SlideShare a Scribd company logo
1 of 28
Download to read offline
© 2013 ANSYS, Inc. May 21, 2013 1 Release 14.5
Lecture 3:
Static Magnetic Solvers
ANSYS Maxwell V16
Training Manual
© 2013 ANSYS, Inc. May 21, 2013 2 Release 14.5
A. Magnetostatic Solver
a. Selecting the Magnetostatic Solver
b. Material Definition
c. Boundary Conditions
d. Excitations
e. Parameters
f. Analysis Setup
g. Solution Process
B. Eddy Current Solver
a. Selecting the Eddy Current Solver
b. Material Definition
c. Boundary Conditions
d. Excitations
e. Parameters
f. Analysis Setup
g. Solution Process
Content
© 2013 ANSYS, Inc. May 21, 2013 3 Release 14.5
A. Magnetostatic Solver
Magnetostatic Solver
– In the Magnetostatic Solver, a static magnetic field is solved resulting from a DC
current flowing through a coil or due to a permanent magnet
– The Electric field inside the current carrying coil is completely decoupled from
magnetic field
– Losses are only due to Ohmic losses in current carrying conductors
– The Magnetostatic solver utilizes an automatic adaptive mesh refinement
technique to achieve an accurate and efficient mesh required to meet defined
accuracy level (energy error).
Magnetostatic Equations
– Following two Maxwell’s equations are solved with Magnetostatic solver
pr MHMH(μB
B
JH



000 )
0







 )),((1),(
0
yxAyxJ z
r
z

Maxwell 3D
Maxwell 2D
© 2013 ANSYS, Inc. May 21, 2013 4 Release 14.5
a. Selecting the Magnetostatic Problem
Selecting the Magnetostatic Solver
– By default, any newly created design will be set as a Magnetostatic problem
– Specify the Magnetostatic Solver by selecting the menu item Maxwell 2D/3D 
Solution Type
– In Solution type window, select Magnetic> Magnetostatic and press OK
Maxwell 3D Maxwell 2D
© 2013 ANSYS, Inc. May 21, 2013 5 Release 14.5
b. Material Definition
Magnetostatic Material Properties
– In a Magnetostatic simulation, the following parameters may be defined for a
material (by clicking on the pull-down menu under Type and Value)
Magnetic Coercivity:
• Used to define permanent magnetization of magnetic
materials.
• Requires magnitude and direction specification.
• Direction specified is with respect to Orientation CS
of bodies to which material is assigned
Composition:
• Can be Solid or Lamination
• Setting Composition to Lamination creates an
anisotropic magnetization effect.
Relative Permeability:
• Permeability (µ) is defined as µ0*µr
• Relative permeability(µr) along with the Magnetic Coercivity determine the magnetic
properties of the material.
• Relative permeability can be Simple(linear µr) or Nonlinear(BH Curve) or/and anisotropic
Bulk Conductivity:
• Used to determine the current distribution in current carrying conductors
• Does not have any impact on magnetic part of analysis
• Can be Simple or Anisotropic
© 2013 ANSYS, Inc. May 21, 2013 6 Release 14.5
c. Boundary Conditions
Assigning Boundary Conditions in 3D
– Boundary conditions define behavior of the magnetic field at the interfaces or
the edges of the problem region
– A boundary can be assigned to a face from menu item Maxwell 3D 
Boundaries  Assign and select the required boundary assignment
Boundary Types(3D)
NaturalNeumann
Default (No Boundary Assigned):
When no boundary is specified for a surface, following two treatments are assigned based on the
surface position
• Natural: for the boundaries on the interface between objects. H Field is continuous across
the boundary.
• Neumann: For exterior boundaries of solution domain. H Field is tangential to the
boundary and flux cannot cross it.
H Vectors
© 2013 ANSYS, Inc. May 21, 2013 7 Release 14.5
…Boundary Conditions
Boundary Types (3D)
Tangential H-Field:
• Useful to assign external field.
• Tangential H field is applied using U and V
components
• Can be applied to external boundaries of the
domain
Insulating:
• Same as Neumann, except that current cannot cross the boundary.
• Can be used to insulate two conductors which are in contact with each other
J Vectors without insulating
boundary between plates
J Vectors with insulating boundary
defined between plates
Zero Tangential H-Field:
• Useful to assign external field.
• H field is normal to assigned surface
• Can be applied to external boundaries of the
domain
H Vectors on Zero
Tangential H field
boundary
H Vectors on
Tangential H field
boundary
© 2013 ANSYS, Inc. May 21, 2013 8 Release 14.5
…Boundary Conditions
Boundary Types (2D)
Note: In 2D, no default boundary is assigned to the boundaries of the simulation
region. Users have to specify the behavior of simulation boundaries by assigning
either Balloon or vector potential boundary.
Vector Potential:
• Sets the specified value of magnetic vector potential on the boundary.
• Used to model Magnetically isolated structures.
Balloon:
• Models the region outside drawing space as being infinitely large.
• Magnetic flux lines are neither tangential nor normal to the boundary
Flux lines with zero vector potential on outer boundary
Flux lines with Balloon on outer boundary
© 2013 ANSYS, Inc. May 21, 2013 9 Release 14.5
…Boundary Conditions
Boundary Types (2D & 3D):
Symmetry Boundary:
• Enable users to model only part of a structure, which reduces the size or complexity of design,
thereby shortening the solution time.
• Applied to external boundaries of domain.
Symmetry Odd: Same as default
Boundary (Flux Tangential)
Symmetry Even: Same as Zero Tangential
H-Field boundary (Flux Normal)
1/8th Model
Master/Slave :
• Enable users to model only one period of a periodic structure, which reduces the design size
• This boundary condition matches the magnetic field at the slave boundary to the field at the
master boundary based on U and V vectors defined.
Master = Slave Master = -Slave
1/4th Model
© 2013 ANSYS, Inc. May 21, 2013 10 Release 14.5
d. Excitations
Assigning Excitations
– Excitations can be assigned from the menu item Maxwell 2D/3D  Excitations 
Assign
Excitation (2D & 3D)
Current :
• Defines total current in Amp-turns through the conductor
• Can be assigned to the conductor faces that lie on boundary of
simulation domain or sheets that lie completely inside the conductor
• Conductor can be defined as Solid or Stranded
Incorrect Excitation definitions Correctly defined Excitations
Current Density:
• Used to define a known current density throughout an object.
• In 3D, this definition should be accompanied with Current Density
Terminal definition
• Current Density defined using X,Y and Z components of selected CS
© 2013 ANSYS, Inc. May 21, 2013 11 Release 14.5
…Excitations
Excitation (3D)
Voltage :
• Used in conjunction with material conductivity
to define current through a solid conductor
• Can only be assigned to faces or sheets that lie
on the boundary of simulation domain
Voltage Drop:
• Similar to the voltage definition
• Can only be assigned to sheets which lie
completely inside the conduction path
Current Density Terminal:
• Required to be defined if Current Density is defined
• Can be assigned to any 2D sheet which lies
completely inside the conductor or Conductor faces
that lie on the boundary of simulation domain
© 2013 ANSYS, Inc. May 21, 2013 12 Release 14.5
e. Parameters
Parameters
– Three calculation parameters can be assigned for magnetostatic solver which
are computed using magnetic field solution
– A parameter can be added by selecting the required object and selecting menu
item Maxwell 3D/2D  Parameters  Assign
Force:
• Calculates force acting on assigned object
• Force can be Virtual or Lorentz
• Lorentz can not be used for magnetic material
Torque:
• Calculates torque on assigned object
• Torque can be Virtual or Lorentz
Matrix:
• Calculates Inductance, resistance matrix
• Calculated matrix can be postprocessed
based on defined groups
© 2013 ANSYS, Inc. May 21, 2013 13 Release 14.5
f. Analysis Setup
Solution Setup
– The solution setup defines the parameters used for solving the simulation
– A Solution Setup can be added from the menu item Maxwell 3D/2D  Analysis
Setup  Add Solution Setup
General Tab
• Name: sets the Name of the setup. Users can have multiple setups
in the same design by repeating the procedure
• Maximum Number of Passes: Defines a limit to the number of
adaptively refined passes that the solver performs
• Percent Error: Error goal for both Error Energy and Delta Energy.
• Solve Fields Only: Ignores any defined parameters if checked.
• Solve Matrix: Provides the options of calculating the matrix after
the last solved pass or only if the solution converges.
Convergence Tab
• Refinement Per Pass: Defines the number of tetrahedral elements
added during mesh refinement as a percentage of the previous pass
• Minimum Number of Passes: Defines the minimum number of
adaptive passes before the solution stops - if there is a conflict, this
value is over-ridden by Maximum Number of Passes
• Minimum Converged Passes: Defines the minimum number of
converged adaptive passed before solution is stopped
© 2013 ANSYS, Inc. May 21, 2013 14 Release 14.5
…Analysis Setup
Solution Setup
Expression Cache Tab:
• Enables users to define Output calculations at each adaptive
pass or set an additional convergence criteria based on added
parameters.
• Solution Setup should be completely defined first to enable
adding Expression Cache variables
• Clicking on Add button enables users to define Output
quantities which can be any defined parameters or derived
quantities from Field Calculator
• Selecting the tab under Convergence will enable users to add
the selected quantity as a convergence criteria
• Users can define the permissible change in output
quantity in percentile or absolute value
• Output quantity will be evaluated at each Adaptive pass.
• If the change in defined output is less than specified
value, the solution is considered to be converged
provided that energy is already converged.
© 2013 ANSYS, Inc. May 21, 2013 15 Release 14.5
…Analysis Setup
Solution Setup
Solver Tab
• Nonlinear Residual: Defines how precisely the nonlinear
solution must define the B-H nonlinear operating points
• Enable Iterative Solver: Enables ICCG solvers (Direct is the
default).
• Permeability Option: Allows nonlinear B-H operating points
either to be calculated by the solver from Nonlinear B-H curve
or to use frozen permeabilities From Link – the linked solution
must have the exact same geometry as the current simulation
• Demagnetization Option: Allows the permanent
demagnetization to be determined from the Nonlinear B-H
curve or to use demagnetized values From Link - where the
linked solution must the option “Compute Data for Link -
Demagnetized operating points” checked and must have the
exact same geometry
• Import Mesh: Allows the initial mesh to be imported from
another solution – the linked solution must have the exact
same geometry as the current simulation. Setup Link must be
defined when selecting From Link or Import Mesh.
© 2013 ANSYS, Inc. May 21, 2013 16 Release 14.5
g. Solution Process
Magnetostatic Solution Process
– The solution process is very automated.
Once problem is completely defined,
Maxwell steps through several stages of
solution process as shown in diagram
– A Solution process can be launched from
the menu item Maxwell 3D/2D 
Analyze All
Initial Setup
Adaptive Solution
Nonlinear Convergence
(Changing permeability)
Refine Mesh
Converged or Number
of Passes
Stop Field Solution
Calculate Parameters
Solution Convergence ?
Force/Torque Calculation
NoYes
© 2013 ANSYS, Inc. May 21, 2013 17 Release 14.5
B. Eddy Current Solver
Eddy Current Solver
– Eddy current solver computes steady-state, time-varying (AC) magnetic fields at
a given frequency
– This is a frequency domain solution and assumes frequency of the pulsating
fields to be same throughout the domain
– 3D Eddy Current Solver is a full wave solver and solves for displacement currents
– The source of the AC magnetic field can be a Sinusoidal AC current in conductors
or time-varying external magnetic fields represented by external boundary
conditions.
– Eddy Current solver utilizes adaptive mesh refinement technique to achieve best
mesh required to meet defined accuracy level
Eddy Current Equations
– Following equations are solved with Eddy Current solver
HjH
j  
 








 1
Maxwell 3D
HjH
j  
 








 1
Maxwell 2D
© 2013 ANSYS, Inc. May 21, 2013 18 Release 14.5
a. Selecting the Eddy Current Problem
Selecting the Eddy Current Solver
– By default, any newly created design will be set as a Magnetostatic problem
– Specify Eddy Current Solver by selecting the menu item Maxwell 2D/3D 
Solution Type
– In Solution type window, select Magnetic> Eddy Current and press OK
Maxwell 3D Maxwell 2D
© 2013 ANSYS, Inc. May 21, 2013 19 Release 14.5
b. Material Definition
Eddy Current Material Properties
– In Eddy Current simulations, the following parameters may be defined for a
material:
Bulk Conductivity:
• Used in determining the current distribution in current
carrying conductors and eddy currents from resulting
magnetic field.
• Can be Simple or Anisotropic
Dielectric Loss Tangent:
• Defines the ratio of imaginary and real permittivities.
• Can be Simple or Anisotropic
Magnetic Loss Tangent:
• Defines the ratio of imaginary and real permeabilities.
• Can be Simple or Anisotropic
Relative Permittivity:
• Relative Permittivity effects solution when displacement currents are considered in an object.
• Relative Permittivity can be Simple or anisotropic
Relative Permeability :
• Relative Permeability along with the Bulk Conductivity determine the time-varying magnetic
properties of the material.
• Relative Permeability can be Simple and Anisotropic. In Maxwell 2D, nonlinear permeability is
supported by obtaining a linearized permeability for each element from non-linear curve.
Solution is still assumed to be linear.
© 2013 ANSYS, Inc. May 21, 2013 20 Release 14.5
…Material Definition
Eddy Current Material Properties
Core Loss Type:
• Enables users to define Core Loss properties based on selected Core Loss Type
• Core Loss Type can be either Electrical Steel or Power ferrite
• Core Loss Coefficients will change according to selected Core Loss type
y
m
x
mv BfCp 
5.122
)()()( memcmhv fBKfBKBfKp 
Core Loss Coefficient Calculations:
• Maxwell provides tools to evaluate core loss coefficients based on core loss data provided by
users
• Users can select tab at the bottom of View/Edit Material window and select the option
“Calculate Properties for”
For Electrical Steel For Power Ferrites
© 2013 ANSYS, Inc. May 21, 2013 21 Release 14.5
…Material Definition
Eddy Current Material Properties
Core Loss at One Frequency:
• Selecting the option Calculate Properties for “Core Loss at One Frequency” enables users to
input B-P Curve for a defined frequency point
• This option is available only for Electrical Steel
• Using specified B-P Curve, K1 and K2 are obtained by minimizing quadratic form
Where, i is the each entity in defined B-P Curve
• Eddy Current coefficient, kc is evaluated as
min)]([),( 25.1
2
2
121   mimi
i
vi BKBKPKKerr


2
2 d
kc 
Where, σ is the conductivity and d is the thickness of
one lamination sheets.
0
2
01
f
fkK
k c
h


• Hysteresis Loss coefficient (kh)and Excessive
Loss Coefficients (ke) are evaluated from K1, K2
and kc
5.1
0
2
f
K
kh 
© 2013 ANSYS, Inc. May 21, 2013 22 Release 14.5
…Material Definition
Eddy Current Material Properties
Core Loss versus Frequency:
• Selecting the option Calculate Properties for “Core Loss versus Frequency” enables users to
input B-P Curve for multiple frequency points
• For Electrical Steel
• kh,kc and ke are obtained by minimizing quadratic form
Where, m is number of curves added and ni is number of points defined in ith curve
• For Power Ferrites
• Core loss coefficients Cm, x and y are obtained by minimizing the quadratic form
Where,
min)]([),,( 25.15.1222
1 1
  
mijiemijicmijih
m
i
n
j
vijech BfkBfkBfkpkkkerr
i
min))]log()log(()[log(),,(
1 1
2
  
m
i
n
j
mijivij
i
Byfxcpyxcerr
)log( mCc 
© 2013 ANSYS, Inc. May 21, 2013 23 Release 14.5
c. Boundary Conditions
Boundary Types
– All the boundaries which were discussed with the Magnetostatic solver are also
applicable for Eddy Current Solver
– In addition, two other boundaries can be defined
Impedance Boundary (2D & 3D):
• Allows users to simulate effect of induced currents without
explicitly solving and having to mesh for the skin depth
• Equivalent calculations are done on surface elements of the
conductor without any flux computation for inside region of
conductor
• Can be suitably used where skill depth of the conductor is two
orders of magnitude smaller than its dimensions
Radiation Boundary (3D):
• To simulate problems that allow fields to radiate infinitely far into
space
• The system absorbs the field at the radiation boundary, essentially
ballooning the boundary infinitely far away from the structure
Surface Loss Density on
Impedance Boundary
Poynting Vectors on
Radiation Boundary
© 2013 ANSYS, Inc. May 21, 2013 24 Release 14.5
d. Excitations
Excitations
– Eddy Current solvers allows two type of excitations, Current and Current Density
Current :
• Defines total peak current in Amp-turns through the conductor and
phase
• Can be assigned to the conductor faces that lie on boundary of
simulation domain or sheets that lie completely inside a conductor with
a closed conduction path.
• Conductor can be defined as Solid or Stranded
• Induced eddy effects are not computed for stranded conductors
Current Density:
• Used to define known current density and phase throughout an object.
• In 3D, this definition should be accompanied with Current Density
Terminal definition
• Current Density defined using X,Y and Z components of selected CS
Parallel Current (2D only):
• Used to define total AC current in a parallel conduction path consisting
of at least two conductors
• For Parallel Solid Conductors, total current split will be based on field
solutions including eddy effects
• For Parallel Stranded Conductors, total current split will be based on
relative areas of selected conductors
© 2013 ANSYS, Inc. May 21, 2013 25 Release 14.5
…Excitations
Setting Eddy Effects (Calculating Eddy Currents)
– Eddy Effects can be set from the menu item Maxwell 3D/2D  Excitations 
Set Eddy Effects
– Induced eddy current calculations can be enabled or disabled for an object
– Displacement current calculations can also be set for the 3D eddy current solver
Setting Core Loss
– Core Loss calculations can be assigned from the menu item Maxwell 3D/2D 
Excitations  Set Core Loss
– If Core Loss is enabled for an object, Eddy effects should be disabled for that
object since the Core loss calculation includes Eddy losses
– Core Loss properties must be defined for the material as discussed earlier
Maxwell 3D Maxwell 2D
© 2013 ANSYS, Inc. May 21, 2013 26 Release 14.5
e. Parameters
Parameters
– All the parameters that are available with Magnetostatic Solver are also
available with Eddy Current Solver
– A parameter cane added by selecting the required object and selecting menu
item Maxwell 3D/2D  Parameters  Assign
Force:
• Calculates force acting on assigned object
• Force can be Virtual or Lorentz
• Lorentz can not be used for magnetic material
Torque:
• Calculates torque on assigned object
• Torque can be Virtual or Lorentz
Matrix:
• Calculates Inductance, resistance matrix
• Reported resistance values are AC resistances which include
skin and proximity effects
• Postprocessing option is not available with Eddy Current
matrix
© 2013 ANSYS, Inc. May 21, 2013 27 Release 14.5
f. Analysis Setup
Solution Setup
– A Solution Setup can be added from the menu item Maxwell 3D/2D  Analysis
Setup  Add Solution Setup
– Options on the General and Convergence tab of the Solve Setup window are the
same as the options with Magnetostatic solver.
Solver Tab
• Adaptive Frequency: Defines the frequency at which the mesh is
constructed and adapted, and at which solution is obtained
• Enable Iterative Solve: Enables ICCG solvers (Direct is the default).
• Use higher order shape functions: Enables higher order option
gains better accuracy for eddy current regions.
• Import Mesh: Allows the initial mesh to be imported from another
solution – the linked solution must have the exact same geometry
as the current simulation
Frequency Sweep Tab
• Sweep Setup (Type, Start, Stop, Step): Enables to define frequency
sweep range and points
• Save Fields: Saves the fields for defined frequency Sweep
• Add to List >>: Places sweep definition in the Sweep List (the
Sweep List is displayed in the right panel).
• Edit any entries in the Sweep List to adjust solution frequencies or
whether to save fields at specific frequencies in the list.
© 2013 ANSYS, Inc. May 21, 2013 28 Release 14.5
g. Solution Process
Eddy Current Solution Process
– Like the Magnetostatic Solver, the solution process in the Eddy Current solver is
automated as shown in diagram below
– A Solution process can be launched from the menu item Maxwell 3D/2D 
Analyze All Initial Setup
Adaptive Solution
Refine Mesh
Converged or
Number of Passes
Stop Field Solution
Calculate Parameters
Solution Convergence ?
NoYes
Frequency Sweep?
Done
Yes
No

More Related Content

What's hot

07.flash memory technology
07.flash memory technology07.flash memory technology
07.flash memory technology
ruchiusha
 
Variables in matlab
Variables in matlabVariables in matlab
Variables in matlab
TUOS-Sam
 

What's hot (13)

LaTex tutorial with Texstudio
LaTex tutorial with TexstudioLaTex tutorial with Texstudio
LaTex tutorial with Texstudio
 
SRVCC (Single Radio Voice Call Continuity) in VoLTE & Comparison with CSFB
SRVCC (Single Radio Voice Call Continuity) in VoLTE & Comparison with CSFBSRVCC (Single Radio Voice Call Continuity) in VoLTE & Comparison with CSFB
SRVCC (Single Radio Voice Call Continuity) in VoLTE & Comparison with CSFB
 
07.flash memory technology
07.flash memory technology07.flash memory technology
07.flash memory technology
 
ZTE_NR8000_Overview.pdf
ZTE_NR8000_Overview.pdfZTE_NR8000_Overview.pdf
ZTE_NR8000_Overview.pdf
 
Gsm rf-optimization
Gsm rf-optimizationGsm rf-optimization
Gsm rf-optimization
 
Variables in matlab
Variables in matlabVariables in matlab
Variables in matlab
 
Digital Control in Power Electronics.pdf
Digital Control in Power Electronics.pdfDigital Control in Power Electronics.pdf
Digital Control in Power Electronics.pdf
 
Lte ho parameters trial_01262011
Lte ho parameters trial_01262011Lte ho parameters trial_01262011
Lte ho parameters trial_01262011
 
Rf planning for lte using atoll v1
Rf planning for lte using atoll v1Rf planning for lte using atoll v1
Rf planning for lte using atoll v1
 
UMTS/LTE/EPC Call Flows for CSFB
UMTS/LTE/EPC Call Flows for CSFBUMTS/LTE/EPC Call Flows for CSFB
UMTS/LTE/EPC Call Flows for CSFB
 
305090798 04-basic-parameter-planning-rules-v1-1
305090798 04-basic-parameter-planning-rules-v1-1305090798 04-basic-parameter-planning-rules-v1-1
305090798 04-basic-parameter-planning-rules-v1-1
 
GSM Cell planning and frequency reuse
GSM Cell planning and frequency reuseGSM Cell planning and frequency reuse
GSM Cell planning and frequency reuse
 
Gsm physical and-logical_channels
Gsm physical and-logical_channelsGsm physical and-logical_channels
Gsm physical and-logical_channels
 

Similar to Maxwell v16 l03_static_magnetic_solvers

Fluent Introduction - Some Best Practice_._.pptx
Fluent Introduction - Some Best Practice_._.pptxFluent Introduction - Some Best Practice_._.pptx
Fluent Introduction - Some Best Practice_._.pptx
LibinAbrahamKonattu
 
Unit 2 - Meshing Techniques.pptx
Unit 2 - Meshing Techniques.pptxUnit 2 - Meshing Techniques.pptx
Unit 2 - Meshing Techniques.pptx
SMHC41Shivam
 
Voltage_Stability_Analysis_With DG NEW (1).pptx
Voltage_Stability_Analysis_With DG NEW (1).pptxVoltage_Stability_Analysis_With DG NEW (1).pptx
Voltage_Stability_Analysis_With DG NEW (1).pptx
rameshss
 

Similar to Maxwell v16 l03_static_magnetic_solvers (20)

Tutorial 2
Tutorial 2Tutorial 2
Tutorial 2
 
12 l1-harmonic methodology
12 l1-harmonic methodology12 l1-harmonic methodology
12 l1-harmonic methodology
 
ABAQUS LEC.ppt
ABAQUS LEC.pptABAQUS LEC.ppt
ABAQUS LEC.ppt
 
11 (l)random vibrations methodology
11 (l)random vibrations  methodology11 (l)random vibrations  methodology
11 (l)random vibrations methodology
 
Distributed generation placement
Distributed generation placementDistributed generation placement
Distributed generation placement
 
Meshing Techniques.pptx
Meshing Techniques.pptxMeshing Techniques.pptx
Meshing Techniques.pptx
 
FEA Report
FEA ReportFEA Report
FEA Report
 
Fluent Introduction - Some Best Practice_._.pptx
Fluent Introduction - Some Best Practice_._.pptxFluent Introduction - Some Best Practice_._.pptx
Fluent Introduction - Some Best Practice_._.pptx
 
ANSYS Emag 8.0 Capabilities.ppt
ANSYS Emag 8.0 Capabilities.pptANSYS Emag 8.0 Capabilities.ppt
ANSYS Emag 8.0 Capabilities.ppt
 
EDM_SEMINAR.pptx
EDM_SEMINAR.pptxEDM_SEMINAR.pptx
EDM_SEMINAR.pptx
 
12-edicon20185G Designing a Narrowband 28 GHz Band Pass Filter.pdf
12-edicon20185G Designing a Narrowband 28 GHz Band Pass Filter.pdf12-edicon20185G Designing a Narrowband 28 GHz Band Pass Filter.pdf
12-edicon20185G Designing a Narrowband 28 GHz Band Pass Filter.pdf
 
Steady state CFD analysis of C-D nozzle
Steady state CFD analysis of C-D nozzle Steady state CFD analysis of C-D nozzle
Steady state CFD analysis of C-D nozzle
 
Cetc11 - Wireless Magnetic Based Sensor System For Vehicles Classification
Cetc11 - Wireless Magnetic Based Sensor System  For Vehicles ClassificationCetc11 - Wireless Magnetic Based Sensor System  For Vehicles Classification
Cetc11 - Wireless Magnetic Based Sensor System For Vehicles Classification
 
5 mesh control (2)
5 mesh control (2)5 mesh control (2)
5 mesh control (2)
 
Fem
FemFem
Fem
 
Impedance matching in awr
Impedance matching in awrImpedance matching in awr
Impedance matching in awr
 
Unit 2 - Meshing Techniques.pptx
Unit 2 - Meshing Techniques.pptxUnit 2 - Meshing Techniques.pptx
Unit 2 - Meshing Techniques.pptx
 
Modeling of twain Tunnel water conveyance
Modeling of twain Tunnel water conveyanceModeling of twain Tunnel water conveyance
Modeling of twain Tunnel water conveyance
 
Tutorial_01_Quick_Start.pdf
Tutorial_01_Quick_Start.pdfTutorial_01_Quick_Start.pdf
Tutorial_01_Quick_Start.pdf
 
Voltage_Stability_Analysis_With DG NEW (1).pptx
Voltage_Stability_Analysis_With DG NEW (1).pptxVoltage_Stability_Analysis_With DG NEW (1).pptx
Voltage_Stability_Analysis_With DG NEW (1).pptx
 

More from Kadiro Abdelkader (15)

Access-2007
Access-2007Access-2007
Access-2007
 
Bok 3 a978-94-007-0202-8
Bok 3 a978-94-007-0202-8Bok 3 a978-94-007-0202-8
Bok 3 a978-94-007-0202-8
 
Access tutorial
Access tutorialAccess tutorial
Access tutorial
 
Access 2007
Access 2007Access 2007
Access 2007
 
29da4aac5068b8bb36121391799925fa original
29da4aac5068b8bb36121391799925fa original29da4aac5068b8bb36121391799925fa original
29da4aac5068b8bb36121391799925fa original
 
Elebda3.net 818
Elebda3.net 818Elebda3.net 818
Elebda3.net 818
 
Elebda3.net 1553
Elebda3.net 1553Elebda3.net 1553
Elebda3.net 1553
 
Elebda3.net 5832
Elebda3.net 5832Elebda3.net 5832
Elebda3.net 5832
 
Elebda3.net 6680
Elebda3.net 6680Elebda3.net 6680
Elebda3.net 6680
 
Pk0306 tsoft_5544
Pk0306  tsoft_5544Pk0306  tsoft_5544
Pk0306 tsoft_5544
 
Requetes
RequetesRequetes
Requetes
 
Présentation les traitements thermiques
Présentation les traitements thermiquesPrésentation les traitements thermiques
Présentation les traitements thermiques
 
Magnetisme induction
Magnetisme inductionMagnetisme induction
Magnetisme induction
 
Zhe huangm sc
Zhe huangm scZhe huangm sc
Zhe huangm sc
 
5006 2
5006 25006 2
5006 2
 

Recently uploaded

Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
jaanualu31
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ssuser89054b
 

Recently uploaded (20)

S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptxS1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.ppt
 
Learn the concepts of Thermodynamics on Magic Marks
Learn the concepts of Thermodynamics on Magic MarksLearn the concepts of Thermodynamics on Magic Marks
Learn the concepts of Thermodynamics on Magic Marks
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Computer Networks Basics of Network Devices
Computer Networks  Basics of Network DevicesComputer Networks  Basics of Network Devices
Computer Networks Basics of Network Devices
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 

Maxwell v16 l03_static_magnetic_solvers

  • 1. © 2013 ANSYS, Inc. May 21, 2013 1 Release 14.5 Lecture 3: Static Magnetic Solvers ANSYS Maxwell V16 Training Manual
  • 2. © 2013 ANSYS, Inc. May 21, 2013 2 Release 14.5 A. Magnetostatic Solver a. Selecting the Magnetostatic Solver b. Material Definition c. Boundary Conditions d. Excitations e. Parameters f. Analysis Setup g. Solution Process B. Eddy Current Solver a. Selecting the Eddy Current Solver b. Material Definition c. Boundary Conditions d. Excitations e. Parameters f. Analysis Setup g. Solution Process Content
  • 3. © 2013 ANSYS, Inc. May 21, 2013 3 Release 14.5 A. Magnetostatic Solver Magnetostatic Solver – In the Magnetostatic Solver, a static magnetic field is solved resulting from a DC current flowing through a coil or due to a permanent magnet – The Electric field inside the current carrying coil is completely decoupled from magnetic field – Losses are only due to Ohmic losses in current carrying conductors – The Magnetostatic solver utilizes an automatic adaptive mesh refinement technique to achieve an accurate and efficient mesh required to meet defined accuracy level (energy error). Magnetostatic Equations – Following two Maxwell’s equations are solved with Magnetostatic solver pr MHMH(μB B JH    000 ) 0         )),((1),( 0 yxAyxJ z r z  Maxwell 3D Maxwell 2D
  • 4. © 2013 ANSYS, Inc. May 21, 2013 4 Release 14.5 a. Selecting the Magnetostatic Problem Selecting the Magnetostatic Solver – By default, any newly created design will be set as a Magnetostatic problem – Specify the Magnetostatic Solver by selecting the menu item Maxwell 2D/3D  Solution Type – In Solution type window, select Magnetic> Magnetostatic and press OK Maxwell 3D Maxwell 2D
  • 5. © 2013 ANSYS, Inc. May 21, 2013 5 Release 14.5 b. Material Definition Magnetostatic Material Properties – In a Magnetostatic simulation, the following parameters may be defined for a material (by clicking on the pull-down menu under Type and Value) Magnetic Coercivity: • Used to define permanent magnetization of magnetic materials. • Requires magnitude and direction specification. • Direction specified is with respect to Orientation CS of bodies to which material is assigned Composition: • Can be Solid or Lamination • Setting Composition to Lamination creates an anisotropic magnetization effect. Relative Permeability: • Permeability (µ) is defined as µ0*µr • Relative permeability(µr) along with the Magnetic Coercivity determine the magnetic properties of the material. • Relative permeability can be Simple(linear µr) or Nonlinear(BH Curve) or/and anisotropic Bulk Conductivity: • Used to determine the current distribution in current carrying conductors • Does not have any impact on magnetic part of analysis • Can be Simple or Anisotropic
  • 6. © 2013 ANSYS, Inc. May 21, 2013 6 Release 14.5 c. Boundary Conditions Assigning Boundary Conditions in 3D – Boundary conditions define behavior of the magnetic field at the interfaces or the edges of the problem region – A boundary can be assigned to a face from menu item Maxwell 3D  Boundaries  Assign and select the required boundary assignment Boundary Types(3D) NaturalNeumann Default (No Boundary Assigned): When no boundary is specified for a surface, following two treatments are assigned based on the surface position • Natural: for the boundaries on the interface between objects. H Field is continuous across the boundary. • Neumann: For exterior boundaries of solution domain. H Field is tangential to the boundary and flux cannot cross it. H Vectors
  • 7. © 2013 ANSYS, Inc. May 21, 2013 7 Release 14.5 …Boundary Conditions Boundary Types (3D) Tangential H-Field: • Useful to assign external field. • Tangential H field is applied using U and V components • Can be applied to external boundaries of the domain Insulating: • Same as Neumann, except that current cannot cross the boundary. • Can be used to insulate two conductors which are in contact with each other J Vectors without insulating boundary between plates J Vectors with insulating boundary defined between plates Zero Tangential H-Field: • Useful to assign external field. • H field is normal to assigned surface • Can be applied to external boundaries of the domain H Vectors on Zero Tangential H field boundary H Vectors on Tangential H field boundary
  • 8. © 2013 ANSYS, Inc. May 21, 2013 8 Release 14.5 …Boundary Conditions Boundary Types (2D) Note: In 2D, no default boundary is assigned to the boundaries of the simulation region. Users have to specify the behavior of simulation boundaries by assigning either Balloon or vector potential boundary. Vector Potential: • Sets the specified value of magnetic vector potential on the boundary. • Used to model Magnetically isolated structures. Balloon: • Models the region outside drawing space as being infinitely large. • Magnetic flux lines are neither tangential nor normal to the boundary Flux lines with zero vector potential on outer boundary Flux lines with Balloon on outer boundary
  • 9. © 2013 ANSYS, Inc. May 21, 2013 9 Release 14.5 …Boundary Conditions Boundary Types (2D & 3D): Symmetry Boundary: • Enable users to model only part of a structure, which reduces the size or complexity of design, thereby shortening the solution time. • Applied to external boundaries of domain. Symmetry Odd: Same as default Boundary (Flux Tangential) Symmetry Even: Same as Zero Tangential H-Field boundary (Flux Normal) 1/8th Model Master/Slave : • Enable users to model only one period of a periodic structure, which reduces the design size • This boundary condition matches the magnetic field at the slave boundary to the field at the master boundary based on U and V vectors defined. Master = Slave Master = -Slave 1/4th Model
  • 10. © 2013 ANSYS, Inc. May 21, 2013 10 Release 14.5 d. Excitations Assigning Excitations – Excitations can be assigned from the menu item Maxwell 2D/3D  Excitations  Assign Excitation (2D & 3D) Current : • Defines total current in Amp-turns through the conductor • Can be assigned to the conductor faces that lie on boundary of simulation domain or sheets that lie completely inside the conductor • Conductor can be defined as Solid or Stranded Incorrect Excitation definitions Correctly defined Excitations Current Density: • Used to define a known current density throughout an object. • In 3D, this definition should be accompanied with Current Density Terminal definition • Current Density defined using X,Y and Z components of selected CS
  • 11. © 2013 ANSYS, Inc. May 21, 2013 11 Release 14.5 …Excitations Excitation (3D) Voltage : • Used in conjunction with material conductivity to define current through a solid conductor • Can only be assigned to faces or sheets that lie on the boundary of simulation domain Voltage Drop: • Similar to the voltage definition • Can only be assigned to sheets which lie completely inside the conduction path Current Density Terminal: • Required to be defined if Current Density is defined • Can be assigned to any 2D sheet which lies completely inside the conductor or Conductor faces that lie on the boundary of simulation domain
  • 12. © 2013 ANSYS, Inc. May 21, 2013 12 Release 14.5 e. Parameters Parameters – Three calculation parameters can be assigned for magnetostatic solver which are computed using magnetic field solution – A parameter can be added by selecting the required object and selecting menu item Maxwell 3D/2D  Parameters  Assign Force: • Calculates force acting on assigned object • Force can be Virtual or Lorentz • Lorentz can not be used for magnetic material Torque: • Calculates torque on assigned object • Torque can be Virtual or Lorentz Matrix: • Calculates Inductance, resistance matrix • Calculated matrix can be postprocessed based on defined groups
  • 13. © 2013 ANSYS, Inc. May 21, 2013 13 Release 14.5 f. Analysis Setup Solution Setup – The solution setup defines the parameters used for solving the simulation – A Solution Setup can be added from the menu item Maxwell 3D/2D  Analysis Setup  Add Solution Setup General Tab • Name: sets the Name of the setup. Users can have multiple setups in the same design by repeating the procedure • Maximum Number of Passes: Defines a limit to the number of adaptively refined passes that the solver performs • Percent Error: Error goal for both Error Energy and Delta Energy. • Solve Fields Only: Ignores any defined parameters if checked. • Solve Matrix: Provides the options of calculating the matrix after the last solved pass or only if the solution converges. Convergence Tab • Refinement Per Pass: Defines the number of tetrahedral elements added during mesh refinement as a percentage of the previous pass • Minimum Number of Passes: Defines the minimum number of adaptive passes before the solution stops - if there is a conflict, this value is over-ridden by Maximum Number of Passes • Minimum Converged Passes: Defines the minimum number of converged adaptive passed before solution is stopped
  • 14. © 2013 ANSYS, Inc. May 21, 2013 14 Release 14.5 …Analysis Setup Solution Setup Expression Cache Tab: • Enables users to define Output calculations at each adaptive pass or set an additional convergence criteria based on added parameters. • Solution Setup should be completely defined first to enable adding Expression Cache variables • Clicking on Add button enables users to define Output quantities which can be any defined parameters or derived quantities from Field Calculator • Selecting the tab under Convergence will enable users to add the selected quantity as a convergence criteria • Users can define the permissible change in output quantity in percentile or absolute value • Output quantity will be evaluated at each Adaptive pass. • If the change in defined output is less than specified value, the solution is considered to be converged provided that energy is already converged.
  • 15. © 2013 ANSYS, Inc. May 21, 2013 15 Release 14.5 …Analysis Setup Solution Setup Solver Tab • Nonlinear Residual: Defines how precisely the nonlinear solution must define the B-H nonlinear operating points • Enable Iterative Solver: Enables ICCG solvers (Direct is the default). • Permeability Option: Allows nonlinear B-H operating points either to be calculated by the solver from Nonlinear B-H curve or to use frozen permeabilities From Link – the linked solution must have the exact same geometry as the current simulation • Demagnetization Option: Allows the permanent demagnetization to be determined from the Nonlinear B-H curve or to use demagnetized values From Link - where the linked solution must the option “Compute Data for Link - Demagnetized operating points” checked and must have the exact same geometry • Import Mesh: Allows the initial mesh to be imported from another solution – the linked solution must have the exact same geometry as the current simulation. Setup Link must be defined when selecting From Link or Import Mesh.
  • 16. © 2013 ANSYS, Inc. May 21, 2013 16 Release 14.5 g. Solution Process Magnetostatic Solution Process – The solution process is very automated. Once problem is completely defined, Maxwell steps through several stages of solution process as shown in diagram – A Solution process can be launched from the menu item Maxwell 3D/2D  Analyze All Initial Setup Adaptive Solution Nonlinear Convergence (Changing permeability) Refine Mesh Converged or Number of Passes Stop Field Solution Calculate Parameters Solution Convergence ? Force/Torque Calculation NoYes
  • 17. © 2013 ANSYS, Inc. May 21, 2013 17 Release 14.5 B. Eddy Current Solver Eddy Current Solver – Eddy current solver computes steady-state, time-varying (AC) magnetic fields at a given frequency – This is a frequency domain solution and assumes frequency of the pulsating fields to be same throughout the domain – 3D Eddy Current Solver is a full wave solver and solves for displacement currents – The source of the AC magnetic field can be a Sinusoidal AC current in conductors or time-varying external magnetic fields represented by external boundary conditions. – Eddy Current solver utilizes adaptive mesh refinement technique to achieve best mesh required to meet defined accuracy level Eddy Current Equations – Following equations are solved with Eddy Current solver HjH j              1 Maxwell 3D HjH j              1 Maxwell 2D
  • 18. © 2013 ANSYS, Inc. May 21, 2013 18 Release 14.5 a. Selecting the Eddy Current Problem Selecting the Eddy Current Solver – By default, any newly created design will be set as a Magnetostatic problem – Specify Eddy Current Solver by selecting the menu item Maxwell 2D/3D  Solution Type – In Solution type window, select Magnetic> Eddy Current and press OK Maxwell 3D Maxwell 2D
  • 19. © 2013 ANSYS, Inc. May 21, 2013 19 Release 14.5 b. Material Definition Eddy Current Material Properties – In Eddy Current simulations, the following parameters may be defined for a material: Bulk Conductivity: • Used in determining the current distribution in current carrying conductors and eddy currents from resulting magnetic field. • Can be Simple or Anisotropic Dielectric Loss Tangent: • Defines the ratio of imaginary and real permittivities. • Can be Simple or Anisotropic Magnetic Loss Tangent: • Defines the ratio of imaginary and real permeabilities. • Can be Simple or Anisotropic Relative Permittivity: • Relative Permittivity effects solution when displacement currents are considered in an object. • Relative Permittivity can be Simple or anisotropic Relative Permeability : • Relative Permeability along with the Bulk Conductivity determine the time-varying magnetic properties of the material. • Relative Permeability can be Simple and Anisotropic. In Maxwell 2D, nonlinear permeability is supported by obtaining a linearized permeability for each element from non-linear curve. Solution is still assumed to be linear.
  • 20. © 2013 ANSYS, Inc. May 21, 2013 20 Release 14.5 …Material Definition Eddy Current Material Properties Core Loss Type: • Enables users to define Core Loss properties based on selected Core Loss Type • Core Loss Type can be either Electrical Steel or Power ferrite • Core Loss Coefficients will change according to selected Core Loss type y m x mv BfCp  5.122 )()()( memcmhv fBKfBKBfKp  Core Loss Coefficient Calculations: • Maxwell provides tools to evaluate core loss coefficients based on core loss data provided by users • Users can select tab at the bottom of View/Edit Material window and select the option “Calculate Properties for” For Electrical Steel For Power Ferrites
  • 21. © 2013 ANSYS, Inc. May 21, 2013 21 Release 14.5 …Material Definition Eddy Current Material Properties Core Loss at One Frequency: • Selecting the option Calculate Properties for “Core Loss at One Frequency” enables users to input B-P Curve for a defined frequency point • This option is available only for Electrical Steel • Using specified B-P Curve, K1 and K2 are obtained by minimizing quadratic form Where, i is the each entity in defined B-P Curve • Eddy Current coefficient, kc is evaluated as min)]([),( 25.1 2 2 121   mimi i vi BKBKPKKerr   2 2 d kc  Where, σ is the conductivity and d is the thickness of one lamination sheets. 0 2 01 f fkK k c h   • Hysteresis Loss coefficient (kh)and Excessive Loss Coefficients (ke) are evaluated from K1, K2 and kc 5.1 0 2 f K kh 
  • 22. © 2013 ANSYS, Inc. May 21, 2013 22 Release 14.5 …Material Definition Eddy Current Material Properties Core Loss versus Frequency: • Selecting the option Calculate Properties for “Core Loss versus Frequency” enables users to input B-P Curve for multiple frequency points • For Electrical Steel • kh,kc and ke are obtained by minimizing quadratic form Where, m is number of curves added and ni is number of points defined in ith curve • For Power Ferrites • Core loss coefficients Cm, x and y are obtained by minimizing the quadratic form Where, min)]([),,( 25.15.1222 1 1    mijiemijicmijih m i n j vijech BfkBfkBfkpkkkerr i min))]log()log(()[log(),,( 1 1 2    m i n j mijivij i Byfxcpyxcerr )log( mCc 
  • 23. © 2013 ANSYS, Inc. May 21, 2013 23 Release 14.5 c. Boundary Conditions Boundary Types – All the boundaries which were discussed with the Magnetostatic solver are also applicable for Eddy Current Solver – In addition, two other boundaries can be defined Impedance Boundary (2D & 3D): • Allows users to simulate effect of induced currents without explicitly solving and having to mesh for the skin depth • Equivalent calculations are done on surface elements of the conductor without any flux computation for inside region of conductor • Can be suitably used where skill depth of the conductor is two orders of magnitude smaller than its dimensions Radiation Boundary (3D): • To simulate problems that allow fields to radiate infinitely far into space • The system absorbs the field at the radiation boundary, essentially ballooning the boundary infinitely far away from the structure Surface Loss Density on Impedance Boundary Poynting Vectors on Radiation Boundary
  • 24. © 2013 ANSYS, Inc. May 21, 2013 24 Release 14.5 d. Excitations Excitations – Eddy Current solvers allows two type of excitations, Current and Current Density Current : • Defines total peak current in Amp-turns through the conductor and phase • Can be assigned to the conductor faces that lie on boundary of simulation domain or sheets that lie completely inside a conductor with a closed conduction path. • Conductor can be defined as Solid or Stranded • Induced eddy effects are not computed for stranded conductors Current Density: • Used to define known current density and phase throughout an object. • In 3D, this definition should be accompanied with Current Density Terminal definition • Current Density defined using X,Y and Z components of selected CS Parallel Current (2D only): • Used to define total AC current in a parallel conduction path consisting of at least two conductors • For Parallel Solid Conductors, total current split will be based on field solutions including eddy effects • For Parallel Stranded Conductors, total current split will be based on relative areas of selected conductors
  • 25. © 2013 ANSYS, Inc. May 21, 2013 25 Release 14.5 …Excitations Setting Eddy Effects (Calculating Eddy Currents) – Eddy Effects can be set from the menu item Maxwell 3D/2D  Excitations  Set Eddy Effects – Induced eddy current calculations can be enabled or disabled for an object – Displacement current calculations can also be set for the 3D eddy current solver Setting Core Loss – Core Loss calculations can be assigned from the menu item Maxwell 3D/2D  Excitations  Set Core Loss – If Core Loss is enabled for an object, Eddy effects should be disabled for that object since the Core loss calculation includes Eddy losses – Core Loss properties must be defined for the material as discussed earlier Maxwell 3D Maxwell 2D
  • 26. © 2013 ANSYS, Inc. May 21, 2013 26 Release 14.5 e. Parameters Parameters – All the parameters that are available with Magnetostatic Solver are also available with Eddy Current Solver – A parameter cane added by selecting the required object and selecting menu item Maxwell 3D/2D  Parameters  Assign Force: • Calculates force acting on assigned object • Force can be Virtual or Lorentz • Lorentz can not be used for magnetic material Torque: • Calculates torque on assigned object • Torque can be Virtual or Lorentz Matrix: • Calculates Inductance, resistance matrix • Reported resistance values are AC resistances which include skin and proximity effects • Postprocessing option is not available with Eddy Current matrix
  • 27. © 2013 ANSYS, Inc. May 21, 2013 27 Release 14.5 f. Analysis Setup Solution Setup – A Solution Setup can be added from the menu item Maxwell 3D/2D  Analysis Setup  Add Solution Setup – Options on the General and Convergence tab of the Solve Setup window are the same as the options with Magnetostatic solver. Solver Tab • Adaptive Frequency: Defines the frequency at which the mesh is constructed and adapted, and at which solution is obtained • Enable Iterative Solve: Enables ICCG solvers (Direct is the default). • Use higher order shape functions: Enables higher order option gains better accuracy for eddy current regions. • Import Mesh: Allows the initial mesh to be imported from another solution – the linked solution must have the exact same geometry as the current simulation Frequency Sweep Tab • Sweep Setup (Type, Start, Stop, Step): Enables to define frequency sweep range and points • Save Fields: Saves the fields for defined frequency Sweep • Add to List >>: Places sweep definition in the Sweep List (the Sweep List is displayed in the right panel). • Edit any entries in the Sweep List to adjust solution frequencies or whether to save fields at specific frequencies in the list.
  • 28. © 2013 ANSYS, Inc. May 21, 2013 28 Release 14.5 g. Solution Process Eddy Current Solution Process – Like the Magnetostatic Solver, the solution process in the Eddy Current solver is automated as shown in diagram below – A Solution process can be launched from the menu item Maxwell 3D/2D  Analyze All Initial Setup Adaptive Solution Refine Mesh Converged or Number of Passes Stop Field Solution Calculate Parameters Solution Convergence ? NoYes Frequency Sweep? Done Yes No