Sheet 1

393 views
235 views

Published on

Published in: Design
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
393
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
4
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Sheet 1

  1. 1. SINGLE LINE DIAGRAM LEGEND: CIRCUIT CONNECTION SWITCH CONNECTION FROM POWER SOURCE M M 2-600 MCM AWG METER CONVENIENCE OUTLET SPECIAL PURPOSE OUTLET S# 450 AT SWITCH COMPACT FLUORESCENT LAMP 2-80 MM2 TW - COPPER WIRE 2-80 MM2 TW - COPPER WIRE # 2-80 MM2 TW - COPPER WIRE CIRCUIT BREAKER SERVICE ENTRANCE M KILOWATT HOUR METER M KILOWATT HOUR METER M KILOWATT HOUR METER MAIN DISTRIBUTION PANEL GENERAL NOTES: SCHEDULE OF LOADS TYPE OF SERVICE ; 230 V , 2-WIRE , 60 HZ , S INGLE PHASE CKT. NO. 1 30AT 175 AT 30AT 2 1 30AT 30AT 2 22 LOAD DESCRIPTION QTY. WATTS AMP. CKT. BRANCH PROTECTION SIZE OF COPPER WIRE CONVENIENCE OUTLET 10 3600 15.65 30A CIRCUIT BREAKER 2 - 3.50 MM2 TW WIRE 13 MM ELECTRIC CONDUIT CONVENIENCE OUTLET 6 3240 14.09 30A CIRCUIT BREAKER 2 - 3.50 MM2 TW WIRE 13 MM ELECTRIC CONDUIT 3 70 AT 1 2 175 AT CONVENIENCE OUTLET 7 2520 10.96 30A CIRCUIT BREAKER 2 - 3.50 MM2 TW WIRE 13 MM ELECTRIC CONDUIT SIZE OF CONDUIT 30AT 30AT 4 3 30AT 30AT 4 4 CONVENIENCE OUTLET 10 3600 15.65 30A CIRCUIT BREAKER 2 - 3.50 MM2 TW WIRE 13 MM ELECTRIC CONDUIT 5 CONVENIENCE OUTLET 10 3600 15.65 30A CIRCUIT BREAKER 2 - 3.50 MM2 TW WIRE 13 MM ELECTRIC CONDUIT 6 3 LAUNDRY UNIT 1 1500 5.22 30A CIRCUIT BREAKER 2 - 3.50 MM2 TW WIRE 13 MM 30AT 6 5 30AT 30AT 6 ELECTRIC CONDUIT 7 60AT 60AT 8 7 60AT 60AT 8 9 70AT 70AT 10 9 70AT 70AT 10 7 AIRCON UNIT 1 1865 8.11 60A CIRCUIT BREAKER 20 MM ELECTRIC CONDUIT AIRCON UNIT 1 1865 8.11 60A CIRCUIT BREAKER 2 - 5.50 MM2 TW WIRE 20 MM ELECTRIC CONDUIT 9 AIRCON UNIT 1 2238 9.73 70A CIRCUIT BREAKER 2 - 8.00 MM2 TW WIRE 30 MM ELECTRIC CONDUIT 10 30AT 2 - 5.50 MM2 TW WIRE 8 5 AIRCON UNIT 1 2238 9.73 70A CIRCUIT BREAKER 2 - 8.00 MM2 TW WIRE 30 MM ELECTRIC CONDUIT 11 AIRCON UNIT 1 2238 9.73 70A CIRCUIT BREAKER 2 - 8.00 MM2 TW WIRE 30 MM ELECTRIC CONDUIT AIRCON UNIT 1 70A CIRCUIT BREAKER 2 - 8.00 MM2 TW WIRE 12 15 15AT 15AT 17 15AT 15AT 19 15AT 15AT 14 11 13 70AT 70AT 15AT 30AT 16 15 15AT 15AT 18 17 15AT 15AT 20 19 15AT 15AT 12 14 16 18 20 2238 9.73 1 5100 17.74 30A CIRCUIT BREAKER 2 - 5.50 MM2 TW WIRE 20 MM 1100 4.78 15A CIRCUIT BREAKER 2 - 2.00 MM2 TW WIRE 13 MM 15 LIGHTING OUTLET 8 800 3.48 15A CIRCUIT BREAKER 2 - 2.00 MM2 TW WIRE 13 MM ELECTRIC CONDUIT LIGHTING OUTLET 8 800 3.48 15A CIRCUIT BREAKER 2 - 2.00 MM2 TW WIRE 13 MM ELECTRIC CONDUIT 17 LIGHTING OUTLET 9 900 3.91 15A CIRCUIT BREAKER 2 - 2.00 MM2 TW ` WIRE 13 MM ELECTRIC CONDUIT LIGHTING OUTLET 10 1000 4.35 15A CIRCUIT BREAKER 2 - 2.00 MM2 TW WIRE 13 MM ELECTRIC CONDUIT 19 LIGHTING OUTLET 11 1100 4.78 15A CIRCUIT BREAKER 2 - 2.00 MM2 TW WIRE 13 MM ELECTRIC CONDUIT LIGHTING OUTLET 8 800 3.48 15A CIRCUIT BREAKER 2 - 2.00 MM2 TW WIRE 13 MM ELECTRIC CONDUIT 21 LIGHTING OUTLET 11 1100 4.78 15A CIRCUIT BREAKER 2 - 2.00 MM2 TW WIRE 13 MM ELECTRIC CONDUIT SPARE - - - - - 21 15AT SPARE 21 15AT 3 HP MOTOR 1 2238 9.73 70A CIRCUIT BREAKER 2 - 8.00 MM2 TW WIRE 3. WIRING METHOD SHALL BE AS FOLLOWS: A. FEEDERS AND RISERS - INTERMEDIATE METALLIC CONDUIT B. LIGHTING, POWER RECEPTACLE - POLYVINYL CHLORIDE CONDUIT ELECTRIC CONDUIT - 30 MM 2. THE ELECTRICAL SERVICE POWER IS SINGLE PHASE, 2 - WIRE, 220 V AC, 60 HZ. ELECTRIC CONDUIT 11 20 15AT 12 COOKING UNIT 18 30AT 70AT LIGHTING OUTLET 16 13 70AT 13 14 11 1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE ( PEC ). THE RULES AND REGULATION OF THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION OF A DUTY REGISTERED ELECTRICAL ENGINEER. ELECTRIC CONDUIT 4. ALL WIRES SHOULD BE COPPER AND THERMOPLASTIC INSULATED TYPE " TW " UNLESS OTHERWISE INDICATED ON THE PLAN THE MINIMUM SIZE OF THE WIRE FOR LIGHTING CIRCUIT HOMERUN SHALL BE 2.0 sq. mm AND FOR POWER CIRCUIT HOMERUN SHALL BE 3.5 sq. mm INSULATED FOR 600 VOLTS. SMALLEST RACEWAYS SHALL BE 13 mm DIAMETER TRADE/NOMINAL SIZE. 5. ALL MATERIALS TO BE USED BE BRAND NEW AND APPROVED TYPE FOR PARTICULAR LOCATION AND PURPOSE OF USAGE. - SPARE 22 30 MM ELECTRIC CONDUIT 6. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT. 7. MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS: DRAFTED AND CADD BY: PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROPOSED CONSTRUCTION OF ANGELIE M. MOROSCALLO BSEE-V MARK ANTHONY B. ENOY BSEE-V TWO-STOREY TWO-DOOR APARTMENT BUILDING ENGR. URSINO P. TABILIRAN ELECTRICAL LAYOUT

×