This document is a CV for Darius Rodriguez Angeles, an electrical technician with over 15 years of experience in commissioning, maintenance, and repair of electrical equipment. He has worked on projects in the oil, gas, and power industries in Qatar, Saudi Arabia, and the Philippines. He is proficient in using various electrical testing equipment and follows all necessary safety protocols.
1. CV Darius Rodriguez Angeles Page 1 of 4
Email Add: dariusangeles.06@gmail.com
DARIUS RODRIGUEZ ANGELES
Address: #364 Camachile, Orion Bataan
Contact No.: +63 910 85 49 431
Email Address: dariusangeles.06@gmail.com
CORE QUALIFICATIONS
Can Operate various types of Electrical testing equipment
Technician of Refrigerator & Air conditioning
Good work Ethics
Time Management
Drafting & Painting
Motor control & motors
Driving-with Philippines License
Team player
Resourceful
Industrious & Perseverance
Efficient & accurate
SUMMARY
Detailed-Oriented Instrument technician quickly diagnosed and resolved problem in using manuals, schematics
diagram into various test equipment.
EXPERIENCE
Instrument Technician* May 14, 2014- Nov. 10, 2014
Daemyung Company/Bataan, Philippines
Performed Instrument testing, loop checking, inter cubicle, internal wiring and troubleshooting such as control
valve, valve actuator, level transmitter, temperature transmitter and pressure differential transmitter.
Replaced and Installed instrumentation and equipment per manufacturer specification.
Precisely document services provided to documents and established follow- up communication.
Diagnosed control system problem solving using manual, schematics and various test equipment included
preventive maintenance, field repairs & parts ordering.
SUMMARY
A Competent Electrical Commissioning Technician with overseas experienced in Oil & Gas Industries, Refineries,
LPG, LNG, Power Plant & Onshore construction and Commissioning. Proficient in negotiated w/ clients and
Knowledgeable in Electrical Inspector QA/QC techniques.
Company: Qatar Kentz WLL*June 2005- May 2012
Designation: Commissioning & Electrical Technician
PROJECT HANDLED
A. Electrical Commissioning Technician*April 28, 2010- May 28, 2012
Ras-Gas/ Qatar Kentz WLL Ras Laffan, Qatar
Pre-Commissioning and Commissioning of power distribution, control system panels, lighting, HV/LV cables
including functional test, transformer protection[oil/liquid immerse transformer] buchholz relay, winding
2. CV Darius Rodriguez Angeles Page 2 of 4
Email Add: dariusangeles.06@gmail.com
temperature indicator, oil/liquid temperature indicator as well as oil filled type transformer testing, this includes
oil filtering and condition to meet die-electric breakdown requirement.
Testing and carry out site pre-commissioning/commissioning of electrical equipment rated 33KV,11KV,
6.6KV, 415Volts transformer, switchgear and motors.
Checked Internal/External wiring of every switchgear cubicle from supply AC/DC protection relays, lamps,
signal, switches, earthings protection, current transformer, voltage transformer, motor control circuit and
labeling of switchgear.
Listened & prioritized to attend toolbox meeting to ensure and understand work scope including PTW
requirement.
Evaluated and surveys the quantity of installed electrical equipment and materials.
Commissioning and testing of electrical equipment/system with vendors.
Familiarized w/ lock-out and tag-out procedure.
B. Electrical Commissioning Technician*April 16, 2008- Jan. 06, 2010
WGI/Qatar Gas Ras Laffan, Qatar
Conducted insulation resistance test & inject AC/DC high potential test of electrical equipment like oil immerse
transformer, switchgear contactors, vacuum circuit breaker, bus bar ,bus duct, neutral earthings resistor &
high voltage cable.
Responsible for daily report, preparation and accomplishment of required documents such as checklist/test
sheets records and punch list items and coordinate with client to witness the inspection/testing activities and
obtain approval/signature.
Inter tripping and changed over test of electrical power system and ensure system are properly working.
Testing of medium & low voltage motor by getting winding resistance and insulation resistance test.
Familiarized on various types of testing like hi-pot, insulation resistance test, polarization index test, ratio test,
TTR, polarity test, saturation test, battery discharge test, oil breakdown test, ducter test, MCC & Switchgear
trip test.
Turnover and acceptance of completed facilities system.
Documentation of field related changes.
Team-Oriented, excellent in interpersonal relation and effective interacts w/ electrical engineers and
electricians regarding technical support.
C. Electrical Commissioning Technician*Jan. 27, 2008- April 15, 2008
Fluor/Ras Gas Ras Laffan, Qatar
Confirmed mechanical clearing to start solo run, coupled and uncoupled. Take reading on motor starting
current and motor vibration [vertical & horizontal], bearing temperature, including operational and functional
test on motor control.
Make detailed reports and submit directly to Commissioning Lead.
Interfaced with QA/QC Inspector to settle installation deficiencies and punch list correction.
Installed and repairs lighting, panel boards, glanding and termination of electrical device.
Using Test Equipments such as AC Hipotronic/ VLF hi-pot instrument, OTS 100 AF/2, DLRO 600/ Micro
Ohmmeter, TTR, B10E Programma, SVERKER 760 VANGUARD, DC 16644 Biddle, Megger DET 5/4D/
Earthing test 1605, Megger 830280, FREJA 300, TORKEL 860/TXL 870,Megger AVO Multi-amp and
programma current injector.
D. Lead Electrical Technician*March 29, 2006- Oct. 27, 2007
Dolphine/JGC Ras Laffan, Qatar
Pre- commissioning worked on variable speed drive control panels for air handing units and set up
parameters for variable damper controllers of HVAC ducting system.
Prepared the Inspection test Procedures and Functional test procedure for the building services utilities such
as power system and HVAC control system.
Conducted Loop Impedance test of panel bus bar rated 33KV, 6.6KV, 690V and 415V by injecting primary
current[Oden Programma Equipment Test].
3. CV Darius Rodriguez Angeles Page 3 of 4
Email Add: dariusangeles.06@gmail.com
Reading Blueprints, drawings schematics and Electrical code.
Identified electrical problems like circuit breaker, motor starter and switches.
Evaluate and determined electrical punch list coordination and rectification thereof.
E. Electrical Technician*June 18, 2005- March 28, 2006
Qatar Gas/Qatar Kentz WLL Ras Laffan, Qatar
Good skills, worked as part of team or independently.
Skilled in using Hand tools and Power tools to repair and replaced wiring, equipment and fixture.
Applied pre-commissioning of lighting switches and exhaust fan.
Verified/double check completed activities and ensure that the job performed as per requirement.
SUMMARY
A Capable & hard worked Electrician determined electrical components diagnosis, repairs and Installation with
Plant Operation.
Industrial Electrician*Oct. 26, 2003- Dec. 18, 2004
Saudi Aramco, Saudi Arabia
Supervised and responsible for maintaining diesel generator and welding machine.
Performed glanding and termination of power cables, control cable into switchgear & internal wirings.
Repaired damaged electrical drill, grinder and magnetic contactors.
SUMMARY
Skilled Electrical Maintenance experienced in Combined Cycle Power Plant & A graduate in Bachelor of Science
in Industrial Technology Major in Electrical Technology. Focused and well aware in all color codes, safety
precautions, operating standard practices, expertise in troubleshooting also identification and correction with
electrical components.
Electrical Maintenance*May 15, 2002- June 15, 2003
Alstom Combine Cycle Power Plant Bataan, Philippines
Diagnosed control system problem using manual, schematics and various test equipment.
Maintained preventive maintenance of 2x 300 MW Combine Cycle Power Plant like gas turbine, gas
generator, water/steam cycle and steam turbine, cooling water system and turbine generator, battery
charger, UPS and power battery.
Followed isolation/de-isolation procedure.
Identified corresponding conductors with electrical diagrams and specification to prevent incorrect
connections.
Replaced faulty equipment and components.
Completed paper works on time and accurately.
ON THE JOB TRAINING
Electrical Maintenance*July 03, 2001- Jan. 31, 2002
Alstom Combine Cycle Power Plant Bataan, Philippines
Implement Preventive and Corrective maintenance of machinery and equipments.
Conducted motor rewinding for burned out motors in field as well as overhauling of single phase and three
phase motors.
Skilled in using equipment such as Programma Electric Vibrometer, megger, tachometer, borerouscope,
bearing heater and thermal scanner.
4. CV Darius Rodriguez Angeles Page 4 of 4
Email Add: dariusangeles.06@gmail.com
Technician of Refrigerator & Air conditioning*Nov.18, 1997- Feb. 13, 1998
Bataan Electronics Refrigeration and Air conditioning Bataan, Philippines
Charged Freon in refrigeration & all types of air conditioning.
Installed new motor compressor on defected compressor. It includes rewinding motor, painting of aircon and
refrigerator.
SEMINARS
H2S Gas Training
Permit to Work (PTW)
Safety task Assignment (STA)
Lock-out and Tag-out (LOTO)
Confine Space
Total Safety Task Instruction
Working at Heights
PERSONAL INFORMATION
Birth date: September 06, 1978
Gender: male
Nationality: Filipino
Status: Married
Language: English, Filipino (Tagalog), Arabic
EDUCATION
Bachelor of Science in Science in Industrial Technology major in Electrical Technology
Bataan Polytechnic State College 1998-2002
Vocational
Certificate of Technology for Technician major in Refrigeration and Air Conditioning
Bataan National School of Arts and Trade 1996-1998
CHARACTER REFERENCE
Eladio R. Gales
Electrical Commissioning Team
System Completion Department
COMMON SULFUR PROJECT
QATARGAS II PMT
P.O BOX: 22666
Ras Laffan Industrial City, Qatar
Mobile: +974 5310070
E-mail: EGales@qatar.com.qa