power System for Domestic ApplicationsIJAPEJOURNAL
 
Harmonic Voltage Distortions in Power Systems Due to Non Linear Loads
Harmonic Voltage Distortions in Power Systems Due to Non Linear LoadsHarmonic Voltage Distortions in Power Systems Due to Non Linear Loads
Harmonic Voltage Distortions in Power Systems Due to Non Linear LoadsIJAPEJOURNAL
 
A Survey on Quality Changes in Positive, Negative and Combined Switching Stra...
A Survey on Quality Changes in Positive, Negative and Combined Switching Stra...A Survey on Quality Changes in Positive, Negative and Combined Switching Stra...
A Survey on Quality Changes in Positive, Negative and Combined Switching Stra...IJAPEJOURNAL
 

More from IJAPEJOURNAL (20)

Effects of the Droop Speed Governor and Automatic Generation Control AGC on G...
Effects of the Droop Speed Governor and Automatic Generation Control AGC on G...Effects of the Droop Speed Governor and Automatic Generation Control AGC on G...
Effects of the Droop Speed Governor and Automatic Generation Control AGC on G...
 
Underwater Target Tracking Using Unscented Kalman Filter
Underwater Target Tracking Using Unscented Kalman FilterUnderwater Target Tracking Using Unscented Kalman Filter
Underwater Target Tracking Using Unscented Kalman Filter
 
Investigation of Dependent Rikitake System to Initiation Point
Investigation of Dependent Rikitake System to Initiation PointInvestigation of Dependent Rikitake System to Initiation Point
Investigation of Dependent Rikitake System to Initiation Point
 
Optimization of Economic Load Dispatch with Unit Commitment on Multi Machine
Optimization of Economic Load Dispatch with Unit Commitment on Multi MachineOptimization of Economic Load Dispatch with Unit Commitment on Multi Machine
Optimization of Economic Load Dispatch with Unit Commitment on Multi Machine
 
Impact of Buried Conductor Length on Computation of Earth Grid Resistance
Impact of Buried Conductor Length on Computation of Earth Grid ResistanceImpact of Buried Conductor Length on Computation of Earth Grid Resistance
Impact of Buried Conductor Length on Computation of Earth Grid Resistance
 
Enhancing Photoelectric Conversion Efficiency of Solar Panel by Water Cooling
Enhancing Photoelectric Conversion Efficiency of Solar Panel by Water CoolingEnhancing Photoelectric Conversion Efficiency of Solar Panel by Water Cooling
Enhancing Photoelectric Conversion Efficiency of Solar Panel by Water Cooling
 
PMU-Based Transmission Line Parameter Identification at China Southern Power ...
PMU-Based Transmission Line Parameter Identification at China Southern Power ...PMU-Based Transmission Line Parameter Identification at China Southern Power ...
PMU-Based Transmission Line Parameter Identification at China Southern Power ...
 
Investigation of Electric Field Distribution Inside 500/220 kV Transformation...
Investigation of Electric Field Distribution Inside 500/220 kV Transformation...Investigation of Electric Field Distribution Inside 500/220 kV Transformation...
Investigation of Electric Field Distribution Inside 500/220 kV Transformation...
 
Economic Load Dispatch for Multi-Generator Systems with Units Having Nonlinea...
Economic Load Dispatch for Multi-Generator Systems with Units Having Nonlinea...Economic Load Dispatch for Multi-Generator Systems with Units Having Nonlinea...
Economic Load Dispatch for Multi-Generator Systems with Units Having Nonlinea...
 
Improving Light-Load Efficiency by Eliminating Interaction Effect in the Grid...
Improving Light-Load Efficiency by Eliminating Interaction Effect in the Grid...Improving Light-Load Efficiency by Eliminating Interaction Effect in the Grid...
Improving Light-Load Efficiency by Eliminating Interaction Effect in the Grid...
 
An Application of Ulam-Hyers Stability in DC Motors
An Application of Ulam-Hyers Stability in DC MotorsAn Application of Ulam-Hyers Stability in DC Motors
An Application of Ulam-Hyers Stability in DC Motors
 
Implementation of Hybrid Generation Power System in Pakistan
Implementation of Hybrid Generation Power System in PakistanImplementation of Hybrid Generation Power System in Pakistan
Implementation of Hybrid Generation Power System in Pakistan
 
Modeling and Simulation of SVPWM Based Application
Modeling and Simulation of SVPWM Based ApplicationModeling and Simulation of SVPWM Based Application
Modeling and Simulation of SVPWM Based Application
 
Comparison of FACTS Devices for Two Area Power System Stability Enhancement u...
Comparison of FACTS Devices for Two Area Power System Stability Enhancement u...Comparison of FACTS Devices for Two Area Power System Stability Enhancement u...
Comparison of FACTS Devices for Two Area Power System Stability Enhancement u...
 
Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid V...
Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid V...Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid V...
Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid V...
 
Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution...
Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution...Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution...
Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution...
 
Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Unde...
Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Unde...Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Unde...
Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Unde...
 
Hybrid Generation Power System for Domestic Applications
Hybrid Generation Power System for Domestic ApplicationsHybrid Generation Power System for Domestic Applications
Hybrid Generation Power System for Domestic Applications
 
Harmonic Voltage Distortions in Power Systems Due to Non Linear Loads
Harmonic Voltage Distortions in Power Systems Due to Non Linear LoadsHarmonic Voltage Distortions in Power Systems Due to Non Linear Loads
Harmonic Voltage Distortions in Power Systems Due to Non Linear Loads
 
A Survey on Quality Changes in Positive, Negative and Combined Switching Stra...
A Survey on Quality Changes in Positive, Negative and Combined Switching Stra...A Survey on Quality Changes in Positive, Negative and Combined Switching Stra...
A Survey on Quality Changes in Positive, Negative and Combined Switching Stra...
 

Recently uploaded

Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort servicejennyeacort
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...Chandu841456
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxPoojaBan
 
pipeline in computer architecture design
pipeline in computer architecture  designpipeline in computer architecture  design
pipeline in computer architecture designssuser87fa0c1
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024Mark Billinghurst
 
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)Dr SOUNDIRARAJ N
 
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEINFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEroselinkalist12
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)dollysharma2066
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxbritheesh05
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
Effects of rheological properties on mixing
Effects of rheological properties on mixingEffects of rheological properties on mixing
Effects of rheological properties on mixingviprabot1
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineeringmalavadedarshan25
 
Introduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxIntroduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxk795866
 

Recently uploaded (20)

Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
 
young call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Serviceyoung call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Service
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
 
pipeline in computer architecture design
pipeline in computer architecture  designpipeline in computer architecture  design
pipeline in computer architecture design
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
 
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
 
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEINFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptx
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
Effects of rheological properties on mixing
Effects of rheological properties on mixingEffects of rheological properties on mixing
Effects of rheological properties on mixing
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineering
 
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
 
Introduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxIntroduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptx
 

Ash Cooler Heat Recovery Under Energy Conservation Scheme

  • 1. International Journal of Applied Power Engineering (IJAPE) Vol. 3, No. 2, August 2014, pp. 105~114 ISSN: 2252-8792  105 Journal homepage: http://iaesjournal.com/online/index.php/IJAPE Ash Cooler Heat Recovery Under Energy Conservation Scheme Vikash R Gupta*, Lalatendu Pattanayak** * Surat Lignite Power Plant, Nani Narolai, Mangrol, Surat, Gujrat, India ** Steag Energy Services India Pvt. Ltd, A-29, Sector-16, Noida, UP, India Article Info ABSTRACT Article history: Received Mar 2, 2014 Revised Jul 10, 2014 Accepted Jul 23, 2014 A healthy fluidization state in circulating fluidized-bed combustion (CFBC) combustor is attributed to proper quantity of hot bed material (ash), which acts as a thermal fly-wheel. It receives & stores thermal energy from the burning of fuel (lignite) & distributes uniformly throughout the combustor & helps in maintaining a sustained combustion. The quantity of bed ash inside the combustor or size of the bed, depends upon boiler load & subsequently upon combustor temperature, lignite feed rate and ash % in lignite. As these parameters varies during process continuously, sometimes it becomes necessary to drain out the ash from the combustor. As & when differential pressure across the bed is increased from a justified level, draining of hot bed ash starts into Ash Coolers. Bed ash is drained at very high temperature of 850 o C & it also contains burning particles of lignite. This paper describes the heat recovery from bed ash, unloaded from the combustor into ash cooler, by pre-heating the condensate water of turbine cycle in a 125 MW CFB boiler of Surat Lignite Power Plant in India. The thermal performance of ash cooler was derived by doing a heat balance calculation based on the measured temperature of ash and cooling water with different load. From the heat balance calculation influence of ash temperature and ash amount on heat transfer coefficient is determined. Simulation is carried out around main turbine cycle indicates improved thermal economy of the unit, higher plant thermal efficiency, lower plant heat rate and reduce fuel consumption rate. Also simulation result shows that the heat transfer coefficient increase with ash amount and decreases with increase in ash temperature. Keyword: Ash cooler Bed ash Combustor Heat transfer Thermal economy Copyright © 2014 Institute of Advanced Engineering and Science. All rights reserved. Corresponding Author: Lalatendu Pattanayak, Departement of System Technologies, Steag Energy Services India Pvt. Ltd, A-29, Sector-16, Noida, UP, 201301, India. Email: l.pattanayak@steag.in 1. INTRODUCTION Circulating fluidized bed (CFB) combustion have found acceptance throughout the world over the past few years, in particular for power generation, but also as industrial power plants and combined heat and power stations [1]. CFB boiler is one of the best clean coal fired boiler for its merits, such as allowing the uses of broad range of fuels, meeting the environmental pollution norms without addition of add on equipment and better efficiency. In a CFB boiler, coal is fed into the furnace with a wide particle size distribution. After it is burned, ash is formed and ash particles become part of the bed material in the furnace [2]. As a key auxiliary device ash coolers are the boiler auxiliary installed at zero meter of combustor. Ash coolers are key auxiliary device connected at the bottom part of CFB combustor, which has a direct influence on economic operation of the CFB boiler [3], [4]. It is widely used in boilers based on CFBC technology for cooling of hot bed ash. Ash coolers are attributed to their high efficiency and excellent reliability. CFB boiler bottom ash contains large amounts of physical heat. The physical heat loss is up to 2 % without cooling the bottom ash while the boiler combusts a low calorie fuel with more than 30 % ash content. In addition the red
  • 2.  ISSN: 2252-8792 IJAPE Vol. 3, No. 2, August 2014 : 105 – 114 106 hot bottom ash is not conducive to be mechanized for handling and transportation. Thus a bottom ash cooler is often used to treat high temperature bottom ash to reclaim heat, and to have the ash easily transported [5], [6]. A healthy fluidization state in CFBC combustor is attributed to proper quantity of hot bed material (ash), which acts as a thermal fly-wheel which receives & stores thermal energy from the burning of fuel (lignite) & distributes uniformly throughout the combustor & helps in maintaining a sustained combustion. The size of bed inside combustor or quantity of bed ash depends upon boiler load & subsequently upon combustor temperature, lignite feed rate and ash % in lignite. As these parameters varies during process continuously, sometimes it becomes necessary to drain out the ash from the combustor. As & when differential pressure across the bed is increased from a justified level, draining of hot bed ash starts into ash coolers. Bed ash is drained at very high temperature of 850 o C & it also contains burning particles of lignite. For cooling, bed ash is kept in fluidized state around the cooling coils carrying de-mineralized (DM) water. During cooling process of ash, a portion of heat gets recovered through the vent connected with the combustor. Another portion of heat gets wasted through cooling water circuit. Finally the cold ash unloaded in bed ash conveyor through rotary air lock feeders. Wang et al. [7] developed a heat transfer model of the rotary ash cooler to predict the heat transfer characteristics in a commercial 300 MW CFB boiler. The result revealed that the heat-transfer coefficients of ash-air and air-water are close but much lower than that of ash-water, indicating that the heat transfer of ash- water dominates in the total heat transfer. B.Zeng et al. [8] in their study determines the influence of CFB boiler bottom ash heat recovery mode on thermal economy of unit based on heat balance calculation and analysis of three typical CFB power plants with FBAC or RAC to recover the heat of boiler bottom ash. W. Wang et al. [9] built a dynamic experimental system to measure the overall heat transfer coefficient in the rolling ash cooler and the influencing factors, such as ash size, ash amount and rotational speed using the orthogonal design. The result revels that the ash size has the greatest effect on heat transfer coefficient. Zhang et al. [10] researched a water-cooled waste heat recovery system in a 410 t/h CFB boiler, and analyzed the economic benefits gained by transferring the waste heat of high temperature bottom ash to the turbine regenerative system. In this study, effects on the plant thermal economy resulted from the parallel installation of BAC and different low-pressure heaters were also calculated by equivalent enthalpy drop method. However, the differences in thermal economy of units caused by different heat recovery modes were not included. This paper describes the heat recovery from bed ash, unloaded from the combustor into ash cooler, by pre-heating the condensate water of turbine cycle in a 125 MW CFB boiler of Surat Lignite Power Plant in India. The thermal performance of ash cooler was derived by doing a heat balance calculation based on the measured temperature of ash and cooling water with different load. From the heat balance calculation influence of ash temperature and ash amount on heat transfer coefficient is determined. Simulation is carried out around main turbine cycle indicates improved thermal economy of the unit, higher plant thermal efficiency, lower plant heat rate and reduce fuel consumption rate. Also simulation result shows that the heat transfer coefficient increase with ash amount and decreases with increase in ash temperature. 2. PRESENT SCENARIO Figure 1 illustrates the principle heat and mass balance diagram of 125 MW CFB power plant located in Surat, India. 125MW CFB combustor is a partially top and partially bottom supported boiler with re-heater system. Fluidized bed heat exchangers as integral part consisting reheater (RH), superheater (SH) and evaporator coils. It can deliver 390 t/h of main steam at 132 kg/cm2 pressure and 535+ 5 o C temperature, with resident time of 5 seconds. There are three chambers in a ash cooler, with refractory lined walls. First chamber called ‘empty chamber’ is connected with ash drain out of the combustor with fluidizing nozzles at the floor, other two chambers are provided with cooling coils carrying auxiliary cooling water (ACW), normally DM water and fluidizing air fed from the bottom through nozzles to keep hot ash in fluidizing state. This in turn results in cooling of ash unloaded from the combustor from time to time. The hot air vented in to the combustor and the cold ash finally unloaded in bed ash conveyor. Basic layout of CFB boiler is shown in Figure 2.
  • 3. IJAPE ISSN: 2252-8792  Ash Cooler Heat Recovery Under Energy Conservation Scheme (Lalatendu Pattanayak) 107 Figure 1. Heat and mass balance diagram based on manufacturer data. Figure 2. Basic lay out of the boiler. Bed ash is being cooled in ash coolers with the help of ACW (180 t/h per ash cooler) , which in turn getting cooled by condenser cooling water (CCW) system and huge amount of heat is going waste through cooling tower via CCW system. Existing schematic diagram of the low pressure side is shown in Figure 3. General technical parameters and main design parameters of AC is shown in Table 1 and 2, respectively. Figure 3. Existing scheme 3. PROPOSED SCHEME Schematic diagram proposed for this study is shown in Figure 4. The scheme is to use condensate water in place of ACW, and is proposed to be diverted to ash cooler from drain cooler outlet & after circulation through ash coolers, fed it back at the inlet of low pressure heater (LPH 1). As & when temperature of condensate will rise due to bed ash unloading in AC, the flow of steam extractions from low pressure turbine (LPT) to LPH 1 & LPH 2, which was being used for condensate pre-heating, will be reduced automatically and this extra steam will be diverted towards LPT exhaust and in turn will produce more power.
  • 4.  ISSN: 2252-8792 IJAPE Vol. 3, No. 2, August 2014 : 105 – 114 108 Table 1. General Technical Parameters of 125 MW Surat Lignite Thermal Power Plant Properties Values Steam turbine parameters (rated power/Main steam pressure /Main steam temperature / temperature of reheat steam) 125 MW/126 at/535 o C/535 o C LPT Exhaust steam parameters (Pressure/Specific enthalpy) 0.097 at/ 579.525 kcal/kg Feed water temperature 235 o C Boiler parameters pressure of superheated steam/temperature of superheated steam/temperature of reheat steam) 126 at/540 o C/540 o C The amount of bottom ash 40% of total ash Make-up water rate 0 t/h Boiler efficiency, 80.17% TG heat rate 1990.57 kcal/kWh TG heat Rate (PG test) 2030 kcal/kWh TG heat Rate (Operating) 2060 kcal/kWh Coal Ultimate Analysis Design Operating Carbon 43.30 % 38.84 % Hydrogen 3.14 % 2.42 % Nitrogen 0.81 % 0.4 % Sulphur 1.2 % 0.45 % Oxygen 8.53 % 5.8 % Moisture 24 % 45 % Ash 15.02 % 5.7 % Lime 4 % 2 % HHV (Higher heating value) 3000 kcal/kg 3268 kcal/kg Table 2. The main parameters of Ash Cooler Properties Design Operating Inlet temperature of cooling water (o C) 36 36 Outlet temperature of cooling water (o C) 76-80 76-80 Inlet temperature of bottom ash (o C) 850 – 900 850-900 Outlet temperature of bottom ash (o C) 120 120 Figure 4. Proposed scheme Based on the proposed scheme heat and mass balance calculation is performed using Ebsilon® Professional [11] collecting sample data from the plant distributed control system (DCS) during actual operating condition of plant in full load of 125 MW. Figure 5 depicts the heat and mass balance diagram based on the proposed scheme. 4. RESULTS AND DISCUSSION The simulation carried out around main turbine cycle indicates improved thermal economy of the unit, higher plant thermal efficiency, lower plant heat rate and reduce fuel consumption rate. Simulation results show that the heat transfer coefficient increase with ash amount and decreases with increase in ash temperature. Figure 6 depicts the simulation results of the improvement of turbine cycle heat rate with extracting the heat from the bottom ash. It can be see that at 47.72 o C there is no heating takes place, i.e when there is no ash unloading, the turbine cycle heat rate is found to be 2060.83 kcal/kWh. When ash unloading takes place the condensate temperature rises and heat rate of turbine cycle improves to 2054.04 kcal/kWh. Which correspond to an increase in generation of 0.34 % as shown in Figure 6. As the condensate in the low pressure circuit is being heated by the utilization of heat from the bottom ash there is a reduction in extraction steam flow to the LPH 3 and LPH 2 is around 10.33% and 50%, respectively which ultimately increase the power output and LPT performance. Simulation results before and after modification is depicted in Table 3
  • 5. IJAPE ISSN: 2252-8792  Ash Cooler Heat Recovery Under Energy Conservation Scheme (Lalatendu Pattanayak) 109 for low pressure circuit. For each case the heat rate and total power generation improves by extracting the heat from unloading ash. Figure 5. Proposed heat balance based on operating data Figure 6. Gross turbine heat rate/ load vs condensate temperature Main benefit of such arrangement is, the heat energy which was going waste which is in a huge amount (average for a month is around 19.47 MWhr) is saved and it is equivalent to extra generation of 2.6 MUs or saving of 2328 MT lignite over a period of 330 days in a year, assuming 40 % Turbine cycle efficiency. Other benefits achieved by extracting the heat from the bed ash in the ash cooler are found out as,  After diverting condensate flow through ash coolers, the loading of 360 t/h (rated cooling water flow is 180 t/h per ash cooler) over the ACW pumping system will reduce, this will result into saving of at least 42 kW at pump shaft power. This is equivalent to 3.33 lacs kWh in 330 days in a year.  CCW flow requirement to cool 360 t/h of ACW will be reduced on CCW system & in turn, heat loading on cooling tower will also be reduced. 2053.00 2054.00 2055.00 2056.00 2057.00 2058.00 2059.00 2060.00 2061.00 2062.00 124.95 125.00 125.05 125.10 125.15 125.20 125.25 125.30 125.35 125.40 125.45 45.00 55.00 65.00 75.00 85.00 95.00 TGheatrate(kcal/kWh) Load(MW) Condensate temperature (oC ) Rise in generator output and improvement in TG heat rate with rise in condensate water temperature when ash is being unloaded Gross generation TG heat rate (47.72 oC corresponds to no heating / no ash unloading)
  • 6.  ISSN: 2252-8792 IJAPE Vol. 3, No. 2, August 2014 : 105 – 114 110  Unnecessary running of ACW & CCW pumps, when there is no ash unloading in to ash coolers will be saved.  The extracted heat from the ash increases the loading of main cooling towers. This extra loading will be avoided.  When ash is unloaded, it increases the ACW temp abruptly for a short period, this enhances the risk of tripping of other auxiliary which are sensitive to cooling water temp or running at just overload. This risk may be avoided.  If this modification works, further step will be to stop or remove CCW pumps along with we can think of the relocation of plate heat exchanger (PHE) at zero meter. Table 3. Simulation results before and after modification Particulars Parameters Before and After Modification Before After Modification - Full Load Load (MW) 125.00 125.04 125.06 125.08 125.11 125.17 125.32 125.42 Turbine heat rate (kcal/kWh) 2060.83 2060.27 2059.89 2059.49 2059.08 2058.05 2055.65 2054.0 4 Main Steam Flow (t/h) 379.84 379.84 379.84 379.84 379.84 379.84 379.84 379.84 Condenser Back Pressure (mbar) 99.36 100.44 101.18 101.94 102.71 103.42 104.40 105.00 Steam Quality at LPT Exhaust 0.9502 0.9508 0.9511 0.9515 0.9519 0.9522 0.9526 0.9529 Steam Quality at LPH-1 Inlet 0.9709 0.9716 0.9720 0.9725 0.9729 0.9733 0.9738 0.9742 CW Inlet temp (°C) 31.30 31.30 31.30 31.30 31.30 31.30 31.30 31.30 CW Flow Taken at (t/h) 15800 15800 15800 15800 15800 15800 15800 15800 LPH-1 Condensate Inlet Temp (°C) 47.72 55.00 60.00 65.00 70.00 75.00 82.00 86.00 LPH-1 Condensate Outlet Temp(°C) 67.60 69.41 70.64 71.89 73.16 75.90 82.02 86.02 Extraction Stm Flow to LPH-1 (t/h) 10.67 7.54 5.36 3.19 1.02 0.00 0.00 0.00 LPH-1 Drip to DC Temp (°C) 73.64 74.49 74.96 75.36 75.68 75.90 76.19 76.38 LPH-1 Drip to DC Pressure (at) 0.37 0.39 0.39 0.40 0.40 0.41 0.41 0.42 Saturation Temp at Drip Line (°C) 73.64 74.49 74.96 75.36 75.68 75.90 76.19 76.38 LPH-2 Condensate Inlet Temp (°C) 67.60 69.41 70.64 71.89 73.16 75.90 82.02 86.02 LPH-2 Condensate Outlet Temp (°C) 93.62 94.10 94.42 94.74 95.06 95.68 96.97 97.77 Extraction Stm Flow to LPH-2 (t/h) 14.26 13.53 13.03 12.52 12.00 10.82 8.13 6.34 LPH-2 Drip to LPH-1 Temp (°C) 97.50 97.86 98.09 98.33 98.56 98.97 99.77 100.22 LPH-2 Drip to LPH-1 Pressure (at) 0.95 0.96 0.97 0.97 0.98 1.00 1.03 1.04 Saturation Temp at Drip Line (°C) 97.50 97.86 98.09 98.33 98.56 98.97 99.77 100.22 LPH-3 Condensate Inlet Temp (°C) 94.29 94.76 95.07 95.38 95.70 96.31 97.57 98.35 LPH-3 Condensate Outlet Temp (°C) 119.80 119.96 120.07 120.18 120.28 120.48 120.90 121.16 Extraction Stm Flow to LPH-3 (t/h) 14.42 14.25 14.14 14.02 13.91 13.69 13.22 12.93 LPH-3 Drip to LPH-2 Temp (°C) 126.65 126.74 126.81 126.87 126.93 127.05 127.28 127.42 LPH-3 Drip to LPH-2 Pressure (at) 2.49 2.50 2.50 2.51 2.51 2.52 2.54 2.55 Saturation temp at drip line (°C) 126.65 126.74 126.81 126.87 126.93 127.05 127.28 127.42 De-Aerator Pressure (at) 5.34 5.34 5.35 5.35 5.36 5.36 5.38 5.39 Steam Flow to deaerator (t/h) 17.50 17.45 17.41 17.37 17.34 17.27 17.12 17.03 Load sharing HPT / IPT / LPT (MW) 33.93/ 47.1/ 45.89 33.93/ 47.09/ 45.94 33.93/ 47.08/ 45.97 33.93/ 47.07/ 46 33.93/ 47.07/ 46.03 33.93/ 47.05/ 46.11 33.93/ 47.02/ 46.29 33.93/ 47.01/ 46.4 Total Shaft power at Generator terminal (MW) 126.94 126.97 127.00 127.02 127.05 127.11 127.26 127.36
  • 7. IJAPE ISSN: 2252-8792  Ash Cooler Heat Recovery Under Energy Conservation Scheme (Lalatendu Pattanayak) 111 Total instantaneous heat extracted by the condensate from the bed ash Total average heat extracted by the condensate from the bed ash Figure 7. Heat available in ACW water at the outlet of ash cooler Heat available in ACW water at AC 1 & 2 is shown in Fig. 7(a) & (b). Total heat extracted is calculated by calculating area under the curve above a datum of 9300 kcal for ACW flow of 265 t/h and/or datum of 6600 kcal for ACW flow of 180t/h respectively at 36 o C ACW outlet temperatures. Probable risk factors and its remedial action are depicted in Table 4. 5. CONCLUSION In this paper, the influence of heat recovery from bed ash by the ash cooler in a 125 MW lignite fired coal plant is analyzed and its impact on thermal economy such as heat rate, generation and fuel consumption is evaluated based on heat and mass balance calculation.  The data (instantaneous & average) on which this study is made are collected from the DCS system of a running unit, for a period of 33 days which covers all type of variations / changes occurred. In the data collected, we have found total 742 No. of occasions of ash unloading in to the ash coolers at different interval as well as quantity. From the data, various observations can be made like how much quantity of ash was unloaded in how much time; (here Combustor DP & bottom temperatures gives correct clue of ash quantity); what was the rate at which ACW outlet temp rise to max; in how much time it ceases down to normal etc.  Maximum outlet temperature of ACW was observed at 85 o C / 119 o C in the Average / instantaneous temperature trend. This temp reaches to peak in average 15 minutes period after ash unloaded (it varies with the quantity of ash drained from the combustor & already available ash in ash coolers if previously unloaded ash is not cooled & drained in to conveyor.  Maximum idle period during which ash was not unloaded from the combustor was found 10 hrs approximately.  Total heat released into ACW water in AC-1&2, which found at average 797.53 kW per hour or 19.14 MWhr per day average.  This is the actual amount of heat energy derived from the parameters obtained from DCS on daily average basis. It is higher than the heat calculated theoretically (by considering 10% ash content in 2500MT lignite, burnt in a day, bed ash at 40 % of total ash and ash gets cooled from 850 o C to 120 o C, Sp. Heat of ash– 0.84kJ/kg) due to some amount of carbon getting drained in burning state with ash.  More ash content will result into more heat recovery.  CEP discharge (condensate water) cannot be diverted before or after Gland Steam Cooler & Drain Cooler as it will disturb / block the Gland steam flow which is detrimental to turbine shaft & may leads to tripping of the Unit. Observations from the heat balance study:
  • 8.  ISSN: 2252-8792 IJAPE Vol. 3, No. 2, August 2014 : 105 – 114 112  Generator output increased by 0.34 MW at constant MS Flow, even though vacuum has been deteriorated by 4.0 mbar. If we could maintain the vacuum by switching off one CCW pump (this will stop the bypass flow by 1000 t/h & vacuum will improve) when Condensate temp is nearing to its maximum then additional gain in MW output at generator terminal may be achieved.  The improvement in TG Heat-rate by 5.7 kcal/kWh corresponds to AC outlet temperature or LPH 1 inlet temperature is maximum at 86 o C. This is corresponds to the bed ash unloading in one ash cooler up to 20 mbar combustor dp.  Generator output may be made constant by reducing main steam flow by 1.93t/h at peak temperature of condensate through ash cooler. This will save the steam consumption & in turn the fuel input.  As condensate temperature starts increasing, load shared by low pressure turbine starts increasing, while it starts reducing in inter mediate pressure turbine. High pressure turbine output remains constant throughout. But there is an overall gain in generated MW.  There will be a loss of 3.5 kW in generated MW, if we consider one degree loss of temperature of condensate, for idle hours when no ash is being unloaded.  Extraction steam flow to LPH 1 becomes zero at 76 o C & above temps of condensate; extraction steam flow to LPH 2 never becomes zero while LPH 3 extraction steam flow remains unaffected.  Final temperature gain in condensate water after LPH 3 remains unchanged.  In any case of temperature rise in ash cooler, the pressure of water will always be well above saturation pressure, so there is no chance of steaming inside the coils. Table 4. Risk factors and solution Sr. No. Risk Factors Solution 1 LPT exhaust losses & inter-stage losses may be increased with deteriorated vacuum. There is very minor change in wetness fraction of the steam at extraction points for LPH 1 & exhaust, however exact loss cannot be calculated. 2 Pulsating load may set up in LPT, which is not permissible. Loading variation in LPT will be as per ramp given by OEM (2.5 MW /min). From the data analysis, whenever ash is unloaded, the peak temperature reached in 15 minutes period or more, depending upon the amount of ash. Any change taking place in LPT in 15 minute period cannot be termed as a pulsating load) 3 Vibrations may set up in LPH tubes as condensate temperature changes. This condition may occur only when steaming (flash) takes place inside tubes, but it is not possible in this case at all loads, actual condensate pressure will always be is greater than saturation pressure. 4 Flash may occur in drip piping system / LPH tubes / LPH shell. 1. In the LPHs circuit, this possibility of flashing has been nullified by maintaining a height difference of @ 4.0 m (By installing DC at zero m level), so there is no question of drip flashing at any point. 2. Inside the LPH-1 shell, flash in drip water may occur if temp of condensate at inlet is higher than drip temp coming from LPH 2. This case can be avoided if we unload the ash in controlled manner so that condensate temp at LPH 1 inlet should not exceed from 78 deg C. There is no threat to LPT as drip line is connected to condenser via DC & LPFT, if any back pressure generates, it will go through the drip pipe to condenser. However maximum temperature rise may be addressed while designing the new coils for ash coolers. 5 LPH 1 condensate inlet temp exceeding than design. Tube side design temperature is 150 o C and max condensate temp will be average out to 85o C, when it will be mixed with Condensate outlet flow from other ash cooler, which is not in service. 6 Recovery of heat may be achieved by using any other idea / system – we should not disturb the original thermal system – it may have detrimental effect on the turbine life. As ash unloading instances depend upon many other factors, there is no fixed interval between two instances of ash unloading. Hence, heat from the drained bed ash is non continuous nature. This inconsistent nature of heat availability will not be suitable to any recovery system because every system needs a regular, constant, reliable source of energy for proper & efficient functioning. Earlier we had thought of using it in VAM, but it was not suitable source. So only the turbine thermal cycle is the best place to recover this waste heat. 7 Due to pressure & temperature drop in the condensate circuit (After DC via Ash Cooler to LPH 1) loss of heat when no ash is being unloaded in the circuit may offset the saving. There is a minor loss of enthalpy. It depends upon piping layout, no of bends, no of valves & valve type etc. It has been estimated at 880 kcal/hr - by assuming 1.2 at pressure & 1 o C temperature drop in condensate water, which will be lost during the period when no ash is unloaded. This amount of heat is so negligible when compared with 5 to 6.5 lac kcal hourly average heat. Suppose for the whole day, ash is not unloaded, there will be 21200.0 kcal will be lost and this is equal to 8.0
  • 9. IJAPE ISSN: 2252-8792  Ash Cooler Heat Recovery Under Energy Conservation Scheme (Lalatendu Pattanayak) 113 units of electricity only, which can be recovered in a single smallest instance of ash unloading; however max idle period was found at 10 hrs from the collected data when ash was not unloaded. 8 When condensate will admitted into ash cooler, max temperature rise will be 123 o C (average 109 o C), this will limit the use of both ash coolers at a time. Also there are the chances of ‘flash’ in the system. The temperature mentioned is well below the saturation temperature at that pressure, so there is no chance of ‘flashing’. This situation will arise when heavy amount of ash is being unloaded, certainly it will limit the use of both ash coolers at a time. However such type of incidence is rare. Moreover, if ash is drained in both ash coolers simultaneously, combustor DP cannot be controlled. 9 There will be extended period of cooling cycle of hot ash in ash cooler after each incidence of ash unloading due to increased temp of cooling water( condensate, if modified). However it is a minor variation, but can be sort out while designing the new tube nest of ash cooler. The cold ash temperature will be 15 o C higher than ACW. The loss due to which is negligible. 10 The ash cooler in which ash is being unloaded may need more water in case of heavy amount of ash to avoid any thermal stroke. Through the ash cooler, which is not in service, condensate flow can be throttled to divert additional flow. To achieve this, additional valves (Motorized valves) may be provided so that thermal shock can be avoided. 11 At present ash cooler’s coil design capacity to withstand pressure up to 10 kg/cm2 . Condensate line pressure before de-aerator level control station is @ 16 kg/cm2 . So cooling coils capacity will have to be enhanced at 1.5 times than at present. 12 We will have to keep ACW system always available for situations like BTL & low load conditions or unforeseen situation for a while. For some period of observation, ACW system may be kept as standby available. Later it may be abandoned. 13 Unforeseen situation creation in ash cooler like when speiss valve has become fully open & inoperative, leakage of coils etc. Ash will accommodate in ash cooler up to its normal capacity only, after that the ash inflow will be stopped and temp will start reducing. The max rise in temp of ACW at outlet is found at 123 o C, and mix temp of ACW from both ACs max at 85 o C. However to minimize thermal shock, max condensate may be diverted through the ash cooler which is in problem. 14 What would happen when turbine is at low load? When Unit is running at low load, ash unloading from combustor also reduced in quantity & occasions and condensate flow from CEP also reduced. In this case maximum flow may be diverted to one ash cooler. 15 Heat from the ash is of intermittent nature. Heat from the ash is of intermittent nature as ash unloading instances depend upon many other factors. This inconsistent nature of heat availability is not useful for utilizing it in any other system like VAM; because every system needs a regular, constant, reliable source of energy for functioning, so thermal cycle is the best place to recover this waste heat. REFERENCES [1] P. Gauville, J. Foucher and D. Moreau, "Achievable combustion efficiency with Alstom CFB boilers for burning discarded coal," The Journal of The Southern African Institute of Mining and Metallurgy, vol. 112, pp. 437-447, June 2012. [2] G. Yue, J. Lu and H. Zhang, "Design theory of circulating fluidized bed boilers,in: Jia(Ed.)," in Proceeding of the 18th International Conference on Fluidized Bed Combustion, Toronto, 2005. [3] J. Lv and G. Yue, "The CFB Boilers Operation and Overhaul," Beijing, 2003. [4] E. Carrea, G. Scavizzi and J. Barsin, "Dry Bottom Ash Removal-Ash Cooling vs Boiler Efficiency Effects," in International Joint Power Generation Conference, 1998. [5] K. Cen, M. Ni, Z. Luo, Z. Yan, Y. Chi and M. Fang, Theory design and operation of circulating fluidized bed boiler, Beijing: China Electric power Press, 1997. [6] X. Lu, Large-scale circulating fluidized bed boiler equipment and operation, Beijing: China Electric Power Press, 2006. [7] W. Wang, X. Si, H. Yang, H. Zhang and J. Lu, "Heat-Transfer Model of the Rotary Ash Cooler Used in Circulating Fluidized-Bed Boilers," in Energy Fuels, 2010. [8] B. Zeng, X. Lu and H. Liu, "Influence of CFB (circulating fluidized bed) boiler bottom ash heat recovery mode on thermal economy of units," Energy, vol. 35, pp. 3863-3869, 2010. [9] W. Wang, J. J. Li, S. Yang, X. Si, H. R. Yang, J. F. Lu and G. X. Yue, "EXPERIMENTAL STUDY ON HEAT TRANSFER IN A ROLLING ASH COOLER USED IN THE CFB BOILER," in Proceedings ofthe 20th International Conference on Fluidized Bed Combustion. [10] N. Zhang, F. Sun, X. Ding and X. Huang, "An analysis and Optimization of waste heat Utilization Involving water- cooled ash-slag Discharged from CFB boilers," Journal of Engineering for Thermal Energy and Power, vol. 21(3), pp. 311-316, 2006.
  • 10.  ISSN: 2252-8792 IJAPE Vol. 3, No. 2, August 2014 : 105 – 114 114 [11] "http://www.steag-systemtechnologies.com/ebsilon_professional+M52087573ab0.html," [Online]. BIOGRAPHIES OF AUTHORS Vikar R Gupta: Working as Manager (TS) at SLPP, having work experience of more than 22 years in operation and mentanance of thermal power plants. Holds a degree in Electrical engineering. Interest area of research in energy efficiency of energy systems. Lalatendu Pattanayak: Working as DGM (System Technology dept.) at Steag Energy Services India Pvt. Ltd. Holds a M.Tech degree in Environmental Science and Engineering and Post graduate diploma in Thermal Power Plant Engineering. Interest area of research thermodynamic modeling, power plant optimization and energy efficiency in thermal power plants. Is a member in ASME since February 2014.