This document contains floor plans for a proposed residential building project called Assisi. The ground floor plan shows a layout with 5 bedrooms, 2 bathrooms, a kitchen, dining area, living area, and utility plant. The first floor plan shows 4 bedrooms, 2 bathrooms, an en suite, dressing area, and gallery. Both plans include notes on ceiling and floor joists, walls, and other structural elements. An outline specification is provided for building materials, windows, doors, finishes, and other components.
2. A
1 2 3 4 5
1 2 3 4 5
B
C
F
A
B
C
F
E E
D D
1
:
Ground Floor Plan
106
01
50
Double pocket door
(2x826)
Double pocket door
(2x826)
(826)
(826)
Double pocket door
(2x826)
(826)
(826)
Guest Room
Bathroom
Utility Plant
Kitchen Family
Dining Living
TV Room
Hall
B-B
B-B
A-A A-A
Beam8overtoS.Eng
Design
Beam 10 over to S.Eng Design
Beam9overtoS.Eng
Design
Floor Joists
to S.Eng Design
Floor Joists
to S.Eng Design
Floor Joists
to S.Eng Design
Floor Joists
to S.Eng Design
Floor Joists
to S.Eng Design
Floor Joists
to S.Eng Design
Floor Joists
to S.Eng Design
4655180018003200
73103670
5005 4920 5005
2700
1115 3835 460 5075 305 675 2935 1340
10790 4950
15740
30528452257951000150010004695
33758990
12365
1452.527101452.51012.524851012.51452.527101452.5
5615 4510 5615
15740
675
516591015659103815
12365
Void over
Rooflight: Internal 1000mm x 3000mm See section B-B
W7
W9
W6
W1
W2
W3
W8
W10
W11
W5
W4
100
Floor Joists
to S.Eng Design
FireplaceTBC
805 1300
(626) (526) (526)
100100100
2900
100
2005
100 100 100
4920
100
5005
100
1045
3800
100
4480
149015001490
974 916 3115
1800
1632 1742 1632
136917421369
1589 1742 1589
103529351035
755916
769916
3974 916
115
262510453355
line of external timber frame walls above
1147.5 2710 1147.5
1217.5 2485.0 1217.5
1147.5 2710 1147.5
810 3835 460 5075
2845390
890
440
SVP
AAV
Gulley
RWP
RWP
RWP RWP
RWP
(726)
210
680910785910
105
Electric
Gas
Water
SVP
SVP
from above
BT
Bespoke staircase and gallery
guarding with frameless glass
guarding designed by specialist
supplier in accordance with
Approved Document K
Beam 5 over to S.Eng
Design
Beam 3 over to S.Eng
Design
Beam 1 over to S.Eng
Design
Beam 2 over to S.Eng
Design
Beam 4 over to S.Eng
Design
Beam 6 over to S.Eng
Design
Beam 7 over to S.Eng
Design
SD
(15l/s)
(15l/s)
(30l/s)
HD
C-C C-C
OUTLINE SPECIFICATION (to be read in accordance with general construction notes)
E1 CONCRETE FOUNDATIONS AND FLOORS
Foundations: Mass concrete trench fill to S.Eng design.
Ground Floor Structure: Proprietary beam and block floor to specialist design.
F1 MASONRY WALLING
Substructure: 7N Thermal/concrete aggregate blockwork as per drawings; 3 courses of
frost resistant brickwork outer skin below DPC or wherever outer skin is exposed above
finished ground levels.
G1 PACKAGED FRAMES AND STRUCTURAL STEELWORK
External Walls: 140x38mm external walls with 11mm OSB sheathing in accordance with
specialist supplier's design. External walls to be pre insulated with 120mm PUR boards.
Notes: Additional insulation to external walls to achieve 0.17W/m²k with additional
25mm PUR foam fixed to external wall panels to be confirmed.
Internal Walls: 38x89mm internal studwork walls with 9mm OSB sheathing. External
walls to achieve 0.22 W/m²k.
Intermediate Floors: Metal web open joists finished with 22mm T&G moisture resistant
chipboard.
Roof Structure: Metal web open joists
G2 STRUCTURAL TIMBER AND GENERAL CARPENTRY
TBC
H2 BOARD AND SHEET EXTERNAL CLADDING AND SOFFITS
Natural Cedar Cladding & Trim: Western Red Cedar Rainscreen cladding profile; Grade 2
Clear & better.
Stone Cladding (Exterior): client to confirm.
Roof Fascia and soffit: client to confirm.
J1 ROOF COVERINGS
Main Pitched Roof: Marley Thrutone fibre cement slate with code 5 lead ridge
Main Flat Roof: Fully adhered single ply membrane in accordance with manufacturer's
instructions to compatible insulation on tsw firrings laid to fall 1in60.
K1 WOOD INTERNAL FLOORING, LININGS AND TRIM
First Floor Generally: Client to confirm
Skirting: Client to confirm
Window Boards: Client to confirm
Other Joinery: Client to confirm
L1 WINDOWS, ROOF WINDOWS AND PATENT GLAZING
Windows: Client to confirm
Glazed Sliding Doors: Client to confirm
Glazed Doors: Client to confirm
L2 DOORS AND FRAMES
Internal Doors: Client to confirm.
Pocket Doors: Client to confirm.
Main External Doors: Client to confirm.
Secondary External Doors: Client to confirm.
L3 STAIRS AND GUARDING
Main Stair: Bespoke staircase designed by specialist supplier.
Balcony Guarding: Frameless glass guarding designed by specialist supplier.
M1 PLASTERING, RENDERING AND SCREEDING
Ground Floor Screed: 50-75mm Gyvlon flowing screed on 150mm PUR insulation
boards.
First Floor Screed: 50-75mm Gyvlon flowing screed on Lewis Deck dovetail sheeting.
Internal Walls: 12.5mm Gyproc plasterboard with plaster skim finish.
Internal Ceilings: Gyproc plasterboard with plaster skim finish.
Coving: Client to confirm.
External Render: Client to confirm.
M4 SHEET AND TILE INTERNAL FINISHES
Ground Floors Generally: Client to confirm.
First Floors Generally: Client to confirm.
First Floors to Bathrooms: Client to confirm.
Tiled walls to Bathrooms: Client to confirm.
Other: Client to confirm.
M6 PAINTING, STAINING AND VARNISHING
Walls & Ceilings Generally: Dulux 3 coat paint system, Trade Vinyl Matt Colour: White.
Bathrooms: Dulux 3 coat paint system, Trade Diamond Matt Colour: White.
Skirting and Window Boards: Dulux 3 coat paint system - Trade Satinwood: White
N1 APPLIANCES AND FITTINGS
Kitchen: Refer to kitchen designers plan.
Bathrooms: Refer to Bathroom designer plan.
Living Room Fireplace: Client to confirm.
Family Room: Client to confirm.
Q1 HARD LANDSCAPING
Designed by others.
TONY HOLT DESIGN.
Bespoke Property Designer
Bournemouth:
Website:
Email:
01202 208331
info@tonyholt-design.co.uk
www.tonyholt-design.co.uk
project name
rev
dwg sheet
dwg no
dwg name
DISCUSSION
Assisi
Proposed Ground Floor Plan
106
A1@ 1:50
R2 - 22.10.2016
PRELIMINARY
IMPORTANT NOTE
All dimensions in millimeters . Where dimensions are not given, drawings must not be
scaled. In the event of any detail or dimensional conflict between drawings and site
conditions, the matter must be referred back to the author for clarification. All
dimensions and conditions are to be checked on site by the contractor prior to
commencing any work. The contractor is responsible for checking that there is no
conflict between site dimensions and figured dimensions. Drawings to be read in
conjunction with Structural Engineer's, Mechanical and Electrical Engineer's, Specialist
Manufacturer's and Sub-contractor's drawings and specification.
3. 1800
100
2600
LoftAccess
B-B
B-B
A-A A-A
A
1 2 3 4 5
1 2 3 4 5
B
C
F
A
B
C
F
E E
D D
(826)
(826)
(826)
(826)
(826)
Pocket door
(826)
Bedroom 3
Bedroom 4
Master
Bedroom
Bathroom
En Suite
Bedroom 2
Dressing
En Suite
Gallery
1
:
First Floor Plan
107
01
50
Ceiling Joists
to S.Eng Design
Ceiling Joists
to S.Eng Design
CeilingJoists
toS.EngDesign
Ceiling Joists
to S.Eng Design
Flat Roof Joists
to S.Eng Design
Rafters
to S.Eng Design
Rafters
to S.Eng Design
Rafters
to S.Eng Design
Rafters
to S.Eng Design
Rafters
to S.Eng Design
Rafters
to S.Eng Design
Rafters
to S.Eng Design
Rafters
to S.Eng Design
Rafters
toS.EngDesign
Vaulted
Ceiling
Line of bulkhead
Line of bulkhead
Line of bulkhead
Lineofbulkhead
Vaulted Ceiling
Vaulted Ceiling
Vaulted Ceiling
Post
Post
Post
Post
2mheightline2mheightline
2mheightline2mheightline
2mheightline2mheightline
Covered
Terrace
Frameless glass guarding designed
and installed by Specialist
Subcontractor in accordance with
Approved Document K and BS6180.
1440 2935 1440 800 2710 800 1115 325 2935 1440
5815 10125
15940
1482260021139103210
10315
2145
1125
940
1552.527101552.5912.51552.527101552.5
5815 4310 5815
15940
4435125012159103630
11440
5270 4920 4950
3500
1670
528516202930
W17
W18 W19
W14
W13
W12
W20
W21
W16
W15
3100100
5895
2mheightline2mheightline
1:60 Falls
1:60 Falls
912.5 2485
(826)
2375
W22
LoftAccess
3280915
100
1250435
100
680910
210
100
3180
100
100
4920
100
5270
5535
5535 5535
2935 13001035
100100
2452 2718
1336 916 3018
630
3849
155
916
3580
750
3100
100
10199163960
8402090
8404025
215
916
539
16703600
769916
115
1334916
350
539
916
215
945
3600
10253200
1105 2710 1105
100
100
1300 2935 1300
440
890
Post
Post
Post
Post
Rooflight: Internal 1000mm x 3000mm See section B-B
SVP
SVP
RWP
RWP
RWP
RWP RWP
RWP
RWP630
Pocket door
(826)
630
2350
Overlineflatroofabove
Outlineflatroofabove
SVP
Bespoke staircase and gallery
guarding with frameless glass
guarding designed by specialist
supplier in accordance with
Approved Document K
(15l/s)
(15l/s)
(15l/s)
SD
C-C C-C
DORMERCEILINGLINE
FLATCEILINGLINE
OUTLINE SPECIFICATION (to be read in accordance with general construction notes)
E1 CONCRETE FOUNDATIONS AND FLOORS
Foundations: Mass concrete trench fill to S.Eng design.
Ground Floor Structure: Proprietary beam and block floor to specialist design.
F1 MASONRY WALLING
Substructure: 7N Thermal/concrete aggregate blockwork as per drawings; 3 courses of
frost resistant brickwork outer skin below DPC or wherever outer skin is exposed above
finished ground levels.
G1 PACKAGED FRAMES AND STRUCTURAL STEELWORK
External Walls: 140x38mm external walls with 11mm OSB sheathing in accordance with
specialist supplier's design. External walls to be pre insulated with 120mm PUR boards.
Notes: Additional insulation to external walls to achieve 0.17W/m²k with additional
25mm PUR foam fixed to external wall panels to be confirmed.
Internal Walls: 38x89mm internal studwork walls with 9mm OSB sheathing. External
walls to achieve 0.22 W/m²k.
Intermediate Floors: Metal web open joists finished with 22mm T&G moisture resistant
chipboard.
Roof Structure: Metal web open joists
G2 STRUCTURAL TIMBER AND GENERAL CARPENTRY
TBC
H2 BOARD AND SHEET EXTERNAL CLADDING AND SOFFITS
Natural Cedar Cladding & Trim: Western Red Cedar Rainscreen cladding profile; Grade 2
Clear & better.
Stone Cladding (Exterior): client to confirm.
Roof Fascia and soffit: client to confirm.
J1 ROOF COVERINGS
Main Pitched Roof: Marley Thrutone fibre cement slate with code 5 lead ridge
Main Flat Roof: Fully adhered single ply membrane in accordance with manufacturer's
instructions to compatible insulation on tsw firrings laid to fall 1in60.
K1 WOOD INTERNAL FLOORING, LININGS AND TRIM
First Floor Generally: Client to confirm
Skirting: Client to confirm
Window Boards: Client to confirm
Other Joinery: Client to confirm
L1 WINDOWS, ROOF WINDOWS AND PATENT GLAZING
Windows: Client to confirm
Glazed Sliding Doors: Client to confirm
Glazed Doors: Client to confirm
L2 DOORS AND FRAMES
Internal Doors: Client to confirm.
Pocket Doors: Client to confirm.
Main External Doors: Client to confirm.
Secondary External Doors: Client to confirm.
L3 STAIRS AND GUARDING
Main Stair: Bespoke staircase designed by specialist supplier.
Balcony Guarding: Frameless glass guarding designed by specialist supplier.
M1 PLASTERING, RENDERING AND SCREEDING
Ground Floor Screed: 50-75mm Gyvlon flowing screed on 150mm PUR insulation
boards.
First Floor Screed: 50-75mm Gyvlon flowing screed on Lewis Deck dovetail sheeting.
Internal Walls: 12.5mm Gyproc plasterboard with plaster skim finish.
Internal Ceilings: Gyproc plasterboard with plaster skim finish.
Coving: Client to confirm.
External Render: Client to confirm.
M4 SHEET AND TILE INTERNAL FINISHES
Ground Floors Generally: Client to confirm.
First Floors Generally: Client to confirm.
First Floors to Bathrooms: Client to confirm.
Tiled walls to Bathrooms: Client to confirm.
Other: Client to confirm.
M6 PAINTING, STAINING AND VARNISHING
Walls & Ceilings Generally: Dulux 3 coat paint system, Trade Vinyl Matt Colour: White.
Bathrooms: Dulux 3 coat paint system, Trade Diamond Matt Colour: White.
Skirting and Window Boards: Dulux 3 coat paint system - Trade Satinwood: White
N1 APPLIANCES AND FITTINGS
Kitchen: Refer to kitchen designers plan.
Bathrooms: Refer to Bathroom designer plan.
Living Room Fireplace: Client to confirm.
Family Room: Client to confirm.
Q1 HARD LANDSCAPING
Designed by others.
TONY HOLT DESIGN.
Bespoke Property Designer
Bournemouth:
Website:
Email:
01202 208331
info@tonyholt-design.co.uk
www.tonyholt-design.co.uk
project name
rev
dwg sheet
dwg no
dwg name
DISCUSSION
Assisi
Proposed First Floor Plan
107
A1@ 1:50
R2 - 22.10.2016
PRELIMINARY
IMPORTANT NOTE
All dimensions in millimeters . Where dimensions are not given, drawings must not be
scaled. In the event of any detail or dimensional conflict between drawings and site
conditions, the matter must be referred back to the author for clarification. All
dimensions and conditions are to be checked on site by the contractor prior to
commencing any work. The contractor is responsible for checking that there is no
conflict between site dimensions and figured dimensions. Drawings to be read in
conjunction with Structural Engineer's, Mechanical and Electrical Engineer's, Specialist
Manufacturer's and Sub-contractor's drawings and specification.
4. ABF E D C
ABF E D C
1
:
East Elevation
110
01
50
W20 W21
W8 W10 W11
PowderCoatedAluminumColumnCasement
Timber Cladding
Slate Tiling
Timber Cladding
Natural
Stone
Cladding
Natural
Stone
Cladding
Natural
Stone
Cladding
Frameless glass guarding designed
and installed by Specialist
Subcontractor in accordance with
Approved Document K and BS6180.
Window Head
2.100
top of wall
plate
4.620
Ground
Level
- 0.150
DPC
0.000
Window Head
4.981
top of floor
joist 2.775
top of screed
level
2.881
top of
ridge beam
7.737
u/s flat roof
joists
6.970
u/s of floor
joist
2.521
Render
1100
12345
12345
1
:
North Elevation
110
02
50
W12.1
W12.2
W1
'e'
W13
W14.1
W14.2
'e'
W3
'e'
W2
Slate Tiling
Timber Cladding
Timber Cladding
Powder Coated Aluminum Beam Casement
Powder Coated Aluminum CladdingPowder Coated Aluminum Cladding
Powder Coated Aluminum Canopy
PowderCoated
Alum
inum
Beam
Casem
entPowderCoated
Alum
inum
Beam
Casem
ent
Code 4 Lead Flashing
1100
Powder Coated Aluminum Beam Casement
PowderCoated
Alum
inum
Beam
Casem
entPowderCoated
Alum
inum
Beam
Casem
ent
Natural
Stone
Cladding
Natural
Stone
Cladding
Render
Window Head
2.100
top of wall
plate
4.620
Ground
Level
- 0.150
DPC
0.000
Window Head
4.981
top of floor
joist 2.775
top of screed
level
2.881
top of
ridge beam
7.737
u/s flat roof
joists
6.970
u/s of floor
joist
2.521
Render
Render
Render
Render Render
800
OUTLINE SPECIFICATION (to be read in accordance with general construction notes)
E1 CONCRETE FOUNDATIONS AND FLOORS
Foundations: Mass concrete trench fill to S.Eng design.
Ground Floor Structure: Proprietary beam and block floor to specialist design.
F1 MASONRY WALLING
Substructure: 7N Thermal/concrete aggregate blockwork as per drawings; 3 courses of
frost resistant brickwork outer skin below DPC or wherever outer skin is exposed above
finished ground levels.
G1 PACKAGED FRAMES AND STRUCTURAL STEELWORK
External Walls: 140x38mm external walls with 11mm OSB sheathing in accordance with
specialist supplier's design. External walls to be pre insulated with 120mm PUR boards.
Notes: Additional insulation to external walls to achieve 0.17W/m²k with additional
25mm PUR foam fixed to external wall panels to be confirmed.
Internal Walls: 38x89mm internal studwork walls with 9mm OSB sheathing. External
walls to achieve 0.22 W/m²k.
Intermediate Floors: Metal web open joists finished with 22mm T&G moisture resistant
chipboard.
Roof Structure: Metal web open joists
G2 STRUCTURAL TIMBER AND GENERAL CARPENTRY
TBC
H2 BOARD AND SHEET EXTERNAL CLADDING AND SOFFITS
Natural Cedar Cladding & Trim: Western Red Cedar Rainscreen cladding profile; Grade 2
Clear & better.
Stone Cladding (Exterior): client to confirm.
Roof Fascia and soffit: client to confirm.
J1 ROOF COVERINGS
Main Pitched Roof: Marley Thrutone fibre cement slate with code 5 lead ridge
Main Flat Roof: Fully adhered single ply membrane in accordance with manufacturer's
instructions to compatible insulation on tsw firrings laid to fall 1in60.
K1 WOOD INTERNAL FLOORING, LININGS AND TRIM
First Floor Generally: Client to confirm
Skirting: Client to confirm
Window Boards: Client to confirm
Other Joinery: Client to confirm
L1 WINDOWS, ROOF WINDOWS AND PATENT GLAZING
Windows: Client to confirm
Glazed Sliding Doors: Client to confirm
Glazed Doors: Client to confirm
L2 DOORS AND FRAMES
Internal Doors: Client to confirm.
Pocket Doors: Client to confirm.
Main External Doors: Client to confirm.
Secondary External Doors: Client to confirm.
L3 STAIRS AND GUARDING
Main Stair: Bespoke staircase designed by specialist supplier.
Balcony Guarding: Frameless glass guarding designed by specialist supplier.
M1 PLASTERING, RENDERING AND SCREEDING
Ground Floor Screed: 50-75mm Gyvlon flowing screed on 150mm PUR insulation
boards.
First Floor Screed: 50-75mm Gyvlon flowing screed on Lewis Deck dovetail sheeting.
Internal Walls: 12.5mm Gyproc plasterboard with plaster skim finish.
Internal Ceilings: Gyproc plasterboard with plaster skim finish.
Coving: Client to confirm.
External Render: Client to confirm.
M4 SHEET AND TILE INTERNAL FINISHES
Ground Floors Generally: Client to confirm.
First Floors Generally: Client to confirm.
First Floors to Bathrooms: Client to confirm.
Tiled walls to Bathrooms: Client to confirm.
Other: Client to confirm.
M6 PAINTING, STAINING AND VARNISHING
Walls & Ceilings Generally: Dulux 3 coat paint system, Trade Vinyl Matt Colour: White.
Bathrooms: Dulux 3 coat paint system, Trade Diamond Matt Colour: White.
Skirting and Window Boards: Dulux 3 coat paint system - Trade Satinwood: White
N1 APPLIANCES AND FITTINGS
Kitchen: Refer to kitchen designers plan.
Bathrooms: Refer to Bathroom designer plan.
Living Room Fireplace: Client to confirm.
Family Room: Client to confirm.
Q1 HARD LANDSCAPING
Designed by others.
TONY HOLT DESIGN.
Bespoke Property Designer
Bournemouth:
Website:
Email:
01202 208331
info@tonyholt-design.co.uk
www.tonyholt-design.co.uk
project name
rev
dwg sheet
dwg no
dwg name
DISCUSSION
Assisi
Proposed East and North Elevation
110
A1@ 1:50
R2 - 22.10.2016
PRELIMINARY
IMPORTANT NOTE
All dimensions in millimeters . Where dimensions are not given, drawings must not be
scaled. In the event of any detail or dimensional conflict between drawings and site
conditions, the matter must be referred back to the author for clarification. All
dimensions and conditions are to be checked on site by the contractor prior to
commencing any work. The contractor is responsible for checking that there is no
conflict between site dimensions and figured dimensions. Drawings to be read in
conjunction with Structural Engineer's, Mechanical and Electrical Engineer's, Specialist
Manufacturer's and Sub-contractor's drawings and specification.
5. A B FEDC
A B FEDC
1
:
West Elevation
111
01
50
W15
obscure
glazing
W4
W5
Slate Tiling
Timber Cladding
Natural
Stone
Cladding
NaturalStoneCladding
Timber
Cladding
W16
obscure
glazing
Window Head
2.100
top of wall
plate
4.620
Ground
Level
- 0.150
DPC
0.000
Window Head
4.981
top of floor
joist 2.775
top of screed
level
2.881
top of
ridge beam
7.737
u/s flat roof
joists
6.970
u/s of floor
joist
2.521
Render Render
1100
'e'
W17.1
W17.2
1 2 3 4 5
1 2 3 4 5
1
:
South Elevation
111
02
50
W18
'e'
'e'
W19.1
W19.2
W6 W7 W9
Slate Tiling
Timber Cladding
Timber
Cladding
Powder Coated Aluminum Beam Casement
PowderCoated
Alum
inum
Beam
Casem
entPowderCoated
Alum
inum
Beam
Casem
ent
Powder Coated Aluminum Beam Casement
PowderCoated
Alum
inum
Beam
Casem
entPowderCoated
Alum
inum
Beam
Casem
ent
Powder Coated Aluminum Beam Casement
PowderCoatedAluminumColumnCasement
PowderCoatedAluminumColumnCasement
Natural
Stone
Cladding
Timber
Cladding
Render
Render
Natural
Stone
Cladding
Natural
Stone
Cladding
RenderRender
1100
Frameless glass guarding designed
and installed by Specialist
Subcontractor in accordance with
Approved Document K and BS6180.
800
OUTLINE SPECIFICATION (to be read in accordance with general construction notes)
E1 CONCRETE FOUNDATIONS AND FLOORS
Foundations: Mass concrete trench fill to S.Eng design.
Ground Floor Structure: Proprietary beam and block floor to specialist design.
F1 MASONRY WALLING
Substructure: 7N Thermal/concrete aggregate blockwork as per drawings; 3 courses of
frost resistant brickwork outer skin below DPC or wherever outer skin is exposed above
finished ground levels.
G1 PACKAGED FRAMES AND STRUCTURAL STEELWORK
External Walls: 140x38mm external walls with 11mm OSB sheathing in accordance with
specialist supplier's design. External walls to be pre insulated with 120mm PUR boards.
Notes: Additional insulation to external walls to achieve 0.17W/m²k with additional
25mm PUR foam fixed to external wall panels to be confirmed.
Internal Walls: 38x89mm internal studwork walls with 9mm OSB sheathing. External
walls to achieve 0.22 W/m²k.
Intermediate Floors: Metal web open joists finished with 22mm T&G moisture resistant
chipboard.
Roof Structure: Metal web open joists
G2 STRUCTURAL TIMBER AND GENERAL CARPENTRY
TBC
H2 BOARD AND SHEET EXTERNAL CLADDING AND SOFFITS
Natural Cedar Cladding & Trim: Western Red Cedar Rainscreen cladding profile; Grade 2
Clear & better.
Stone Cladding (Exterior): client to confirm.
Roof Fascia and soffit: client to confirm.
J1 ROOF COVERINGS
Main Pitched Roof: Marley Thrutone fibre cement slate with code 5 lead ridge
Main Flat Roof: Fully adhered single ply membrane in accordance with manufacturer's
instructions to compatible insulation on tsw firrings laid to fall 1in60.
K1 WOOD INTERNAL FLOORING, LININGS AND TRIM
First Floor Generally: Client to confirm
Skirting: Client to confirm
Window Boards: Client to confirm
Other Joinery: Client to confirm
L1 WINDOWS, ROOF WINDOWS AND PATENT GLAZING
Windows: Client to confirm
Glazed Sliding Doors: Client to confirm
Glazed Doors: Client to confirm
L2 DOORS AND FRAMES
Internal Doors: Client to confirm.
Pocket Doors: Client to confirm.
Main External Doors: Client to confirm.
Secondary External Doors: Client to confirm.
L3 STAIRS AND GUARDING
Main Stair: Bespoke staircase designed by specialist supplier.
Balcony Guarding: Frameless glass guarding designed by specialist supplier.
M1 PLASTERING, RENDERING AND SCREEDING
Ground Floor Screed: 50-75mm Gyvlon flowing screed on 150mm PUR insulation
boards.
First Floor Screed: 50-75mm Gyvlon flowing screed on Lewis Deck dovetail sheeting.
Internal Walls: 12.5mm Gyproc plasterboard with plaster skim finish.
Internal Ceilings: Gyproc plasterboard with plaster skim finish.
Coving: Client to confirm.
External Render: Client to confirm.
M4 SHEET AND TILE INTERNAL FINISHES
Ground Floors Generally: Client to confirm.
First Floors Generally: Client to confirm.
First Floors to Bathrooms: Client to confirm.
Tiled walls to Bathrooms: Client to confirm.
Other: Client to confirm.
M6 PAINTING, STAINING AND VARNISHING
Walls & Ceilings Generally: Dulux 3 coat paint system, Trade Vinyl Matt Colour: White.
Bathrooms: Dulux 3 coat paint system, Trade Diamond Matt Colour: White.
Skirting and Window Boards: Dulux 3 coat paint system - Trade Satinwood: White
N1 APPLIANCES AND FITTINGS
Kitchen: Refer to kitchen designers plan.
Bathrooms: Refer to Bathroom designer plan.
Living Room Fireplace: Client to confirm.
Family Room: Client to confirm.
Q1 HARD LANDSCAPING
Designed by others.
TONY HOLT DESIGN.
Bespoke Property Designer
Bournemouth:
Website:
Email:
01202 208331
info@tonyholt-design.co.uk
www.tonyholt-design.co.uk
project name
rev
dwg sheet
dwg no
dwg name
DISCUSSION
Assisi
Proposed West and South Elevation
111
A1@ 1:50
R2 - 22/10/2016
PRELIMINARY
IMPORTANT NOTE
All dimensions in millimeters . Where dimensions are not given, drawings must not be
scaled. In the event of any detail or dimensional conflict between drawings and site
conditions, the matter must be referred back to the author for clarification. All
dimensions and conditions are to be checked on site by the contractor prior to
commencing any work. The contractor is responsible for checking that there is no
conflict between site dimensions and figured dimensions. Drawings to be read in
conjunction with Structural Engineer's, Mechanical and Electrical Engineer's, Specialist
Manufacturer's and Sub-contractor's drawings and specification.
6. Beam & Block Floor
Void min 150mm
Beam & Block Floor
Void min 150mm
TV Room Guest Room
En Suite Bedroom 2
47.5°
1
:
Section A-A
120
01
50
12345
Window Head
2.100
top of wall
plate
4.620
Ground
Level
- 0.150
DPC
0.000
Window Head
4.981
top of floor
joist 2.775
top of screed
level
2.881
top of
ridge beam
7.737
u/s flat roof
joists
6.970
u/s of floor
joist
2.521
2807.5 2807.52807.5 2807.5
CLofGrid
lines3&
CLofGrid
lines1&
A B FEDC
A B FEDC
Void min 150mm
Family
Hall Dining
Gallery
Bedroom 4
1
:
Section B-B
120
02
50
u/s flat roof
joists
5.306
Beam & Block Floor
Window Head
2.100
top of wall
plate
4.620
Ground
Level
- 0.150
DPC
0.000
Window Head
4.981
top of floor
joist 2.775
top of screed
level
2.881
top of
ridge beam
7.737
u/s flat roof
joists
6.970
u/s of floor
joist
2.521
Bespoke staircase and gallery
guarding with frameless glass
guarding designed by specialist
supplier in accordance with
Approved Document K
OUTLINE SPECIFICATION (to be read in accordance with general construction notes)
E1 CONCRETE FOUNDATIONS AND FLOORS
Foundations: Mass concrete trench fill to S.Eng design.
Ground Floor Structure: Proprietary beam and block floor to specialist design.
F1 MASONRY WALLING
Substructure: 7N Thermal/concrete aggregate blockwork as per drawings; 3 courses of
frost resistant brickwork outer skin below DPC or wherever outer skin is exposed above
finished ground levels.
G1 PACKAGED FRAMES AND STRUCTURAL STEELWORK
External Walls: 140x38mm external walls with 11mm OSB sheathing in accordance with
specialist supplier's design. External walls to be pre insulated with 120mm PUR boards.
Notes: Additional insulation to external walls to achieve 0.17W/m²k with additional
25mm PUR foam fixed to external wall panels to be confirmed.
Internal Walls: 38x89mm internal studwork walls with 9mm OSB sheathing. External
walls to achieve 0.22 W/m²k.
Intermediate Floors: Metal web open joists finished with 22mm T&G moisture resistant
chipboard.
Roof Structure: Metal web open joists
G2 STRUCTURAL TIMBER AND GENERAL CARPENTRY
TBC
H2 BOARD AND SHEET EXTERNAL CLADDING AND SOFFITS
Natural Cedar Cladding & Trim: Western Red Cedar Rainscreen cladding profile; Grade 2
Clear & better.
Stone Cladding (Exterior): client to confirm.
Roof Fascia and soffit: client to confirm.
J1 ROOF COVERINGS
Main Pitched Roof: Marley Thrutone fibre cement slate with code 5 lead ridge
Main Flat Roof: Fully adhered single ply membrane in accordance with manufacturer's
instructions to compatible insulation on tsw firrings laid to fall 1in60.
K1 WOOD INTERNAL FLOORING, LININGS AND TRIM
First Floor Generally: Client to confirm
Skirting: Client to confirm
Window Boards: Client to confirm
Other Joinery: Client to confirm
L1 WINDOWS, ROOF WINDOWS AND PATENT GLAZING
Windows: Client to confirm
Glazed Sliding Doors: Client to confirm
Glazed Doors: Client to confirm
L2 DOORS AND FRAMES
Internal Doors: Client to confirm.
Pocket Doors: Client to confirm.
Main External Doors: Client to confirm.
Secondary External Doors: Client to confirm.
L3 STAIRS AND GUARDING
Main Stair: Bespoke staircase designed by specialist supplier.
Balcony Guarding: Frameless glass guarding designed by specialist supplier.
M1 PLASTERING, RENDERING AND SCREEDING
Ground Floor Screed: 50-75mm Gyvlon flowing screed on 150mm PUR insulation
boards.
First Floor Screed: 50-75mm Gyvlon flowing screed on Lewis Deck dovetail sheeting.
Internal Walls: 12.5mm Gyproc plasterboard with plaster skim finish.
Internal Ceilings: Gyproc plasterboard with plaster skim finish.
Coving: Client to confirm.
External Render: Client to confirm.
M4 SHEET AND TILE INTERNAL FINISHES
Ground Floors Generally: Client to confirm.
First Floors Generally: Client to confirm.
First Floors to Bathrooms: Client to confirm.
Tiled walls to Bathrooms: Client to confirm.
Other: Client to confirm.
M6 PAINTING, STAINING AND VARNISHING
Walls & Ceilings Generally: Dulux 3 coat paint system, Trade Vinyl Matt Colour: White.
Bathrooms: Dulux 3 coat paint system, Trade Diamond Matt Colour: White.
Skirting and Window Boards: Dulux 3 coat paint system - Trade Satinwood: White
N1 APPLIANCES AND FITTINGS
Kitchen: Refer to kitchen designers plan.
Bathrooms: Refer to Bathroom designer plan.
Living Room Fireplace: Client to confirm.
Family Room: Client to confirm.
Q1 HARD LANDSCAPING
Designed by others.
Beam & Block Floor
LIVING ROOM
MASTER BEDROOM
1
:
Section C-C
120
01
50
345
345
Window Head
2.100
top of wall
plate
4.620
Ground
Level
- 0.150
DPC
0.000
Window Head
4.981
top of floor
joist 2.775
top of screed
level
2.881
top of
ridge beam
7.737
u/s flat roof
joists
6.970
u/s of floor
joist
2.521
2807.5 2807.5
CLofGride
lines3&5
Void min 150mm
2425
2425
2521
TONY HOLT DESIGN.
Bespoke Property Designer
Bournemouth:
Website:
Email:
01202 208331
info@tonyholt-design.co.uk
www.tonyholt-design.co.uk
project name
rev
dwg sheet
dwg no
dwg name
DISCUSSION
Assisi
Proposed Section A
120
A1@ 1:50
R2 - 22.10.2016
PRELIMINARY
IMPORTANT NOTE
All dimensions in millimeters . Where dimensions are not given, drawings must not be
scaled. In the event of any detail or dimensional conflict between drawings and site
conditions, the matter must be referred back to the author for clarification. All
dimensions and conditions are to be checked on site by the contractor prior to
commencing any work. The contractor is responsible for checking that there is no
conflict between site dimensions and figured dimensions. Drawings to be read in
conjunction with Structural Engineer's, Mechanical and Electrical Engineer's, Specialist
Manufacturer's and Sub-contractor's drawings and specification.