SCHOOL OF ARCHITECTURE, BUILDING AND DESIGN
Bachelor of Science (Hons) in Architecture
Building Science 2 (ARC 3413 / BLD61303)
Project 1b: Acoustic Performance Evaluation and Design
Tutor:Sivaraman Kuppusamy
Prepared by:
Chen EeDong0321181
EuniceChan Yu Ming0315729
FooWei Min 0321577
Koh Kar Yi 0320567
Saravanan Vytelingum 0320564
Teo Chen Yi 0320618
CONTENTPAGE
1.0 INTRODUCTION
1.1 Aim and Objective
1.2 Site Information
1.2.1 Site Introduction
1.2.2 Site Selection
1.2.3 Technical Drawings
2.0 PRECEDENT STUDIES
2.1 Introduction
2.2 Acoustic Properties
2.3 Existing Design
2.4 New Design
2.5 Conclusion
3.0 RESEARCH METHODOLOGY
3.1 Acoustic Measuring Equipment
3.2 Methodology
3.3 Data Collection Method
3.4 Limitation
3.5 Zoning
4.0 ANALYSIS
4.1 Zone A (Bar Area)
4.1.1 Locations of Noise Sources
4.1.2 Material and Properties
4.1.3 Sound Meter Reading
4.1.4 Sound Intensity Level (SIL)
4.1.4.1 Peak Period
4.1.4.2 Non-Peak Period
4.1.5 Reverberation Time (RT)
4.1.6 Sound Reduction Index (SRI)
4.1.7 Photographic observation
4.2 Zone B (Dining Area)
4.2.1 Locations of Noise Sources
4.2.2 Material and Properties
4.2.3 Sound Meter Reading
4.2.4 Sound Intensity Level (SIL)
4.1.4.1 Peak Period
4.1.4.2 Non-Peak Period
4.2.5 Reverberation Time (RT)
4.2.6 Sound Reduction Index (SRI)
4.2.7 Photographic observation
5.0 CONCLUSION
6.0 BIBLIOGRAPHY
1.0INTRODUCTION
1.1 Aim and Objective
This project is mainly aimed to help students understand the acoustic characteristics
and the requirement in a suggested space. A few calculations will be done to assist the
analysis. They are sound intensity level (SIL) which determines sound power per unit area,
reverberation time (RT) which is the prolongation of sound as a result of successive
reflections and sound reduction index (SRI) which measures the number of decibels lost
when transmitted through a partition wall.
1.2 Site Information
1.2.1 Site Introduction
Building proposed is a 8000-square-feet Korean – operated headquarters factory café
established byKeith, located in the industrial areaat Sunway Damansara.It is a two – storeys
building with orange fencing connected with Mayekawa MyCom, renovated from industrial-
like warehouse space, hiding from the busy shopping malls in Petaling Jaya. With its modern
and contemporary interior hailed from Korea juxtaposing with its factory raw exterior look,
Bean Brothers Coffee Malaysia scores significant points and this makes them a hit for all
social influencers. In the ground floor are old bricks wall in white that stacks up to towards
the high ceiling and numbers of slender dark steel pillars, giving a raw and rustic feel to the
environment. Bar counter in the center of the café below the void allow costumer at 1st floor
to overlook barista at work whereas the wooden as well as barrel ‘table’ go around the 360
degree area to cater crowds during peak hour.
Building Identification: Cuisine Café
Location: Jalan PJU 3/50, Sunway Damansara Petaling Jaya Selangor
Opening Hours: 9AM – 8PM
Figure 1.1: Photograph showing exterior view of the
site. (Source: Malaysian Flavor, 2015)
Figure 1.2: Photograph showing interior view of
the site. (Source: Malaysian Flavor, 2015)
1.2.2 Site Selection
One of the reason why this place is chosen is that it is an extremely spacious coffee
barthat scoressignificant points with variousphotogeniccorners,mainly contributed bythe
lighting design, the primary element in Architecture Design. In addition, it stands out from
the other coffee bar due to its location and context at industrial area. With this given
opportunity, we would like to evaluate this social-media-famous café and understand the
impact of building design and material on acoustic qualities. Evaluation will be carried out
to understand how the acoustic quality can be achieved in its open interior finished by
variousbuilding materials such asconcreteand steel frameandhow it is affectedbythe open
kitchen and bar area.
1.2.3 Technical Drawings
Figure 1.3: Ground Floor Plan. (Source:
Keith. 2016)
Figure 1.4: First Floor Plan.
(Source: Keith. 2016)
2.0PRECEDENT STUDIES
Case study: The Music Café, August Wilson Center
Location: Pittsburgh, PA, United States
Acoustic: ArupAcoustic
2.1 Introduction
The music café can be accessible directly from the street, it is located at the sidewalk
level from within the center. The area serves as a traditional museum café originally and a
sidewalk caféduringthe day. Thereis aseating terraceadjacent to the café, designedto lodge
a varied range of emerging technologies with wired internet access, electronic link are
provided to all international visitors.
Furthermore, the café is also designed to lodge a series of programs and to perform
as an unconventional performance space for intimate performances with limited seating
during the night. A portable stage and theatrical lighting will be imported to support such
performances as required.
Figure 2.1: Photograph showing exterior of Music Café.
(Source: Culture District, n.d.)
Figure 2.2: Photograph showing
interior of Music Café. (Source:
Culture District, n.d.)
2.2 Acoustic Properties
A building designwith acoustical design elements is essential. The building hasa large
rectangular massing with three glass sides, however, it provides sufficient acoustic
properties such as a hard floor, a sound absorbing treatment on the ceiling, hanging metal
baffles and acoustical blanket over 80% of the underside of the floor structure above.
According to the architect, a reverberation time of approximately 1.0 second is ideal
as this would place the space somewhere between speech and music use. Architectural
Acoustics: Principles and Design stated: a very high STC value around 60+ would be
desirable. This is important to both spaces, as a spoken word performance in the café could
sufferif ahugecrowd wasgathering in the lobbyforaperformancein the main theater, while
the lobbymust remain quiet duringa performanceinthe main theater if patronsareentering
or exiting the auditorium since a main set of doors is directly across from the café.
Figure 2.3: Hard Floor.
(Source: Pullen, n.d.)
Figure 2.4: Sound Absorbing Treatment.
(Source: AliExpress, n.d.)
Figure 2.5: Hanging Metal Baffles.
(Source: Acoustical Surfaces, n.d.)
Figure 2.6: Acoustic Blanket.
(Source: All Noise Control, n.d.)
2.3 Existing Design
Figure 2.7: Music café reflected ceiling plan – Existing Design.
(Source: AE Senior Thesis, n.d.)
REVERBERATION TIME SUMMARY: MUSIC CAFÉ (EXISTING)
Freq (Hz.) 125 250 500 1000 2000 4000
T60 = 1.677 2.596 0.801 0.798 0.807 0.752
Figure 2.8: Music café reverberation time – Existing Design.
(Source: AE Senior Thesis, n.d.)
Figures above prove that the existing reverberation times are far-off from the ideal.
However, the manufacturer of the metal baffle ceiling system has been omitted from the
calculation because it does not have acoustical data for the product. Additional of baffles in
the calculation would likely to reduce high reverberation times at lower frequencies and
higher frequencies which are already lower than ideal.
2.4 New Design
Figure 2.9: Music café reflected ceiling plan – New Design.
(Source: AE Senior Thesis, n.d.)
REVERBERATION TIME SUMMARY: MUSIC CAFÉ (NEW)
Freq (Hz.) 125 250 500 1000 2000 4000
T60 = 1.620 1.243 0.984 1.054 1.077 1.065
Figure 2.10: Music café reverberation time – Existing Design.
(Source: AE Senior Thesis, n.d.)
BAFFLES – MUSIC CAFE
TAG QUANTITY LENGTH
(FT)
WIDTH
(FT)
PANEL
TYPE A
28 8’-0’’ 2’-6’’
PANEL
TYPE B
28 3’-6’’ 2’-6’’
Figure 2.11: Music Café New Baffle Schedule of Materials.
(Source: AE Senior Thesis, n.d.)
2.5 Conclusion
The new reverberation times are very close to the desired values. According to
Architectural Acoustics: Principles and Design finest reverberation times at 125 have to be
1.3 times the ideal reverberation time at 500 hertz and a multiplier of 1.15 should be used at
250 hertz. These multipliers are used to correct for the fact that the human ear is less
sensitive at lower frequencies. With these factors included, the new design is very near the
target. The new ceiling system will provide superior acoustical performance at a reduced
cost.
3.0 RESEARCH METHODOLOGY
3.1 Acoustic Measuring Equipment
Figure 3.3: Camera
meter. (Source: REED,
n.d.)
It is used to measure the
sound levels at each
intersection of gridlines
at the site. The readings
displayed are in decibel
(dB).
Figure 3.2: Measuring tape.
(Source: REED, n.d.)
It is used to find the
intersections of grid line
on site for data
recording.
Figure 3.1: Sound level meter.
(Source: REED, n.d.)
It is used to
record materials
of furniture and
building
components
used.
3.2 Methodology
a) Research on different types of spaces and choose a suitable enclosed space for
acoustic study.
b) Obtain approval from the owner and conduct visitation to the chosen site.
c) Measure and sketch the rough building layout before getting the proper plans from
the owner.
d) Set gridline at 3m x 3m.
e) Distribute tasks among group members.
f) Collect data based of proper procedure.
g) Observe and record noise sources.
h) Tabulate data.
i) Carry out calculation and analysis.
3.3 Data Collection Procedure
a) Prepare gridlines of 3m x 3m on the floor plan.
b) Stand at every intersection of gridlines and hold the device at 1m from the ground.
c) Remain silent and record after the reading becomes stable.
d) Record the possible sound source at each intersection point.
e) Repeat step a to d for another period of time (peak/non-peak).
3.4 Limitation
 Environmental factor
Due to high sensitivity of sound meter, the reading is very susceptible to
surrounding sound, eg: wind and vehicle.
 Human error
Differences in height levels can affect the reading of sound meter. Also, different
manipulators have different height, leading to inaccuracy of result.
3.5 Zonings
Zone A is a bar area. It is near the bar
counter where the baristas brew coffee
and where foods are ordered and paid.
It has a total area of 138.39m2 and a total
of 20 intersections of gridlines.
Zone B is a spacious area used for dining.
There are different types and
arrangements of furniture.
It has a total area of 91.11m2 and a total of
12 intersections of gridlines.
Figure 3.4: Plan with zonings.
4.0 ANALYSIS
4.1 Zone A (Bar Area)
4.1.1 Location of Noise Sources
Figure 4.1: Identification of noise sources found in the building.
Indication Noise Source Specification Units
Speaker Product Name Bosch LC2-PC30G6-4 4
Power Handling 50W
Frequencies
Response
65Hz-20kHz
Input
Configuration
70V/100V
Sound Pressure
Level
35-45dB
Placement Wall
Air-conditioning Product Name Daikin FFR15CV1 4
Total Power 940W
Cooling Operation 12500 Btu/hr
Sound Pressure
Level
38-45 db
Placement Ceiling
Fan Product Name Panasonic Ceiling Fan PSN-
FM15E2
2
Total Power 30W
Sound Pressure
Level
35-45dB
Placement Ceiling
Electric Appliances Product Name Mastrena Starbucks
Espresso Machine CTS2
801
3
Total Power 800W
Sound Pressure
Level
82-87
Placement Bar
4.1.2 Material and Properties
No. Materials Colour Absorption (Hz) Surface
500 2000 4000
1. Clear epoxy floor finishing Grey 0.01 0.01 0.01 Smooth
2. Concrete wall Grey 0.01 0.02 0.05 Semi-
Smooth
3. Concrete Ceiling Grey 0.01 0.02 0.05 Semi-
Smooth
4. Concrete blocks wall Light Grey 0.31 0.39 0.25 Rough
5. Glass Transparent 0.03 0.02 0.02 Smooth
6. Stainless steel table top Silver 0.25 0.15 0.15 Smooth
7. Paper drum table (Aluminum
top)
Silver 0.4 0.43 0.4 Smooth
8. Steel stool Black 0.40 0.43 0.40 Smooth
9. Laminated wood tables and
chairs
Light Brown 0.15 0.18 0.20 Semi-
Smooth
10. Leather cushion Black 0.58 0.58 0.50 Smooth
4.1.3 Sound Meter Reading
Figure 4.4: Plan showing sound meter readings during peak period.
Figure 4.5: Plan showing sound meter readings during non-peak period.
4.1.4 Sound Intensity Level (SIL)
4.1.4.1 Peak Period
Highest readings: 75.9, 76.3, 80.7
𝐼𝑡𝑜𝑡𝑎𝑙 = (3.890 x 10−5
) + (4.266 x 10−5
) + (1.175 x 10−5
)
= 9.331 x 10−5
Hence, SIL = 10log (
𝐼
𝐼𝑜
)
= 10log (
9.331 𝑥 10 −5
𝐼 𝑥 10−12 )
= 79.70 dB
The sound intensity level at Zone A during peak hour is 79.70dB.
SIL = 10log (
𝐼 𝐴
1𝑜
)
75.9 = 10log (
𝐼 𝐴
1 𝑥 10−12 )
7.59 = log (
𝐼𝐴
1 𝑥 10−12 )
107.59
= (
𝐼𝐴
1 𝑥 10−12 )
IA = (1x10−12
) x (107.59
)
= 3.890 x 10−5
SIL = 10log (
𝐼 𝐵
1𝑜
)
76.3 = 10log (
𝐼 𝐵
1 𝑥 10−12 )
7.63 = log (
𝐼 𝐵
1 𝑥 10−12 )
107.63
= (
𝐼 𝐵
1 𝑥 10−12 )
IB = (1x10−12
) x (107.63
)
= 4.266 x 10−5
SIL = 10log (
𝐼 𝐶
1𝑜
)
80.7 = 10log (
𝐼 𝐶
1 𝑥 10−12 )
8.07 = log (
𝐼 𝐶
1 𝑥 10−12 )
108.07
= (
𝐼 𝐶
1 𝑥 10−12 )
IC = (1x10−12
) x (108.07
)
= 1.175 x 10−5
4.1.4.2 Non-Peak Period
Highest readings: 66.1, 66.9, 66.8
𝐼𝑡𝑜𝑡𝑎𝑙 = (4.074 x 10−6
) + (4.898 x 10−6
) + (4.786 x 10−6
)
= 1.376 x 10−5
Hence, SIL = 10log (
𝐼
𝐼𝑜
)
= 10log (
1.376 𝑥 10−5
𝐼 𝑥 10−12 )
= 71.39 dB
The sound intensity level at Zone A during non-peak hour is 71.39dB.
SIL = 10log (
𝐼 𝐴
1𝑜
)
66.1 = 10log (
𝐼𝐴
1 𝑥 10−12 )
6.61 = log (
𝐼𝐴
1 𝑥 10−12 )
106.61
= (
𝐼𝐴
1 𝑥 10−12 )
IA = (1x10−12
) x (106.61
)
= 4.074 x 10−6
SIL = 10log (
𝐼 𝐵
1𝑜
)
66.9 = 10log (
𝐼 𝐵
1 𝑥 10−12 )
6.69 = log (
𝐼 𝐵
1 𝑥 10−12 )
106.69
= (
𝐼 𝐵
1 𝑥 10−12 )
IB = (1x10−12
) x (106.69
)
= 4.898 x 10−6
SIL = 10log (
𝐼 𝐶
1𝑜
)
66.8 = 10log (
𝐼 𝐶
1 𝑥 10−12 )
6.68 = log (
𝐼 𝐶
1 𝑥 10−12 )
106.68
= (
𝐼 𝐶
1 𝑥 10−12 )
IC = (1x10−12
) x (106.68
)
= 4.786 x 10−6
4.1.5 Reverberation Time (RT)
Volume of Zone A = 484.36m3
Material absorption coefficient at 500Hz
Component Material Surface
Area (m2)
/
Quantity
Absorption
Coefficient
Sound
Absorptio
n
Floor Clear epoxy floor finishing 138.39 0.01 1.38
Wall Concrete blocks wall plaster finish 59.37 0.31 18.40
Exposed concrete blocks 44.45 0.25 11.11
Glass 19.50 0.03 0.59
Ceiling Concrete 57.65 0.01 0.58
Furniture Stainless steel table top 2 0.25 0.50
Paper drum table ( Aluminum) 8 0.40 3.20
Steel stool 24 0.40 9.60
Laminated wood tables 2 0.15 0.30
Occupants 25 0.46 11.50
Total Absorption (A) 57.16
RT =
0.16 𝑥 484 .36
57.16
= 1.36s
Material absorption coefficient at 2000Hz
Component Material Surface
Area (m2)
/
Quantity
Absorption
Coefficient
Sound
Absorption
Floor Clear epoxy floor finishing 138.39 0.01 1.38
Wall Concrete blocks wall plaster finish 59.37 0.39 23.15
Exposed concrete blocks 44.45 0.30 13.34
Glass 19.50 0.02 0.39
Ceiling Concrete 57.65 0.02 1.15
Furniture Stainless steel table top 2 0.15 0.30
Paper drum table ( Aluminum) 8 0.43 3.44
Steel stool 24 0.43 10.32
Laminated wood tables 2 0.18 0.36
Occupants 25 0.51 12.75
Total Absorption (A) 66.58
RT =
0.16 𝑥 484 .36
66.58
= 1.16s
4.1.6 Sound Reduction Index (SRI)
There is no separation of quiet zone from the open bar, dining and even kitchen area
hence no partition wall can be found in the chosen study area. Therefore, a wall that
separates the open area and store room will be taken as an example to show the calculation
for sound reduction index.
Figure 4.6: Elevation of interior wall.
Component Surface Area (m2), S
Sound Reduction
Index, T
Transmission
Coefficient,
T= 1/log-1 (T/10)
Concrete Block
Wall
25 42 6.310 x 10-5
Wooden Door 2 28 1.585 x 10-3
Tav = (S1T1 + S2T2)/(S1+S2)
= [25(6.310 x 10-5) + 2(1.585 x 10-3)]/(25+2)
= 1.758 x 10-4
Overall SRI = 10 log (1/ 1.758 x 10-4)
= 37.55dB
4.1.7 Photographic observation
The café is located in Jalan PJU, the cornerslotnext to the industrial areaandadjacent
to residential area, Sunway Rymba Hill, therefore vehicle circulation in front of the site is
quite low as the end of the road only consist of high end residence.
Human noises are high in the café especially in zone B due to the fact that it is mostly
tables filled with customers doing activities such as chit-chatting, laughing and etc. Other
than that, there are also noises coming from zone B, the baristas’ area, human noise level is
solely based on reception activities and customer from café lounge.
Figure 4.7: Mayekawa (M) Sdn Bhd, factory next to
Bean Brother.
Figure 4.8: Rymba Hill, adjacent to the Bean
Brother.
Figure: Zone C, social activities happen
during peak hour (Source)
Figure 4.9: Zone B, social activities happen during
peak hour.
Figure 4.10: Café lounge in front of the barista area.
Speakers are distributed throughout the building for the purpose of playing soft
music during opening hour.
Figure 4.11: Speakers located at the every possible wall throughout the building.
Appliances at the barista such as coffee maker and cooler which generate cool air
to keep cakes and dessert fresh produce noise on its own. Furthermore, noises from the
open kitchen which produce by the fiction of appliances also contribute certain amount
of turbulence and clearly hearable.
Ceiling Cassette Unit are found
distributed evenly to cover most of
the area. They are high in power and
produce relatively low noise.
Figure 4.12: Café lounge in front of the barista area.
Figure 4.13: Barista in the middle of the
building.
Figure 4.14: Open kitchen.
4.2 Zone B (Dining Area)
4.2.1 Locations of Noise Sources
Figure 4.15: Identification of noise sources found in the building.
Indication Noise Source Specification Units
Speaker Product Name Bosch LC2-PC30G6-4 3
Power Handling 50W
Frequencies
Response
65Hz-20kHz
Input
Configuration
70V/100V
Sound Pressure
Level
35-45dB
Placement Wall
Air-conditioning Product Name Daikin FFR15CV1 2
Total Power 940W
Cooling Operation 12500 Btu/hr
Sound Pressure
Level
38-45 db
Placement Ceiling
Fan Product Name Panasonic Ceiling Fan
PSN-FM15E2
2
Total Power 155W
Sound Pressure
Level
35-45dB
Placement Ceiling
4.2.2 Material and Properties
No. Materials Colour Absorption (Hz) Surface
500 2000 4000
1. Clear epoxy floor finishing Grey 0.01 0.01 0.01 Smooth
2. Concrete wall Grey 0.01 0.02 0.05 Semi-
Smooth
3. Concrete Ceiling Grey 0.01 0.02 0.05 Semi-
Smooth
4. Concrete blocks wall Light Grey 0.31 0.39 0.25 Rough
5. Glass Transparent 0.03 0.02 0.02 Smooth
6. Stainless steel table top Silver 0.25 0.15 0.15 Smooth
7. Paper drum table (Aluminum
top)
Silver 0.4 0.43 0.4 Smooth
8. Steel stool Black 0.40 0.43 0.40 Smooth
9. Laminated wood tables and
chairs
Light Brown 0.15 0.18 0.20 Semi-
Smooth
10. Leather cushion Black 0.58 0.58 0.50 Smooth
4.2.2 Sound Meter Reading
Figure 4.16: Plan showing sound meter readings during peak period.
Figure 4.17: Plan showing sound meter readings during non-peak period.
4.2.3 Sound Intensity Level (SIL)
4.1.3.1 Peak Period
Highest readings: 77.2, 76.0, 76.2
𝐼𝑡𝑜𝑡𝑎𝑙 = (5.248 x 10−5
) + (3.981 x 10−5
) + (4.169 x 10−5
)
= 1.340 x 10−4
Hence, SIL = 10log (
𝐼
𝐼𝑜
)
= 10log (
1.340 𝑥 10−4
𝐼 𝑥 10−12 )
= 81.27 dB
The sound intensity level at Zone B during peak hour is 81.27dB.
SIL = 10log (
𝐼 𝐴
1𝑜
)
77.2 = 10log (
𝐼 𝐴
1 𝑥 10−12 )
7.72 = log (
𝐼𝐴
1 𝑥 10−12 )
107.72
= (
𝐼𝐴
1 𝑥 10−12 )
IA = (1x10−12
) x (107.72
)
= 5.248 x 10−5
SIL = 10log (
𝐼 𝐵
1𝑜
)
76.0 = 10log (
𝐼 𝐵
1 𝑥 10−12 )
7.60 = log (
𝐼 𝐵
1 𝑥 10−12 )
107.60
= (
𝐼 𝐵
1 𝑥 10−12 )
IB = (1x10−12
) x (107.60
)
= 3.981 x 10−5
SIL = 10log (
𝐼 𝐶
1𝑜
)
76.2 = 10log (
𝐼 𝐶
1 𝑥 10−12 )
7.62 = log (
𝐼 𝐶
1 𝑥 10−12 )
107.62
= (
𝐼 𝐶
1 𝑥 10−12 )
IC = (1x10−12
) x (107.62
)
= 4.169 x 10−5
4.1.3.2 Non-Peak Period
Highest readings: 65.3, 66.3, 66.3
𝐼𝑡𝑜𝑡𝑎𝑙 = (3.388 x 10−6
) + (4.266 x 10−6
) + (4.266 x 10−6
)
= 1.192 x 10−5
Hence, SIL = 10log (
𝐼
𝐼𝑜
)
= 10log (
1.192 𝑥 10 −5
𝐼 𝑥 10−12 )
= 70.76 dB
The sound intensity level at Zone B during non-peak hour is 70.76dB.
SIL = 10log (
𝐼 𝐴
1𝑜
)
65.3 = 10log (
𝐼𝐴
1 𝑥 10−12 )
6.53 = log (
𝐼𝐴
1 𝑥 10−12 )
106.53
= (
𝐼𝐴
1 𝑥 10−12 )
IA = (1x10−12
) x (106.53
)
= 3.388 x 10−6
SIL = 10log (
𝐼 𝐵
1𝑜
)
77.2 = 10log (
𝐼 𝐵
1 𝑥 10−12 )
7.72 = log (
𝐼 𝐵
1 𝑥 10−12 )
107.72
= (
𝐼 𝐵
1 𝑥 10−12 )
IB = (1x10−12
) x (107.72
)
= 4.266 x 10−6
SIL = 10log (
𝐼 𝐶
1𝑜
)
77.2 = 10log (
𝐼 𝐶
1 𝑥 10−12 )
7.72 = log (
𝐼 𝐶
1 𝑥 10−12 )
107.72
= (
𝐼 𝐶
1 𝑥 10−12 )
IC = (1x10−12
) x (107.72
)
= 4.266 x 10−6
4.2.4 Reverberation Time (RT)
Volume of Zone B = 329.38m3
Material absorption coefficient at 500Hz
Component Material Surface
Area (m2)
/
Quantity
Absorption
Coefficient
Sound
Absorption
Floor Clear epoxy floor finishing 94.11 0.01 0.94
Wall Concrete with plaster finish 19.15 0.05 0.96
Concrete blocks wall plaster finish 151.34 0.31 46.92
Exposed concrete blocks 12.32 0.25 3.08
Glass 17.68 0.03 0.53
Ceiling Concrete 89.53 0.01 0.90
Furniture Steel stool 28 0.40 11.20
Laminated wood tables 15 0.15 2.25
Leather cushion 2 0.58 1.16
Occupants 8 0.46 3.68
Total Absorption (A) 71.62
RT =
0.16 𝑥 484 .36
71.62
= 1.08s
Material absorption coefficient at 2000Hz
Component Material Surface
Area (m2)
/
Quantity
Absorption
Coefficient
Sound
Absorption
Floor Clear epoxy floor finishing 94.11 0.01 0.94
Wall Concrete with plaster finish 19.15 0.09 1.72
Concrete blocks wall plaster finish 151.34 0.39 59.02
Exposed concrete blocks 12.32 0.30 3.70
Glass 17.68 0.02 0.35
Ceiling Concrete 89.53 0.02 1.79
Furniture Steel stool 28 0.43 12.04
Laminated wood tables 15 0.18 2.70
Leather cushion 2 0.58 1.16
Occupants 8 0.46 3.68
Total Absorption (A) 87.10
RT =
0.16 𝑥 484 .36
87.10
= 0.89s
4.2.6 Photographic observation
Speakers are distributed throughout the building for the purpose of playing soft music
during opening hour.
Figure 4.18: Speakers located throughout the building.
Figure 4.19: Café lounge in front of the barista area.
Fans are found on the area that
are not covered by the air
conditioner. Produce certain
amount of noises but noises
often covered by the noises of
human activities and not till
extend which will distract and
affect the customers nearby.
5.0 CONCLUSION
Type of occupancy
& activities
Recommended
reverberation time
Coffee bars 45 50 <1.0
Restaurant 45 50 <1.0
Recommended design sound level of a coffee bars and restaurants should be in the
average of 45db to 50dB with the recommended time of less than 1.00s by according to
AS/ZS 2107:2000 standard for reverberation time and sound levels.
Zones Sound Pressure Level
(dB)
Reverberation Time (s)
500Hz
Reverberation Time (s)
2000Hz
A 79.70 dB , 71.39dB 1.36s 1.16s
B 81.27 dB, 70.76dB 1.08s 0.89s
It can be concluded that both two zones did not meet the minimum requirement of
the acoustic standard for 500Hz except for zone B which has less than 1.00s reverberation
time for 2000Hz. This is due to the selections of material, material that has been used cannot
absorb sounds efficiently.
From the table above, it is clear that zone B has the highest sound pressure level
during peak hours due to the amount of human activities and noise sources of the
surrounding. Furthermore, open space concept of the café has also led to the high sound
pressure level, for instance, due the open ceiling of the ground floor, noises from the first
floor can be transmitted to the ground floor.
Satisfactory
ySatisfactory
Maximum
y
Satisfactory
6.0 BIBLIOGRAPHY
1. Malaysian Flavor. (2015). Bean Brothers Malaysia @ Sunway Damansara. Retrieved from
http://www.malaysianflavours.com/2015/09/bean-brothers-malaysia-sunway-
damansara-pj.html
2. Culture District. (N.d). August Wilson Center. Retrieved from
https://culturaldistrict.org/pages/awc
3. Pullen. (N.d). Eco Friendly Wood Floor. Retrieved from
http://greenliving.lovetoknow.com/Eco_Friendly_Wood_Floor
4. Reed. (N.d). REED C-322 Sound Level Meter/Data Logger, 32 to 130dB. Retrieved from
http://www.reedinstruments.com/product/reed-instruments-c-322-sound-level-meter-
data-logger
5. AliExpress. (N.d). Acoustic Foam. Retrieved from
https://www.aliexpress.com/w/wholesale-acoustic-foam.html
6. Acoustical Surfaces (N.d). Echo Eliminator. Retrieved from
http://www.acousticalsurfaces.com/echo_eliminator/ee_hangbaf.htm
7. All Sound Control. (N.d). Outdoor Noise Control Blankets. Retrieved from
http://www.allnoisecontrol.com/outdoor-noise-control-blankets.cfm
8. AE Senior Thesis. (N.d). – August Wilson Center. Retrieved from
https://www.engr.psu.edu/ae/thesis/portfolios/2008/mpr184/files/final_report/Section
5_Acoustics.pdf

More Related Content

What's hot

Project 1-Lighting & Acoustic Performance Evaluation and Design
Project 1-Lighting & Acoustic Performance Evaluation and DesignProject 1-Lighting & Acoustic Performance Evaluation and Design
Project 1-Lighting & Acoustic Performance Evaluation and DesignAngeline KH
 
Building Science 1 (Project 1)
Building Science 1 (Project 1)Building Science 1 (Project 1)
Building Science 1 (Project 1)Soh Shing
 
BUILDING SCIENCE II: ACOUSTICS AND LIGHTING ANALYSIS OF DONUTES CAFE, SS15
BUILDING SCIENCE II: ACOUSTICS AND LIGHTING ANALYSIS OF DONUTES CAFE, SS15BUILDING SCIENCE II: ACOUSTICS AND LIGHTING ANALYSIS OF DONUTES CAFE, SS15
BUILDING SCIENCE II: ACOUSTICS AND LIGHTING ANALYSIS OF DONUTES CAFE, SS15JoyeeLee0131
 
Building science report ...
Building science report                                                      ...Building science report                                                      ...
Building science report ...Tsang Hao Ren
 
Lighting & Acoustic Performance Evaluation and Design
Lighting & Acoustic Performance Evaluation and DesignLighting & Acoustic Performance Evaluation and Design
Lighting & Acoustic Performance Evaluation and Designnadiacbass
 
Building science 2
Building science 2Building science 2
Building science 2Baddy Peigun
 
Building Science Report
Building Science ReportBuilding Science Report
Building Science ReportLiew Hong Zhi
 
Bscience report
Bscience reportBscience report
Bscience reportkerneng
 
Building science 2 project 1
Building science 2 project 1Building science 2 project 1
Building science 2 project 1Jannah Jailani
 
Building Science Project 2 Report
Building Science Project 2 ReportBuilding Science Project 2 Report
Building Science Project 2 ReportPatricia Kong
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilationkerneng
 
Bscience 2-project-2
Bscience 2-project-2Bscience 2-project-2
Bscience 2-project-2Megan Chung
 
B.science report 1.2
B.science report 1.2B.science report 1.2
B.science report 1.2Elaine Bong
 
Report Bscience 2 Evaluation Performance Lighting & Acoustics
Report Bscience 2 Evaluation Performance Lighting & AcousticsReport Bscience 2 Evaluation Performance Lighting & Acoustics
Report Bscience 2 Evaluation Performance Lighting & AcousticsCrysmond Goh
 
Lighting Analysis Project 1
Lighting Analysis Project 1Lighting Analysis Project 1
Lighting Analysis Project 1J-Sern Phua
 
Building Science II
Building Science IIBuilding Science II
Building Science IIIvy Yee
 
Building Science II : Project 1
Building Science II : Project 1Building Science II : Project 1
Building Science II : Project 1Patricia Kong
 

What's hot (19)

Project 1-Lighting & Acoustic Performance Evaluation and Design
Project 1-Lighting & Acoustic Performance Evaluation and DesignProject 1-Lighting & Acoustic Performance Evaluation and Design
Project 1-Lighting & Acoustic Performance Evaluation and Design
 
Building Science 1 (Project 1)
Building Science 1 (Project 1)Building Science 1 (Project 1)
Building Science 1 (Project 1)
 
BUILDING SCIENCE II: ACOUSTICS AND LIGHTING ANALYSIS OF DONUTES CAFE, SS15
BUILDING SCIENCE II: ACOUSTICS AND LIGHTING ANALYSIS OF DONUTES CAFE, SS15BUILDING SCIENCE II: ACOUSTICS AND LIGHTING ANALYSIS OF DONUTES CAFE, SS15
BUILDING SCIENCE II: ACOUSTICS AND LIGHTING ANALYSIS OF DONUTES CAFE, SS15
 
Building science report ...
Building science report                                                      ...Building science report                                                      ...
Building science report ...
 
Lighting & Acoustic Performance Evaluation and Design
Lighting & Acoustic Performance Evaluation and DesignLighting & Acoustic Performance Evaluation and Design
Lighting & Acoustic Performance Evaluation and Design
 
Building science 2
Building science 2Building science 2
Building science 2
 
Building Science Report
Building Science ReportBuilding Science Report
Building Science Report
 
Bscience report
Bscience reportBscience report
Bscience report
 
Building science 2 project 1
Building science 2 project 1Building science 2 project 1
Building science 2 project 1
 
Building Science Project 2 Report
Building Science Project 2 ReportBuilding Science Project 2 Report
Building Science Project 2 Report
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilation
 
Bscience 2-project-2
Bscience 2-project-2Bscience 2-project-2
Bscience 2-project-2
 
B.science report 1.2
B.science report 1.2B.science report 1.2
B.science report 1.2
 
Bscience
BscienceBscience
Bscience
 
Report Bscience 2 Evaluation Performance Lighting & Acoustics
Report Bscience 2 Evaluation Performance Lighting & AcousticsReport Bscience 2 Evaluation Performance Lighting & Acoustics
Report Bscience 2 Evaluation Performance Lighting & Acoustics
 
Lighting Analysis Project 1
Lighting Analysis Project 1Lighting Analysis Project 1
Lighting Analysis Project 1
 
Final report
Final reportFinal report
Final report
 
Building Science II
Building Science IIBuilding Science II
Building Science II
 
Building Science II : Project 1
Building Science II : Project 1Building Science II : Project 1
Building Science II : Project 1
 

Similar to Final a

FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdfFINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdfOctonio Octonio
 
Auditorium: A Case Study on Acoustic Design Report
Auditorium: A Case Study on Acoustic Design ReportAuditorium: A Case Study on Acoustic Design Report
Auditorium: A Case Study on Acoustic Design Reportjisunfoo
 
SEM 5 : PROJECT 1 REPORT BUILDING SCIENCE 2
SEM 5 : PROJECT 1 REPORT BUILDING SCIENCE 2SEM 5 : PROJECT 1 REPORT BUILDING SCIENCE 2
SEM 5 : PROJECT 1 REPORT BUILDING SCIENCE 2Darshiini Vig
 
A Case Study On Room Acoustic
A Case Study On Room AcousticA Case Study On Room Acoustic
A Case Study On Room AcousticKalvin Bong
 
Building science: acoustics
Building science: acousticsBuilding science: acoustics
Building science: acousticskennett2203
 
Building Science II
Building Science IIBuilding Science II
Building Science IIjernjack
 
Bscience report ff
Bscience report ffBscience report ff
Bscience report ffAnthony Chew
 
Bscience report ff
Bscience report ffBscience report ff
Bscience report ffxinhuaee123
 
BUILDING SCIENCE II REPORT
BUILDING SCIENCE II REPORTBUILDING SCIENCE II REPORT
BUILDING SCIENCE II REPORTClaire Zhuangg
 
Building science ii report
Building science ii reportBuilding science ii report
Building science ii reportWeng Chuan
 
Acoustic Analysis on Permata Pintar Auditorium (Report)
Acoustic Analysis on Permata Pintar Auditorium (Report)Acoustic Analysis on Permata Pintar Auditorium (Report)
Acoustic Analysis on Permata Pintar Auditorium (Report)Carmen Chan
 
Building science 2 report
Building science 2 reportBuilding science 2 report
Building science 2 reportHarwinder Girn
 
Building science 2 PJT 1 report
Building science 2 PJT 1 reportBuilding science 2 PJT 1 report
Building science 2 PJT 1 reportForestedTiger
 
Building science 2 report
Building science 2 reportBuilding science 2 report
Building science 2 reportChong Yi Hui
 
Analysis and Desin of Multi purpose Auditorium
Analysis and Desin of Multi purpose AuditoriumAnalysis and Desin of Multi purpose Auditorium
Analysis and Desin of Multi purpose AuditoriumKrishna Madhukar Vadla
 
Building Science II Report
Building Science II ReportBuilding Science II Report
Building Science II ReportVansC
 

Similar to Final a (20)

FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdfFINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
FINAL REPORT PROJECT 1 LIGHTING AND ACOUSTIC PERFORMANCE.pdf
 
Auditorium: A Case Study on Acoustic Design Report
Auditorium: A Case Study on Acoustic Design ReportAuditorium: A Case Study on Acoustic Design Report
Auditorium: A Case Study on Acoustic Design Report
 
SEM 5 : PROJECT 1 REPORT BUILDING SCIENCE 2
SEM 5 : PROJECT 1 REPORT BUILDING SCIENCE 2SEM 5 : PROJECT 1 REPORT BUILDING SCIENCE 2
SEM 5 : PROJECT 1 REPORT BUILDING SCIENCE 2
 
Sound final
Sound finalSound final
Sound final
 
A Case Study On Room Acoustic
A Case Study On Room AcousticA Case Study On Room Acoustic
A Case Study On Room Acoustic
 
Building science: acoustics
Building science: acousticsBuilding science: acoustics
Building science: acoustics
 
Building Science II
Building Science IIBuilding Science II
Building Science II
 
Bscience report ff
Bscience report ffBscience report ff
Bscience report ff
 
Bscience report ff
Bscience report ffBscience report ff
Bscience report ff
 
BUILDING SCIENCE II REPORT
BUILDING SCIENCE II REPORTBUILDING SCIENCE II REPORT
BUILDING SCIENCE II REPORT
 
Building science ii report
Building science ii reportBuilding science ii report
Building science ii report
 
Acoustic Analysis on Permata Pintar Auditorium (Report)
Acoustic Analysis on Permata Pintar Auditorium (Report)Acoustic Analysis on Permata Pintar Auditorium (Report)
Acoustic Analysis on Permata Pintar Auditorium (Report)
 
Building science 2 report
Building science 2 reportBuilding science 2 report
Building science 2 report
 
Building science 2 PJT 1 report
Building science 2 PJT 1 reportBuilding science 2 PJT 1 report
Building science 2 PJT 1 report
 
Building science 2 report
Building science 2 reportBuilding science 2 report
Building science 2 report
 
Building science 2 report (1)
Building science 2 report (1)Building science 2 report (1)
Building science 2 report (1)
 
Analysis and Desin of Multi purpose Auditorium
Analysis and Desin of Multi purpose AuditoriumAnalysis and Desin of Multi purpose Auditorium
Analysis and Desin of Multi purpose Auditorium
 
Compilationd
CompilationdCompilationd
Compilationd
 
Compilation
CompilationCompilation
Compilation
 
Building Science II Report
Building Science II ReportBuilding Science II Report
Building Science II Report
 

More from Eunice Chan

Comparative analysis essay
Comparative analysis essayComparative analysis essay
Comparative analysis essayEunice Chan
 
Towards a critical regionalism
Towards a critical regionalismTowards a critical regionalism
Towards a critical regionalismEunice Chan
 
The geometry of feeling
The geometry of feelingThe geometry of feeling
The geometry of feelingEunice Chan
 
Semiology and architecture
Semiology and architectureSemiology and architecture
Semiology and architectureEunice Chan
 

More from Eunice Chan (6)

Project 2 b
Project 2 bProject 2 b
Project 2 b
 
Comparative analysis essay
Comparative analysis essayComparative analysis essay
Comparative analysis essay
 
Towards a critical regionalism
Towards a critical regionalismTowards a critical regionalism
Towards a critical regionalism
 
The geometry of feeling
The geometry of feelingThe geometry of feeling
The geometry of feeling
 
Semiology and architecture
Semiology and architectureSemiology and architecture
Semiology and architecture
 
Las vegas
Las vegasLas vegas
Las vegas
 

Recently uploaded

HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...Nguyen Thanh Tu Collection
 
Earth Day Presentation wow hello nice great
Earth Day Presentation wow hello nice greatEarth Day Presentation wow hello nice great
Earth Day Presentation wow hello nice greatYousafMalik24
 
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTiammrhaywood
 
Judging the Relevance and worth of ideas part 2.pptx
Judging the Relevance  and worth of ideas part 2.pptxJudging the Relevance  and worth of ideas part 2.pptx
Judging the Relevance and worth of ideas part 2.pptxSherlyMaeNeri
 
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfAMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfphamnguyenenglishnb
 
Full Stack Web Development Course for Beginners
Full Stack Web Development Course  for BeginnersFull Stack Web Development Course  for Beginners
Full Stack Web Development Course for BeginnersSabitha Banu
 
Difference Between Search & Browse Methods in Odoo 17
Difference Between Search & Browse Methods in Odoo 17Difference Between Search & Browse Methods in Odoo 17
Difference Between Search & Browse Methods in Odoo 17Celine George
 
DATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersDATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersSabitha Banu
 
Gas measurement O2,Co2,& ph) 04/2024.pptx
Gas measurement O2,Co2,& ph) 04/2024.pptxGas measurement O2,Co2,& ph) 04/2024.pptx
Gas measurement O2,Co2,& ph) 04/2024.pptxDr.Ibrahim Hassaan
 
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxiammrhaywood
 
Field Attribute Index Feature in Odoo 17
Field Attribute Index Feature in Odoo 17Field Attribute Index Feature in Odoo 17
Field Attribute Index Feature in Odoo 17Celine George
 
Romantic Opera MUSIC FOR GRADE NINE pptx
Romantic Opera MUSIC FOR GRADE NINE pptxRomantic Opera MUSIC FOR GRADE NINE pptx
Romantic Opera MUSIC FOR GRADE NINE pptxsqpmdrvczh
 
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxMULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxAnupkumar Sharma
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designMIPLM
 
Hierarchy of management that covers different levels of management
Hierarchy of management that covers different levels of managementHierarchy of management that covers different levels of management
Hierarchy of management that covers different levels of managementmkooblal
 
Procuring digital preservation CAN be quick and painless with our new dynamic...
Procuring digital preservation CAN be quick and painless with our new dynamic...Procuring digital preservation CAN be quick and painless with our new dynamic...
Procuring digital preservation CAN be quick and painless with our new dynamic...Jisc
 
Computed Fields and api Depends in the Odoo 17
Computed Fields and api Depends in the Odoo 17Computed Fields and api Depends in the Odoo 17
Computed Fields and api Depends in the Odoo 17Celine George
 
Quarter 4 Peace-education.pptx Catch Up Friday
Quarter 4 Peace-education.pptx Catch Up FridayQuarter 4 Peace-education.pptx Catch Up Friday
Quarter 4 Peace-education.pptx Catch Up FridayMakMakNepo
 

Recently uploaded (20)

OS-operating systems- ch04 (Threads) ...
OS-operating systems- ch04 (Threads) ...OS-operating systems- ch04 (Threads) ...
OS-operating systems- ch04 (Threads) ...
 
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
HỌC TỐT TIẾNG ANH 11 THEO CHƯƠNG TRÌNH GLOBAL SUCCESS ĐÁP ÁN CHI TIẾT - CẢ NĂ...
 
Earth Day Presentation wow hello nice great
Earth Day Presentation wow hello nice greatEarth Day Presentation wow hello nice great
Earth Day Presentation wow hello nice great
 
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
 
Judging the Relevance and worth of ideas part 2.pptx
Judging the Relevance  and worth of ideas part 2.pptxJudging the Relevance  and worth of ideas part 2.pptx
Judging the Relevance and worth of ideas part 2.pptx
 
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdfAMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
AMERICAN LANGUAGE HUB_Level2_Student'sBook_Answerkey.pdf
 
Full Stack Web Development Course for Beginners
Full Stack Web Development Course  for BeginnersFull Stack Web Development Course  for Beginners
Full Stack Web Development Course for Beginners
 
Difference Between Search & Browse Methods in Odoo 17
Difference Between Search & Browse Methods in Odoo 17Difference Between Search & Browse Methods in Odoo 17
Difference Between Search & Browse Methods in Odoo 17
 
DATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersDATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginners
 
Gas measurement O2,Co2,& ph) 04/2024.pptx
Gas measurement O2,Co2,& ph) 04/2024.pptxGas measurement O2,Co2,& ph) 04/2024.pptx
Gas measurement O2,Co2,& ph) 04/2024.pptx
 
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
 
Field Attribute Index Feature in Odoo 17
Field Attribute Index Feature in Odoo 17Field Attribute Index Feature in Odoo 17
Field Attribute Index Feature in Odoo 17
 
Romantic Opera MUSIC FOR GRADE NINE pptx
Romantic Opera MUSIC FOR GRADE NINE pptxRomantic Opera MUSIC FOR GRADE NINE pptx
Romantic Opera MUSIC FOR GRADE NINE pptx
 
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxMULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-design
 
Hierarchy of management that covers different levels of management
Hierarchy of management that covers different levels of managementHierarchy of management that covers different levels of management
Hierarchy of management that covers different levels of management
 
Procuring digital preservation CAN be quick and painless with our new dynamic...
Procuring digital preservation CAN be quick and painless with our new dynamic...Procuring digital preservation CAN be quick and painless with our new dynamic...
Procuring digital preservation CAN be quick and painless with our new dynamic...
 
Model Call Girl in Bikash Puri Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Bikash Puri  Delhi reach out to us at 🔝9953056974🔝Model Call Girl in Bikash Puri  Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Bikash Puri Delhi reach out to us at 🔝9953056974🔝
 
Computed Fields and api Depends in the Odoo 17
Computed Fields and api Depends in the Odoo 17Computed Fields and api Depends in the Odoo 17
Computed Fields and api Depends in the Odoo 17
 
Quarter 4 Peace-education.pptx Catch Up Friday
Quarter 4 Peace-education.pptx Catch Up FridayQuarter 4 Peace-education.pptx Catch Up Friday
Quarter 4 Peace-education.pptx Catch Up Friday
 

Final a

  • 1. SCHOOL OF ARCHITECTURE, BUILDING AND DESIGN Bachelor of Science (Hons) in Architecture Building Science 2 (ARC 3413 / BLD61303) Project 1b: Acoustic Performance Evaluation and Design Tutor:Sivaraman Kuppusamy Prepared by: Chen EeDong0321181 EuniceChan Yu Ming0315729 FooWei Min 0321577 Koh Kar Yi 0320567 Saravanan Vytelingum 0320564 Teo Chen Yi 0320618
  • 2. CONTENTPAGE 1.0 INTRODUCTION 1.1 Aim and Objective 1.2 Site Information 1.2.1 Site Introduction 1.2.2 Site Selection 1.2.3 Technical Drawings 2.0 PRECEDENT STUDIES 2.1 Introduction 2.2 Acoustic Properties 2.3 Existing Design 2.4 New Design 2.5 Conclusion 3.0 RESEARCH METHODOLOGY 3.1 Acoustic Measuring Equipment 3.2 Methodology 3.3 Data Collection Method 3.4 Limitation 3.5 Zoning 4.0 ANALYSIS 4.1 Zone A (Bar Area) 4.1.1 Locations of Noise Sources 4.1.2 Material and Properties 4.1.3 Sound Meter Reading 4.1.4 Sound Intensity Level (SIL) 4.1.4.1 Peak Period 4.1.4.2 Non-Peak Period 4.1.5 Reverberation Time (RT) 4.1.6 Sound Reduction Index (SRI) 4.1.7 Photographic observation
  • 3. 4.2 Zone B (Dining Area) 4.2.1 Locations of Noise Sources 4.2.2 Material and Properties 4.2.3 Sound Meter Reading 4.2.4 Sound Intensity Level (SIL) 4.1.4.1 Peak Period 4.1.4.2 Non-Peak Period 4.2.5 Reverberation Time (RT) 4.2.6 Sound Reduction Index (SRI) 4.2.7 Photographic observation 5.0 CONCLUSION 6.0 BIBLIOGRAPHY
  • 4. 1.0INTRODUCTION 1.1 Aim and Objective This project is mainly aimed to help students understand the acoustic characteristics and the requirement in a suggested space. A few calculations will be done to assist the analysis. They are sound intensity level (SIL) which determines sound power per unit area, reverberation time (RT) which is the prolongation of sound as a result of successive reflections and sound reduction index (SRI) which measures the number of decibels lost when transmitted through a partition wall. 1.2 Site Information 1.2.1 Site Introduction Building proposed is a 8000-square-feet Korean – operated headquarters factory café established byKeith, located in the industrial areaat Sunway Damansara.It is a two – storeys building with orange fencing connected with Mayekawa MyCom, renovated from industrial- like warehouse space, hiding from the busy shopping malls in Petaling Jaya. With its modern and contemporary interior hailed from Korea juxtaposing with its factory raw exterior look, Bean Brothers Coffee Malaysia scores significant points and this makes them a hit for all social influencers. In the ground floor are old bricks wall in white that stacks up to towards the high ceiling and numbers of slender dark steel pillars, giving a raw and rustic feel to the environment. Bar counter in the center of the café below the void allow costumer at 1st floor to overlook barista at work whereas the wooden as well as barrel ‘table’ go around the 360 degree area to cater crowds during peak hour. Building Identification: Cuisine Café Location: Jalan PJU 3/50, Sunway Damansara Petaling Jaya Selangor Opening Hours: 9AM – 8PM Figure 1.1: Photograph showing exterior view of the site. (Source: Malaysian Flavor, 2015) Figure 1.2: Photograph showing interior view of the site. (Source: Malaysian Flavor, 2015)
  • 5. 1.2.2 Site Selection One of the reason why this place is chosen is that it is an extremely spacious coffee barthat scoressignificant points with variousphotogeniccorners,mainly contributed bythe lighting design, the primary element in Architecture Design. In addition, it stands out from the other coffee bar due to its location and context at industrial area. With this given opportunity, we would like to evaluate this social-media-famous café and understand the impact of building design and material on acoustic qualities. Evaluation will be carried out to understand how the acoustic quality can be achieved in its open interior finished by variousbuilding materials such asconcreteand steel frameandhow it is affectedbythe open kitchen and bar area. 1.2.3 Technical Drawings Figure 1.3: Ground Floor Plan. (Source: Keith. 2016) Figure 1.4: First Floor Plan. (Source: Keith. 2016)
  • 6. 2.0PRECEDENT STUDIES Case study: The Music Café, August Wilson Center Location: Pittsburgh, PA, United States Acoustic: ArupAcoustic 2.1 Introduction The music café can be accessible directly from the street, it is located at the sidewalk level from within the center. The area serves as a traditional museum café originally and a sidewalk caféduringthe day. Thereis aseating terraceadjacent to the café, designedto lodge a varied range of emerging technologies with wired internet access, electronic link are provided to all international visitors. Furthermore, the café is also designed to lodge a series of programs and to perform as an unconventional performance space for intimate performances with limited seating during the night. A portable stage and theatrical lighting will be imported to support such performances as required. Figure 2.1: Photograph showing exterior of Music Café. (Source: Culture District, n.d.) Figure 2.2: Photograph showing interior of Music Café. (Source: Culture District, n.d.)
  • 7. 2.2 Acoustic Properties A building designwith acoustical design elements is essential. The building hasa large rectangular massing with three glass sides, however, it provides sufficient acoustic properties such as a hard floor, a sound absorbing treatment on the ceiling, hanging metal baffles and acoustical blanket over 80% of the underside of the floor structure above. According to the architect, a reverberation time of approximately 1.0 second is ideal as this would place the space somewhere between speech and music use. Architectural Acoustics: Principles and Design stated: a very high STC value around 60+ would be desirable. This is important to both spaces, as a spoken word performance in the café could sufferif ahugecrowd wasgathering in the lobbyforaperformancein the main theater, while the lobbymust remain quiet duringa performanceinthe main theater if patronsareentering or exiting the auditorium since a main set of doors is directly across from the café. Figure 2.3: Hard Floor. (Source: Pullen, n.d.) Figure 2.4: Sound Absorbing Treatment. (Source: AliExpress, n.d.) Figure 2.5: Hanging Metal Baffles. (Source: Acoustical Surfaces, n.d.) Figure 2.6: Acoustic Blanket. (Source: All Noise Control, n.d.)
  • 8. 2.3 Existing Design Figure 2.7: Music café reflected ceiling plan – Existing Design. (Source: AE Senior Thesis, n.d.) REVERBERATION TIME SUMMARY: MUSIC CAFÉ (EXISTING) Freq (Hz.) 125 250 500 1000 2000 4000 T60 = 1.677 2.596 0.801 0.798 0.807 0.752 Figure 2.8: Music café reverberation time – Existing Design. (Source: AE Senior Thesis, n.d.) Figures above prove that the existing reverberation times are far-off from the ideal. However, the manufacturer of the metal baffle ceiling system has been omitted from the calculation because it does not have acoustical data for the product. Additional of baffles in the calculation would likely to reduce high reverberation times at lower frequencies and higher frequencies which are already lower than ideal.
  • 9. 2.4 New Design Figure 2.9: Music café reflected ceiling plan – New Design. (Source: AE Senior Thesis, n.d.) REVERBERATION TIME SUMMARY: MUSIC CAFÉ (NEW) Freq (Hz.) 125 250 500 1000 2000 4000 T60 = 1.620 1.243 0.984 1.054 1.077 1.065 Figure 2.10: Music café reverberation time – Existing Design. (Source: AE Senior Thesis, n.d.) BAFFLES – MUSIC CAFE TAG QUANTITY LENGTH (FT) WIDTH (FT) PANEL TYPE A 28 8’-0’’ 2’-6’’ PANEL TYPE B 28 3’-6’’ 2’-6’’ Figure 2.11: Music Café New Baffle Schedule of Materials. (Source: AE Senior Thesis, n.d.) 2.5 Conclusion The new reverberation times are very close to the desired values. According to Architectural Acoustics: Principles and Design finest reverberation times at 125 have to be 1.3 times the ideal reverberation time at 500 hertz and a multiplier of 1.15 should be used at 250 hertz. These multipliers are used to correct for the fact that the human ear is less sensitive at lower frequencies. With these factors included, the new design is very near the target. The new ceiling system will provide superior acoustical performance at a reduced cost.
  • 10. 3.0 RESEARCH METHODOLOGY 3.1 Acoustic Measuring Equipment Figure 3.3: Camera meter. (Source: REED, n.d.) It is used to measure the sound levels at each intersection of gridlines at the site. The readings displayed are in decibel (dB). Figure 3.2: Measuring tape. (Source: REED, n.d.) It is used to find the intersections of grid line on site for data recording. Figure 3.1: Sound level meter. (Source: REED, n.d.) It is used to record materials of furniture and building components used. 3.2 Methodology a) Research on different types of spaces and choose a suitable enclosed space for acoustic study. b) Obtain approval from the owner and conduct visitation to the chosen site. c) Measure and sketch the rough building layout before getting the proper plans from the owner. d) Set gridline at 3m x 3m. e) Distribute tasks among group members. f) Collect data based of proper procedure. g) Observe and record noise sources. h) Tabulate data. i) Carry out calculation and analysis.
  • 11. 3.3 Data Collection Procedure a) Prepare gridlines of 3m x 3m on the floor plan. b) Stand at every intersection of gridlines and hold the device at 1m from the ground. c) Remain silent and record after the reading becomes stable. d) Record the possible sound source at each intersection point. e) Repeat step a to d for another period of time (peak/non-peak). 3.4 Limitation  Environmental factor Due to high sensitivity of sound meter, the reading is very susceptible to surrounding sound, eg: wind and vehicle.  Human error Differences in height levels can affect the reading of sound meter. Also, different manipulators have different height, leading to inaccuracy of result. 3.5 Zonings Zone A is a bar area. It is near the bar counter where the baristas brew coffee and where foods are ordered and paid. It has a total area of 138.39m2 and a total of 20 intersections of gridlines. Zone B is a spacious area used for dining. There are different types and arrangements of furniture. It has a total area of 91.11m2 and a total of 12 intersections of gridlines. Figure 3.4: Plan with zonings.
  • 12. 4.0 ANALYSIS 4.1 Zone A (Bar Area) 4.1.1 Location of Noise Sources Figure 4.1: Identification of noise sources found in the building.
  • 13. Indication Noise Source Specification Units Speaker Product Name Bosch LC2-PC30G6-4 4 Power Handling 50W Frequencies Response 65Hz-20kHz Input Configuration 70V/100V Sound Pressure Level 35-45dB Placement Wall Air-conditioning Product Name Daikin FFR15CV1 4 Total Power 940W Cooling Operation 12500 Btu/hr Sound Pressure Level 38-45 db Placement Ceiling Fan Product Name Panasonic Ceiling Fan PSN- FM15E2 2 Total Power 30W Sound Pressure Level 35-45dB Placement Ceiling Electric Appliances Product Name Mastrena Starbucks Espresso Machine CTS2 801 3 Total Power 800W Sound Pressure Level 82-87 Placement Bar
  • 14. 4.1.2 Material and Properties No. Materials Colour Absorption (Hz) Surface 500 2000 4000 1. Clear epoxy floor finishing Grey 0.01 0.01 0.01 Smooth 2. Concrete wall Grey 0.01 0.02 0.05 Semi- Smooth 3. Concrete Ceiling Grey 0.01 0.02 0.05 Semi- Smooth 4. Concrete blocks wall Light Grey 0.31 0.39 0.25 Rough
  • 15. 5. Glass Transparent 0.03 0.02 0.02 Smooth 6. Stainless steel table top Silver 0.25 0.15 0.15 Smooth 7. Paper drum table (Aluminum top) Silver 0.4 0.43 0.4 Smooth
  • 16. 8. Steel stool Black 0.40 0.43 0.40 Smooth 9. Laminated wood tables and chairs Light Brown 0.15 0.18 0.20 Semi- Smooth 10. Leather cushion Black 0.58 0.58 0.50 Smooth
  • 17. 4.1.3 Sound Meter Reading Figure 4.4: Plan showing sound meter readings during peak period.
  • 18. Figure 4.5: Plan showing sound meter readings during non-peak period.
  • 19. 4.1.4 Sound Intensity Level (SIL) 4.1.4.1 Peak Period Highest readings: 75.9, 76.3, 80.7 𝐼𝑡𝑜𝑡𝑎𝑙 = (3.890 x 10−5 ) + (4.266 x 10−5 ) + (1.175 x 10−5 ) = 9.331 x 10−5 Hence, SIL = 10log ( 𝐼 𝐼𝑜 ) = 10log ( 9.331 𝑥 10 −5 𝐼 𝑥 10−12 ) = 79.70 dB The sound intensity level at Zone A during peak hour is 79.70dB. SIL = 10log ( 𝐼 𝐴 1𝑜 ) 75.9 = 10log ( 𝐼 𝐴 1 𝑥 10−12 ) 7.59 = log ( 𝐼𝐴 1 𝑥 10−12 ) 107.59 = ( 𝐼𝐴 1 𝑥 10−12 ) IA = (1x10−12 ) x (107.59 ) = 3.890 x 10−5 SIL = 10log ( 𝐼 𝐵 1𝑜 ) 76.3 = 10log ( 𝐼 𝐵 1 𝑥 10−12 ) 7.63 = log ( 𝐼 𝐵 1 𝑥 10−12 ) 107.63 = ( 𝐼 𝐵 1 𝑥 10−12 ) IB = (1x10−12 ) x (107.63 ) = 4.266 x 10−5 SIL = 10log ( 𝐼 𝐶 1𝑜 ) 80.7 = 10log ( 𝐼 𝐶 1 𝑥 10−12 ) 8.07 = log ( 𝐼 𝐶 1 𝑥 10−12 ) 108.07 = ( 𝐼 𝐶 1 𝑥 10−12 ) IC = (1x10−12 ) x (108.07 ) = 1.175 x 10−5
  • 20. 4.1.4.2 Non-Peak Period Highest readings: 66.1, 66.9, 66.8 𝐼𝑡𝑜𝑡𝑎𝑙 = (4.074 x 10−6 ) + (4.898 x 10−6 ) + (4.786 x 10−6 ) = 1.376 x 10−5 Hence, SIL = 10log ( 𝐼 𝐼𝑜 ) = 10log ( 1.376 𝑥 10−5 𝐼 𝑥 10−12 ) = 71.39 dB The sound intensity level at Zone A during non-peak hour is 71.39dB. SIL = 10log ( 𝐼 𝐴 1𝑜 ) 66.1 = 10log ( 𝐼𝐴 1 𝑥 10−12 ) 6.61 = log ( 𝐼𝐴 1 𝑥 10−12 ) 106.61 = ( 𝐼𝐴 1 𝑥 10−12 ) IA = (1x10−12 ) x (106.61 ) = 4.074 x 10−6 SIL = 10log ( 𝐼 𝐵 1𝑜 ) 66.9 = 10log ( 𝐼 𝐵 1 𝑥 10−12 ) 6.69 = log ( 𝐼 𝐵 1 𝑥 10−12 ) 106.69 = ( 𝐼 𝐵 1 𝑥 10−12 ) IB = (1x10−12 ) x (106.69 ) = 4.898 x 10−6 SIL = 10log ( 𝐼 𝐶 1𝑜 ) 66.8 = 10log ( 𝐼 𝐶 1 𝑥 10−12 ) 6.68 = log ( 𝐼 𝐶 1 𝑥 10−12 ) 106.68 = ( 𝐼 𝐶 1 𝑥 10−12 ) IC = (1x10−12 ) x (106.68 ) = 4.786 x 10−6
  • 21. 4.1.5 Reverberation Time (RT) Volume of Zone A = 484.36m3 Material absorption coefficient at 500Hz Component Material Surface Area (m2) / Quantity Absorption Coefficient Sound Absorptio n Floor Clear epoxy floor finishing 138.39 0.01 1.38 Wall Concrete blocks wall plaster finish 59.37 0.31 18.40 Exposed concrete blocks 44.45 0.25 11.11 Glass 19.50 0.03 0.59 Ceiling Concrete 57.65 0.01 0.58 Furniture Stainless steel table top 2 0.25 0.50 Paper drum table ( Aluminum) 8 0.40 3.20 Steel stool 24 0.40 9.60 Laminated wood tables 2 0.15 0.30 Occupants 25 0.46 11.50 Total Absorption (A) 57.16 RT = 0.16 𝑥 484 .36 57.16 = 1.36s Material absorption coefficient at 2000Hz Component Material Surface Area (m2) / Quantity Absorption Coefficient Sound Absorption Floor Clear epoxy floor finishing 138.39 0.01 1.38 Wall Concrete blocks wall plaster finish 59.37 0.39 23.15 Exposed concrete blocks 44.45 0.30 13.34 Glass 19.50 0.02 0.39 Ceiling Concrete 57.65 0.02 1.15 Furniture Stainless steel table top 2 0.15 0.30 Paper drum table ( Aluminum) 8 0.43 3.44 Steel stool 24 0.43 10.32 Laminated wood tables 2 0.18 0.36 Occupants 25 0.51 12.75 Total Absorption (A) 66.58 RT = 0.16 𝑥 484 .36 66.58 = 1.16s
  • 22. 4.1.6 Sound Reduction Index (SRI) There is no separation of quiet zone from the open bar, dining and even kitchen area hence no partition wall can be found in the chosen study area. Therefore, a wall that separates the open area and store room will be taken as an example to show the calculation for sound reduction index. Figure 4.6: Elevation of interior wall. Component Surface Area (m2), S Sound Reduction Index, T Transmission Coefficient, T= 1/log-1 (T/10) Concrete Block Wall 25 42 6.310 x 10-5 Wooden Door 2 28 1.585 x 10-3 Tav = (S1T1 + S2T2)/(S1+S2) = [25(6.310 x 10-5) + 2(1.585 x 10-3)]/(25+2) = 1.758 x 10-4 Overall SRI = 10 log (1/ 1.758 x 10-4) = 37.55dB
  • 23. 4.1.7 Photographic observation The café is located in Jalan PJU, the cornerslotnext to the industrial areaandadjacent to residential area, Sunway Rymba Hill, therefore vehicle circulation in front of the site is quite low as the end of the road only consist of high end residence. Human noises are high in the café especially in zone B due to the fact that it is mostly tables filled with customers doing activities such as chit-chatting, laughing and etc. Other than that, there are also noises coming from zone B, the baristas’ area, human noise level is solely based on reception activities and customer from café lounge. Figure 4.7: Mayekawa (M) Sdn Bhd, factory next to Bean Brother. Figure 4.8: Rymba Hill, adjacent to the Bean Brother. Figure: Zone C, social activities happen during peak hour (Source) Figure 4.9: Zone B, social activities happen during peak hour. Figure 4.10: Café lounge in front of the barista area.
  • 24. Speakers are distributed throughout the building for the purpose of playing soft music during opening hour. Figure 4.11: Speakers located at the every possible wall throughout the building. Appliances at the barista such as coffee maker and cooler which generate cool air to keep cakes and dessert fresh produce noise on its own. Furthermore, noises from the open kitchen which produce by the fiction of appliances also contribute certain amount of turbulence and clearly hearable. Ceiling Cassette Unit are found distributed evenly to cover most of the area. They are high in power and produce relatively low noise. Figure 4.12: Café lounge in front of the barista area. Figure 4.13: Barista in the middle of the building. Figure 4.14: Open kitchen.
  • 25. 4.2 Zone B (Dining Area) 4.2.1 Locations of Noise Sources Figure 4.15: Identification of noise sources found in the building. Indication Noise Source Specification Units Speaker Product Name Bosch LC2-PC30G6-4 3 Power Handling 50W Frequencies Response 65Hz-20kHz Input Configuration 70V/100V Sound Pressure Level 35-45dB Placement Wall Air-conditioning Product Name Daikin FFR15CV1 2 Total Power 940W Cooling Operation 12500 Btu/hr Sound Pressure Level 38-45 db Placement Ceiling
  • 26. Fan Product Name Panasonic Ceiling Fan PSN-FM15E2 2 Total Power 155W Sound Pressure Level 35-45dB Placement Ceiling 4.2.2 Material and Properties No. Materials Colour Absorption (Hz) Surface 500 2000 4000 1. Clear epoxy floor finishing Grey 0.01 0.01 0.01 Smooth 2. Concrete wall Grey 0.01 0.02 0.05 Semi- Smooth 3. Concrete Ceiling Grey 0.01 0.02 0.05 Semi- Smooth
  • 27. 4. Concrete blocks wall Light Grey 0.31 0.39 0.25 Rough 5. Glass Transparent 0.03 0.02 0.02 Smooth 6. Stainless steel table top Silver 0.25 0.15 0.15 Smooth 7. Paper drum table (Aluminum top) Silver 0.4 0.43 0.4 Smooth
  • 28. 8. Steel stool Black 0.40 0.43 0.40 Smooth 9. Laminated wood tables and chairs Light Brown 0.15 0.18 0.20 Semi- Smooth 10. Leather cushion Black 0.58 0.58 0.50 Smooth
  • 29. 4.2.2 Sound Meter Reading Figure 4.16: Plan showing sound meter readings during peak period. Figure 4.17: Plan showing sound meter readings during non-peak period.
  • 30. 4.2.3 Sound Intensity Level (SIL) 4.1.3.1 Peak Period Highest readings: 77.2, 76.0, 76.2 𝐼𝑡𝑜𝑡𝑎𝑙 = (5.248 x 10−5 ) + (3.981 x 10−5 ) + (4.169 x 10−5 ) = 1.340 x 10−4 Hence, SIL = 10log ( 𝐼 𝐼𝑜 ) = 10log ( 1.340 𝑥 10−4 𝐼 𝑥 10−12 ) = 81.27 dB The sound intensity level at Zone B during peak hour is 81.27dB. SIL = 10log ( 𝐼 𝐴 1𝑜 ) 77.2 = 10log ( 𝐼 𝐴 1 𝑥 10−12 ) 7.72 = log ( 𝐼𝐴 1 𝑥 10−12 ) 107.72 = ( 𝐼𝐴 1 𝑥 10−12 ) IA = (1x10−12 ) x (107.72 ) = 5.248 x 10−5 SIL = 10log ( 𝐼 𝐵 1𝑜 ) 76.0 = 10log ( 𝐼 𝐵 1 𝑥 10−12 ) 7.60 = log ( 𝐼 𝐵 1 𝑥 10−12 ) 107.60 = ( 𝐼 𝐵 1 𝑥 10−12 ) IB = (1x10−12 ) x (107.60 ) = 3.981 x 10−5 SIL = 10log ( 𝐼 𝐶 1𝑜 ) 76.2 = 10log ( 𝐼 𝐶 1 𝑥 10−12 ) 7.62 = log ( 𝐼 𝐶 1 𝑥 10−12 ) 107.62 = ( 𝐼 𝐶 1 𝑥 10−12 ) IC = (1x10−12 ) x (107.62 ) = 4.169 x 10−5
  • 31. 4.1.3.2 Non-Peak Period Highest readings: 65.3, 66.3, 66.3 𝐼𝑡𝑜𝑡𝑎𝑙 = (3.388 x 10−6 ) + (4.266 x 10−6 ) + (4.266 x 10−6 ) = 1.192 x 10−5 Hence, SIL = 10log ( 𝐼 𝐼𝑜 ) = 10log ( 1.192 𝑥 10 −5 𝐼 𝑥 10−12 ) = 70.76 dB The sound intensity level at Zone B during non-peak hour is 70.76dB. SIL = 10log ( 𝐼 𝐴 1𝑜 ) 65.3 = 10log ( 𝐼𝐴 1 𝑥 10−12 ) 6.53 = log ( 𝐼𝐴 1 𝑥 10−12 ) 106.53 = ( 𝐼𝐴 1 𝑥 10−12 ) IA = (1x10−12 ) x (106.53 ) = 3.388 x 10−6 SIL = 10log ( 𝐼 𝐵 1𝑜 ) 77.2 = 10log ( 𝐼 𝐵 1 𝑥 10−12 ) 7.72 = log ( 𝐼 𝐵 1 𝑥 10−12 ) 107.72 = ( 𝐼 𝐵 1 𝑥 10−12 ) IB = (1x10−12 ) x (107.72 ) = 4.266 x 10−6 SIL = 10log ( 𝐼 𝐶 1𝑜 ) 77.2 = 10log ( 𝐼 𝐶 1 𝑥 10−12 ) 7.72 = log ( 𝐼 𝐶 1 𝑥 10−12 ) 107.72 = ( 𝐼 𝐶 1 𝑥 10−12 ) IC = (1x10−12 ) x (107.72 ) = 4.266 x 10−6
  • 32. 4.2.4 Reverberation Time (RT) Volume of Zone B = 329.38m3 Material absorption coefficient at 500Hz Component Material Surface Area (m2) / Quantity Absorption Coefficient Sound Absorption Floor Clear epoxy floor finishing 94.11 0.01 0.94 Wall Concrete with plaster finish 19.15 0.05 0.96 Concrete blocks wall plaster finish 151.34 0.31 46.92 Exposed concrete blocks 12.32 0.25 3.08 Glass 17.68 0.03 0.53 Ceiling Concrete 89.53 0.01 0.90 Furniture Steel stool 28 0.40 11.20 Laminated wood tables 15 0.15 2.25 Leather cushion 2 0.58 1.16 Occupants 8 0.46 3.68 Total Absorption (A) 71.62 RT = 0.16 𝑥 484 .36 71.62 = 1.08s Material absorption coefficient at 2000Hz Component Material Surface Area (m2) / Quantity Absorption Coefficient Sound Absorption Floor Clear epoxy floor finishing 94.11 0.01 0.94 Wall Concrete with plaster finish 19.15 0.09 1.72 Concrete blocks wall plaster finish 151.34 0.39 59.02 Exposed concrete blocks 12.32 0.30 3.70 Glass 17.68 0.02 0.35 Ceiling Concrete 89.53 0.02 1.79 Furniture Steel stool 28 0.43 12.04 Laminated wood tables 15 0.18 2.70 Leather cushion 2 0.58 1.16 Occupants 8 0.46 3.68 Total Absorption (A) 87.10 RT = 0.16 𝑥 484 .36 87.10 = 0.89s
  • 33. 4.2.6 Photographic observation Speakers are distributed throughout the building for the purpose of playing soft music during opening hour. Figure 4.18: Speakers located throughout the building. Figure 4.19: Café lounge in front of the barista area. Fans are found on the area that are not covered by the air conditioner. Produce certain amount of noises but noises often covered by the noises of human activities and not till extend which will distract and affect the customers nearby.
  • 34. 5.0 CONCLUSION Type of occupancy & activities Recommended reverberation time Coffee bars 45 50 <1.0 Restaurant 45 50 <1.0 Recommended design sound level of a coffee bars and restaurants should be in the average of 45db to 50dB with the recommended time of less than 1.00s by according to AS/ZS 2107:2000 standard for reverberation time and sound levels. Zones Sound Pressure Level (dB) Reverberation Time (s) 500Hz Reverberation Time (s) 2000Hz A 79.70 dB , 71.39dB 1.36s 1.16s B 81.27 dB, 70.76dB 1.08s 0.89s It can be concluded that both two zones did not meet the minimum requirement of the acoustic standard for 500Hz except for zone B which has less than 1.00s reverberation time for 2000Hz. This is due to the selections of material, material that has been used cannot absorb sounds efficiently. From the table above, it is clear that zone B has the highest sound pressure level during peak hours due to the amount of human activities and noise sources of the surrounding. Furthermore, open space concept of the café has also led to the high sound pressure level, for instance, due the open ceiling of the ground floor, noises from the first floor can be transmitted to the ground floor. Satisfactory ySatisfactory Maximum y Satisfactory
  • 35. 6.0 BIBLIOGRAPHY 1. Malaysian Flavor. (2015). Bean Brothers Malaysia @ Sunway Damansara. Retrieved from http://www.malaysianflavours.com/2015/09/bean-brothers-malaysia-sunway- damansara-pj.html 2. Culture District. (N.d). August Wilson Center. Retrieved from https://culturaldistrict.org/pages/awc 3. Pullen. (N.d). Eco Friendly Wood Floor. Retrieved from http://greenliving.lovetoknow.com/Eco_Friendly_Wood_Floor 4. Reed. (N.d). REED C-322 Sound Level Meter/Data Logger, 32 to 130dB. Retrieved from http://www.reedinstruments.com/product/reed-instruments-c-322-sound-level-meter- data-logger 5. AliExpress. (N.d). Acoustic Foam. Retrieved from https://www.aliexpress.com/w/wholesale-acoustic-foam.html 6. Acoustical Surfaces (N.d). Echo Eliminator. Retrieved from http://www.acousticalsurfaces.com/echo_eliminator/ee_hangbaf.htm 7. All Sound Control. (N.d). Outdoor Noise Control Blankets. Retrieved from http://www.allnoisecontrol.com/outdoor-noise-control-blankets.cfm 8. AE Senior Thesis. (N.d). – August Wilson Center. Retrieved from https://www.engr.psu.edu/ae/thesis/portfolios/2008/mpr184/files/final_report/Section 5_Acoustics.pdf