Features
–– Screwless terminal on the load side allows easy, fast and
save wiring
–– Cables can be connected and removed without any tools
–– 2 cables up to 4 mm² are directly pluggable
–– Rigid cables and flexible cables with or without end sleeves can be
connected
–– Best visibility conditions for the wiring due to the
arrangement of the terminal openings
–– Comfortable and exact voltage measurement on the load
side due to the easily accessible measurement point
–– Improved terminal on the supply side for cables up to
35 mm²
–– Approved according to IEC/EN 60898-1 for global use
–– Fully compatible with all System pro M compact®
devices
and accessories
The miniature circuit breaker S 200 S
extends the established ABB
System pro M compact®
product range.
Thanks to the tool-free screwless
terminal technology the S 200 S can be
wired far more quickly and easily than
standard screw-type circuit breakers.
All kinds of cables can be connected.
Rigid cables and flexible cables with
end sleeves can be plugged in the
screwless terminal directly. The easy-
to-use, smooth-running terminal lever
only needs to be pushed to connect
flexible cables without end sleeves or to
disconnect the wiring.
System pro M compact®
Miniature circuit breaker S 200 S
Data sheet
2CDC021001S0010
2CDC021002S0010
2 - 2CDC002137D0201
Miniature circuit breaker S 200 S
Technical data
General data
Standards IEC/EN 60898-1
Number of poles 1P, 3P
Tripping characteristics B, C
Rated current In
6 ... 20 A
Rated frequency f 50/60 Hz
Data acc. to IEC/EN 60898-1
Rated operational voltage Ue
1P: 230 V AC; 3P: 400 V AC
Power frequency recovery voltage (Umax
) 1P: 253 V AC; 3P: 440 V AC
Minimum operational voltage 12 V AC
Rated insulation voltage Ui
Phase to ground 250 V AC
Phase to phase 440 V AC
Rated short-circuit capacity Icn
6 kA
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Rated impulse withstand voltage Uimp
(1.2/50 µs) 4 kV (6.2 kV @ sea level; 5.0 kV @ 2,000 m)
Dielectric test voltage 50/60 Hz, 1 min.: 2 kV
Reference temperature for tripping characteristics 30 °C
Electrical endurance 20,000 operations
Mechanical data
Housing material Insulation group II, RAL 7035
Toggle Insulation group II, black, sealable
Contact position indication Marking on toggle (I ON / 0 OFF)
Degree of protection IP20, IP40 in enclosure with cover
Mechanical endurance 20,000 operations
Resistance to shock acc. to IEC/EN 60068-2-27 25g, 2 shocks, 13 ms
Resistance to vibrations acc. to IEC/EN 60068-2-6 5g, 20 cycles at 5...150...5 Hz with load 0.8 In
Environmental conditions acc. to IEC/EN 60068-2-30 28 cycles with 55 °C / 90-96% and 25 °C / 95-100%
Ambient air temperature Operation -25 … +55 °C
Storage -40 ... +70 °C
Installation
Terminal Line-side Failsafe bi-directional cylinder-lift terminal
Load-side Screwless terminal (2 openings for one cable each)
Cross-section of conductors Line-side 35 mm²
Load-side 1 ... 4 mm² (rigid or flexible wires without end sleeves)
1 … 2.5 mm² (flexible wires with end sleeves)
Cross-section of busbars Line-side 10 mm²
Load-side –
Tightening torques 2.8 Nm
Recommended screw driver Pozidrive 2
Mounting on DIN rail On DIN rail 35 mm acc. to EN 60715 by fast clip
Mounting position Any
Supply Bottom
Dimensions and weight
Mounting dimensions acc. DIN 43880 Mounting dimension 1
Pole dimensions (H x D x W) 89.0 x 69.0 x 17.5 mm
Pole weight 0.100 kg
Combination with auxiliary elements
Auxiliary contact, signal contact, shunt trip, undervoltage release Yes
2CDC002137D0201 - 3
Miniature circuit breaker S 200 S
Tripping characteristics, internal resistance and power loss
Tripping characteristics
B characteristic C characteristic
2CDC022026F0210
2CDC022001F0210
Tripping characteristics acc. to IEC/EN 60898-1
Tripping
characteristic
Rated current Thermal release 1)
Electromagnetic release 2)
Currents Tripping time Range of instantaneous tripping Tripping time
conventional
non-tripping
current
I1
conventional
tripping current
I2
B 6 to 20 A 1.13 · In
1.45 · In
> 1 h
< 1 h
3 · In
  5 · In
0.1 … 45 s
< 0.1 s
C 6 to 20 A 1.13 · In
1.45 · In
> 1 h
< 1 h
5 · In
10 · In
0.1 … 15 s
< 0.1 s
1)
The thermal releases are calibrated to a nominal reference ambient temperature; for B and C the reference value is 30 °C.
In the case of higher ambient temperatures, the current values fall by approx. 6 % for each 10 K temperature rise.
2)
The indicated tripping values of electromagnetic tripping devices apply to a frequency of 50/60 Hz.
The thermal release operates independent of frequency.
Internal resistance and power loss
Tripping characteristic Rated current In
Internal resistance per pole 1)
Power loss per pole 1)
A mΩ W
B, C  6 52.1 2.16
C  8 22.9 1.65
B, C 10 19.0 2.20
B, C 13 13.7 2.62
B, C 16  9.1 3.28
B, C 20  6.2 3.14
1)
Internal resistances and power loss are subject to application-specific and environment-specific conditions and are therefore to be considered as typical values.
4 - 2CDC002137D0201
Miniature circuit breaker S 200 S
Derating
For installations of miniature circuit breakers at other temperatures than the reference value and installations of several
miniature circuit breakers directly side by side, derating factors have to be considered.
Deviating ambient temperature
The rated value of the current of a miniature circuit breaker with B and C characteristic refers to a reference ambient
temperature of 30 °C.
The following table contains the derating of the load capability at ambient temperatures from –40 to 70 °C for the
characteristics B and C.
Rated current In
A
Maximum operating current at ambient temperature T
A
–40 °C –30 °C –20 °C –10 °C 0 °C 10 °C 20 °C 30 °C 40 °C 50 °C 60 °C 70 °C
 6.0  8.0  7.7  7.5  7.2  6.9  6.6  6.3  6.0  5.7  5.3  4.9  4.5
 8.0 10.7 10.3 10.0  9.6  9.2  8.8  8.4  8.0  7.5  7.1  6.5  6.0
10.0 13.3 12.9 12.5 12.0 11.5 11.1 10.5 10.0  9.4  8.8  8.2  7.5
13.0 17.3 16.8 16.2 15.6 15.0 14.4 13.7 13.0 12.3 11.5 10.6  9.7
16.0 21.3 20.7 20.0 19.2 18.5 17.7 16.9 16.0 15.1 14.1 13.1 11.9
20.0 26.7 25.8 24.9 24.0 23.1 22.1 21.1 20.0 18.9 17.6 16.3 14.9
Influence of adjacent devices
If several miniature circuit breakers are installed directly side by side with high load on all poles, a correction factor has to be
applied to the rated current (see table). If distance pieces are used, the factor is not to be considered.
No. of adjacent devices Factor F
1 1
2, 3 0.9
4, 5 0.8
≥ 6 0.75
Example
S201S-C16 at T = 40 °C
Type of use Values to use Calculation Result
Load at ambient temperature In
(40 °C) In
= 15.1 A
Load at ambient temperature with 8 adj. devices In
(40 °C), Factor F 15.1 A x 0.75 In
= 11.33 A
2CDC002137D0201 - 5
Miniature circuit breaker S 200 S
Accessories, dimensional drawing and approvals
Accessory overview
2CDC022032F0211
H	 Auxiliary contact (changeover contact)
S/H	 Signal/auxiliary contact
S/H (H)	 Signal/auxiliary contact used as
auxiliary contact
ST	 Shunt trip
UR	 Undervoltage release
OR	 Overvoltage release
MOD-S(*)
	 Motor operating device
H-L	 Auxiliary contact to be mounted on
the left
H-R	 Auxiliary contact to be mounted on
the right (2 contacts)
H-BF	 Auxiliary contact, bottom fitting
(1 per pole)
BP	 Mechanical tripping device
NT	 Neutral disconnector
(*)
In case of using S 200 S coupled with DDA 200,
MOD-S doesn’t operate in case of earth-leakage fault.
Dimensional drawing
2CDC022222F0009
Approvals
J VDE Germany
IMQ Italy
KEMA Netherlands
LCIE France
ÖVE Austria
SEV Switzerland
6 - 2CDC002137D0201
Miniature circuit breaker S 200 S
Instructions for use
Connection and disconnection of different types of cables on the load side
Type of cables and cross sections
2CDC022027F0211
Connection of cables
2CDC022028F0211
–– Connection of one cable per opening
–– Rigid and flexible cables with end sleeves may be directly connected.
–– If flexible cables without end sleeves are to be connected, the terminal must be opened. Splicing of the wires must be
avoided.
–– The cable must be inserted into the terminal either as far as possible or in such a way that a sufficient connection is obvious.
–– The tightness of the connection must be checked.
Disconnection of cables
2CDC022029F0211
–– The cables may only be removed after operating the terminal’s opening mechanism.
–– If one cable is removed, the correct position of the remaining cable must be checked.
Processing instructions
The screwless terminal at the load side of the S 200 S is designed so that copper cables basically may be connected without
further preparation. If end sleeves are used as splicing protection for flexible cables, the compression of the end sleeves
must comply with the pull-out forces in accordance with standard IEC/EN 60898-1 table J.3.	
Recommended tools for flexible cables with end sleeves
Crimp tool with trapezoid compression profile
Wire stripping length / size of end sleeves for all cables
Wire stripping length and end sleeve length 12 (+2) mm
Distribution boards with metal cover
The distance from a metallic cover to the “shoulder” of the miniature circuit breaker must be at least 6 mm on the load side
due to the arrangement of the easily accessible measurement point.
2CDC002137D0201 - 7
Miniature circuit breaker S 200 S
Order data
2CDC021001S0010
S201S
2CDC021002S0010
S203S
Tripping
characteristic
Number of
poles
Rated
current In
Type Order code Packing
unit
Weight
per PCE
A PCE kg
B 1 6 S201S-B6 2CDS251002R0065 10 0.100
10 S201S-B10 2CDS251002R0105 10 0.100
13 S201S-B13 2CDS251002R0135 10 0.100
16 S201S-B16 2CDS251002R0165 10 0.100
20 S201S-B20 2CDS251002R0205 10 0.100
3 6 S203S-B6 2CDS253002R0065 1 0.300
10 S203S-B10 2CDS253002R0105 1 0.300
13 S203S-B13 2CDS253002R0135 1 0.300
16 S203S-B16 2CDS253002R0165 1 0.300
20 S203S-B20 2CDS253002R0205 1 0.300
C 1 6 S201S-C6 2CDS251002R0064 10 0.100
8 S201S-C8 2CDS251002R0084 10 0.100
10 S201S-C10 2CDS251002R0104 10 0.100
13 S201S-C13 2CDS251002R0134 10 0.100
16 S201S-C16 2CDS251002R0164 10 0.100
20 S201S-C20 2CDS251002R0204 10 0.100
3 6 S203S-C6 2CDS253002R0064 1 0.300
8 S203S-C8 2CDS253002R0084 1 0.300
10 S203S-C10 2CDS253002R0104 1 0.300
13 S203S-C13 2CDS253002R0134 1 0.300
16 S203S-C16 2CDS253002R0164 1 0.300
20 S203S-C20 2CDS253002R0204 1 0.300
ABB STOTZ-KONTAKT GmbH
Eppelheimer Straße 82
69123 Heidelberg, Germany
Phone: +49 (0) 6221 7 01-0
Fax: +49 (0) 6221 7 01-13 25
E-Mail: info.desto@de.abb.com
You can find the address of your
local sales organization on the
ABB home page
http://www.abb.com/contacts
-> Low Voltage Products and Systems
Contact us
Note:
We reserve the right to make technical changes
or modify the contents of this document without
prior notice. With regard to purchase orders, the
agreed particulars shall prevail. ABB AG does
not accept any responsibility whatsoever for
potential errors or possible lack of information in
this document.
We reserve all rights in this document and in
the subject matter and illustrations contained
therein. Any reproduction, disclosure to third
parties or utilization of its contents – in whole
or in parts – is forbidden without prior written
consent of ABB AG.
Copyright© 2011 ABB
All rights reserved
Ordernumber2CDC002137D0201printedinGermany(07/11-5-ZVD)

More Related Content

What's hot

Fluke Digital Multimeter Selection Guide
Fluke Digital Multimeter Selection GuideFluke Digital Multimeter Selection Guide
Fluke Digital Multimeter Selection GuideCoasttoCoastCape
 
Catalog MCCB LS metasol tổng hợp - beeteco.com
Catalog MCCB LS metasol tổng hợp - beeteco.comCatalog MCCB LS metasol tổng hợp - beeteco.com
Catalog MCCB LS metasol tổng hợp - beeteco.comBeeteco
 
6ES7331-7KF02-0AB0 manual
6ES7331-7KF02-0AB0 manual6ES7331-7KF02-0AB0 manual
6ES7331-7KF02-0AB0 manualsteven qi
 
Cataloge schneider contactor ct-dienhathe.vn
Cataloge schneider contactor ct-dienhathe.vnCataloge schneider contactor ct-dienhathe.vn
Cataloge schneider contactor ct-dienhathe.vnDien Ha The
 
Delta drp024 power_supply_catalog
Delta drp024 power_supply_catalogDelta drp024 power_supply_catalog
Delta drp024 power_supply_catalogElectromate
 
Low voltage circuit breakers & contactors general leaflet ls
Low voltage circuit breakers & contactors general leaflet   lsLow voltage circuit breakers & contactors general leaflet   ls
Low voltage circuit breakers & contactors general leaflet lsmaianhbao_6519
 
ABB Contactors - 4 Pole Contactors ABB AF09 AF09Z (AC DC) Contactors
ABB Contactors - 4 Pole Contactors ABB AF09 AF09Z  (AC DC) ContactorsABB Contactors - 4 Pole Contactors ABB AF09 AF09Z  (AC DC) Contactors
ABB Contactors - 4 Pole Contactors ABB AF09 AF09Z (AC DC) ContactorsThorne & Derrick International
 
LS Circuit Breaker Catalogue
LS Circuit Breaker CatalogueLS Circuit Breaker Catalogue
LS Circuit Breaker Cataloguehairxoawn
 
6ES7322-1BL00-0AA0
6ES7322-1BL00-0AA06ES7322-1BL00-0AA0
6ES7322-1BL00-0AA0steven qi
 
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensor
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensorOrbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensor
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensorENVIMART
 
Aml catalogue 13
Aml catalogue 13Aml catalogue 13
Aml catalogue 13slideroma
 
Contactor thermal relay catalogue
Contactor thermal relay catalogueContactor thermal relay catalogue
Contactor thermal relay catalogueJohnson lim
 
Rsf electronik msr20_msr4_catalog
Rsf electronik msr20_msr4_catalogRsf electronik msr20_msr4_catalog
Rsf electronik msr20_msr4_catalogElectromate
 
Catalog CB tép MCB 2P 3P 4P BKN BKH LS
Catalog CB tép MCB 2P 3P 4P BKN BKH LSCatalog CB tép MCB 2P 3P 4P BKN BKH LS
Catalog CB tép MCB 2P 3P 4P BKN BKH LSBeeteco
 
LS Wiring Device Catalog
LS Wiring Device CatalogLS Wiring Device Catalog
LS Wiring Device Cataloghairxoawn
 

What's hot (17)

Fluke Digital Multimeter Selection Guide
Fluke Digital Multimeter Selection GuideFluke Digital Multimeter Selection Guide
Fluke Digital Multimeter Selection Guide
 
Pressure sensor module ms5535-30 c
Pressure sensor module   ms5535-30 cPressure sensor module   ms5535-30 c
Pressure sensor module ms5535-30 c
 
Catalog MCCB LS metasol tổng hợp - beeteco.com
Catalog MCCB LS metasol tổng hợp - beeteco.comCatalog MCCB LS metasol tổng hợp - beeteco.com
Catalog MCCB LS metasol tổng hợp - beeteco.com
 
6ES7331-7KF02-0AB0 manual
6ES7331-7KF02-0AB0 manual6ES7331-7KF02-0AB0 manual
6ES7331-7KF02-0AB0 manual
 
Cataloge schneider contactor ct-dienhathe.vn
Cataloge schneider contactor ct-dienhathe.vnCataloge schneider contactor ct-dienhathe.vn
Cataloge schneider contactor ct-dienhathe.vn
 
Delta drp024 power_supply_catalog
Delta drp024 power_supply_catalogDelta drp024 power_supply_catalog
Delta drp024 power_supply_catalog
 
Low voltage circuit breakers & contactors general leaflet ls
Low voltage circuit breakers & contactors general leaflet   lsLow voltage circuit breakers & contactors general leaflet   ls
Low voltage circuit breakers & contactors general leaflet ls
 
ABB Contactors - 4 Pole Contactors ABB AF09 AF09Z (AC DC) Contactors
ABB Contactors - 4 Pole Contactors ABB AF09 AF09Z  (AC DC) ContactorsABB Contactors - 4 Pole Contactors ABB AF09 AF09Z  (AC DC) Contactors
ABB Contactors - 4 Pole Contactors ABB AF09 AF09Z (AC DC) Contactors
 
Mv design guide
Mv design guideMv design guide
Mv design guide
 
LS Circuit Breaker Catalogue
LS Circuit Breaker CatalogueLS Circuit Breaker Catalogue
LS Circuit Breaker Catalogue
 
6ES7322-1BL00-0AA0
6ES7322-1BL00-0AA06ES7322-1BL00-0AA0
6ES7322-1BL00-0AA0
 
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensor
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensorOrbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensor
Orbipac cpf81 cpf81 d_cpf82_cpf82d-endress+hauser datasheet-ph sensor
 
Aml catalogue 13
Aml catalogue 13Aml catalogue 13
Aml catalogue 13
 
Contactor thermal relay catalogue
Contactor thermal relay catalogueContactor thermal relay catalogue
Contactor thermal relay catalogue
 
Rsf electronik msr20_msr4_catalog
Rsf electronik msr20_msr4_catalogRsf electronik msr20_msr4_catalog
Rsf electronik msr20_msr4_catalog
 
Catalog CB tép MCB 2P 3P 4P BKN BKH LS
Catalog CB tép MCB 2P 3P 4P BKN BKH LSCatalog CB tép MCB 2P 3P 4P BKN BKH LS
Catalog CB tép MCB 2P 3P 4P BKN BKH LS
 
LS Wiring Device Catalog
LS Wiring Device CatalogLS Wiring Device Catalog
LS Wiring Device Catalog
 

Viewers also liked

Viewers also liked (8)

Gravedad pesas
Gravedad pesasGravedad pesas
Gravedad pesas
 
Tutorial matlab
Tutorial matlabTutorial matlab
Tutorial matlab
 
Tecnical aplicacion1 abb
Tecnical aplicacion1 abbTecnical aplicacion1 abb
Tecnical aplicacion1 abb
 
La fuente magnetica es2
La fuente magnetica es2La fuente magnetica es2
La fuente magnetica es2
 
Tablas+de+estatica
Tablas+de+estaticaTablas+de+estatica
Tablas+de+estatica
 
Manual de uso y manejo de extintores
Manual de uso y manejo de extintoresManual de uso y manejo de extintores
Manual de uso y manejo de extintores
 
Fundamentos de electromagnetismo
Fundamentos de electromagnetismoFundamentos de electromagnetismo
Fundamentos de electromagnetismo
 
Manual+del+carrozado camiones
Manual+del+carrozado camionesManual+del+carrozado camiones
Manual+del+carrozado camiones
 

Similar to Sistem breaker pro abb

K30 Temperature Controller
K30 Temperature ControllerK30 Temperature Controller
K30 Temperature ControllerJoseph
 
K38 Controller
K38 ControllerK38 Controller
K38 ControllerJoseph
 
K49 Controller
K49 ControllerK49 Controller
K49 ControllerJoseph
 
K31 Controller
K31 ControllerK31 Controller
K31 ControllerJoseph
 
Brochure_BMS..08_SG202168BEN_B06-0914
Brochure_BMS..08_SG202168BEN_B06-0914Brochure_BMS..08_SG202168BEN_B06-0914
Brochure_BMS..08_SG202168BEN_B06-0914Patrick Volluz
 
K39 Controller
K39 ControllerK39 Controller
K39 ControllerJoseph
 
K48 Controller
K48 ControllerK48 Controller
K48 ControllerJoseph
 
Gelbyson Christie K Series MagAmp Power Supplies
Gelbyson Christie K Series MagAmp Power SuppliesGelbyson Christie K Series MagAmp Power Supplies
Gelbyson Christie K Series MagAmp Power Suppliesgelbyson
 
K32 Controller
K32 ControllerK32 Controller
K32 ControllerJoseph
 
Cataloge schneider contactor ct
Cataloge schneider contactor ctCataloge schneider contactor ct
Cataloge schneider contactor ctDien Ha The
 
Cataloge schneider contactor ct
Cataloge schneider contactor ctCataloge schneider contactor ct
Cataloge schneider contactor ctDien Ha The
 
Cataloge schneider contactor ct
Cataloge schneider contactor ctCataloge schneider contactor ct
Cataloge schneider contactor ctDien Ha The
 
Cataloge schneider contactor ct
Cataloge schneider contactor ctCataloge schneider contactor ct
Cataloge schneider contactor ctDien Ha The
 
Catalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vnCatalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vnDien Ha The
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccbThuan Kieu
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdpThuan Kieu
 
Catalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vnCatalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vnDien Ha The
 

Similar to Sistem breaker pro abb (20)

K30 Temperature Controller
K30 Temperature ControllerK30 Temperature Controller
K30 Temperature Controller
 
K38 Controller
K38 ControllerK38 Controller
K38 Controller
 
K49 Controller
K49 ControllerK49 Controller
K49 Controller
 
K31 Controller
K31 ControllerK31 Controller
K31 Controller
 
Brochure_BMS..08_SG202168BEN_B06-0914
Brochure_BMS..08_SG202168BEN_B06-0914Brochure_BMS..08_SG202168BEN_B06-0914
Brochure_BMS..08_SG202168BEN_B06-0914
 
K39 Controller
K39 ControllerK39 Controller
K39 Controller
 
K48 Controller
K48 ControllerK48 Controller
K48 Controller
 
Gelbyson Christie K Series MagAmp Power Supplies
Gelbyson Christie K Series MagAmp Power SuppliesGelbyson Christie K Series MagAmp Power Supplies
Gelbyson Christie K Series MagAmp Power Supplies
 
08 - Circuit Protector - Fuji Electric
08 - Circuit Protector - Fuji Electric08 - Circuit Protector - Fuji Electric
08 - Circuit Protector - Fuji Electric
 
K32 Controller
K32 ControllerK32 Controller
K32 Controller
 
Electromagnetic Flow Monitor Magphant
Electromagnetic Flow Monitor MagphantElectromagnetic Flow Monitor Magphant
Electromagnetic Flow Monitor Magphant
 
Cataloge schneider contactor ct
Cataloge schneider contactor ctCataloge schneider contactor ct
Cataloge schneider contactor ct
 
Cataloge schneider contactor ct
Cataloge schneider contactor ctCataloge schneider contactor ct
Cataloge schneider contactor ct
 
Cataloge schneider contactor ct
Cataloge schneider contactor ctCataloge schneider contactor ct
Cataloge schneider contactor ct
 
Cataloge schneider contactor ct
Cataloge schneider contactor ctCataloge schneider contactor ct
Cataloge schneider contactor ct
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
 
Catalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vnCatalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vn
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
 
Catalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vnCatalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vn
 

More from isaac diaz said

More from isaac diaz said (11)

Unidadfenomenos
UnidadfenomenosUnidadfenomenos
Unidadfenomenos
 
Especialista seguridad industrial
Especialista seguridad industrialEspecialista seguridad industrial
Especialista seguridad industrial
 
Capitulo 2 (deformacion)
Capitulo 2 (deformacion)Capitulo 2 (deformacion)
Capitulo 2 (deformacion)
 
Cat. tecnico system pro m compact
Cat. tecnico system pro m compactCat. tecnico system pro m compact
Cat. tecnico system pro m compact
 
Ejercicios centro-de-gravedad
Ejercicios centro-de-gravedadEjercicios centro-de-gravedad
Ejercicios centro-de-gravedad
 
Cálculo tensorial3
Cálculo tensorial3Cálculo tensorial3
Cálculo tensorial3
 
Complejos2
Complejos2Complejos2
Complejos2
 
Energias libres
Energias libresEnergias libres
Energias libres
 
Tubos galvanizados foll colmena
Tubos galvanizados foll colmenaTubos galvanizados foll colmena
Tubos galvanizados foll colmena
 
Elec2 electromagnetismo
Elec2 electromagnetismoElec2 electromagnetismo
Elec2 electromagnetismo
 
Abb minibreakers de riel (din)
Abb minibreakers de riel (din)Abb minibreakers de riel (din)
Abb minibreakers de riel (din)
 

Sistem breaker pro abb

  • 1. Features –– Screwless terminal on the load side allows easy, fast and save wiring –– Cables can be connected and removed without any tools –– 2 cables up to 4 mm² are directly pluggable –– Rigid cables and flexible cables with or without end sleeves can be connected –– Best visibility conditions for the wiring due to the arrangement of the terminal openings –– Comfortable and exact voltage measurement on the load side due to the easily accessible measurement point –– Improved terminal on the supply side for cables up to 35 mm² –– Approved according to IEC/EN 60898-1 for global use –– Fully compatible with all System pro M compact® devices and accessories The miniature circuit breaker S 200 S extends the established ABB System pro M compact® product range. Thanks to the tool-free screwless terminal technology the S 200 S can be wired far more quickly and easily than standard screw-type circuit breakers. All kinds of cables can be connected. Rigid cables and flexible cables with end sleeves can be plugged in the screwless terminal directly. The easy- to-use, smooth-running terminal lever only needs to be pushed to connect flexible cables without end sleeves or to disconnect the wiring. System pro M compact® Miniature circuit breaker S 200 S Data sheet 2CDC021001S0010 2CDC021002S0010
  • 2. 2 - 2CDC002137D0201 Miniature circuit breaker S 200 S Technical data General data Standards IEC/EN 60898-1 Number of poles 1P, 3P Tripping characteristics B, C Rated current In 6 ... 20 A Rated frequency f 50/60 Hz Data acc. to IEC/EN 60898-1 Rated operational voltage Ue 1P: 230 V AC; 3P: 400 V AC Power frequency recovery voltage (Umax ) 1P: 253 V AC; 3P: 440 V AC Minimum operational voltage 12 V AC Rated insulation voltage Ui Phase to ground 250 V AC Phase to phase 440 V AC Rated short-circuit capacity Icn 6 kA Energy limiting class 3 Overvoltage category III Pollution degree 2 Rated impulse withstand voltage Uimp (1.2/50 µs) 4 kV (6.2 kV @ sea level; 5.0 kV @ 2,000 m) Dielectric test voltage 50/60 Hz, 1 min.: 2 kV Reference temperature for tripping characteristics 30 °C Electrical endurance 20,000 operations Mechanical data Housing material Insulation group II, RAL 7035 Toggle Insulation group II, black, sealable Contact position indication Marking on toggle (I ON / 0 OFF) Degree of protection IP20, IP40 in enclosure with cover Mechanical endurance 20,000 operations Resistance to shock acc. to IEC/EN 60068-2-27 25g, 2 shocks, 13 ms Resistance to vibrations acc. to IEC/EN 60068-2-6 5g, 20 cycles at 5...150...5 Hz with load 0.8 In Environmental conditions acc. to IEC/EN 60068-2-30 28 cycles with 55 °C / 90-96% and 25 °C / 95-100% Ambient air temperature Operation -25 … +55 °C Storage -40 ... +70 °C Installation Terminal Line-side Failsafe bi-directional cylinder-lift terminal Load-side Screwless terminal (2 openings for one cable each) Cross-section of conductors Line-side 35 mm² Load-side 1 ... 4 mm² (rigid or flexible wires without end sleeves) 1 … 2.5 mm² (flexible wires with end sleeves) Cross-section of busbars Line-side 10 mm² Load-side – Tightening torques 2.8 Nm Recommended screw driver Pozidrive 2 Mounting on DIN rail On DIN rail 35 mm acc. to EN 60715 by fast clip Mounting position Any Supply Bottom Dimensions and weight Mounting dimensions acc. DIN 43880 Mounting dimension 1 Pole dimensions (H x D x W) 89.0 x 69.0 x 17.5 mm Pole weight 0.100 kg Combination with auxiliary elements Auxiliary contact, signal contact, shunt trip, undervoltage release Yes
  • 3. 2CDC002137D0201 - 3 Miniature circuit breaker S 200 S Tripping characteristics, internal resistance and power loss Tripping characteristics B characteristic C characteristic 2CDC022026F0210 2CDC022001F0210 Tripping characteristics acc. to IEC/EN 60898-1 Tripping characteristic Rated current Thermal release 1) Electromagnetic release 2) Currents Tripping time Range of instantaneous tripping Tripping time conventional non-tripping current I1 conventional tripping current I2 B 6 to 20 A 1.13 · In 1.45 · In > 1 h < 1 h 3 · In   5 · In 0.1 … 45 s < 0.1 s C 6 to 20 A 1.13 · In 1.45 · In > 1 h < 1 h 5 · In 10 · In 0.1 … 15 s < 0.1 s 1) The thermal releases are calibrated to a nominal reference ambient temperature; for B and C the reference value is 30 °C. In the case of higher ambient temperatures, the current values fall by approx. 6 % for each 10 K temperature rise. 2) The indicated tripping values of electromagnetic tripping devices apply to a frequency of 50/60 Hz. The thermal release operates independent of frequency. Internal resistance and power loss Tripping characteristic Rated current In Internal resistance per pole 1) Power loss per pole 1) A mΩ W B, C  6 52.1 2.16 C  8 22.9 1.65 B, C 10 19.0 2.20 B, C 13 13.7 2.62 B, C 16  9.1 3.28 B, C 20  6.2 3.14 1) Internal resistances and power loss are subject to application-specific and environment-specific conditions and are therefore to be considered as typical values.
  • 4. 4 - 2CDC002137D0201 Miniature circuit breaker S 200 S Derating For installations of miniature circuit breakers at other temperatures than the reference value and installations of several miniature circuit breakers directly side by side, derating factors have to be considered. Deviating ambient temperature The rated value of the current of a miniature circuit breaker with B and C characteristic refers to a reference ambient temperature of 30 °C. The following table contains the derating of the load capability at ambient temperatures from –40 to 70 °C for the characteristics B and C. Rated current In A Maximum operating current at ambient temperature T A –40 °C –30 °C –20 °C –10 °C 0 °C 10 °C 20 °C 30 °C 40 °C 50 °C 60 °C 70 °C  6.0  8.0  7.7  7.5  7.2  6.9  6.6  6.3  6.0  5.7  5.3  4.9  4.5  8.0 10.7 10.3 10.0  9.6  9.2  8.8  8.4  8.0  7.5  7.1  6.5  6.0 10.0 13.3 12.9 12.5 12.0 11.5 11.1 10.5 10.0  9.4  8.8  8.2  7.5 13.0 17.3 16.8 16.2 15.6 15.0 14.4 13.7 13.0 12.3 11.5 10.6  9.7 16.0 21.3 20.7 20.0 19.2 18.5 17.7 16.9 16.0 15.1 14.1 13.1 11.9 20.0 26.7 25.8 24.9 24.0 23.1 22.1 21.1 20.0 18.9 17.6 16.3 14.9 Influence of adjacent devices If several miniature circuit breakers are installed directly side by side with high load on all poles, a correction factor has to be applied to the rated current (see table). If distance pieces are used, the factor is not to be considered. No. of adjacent devices Factor F 1 1 2, 3 0.9 4, 5 0.8 ≥ 6 0.75 Example S201S-C16 at T = 40 °C Type of use Values to use Calculation Result Load at ambient temperature In (40 °C) In = 15.1 A Load at ambient temperature with 8 adj. devices In (40 °C), Factor F 15.1 A x 0.75 In = 11.33 A
  • 5. 2CDC002137D0201 - 5 Miniature circuit breaker S 200 S Accessories, dimensional drawing and approvals Accessory overview 2CDC022032F0211 H Auxiliary contact (changeover contact) S/H Signal/auxiliary contact S/H (H) Signal/auxiliary contact used as auxiliary contact ST Shunt trip UR Undervoltage release OR Overvoltage release MOD-S(*) Motor operating device H-L Auxiliary contact to be mounted on the left H-R Auxiliary contact to be mounted on the right (2 contacts) H-BF Auxiliary contact, bottom fitting (1 per pole) BP Mechanical tripping device NT Neutral disconnector (*) In case of using S 200 S coupled with DDA 200, MOD-S doesn’t operate in case of earth-leakage fault. Dimensional drawing 2CDC022222F0009 Approvals J VDE Germany IMQ Italy KEMA Netherlands LCIE France ÖVE Austria SEV Switzerland
  • 6. 6 - 2CDC002137D0201 Miniature circuit breaker S 200 S Instructions for use Connection and disconnection of different types of cables on the load side Type of cables and cross sections 2CDC022027F0211 Connection of cables 2CDC022028F0211 –– Connection of one cable per opening –– Rigid and flexible cables with end sleeves may be directly connected. –– If flexible cables without end sleeves are to be connected, the terminal must be opened. Splicing of the wires must be avoided. –– The cable must be inserted into the terminal either as far as possible or in such a way that a sufficient connection is obvious. –– The tightness of the connection must be checked. Disconnection of cables 2CDC022029F0211 –– The cables may only be removed after operating the terminal’s opening mechanism. –– If one cable is removed, the correct position of the remaining cable must be checked. Processing instructions The screwless terminal at the load side of the S 200 S is designed so that copper cables basically may be connected without further preparation. If end sleeves are used as splicing protection for flexible cables, the compression of the end sleeves must comply with the pull-out forces in accordance with standard IEC/EN 60898-1 table J.3. Recommended tools for flexible cables with end sleeves Crimp tool with trapezoid compression profile Wire stripping length / size of end sleeves for all cables Wire stripping length and end sleeve length 12 (+2) mm Distribution boards with metal cover The distance from a metallic cover to the “shoulder” of the miniature circuit breaker must be at least 6 mm on the load side due to the arrangement of the easily accessible measurement point.
  • 7. 2CDC002137D0201 - 7 Miniature circuit breaker S 200 S Order data 2CDC021001S0010 S201S 2CDC021002S0010 S203S Tripping characteristic Number of poles Rated current In Type Order code Packing unit Weight per PCE A PCE kg B 1 6 S201S-B6 2CDS251002R0065 10 0.100 10 S201S-B10 2CDS251002R0105 10 0.100 13 S201S-B13 2CDS251002R0135 10 0.100 16 S201S-B16 2CDS251002R0165 10 0.100 20 S201S-B20 2CDS251002R0205 10 0.100 3 6 S203S-B6 2CDS253002R0065 1 0.300 10 S203S-B10 2CDS253002R0105 1 0.300 13 S203S-B13 2CDS253002R0135 1 0.300 16 S203S-B16 2CDS253002R0165 1 0.300 20 S203S-B20 2CDS253002R0205 1 0.300 C 1 6 S201S-C6 2CDS251002R0064 10 0.100 8 S201S-C8 2CDS251002R0084 10 0.100 10 S201S-C10 2CDS251002R0104 10 0.100 13 S201S-C13 2CDS251002R0134 10 0.100 16 S201S-C16 2CDS251002R0164 10 0.100 20 S201S-C20 2CDS251002R0204 10 0.100 3 6 S203S-C6 2CDS253002R0064 1 0.300 8 S203S-C8 2CDS253002R0084 1 0.300 10 S203S-C10 2CDS253002R0104 1 0.300 13 S203S-C13 2CDS253002R0134 1 0.300 16 S203S-C16 2CDS253002R0164 1 0.300 20 S203S-C20 2CDS253002R0204 1 0.300
  • 8. ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-Mail: info.desto@de.abb.com You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Contact us Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copyright© 2011 ABB All rights reserved Ordernumber2CDC002137D0201printedinGermany(07/11-5-ZVD)