SlideShare a Scribd company logo
1 of 117
Download to read offline
Version
June 2015
Add-on Module
JOINTS
Design of Connections in Steel and
Timber Structures
Program Description
All rights, including those of translations, are reserved.
No portion of this book may be reproduced – mechanically, elec-
tronically, or by any other means, including photocopying – with-
out written permission of DLUBAL SOFTWARE GMBH.
© Dlubal Software GmbH 2015
Am Zellweg 2
D-93464 Tiefenbach
Germany
Tel.: +49 9673 9203-0
Fax: +49 9673 9203-51
E-mail: info@dlubal.com
Web: www.dlubal.com
Contents
© Dlubal Software GmbH 2015
1
Contents
Contents Page
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 JOINTS Add-on Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Using the Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Opening JOINTS Add-on Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. General Input Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.3 Loads and Internal Forces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.1 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.2 Internal Forces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.4 National Annex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3. Steel - Column Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
3.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.4 Footing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.5 Base Plate and Welds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.6 Anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3.7 Shear Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.8 Stiffeners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4. Steel - Tower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
4.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.4 Geometry 1 / Geometry 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.5 Geometry, Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.6 Diagonal 1,1 connection / Diagonal 1,2 connection . . . . . . . . . . . . . . 39
4.7 Definition of Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
5. Steel - DSTV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
5.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
5.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
5.4 Connection Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6. Timber - Steel to Timber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
6.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
6.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
6.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
6.4 Load Duration and Service Class. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
6.5 Geometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
6.6 Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
7. Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
8. Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
8.1 Geometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
8.2 Designs - Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
8.3 Design by Load Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
8.4 Design by Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Contents
© Dlubal Software GmbH 2015
2
8.5 Design - Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
8.6 Graphic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
8.7 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
9. Results Evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
9.1 Graphic of Connection in JOINTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
9.2 Graphic of Connection in RSTAB Model . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
10. Printout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
10.1 Printout Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
10.2 Graphic Printout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
10.2.1 JOINTS Graphic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
10.2.2 RSTAB Graphic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
11. General Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
11.1 Design Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
11.2 Units and Decimal Places . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
11.3 Data Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
12. Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
12.1 Steel - Column Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
12.1.1 System and Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
12.1.2 Entry in JOINTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
12.1.2.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
12.1.2.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
12.1.2.3 Internal forces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
12.1.2.4 Footing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
12.1.2.5 Base Plate and Welds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
12.1.2.6 Anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
12.1.2.7 Shear Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
12.1.3 Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
12.1.4 Designs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
12.1.4.1 Part of Joint in Compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
12.1.4.2 Shear Resistance of Joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
12.1.4.3 Welds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
12.2 Timber - Steel to Timber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
12.2.1 System and Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
12.2.2 Cross-Section Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
12.2.3 Designs - Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
12.2.3.1 Steel plate under bending, shear and axial force. . . . . . . . . . . . . . . . . . 99
12.2.3.2 Bearing resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
12.2.3.3 Load-carrying capacity per fastener . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
12.2.3.4 Load-carrying capacity per shear plane per dowel. . . . . . . . . . . . . . 102
12.2.3.5 Block shear failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
12.2.3.6 Effective number of dowels neff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
12.2.3.7 Transversal tension resistance of inclined forces . . . . . . . . . . . . . . . . 108
12.2.3.8 Transversal tension resistance due to moment . . . . . . . . . . . . . . . . . 109
12.2.3.9 Shear in net cross-section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
12.2.3.10 Minimum spacings between fasteners . . . . . . . . . . . . . . . . . . . . . . . . . 113
A. Literature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
B. Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
1 Introduction
© Dlubal Software GmbH 2015
3
1
1 Introduction
1.1 JOINTS Add-on Module
With the introduction of Eurocodes, the design of joints becomes more and more important.
The European standard EN 1993-1-8 [1] describes the designs of steel connections. The design
of timber connections is specified in EN 1995-1-1 [2]. The JOINTS add-on module combines
connection modules developed in the previous RSTAB program versions in a single user interface.
Furthermore, the scope of functions for the joint design has been extended and adapted to comply
with the current requirements.
At present, JOINTS covers steel categories ColumnBase, Tower and DSTV as well as a timber category
Steel to timber connections.
JOINTS Steel - Column Base designs footings of hinged and restrained steel columns.
The Hinged Column Footing category includes the following base plate joint types:
• Simple column base
• Tapered column base
• Column base plate for rectangular hollow sections
• Column base plate for circular hollow sections
The Restrained Column Footing category includes the following layouts of I-sections:
• Simple column base
• Base plate with stiffeners in center of flanges
• Base plate with stiffeners on both sides of column
• Base plate with channel sections
• Bucket footing
JOINTS Steel - Tower designs nominally pinned joints with bolt connections of members used in
lattice towers for the following cases:
• Connection of diagonals without gusset plate 2D
• Connection of diagonals without gusset plate 3D
• Column joint with splices
JOINTSSteel-DSTVdesignsmomentresistantandpinnedI-beamconnectionsinaccordancewith
the German guideline “Typified Connections in Steel Building Constructions” [3]. The resistances
are determined according to DIN EN 1993-1-8 [1].
The Moment Resistant Joints category includes the following layouts:
• End plate without column (IH type)
• Beam joint with end plate (IH type)
• Single-sided beam with end plate (IH type)
• Double-sided beam with end plates (IH type)
• Purlin joint with splices (PM type)
1 Introduction
© Dlubal Software GmbH 2015
4
1
The Simple Joints category includes the following layouts:
• End plate (IS type), or end plate with notching (IK type)
• Angle (IW type), or angle with notching (IK type)
• Long angles (IG type)
JOINTS Timber - Steel to Timber designs timber joints indirectly connected by means of steel
plates.
There are hinged, bending-resistant and semi-rigid dowel connections available for the following
cases:
• Single member
• Continuous member with secondary members
• Connection of multiple single members
The results including dimensions are shown in tables and graphics. Using the design cases, you
can analyze different design variants.
Since the JOINTS add-on module is integrated in the graphical user interface of the main program
RSTAB, all input data of the model as well as the internal forces are already available for design.
Some modules allow you to consider also connection stiffnesses and eccentricities when deter-
mining internal forces. You can visualize the results in the RSTAB work window and include them
in the global printout report.
We wish you enjoyment and success with JOINTS.
Your DLUBAL Team
1 Introduction
© Dlubal Software GmbH 2015
5
1
1.2 Using the Manual
Topics like installation, graphical user interface, results evaluation, and printout are described
in detail in the manual of the main program RSTAB. The present manual focuses on typical features
of the JOINTS add-on module.
The descriptions in this manual follow the sequence and structure of the module's input and result
windows. Chapter 2 describes the input parameters that apply to all steel and timber connections.
The following chapters describe specific input parameters of the individual connections modules.
The final chapter includes design examples.
In the text, the described buttons are given in square brackets, for example [New]. The buttons
are also shown in the left margin. Expressions appearing in dialog boxes, windows, and menus
are set in italics to clarify the explanation.
At the end of the manual, you find the index. However, if you still cannot find what you are looking
for, please use the search function on our blog website www.dlubal.com/blog/en where you can
find a solution in the posts about our add-on modules for joint design.
1.3 Opening JOINTS Add-on Module
RSTAB provides the following options to open the JOINTS add-on module.
Menu
To open the program from the RSTAB menu bar, click
Add-on Modules → Connections → JOINTS.
Figure 1.1: Menu: Add-on Modules → Connections → JOINTS
1 Introduction
© Dlubal Software GmbH 2015
6
1
Navigator
As an alternative, you can open the add-on module in the Data navigator by clicking
Add-on Modules → JOINTS.
Figure 1.2: Data navigator: Add-on Modules → JOINTS
2 General Input Data
© Dlubal Software GmbH 2015
7
2
2 General Input Data
This chapter describes the input parameters that apply to all categories of steel and timber con-
nections. The following chapters describe specific input parameters of the individual connection
modules.
When you open the JOINTS add-on module, a new window appears. In this window, a navigator is
displayed on the left. The upper part of the navigator lists design cases (see Chapter 11.1, page 80)
with selected nodes, the lower part covers windows of a specific module.
The input data is defined in several module windows. When you open JOINTS for the first time,
the following parameters are imported automatically:
• Load cases, load and result combinations, super combinations, and dynamic envelopes
• Materials
• Cross-sections
• Internal forces (in background, if calculated)
To select a window, click the corresponding entry in the navigator. To set the previous or next
window, use the buttons shown on the left. For scrolling in windows, you can also use the function
keys to select the next [F2] or previous [F3] window.
Click [OK] to save the results. Thus, you exit JOINTS and return to the main program. To close the
add-on module without saving the data, click [Cancel].
2.1 General Data
In the 1.1 General Data window, you can define the basic settings necessary for joint design. Use
the filter functions to select a specific type of connection.
Figure 2.1: Window 1.1 General Data
2 General Input Data
© Dlubal Software GmbH 2015
8
2
Material
Figure 2.2: Filter for steel and timber connections
In the Material section, you can define whether a steel or a timber connection is to be designed.
This setting specifies the selection options available in the other window sections.
Joint Group
Figure 2.3: Filter for joint groups of steel material
Figure 2.4: Filter for joint groups of timber material
This window section specifies the connection type. You can select the relevant joint group by
using the drop-down list or by clicking the buttons with the joint icons.
Joint Category
Figure 2.5: Filter for joint categories of column footings
Figure 2.6: Filter for joint categories of steel to timber connection
Use the drop-down list or the buttons to select the relevant joint category.
Joint Type
Figure 2.7: Filter for joint types of hinged column footings
2 General Input Data
© Dlubal Software GmbH 2015
9
2
Figure 2.8: Filter for joint types of dowels
In this window section, you can specify the exact type of the joint. Also here, you can select the
type using the drop-down list or the joint icon buttons.
According to Standard / National Annex
Figure 2.9: Standard and National Annex
Steel connections are designed automatically according to EN 1993-1-8 [1], timber connections
according to EN 1995-1-1 [2]. In the drop-down list to the right of the standard, you can select
the National Annex and thus apply these parameters to designs.
Use the [Edit] button to open a dialog box where you can check the parameters of the selected
National Annex. This dialog box is described in Chapter 2.4 on page 16.
Comment
In this text box, you can enter user-defined notes, for example to describe the current joint.
2 General Input Data
© Dlubal Software GmbH 2015
10
2
2.2 Nodes and Members
In the second window, you can select nodes to be analyzed. In addition, you can define the para-
meters of the members connected to the nodes.
Figure 2.10: Window 1.2 Nodes and Members
Definition Type
You can select nodes using the Importfromstructuremodel option. Thus, the geometric parameters
such as a number and parameters of the connected members are imported automatically from
RSTAB. As an alternative, the joint can be Set manually.
Joint on Nodes No.
In this text box, you can directly enter the numbers of the nodes to be analyzed. Use the [Select]
button to determine the nodes graphically in the RSTAB work window.
Multiple selection of nodes is useful only if they have identical input parameters. If there are
different design conditions, it is not possible to combine the nodes in this window. In such a case,
you have to create a new design case: Click File → New Case in the menu or use the buttons
and below the Parameters section (see next).
If you select Set manually, the data import from RSTAB is blocked. The note User-defined appears
in the corresponding text box. Then, you can enter the Parameters regardless of the model.
Figure 2.11: Setting a joint manually
2 General Input Data
© Dlubal Software GmbH 2015
11
2
Parameters
In this window section, you can define the properties of the components connected to the nodes
specified above.
Figure 2.12: Parameters section with the [Select inactive members] button
Construction Status
In this column, you can set the status of members for design. The selection options depend on
the joint group and the joint category selected in Window 1.1.
Cross-Section Description
For the nodes imported from RSTAB, the member cross-sections are preset.
To change the cross-section, click the entry to activate the text box. To open the cross-section
library, use the button in the text box (see Figure 2.10) or press [F7].
Figure 2.13: Cross-section library
Chapter 4.3 of the RSTAB manual describes how to select cross-sections from the library.
A modified cross-section is highlighted in blue.
2 General Input Data
© Dlubal Software GmbH 2015
12
2
Material Description
When importing a node from RSTAB, the cross-section materials are preset as well.
To change the material, click the entry to activate the text box. To open the cross-section library,
use the button in the text box (see Figure 2.10) or press [F7].
Figure 2.14: Material library
Chapter 4.2 of the RSTAB manual describes how to select materials from the library.
The buttons in the Parameters section have the following functions:
Button Function
Reset default values of the joint
Delete node selected in the table above
Transfer the selected node to a new design case
Transfer all unsuitable nodes to a new design case
Set connection type for all nodes of the design case
Show or hide inactive members in the table
Jump to the RSTAB work window to change the view
Table 2.1: Buttons in the Parameters section
2 General Input Data
© Dlubal Software GmbH 2015
13
2
The buttons and have an important function: If you want to design several nodes with
different boundary conditions, such as a number of connected members or member cross-sections,
these buttons allow for manual or automatic assignment to new design cases. You can define
the parameters for each node in different design cases. Alternatively, you can also click File →
New Case in the menu.
The design cases including data related to a node are displayed at the top of the navigator.
The 1.2 Nodes and Members window always displays the parameters of the nodes selected in
the navigator list. To switch the design case, simply click the relevant entry in the list.
Graphic Window
The graphic window presents a scheme of the connections to be designed. It shows a dynamic
partial view of the model. The node selected in the Parameters section is indicated by an arrow.
The connected members are highlighted.
Figure 2.15: Graphic with selection arrow
You can control the graphic by the same mouse functions as in RSTAB in order to zoom, shift or
rotate the view.
The buttons next to the graphic have the following functions:
Button Function
Show view in the direction of the X-axis
Show view in the opposite direction of the X-axis
Show view in the direction of the Y-axis
Show view in the direction of the Z-axis
Display the isometric view
Reset full view of the graphic
Table 2.2: Buttons in graphic window
2 General Input Data
© Dlubal Software GmbH 2015
14
2
2.3 Loads and Internal Forces
The structure of Window 1.3 depends on the Definition Type that you have selected in the previous
Window 1.2 (see Figure 2.10, page 10).
The data entered in this window always refers to the design case selected in the navigator
on the top left. To switch the design case, simply click the relevant entry in the list.
2.3.1 Loads
If you select the Import from structure model definition type in Window 1.2, you have to define
the load cases or load combinations including internal forces to be applied for the design in
the 1.3 Loads window.
Figure 2.16: Window 1.3 Loads
Existing Load Cases and Combinations
This section lists all load cases as well as load and result combinations created in RSTAB.
JOINTS can also design super combinations and DYNAM cases.
Use the button to transfer the selected entries to the Selected for Design list on the right. Alter-
natively, you can double-click the entries. To transfer the entire list to the right, use the button.
To transfer multiple entries of load cases, click the entries while pressing the [Ctrl] key, as common
for Windows applications. Thus, you can transfer several load cases at the same time.
Load cases marked in red, like LC 5 or LC 6 in Figure 2.16, cannot be designed: This happens when
the load cases are defined without any load data or contain only imperfections. When transferring
such a load case, a corresponding warning appears.
2 General Input Data
© Dlubal Software GmbH 2015
15
2
At the end of the list, several filter options are available. They will help you to assign the en-
tries sorted by load case, load combination, or action category. The buttons have the following
functions:
Select all cases in the list
Invert selection of load cases
Table 2.3: Buttons in the Existing Load Cases and Combinations section
Selected for Design
The column on the right lists the load cases as well as the load and result combinations selected
for design. Use the button or double-click the entries to remove selected items from the list.
Use the button to transfer the entire list to the left.
For a multiple selection, press [Ctrl] and click the corresponding entries.
2.3.2 Internal Forces
If you select the Set manually definition type in Window 1.2 (see Chapter 2.2, page 10), you have
to enter the internal forces to be applied for the design in the 1.3 Internal Forces window.
Figure 2.17: Window 1.3 Internal Forces
LC
The internal forces are managed in a single load case. When you open the window for the first
time, LC 1 is preset.
Use the button to create a new load case. The load cases allow you to specify different
combinations of internal forces for the design.
2 General Input Data
© Dlubal Software GmbH 2015
16
2
Member
In this column, you can enter a member number in order to facilitate the assignment of internal
forces.
Force / Symbol
Both columns display the types of internal forces applied.
Value / Unit
In this column, you can enter values of the internal forces.
To adjust the units and decimal places of the internal forces, use the menu and click Settings →
Units and Decimal Places (see Chapter 11.2, page 82).
The buttons below the table have the following functions:
Create a new load case for additional internal forces
Delete the load case selected above
Table 2.4: Buttons in the 1.3 Internal Forces window
2.4 National Annex
In the upper-right part of the 1.1 General Data window, you can select the National Annex, the pa-
rameters of which should be applied for design (see Figure 2.9 on page 9). Click [Edit] to check
the parameters. The content of the dialog box depends on the material selected (steel or timber
connections).
Steel Joints
Figure 2.18: National Annex Settings - EN 1993-1-8/NA:2010-12 dialog box
2 General Input Data
© Dlubal Software GmbH 2015
17
2
Timber Joints
Figure 2.19: National Annex Settings - EN 1995-1-1:2004/A1:2008 dialog box
These dialog boxes display various factors of the National Annex, for example the material factor,
modification factor, and shear factor. Generally, you cannot change the values as they are codified
in the National Annexes.
Click [New] to create a user-defined National Annex, where you can freely define the factors.
Furthermore, the [Nat. Annex] button is available in all input windows. You can use this button to
open the National Annex Settings dialog box as well.
The buttons in the National Annex Settings dialog box have the following functions:
Button Function
Reset original settings of the program
Import user-defined default settings
Save modified settings as default
Delete user-defined National Annex
Table 2.5: Buttons in the National Annex Settings dialog box
3 Steel - Column Base
© Dlubal Software GmbH 2015
18
3
3 Steel - Column Base
This chapter describes the individual windows of the JOINTS Steel - Column Base module.
The general input parameters are described in Chapter 2.
The input windows of the add-on module appear as soon as you select the Steel material and
the Column Base joint group.
Figure 3.1: JOINTS Steel - Column Base add-on module
The input data always refers to the design case set in the navigator on the top left. To switch
the design case, simply click the relevant entry in the list.
If the entries Footing, Base Plate and Welds, Anchors etc. are missing in the navigator, go to
the 1.2 Nodes and Members window and check if the boundary conditions required for the input
of the column footing are correct. For example, it may be necessary to deactivate the connected
members (see Figure 3.8, page 23).
The input windows of the JOINTS Steel - Column Base module consist of two parts: On the left, you
find the input parameters of the footing component that are illustrated in graphics on the right
(see Figure 3.9, page 24). The upper graphic shows a system sketch of the current parameter,
the lower graphic shows a 3D visualization of the column footing model.
Figure 3.2: 3D visualization of column footing
The buttons below the 3D graphic are described in the following table.
3 Steel - Column Base
© Dlubal Software GmbH 2015
19
3
Button Function
Display or hide dimensions
Display dimension values or symbols
Show view in the direction of the X-axis
Show view in the opposite direction of the X-axis
Show view in the direction of the Y-axis
Show view in the direction of the Z-axis
Display the isometric view
Reset full view of the graphic
Display or hide the irrelevant parts of the window
Table 3.1: Buttons of 3D graphic
3.1 General Data
Figure 3.3: Window 1.1 General Data
3 Steel - Column Base
© Dlubal Software GmbH 2015
20
3
Joint Category
Figure 3.4: Joint category
It is necessary to specify whether you want to design a Hinged or Restrained column footing.
You can use the drop-down list or the buttons with the joint icons to select the category.
Joint Type
The selection options depend on the joint category.
Figure 3.5: Joint Type section of the Hinged Column Footing category
The Hinged Column Footing category covers the following layouts:
Column base plate without stiffening
Tapered column base
Column base plate for rectangular hollow sections
Column base plate for circular hollow sections
Table 3.2: Joint types of hinged column footings
3 Steel - Column Base
© Dlubal Software GmbH 2015
21
3
Figure 3.6: Joint Type section of the Restrained Column Footing category
The Restrained Column Footing category covers the following layouts for I-sections:
Base plate without stiffening
Base plate with stiffeners in center of flanges
Base plate with stiffeners on both sides of column
Base plate with channel sections on both sides of column
and web members
Bucket footing
Table 3.3: Joint types of restrained column footings
3 Steel - Column Base
© Dlubal Software GmbH 2015
22
3
Additional Settings
Figure 3.7: Additional Settings section
If you select the Use the column material for other joint components check box, the material of
the column cross-section is automatically used for the base plate, anchors and shear keys. In this
case, you cannot define the materials separately.
A plastic Force distribution in joint applies. Cast-in anchors are preset as the Anchorage type.
The connection between the steel base plate and the foundation can be made of a Grout layer or
an Anchoring template set in concrete.
By selecting the Simplified Results check box, you can reduce the output data: The program cal-
culates all nodes and load cases that are available for design. Then, JOINTS filters the results and
displays the governing results in the 3.1 Design - Summary window (see Figure 3.3, page 67). Win-
dows 3.2 to 3.4 with the individual designs of each node and load case are not displayed in this
case. Since these results are not processed, the calculation is considerably faster.
3 Steel - Column Base
© Dlubal Software GmbH 2015
23
3
3.2 Nodes and Members
The selection of nodes and members is described in Chapter 2.2 on page 10.
In the Parameters section, you can check the boundary conditions of the connected components.
If there is an Invalid cross-section, you should adjust the cross-section to the joint type set in
Window 1.1.
If several members such as diagonals are connected to one column base node, you can set the sta-
tus of irrelevant members to Inactive.
Figure 3.8: Setting the Inactive status of the diagonal member
3.3 Loads
The entry of loads or internal forces is described in Chapter 2.3 on page 14.
3 Steel - Column Base
© Dlubal Software GmbH 2015
24
3
3.4 Footing
In the 1.4 Footing window, you can specify the foundation parameters and define the position of
the base plate.
Figure 3.9: Window 1.4 Footing
Footing
Inthiswindowsection, youcandefinethematerialanddimensionsofthefoundation. Usethe but-
ton to open the material library, where you can find the properties of various types of concrete.
Grout Layer
Here you can define the grout thickness, the characteristic grout strength, and the friction coeffi-
cient of the grout layer between the base plate and the foundation.
Anchoring Template
If you have selected the cast-in anchors option in the 1.1 General Data window, you can define
dimensions of the plate in this section. In addition, it is possible to set a welded connection of
the anchoring template and base plate.
Additional Parameters
You can specify the parameters of the Eccentricity of base plate in order to arrange the base plate
eccentrically on the footing.
Moreover, you can determine if there is an Edge reinforcement and select the form of it.
The Cracks in concrete check box specifies if the concrete in cracked state is considered for the cal-
culation.
3 Steel - Column Base
© Dlubal Software GmbH 2015
25
3
Restrained Column Footing - Bucket Footing
If you have selected the Bucket footing joint type in the 1.1 General Data window (see Figure 3.6,
page 21), the 1.4 Footing window is displayed as follows:
Figure 3.10: Window 1.4 Footing for the Bucket footing joint type
Click to open the material library where you can select the materials of the foundation.
You can enter the dimensions of the foundation plate and the bucket in the individual text boxes.
3 Steel - Column Base
© Dlubal Software GmbH 2015
26
3
3.5 Base Plate and Welds
In the 1.5 Base Plate and Welds window, you can define the base plate parameters.
Figure 3.11: Window 1.5 Base Plate and Welds
Base Plate
In this window section, you can specify the material and dimensions of the base plate. Click
to open the material library where you can find the properties of various steel grades.
Base Plate Welds
Select the Allow transfer of compression by contact between the column and the base plate check
box to reduce action effects on the weld; the design internal force must be a compression force
in this case. Tension forces are transferred by the welds without exception.
Welds of the column cross-section on the base plate are applied according to the sketch displayed
in the upper right graphic. You can enter the parameters of Weld on flange and Weld on web.
In the case of rectangular and circular hollow sections, you can define the Weld on column.
During the calculation, the add-on module checks also the structural details. For example,
if the weld thickness exceeds the base plate dimensions, the corresponding error message appears.
Figure 3.12: Conflict in structural details
3 Steel - Column Base
© Dlubal Software GmbH 2015
27
3
Restrained Column Footing - Bucket Footing
If you have selected the Bucket footing joint type in the 1.1 General Data window (see Figure 3.6,
page 21), the 1.5 Column window appears as follows:
Figure 3.13: Window 1.5 Column for the Bucket footing joint type
Select the Base plate is welded to the end of column check box if there is a column base plate. Then,
you can enter the base plate and weld parameters as described above.
The Bearing of inner flange check box has an impact on the calculation. If you select the check
box, the program takes into account the elastic compression of the concrete. This affects the load
introduction length.
If necessary, you can adjust the preset value of the Friction coefficient 𝜇 for the tension resistance.
Furthermore, you can specify an eccentric arrangement of the column in the foundation by enter-
ing parameters for the Eccentricity of the column.
3 Steel - Column Base
© Dlubal Software GmbH 2015
28
3
3.6 Anchors
The 1.6 Anchors window determines the parameters of column base anchors.
Figure 3.14: Window 1.6 Anchors
Anchors
The Number of anchors is currently preset with two anchors (hinged column footings) or four
anchors (restrained column footings).
You can define the Diameter and the strength Class of the anchors using the drop-down lists.
There are three Types of anchors available. They affect the design resistance when anchors are
pulled out under tensile stress.
You can control the partial safety factors for the design by specifying the Bond conditions and
the Installation safety.
Depending on the anchor bolt layout, it is possible to consider the Reduction of the determined
design resistance according to [1], Table 3.4, by the factor 𝛽A = 0.85 (see [1], 3.6.1(3)).
Anchor Dimensions
You can arrange the anchors on a base plate by using the Anchor length parameter and entering
the Spacing to the edges of the base plate.
Additional Settings
In this window section, you can specify the shape, size and thickness of Washers and Anchor heads.
The graphic on the right provides a dynamic visualization of the input parameters.
3 Steel - Column Base
© Dlubal Software GmbH 2015
29
3
3.7 Shear Transfer
In the 1.7 Shear Transfer window, you can enter shear key parameters.
Figure 3.15: Window 1.7 Shear Transfer
Shear Key
There are three options available under Shear transferred by: Friction, Anchors, and Shear key.
However, these options cannot be freely combined with each other. Select the corresponding
check box to increase the shear failure resistance. The friction resistance is considered if there is
a compressive force. It reduces the available shear force so that anchor or shear key does not have
to absorb such a high shear.
If you select a shear key, the text boxes of the section above become available and you can select
a cross-section from the RSTAB model. Use the button to define a different cross-section.
The button displays the section properties. Click to change the cross-section subsequently.
In addition, you can use the button to define specific material for the shear key (provided
that the Use the column material for other joint components check box has not been activated in
the 1.1 General Data window). Therefore, the materials used for the column, base plate, and shear
key do not have to be identical.
You can also specify the length of the shear key in the corresponding text box.
Shear Key Welds
In this window section, you can enter the thickness of the circumferential weld that connects
the shear key with the base plate.
3 Steel - Column Base
© Dlubal Software GmbH 2015
30
3
3.8 Stiffeners
The 1.8 Stiffeners window is available for the following joint types:
Tapered column base
Restrained column base plate with stiffeners in center of flanges
Restrained column base plate with stiffeners on both sides of column
Table 3.4: Joint types with stiffeners
Figure 3.16: Window 1.8 Stiffeners
Stiffeners
In this window section, you can define the geometric parameters of the stiffeners. Click to
define the material separately. The Use the column material for other joint components check box in
the 1.1 General Data window must be unselected.
3 Steel - Column Base
© Dlubal Software GmbH 2015
31
3
Trimming
In the case of restrained column base plates with stiffeners, you can enter the length of the vertical
and horizontal trimmings.
Stiffener Welds
In this section, you can define the thickness of stiffener welds according to the joint type. The indi-
vidual parameters are illustrated in the 3D graphic on the right.
Horizontal Stiffener Welds
In the case of hinged column footings with stiffeners, you can use a horizontal stiffener. Select
the check box to activate the text boxes where you can define the thickness and the weld of
the stiffener in compliance with the sketch.
Restrained Column Footing - Base Plate with Channel Sections
(Stiffeners/Crossbars)
If you have selected the Base plate with channel sections joint type in the 1.1 General Data window
(see Figure 3.6, page 21), the 1.8 Stiffeners and Crossbars window appears as follows:
Figure 3.17: Window 1.8 Stiffeners and Crossbars for the Base plate with channel sections joint type
Inbothtabsofthiswindow, youcanselecttheCross-sectionofthechannelstiffenersection. Click
to define a different cross-section. To change the section subsequently, click .
Use the button to select the Material of the cross-section from the library.
The Length and Gap between crossbars text boxes specify the geometric parameters.
4 Steel - Tower
© Dlubal Software GmbH 2015
32
4
4 Steel - Tower
This chapter describes the individual windows of the JOINTS Steel - Tower module. The general
input parameters are described in Chapter 2.
The input windows of the add-on module appear as soon as you select the Steel material and
the Tower joint group.
Figure 4.1: JOINTS Steel - Tower add-on module
The input data always refers to the design case set in the navigator on the top left. To switch
the design case, simply click the relevant entry in the list.
If the entries Geometry 1, Diagonal 1,1 connection etc. are missing in the navigator, go to
the 1.2 Nodes and Members window and check if the boundary conditions of the node are cor-
rect. For example, it may be necessary to adjust the status of connected members (see Figure 4.9,
page 36).
The input windows of the JOINTS Steel - Tower add-on module consist of two parts: On the left,
you find the input parameters of the tower component that are illustrated in graphics on the right
(see Figure 4.10, page 37). The upper graphic shows a system sketch of the current parameter,
the lower graphic shows a 3D visualization of the node.
Figure 4.2: 3D visualization of node
The buttons below the 3D graphic are described in Table 4.1 on page 19.
4 Steel - Tower
© Dlubal Software GmbH 2015
33
4
4.1 General Data
Figure 4.3: Window 1.1 General Data
Joint Category
Figure 4.4: Joint category
JOINTS Steel - Tower covers only the Tower Structure Joints category.
Joint Type
Figure 4.5: Joint type
4 Steel - Tower
© Dlubal Software GmbH 2015
34
4
You can select one of the following joint types:
Uniplanar joint with diagonals on one column leg
Spatial joint with diagonals on both column legs
Butt strap joint with sheets
Table 4.1: Tower - Joint types
1. Alignment / 2. Alignment
Figure 4.6: 1. and 2. Alignment
This section specifies the individual geometric form of a joint in Plane 1 and Plane 2 (for 3D con-
nections).
The letters indicate the number of members on the connection node and their function:
Major chord, minor chord, one strut
Major chord, minor chord, two struts
Major chord, minor chord, three struts
Table 4.2: Alignment
Figure 4.7: K Alignment
4 Steel - Tower
© Dlubal Software GmbH 2015
35
4
Additional Settings
Figure 4.8: Additional Settings section
The program uses the simplified Joint calculation hypothesis according to [1], Clause 3.10.3,
that is applicable for single-leg bolted connection of angles subjected to tensile stress (see [1],
Clause 2.7 (2)).
You can select the Category of connection according to [1], Clause 3.4 using the drop-down list.
There are the categories A to C available for bolted connections loaded in shear.
• Category A: Shear/Hole bearing connections
• Category B: Slip-resistant connections at serviceability limit state
• Category C: Slip-resistant connections at ultimate limit state
In the case of high-strength prestressed bolted connections (Category B or C), you can select also
the Class of friction surface from the drop-down list. The classes with the corresponding friction
coefficient 𝜇 are set in [1], Table 3.7.
4 Steel - Tower
© Dlubal Software GmbH 2015
36
4
4.2 Nodes and Members
The selection of nodes and members is described in Chapter 2.2 on page 10.
In the Parameters section, you can check the boundary conditions of the connected components.
If there is an Invalid cross-section, you should adjust the cross-section to the joint type and to
the alignment defined in Window 1.1.
Figure 4.9: Adjusting the construction status
The columns Angle and Priority provide information about the connected members.
The angles are based on the geometrical conditions of the RSTAB model. If you select the Set manu-
ally definition type in Window 1.2, you can enter a user-defined angle of the connected members.
The priority of struts determines the distribution of windows Diagonal 1,1 connection, Diagonal
1,2 connection etc. The number before the comma assigns the struts to Plane 1 ("1. Alignment")
or to Plane 2 ("2. Alignment" - only for 3D connections). The number after the comma numbers
the members within the respective plane. The order is not design-relevant.
Example: Priority 1,2 means "Plane 1, Strut 2". You can define bolt parameters in the Diagonal 1,2
connection window.
When you click in a row of the table, the selected member is highlighted in the graphic.
4.3 Loads
The input of loads and internal forces is described in Chapter 2.3 on page 14.
4 Steel - Tower
© Dlubal Software GmbH 2015
37
4
4.4 Geometry 1 / Geometry 2
The Geometry window comprises the geometrical boundary conditions of the member on a con-
nection node. There are two separate windows for both planes: The Geometry 1 window refers to
Plane 1 ("1. Alignment"), the Geometry 2 window refers to Plane 2 ("2. Alignment" - only for 3D
connections).
Figure 4.10: Geometry 1 window
Diagonals Orientation
The arrangement of diagonals on a node is preset during the data transfer from the RSTAB model
(see Figure 4.9, page 36). Text boxes of this window section are locked.
If you define the geometry and the internal forces manually, you can enter a user-defined arrange-
ment and orientation of diagonals as well (see figure above). The check boxes and the list entries
describe the connected leg and its position.
Joint Geometry
Joint eccentricity describes the eccentricity of diagonals. It is based on the central axis intersection
of the cross-section. As shown in the system sketch, positive values move the connection in
the direction of the loose column leg, negative values in the direction of the corner angle.
The local Diagonal offset in the direction of the longitudinal member is automatically updated in
the text boxes below.
The graphic on the right provides a dynamic visualization of the geometric parameters.
4 Steel - Tower
© Dlubal Software GmbH 2015
38
4
4.5 Geometry, Plates
If you have selected the Towers - Splices joint type in the 1.1 General Data window (see Figure 4.5,
page 33), the Geometry, Plates window appears.
Figure 4.11: Geometry, Plates window for the Towers - Splices joint type
Joint Geometry
In this window section, you can define the Joint gap size of a butt strap joint between the cross-sec-
tions.
Concerning the splices arrangement, you can select the External plates and/or Internal plates.
The system sketch on the right illustrates the position of the plates.
If you select the Dimensions of plates are calculated from the bolt spacing check box, the text boxes
for entering length and width of plates below the check box are locked.
You can select the Material of plates from the drop-down list or from the material library using
the button.
In the case of different cross-sections, it is possible to Insert pads to external or internal plates in
order to settle the thickness differences.
External/Internal Plates - Plane 1/2
In these text boxes, you can define the Thickness, Length and Width of external or internal plates.
Plane 1 and Plane 2 refer to both angle legs.
If you select the Dimensions of plates are calculated from the bolt spacing check box in the section
above, you can enter only the thickness.
During the calculation, the add-on module checks also the structural details. For example, if the
splice dimensions are too small for the bolts, a corresponding error message appears.
4 Steel - Tower
© Dlubal Software GmbH 2015
39
4
4.6 Diagonal 1,1 connection / Diagonal 1,2 connection
In the Diagonal X,Y connection windows, you can define parameters of diagonals.
There is a separate window for each plane and member. For example, the Diagonal 1,1 connection
window refers to Plane 1 ("1. Alignment") and Strut 1, the Diagonal 1,2 connection window refers
to Plane 1 and Strut 2. The Diagonal 2,1 connection window specifies the parameters of Strut 1 in
Plane 2.
Figure 4.12: Diagonal 1,1 connection window
Bolts
You can select the Class and Diameter of bolts from the relevant drop-down list. Each connection
requires a similar type of bolts.
In the text boxes, you can define the Hole diameter, Number of rows (currently only one row),
Number of bolts in a row as well as the Distance from edges and between the bolts. The system
sketch on the right illustrates the individual parameters.
Welds
This section includes the weld parameters of gusset plates. Since this connection type is not
implemented yet, the text boxes are locked.
4 Steel - Tower
© Dlubal Software GmbH 2015
40
4
4.7 Definition of Fasteners
If you have selected the Towers - Splices joint type in the 1.1 General Data window (see Figure 4.5,
page 33), you can define bolt parameters in the Definition of Fasteners window.
Figure 4.13: Definition of Fasteners window
Bolts
You can select the Class and Diameter of bolts from the relevant drop-down list. Each connection
requires a similar type of bolts.
Both check boxes specify a position of the Shear plane and a bolt type (black bolts or Fit bolts).
You can enter the Hole diameter separately.
Dimensions in Plane 1 / 2
There is an individual section for each angle plane.
You can define the Number of rows (currently only one row), Number of bolts in a row as well as
the Distance from edges and between the bolts in the corresponding text box. The system sketch
on the right illustrates the individual parameters.
5 Steel - DSTV
© Dlubal Software GmbH 2015
41
5
5 Steel - DSTV
This chapter describes the individual windows of the JOINTS Steel - DSTV module. The general
input parameters are described in Chapter 2.
The input windows of the add-on module appear as soon as you select the Steel material and
the Typified joints - DSTV joint group.
Figure 5.1: JOINTS Steel - DSTV add-on module
The input data always refers to the design case set in the navigator on the top left. To switch
the design case, simply click the relevant entry in the list.
If the Connection Type entry is missing in the navigator, go to the 1.2 Nodes and Members window
and check if the boundary conditions of the connection entry are correct. For example, it may be
necessary to deactivate the connected members (see Figure 5.7, page 44).
5.1 General Data
Figure 5.2: Window 1.1 General Data
5 Steel - DSTV
© Dlubal Software GmbH 2015
42
5
Joint Category
Figure 5.3: Joint category
In this window section, you can specify whether you want to design Moment Resistant Joints or
Simple Joints. You can use the drop-down list or the buttons with the joint icons to select the
category.
Joint Type
The selection options depend on the joint category.
Figure 5.4: Joint Type section of the Moment Resistant Joints category
The Moment Resistant Joints category covers the following joint layouts:
End plate without column
Beam joint
Single-sided beam
Double-sided beam
Purlin joint
Table 5.1: Joint types of moment resistant joints
5 Steel - DSTV
© Dlubal Software GmbH 2015
43
5
Figure 5.5: Joint Type section of the Simple joints category
The Simple Joints category covers the following joint layouts:
End plate
Angle
Long angle
Table 5.2: Joint types of simple joints
Additional Settings
Figure 5.6: Additional Settings section
The Export hinge and eccentricity automatically check box provides the option to consider the en-
tered stiffnesses and eccentricities of the typified joints when determining the internal forces:
When you start the [Calculation], the hinge stiffnesses Sj,ini and the eccentricities are transferred to
RSTAB. Then, RSTAB calculates then the internal forces automatically with regard to the modified
boundary conditions. The results are transferred back to JOINTS for further designs.
This option is primarily applicable to moment resistant joints. Thus, you can consider the joint
flexibility during the modeling process.
5 Steel - DSTV
© Dlubal Software GmbH 2015
44
5
5.2 Nodes and Members
The selection of nodes and members is described in Chapter 2.2 on page 10.
In the Parameters section, you can check the boundary conditions of the connected components.
If there is an Invalid cross-section, you should adjust the cross-section to the joint type set in
Window 1.1.
If several members such as beams, splices and diagonals are connected to a node, you can set
the status of irrelevant members to Inactive.
Figure 5.7: Setting the Inactive status of a beam
In the case of the “Wrong angle between members” comment, you should check if the joint
geometry corresponds to the requirements of typified joints.
5.3 Loads
The entry of loads or internal forces is described in Chapter 2.3 on page 14.
5 Steel - DSTV
© Dlubal Software GmbH 2015
45
5
5.4 Connection Types
In the 1.4 Connection Types window, you can define the specific input parameters of the joint
according to the DSTV type catalogue.
Figure 5.8: Window 1.4 Connection Types
The window consists of two parts: On the left, you find the joint parameters that are illustrated
in the graphics on the right. The upper graphic shows a system sketch of the current parameter,
the lower graphic shows a 3D visualization of the joint.
The buttons below the 3D graphic are described in Table 5.1 on page 19.
The upper left section displays the joint layouts according to DSTV guideline [3]. Each Type is
characterized by a specific label and the respective Bolt size and Bolt class.
Select the corresponding check box in the Used column to determine the connection type. The De-
tails section below shows the parameters of these connections. The 3D graphic provides a dynamic
view of the joint geometry.
When you click the [Suggest the best type] button, JOINTS performs a quick layout design and
displays the Utilization of each joint type in the last column (see figure above). It can help you
choose a suitable joint for the design.
Details
In this window section, you can find all information about the selected joint such as cross-section
and end plate geometry, bolts, welds, as well as resistances and stiffnesses.
5 Steel - DSTV
© Dlubal Software GmbH 2015
46
5
Some categories provide additional modification options.
Connection types IH 3 / IH 4
You can arrange the end plate extension above or below. This setting has an impact on the results,
as the reverse moment may be the governing one.
Figure 5.9: IH 3 joint with End plate extended
Connection types IS / IW
Simple joints of the IS type (joints with end plate) and IW type (joints with angles) can be combined
with the IK type (notching).
Figure 5.10: IW joint with Beam treatments of notching (IK type)
In the other text boxes, you can specify the geometric parameters of the notching: Length, Height
and Fillet corner radius.
Figure 5.11: Selecting geometry parameters for notching
For design purposes, the program analyzes the design resistance of the end plate or angle con-
nections (IS/IW) and the resistance of the notching (IK). The lower of both values is the governing
one.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
47
6
6 Timber - Steel to Timber
This chapter describes the individual windows of the JOINTS Timber - Steel to Timber module.
The general input parameters are described in Chapter 2.
The input windows of the add-on module appear as soon as you select the Timber material and
the Steel to timber connection joint group.
Figure 6.1: JOINTS Timber - Steel to Timber add-on module
The input data always refers to the design case set in the navigator on the top left. To switch
the design case, simply click the relevant entry in the list.
If the entries Load Duration and Service Class and Geometry are missing in the navigator, go to
the 1.2 Nodes and Members window and check if the boundary conditions of the node are correct
and the load cases are available for the design. For example, it may be necessary to adjust the
status of connected members (see Figure 6.9, page 36).
6.1 General Data
Figure 6.2: Window 1.1 General Data
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
48
6
Joint Category
Figure 6.3: Joint category
JOINTS Timber - Steel to Timber covers only the Dowels category at this time.
Joint Type
Figure 6.4: Joint type
You can select one of the following joint types:
Main member only
Connection of a member to an existing component
(or multiple members) at any angle
With continuous member
Connection of the maximum of six diagonals to
a continuous beam (Main member and Continuous
member)
Without continuous member
Free definition of nodes with the maximum of
eight connected members
Table 6.1: Dowels - joint types
Cutting - Main Member
Figure 6.5: Cutting - Main Member
The member can be connected to the main member symmetrically or asymmetrically (see Fig-
ure 6.6).
Symmetrical connection at an angle of 45°
Main member cut by connected member
Main member cut at right angle with the member axis
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
49
6
Table 6.2: Connection options - Main Member
Figure 6.6: Symmetrical connection (left) cut by connected member (middle) and at the angle of 45° (right)
Cutting - Connected Members
Figure 6.7: Cutting - Connected Members
Two web members can be connected by a symmetrical or continuous cutting.
Symmetrical cutting
Continuous cutting
Table 6.3: Connection options - Connected Member
Figure 6.8: Continuously connected member
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
50
6
According to Standard / National Annex
Figure 6.9: According to Standard / National Annex section
The design-relevant factors are preset according to the Standard and the National Annex (see
Figure 6.19, page 17). If you want to apply user-defined factors for designs, click the button to
create a new National Annex. Then, you can adjust the factors individually in the National Annex
Settings dialog box.
Figure 6.10: National Annex Settings dialog box , Dowels tab
The Dowels tab allows you to specify the user-defined minimum spacing between the dowels as
well as the minimum spacing of dowel groups loaded by moment. For example, the adjustment is
necessary for the connection system of BSB company, the approval of which is based on different
values. The user-defined minimum spacings between dowel groups are reasonable for dowel
circles of a frame joint, for instance. They are not clearly defined in the design standard.
In the Other Settings tab, you can adjust the shear correction factors kcr, if necessary.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
51
6
Additional Settings
Figure 6.11: Additional Settings section
You can define the steel plate and dowel materials using the drop-down lists and the buttons.
If you select the SFS intec dowel system WS-T check box, the materials are preset according to
manufacturer approval.
Spacing between
dowel rings
If you select the Check minimum spacing between dowels in dowel group loaded by moment check
box, the program analyzes also the minimum spacing between the individual fastener groups
during the calculation. This applies to both circular and rectangular joints.
After the calculation, you find the design of all minimum spacings under "Design Details".
Figure 6.12: Details of Design No. 6510: Minimum spacing check
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
52
6
To check deformation of the whole connection, select Check contact of members after deformation.
In the 1.5 Geometry window, you can define the distance between timber members using the
parameter og.
Figure 6.13: Check contact of members after deformation
The design 6530 checks whether the total deformation of the connection is greater that the dis-
tance og defined. If the design is not fulfilled, the members are in contact.
These contact properties are not considered in the JOINTS add-on module by default. Therefore,
you should take the appropriate measures if the design was not fulfilled.
The Design of main member dowel group from the sum of connected member internal forces option
checks whether the design is performed using the corresponding internal forces at a member end
or the internal forces resulting from two or more connected members on a node. This option is
not available for the Main member only joint type.
Figure 6.14: Internal forces on member
For internal forces in the figure above, the axial force of −238.62 kN and the shear force of −9.60 kN
are used on the upper flange without the Sum of internal forces option. This option is useful when
transferring the axial force of a connection directly to the support, for example.
However, the resulting axial and shear force are used with the Sum of internal forces option in order
to design the eaves node.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
53
6
6.2 Nodes and Members
The selection of nodes and members is described in Chapter 2.2 on page 10.
In the Parameters section, you can check the boundary conditions of the connected components.
You can also change the Status here, if necessary.
Figure 6.15: Window 1.2 Nodes and Members - Adjusting status of members
The columns Angle and Priority provide information about connected members.
The angles are based on the geometrical conditions of the RSTAB model. If you select the Set manu-
ally definition type in Window 1.2, you can enter a user-defined angle of the connected members.
When you click in a row of the table, the selected member is highlighted in the graphic.
Eaves node connection
This window is especially important for the entry of eaves node connection. If the upper chord
should continue, as shown in the figure on the left, you have to define it as a main member
(the Without continuous member joint type has to be previously selected in Window 1.1).
Figure 6.16: Eaves node with continuous upper chord
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
54
6
If there are more than two members connected to a node, you can define the Status by using one
of the following options:
• Main Member - controls all other members as well as cutting and the priority of it
• Continuous Member - available only for With continuous member joint type
• Connected Member - assigns a lower priority to the other member (struts, splices)
• Inactive - excludes the member from design
In the following example, more members than allowed are connected to a node. Also the angle of
Member 26 is too small. The connection geometry is functional only if the status of Member 26 is
set to Inactive.
Figure 6.17: Functional connection geometry due to inactive member
The following limits apply to definition of members and web members:
• Minimum member length: 42 cm
• Minimum angle between members: 15°
For the Main member only joint type, it is theoretically possible to connect an infinite number of
members to a node (see the following figure). This can be advantage if you want to analyze only
one joint of complex connection geometry. You can freely select the inclination, perimeter and
eccentricity of the Main member only joint type.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
55
6
Figure 6.18: Connection of multiple members using the Main member only joint type
6.3 Loads
The entry of loads and internal forces is described in Chapter 2.3 on page 14.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
56
6
6.4 Load Duration and Service Class
The humidity-dependent strength changes of the anisotropic construction material timber are
determined by the Load Duration Class (LDC) and the Service Class (SECL).
Figure 6.19: 1.4 Load Duration and Service Class window
Loads
The window lists all loads selected for design in the 1.3 Loads window. The combinations are
displayed including the related load cases.
Description
Load case descriptions facilitate the classification.
Load Type
This column shows action types of load cases that you have defined in RSTAB. They are fundamental
for presettings in the next column.
Load Duration Class LDC
For design purposes, you should assign the loads and their superpositions to a specific load
duration class. The classification of the effects is defined in [2], Table 2.1.
You can change the load duration class of load cases and result combinations using the drop-down
list. The classification of load combinations and OR result combinations is automatically preset,
taking into account the principal actions or the included load cases.
The load duration class is important for determination of the modification factor 𝑘 𝑚 𝑜𝑑 that has
an impact on strength properties of the material (see [2], Table 3.1). You can check the factor 𝑘 𝑚 𝑜𝑑
in the National Annex Settings dialog box and adjust it, if necessary (see Figure 6.19, page 17).
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
57
6
Service Class (SECL)
The service classes allow you to assign strength parameters with regard to the environmental
conditions. The service classes are specified in [2], Clause 2.3.1.3, for example.
All members are assigned to the same service class by default. To assign the objects to different
service classes, select the Different check box. Then, click the [Edit] button to open the following
dialog box.
Figure 6.20: Assign Members to Corresponding Service Classes dialog box
Here you can individually distribute the members in the service classes. The buttons next to
the text boxes facilitate the assignment. They have the following functions:
Button Function
Select members graphically in RSTAB work window
Assign all members to the service class
Assign not yet listed members to the service class
Table 6.4: Buttons in the Assign Members to Corresponding Service Classes dialog box
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
58
6
6.5 Geometry
In the 1.5 Geometry window, you can define the parameters of steel plates and dowels.
Figure 6.21: Window 1.5 Geometry
The window consists of two parts: On the left, you find the input parameters of a joint component
that are illustrated in the graphics on the right. The upper graphic shows a system sketch of
the current parameter, the lower graphic shows a 3D visualization of the node.
The buttons below the 3D graphic are described in Table 6.1 on page 19.
Steel Plates
You can define steel plate properties in this window section. Please note the following:
• You can define the maximum Number of five slotted sheets.
• Thickness of steel plate must be between 5 mm and 40 mm (for SFS: 3 mm).
• Distance from dowels to plate edge must be greater than 1.2 d (see [1], Table 3.4).
• Generally, the Width of slot is the same as the thickness of the plate. If the connection was
produced with tolerances, you can increase the thickness of plate by a maximum of 1 mm.
When using the SFS intec systems, you should keep the limit value of 2 mm. This setting makes
no difference for the design because there are only the geometry limitations requested.
• You can design the plates also as side plates. For this, you need to design at least two slotted
sheets.
The modified slotted plate layouts are visualized in the dynamic graphic.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
59
6
In the case of using more than one slotted steel plate, there is often a problem when generating
predominant failure modes according to [2], Clause 8.2.3, Figure 8.3. The predominant (govern-
ing) failure mode of fasteners in the respective joint has to be compatible with any other mode.
Therefore, the combination of failure modes (c), (f) and (j/l) with the other failure modes is not
allowed.
Figure 6.22: Failure modes according to [2], Figure 8.3
JOINTS always checks the bearing resistance in the inner and the outer section of a multishear
connection. For sections on the outer plate edge, it checks the failure modes (f), (g) and (h) for
both thick and thin steel plates. The modes according to [2], Formula (8.9) and (8.10) are identical
in this case.
In the middle part, the program analyzes the failure cases according to [2], Formula (8.12) and
(8.13). Also here, there is a distinction between thick steel plates in modes (l), (m), and thin steel
plates in modes (j), (k).
Figure 6.23: Failure modes: green dashed line (f), (g) and (h); purple dashed line (l), (m) or (j), (k)
JOINTS always determines the governing failure mode of each joint. If there is a thin sheet plate
with the governing failure mode (j) on inner (purple) shear planes and the mode (g) on outer
(green) shear planes, the calculation is not possible. However, if the mode (f) is the governing one,
the calculation will be performed.
Connection Geometry
This window section describes the dowel parameters. You can enter the data for each member
separately. Use the drop-down list or the buttons to display the individual member.
• You can define the Pattern of the dowel group as a rectangle or as a circle.
• The dowel Diameter can be set between 6 mm and 30 mm. If you have selected the SFS intec
dowel system in Window 1.1, the diameter is set to 7 mm by default.
• If you want to define the dowel length lower than the cross-section thickness (in the case
of fire resistance, for example), you need to enter the Plug length. Thus, the dowel length is
reduced automatically.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
60
6
Circular dowel pattern
You can define several dowel circles. The Number of dowel circles is limited by the cross-section
height. In the text boxes below, you can define the Number of dowels in circle.
Figure 6.24: Defining number of dowel circles
Rectangular dowel pattern
In the case of rectangular dowel arrangement, you can define the Number of dowel columns in
the 𝑥-direction and the Number of dowel rows in the 𝑧-direction.
Figure 6.25: Defining number of dowel columns
You can also select the Staggered rows option to improve the crack behavior of the joint.
The Method of dowel group placement can be targeted to the minimum dowel spacing or to the
minimum edge distance. In addition, there is the option of user-defined placements.
The Orientation of dowel columns and rows includes the following options:
• Basic - Orientation to the local member coordinate system
• Rotated - Orientation to the global coordinate system
• Slanting - Orientation to edges with staggered rows
• User-defined - Free definition of inclination and strain
If the Dowel group reinforced by screws is secured against cracks, it is not necessary to reduce
the effective number of dowels. In that case, you have to specify the reinforcement parameters
separately. If you use the reinforcement, JOINTS checks the tension failure of bolts according to
[2], Clause 8.7.2.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
61
6
The Main member only joint type allows you to cut the member at any angle and apply the joint to
a reinforced concrete wall, for example.
Figure 6.26: Defining cutting angle
For the connected web members of a truss, you can define Member eccentricity, which deter-
mines the member contour geometrically. The local member coordinate system is displayed in
the graphic.
Figure 6.27: Defining member eccentricity
Click the [Details] button below the section (see Figure 6.27) to open the Details - List of Dowels
dialog box. In this dialog box, you can deactivate the individual dowels or adjust the dowel
diameter.
Figure 6.28: Details dialog box
The figure above shows the unselected Activity of Dowel No. 1.
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
62
6
6.6 Details
In the Details dialog box, you can specify the other design settings. This dialog box is available in
all windows of the add-on module under the [Details] button.
Figure 6.29: Details dialog box
Design Value Settings
IfyouCreatedesignvaluebyeditingcharacteristicload-carryingcapacity 𝐹 𝑣,𝑅 𝑘, thedesignresistance
is adapted to the semi-probabilistic safety concept using the factors 𝑘 𝑚 𝑜𝑑 and 𝛾 𝑀 .
The design value of the load-carrying capacity per dowel and slotted sheet is then:
𝐹 𝑣,𝑅 𝑑= 𝑘 𝑚 𝑜𝑑 ⋅
𝐹 𝑣,𝑅 𝑘
𝛾 𝑀
(6.1)
Alternatively, you can Create design value by editing characteristic embedment strength 𝑓ℎ,𝑘 and
characteristic fastener yield moment 𝑀 𝑦,𝑅 𝑘. The embedment strength and the yield moment are
adjusted to the partial safety factor for timber or steel.
Embedment strength of timber:
𝐹ℎu�,𝑑 = 𝑘 𝑚 𝑜𝑑 ⋅
𝑓ℎu�,𝑘
𝛾 𝑀
(6.2)
Yield moment of dowels:
𝑀 𝑦,𝑅 𝑑=
𝑀 𝑦,𝑅 𝑘
𝛾 𝑀 0
(6.3)
6 Timber - Steel to Timber
© Dlubal Software GmbH 2015
63
6
Generation to Structural Model
The eccentricities available due to geometric parameters of JOINTS connections can be used also
for modeling. The Generate member eccentricity check box allows you to export the member data
to RSTAB. However, no other structural model is created there. In fact, the eccentricity is transferred
to RSTAB as a member property when you start the JOINTS calculation. Using the modified model,
the program determines the internal forces for design. This option is possible for all members
where you can define the eccentricity. In the case of deleted or modified eccentricity, this is taken
into account as well.
You can check the generated eccentricities in the Edit Member Eccentricities dialog box in RSTAB.
The values are not editable.
Figure 6.30: Generated member eccentricity in RSTAB
Options
If you select the Load capacity of single dowel check box, the minimum timber thickness is checked
according to formula (NA.116). The ultimate limit state design is performed then according to
formula (NA.115), which corresponds to the simplified design. If you check the failure criteria
according to Johansen, this simplified design is not necessary.
If you select the Reduction of timber tensile strength check box, the tensile strength of timber is
reduced by 60 % in the bending and compression design according to [2], Clause 6.2.3. You can
avoid this reduction if you prevent the connection from warping (for example by using a guide
pin).
7 Calculation
© Dlubal Software GmbH 2015
64
7
7 Calculation
You can start the calculation in all input windows of the JOINTS add-on module using the [Calcula-
tion] button.
JOINTS searches for the results of the load cases, load combinations and result combinations to
be designed. If these cannot be found, the program starts the RSTAB calculation to determine
the design-relevant internal forces. If you have selected the direct input of the internal forces (see
Chapter 2.3.2, page 15), the RSTAB results are not relevant for the design.
You can also start the calculation in the RSTAB user interface: The To Calculate dialog box (menu
Calculate → To Calculate) lists design cases of the add-on modules such as load cases and load
combinations.
Figure 7.1: To Calculate dialog box
If the JOINTS design cases are missing in the Not Calculated section, select All or Add-on Modules
in the drop-down list below the section.
Use the button to transfer the selected JOINT cases to the list on the right. Click [OK] to start
the calculation.
To calculate a design case directly, use the drop-down list in the toolbar: Select the JOINTS design
case and click [Show Results].
Figure 7.2: Direct calculation of a JOINTS case in RSTAB
Subsequently, you can see the design process in a separate dialog box.
8 Results
© Dlubal Software GmbH 2015
65
8
8 Results
The 3.1 Design - Summary window is displayed immediately after the calculation.
Figure 8.1: Result window with designs, design ratios and design details
The result data always refers to the design case set in the navigator on the top left. To switch
the design case, simply click the relevant entry in the list.
The content of the result windows is adapted to the results of the different JOINTS modules.
The sequence and the concept of the windows are the same.
Window 2.1 shows an overview graphic including geometric parameters of the connection com-
ponents.
Result windows 3.1 to 3.3 display the designs sorted by different criteria. Window 3.4 lists the in-
termediate values of the individual designs.
Window 4.1 shows a graphic of the connection including all geometry details, which can be printed
as well.
Window 5.1 lists notes that are relevant for the design.
You can select each window by clicking the corresponding entry in the navigator. To set the pre-
vious or next window, use the buttons shown on the left. You can also use the function keys to
select the next [F2] or previous [F3] window.
Click [OK] to save the results. Thus, you exit the JOINTS add-on module and return to the main
program.
Chapter 8 - describes the different result windows one by one. The evaluation of and checking
results is described in Chapter 9 - , page ?? ff.
8 Results
© Dlubal Software GmbH 2015
66
8
8.1 Geometry
This window lists all geometry parameters of the connection.
Figure 8.2: Window 2.1 Geometry
Click to display the list entries and to hide them, as common for Windows applications.
The graphic shows the component selected in the list including the parameters.
The buttons are described in Chapter 9 - on page 74.
8 Results
© Dlubal Software GmbH 2015
67
8
8.2 Designs - Summary
This window lists the maximum design ratios of all designed nodes. The internal force ratios of
the governing load cases and combinations are sorted by design type.
Figure 8.3: Window 3.1 Designs - Summary
Governing Node
This column displays the number of the node with the highest design ratio for the design type
indicated in column E.
Governing Load
In this column, you find the numbers of the load cases or load combinations with the internal
forces resulting in the maximum design ratio.
Design Ratio
Columns C and D display the design conditions according to EN 1993-1-8 [1] or EN 1995-1-1 [2].
The length of the colored bars represents the respective design ratio.
Design According to Formula
This column displays the individual designs according to [1] or [2]. Design numbers of
the JOINTS Timber - Steel to Timber module are defined in Table 8.5 on page 99.
Design Details
In this window section, you can find the detailed information on the design parameters of the entry
selected above.
8 Results
© Dlubal Software GmbH 2015
68
8
8.3 Design by Load Case
Theupperpartofthewindowliststhegoverningdesignssortedbyloadcaseandloadcombination.
The lower part includes detailed information on the internal forces and design parameters of the
load case selected above.
Figure 8.4: Window 3.2 Design by Load Case
Description
This column provides the descriptions of the load cases and load combinations used for designs.
Node No.
This column displays the number of the node with the maximum design ratio of the designed
actions.
Design
Columns C and D display the design conditions according to [1] or [2]. The length of the colored
bars represents the respective design ratio.
Design According to Formula
This column lists the individual equations of the Standard that has been used for the designs.
8 Results
© Dlubal Software GmbH 2015
69
8
8.4 Design by Node
Figure 8.5: Window 3.3 Design by node
This window displays the maximum design ratios of the designed nodes.
8 Results
© Dlubal Software GmbH 2015
70
8
8.5 Design - Details
Figure 8.6: Window 3.4 Design - Details
This result window lists all individual designs including design ratios used for the connection.
The section below provides detailed information on the design parameters selected above.
8 Results
© Dlubal Software GmbH 2015
71
8
8.6 Graphic
This window shows a graphic of the connection including all components.
Figure 8.7: Window 4.1 Graphic
The Components to Display section lists all components of the connection. You can display or hide
the individual components using the corresponding check boxes.
Click to display the subentries. In this way, you can also display the Dimensions and Outlines of
the particular components.
The graphic view is dynamic. The mouse functions known from RSTAB allow you to zoom, shift or
rotate the view.
The buttons are described in Chapter 9 - on page 74.
8 Results
© Dlubal Software GmbH 2015
72
8
8.7 Notes
Figure 8.8: Window 5.1 Notes
The last result window displays the notes that are important for the joint design.
9 Results Evaluation
© Dlubal Software GmbH 2015
73
9
9 Results Evaluation
Windows 3.1 to 3.4 display the results sorted by various criteria. The buttons below facilitate
the evaluation.
Figure 9.1: Buttons for results evaluation in tables
The buttons have the following functions:
Button Description Function
View Mode Jump to the RSTAB work window to change the view
Exceeding Display only rows with a ratio greater than 1 (design not fulfilled)
Color Bars Display or hide colored relation scales in the result windows
Excel Export
Export the table to MS Excel / OpenOffice
→ Chapter 11.3, page 83
Table 9.1: Buttons in result windows 3.1 to 3.4
9 Results Evaluation
© Dlubal Software GmbH 2015
74
9
9.1 Graphic of Connection in JOINTS
Each result window shows a dynamic graphic of the connection. It provides an overview and
illustrates the parameters.
Figure 9.2: Graphic of connection
The buttons below the graphic have the following functions:
Button Function
Display or hide dimensions
Display dimension values or symbols
Show view in the direction of the X-axis
Show view in the opposite direction of the X-axis
Show view in the direction of the Y-axis
Show view in the direction of the Z-axis
Display the isometric view
Reset full view of the graphic
Display or hide the irrelevant parts
Print the current 3D graphic
Table 9.2: Graphic buttons in result windows
Use the mouse functions to zoom, shift or rotate the view. These functions are described in
Chapter 3.4.9 of the RSTAB manual.
Use the [Show unselected parts transparent] button to display only the selected components
including dimensions, for example anchors.
9 Results Evaluation
© Dlubal Software GmbH 2015
75
9
Figure 9.3: Show Unselected Parts Transparently button
Click to print the graphic.
9 Results Evaluation
© Dlubal Software GmbH 2015
76
9
9.2 Graphic of Connection in RSTAB Model
The graphic of the connection can be also displayed in the RSTAB model: Click [OK] to close
the JOINTS module. Then, select the JOINTS load case in the RSTAB menu bar.
The RSTAB work window displays the connections in 3D rendering.
Figure 9.4: Displaying connections in RSTAB work window
Similarly to the display of internal forces, the [Show Results] button displays or hides the module
results.
RSTAB does not provide a Results navigator for the JOINTS design cases. Furthermore, the RSTAB
tables are not relevant for JOINTS.
You can use the View Mode option (see RSTAB manual, Chapter 9.7.1) to filter the nodes of the con-
nection.
You can print the graphic of the connection directly or send it to the printout report (see Chap-
ter 10.2, page 77).
10 Printout
© Dlubal Software GmbH 2015
77
10
10 Printout
10.1 Printout Report
Similarly to RSTAB, the program generates a printout report of the JOINTS results, to which you can
add graphics and descriptions. The selection in the printout report determines what data from
the connection module will be included in the printout.
The printout report is described in the RSTAB manual. In particular, Chapter 10.1.3.5 Selecting
Data of Add-on Modules describes how to select input and output data from add-on modules for
the printout report.
For complex structural systems with many design cases, it is recommended to split the data into
several printout reports, thus allowing for a clearly-arranged printout.
The parameters of input windows 1.4 to 1.8. are summarized in the 1.2.2 Geometry Details table of
the printout report.
Figure 10.1: Printout report including Table 1.2.2 Geometry Details
10.2 Graphic Printout
You can print the graphics of the JOINTS add-on module as well as of the RSTAB work window.
10.2.1 JOINTS Graphic
To print the graphic, use the [Print] button that is available in the 2.1 Geometry window and in
the 4.1 Graphic window on the right below the graphic (see Figure 10.2, page 74).
Click this button to open the following printout dialog box.
10 Printout
© Dlubal Software GmbH 2015
78
10
Figure 10.2: Graphic Printout dialog box, General tab
This dialog box is described in the RSTAB manual, Chapter 10.2. There you can find the description
of the Options tab as well.
If there are several printout reports available, you can select the number of the target report in
the list.
In order to add several graphics in the printout report consecutively, you should unselect the Show
printout report on [OK] check box.
Figure 10.3: Connection graphic in the printout report
10 Printout
© Dlubal Software GmbH 2015
79
10
10.2.2 RSTAB Graphic
In RSTAB, you can add every picture that is displayed in the work window to the printout report or
send it directly to a printer. In this way, you can prepare the connections displayed in the RSTAB
model for the printout as well.
To print the currently displayed graphic of the connection, click
File → Print Graphic
in the menu or use the toolbar button shown on the left.
Figure 10.4: Print Graphic button in RSTAB toolbar
The Graphic Printout dialog box appears, as shown in Figure 10.2.
You can move the graphic anywhere within the printout report by using the drag-and-drop func-
tion.
To adjust a graphic subsequently in the printout report, right-click the relevant entry in the printout
report navigator. The Properties option in the shortcut menu opens the Graphic Printout dialog
box, providing various options for adjustment.
Figure 10.5: Graphic Printout dialog box , Options tab
11 General Functions
© Dlubal Software GmbH 2015
80
11
11 General Functions
This chapter describes useful menu functions as well as export options for the designs.
11.1 Design Cases
Design cases allow you to group members for a design. In this way, you can combine connec-
tion nodes with similar parameters or analyze members with particular design specifications (for
example materials, internal forces).
If the conditions of designed nodes are different in terms of the cross-sections, dimensions, number
of bolts etc., you have to create a new design case. You cannot specify all entries in a single design
case.
In the 1.2 Nodes and Members window, you can click the [Transfer the node to a new case] button
or the [Transfer unsuitable nodes to new case] button to quickly create new design cases (see
Figure 11.10, page 10). Then you can define the node-specific parameters.
The design cases are displayed in the navigator on the top left. To switch the design case, simply
click the relevant list entry. To display JOINTS design cases, you can also click the relevant entry in
the load case list in the menu toolbar of RSTAB.
Create New Design Case
To create a new design case, use the JOINTS menu and click
File → New Case.
The following dialog box appears:
Figure 11.1: New JOINTS Case dialog box
In this dialog box, enter a Number (that is still available) for the new design case. The corresponding
description makes the selection from the load case list easier.
Click [OK] to open the 1.1 General Data window in the JOINTS add-on module where you can enter
the design data.
Rename Design Case
To change the description of a design case, use the JOINTS menu and click
File → Rename Case.
The following dialog box appears:
Figure 11.2: Rename JOINTS Case dialog box
In this dialog box, you can specify a different Description as well as a Number of the design case.
11 General Functions
© Dlubal Software GmbH 2015
81
11
Copy Design Case
To copy the input data of the current design case, use the JOINTS menu and click
File → Copy Case.
The following dialog box appears:
Figure 11.3: Copy JOINTS Case dialog box
Define the Number and, if necessary, a Description of the new case.
Delete Design Case
To delete design cases, use the JOINTS menu and click
File → Delete Case.
The following dialog box appears:
Figure 11.4: Delete Case dialog box
You can select a design case in the list of Available Cases. To delete the selected case, click [OK].
11 General Functions
© Dlubal Software GmbH 2015
82
11
11.2 Units and Decimal Places
Units and decimal places of RSTAB and add-on modules are managed in one dialog box. To open
the corresponding dialog box, use the JOINTS menu and click
Settings → Units and Decimal Places.
The following dialog box appears which you already know from RSTAB. The JOINTS module is
preset in the Program / Module list.
Figure 11.5: Units and Decimal Places dialog box
You can save the settings as a user-defined profile to reuse them in other models. These functions
are described in Chapter 11.1.3 of the RSTAB manual.
11.3 Data Transfer
You can use the input and output data of the JOINTS add-on module also in other programs.
Clipboard
To copy cells selected in the result windows to the Clipboard, use the keys [Ctrl]+[C]. Press [Ctrl]+[V]
to insert the cells, for example in a word processing program. The headers of the table columns
will not be transferred.
Printout Report
You can print the data of JOINTS into the global printout report (see Chapter 10.1, page 77) and
export them subsequently. For this, click
File → Export to RTF.
This function is described in the RSTAB manual, Chapter 10.1.11.
11 General Functions
© Dlubal Software GmbH 2015
83
11
Excel / OpenOffice
JOINTS provides a function for directly exporting data to MS Excel, OpenOffice.org Calc, or to
the CSV file format. To open the corresponding dialog box, click
File → Export Tables.
The following export dialog box appears.
Figure 11.6: Export of Tables dialog box
When you have selected the relevant options, you can start the export by clicking [OK]. Excel or
OpenOffice will be started automatically, you do not need to open the programs first.
Figure 11.7: Results in Excel
12 Examples
© Dlubal Software GmbH 2015
84
12
12 Examples
This chapter presents two examples of a joint design in the JOINTS add-on module. For more
examples, see the verification examples on our website: www.dlubal.com/en/examples.aspx
12.1 Steel - Column Base
A hinged column footing is analyzed according to EN 1993-1-8 [1] and EN 1992-1-1 [4].
The example was published in the book “Stahlbau nach EC3” [5], page 261.
12.1.1 System and Loads
Figure 12.1: System and load according to [5]
System
Hinged internal column
Column
Cross-section HE A 200, Steel S 235 JR
Depth hc 190 mm
Width bc 200 mm
Flange thickness tfc 10 mm
Web thickness twc 6.5 mm
Root fillet radius rc 18 mm
Cross-sectional area Ac 53.8 cm3
Table 12.1: Column cross-section
Base plate
Thickness tp 40 mm
Width bp 220 mm
Depth hp 210 mm
Extension u 10 mm
Weld on flange af 4 mm
Weld on web aw 4 mm
Table 12.2: Base plate
12 Examples
© Dlubal Software GmbH 2015
85
12
Loads
Axial force NEd 580 kN
Shear force VEd 100 kN
Table 12.3: Loads
12.1.2 Entry in JOINTS
12.1.2.1 General Data
First of all, a new model is created in RSTAB. Then, we can directly open the JOINTS add-on module.
The following input data is defined in the 1.1 General Data window:
Figure 12.2: JOINTS Window 1.1 General Data
The design is performed according to Eurocode with DIN factors of the German National Annex.
The example concerns the Column Base joint group, the Hinged Column Footing joint category
and the Simple column base joint type.
12 Examples
© Dlubal Software GmbH 2015
86
12
12.1.2.2 Nodes and Members
The column cross-section and the material are defined in the 1.2 Nodes and Members window.
Figure 12.3: Window 1.2 Nodes and Members
The definition type is changed to Set manually.
The cross-section HE-A 200 and the material Steel S 235 JR are selected from the libraries using
the button.
A query appears that should be confirmed by clicking [Yes].
Figure 12.4: RSTAB query
12 Examples
© Dlubal Software GmbH 2015
87
12
12.1.2.3 Internal forces
The loads are defined in the 1.3 Internal Forces window (compression force with negative sign).
Figure 12.5: Window 1.3 Internal Forces
12.1.2.4 Footing
The 1.4 Footing window specifies the footing parameters.
Figure 12.6: Window 1.4 Footing
The Concrete C20/25 class of concrete was selected in the library using the button.
12 Examples
© Dlubal Software GmbH 2015
88
12
The grout thickness is set to 0.02 m. It is possible to apply the same value also for the characteristic
grout strength.
Foundation length and width are set to 1.0 m. Foundation depth can be reduced to 0.40 m:
ℎ ≥ √𝐴 𝑐,1 − √𝐴 𝑐,0
𝐴 𝑐,0 = ℎ 𝑐 𝑏 𝑐 = 190 mm ⋅ 200 mm = 38,000 mm2
𝐴 𝑐,1 = min (1.0 ⋅ 1.0; 9𝐴 𝑐,0) = 342,000 mm2
ℎ ≥ 390 mm ⇒ selected: ℎ = 400 mm
12.1.2.5 Base Plate and Welds
The base plate is made of STEEL S 235 JR.
With the extension u = 10 mm, the dimensions are defined as follows:
Figure 12.7: Window 1.5 Base Plate and Welds
According to Table 12.2, the base plate thickness is set to 40 mm. Both thickness of weld on flange
and weld on web are set to 4 mm.
12 Examples
© Dlubal Software GmbH 2015
89
12
12.1.2.6 Anchors
Since the example of [5] includes no information about anchors, the Straight ribbed rod anchors
with diameter of M18 and 5.6 strength class were selected.
Figure 12.8: Window 1.6 Anchors
The anchor length is set to 350 mm. The horizontal spacing to edges of the base plate is 40 mm.
The washer thickness is increased to 50 mm.
12 Examples
© Dlubal Software GmbH 2015
90
12
12.1.2.7 Shear Transfer
Since the shear force should be transferred only by friction, the Anchors check box is unselected.
Figure 12.9: Window 1.7 Shear Transfer
The input data is complete now.
12.1.3 Calculation
The determination of designs starts by clicking the [Calculation] button.
Figure 12.10: Calculation dialog box
12 Examples
© Dlubal Software GmbH 2015
91
12
12.1.4 Designs
The 3.1 Designs - Summary window provides an overview of the relevant designs.
12.1.4.1 Part of Joint in Compression
Figure 12.11: Window 3.1 Designs - Summary, Part of the joint in compression
Stress concentration factor
𝑎1 = 𝑏1 = min
⎧
{
⎨
{
⎩
ℎ 𝑝 + 2 (𝑎 − ℎ 𝑝) = 210 + 2 (1,000 − 210) = 1,790 mm
3ℎ 𝑝 = 3 ⋅ 210 = 630 mm
ℎ 𝑝 + ℎfooting = 210 + 400 = 610 mm
𝑘 𝑗 = √
𝑎1 𝑏1
ℎ 𝑝 𝑏 𝑝
= √
610 ⋅ 610
220 ⋅ 210
= 2.82
Bearing strength of the foundation
𝑓 𝑗 ,𝑑 = 𝛽 𝑗 𝑘 𝑗 𝑓 𝑐 𝑑 =
2
3
⋅ 2.82 ⋅ 1.13 = 2.13 kN/cm2
[1] , Equation (6.6)
12 Examples
© Dlubal Software GmbH 2015
92
12
Base plate overlap
𝑐 = 𝑡 𝑝√
𝑓 𝑦,𝑘
3𝑓 𝑗 ,𝑑 𝛾 𝑀 0
= 4.0√
23.5
3 ⋅ 2.13 ⋅ 1.0
= 7.67 cm [1] , Equation (6.5)
𝑐1 = 7.67 cm ≥ 𝑢 = 1.0 cm
𝑐2 = 7.67 cm ≤
ℎ 𝑐 − 2𝑡 𝑓 ,𝑐
2
=
19.0 − 2 ⋅ 1.0
2
= 8.5 cm
𝑐3 = 7.67 cm ≥ 𝑢 = 1.0 cm
𝑏 𝑒𝑓 𝑓 = 𝑢 + 𝑡 𝑓 ,𝑐 + 𝑐2 = 1.0 + 1.0 + 7.67 = 9.67 cm
𝑙 𝑒𝑓 𝑓 = 𝑏 𝑐 + 2𝑐3 = 20.0 + 2 ⋅ 1.0 = 22.0 cm
𝐴 𝑐,1 = 𝑏 𝑒𝑓 𝑓 𝑙 𝑒𝑓 𝑓 = 9.67 ⋅ 22.0 = 212.74 cm2
𝐴 𝑐,2 = (𝑡 𝑤,𝑐 + 2𝑐2) (ℎ 𝑐 − 2𝑡 𝑓 ,𝑐 − 2𝑐2)
= (0.65 + 2 ⋅ 7.67) (19.0 − 2 ⋅ 1.0 − 2 ⋅ 7.67) = 26.54 cm2
𝐴 𝑐,3 = 𝑏 𝑒𝑓 𝑓 𝑙 𝑒𝑓 𝑓 = 9.67 ⋅ 22.0 = 212.74 cm2
𝐴 𝑐,0 = 𝐴 𝑐,1 + 𝐴 𝑐,2 + 𝐴 𝑐,3 = 452.02 cm2
The total design compression resistance results from the summed up resistances of the T-stub:
𝐹 𝑐,𝑅 𝑑= 𝐴 𝑐,0 𝑓 𝑗 ,𝑑 = 452.02 ⋅ 2.13 = 962.80 kN [1] , Equation (6.4)
Check:
𝑁 𝑐,𝐸 𝑑
𝐹 𝑐,𝑅 𝑑
=
580.00
962.80
= 0.60 ≤ 1.00 [1] , Clause 6.2.8.2
12 Examples
© Dlubal Software GmbH 2015
93
12
12.1.4.2 Shear Resistance of Joint
Figure 12.12: Window 3.1 Designs - Summary, Shear resistance of the joint
Friction between base plate and grout
𝐹 𝑓 ,𝑅 𝑑= 𝐶 𝑓 ,𝑑 𝑁 𝑐,𝐸 𝑑 [1] , Equation (6.1)
𝐶 𝑓 ,𝑑 = 0.20
𝑁 𝑐,𝐸 𝑑= −580 kN
𝐹 𝑓 ,𝑅 𝑑= 0.20 ⋅ | − 580 kN| = 116 kN
Check:
𝑉 𝐸 𝑑
𝐹 𝑓 ,𝑅 𝑑
=
100
116
= 0.86 ≤ 1.00
The shear force can be removed by the friction resistance. It is not necessary to implement any
other measures, for example dowels.
12 Examples
© Dlubal Software GmbH 2015
94
12
12.1.4.3 Welds
The welds are designed for the column flanges and the column web.
Column flange
Figure 12.13: Window 3.1 Designs - Summary, Column flanges to base plate
𝜎⊥ = 𝜏⊥ =
𝑁 𝑑
√
2𝐴 𝑤
≤ 0.9
𝑓 𝑢
𝛾 𝑀 2
[1] , Equation (4.1)
𝜎⊥ = 𝜏⊥ =
580.00
√
2 ⋅ 39.32
≤ 0.9
36.00
1.25
𝜎⊥ = 𝜏⊥ = 10.43 kN/cm2
≤ 25.90 kN/cm2
Check:
10.43
25.90
= 0.40 ≤ 1.00
𝜎 𝑤 = √ 𝜎2
⊥
+ 3 (𝜏 2
⊥
+ 𝜏 2
∥
) ≤
𝑓 𝑢
𝛽 𝑤 𝛾 𝑀 2
[1] , Equation (4.1)
𝜎 𝑤 = √10.432
+ 3 (10.432
+ 02
) ≤
36.00
0.8 ⋅ 1.25
𝜎 𝑤 = 20.86 kN/cm2
≤ 36.00 kN/cm2
Check:
20.86
36.00
= 0.58 ≤ 1.00
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual
Joints manual

More Related Content

What's hot

Ibm info sphere datastage data flow and job design
Ibm info sphere datastage data flow and job designIbm info sphere datastage data flow and job design
Ibm info sphere datastage data flow and job designdivjeev
 
User manual
User manualUser manual
User manualhmmhmm
 
Math for programmers
Math for programmersMath for programmers
Math for programmersmustafa sarac
 
Tcxd 300 manual_02.10.10
Tcxd 300 manual_02.10.10Tcxd 300 manual_02.10.10
Tcxd 300 manual_02.10.10jftorresco
 
GUIA REFERENCIA EZSTEER PARA EZ250
GUIA REFERENCIA EZSTEER PARA EZ250GUIA REFERENCIA EZSTEER PARA EZ250
GUIA REFERENCIA EZSTEER PARA EZ250Pablo Cea Campos
 
0802 python-tutorial
0802 python-tutorial0802 python-tutorial
0802 python-tutorialZahid Hasan
 
User manual PSPP
User manual PSPPUser manual PSPP
User manual PSPPVlad Millea
 
1660 S M Tec R5
1660 S M  Tec  R51660 S M  Tec  R5
1660 S M Tec R5Fxx
 
Open edX Building and Running a Course
Open edX Building and Running a CourseOpen edX Building and Running a Course
Open edX Building and Running a CourseAmish Gandhi
 

What's hot (17)

Ibm info sphere datastage data flow and job design
Ibm info sphere datastage data flow and job designIbm info sphere datastage data flow and job design
Ibm info sphere datastage data flow and job design
 
Sg246776
Sg246776Sg246776
Sg246776
 
Javanotes6 linked
Javanotes6 linkedJavanotes6 linked
Javanotes6 linked
 
10.1.1.652.4894
10.1.1.652.489410.1.1.652.4894
10.1.1.652.4894
 
PSA user manual
PSA user manualPSA user manual
PSA user manual
 
User manual
User manualUser manual
User manual
 
User manual
User manualUser manual
User manual
 
Networkx 0.99
Networkx 0.99Networkx 0.99
Networkx 0.99
 
User manual
User manualUser manual
User manual
 
Math for programmers
Math for programmersMath for programmers
Math for programmers
 
Tcxd 300 manual_02.10.10
Tcxd 300 manual_02.10.10Tcxd 300 manual_02.10.10
Tcxd 300 manual_02.10.10
 
GUIA REFERENCIA EZSTEER PARA EZ250
GUIA REFERENCIA EZSTEER PARA EZ250GUIA REFERENCIA EZSTEER PARA EZ250
GUIA REFERENCIA EZSTEER PARA EZ250
 
0802 python-tutorial
0802 python-tutorial0802 python-tutorial
0802 python-tutorial
 
Tutorial edit
Tutorial editTutorial edit
Tutorial edit
 
User manual PSPP
User manual PSPPUser manual PSPP
User manual PSPP
 
1660 S M Tec R5
1660 S M  Tec  R51660 S M  Tec  R5
1660 S M Tec R5
 
Open edX Building and Running a Course
Open edX Building and Running a CourseOpen edX Building and Running a Course
Open edX Building and Running a Course
 

Similar to Joints manual

Python_Programming_and_Numerical_Methods_A_Guide_for_Engineers_and.pdf
Python_Programming_and_Numerical_Methods_A_Guide_for_Engineers_and.pdfPython_Programming_and_Numerical_Methods_A_Guide_for_Engineers_and.pdf
Python_Programming_and_Numerical_Methods_A_Guide_for_Engineers_and.pdfjankoabel2022
 
Operations manual for_owners_and_managers_multi-unit_residential_buildings
Operations manual for_owners_and_managers_multi-unit_residential_buildingsOperations manual for_owners_and_managers_multi-unit_residential_buildings
Operations manual for_owners_and_managers_multi-unit_residential_buildingsSherry Schluessel
 
Team Omni L2 Requirements Revised
Team Omni L2 Requirements RevisedTeam Omni L2 Requirements Revised
Team Omni L2 Requirements RevisedAndrew Daws
 
Data Visualization with RRob Kabacoff2018-09-032
Data Visualization with RRob Kabacoff2018-09-032Data Visualization with RRob Kabacoff2018-09-032
Data Visualization with RRob Kabacoff2018-09-032OllieShoresna
 
ASME-Y14.5-2018-Dimensioning-and-Tolerancing - Copy.doc
ASME-Y14.5-2018-Dimensioning-and-Tolerancing - Copy.docASME-Y14.5-2018-Dimensioning-and-Tolerancing - Copy.doc
ASME-Y14.5-2018-Dimensioning-and-Tolerancing - Copy.docvishwanathvh
 
KTA, Pinjaman Tanpa Jaminan, Dana Pinjaman Tanpa Jaminan
KTA, Pinjaman Tanpa Jaminan, Dana Pinjaman Tanpa JaminanKTA, Pinjaman Tanpa Jaminan, Dana Pinjaman Tanpa Jaminan
KTA, Pinjaman Tanpa Jaminan, Dana Pinjaman Tanpa JaminanPinjamanTanpaJaminan
 
Manual for the design of pipe systems and pumps
Manual for the design of pipe systems and pumpsManual for the design of pipe systems and pumps
Manual for the design of pipe systems and pumpsSandro Marques Solidario
 

Similar to Joints manual (20)

Python_Programming_and_Numerical_Methods_A_Guide_for_Engineers_and.pdf
Python_Programming_and_Numerical_Methods_A_Guide_for_Engineers_and.pdfPython_Programming_and_Numerical_Methods_A_Guide_for_Engineers_and.pdf
Python_Programming_and_Numerical_Methods_A_Guide_for_Engineers_and.pdf
 
St3300655 lw
St3300655 lwSt3300655 lw
St3300655 lw
 
Pentest standard
Pentest standardPentest standard
Pentest standard
 
100384784c
100384784c100384784c
100384784c
 
Operations manual for_owners_and_managers_multi-unit_residential_buildings
Operations manual for_owners_and_managers_multi-unit_residential_buildingsOperations manual for_owners_and_managers_multi-unit_residential_buildings
Operations manual for_owners_and_managers_multi-unit_residential_buildings
 
Team Omni L2 Requirements Revised
Team Omni L2 Requirements RevisedTeam Omni L2 Requirements Revised
Team Omni L2 Requirements Revised
 
Data Visualization with RRob Kabacoff2018-09-032
Data Visualization with RRob Kabacoff2018-09-032Data Visualization with RRob Kabacoff2018-09-032
Data Visualization with RRob Kabacoff2018-09-032
 
Offshore structures
Offshore structuresOffshore structures
Offshore structures
 
ASME-Y14.5-2018-Dimensioning-and-Tolerancing - Copy.doc
ASME-Y14.5-2018-Dimensioning-and-Tolerancing - Copy.docASME-Y14.5-2018-Dimensioning-and-Tolerancing - Copy.doc
ASME-Y14.5-2018-Dimensioning-and-Tolerancing - Copy.doc
 
Graduation Report
Graduation ReportGraduation Report
Graduation Report
 
Ns doc
Ns docNs doc
Ns doc
 
KTA, Pinjaman Tanpa Jaminan, Dana Pinjaman Tanpa Jaminan
KTA, Pinjaman Tanpa Jaminan, Dana Pinjaman Tanpa JaminanKTA, Pinjaman Tanpa Jaminan, Dana Pinjaman Tanpa Jaminan
KTA, Pinjaman Tanpa Jaminan, Dana Pinjaman Tanpa Jaminan
 
49529487 abis-interface
49529487 abis-interface49529487 abis-interface
49529487 abis-interface
 
Latex2e
Latex2eLatex2e
Latex2e
 
Fraser_William
Fraser_WilliamFraser_William
Fraser_William
 
test6
test6test6
test6
 
Manual for the design of pipe systems and pumps
Manual for the design of pipe systems and pumpsManual for the design of pipe systems and pumps
Manual for the design of pipe systems and pumps
 
CDP FINAL REPORT
CDP FINAL REPORTCDP FINAL REPORT
CDP FINAL REPORT
 
R intro
R introR intro
R intro
 
AuthorCopy
AuthorCopyAuthorCopy
AuthorCopy
 

Recently uploaded

Current Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLCurrent Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLDeelipZope
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSCAESB
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineeringmalavadedarshan25
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZTE
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAbhinavSharma374939
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).pptssuser5c9d4b1
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 

Recently uploaded (20)

Current Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLCurrent Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCL
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineering
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog Converter
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxExploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
 

Joints manual

  • 1. Version June 2015 Add-on Module JOINTS Design of Connections in Steel and Timber Structures Program Description All rights, including those of translations, are reserved. No portion of this book may be reproduced – mechanically, elec- tronically, or by any other means, including photocopying – with- out written permission of DLUBAL SOFTWARE GMBH. © Dlubal Software GmbH 2015 Am Zellweg 2 D-93464 Tiefenbach Germany Tel.: +49 9673 9203-0 Fax: +49 9673 9203-51 E-mail: info@dlubal.com Web: www.dlubal.com
  • 2. Contents © Dlubal Software GmbH 2015 1 Contents Contents Page 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 JOINTS Add-on Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 Using the Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3 Opening JOINTS Add-on Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. General Input Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.3 Loads and Internal Forces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.3.1 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.3.2 Internal Forces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.4 National Annex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3. Steel - Column Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 3.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.4 Footing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.5 Base Plate and Welds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.6 Anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 3.7 Shear Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.8 Stiffeners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4. Steel - Tower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 4.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 4.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 4.4 Geometry 1 / Geometry 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 4.5 Geometry, Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 4.6 Diagonal 1,1 connection / Diagonal 1,2 connection . . . . . . . . . . . . . . 39 4.7 Definition of Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 5. Steel - DSTV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 5.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 5.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 5.4 Connection Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 6. Timber - Steel to Timber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 6.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 6.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 6.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 6.4 Load Duration and Service Class. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 6.5 Geometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 6.6 Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 7. Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 8. Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 8.1 Geometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 8.2 Designs - Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 8.3 Design by Load Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 8.4 Design by Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
  • 3. Contents © Dlubal Software GmbH 2015 2 8.5 Design - Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 8.6 Graphic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 8.7 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 9. Results Evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73 9.1 Graphic of Connection in JOINTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 9.2 Graphic of Connection in RSTAB Model . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 10. Printout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77 10.1 Printout Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 10.2 Graphic Printout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 10.2.1 JOINTS Graphic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 10.2.2 RSTAB Graphic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 11. General Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 11.1 Design Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 11.2 Units and Decimal Places . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 11.3 Data Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 12. Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 12.1 Steel - Column Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 12.1.1 System and Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 12.1.2 Entry in JOINTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 12.1.2.1 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 12.1.2.2 Nodes and Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 12.1.2.3 Internal forces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 12.1.2.4 Footing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 12.1.2.5 Base Plate and Welds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 12.1.2.6 Anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 12.1.2.7 Shear Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 12.1.3 Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 12.1.4 Designs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 12.1.4.1 Part of Joint in Compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 12.1.4.2 Shear Resistance of Joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 12.1.4.3 Welds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 12.2 Timber - Steel to Timber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 12.2.1 System and Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 12.2.2 Cross-Section Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 12.2.3 Designs - Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 12.2.3.1 Steel plate under bending, shear and axial force. . . . . . . . . . . . . . . . . . 99 12.2.3.2 Bearing resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 12.2.3.3 Load-carrying capacity per fastener . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 12.2.3.4 Load-carrying capacity per shear plane per dowel. . . . . . . . . . . . . . 102 12.2.3.5 Block shear failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 12.2.3.6 Effective number of dowels neff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 12.2.3.7 Transversal tension resistance of inclined forces . . . . . . . . . . . . . . . . 108 12.2.3.8 Transversal tension resistance due to moment . . . . . . . . . . . . . . . . . 109 12.2.3.9 Shear in net cross-section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 12.2.3.10 Minimum spacings between fasteners . . . . . . . . . . . . . . . . . . . . . . . . . 113 A. Literature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 B. Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
  • 4. 1 Introduction © Dlubal Software GmbH 2015 3 1 1 Introduction 1.1 JOINTS Add-on Module With the introduction of Eurocodes, the design of joints becomes more and more important. The European standard EN 1993-1-8 [1] describes the designs of steel connections. The design of timber connections is specified in EN 1995-1-1 [2]. The JOINTS add-on module combines connection modules developed in the previous RSTAB program versions in a single user interface. Furthermore, the scope of functions for the joint design has been extended and adapted to comply with the current requirements. At present, JOINTS covers steel categories ColumnBase, Tower and DSTV as well as a timber category Steel to timber connections. JOINTS Steel - Column Base designs footings of hinged and restrained steel columns. The Hinged Column Footing category includes the following base plate joint types: • Simple column base • Tapered column base • Column base plate for rectangular hollow sections • Column base plate for circular hollow sections The Restrained Column Footing category includes the following layouts of I-sections: • Simple column base • Base plate with stiffeners in center of flanges • Base plate with stiffeners on both sides of column • Base plate with channel sections • Bucket footing JOINTS Steel - Tower designs nominally pinned joints with bolt connections of members used in lattice towers for the following cases: • Connection of diagonals without gusset plate 2D • Connection of diagonals without gusset plate 3D • Column joint with splices JOINTSSteel-DSTVdesignsmomentresistantandpinnedI-beamconnectionsinaccordancewith the German guideline “Typified Connections in Steel Building Constructions” [3]. The resistances are determined according to DIN EN 1993-1-8 [1]. The Moment Resistant Joints category includes the following layouts: • End plate without column (IH type) • Beam joint with end plate (IH type) • Single-sided beam with end plate (IH type) • Double-sided beam with end plates (IH type) • Purlin joint with splices (PM type)
  • 5. 1 Introduction © Dlubal Software GmbH 2015 4 1 The Simple Joints category includes the following layouts: • End plate (IS type), or end plate with notching (IK type) • Angle (IW type), or angle with notching (IK type) • Long angles (IG type) JOINTS Timber - Steel to Timber designs timber joints indirectly connected by means of steel plates. There are hinged, bending-resistant and semi-rigid dowel connections available for the following cases: • Single member • Continuous member with secondary members • Connection of multiple single members The results including dimensions are shown in tables and graphics. Using the design cases, you can analyze different design variants. Since the JOINTS add-on module is integrated in the graphical user interface of the main program RSTAB, all input data of the model as well as the internal forces are already available for design. Some modules allow you to consider also connection stiffnesses and eccentricities when deter- mining internal forces. You can visualize the results in the RSTAB work window and include them in the global printout report. We wish you enjoyment and success with JOINTS. Your DLUBAL Team
  • 6. 1 Introduction © Dlubal Software GmbH 2015 5 1 1.2 Using the Manual Topics like installation, graphical user interface, results evaluation, and printout are described in detail in the manual of the main program RSTAB. The present manual focuses on typical features of the JOINTS add-on module. The descriptions in this manual follow the sequence and structure of the module's input and result windows. Chapter 2 describes the input parameters that apply to all steel and timber connections. The following chapters describe specific input parameters of the individual connections modules. The final chapter includes design examples. In the text, the described buttons are given in square brackets, for example [New]. The buttons are also shown in the left margin. Expressions appearing in dialog boxes, windows, and menus are set in italics to clarify the explanation. At the end of the manual, you find the index. However, if you still cannot find what you are looking for, please use the search function on our blog website www.dlubal.com/blog/en where you can find a solution in the posts about our add-on modules for joint design. 1.3 Opening JOINTS Add-on Module RSTAB provides the following options to open the JOINTS add-on module. Menu To open the program from the RSTAB menu bar, click Add-on Modules → Connections → JOINTS. Figure 1.1: Menu: Add-on Modules → Connections → JOINTS
  • 7. 1 Introduction © Dlubal Software GmbH 2015 6 1 Navigator As an alternative, you can open the add-on module in the Data navigator by clicking Add-on Modules → JOINTS. Figure 1.2: Data navigator: Add-on Modules → JOINTS
  • 8. 2 General Input Data © Dlubal Software GmbH 2015 7 2 2 General Input Data This chapter describes the input parameters that apply to all categories of steel and timber con- nections. The following chapters describe specific input parameters of the individual connection modules. When you open the JOINTS add-on module, a new window appears. In this window, a navigator is displayed on the left. The upper part of the navigator lists design cases (see Chapter 11.1, page 80) with selected nodes, the lower part covers windows of a specific module. The input data is defined in several module windows. When you open JOINTS for the first time, the following parameters are imported automatically: • Load cases, load and result combinations, super combinations, and dynamic envelopes • Materials • Cross-sections • Internal forces (in background, if calculated) To select a window, click the corresponding entry in the navigator. To set the previous or next window, use the buttons shown on the left. For scrolling in windows, you can also use the function keys to select the next [F2] or previous [F3] window. Click [OK] to save the results. Thus, you exit JOINTS and return to the main program. To close the add-on module without saving the data, click [Cancel]. 2.1 General Data In the 1.1 General Data window, you can define the basic settings necessary for joint design. Use the filter functions to select a specific type of connection. Figure 2.1: Window 1.1 General Data
  • 9. 2 General Input Data © Dlubal Software GmbH 2015 8 2 Material Figure 2.2: Filter for steel and timber connections In the Material section, you can define whether a steel or a timber connection is to be designed. This setting specifies the selection options available in the other window sections. Joint Group Figure 2.3: Filter for joint groups of steel material Figure 2.4: Filter for joint groups of timber material This window section specifies the connection type. You can select the relevant joint group by using the drop-down list or by clicking the buttons with the joint icons. Joint Category Figure 2.5: Filter for joint categories of column footings Figure 2.6: Filter for joint categories of steel to timber connection Use the drop-down list or the buttons to select the relevant joint category. Joint Type Figure 2.7: Filter for joint types of hinged column footings
  • 10. 2 General Input Data © Dlubal Software GmbH 2015 9 2 Figure 2.8: Filter for joint types of dowels In this window section, you can specify the exact type of the joint. Also here, you can select the type using the drop-down list or the joint icon buttons. According to Standard / National Annex Figure 2.9: Standard and National Annex Steel connections are designed automatically according to EN 1993-1-8 [1], timber connections according to EN 1995-1-1 [2]. In the drop-down list to the right of the standard, you can select the National Annex and thus apply these parameters to designs. Use the [Edit] button to open a dialog box where you can check the parameters of the selected National Annex. This dialog box is described in Chapter 2.4 on page 16. Comment In this text box, you can enter user-defined notes, for example to describe the current joint.
  • 11. 2 General Input Data © Dlubal Software GmbH 2015 10 2 2.2 Nodes and Members In the second window, you can select nodes to be analyzed. In addition, you can define the para- meters of the members connected to the nodes. Figure 2.10: Window 1.2 Nodes and Members Definition Type You can select nodes using the Importfromstructuremodel option. Thus, the geometric parameters such as a number and parameters of the connected members are imported automatically from RSTAB. As an alternative, the joint can be Set manually. Joint on Nodes No. In this text box, you can directly enter the numbers of the nodes to be analyzed. Use the [Select] button to determine the nodes graphically in the RSTAB work window. Multiple selection of nodes is useful only if they have identical input parameters. If there are different design conditions, it is not possible to combine the nodes in this window. In such a case, you have to create a new design case: Click File → New Case in the menu or use the buttons and below the Parameters section (see next). If you select Set manually, the data import from RSTAB is blocked. The note User-defined appears in the corresponding text box. Then, you can enter the Parameters regardless of the model. Figure 2.11: Setting a joint manually
  • 12. 2 General Input Data © Dlubal Software GmbH 2015 11 2 Parameters In this window section, you can define the properties of the components connected to the nodes specified above. Figure 2.12: Parameters section with the [Select inactive members] button Construction Status In this column, you can set the status of members for design. The selection options depend on the joint group and the joint category selected in Window 1.1. Cross-Section Description For the nodes imported from RSTAB, the member cross-sections are preset. To change the cross-section, click the entry to activate the text box. To open the cross-section library, use the button in the text box (see Figure 2.10) or press [F7]. Figure 2.13: Cross-section library Chapter 4.3 of the RSTAB manual describes how to select cross-sections from the library. A modified cross-section is highlighted in blue.
  • 13. 2 General Input Data © Dlubal Software GmbH 2015 12 2 Material Description When importing a node from RSTAB, the cross-section materials are preset as well. To change the material, click the entry to activate the text box. To open the cross-section library, use the button in the text box (see Figure 2.10) or press [F7]. Figure 2.14: Material library Chapter 4.2 of the RSTAB manual describes how to select materials from the library. The buttons in the Parameters section have the following functions: Button Function Reset default values of the joint Delete node selected in the table above Transfer the selected node to a new design case Transfer all unsuitable nodes to a new design case Set connection type for all nodes of the design case Show or hide inactive members in the table Jump to the RSTAB work window to change the view Table 2.1: Buttons in the Parameters section
  • 14. 2 General Input Data © Dlubal Software GmbH 2015 13 2 The buttons and have an important function: If you want to design several nodes with different boundary conditions, such as a number of connected members or member cross-sections, these buttons allow for manual or automatic assignment to new design cases. You can define the parameters for each node in different design cases. Alternatively, you can also click File → New Case in the menu. The design cases including data related to a node are displayed at the top of the navigator. The 1.2 Nodes and Members window always displays the parameters of the nodes selected in the navigator list. To switch the design case, simply click the relevant entry in the list. Graphic Window The graphic window presents a scheme of the connections to be designed. It shows a dynamic partial view of the model. The node selected in the Parameters section is indicated by an arrow. The connected members are highlighted. Figure 2.15: Graphic with selection arrow You can control the graphic by the same mouse functions as in RSTAB in order to zoom, shift or rotate the view. The buttons next to the graphic have the following functions: Button Function Show view in the direction of the X-axis Show view in the opposite direction of the X-axis Show view in the direction of the Y-axis Show view in the direction of the Z-axis Display the isometric view Reset full view of the graphic Table 2.2: Buttons in graphic window
  • 15. 2 General Input Data © Dlubal Software GmbH 2015 14 2 2.3 Loads and Internal Forces The structure of Window 1.3 depends on the Definition Type that you have selected in the previous Window 1.2 (see Figure 2.10, page 10). The data entered in this window always refers to the design case selected in the navigator on the top left. To switch the design case, simply click the relevant entry in the list. 2.3.1 Loads If you select the Import from structure model definition type in Window 1.2, you have to define the load cases or load combinations including internal forces to be applied for the design in the 1.3 Loads window. Figure 2.16: Window 1.3 Loads Existing Load Cases and Combinations This section lists all load cases as well as load and result combinations created in RSTAB. JOINTS can also design super combinations and DYNAM cases. Use the button to transfer the selected entries to the Selected for Design list on the right. Alter- natively, you can double-click the entries. To transfer the entire list to the right, use the button. To transfer multiple entries of load cases, click the entries while pressing the [Ctrl] key, as common for Windows applications. Thus, you can transfer several load cases at the same time. Load cases marked in red, like LC 5 or LC 6 in Figure 2.16, cannot be designed: This happens when the load cases are defined without any load data or contain only imperfections. When transferring such a load case, a corresponding warning appears.
  • 16. 2 General Input Data © Dlubal Software GmbH 2015 15 2 At the end of the list, several filter options are available. They will help you to assign the en- tries sorted by load case, load combination, or action category. The buttons have the following functions: Select all cases in the list Invert selection of load cases Table 2.3: Buttons in the Existing Load Cases and Combinations section Selected for Design The column on the right lists the load cases as well as the load and result combinations selected for design. Use the button or double-click the entries to remove selected items from the list. Use the button to transfer the entire list to the left. For a multiple selection, press [Ctrl] and click the corresponding entries. 2.3.2 Internal Forces If you select the Set manually definition type in Window 1.2 (see Chapter 2.2, page 10), you have to enter the internal forces to be applied for the design in the 1.3 Internal Forces window. Figure 2.17: Window 1.3 Internal Forces LC The internal forces are managed in a single load case. When you open the window for the first time, LC 1 is preset. Use the button to create a new load case. The load cases allow you to specify different combinations of internal forces for the design.
  • 17. 2 General Input Data © Dlubal Software GmbH 2015 16 2 Member In this column, you can enter a member number in order to facilitate the assignment of internal forces. Force / Symbol Both columns display the types of internal forces applied. Value / Unit In this column, you can enter values of the internal forces. To adjust the units and decimal places of the internal forces, use the menu and click Settings → Units and Decimal Places (see Chapter 11.2, page 82). The buttons below the table have the following functions: Create a new load case for additional internal forces Delete the load case selected above Table 2.4: Buttons in the 1.3 Internal Forces window 2.4 National Annex In the upper-right part of the 1.1 General Data window, you can select the National Annex, the pa- rameters of which should be applied for design (see Figure 2.9 on page 9). Click [Edit] to check the parameters. The content of the dialog box depends on the material selected (steel or timber connections). Steel Joints Figure 2.18: National Annex Settings - EN 1993-1-8/NA:2010-12 dialog box
  • 18. 2 General Input Data © Dlubal Software GmbH 2015 17 2 Timber Joints Figure 2.19: National Annex Settings - EN 1995-1-1:2004/A1:2008 dialog box These dialog boxes display various factors of the National Annex, for example the material factor, modification factor, and shear factor. Generally, you cannot change the values as they are codified in the National Annexes. Click [New] to create a user-defined National Annex, where you can freely define the factors. Furthermore, the [Nat. Annex] button is available in all input windows. You can use this button to open the National Annex Settings dialog box as well. The buttons in the National Annex Settings dialog box have the following functions: Button Function Reset original settings of the program Import user-defined default settings Save modified settings as default Delete user-defined National Annex Table 2.5: Buttons in the National Annex Settings dialog box
  • 19. 3 Steel - Column Base © Dlubal Software GmbH 2015 18 3 3 Steel - Column Base This chapter describes the individual windows of the JOINTS Steel - Column Base module. The general input parameters are described in Chapter 2. The input windows of the add-on module appear as soon as you select the Steel material and the Column Base joint group. Figure 3.1: JOINTS Steel - Column Base add-on module The input data always refers to the design case set in the navigator on the top left. To switch the design case, simply click the relevant entry in the list. If the entries Footing, Base Plate and Welds, Anchors etc. are missing in the navigator, go to the 1.2 Nodes and Members window and check if the boundary conditions required for the input of the column footing are correct. For example, it may be necessary to deactivate the connected members (see Figure 3.8, page 23). The input windows of the JOINTS Steel - Column Base module consist of two parts: On the left, you find the input parameters of the footing component that are illustrated in graphics on the right (see Figure 3.9, page 24). The upper graphic shows a system sketch of the current parameter, the lower graphic shows a 3D visualization of the column footing model. Figure 3.2: 3D visualization of column footing The buttons below the 3D graphic are described in the following table.
  • 20. 3 Steel - Column Base © Dlubal Software GmbH 2015 19 3 Button Function Display or hide dimensions Display dimension values or symbols Show view in the direction of the X-axis Show view in the opposite direction of the X-axis Show view in the direction of the Y-axis Show view in the direction of the Z-axis Display the isometric view Reset full view of the graphic Display or hide the irrelevant parts of the window Table 3.1: Buttons of 3D graphic 3.1 General Data Figure 3.3: Window 1.1 General Data
  • 21. 3 Steel - Column Base © Dlubal Software GmbH 2015 20 3 Joint Category Figure 3.4: Joint category It is necessary to specify whether you want to design a Hinged or Restrained column footing. You can use the drop-down list or the buttons with the joint icons to select the category. Joint Type The selection options depend on the joint category. Figure 3.5: Joint Type section of the Hinged Column Footing category The Hinged Column Footing category covers the following layouts: Column base plate without stiffening Tapered column base Column base plate for rectangular hollow sections Column base plate for circular hollow sections Table 3.2: Joint types of hinged column footings
  • 22. 3 Steel - Column Base © Dlubal Software GmbH 2015 21 3 Figure 3.6: Joint Type section of the Restrained Column Footing category The Restrained Column Footing category covers the following layouts for I-sections: Base plate without stiffening Base plate with stiffeners in center of flanges Base plate with stiffeners on both sides of column Base plate with channel sections on both sides of column and web members Bucket footing Table 3.3: Joint types of restrained column footings
  • 23. 3 Steel - Column Base © Dlubal Software GmbH 2015 22 3 Additional Settings Figure 3.7: Additional Settings section If you select the Use the column material for other joint components check box, the material of the column cross-section is automatically used for the base plate, anchors and shear keys. In this case, you cannot define the materials separately. A plastic Force distribution in joint applies. Cast-in anchors are preset as the Anchorage type. The connection between the steel base plate and the foundation can be made of a Grout layer or an Anchoring template set in concrete. By selecting the Simplified Results check box, you can reduce the output data: The program cal- culates all nodes and load cases that are available for design. Then, JOINTS filters the results and displays the governing results in the 3.1 Design - Summary window (see Figure 3.3, page 67). Win- dows 3.2 to 3.4 with the individual designs of each node and load case are not displayed in this case. Since these results are not processed, the calculation is considerably faster.
  • 24. 3 Steel - Column Base © Dlubal Software GmbH 2015 23 3 3.2 Nodes and Members The selection of nodes and members is described in Chapter 2.2 on page 10. In the Parameters section, you can check the boundary conditions of the connected components. If there is an Invalid cross-section, you should adjust the cross-section to the joint type set in Window 1.1. If several members such as diagonals are connected to one column base node, you can set the sta- tus of irrelevant members to Inactive. Figure 3.8: Setting the Inactive status of the diagonal member 3.3 Loads The entry of loads or internal forces is described in Chapter 2.3 on page 14.
  • 25. 3 Steel - Column Base © Dlubal Software GmbH 2015 24 3 3.4 Footing In the 1.4 Footing window, you can specify the foundation parameters and define the position of the base plate. Figure 3.9: Window 1.4 Footing Footing Inthiswindowsection, youcandefinethematerialanddimensionsofthefoundation. Usethe but- ton to open the material library, where you can find the properties of various types of concrete. Grout Layer Here you can define the grout thickness, the characteristic grout strength, and the friction coeffi- cient of the grout layer between the base plate and the foundation. Anchoring Template If you have selected the cast-in anchors option in the 1.1 General Data window, you can define dimensions of the plate in this section. In addition, it is possible to set a welded connection of the anchoring template and base plate. Additional Parameters You can specify the parameters of the Eccentricity of base plate in order to arrange the base plate eccentrically on the footing. Moreover, you can determine if there is an Edge reinforcement and select the form of it. The Cracks in concrete check box specifies if the concrete in cracked state is considered for the cal- culation.
  • 26. 3 Steel - Column Base © Dlubal Software GmbH 2015 25 3 Restrained Column Footing - Bucket Footing If you have selected the Bucket footing joint type in the 1.1 General Data window (see Figure 3.6, page 21), the 1.4 Footing window is displayed as follows: Figure 3.10: Window 1.4 Footing for the Bucket footing joint type Click to open the material library where you can select the materials of the foundation. You can enter the dimensions of the foundation plate and the bucket in the individual text boxes.
  • 27. 3 Steel - Column Base © Dlubal Software GmbH 2015 26 3 3.5 Base Plate and Welds In the 1.5 Base Plate and Welds window, you can define the base plate parameters. Figure 3.11: Window 1.5 Base Plate and Welds Base Plate In this window section, you can specify the material and dimensions of the base plate. Click to open the material library where you can find the properties of various steel grades. Base Plate Welds Select the Allow transfer of compression by contact between the column and the base plate check box to reduce action effects on the weld; the design internal force must be a compression force in this case. Tension forces are transferred by the welds without exception. Welds of the column cross-section on the base plate are applied according to the sketch displayed in the upper right graphic. You can enter the parameters of Weld on flange and Weld on web. In the case of rectangular and circular hollow sections, you can define the Weld on column. During the calculation, the add-on module checks also the structural details. For example, if the weld thickness exceeds the base plate dimensions, the corresponding error message appears. Figure 3.12: Conflict in structural details
  • 28. 3 Steel - Column Base © Dlubal Software GmbH 2015 27 3 Restrained Column Footing - Bucket Footing If you have selected the Bucket footing joint type in the 1.1 General Data window (see Figure 3.6, page 21), the 1.5 Column window appears as follows: Figure 3.13: Window 1.5 Column for the Bucket footing joint type Select the Base plate is welded to the end of column check box if there is a column base plate. Then, you can enter the base plate and weld parameters as described above. The Bearing of inner flange check box has an impact on the calculation. If you select the check box, the program takes into account the elastic compression of the concrete. This affects the load introduction length. If necessary, you can adjust the preset value of the Friction coefficient 𝜇 for the tension resistance. Furthermore, you can specify an eccentric arrangement of the column in the foundation by enter- ing parameters for the Eccentricity of the column.
  • 29. 3 Steel - Column Base © Dlubal Software GmbH 2015 28 3 3.6 Anchors The 1.6 Anchors window determines the parameters of column base anchors. Figure 3.14: Window 1.6 Anchors Anchors The Number of anchors is currently preset with two anchors (hinged column footings) or four anchors (restrained column footings). You can define the Diameter and the strength Class of the anchors using the drop-down lists. There are three Types of anchors available. They affect the design resistance when anchors are pulled out under tensile stress. You can control the partial safety factors for the design by specifying the Bond conditions and the Installation safety. Depending on the anchor bolt layout, it is possible to consider the Reduction of the determined design resistance according to [1], Table 3.4, by the factor 𝛽A = 0.85 (see [1], 3.6.1(3)). Anchor Dimensions You can arrange the anchors on a base plate by using the Anchor length parameter and entering the Spacing to the edges of the base plate. Additional Settings In this window section, you can specify the shape, size and thickness of Washers and Anchor heads. The graphic on the right provides a dynamic visualization of the input parameters.
  • 30. 3 Steel - Column Base © Dlubal Software GmbH 2015 29 3 3.7 Shear Transfer In the 1.7 Shear Transfer window, you can enter shear key parameters. Figure 3.15: Window 1.7 Shear Transfer Shear Key There are three options available under Shear transferred by: Friction, Anchors, and Shear key. However, these options cannot be freely combined with each other. Select the corresponding check box to increase the shear failure resistance. The friction resistance is considered if there is a compressive force. It reduces the available shear force so that anchor or shear key does not have to absorb such a high shear. If you select a shear key, the text boxes of the section above become available and you can select a cross-section from the RSTAB model. Use the button to define a different cross-section. The button displays the section properties. Click to change the cross-section subsequently. In addition, you can use the button to define specific material for the shear key (provided that the Use the column material for other joint components check box has not been activated in the 1.1 General Data window). Therefore, the materials used for the column, base plate, and shear key do not have to be identical. You can also specify the length of the shear key in the corresponding text box. Shear Key Welds In this window section, you can enter the thickness of the circumferential weld that connects the shear key with the base plate.
  • 31. 3 Steel - Column Base © Dlubal Software GmbH 2015 30 3 3.8 Stiffeners The 1.8 Stiffeners window is available for the following joint types: Tapered column base Restrained column base plate with stiffeners in center of flanges Restrained column base plate with stiffeners on both sides of column Table 3.4: Joint types with stiffeners Figure 3.16: Window 1.8 Stiffeners Stiffeners In this window section, you can define the geometric parameters of the stiffeners. Click to define the material separately. The Use the column material for other joint components check box in the 1.1 General Data window must be unselected.
  • 32. 3 Steel - Column Base © Dlubal Software GmbH 2015 31 3 Trimming In the case of restrained column base plates with stiffeners, you can enter the length of the vertical and horizontal trimmings. Stiffener Welds In this section, you can define the thickness of stiffener welds according to the joint type. The indi- vidual parameters are illustrated in the 3D graphic on the right. Horizontal Stiffener Welds In the case of hinged column footings with stiffeners, you can use a horizontal stiffener. Select the check box to activate the text boxes where you can define the thickness and the weld of the stiffener in compliance with the sketch. Restrained Column Footing - Base Plate with Channel Sections (Stiffeners/Crossbars) If you have selected the Base plate with channel sections joint type in the 1.1 General Data window (see Figure 3.6, page 21), the 1.8 Stiffeners and Crossbars window appears as follows: Figure 3.17: Window 1.8 Stiffeners and Crossbars for the Base plate with channel sections joint type Inbothtabsofthiswindow, youcanselecttheCross-sectionofthechannelstiffenersection. Click to define a different cross-section. To change the section subsequently, click . Use the button to select the Material of the cross-section from the library. The Length and Gap between crossbars text boxes specify the geometric parameters.
  • 33. 4 Steel - Tower © Dlubal Software GmbH 2015 32 4 4 Steel - Tower This chapter describes the individual windows of the JOINTS Steel - Tower module. The general input parameters are described in Chapter 2. The input windows of the add-on module appear as soon as you select the Steel material and the Tower joint group. Figure 4.1: JOINTS Steel - Tower add-on module The input data always refers to the design case set in the navigator on the top left. To switch the design case, simply click the relevant entry in the list. If the entries Geometry 1, Diagonal 1,1 connection etc. are missing in the navigator, go to the 1.2 Nodes and Members window and check if the boundary conditions of the node are cor- rect. For example, it may be necessary to adjust the status of connected members (see Figure 4.9, page 36). The input windows of the JOINTS Steel - Tower add-on module consist of two parts: On the left, you find the input parameters of the tower component that are illustrated in graphics on the right (see Figure 4.10, page 37). The upper graphic shows a system sketch of the current parameter, the lower graphic shows a 3D visualization of the node. Figure 4.2: 3D visualization of node The buttons below the 3D graphic are described in Table 4.1 on page 19.
  • 34. 4 Steel - Tower © Dlubal Software GmbH 2015 33 4 4.1 General Data Figure 4.3: Window 1.1 General Data Joint Category Figure 4.4: Joint category JOINTS Steel - Tower covers only the Tower Structure Joints category. Joint Type Figure 4.5: Joint type
  • 35. 4 Steel - Tower © Dlubal Software GmbH 2015 34 4 You can select one of the following joint types: Uniplanar joint with diagonals on one column leg Spatial joint with diagonals on both column legs Butt strap joint with sheets Table 4.1: Tower - Joint types 1. Alignment / 2. Alignment Figure 4.6: 1. and 2. Alignment This section specifies the individual geometric form of a joint in Plane 1 and Plane 2 (for 3D con- nections). The letters indicate the number of members on the connection node and their function: Major chord, minor chord, one strut Major chord, minor chord, two struts Major chord, minor chord, three struts Table 4.2: Alignment Figure 4.7: K Alignment
  • 36. 4 Steel - Tower © Dlubal Software GmbH 2015 35 4 Additional Settings Figure 4.8: Additional Settings section The program uses the simplified Joint calculation hypothesis according to [1], Clause 3.10.3, that is applicable for single-leg bolted connection of angles subjected to tensile stress (see [1], Clause 2.7 (2)). You can select the Category of connection according to [1], Clause 3.4 using the drop-down list. There are the categories A to C available for bolted connections loaded in shear. • Category A: Shear/Hole bearing connections • Category B: Slip-resistant connections at serviceability limit state • Category C: Slip-resistant connections at ultimate limit state In the case of high-strength prestressed bolted connections (Category B or C), you can select also the Class of friction surface from the drop-down list. The classes with the corresponding friction coefficient 𝜇 are set in [1], Table 3.7.
  • 37. 4 Steel - Tower © Dlubal Software GmbH 2015 36 4 4.2 Nodes and Members The selection of nodes and members is described in Chapter 2.2 on page 10. In the Parameters section, you can check the boundary conditions of the connected components. If there is an Invalid cross-section, you should adjust the cross-section to the joint type and to the alignment defined in Window 1.1. Figure 4.9: Adjusting the construction status The columns Angle and Priority provide information about the connected members. The angles are based on the geometrical conditions of the RSTAB model. If you select the Set manu- ally definition type in Window 1.2, you can enter a user-defined angle of the connected members. The priority of struts determines the distribution of windows Diagonal 1,1 connection, Diagonal 1,2 connection etc. The number before the comma assigns the struts to Plane 1 ("1. Alignment") or to Plane 2 ("2. Alignment" - only for 3D connections). The number after the comma numbers the members within the respective plane. The order is not design-relevant. Example: Priority 1,2 means "Plane 1, Strut 2". You can define bolt parameters in the Diagonal 1,2 connection window. When you click in a row of the table, the selected member is highlighted in the graphic. 4.3 Loads The input of loads and internal forces is described in Chapter 2.3 on page 14.
  • 38. 4 Steel - Tower © Dlubal Software GmbH 2015 37 4 4.4 Geometry 1 / Geometry 2 The Geometry window comprises the geometrical boundary conditions of the member on a con- nection node. There are two separate windows for both planes: The Geometry 1 window refers to Plane 1 ("1. Alignment"), the Geometry 2 window refers to Plane 2 ("2. Alignment" - only for 3D connections). Figure 4.10: Geometry 1 window Diagonals Orientation The arrangement of diagonals on a node is preset during the data transfer from the RSTAB model (see Figure 4.9, page 36). Text boxes of this window section are locked. If you define the geometry and the internal forces manually, you can enter a user-defined arrange- ment and orientation of diagonals as well (see figure above). The check boxes and the list entries describe the connected leg and its position. Joint Geometry Joint eccentricity describes the eccentricity of diagonals. It is based on the central axis intersection of the cross-section. As shown in the system sketch, positive values move the connection in the direction of the loose column leg, negative values in the direction of the corner angle. The local Diagonal offset in the direction of the longitudinal member is automatically updated in the text boxes below. The graphic on the right provides a dynamic visualization of the geometric parameters.
  • 39. 4 Steel - Tower © Dlubal Software GmbH 2015 38 4 4.5 Geometry, Plates If you have selected the Towers - Splices joint type in the 1.1 General Data window (see Figure 4.5, page 33), the Geometry, Plates window appears. Figure 4.11: Geometry, Plates window for the Towers - Splices joint type Joint Geometry In this window section, you can define the Joint gap size of a butt strap joint between the cross-sec- tions. Concerning the splices arrangement, you can select the External plates and/or Internal plates. The system sketch on the right illustrates the position of the plates. If you select the Dimensions of plates are calculated from the bolt spacing check box, the text boxes for entering length and width of plates below the check box are locked. You can select the Material of plates from the drop-down list or from the material library using the button. In the case of different cross-sections, it is possible to Insert pads to external or internal plates in order to settle the thickness differences. External/Internal Plates - Plane 1/2 In these text boxes, you can define the Thickness, Length and Width of external or internal plates. Plane 1 and Plane 2 refer to both angle legs. If you select the Dimensions of plates are calculated from the bolt spacing check box in the section above, you can enter only the thickness. During the calculation, the add-on module checks also the structural details. For example, if the splice dimensions are too small for the bolts, a corresponding error message appears.
  • 40. 4 Steel - Tower © Dlubal Software GmbH 2015 39 4 4.6 Diagonal 1,1 connection / Diagonal 1,2 connection In the Diagonal X,Y connection windows, you can define parameters of diagonals. There is a separate window for each plane and member. For example, the Diagonal 1,1 connection window refers to Plane 1 ("1. Alignment") and Strut 1, the Diagonal 1,2 connection window refers to Plane 1 and Strut 2. The Diagonal 2,1 connection window specifies the parameters of Strut 1 in Plane 2. Figure 4.12: Diagonal 1,1 connection window Bolts You can select the Class and Diameter of bolts from the relevant drop-down list. Each connection requires a similar type of bolts. In the text boxes, you can define the Hole diameter, Number of rows (currently only one row), Number of bolts in a row as well as the Distance from edges and between the bolts. The system sketch on the right illustrates the individual parameters. Welds This section includes the weld parameters of gusset plates. Since this connection type is not implemented yet, the text boxes are locked.
  • 41. 4 Steel - Tower © Dlubal Software GmbH 2015 40 4 4.7 Definition of Fasteners If you have selected the Towers - Splices joint type in the 1.1 General Data window (see Figure 4.5, page 33), you can define bolt parameters in the Definition of Fasteners window. Figure 4.13: Definition of Fasteners window Bolts You can select the Class and Diameter of bolts from the relevant drop-down list. Each connection requires a similar type of bolts. Both check boxes specify a position of the Shear plane and a bolt type (black bolts or Fit bolts). You can enter the Hole diameter separately. Dimensions in Plane 1 / 2 There is an individual section for each angle plane. You can define the Number of rows (currently only one row), Number of bolts in a row as well as the Distance from edges and between the bolts in the corresponding text box. The system sketch on the right illustrates the individual parameters.
  • 42. 5 Steel - DSTV © Dlubal Software GmbH 2015 41 5 5 Steel - DSTV This chapter describes the individual windows of the JOINTS Steel - DSTV module. The general input parameters are described in Chapter 2. The input windows of the add-on module appear as soon as you select the Steel material and the Typified joints - DSTV joint group. Figure 5.1: JOINTS Steel - DSTV add-on module The input data always refers to the design case set in the navigator on the top left. To switch the design case, simply click the relevant entry in the list. If the Connection Type entry is missing in the navigator, go to the 1.2 Nodes and Members window and check if the boundary conditions of the connection entry are correct. For example, it may be necessary to deactivate the connected members (see Figure 5.7, page 44). 5.1 General Data Figure 5.2: Window 1.1 General Data
  • 43. 5 Steel - DSTV © Dlubal Software GmbH 2015 42 5 Joint Category Figure 5.3: Joint category In this window section, you can specify whether you want to design Moment Resistant Joints or Simple Joints. You can use the drop-down list or the buttons with the joint icons to select the category. Joint Type The selection options depend on the joint category. Figure 5.4: Joint Type section of the Moment Resistant Joints category The Moment Resistant Joints category covers the following joint layouts: End plate without column Beam joint Single-sided beam Double-sided beam Purlin joint Table 5.1: Joint types of moment resistant joints
  • 44. 5 Steel - DSTV © Dlubal Software GmbH 2015 43 5 Figure 5.5: Joint Type section of the Simple joints category The Simple Joints category covers the following joint layouts: End plate Angle Long angle Table 5.2: Joint types of simple joints Additional Settings Figure 5.6: Additional Settings section The Export hinge and eccentricity automatically check box provides the option to consider the en- tered stiffnesses and eccentricities of the typified joints when determining the internal forces: When you start the [Calculation], the hinge stiffnesses Sj,ini and the eccentricities are transferred to RSTAB. Then, RSTAB calculates then the internal forces automatically with regard to the modified boundary conditions. The results are transferred back to JOINTS for further designs. This option is primarily applicable to moment resistant joints. Thus, you can consider the joint flexibility during the modeling process.
  • 45. 5 Steel - DSTV © Dlubal Software GmbH 2015 44 5 5.2 Nodes and Members The selection of nodes and members is described in Chapter 2.2 on page 10. In the Parameters section, you can check the boundary conditions of the connected components. If there is an Invalid cross-section, you should adjust the cross-section to the joint type set in Window 1.1. If several members such as beams, splices and diagonals are connected to a node, you can set the status of irrelevant members to Inactive. Figure 5.7: Setting the Inactive status of a beam In the case of the “Wrong angle between members” comment, you should check if the joint geometry corresponds to the requirements of typified joints. 5.3 Loads The entry of loads or internal forces is described in Chapter 2.3 on page 14.
  • 46. 5 Steel - DSTV © Dlubal Software GmbH 2015 45 5 5.4 Connection Types In the 1.4 Connection Types window, you can define the specific input parameters of the joint according to the DSTV type catalogue. Figure 5.8: Window 1.4 Connection Types The window consists of two parts: On the left, you find the joint parameters that are illustrated in the graphics on the right. The upper graphic shows a system sketch of the current parameter, the lower graphic shows a 3D visualization of the joint. The buttons below the 3D graphic are described in Table 5.1 on page 19. The upper left section displays the joint layouts according to DSTV guideline [3]. Each Type is characterized by a specific label and the respective Bolt size and Bolt class. Select the corresponding check box in the Used column to determine the connection type. The De- tails section below shows the parameters of these connections. The 3D graphic provides a dynamic view of the joint geometry. When you click the [Suggest the best type] button, JOINTS performs a quick layout design and displays the Utilization of each joint type in the last column (see figure above). It can help you choose a suitable joint for the design. Details In this window section, you can find all information about the selected joint such as cross-section and end plate geometry, bolts, welds, as well as resistances and stiffnesses.
  • 47. 5 Steel - DSTV © Dlubal Software GmbH 2015 46 5 Some categories provide additional modification options. Connection types IH 3 / IH 4 You can arrange the end plate extension above or below. This setting has an impact on the results, as the reverse moment may be the governing one. Figure 5.9: IH 3 joint with End plate extended Connection types IS / IW Simple joints of the IS type (joints with end plate) and IW type (joints with angles) can be combined with the IK type (notching). Figure 5.10: IW joint with Beam treatments of notching (IK type) In the other text boxes, you can specify the geometric parameters of the notching: Length, Height and Fillet corner radius. Figure 5.11: Selecting geometry parameters for notching For design purposes, the program analyzes the design resistance of the end plate or angle con- nections (IS/IW) and the resistance of the notching (IK). The lower of both values is the governing one.
  • 48. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 47 6 6 Timber - Steel to Timber This chapter describes the individual windows of the JOINTS Timber - Steel to Timber module. The general input parameters are described in Chapter 2. The input windows of the add-on module appear as soon as you select the Timber material and the Steel to timber connection joint group. Figure 6.1: JOINTS Timber - Steel to Timber add-on module The input data always refers to the design case set in the navigator on the top left. To switch the design case, simply click the relevant entry in the list. If the entries Load Duration and Service Class and Geometry are missing in the navigator, go to the 1.2 Nodes and Members window and check if the boundary conditions of the node are correct and the load cases are available for the design. For example, it may be necessary to adjust the status of connected members (see Figure 6.9, page 36). 6.1 General Data Figure 6.2: Window 1.1 General Data
  • 49. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 48 6 Joint Category Figure 6.3: Joint category JOINTS Timber - Steel to Timber covers only the Dowels category at this time. Joint Type Figure 6.4: Joint type You can select one of the following joint types: Main member only Connection of a member to an existing component (or multiple members) at any angle With continuous member Connection of the maximum of six diagonals to a continuous beam (Main member and Continuous member) Without continuous member Free definition of nodes with the maximum of eight connected members Table 6.1: Dowels - joint types Cutting - Main Member Figure 6.5: Cutting - Main Member The member can be connected to the main member symmetrically or asymmetrically (see Fig- ure 6.6). Symmetrical connection at an angle of 45° Main member cut by connected member Main member cut at right angle with the member axis
  • 50. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 49 6 Table 6.2: Connection options - Main Member Figure 6.6: Symmetrical connection (left) cut by connected member (middle) and at the angle of 45° (right) Cutting - Connected Members Figure 6.7: Cutting - Connected Members Two web members can be connected by a symmetrical or continuous cutting. Symmetrical cutting Continuous cutting Table 6.3: Connection options - Connected Member Figure 6.8: Continuously connected member
  • 51. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 50 6 According to Standard / National Annex Figure 6.9: According to Standard / National Annex section The design-relevant factors are preset according to the Standard and the National Annex (see Figure 6.19, page 17). If you want to apply user-defined factors for designs, click the button to create a new National Annex. Then, you can adjust the factors individually in the National Annex Settings dialog box. Figure 6.10: National Annex Settings dialog box , Dowels tab The Dowels tab allows you to specify the user-defined minimum spacing between the dowels as well as the minimum spacing of dowel groups loaded by moment. For example, the adjustment is necessary for the connection system of BSB company, the approval of which is based on different values. The user-defined minimum spacings between dowel groups are reasonable for dowel circles of a frame joint, for instance. They are not clearly defined in the design standard. In the Other Settings tab, you can adjust the shear correction factors kcr, if necessary.
  • 52. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 51 6 Additional Settings Figure 6.11: Additional Settings section You can define the steel plate and dowel materials using the drop-down lists and the buttons. If you select the SFS intec dowel system WS-T check box, the materials are preset according to manufacturer approval. Spacing between dowel rings If you select the Check minimum spacing between dowels in dowel group loaded by moment check box, the program analyzes also the minimum spacing between the individual fastener groups during the calculation. This applies to both circular and rectangular joints. After the calculation, you find the design of all minimum spacings under "Design Details". Figure 6.12: Details of Design No. 6510: Minimum spacing check
  • 53. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 52 6 To check deformation of the whole connection, select Check contact of members after deformation. In the 1.5 Geometry window, you can define the distance between timber members using the parameter og. Figure 6.13: Check contact of members after deformation The design 6530 checks whether the total deformation of the connection is greater that the dis- tance og defined. If the design is not fulfilled, the members are in contact. These contact properties are not considered in the JOINTS add-on module by default. Therefore, you should take the appropriate measures if the design was not fulfilled. The Design of main member dowel group from the sum of connected member internal forces option checks whether the design is performed using the corresponding internal forces at a member end or the internal forces resulting from two or more connected members on a node. This option is not available for the Main member only joint type. Figure 6.14: Internal forces on member For internal forces in the figure above, the axial force of −238.62 kN and the shear force of −9.60 kN are used on the upper flange without the Sum of internal forces option. This option is useful when transferring the axial force of a connection directly to the support, for example. However, the resulting axial and shear force are used with the Sum of internal forces option in order to design the eaves node.
  • 54. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 53 6 6.2 Nodes and Members The selection of nodes and members is described in Chapter 2.2 on page 10. In the Parameters section, you can check the boundary conditions of the connected components. You can also change the Status here, if necessary. Figure 6.15: Window 1.2 Nodes and Members - Adjusting status of members The columns Angle and Priority provide information about connected members. The angles are based on the geometrical conditions of the RSTAB model. If you select the Set manu- ally definition type in Window 1.2, you can enter a user-defined angle of the connected members. When you click in a row of the table, the selected member is highlighted in the graphic. Eaves node connection This window is especially important for the entry of eaves node connection. If the upper chord should continue, as shown in the figure on the left, you have to define it as a main member (the Without continuous member joint type has to be previously selected in Window 1.1). Figure 6.16: Eaves node with continuous upper chord
  • 55. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 54 6 If there are more than two members connected to a node, you can define the Status by using one of the following options: • Main Member - controls all other members as well as cutting and the priority of it • Continuous Member - available only for With continuous member joint type • Connected Member - assigns a lower priority to the other member (struts, splices) • Inactive - excludes the member from design In the following example, more members than allowed are connected to a node. Also the angle of Member 26 is too small. The connection geometry is functional only if the status of Member 26 is set to Inactive. Figure 6.17: Functional connection geometry due to inactive member The following limits apply to definition of members and web members: • Minimum member length: 42 cm • Minimum angle between members: 15° For the Main member only joint type, it is theoretically possible to connect an infinite number of members to a node (see the following figure). This can be advantage if you want to analyze only one joint of complex connection geometry. You can freely select the inclination, perimeter and eccentricity of the Main member only joint type.
  • 56. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 55 6 Figure 6.18: Connection of multiple members using the Main member only joint type 6.3 Loads The entry of loads and internal forces is described in Chapter 2.3 on page 14.
  • 57. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 56 6 6.4 Load Duration and Service Class The humidity-dependent strength changes of the anisotropic construction material timber are determined by the Load Duration Class (LDC) and the Service Class (SECL). Figure 6.19: 1.4 Load Duration and Service Class window Loads The window lists all loads selected for design in the 1.3 Loads window. The combinations are displayed including the related load cases. Description Load case descriptions facilitate the classification. Load Type This column shows action types of load cases that you have defined in RSTAB. They are fundamental for presettings in the next column. Load Duration Class LDC For design purposes, you should assign the loads and their superpositions to a specific load duration class. The classification of the effects is defined in [2], Table 2.1. You can change the load duration class of load cases and result combinations using the drop-down list. The classification of load combinations and OR result combinations is automatically preset, taking into account the principal actions or the included load cases. The load duration class is important for determination of the modification factor 𝑘 𝑚 𝑜𝑑 that has an impact on strength properties of the material (see [2], Table 3.1). You can check the factor 𝑘 𝑚 𝑜𝑑 in the National Annex Settings dialog box and adjust it, if necessary (see Figure 6.19, page 17).
  • 58. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 57 6 Service Class (SECL) The service classes allow you to assign strength parameters with regard to the environmental conditions. The service classes are specified in [2], Clause 2.3.1.3, for example. All members are assigned to the same service class by default. To assign the objects to different service classes, select the Different check box. Then, click the [Edit] button to open the following dialog box. Figure 6.20: Assign Members to Corresponding Service Classes dialog box Here you can individually distribute the members in the service classes. The buttons next to the text boxes facilitate the assignment. They have the following functions: Button Function Select members graphically in RSTAB work window Assign all members to the service class Assign not yet listed members to the service class Table 6.4: Buttons in the Assign Members to Corresponding Service Classes dialog box
  • 59. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 58 6 6.5 Geometry In the 1.5 Geometry window, you can define the parameters of steel plates and dowels. Figure 6.21: Window 1.5 Geometry The window consists of two parts: On the left, you find the input parameters of a joint component that are illustrated in the graphics on the right. The upper graphic shows a system sketch of the current parameter, the lower graphic shows a 3D visualization of the node. The buttons below the 3D graphic are described in Table 6.1 on page 19. Steel Plates You can define steel plate properties in this window section. Please note the following: • You can define the maximum Number of five slotted sheets. • Thickness of steel plate must be between 5 mm and 40 mm (for SFS: 3 mm). • Distance from dowels to plate edge must be greater than 1.2 d (see [1], Table 3.4). • Generally, the Width of slot is the same as the thickness of the plate. If the connection was produced with tolerances, you can increase the thickness of plate by a maximum of 1 mm. When using the SFS intec systems, you should keep the limit value of 2 mm. This setting makes no difference for the design because there are only the geometry limitations requested. • You can design the plates also as side plates. For this, you need to design at least two slotted sheets. The modified slotted plate layouts are visualized in the dynamic graphic.
  • 60. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 59 6 In the case of using more than one slotted steel plate, there is often a problem when generating predominant failure modes according to [2], Clause 8.2.3, Figure 8.3. The predominant (govern- ing) failure mode of fasteners in the respective joint has to be compatible with any other mode. Therefore, the combination of failure modes (c), (f) and (j/l) with the other failure modes is not allowed. Figure 6.22: Failure modes according to [2], Figure 8.3 JOINTS always checks the bearing resistance in the inner and the outer section of a multishear connection. For sections on the outer plate edge, it checks the failure modes (f), (g) and (h) for both thick and thin steel plates. The modes according to [2], Formula (8.9) and (8.10) are identical in this case. In the middle part, the program analyzes the failure cases according to [2], Formula (8.12) and (8.13). Also here, there is a distinction between thick steel plates in modes (l), (m), and thin steel plates in modes (j), (k). Figure 6.23: Failure modes: green dashed line (f), (g) and (h); purple dashed line (l), (m) or (j), (k) JOINTS always determines the governing failure mode of each joint. If there is a thin sheet plate with the governing failure mode (j) on inner (purple) shear planes and the mode (g) on outer (green) shear planes, the calculation is not possible. However, if the mode (f) is the governing one, the calculation will be performed. Connection Geometry This window section describes the dowel parameters. You can enter the data for each member separately. Use the drop-down list or the buttons to display the individual member. • You can define the Pattern of the dowel group as a rectangle or as a circle. • The dowel Diameter can be set between 6 mm and 30 mm. If you have selected the SFS intec dowel system in Window 1.1, the diameter is set to 7 mm by default. • If you want to define the dowel length lower than the cross-section thickness (in the case of fire resistance, for example), you need to enter the Plug length. Thus, the dowel length is reduced automatically.
  • 61. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 60 6 Circular dowel pattern You can define several dowel circles. The Number of dowel circles is limited by the cross-section height. In the text boxes below, you can define the Number of dowels in circle. Figure 6.24: Defining number of dowel circles Rectangular dowel pattern In the case of rectangular dowel arrangement, you can define the Number of dowel columns in the 𝑥-direction and the Number of dowel rows in the 𝑧-direction. Figure 6.25: Defining number of dowel columns You can also select the Staggered rows option to improve the crack behavior of the joint. The Method of dowel group placement can be targeted to the minimum dowel spacing or to the minimum edge distance. In addition, there is the option of user-defined placements. The Orientation of dowel columns and rows includes the following options: • Basic - Orientation to the local member coordinate system • Rotated - Orientation to the global coordinate system • Slanting - Orientation to edges with staggered rows • User-defined - Free definition of inclination and strain If the Dowel group reinforced by screws is secured against cracks, it is not necessary to reduce the effective number of dowels. In that case, you have to specify the reinforcement parameters separately. If you use the reinforcement, JOINTS checks the tension failure of bolts according to [2], Clause 8.7.2.
  • 62. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 61 6 The Main member only joint type allows you to cut the member at any angle and apply the joint to a reinforced concrete wall, for example. Figure 6.26: Defining cutting angle For the connected web members of a truss, you can define Member eccentricity, which deter- mines the member contour geometrically. The local member coordinate system is displayed in the graphic. Figure 6.27: Defining member eccentricity Click the [Details] button below the section (see Figure 6.27) to open the Details - List of Dowels dialog box. In this dialog box, you can deactivate the individual dowels or adjust the dowel diameter. Figure 6.28: Details dialog box The figure above shows the unselected Activity of Dowel No. 1.
  • 63. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 62 6 6.6 Details In the Details dialog box, you can specify the other design settings. This dialog box is available in all windows of the add-on module under the [Details] button. Figure 6.29: Details dialog box Design Value Settings IfyouCreatedesignvaluebyeditingcharacteristicload-carryingcapacity 𝐹 𝑣,𝑅 𝑘, thedesignresistance is adapted to the semi-probabilistic safety concept using the factors 𝑘 𝑚 𝑜𝑑 and 𝛾 𝑀 . The design value of the load-carrying capacity per dowel and slotted sheet is then: 𝐹 𝑣,𝑅 𝑑= 𝑘 𝑚 𝑜𝑑 ⋅ 𝐹 𝑣,𝑅 𝑘 𝛾 𝑀 (6.1) Alternatively, you can Create design value by editing characteristic embedment strength 𝑓ℎ,𝑘 and characteristic fastener yield moment 𝑀 𝑦,𝑅 𝑘. The embedment strength and the yield moment are adjusted to the partial safety factor for timber or steel. Embedment strength of timber: 𝐹ℎu�,𝑑 = 𝑘 𝑚 𝑜𝑑 ⋅ 𝑓ℎu�,𝑘 𝛾 𝑀 (6.2) Yield moment of dowels: 𝑀 𝑦,𝑅 𝑑= 𝑀 𝑦,𝑅 𝑘 𝛾 𝑀 0 (6.3)
  • 64. 6 Timber - Steel to Timber © Dlubal Software GmbH 2015 63 6 Generation to Structural Model The eccentricities available due to geometric parameters of JOINTS connections can be used also for modeling. The Generate member eccentricity check box allows you to export the member data to RSTAB. However, no other structural model is created there. In fact, the eccentricity is transferred to RSTAB as a member property when you start the JOINTS calculation. Using the modified model, the program determines the internal forces for design. This option is possible for all members where you can define the eccentricity. In the case of deleted or modified eccentricity, this is taken into account as well. You can check the generated eccentricities in the Edit Member Eccentricities dialog box in RSTAB. The values are not editable. Figure 6.30: Generated member eccentricity in RSTAB Options If you select the Load capacity of single dowel check box, the minimum timber thickness is checked according to formula (NA.116). The ultimate limit state design is performed then according to formula (NA.115), which corresponds to the simplified design. If you check the failure criteria according to Johansen, this simplified design is not necessary. If you select the Reduction of timber tensile strength check box, the tensile strength of timber is reduced by 60 % in the bending and compression design according to [2], Clause 6.2.3. You can avoid this reduction if you prevent the connection from warping (for example by using a guide pin).
  • 65. 7 Calculation © Dlubal Software GmbH 2015 64 7 7 Calculation You can start the calculation in all input windows of the JOINTS add-on module using the [Calcula- tion] button. JOINTS searches for the results of the load cases, load combinations and result combinations to be designed. If these cannot be found, the program starts the RSTAB calculation to determine the design-relevant internal forces. If you have selected the direct input of the internal forces (see Chapter 2.3.2, page 15), the RSTAB results are not relevant for the design. You can also start the calculation in the RSTAB user interface: The To Calculate dialog box (menu Calculate → To Calculate) lists design cases of the add-on modules such as load cases and load combinations. Figure 7.1: To Calculate dialog box If the JOINTS design cases are missing in the Not Calculated section, select All or Add-on Modules in the drop-down list below the section. Use the button to transfer the selected JOINT cases to the list on the right. Click [OK] to start the calculation. To calculate a design case directly, use the drop-down list in the toolbar: Select the JOINTS design case and click [Show Results]. Figure 7.2: Direct calculation of a JOINTS case in RSTAB Subsequently, you can see the design process in a separate dialog box.
  • 66. 8 Results © Dlubal Software GmbH 2015 65 8 8 Results The 3.1 Design - Summary window is displayed immediately after the calculation. Figure 8.1: Result window with designs, design ratios and design details The result data always refers to the design case set in the navigator on the top left. To switch the design case, simply click the relevant entry in the list. The content of the result windows is adapted to the results of the different JOINTS modules. The sequence and the concept of the windows are the same. Window 2.1 shows an overview graphic including geometric parameters of the connection com- ponents. Result windows 3.1 to 3.3 display the designs sorted by different criteria. Window 3.4 lists the in- termediate values of the individual designs. Window 4.1 shows a graphic of the connection including all geometry details, which can be printed as well. Window 5.1 lists notes that are relevant for the design. You can select each window by clicking the corresponding entry in the navigator. To set the pre- vious or next window, use the buttons shown on the left. You can also use the function keys to select the next [F2] or previous [F3] window. Click [OK] to save the results. Thus, you exit the JOINTS add-on module and return to the main program. Chapter 8 - describes the different result windows one by one. The evaluation of and checking results is described in Chapter 9 - , page ?? ff.
  • 67. 8 Results © Dlubal Software GmbH 2015 66 8 8.1 Geometry This window lists all geometry parameters of the connection. Figure 8.2: Window 2.1 Geometry Click to display the list entries and to hide them, as common for Windows applications. The graphic shows the component selected in the list including the parameters. The buttons are described in Chapter 9 - on page 74.
  • 68. 8 Results © Dlubal Software GmbH 2015 67 8 8.2 Designs - Summary This window lists the maximum design ratios of all designed nodes. The internal force ratios of the governing load cases and combinations are sorted by design type. Figure 8.3: Window 3.1 Designs - Summary Governing Node This column displays the number of the node with the highest design ratio for the design type indicated in column E. Governing Load In this column, you find the numbers of the load cases or load combinations with the internal forces resulting in the maximum design ratio. Design Ratio Columns C and D display the design conditions according to EN 1993-1-8 [1] or EN 1995-1-1 [2]. The length of the colored bars represents the respective design ratio. Design According to Formula This column displays the individual designs according to [1] or [2]. Design numbers of the JOINTS Timber - Steel to Timber module are defined in Table 8.5 on page 99. Design Details In this window section, you can find the detailed information on the design parameters of the entry selected above.
  • 69. 8 Results © Dlubal Software GmbH 2015 68 8 8.3 Design by Load Case Theupperpartofthewindowliststhegoverningdesignssortedbyloadcaseandloadcombination. The lower part includes detailed information on the internal forces and design parameters of the load case selected above. Figure 8.4: Window 3.2 Design by Load Case Description This column provides the descriptions of the load cases and load combinations used for designs. Node No. This column displays the number of the node with the maximum design ratio of the designed actions. Design Columns C and D display the design conditions according to [1] or [2]. The length of the colored bars represents the respective design ratio. Design According to Formula This column lists the individual equations of the Standard that has been used for the designs.
  • 70. 8 Results © Dlubal Software GmbH 2015 69 8 8.4 Design by Node Figure 8.5: Window 3.3 Design by node This window displays the maximum design ratios of the designed nodes.
  • 71. 8 Results © Dlubal Software GmbH 2015 70 8 8.5 Design - Details Figure 8.6: Window 3.4 Design - Details This result window lists all individual designs including design ratios used for the connection. The section below provides detailed information on the design parameters selected above.
  • 72. 8 Results © Dlubal Software GmbH 2015 71 8 8.6 Graphic This window shows a graphic of the connection including all components. Figure 8.7: Window 4.1 Graphic The Components to Display section lists all components of the connection. You can display or hide the individual components using the corresponding check boxes. Click to display the subentries. In this way, you can also display the Dimensions and Outlines of the particular components. The graphic view is dynamic. The mouse functions known from RSTAB allow you to zoom, shift or rotate the view. The buttons are described in Chapter 9 - on page 74.
  • 73. 8 Results © Dlubal Software GmbH 2015 72 8 8.7 Notes Figure 8.8: Window 5.1 Notes The last result window displays the notes that are important for the joint design.
  • 74. 9 Results Evaluation © Dlubal Software GmbH 2015 73 9 9 Results Evaluation Windows 3.1 to 3.4 display the results sorted by various criteria. The buttons below facilitate the evaluation. Figure 9.1: Buttons for results evaluation in tables The buttons have the following functions: Button Description Function View Mode Jump to the RSTAB work window to change the view Exceeding Display only rows with a ratio greater than 1 (design not fulfilled) Color Bars Display or hide colored relation scales in the result windows Excel Export Export the table to MS Excel / OpenOffice → Chapter 11.3, page 83 Table 9.1: Buttons in result windows 3.1 to 3.4
  • 75. 9 Results Evaluation © Dlubal Software GmbH 2015 74 9 9.1 Graphic of Connection in JOINTS Each result window shows a dynamic graphic of the connection. It provides an overview and illustrates the parameters. Figure 9.2: Graphic of connection The buttons below the graphic have the following functions: Button Function Display or hide dimensions Display dimension values or symbols Show view in the direction of the X-axis Show view in the opposite direction of the X-axis Show view in the direction of the Y-axis Show view in the direction of the Z-axis Display the isometric view Reset full view of the graphic Display or hide the irrelevant parts Print the current 3D graphic Table 9.2: Graphic buttons in result windows Use the mouse functions to zoom, shift or rotate the view. These functions are described in Chapter 3.4.9 of the RSTAB manual. Use the [Show unselected parts transparent] button to display only the selected components including dimensions, for example anchors.
  • 76. 9 Results Evaluation © Dlubal Software GmbH 2015 75 9 Figure 9.3: Show Unselected Parts Transparently button Click to print the graphic.
  • 77. 9 Results Evaluation © Dlubal Software GmbH 2015 76 9 9.2 Graphic of Connection in RSTAB Model The graphic of the connection can be also displayed in the RSTAB model: Click [OK] to close the JOINTS module. Then, select the JOINTS load case in the RSTAB menu bar. The RSTAB work window displays the connections in 3D rendering. Figure 9.4: Displaying connections in RSTAB work window Similarly to the display of internal forces, the [Show Results] button displays or hides the module results. RSTAB does not provide a Results navigator for the JOINTS design cases. Furthermore, the RSTAB tables are not relevant for JOINTS. You can use the View Mode option (see RSTAB manual, Chapter 9.7.1) to filter the nodes of the con- nection. You can print the graphic of the connection directly or send it to the printout report (see Chap- ter 10.2, page 77).
  • 78. 10 Printout © Dlubal Software GmbH 2015 77 10 10 Printout 10.1 Printout Report Similarly to RSTAB, the program generates a printout report of the JOINTS results, to which you can add graphics and descriptions. The selection in the printout report determines what data from the connection module will be included in the printout. The printout report is described in the RSTAB manual. In particular, Chapter 10.1.3.5 Selecting Data of Add-on Modules describes how to select input and output data from add-on modules for the printout report. For complex structural systems with many design cases, it is recommended to split the data into several printout reports, thus allowing for a clearly-arranged printout. The parameters of input windows 1.4 to 1.8. are summarized in the 1.2.2 Geometry Details table of the printout report. Figure 10.1: Printout report including Table 1.2.2 Geometry Details 10.2 Graphic Printout You can print the graphics of the JOINTS add-on module as well as of the RSTAB work window. 10.2.1 JOINTS Graphic To print the graphic, use the [Print] button that is available in the 2.1 Geometry window and in the 4.1 Graphic window on the right below the graphic (see Figure 10.2, page 74). Click this button to open the following printout dialog box.
  • 79. 10 Printout © Dlubal Software GmbH 2015 78 10 Figure 10.2: Graphic Printout dialog box, General tab This dialog box is described in the RSTAB manual, Chapter 10.2. There you can find the description of the Options tab as well. If there are several printout reports available, you can select the number of the target report in the list. In order to add several graphics in the printout report consecutively, you should unselect the Show printout report on [OK] check box. Figure 10.3: Connection graphic in the printout report
  • 80. 10 Printout © Dlubal Software GmbH 2015 79 10 10.2.2 RSTAB Graphic In RSTAB, you can add every picture that is displayed in the work window to the printout report or send it directly to a printer. In this way, you can prepare the connections displayed in the RSTAB model for the printout as well. To print the currently displayed graphic of the connection, click File → Print Graphic in the menu or use the toolbar button shown on the left. Figure 10.4: Print Graphic button in RSTAB toolbar The Graphic Printout dialog box appears, as shown in Figure 10.2. You can move the graphic anywhere within the printout report by using the drag-and-drop func- tion. To adjust a graphic subsequently in the printout report, right-click the relevant entry in the printout report navigator. The Properties option in the shortcut menu opens the Graphic Printout dialog box, providing various options for adjustment. Figure 10.5: Graphic Printout dialog box , Options tab
  • 81. 11 General Functions © Dlubal Software GmbH 2015 80 11 11 General Functions This chapter describes useful menu functions as well as export options for the designs. 11.1 Design Cases Design cases allow you to group members for a design. In this way, you can combine connec- tion nodes with similar parameters or analyze members with particular design specifications (for example materials, internal forces). If the conditions of designed nodes are different in terms of the cross-sections, dimensions, number of bolts etc., you have to create a new design case. You cannot specify all entries in a single design case. In the 1.2 Nodes and Members window, you can click the [Transfer the node to a new case] button or the [Transfer unsuitable nodes to new case] button to quickly create new design cases (see Figure 11.10, page 10). Then you can define the node-specific parameters. The design cases are displayed in the navigator on the top left. To switch the design case, simply click the relevant list entry. To display JOINTS design cases, you can also click the relevant entry in the load case list in the menu toolbar of RSTAB. Create New Design Case To create a new design case, use the JOINTS menu and click File → New Case. The following dialog box appears: Figure 11.1: New JOINTS Case dialog box In this dialog box, enter a Number (that is still available) for the new design case. The corresponding description makes the selection from the load case list easier. Click [OK] to open the 1.1 General Data window in the JOINTS add-on module where you can enter the design data. Rename Design Case To change the description of a design case, use the JOINTS menu and click File → Rename Case. The following dialog box appears: Figure 11.2: Rename JOINTS Case dialog box In this dialog box, you can specify a different Description as well as a Number of the design case.
  • 82. 11 General Functions © Dlubal Software GmbH 2015 81 11 Copy Design Case To copy the input data of the current design case, use the JOINTS menu and click File → Copy Case. The following dialog box appears: Figure 11.3: Copy JOINTS Case dialog box Define the Number and, if necessary, a Description of the new case. Delete Design Case To delete design cases, use the JOINTS menu and click File → Delete Case. The following dialog box appears: Figure 11.4: Delete Case dialog box You can select a design case in the list of Available Cases. To delete the selected case, click [OK].
  • 83. 11 General Functions © Dlubal Software GmbH 2015 82 11 11.2 Units and Decimal Places Units and decimal places of RSTAB and add-on modules are managed in one dialog box. To open the corresponding dialog box, use the JOINTS menu and click Settings → Units and Decimal Places. The following dialog box appears which you already know from RSTAB. The JOINTS module is preset in the Program / Module list. Figure 11.5: Units and Decimal Places dialog box You can save the settings as a user-defined profile to reuse them in other models. These functions are described in Chapter 11.1.3 of the RSTAB manual. 11.3 Data Transfer You can use the input and output data of the JOINTS add-on module also in other programs. Clipboard To copy cells selected in the result windows to the Clipboard, use the keys [Ctrl]+[C]. Press [Ctrl]+[V] to insert the cells, for example in a word processing program. The headers of the table columns will not be transferred. Printout Report You can print the data of JOINTS into the global printout report (see Chapter 10.1, page 77) and export them subsequently. For this, click File → Export to RTF. This function is described in the RSTAB manual, Chapter 10.1.11.
  • 84. 11 General Functions © Dlubal Software GmbH 2015 83 11 Excel / OpenOffice JOINTS provides a function for directly exporting data to MS Excel, OpenOffice.org Calc, or to the CSV file format. To open the corresponding dialog box, click File → Export Tables. The following export dialog box appears. Figure 11.6: Export of Tables dialog box When you have selected the relevant options, you can start the export by clicking [OK]. Excel or OpenOffice will be started automatically, you do not need to open the programs first. Figure 11.7: Results in Excel
  • 85. 12 Examples © Dlubal Software GmbH 2015 84 12 12 Examples This chapter presents two examples of a joint design in the JOINTS add-on module. For more examples, see the verification examples on our website: www.dlubal.com/en/examples.aspx 12.1 Steel - Column Base A hinged column footing is analyzed according to EN 1993-1-8 [1] and EN 1992-1-1 [4]. The example was published in the book “Stahlbau nach EC3” [5], page 261. 12.1.1 System and Loads Figure 12.1: System and load according to [5] System Hinged internal column Column Cross-section HE A 200, Steel S 235 JR Depth hc 190 mm Width bc 200 mm Flange thickness tfc 10 mm Web thickness twc 6.5 mm Root fillet radius rc 18 mm Cross-sectional area Ac 53.8 cm3 Table 12.1: Column cross-section Base plate Thickness tp 40 mm Width bp 220 mm Depth hp 210 mm Extension u 10 mm Weld on flange af 4 mm Weld on web aw 4 mm Table 12.2: Base plate
  • 86. 12 Examples © Dlubal Software GmbH 2015 85 12 Loads Axial force NEd 580 kN Shear force VEd 100 kN Table 12.3: Loads 12.1.2 Entry in JOINTS 12.1.2.1 General Data First of all, a new model is created in RSTAB. Then, we can directly open the JOINTS add-on module. The following input data is defined in the 1.1 General Data window: Figure 12.2: JOINTS Window 1.1 General Data The design is performed according to Eurocode with DIN factors of the German National Annex. The example concerns the Column Base joint group, the Hinged Column Footing joint category and the Simple column base joint type.
  • 87. 12 Examples © Dlubal Software GmbH 2015 86 12 12.1.2.2 Nodes and Members The column cross-section and the material are defined in the 1.2 Nodes and Members window. Figure 12.3: Window 1.2 Nodes and Members The definition type is changed to Set manually. The cross-section HE-A 200 and the material Steel S 235 JR are selected from the libraries using the button. A query appears that should be confirmed by clicking [Yes]. Figure 12.4: RSTAB query
  • 88. 12 Examples © Dlubal Software GmbH 2015 87 12 12.1.2.3 Internal forces The loads are defined in the 1.3 Internal Forces window (compression force with negative sign). Figure 12.5: Window 1.3 Internal Forces 12.1.2.4 Footing The 1.4 Footing window specifies the footing parameters. Figure 12.6: Window 1.4 Footing The Concrete C20/25 class of concrete was selected in the library using the button.
  • 89. 12 Examples © Dlubal Software GmbH 2015 88 12 The grout thickness is set to 0.02 m. It is possible to apply the same value also for the characteristic grout strength. Foundation length and width are set to 1.0 m. Foundation depth can be reduced to 0.40 m: ℎ ≥ √𝐴 𝑐,1 − √𝐴 𝑐,0 𝐴 𝑐,0 = ℎ 𝑐 𝑏 𝑐 = 190 mm ⋅ 200 mm = 38,000 mm2 𝐴 𝑐,1 = min (1.0 ⋅ 1.0; 9𝐴 𝑐,0) = 342,000 mm2 ℎ ≥ 390 mm ⇒ selected: ℎ = 400 mm 12.1.2.5 Base Plate and Welds The base plate is made of STEEL S 235 JR. With the extension u = 10 mm, the dimensions are defined as follows: Figure 12.7: Window 1.5 Base Plate and Welds According to Table 12.2, the base plate thickness is set to 40 mm. Both thickness of weld on flange and weld on web are set to 4 mm.
  • 90. 12 Examples © Dlubal Software GmbH 2015 89 12 12.1.2.6 Anchors Since the example of [5] includes no information about anchors, the Straight ribbed rod anchors with diameter of M18 and 5.6 strength class were selected. Figure 12.8: Window 1.6 Anchors The anchor length is set to 350 mm. The horizontal spacing to edges of the base plate is 40 mm. The washer thickness is increased to 50 mm.
  • 91. 12 Examples © Dlubal Software GmbH 2015 90 12 12.1.2.7 Shear Transfer Since the shear force should be transferred only by friction, the Anchors check box is unselected. Figure 12.9: Window 1.7 Shear Transfer The input data is complete now. 12.1.3 Calculation The determination of designs starts by clicking the [Calculation] button. Figure 12.10: Calculation dialog box
  • 92. 12 Examples © Dlubal Software GmbH 2015 91 12 12.1.4 Designs The 3.1 Designs - Summary window provides an overview of the relevant designs. 12.1.4.1 Part of Joint in Compression Figure 12.11: Window 3.1 Designs - Summary, Part of the joint in compression Stress concentration factor 𝑎1 = 𝑏1 = min ⎧ { ⎨ { ⎩ ℎ 𝑝 + 2 (𝑎 − ℎ 𝑝) = 210 + 2 (1,000 − 210) = 1,790 mm 3ℎ 𝑝 = 3 ⋅ 210 = 630 mm ℎ 𝑝 + ℎfooting = 210 + 400 = 610 mm 𝑘 𝑗 = √ 𝑎1 𝑏1 ℎ 𝑝 𝑏 𝑝 = √ 610 ⋅ 610 220 ⋅ 210 = 2.82 Bearing strength of the foundation 𝑓 𝑗 ,𝑑 = 𝛽 𝑗 𝑘 𝑗 𝑓 𝑐 𝑑 = 2 3 ⋅ 2.82 ⋅ 1.13 = 2.13 kN/cm2 [1] , Equation (6.6)
  • 93. 12 Examples © Dlubal Software GmbH 2015 92 12 Base plate overlap 𝑐 = 𝑡 𝑝√ 𝑓 𝑦,𝑘 3𝑓 𝑗 ,𝑑 𝛾 𝑀 0 = 4.0√ 23.5 3 ⋅ 2.13 ⋅ 1.0 = 7.67 cm [1] , Equation (6.5) 𝑐1 = 7.67 cm ≥ 𝑢 = 1.0 cm 𝑐2 = 7.67 cm ≤ ℎ 𝑐 − 2𝑡 𝑓 ,𝑐 2 = 19.0 − 2 ⋅ 1.0 2 = 8.5 cm 𝑐3 = 7.67 cm ≥ 𝑢 = 1.0 cm 𝑏 𝑒𝑓 𝑓 = 𝑢 + 𝑡 𝑓 ,𝑐 + 𝑐2 = 1.0 + 1.0 + 7.67 = 9.67 cm 𝑙 𝑒𝑓 𝑓 = 𝑏 𝑐 + 2𝑐3 = 20.0 + 2 ⋅ 1.0 = 22.0 cm 𝐴 𝑐,1 = 𝑏 𝑒𝑓 𝑓 𝑙 𝑒𝑓 𝑓 = 9.67 ⋅ 22.0 = 212.74 cm2 𝐴 𝑐,2 = (𝑡 𝑤,𝑐 + 2𝑐2) (ℎ 𝑐 − 2𝑡 𝑓 ,𝑐 − 2𝑐2) = (0.65 + 2 ⋅ 7.67) (19.0 − 2 ⋅ 1.0 − 2 ⋅ 7.67) = 26.54 cm2 𝐴 𝑐,3 = 𝑏 𝑒𝑓 𝑓 𝑙 𝑒𝑓 𝑓 = 9.67 ⋅ 22.0 = 212.74 cm2 𝐴 𝑐,0 = 𝐴 𝑐,1 + 𝐴 𝑐,2 + 𝐴 𝑐,3 = 452.02 cm2 The total design compression resistance results from the summed up resistances of the T-stub: 𝐹 𝑐,𝑅 𝑑= 𝐴 𝑐,0 𝑓 𝑗 ,𝑑 = 452.02 ⋅ 2.13 = 962.80 kN [1] , Equation (6.4) Check: 𝑁 𝑐,𝐸 𝑑 𝐹 𝑐,𝑅 𝑑 = 580.00 962.80 = 0.60 ≤ 1.00 [1] , Clause 6.2.8.2
  • 94. 12 Examples © Dlubal Software GmbH 2015 93 12 12.1.4.2 Shear Resistance of Joint Figure 12.12: Window 3.1 Designs - Summary, Shear resistance of the joint Friction between base plate and grout 𝐹 𝑓 ,𝑅 𝑑= 𝐶 𝑓 ,𝑑 𝑁 𝑐,𝐸 𝑑 [1] , Equation (6.1) 𝐶 𝑓 ,𝑑 = 0.20 𝑁 𝑐,𝐸 𝑑= −580 kN 𝐹 𝑓 ,𝑅 𝑑= 0.20 ⋅ | − 580 kN| = 116 kN Check: 𝑉 𝐸 𝑑 𝐹 𝑓 ,𝑅 𝑑 = 100 116 = 0.86 ≤ 1.00 The shear force can be removed by the friction resistance. It is not necessary to implement any other measures, for example dowels.
  • 95. 12 Examples © Dlubal Software GmbH 2015 94 12 12.1.4.3 Welds The welds are designed for the column flanges and the column web. Column flange Figure 12.13: Window 3.1 Designs - Summary, Column flanges to base plate 𝜎⊥ = 𝜏⊥ = 𝑁 𝑑 √ 2𝐴 𝑤 ≤ 0.9 𝑓 𝑢 𝛾 𝑀 2 [1] , Equation (4.1) 𝜎⊥ = 𝜏⊥ = 580.00 √ 2 ⋅ 39.32 ≤ 0.9 36.00 1.25 𝜎⊥ = 𝜏⊥ = 10.43 kN/cm2 ≤ 25.90 kN/cm2 Check: 10.43 25.90 = 0.40 ≤ 1.00 𝜎 𝑤 = √ 𝜎2 ⊥ + 3 (𝜏 2 ⊥ + 𝜏 2 ∥ ) ≤ 𝑓 𝑢 𝛽 𝑤 𝛾 𝑀 2 [1] , Equation (4.1) 𝜎 𝑤 = √10.432 + 3 (10.432 + 02 ) ≤ 36.00 0.8 ⋅ 1.25 𝜎 𝑤 = 20.86 kN/cm2 ≤ 36.00 kN/cm2 Check: 20.86 36.00 = 0.58 ≤ 1.00