WATERLOO MEMBRANE
SAMPLER (WMS)
INSTALLATION METHODOLOGY
SCOPE
This method is intended for the passive sampling of Volatile Organic Compounds
(VOCs) in ambient air and soil gas - using Waterloo membrane samplers (WMS’).
This method is a guide on the installation process for WMS’ and does not purport to
address all of the aspects of site assessment such as implementation of sampling
pattern, sampling density/frequency, data interpretation, modelling, outside influences
or technical issues.
PRINCIPLE
VOC’s in a gaseous phase move across a permeable membrane and sorb to absorbent
medium within a glass vial. The membrane is made of poly-dimethyl siloxane (PDMS)
which has known permeability values for a range of compounds. The movement
of VOC’s across the PDMS membrane is controlled by the molecular mass of the
individual organic compounds and the surface area of the membrane which is available
for the VOC diffusion.
REFERENCES
a.	 ASTM D7758-11 Passive Soil Gas Sampling in the Vadose Zone for Source
Identification, Spatial Variability Assessment, Monitoring, and Vapour Intrusion
Evaluations, 2011.
b.	 ASTM D5314 – 92), Standard Guide for Soil Gas Monitoring in the Vadose Zone,
(Revised 2001.
c.	 Calibration of Permeation Passive Samplers with Silicone Membranes Based on
Physiochemical Properties of the Analytes, Zabiegala Et al, 2003.
SAFETY
This procedure does not purport to address all of the safety problems associated with
its use. It is the responsibility of the user of this procedure to establish appropriate
safety and health practices. Appropriate PPE should be worn.
EQUIPMENT
a.	 Hand-Auger or drill rig
b.	 Electric or Cordless Hammer Drill
c.	 Narrow bottle brush and/or Wet dry
vacuum
d.	 WMS media including QA/QC units
e.	 Plastic sleeves
f.	 Foam Plugs
g.	 Suitable diameter and length pipe
and dowel
h.	 Foil
i.	 Thin rope, cord, fishing line or string
j.	 Chain of custody documentation
k.	 Cement for re-grouting core holes
after WMS retrieval
RECORDS
The following records need to be kept for
each sampling job:
•	 Time/Date of WMS deployment
and the sample location ID that
correlates to the WMS ID code.
•	 Samplers name
•	 Time/date of WMS retrieval
•	 Weather Conditions over the
exposure period
•	 Required Analysis
QUALITY CONTROL
Sample locations should be sampled in duplicate at a rate of one in ten unless
otherwise specified by the client. Trip Blanks should be included with each type
of media at a rate of one in ten. Laboratory analysis is conducted on each batch
of samplers as they are received to assess for VOC’s present from manufacturing
processes or transportation.
©SGSGroupManagementSA–2017–Allrightsreserved–SGSisaregisteredtrademarkofSGSGroupManagementSA
PROCEDURE
Prior to any excavation or penetration of the ground surface, the area must be cleared
of services by a suitably qualified services locator.
The exposure period for the WMS’s should be assessed by field screening with a PID.
For high soil gas PID readings, a shorter exposure period should be considered to avoid
saturation of the sample media.
1.	 Advance a borehole to the desired depth (generally a minimum of 1m) or just
below the base of a concrete slab for sub-slab installations.
2.	 Take a PID reading from the base of the open borehole by connecting a PID to a
1m length of Teflon tubing.
3.	 Record PID measurement on Chain of Custody and open the WMS from
packaging and connect to a pre-measured length of nylon cord or 2kg fishing line.
4.	 Lower the WMS to the desired depth within the borehole and secure at the
surface (Approximately 5cm from the base of the borehole). Document the time
and date of the installation on the Passive sampling COC (PF-AU-ENV-MIT-QU-
142-Passive Sampling COC)
5.	 Insert a foam plug into the base of the PVC pipe and then insert the pipe inside a
clean plastic sleeve.
6.	 Lower pipe with plug and plastic sleeve into the borehole to a depth just above
(10cm) the level of the WMS, use the length of dowel to poke the foam plug out of
the pipe and this will expand and push the plastic sleeve against the walls of the
borehole.
7.	 Cover the surface of the open borehole with aluminium foil and place a solid object
over the hole to prevent the WMS from being tampered with and to encourage
water to run away from the borehole rather than to drain into the hole. A thin ‘skin’
of concrete can also be used to prevent surface water entering the hole.
8.	 To retrieve the WMS’ simply take the protective cover from the surface of the
borehole and pull the plastic sleeve and plug from the borehole. Then remove the
WMS by raising to the surface with the cord or fishing line. Document the time
and date of the retrieval on the Passive sampling COC (PF-AU-ENV-MIT-QU-142-
Passive Sampling COC) and place the WMS back inside its unique coded glass
vial and ziplock bag. Transport to laboratory and indicate on the COC the required
analysis.
CONTACTS:
SGS ENVIRONMENT, HEALTH AND SAFETY
Adelaide, Brisbane, Cairns, Chinchilla, Mackay, Melbourne, Newcastle, Newman, Perth,
Shepparton, Sydney, Townsville, Traralgon
Phone: 1300 765 725
Email: au.enviro@sgs.com
Website: www.sgs.com.au

More Related Content

Similar to Waterloo Membrane Sampler Installation Methodology

Lab 12 measurement of sand contents present in drilling, mud by using and sa...
Lab 12  measurement of sand contents present in drilling, mud by using and sa...Lab 12  measurement of sand contents present in drilling, mud by using and sa...
Lab 12 measurement of sand contents present in drilling, mud by using and sa...Awais Qureshi
 
IMWA2013_Swanson_511
IMWA2013_Swanson_511IMWA2013_Swanson_511
IMWA2013_Swanson_511Eric Swanson
 
Presentation - Case Study on Site Investigation Plan at Chek.pptx
Presentation - Case Study on Site Investigation Plan at Chek.pptxPresentation - Case Study on Site Investigation Plan at Chek.pptx
Presentation - Case Study on Site Investigation Plan at Chek.pptxolaboughannam1
 
Presentation - Case Study on Site Investigation Plan at Chek.pptx
Presentation - Case Study on Site Investigation Plan at Chek.pptxPresentation - Case Study on Site Investigation Plan at Chek.pptx
Presentation - Case Study on Site Investigation Plan at Chek.pptxolaboughannam1
 
Westbay Nova Product Brochure 2015
Westbay Nova Product Brochure 2015Westbay Nova Product Brochure 2015
Westbay Nova Product Brochure 2015Nathan Lopez
 
Subsea field development
Subsea field developmentSubsea field development
Subsea field developmentHamid S
 
Transportation-Engg.-LABORATORY_MANUAL.pdf
Transportation-Engg.-LABORATORY_MANUAL.pdfTransportation-Engg.-LABORATORY_MANUAL.pdf
Transportation-Engg.-LABORATORY_MANUAL.pdfRESHMAFEGADE
 
OSEA J Grover 7 Dec 06
OSEA J Grover 7 Dec 06OSEA J Grover 7 Dec 06
OSEA J Grover 7 Dec 06John Grover
 
7) hydro test 3
7) hydro test 37) hydro test 3
7) hydro test 3ALISAB123
 
253651195 astm-c939
253651195 astm-c939253651195 astm-c939
253651195 astm-c939Socolap Pham
 
Why Concrete Coatings Fail
Why Concrete Coatings FailWhy Concrete Coatings Fail
Why Concrete Coatings FailWill Fowler
 
12 daniel c. meess - 4955983 - side loading vault system and method for the...
12   daniel c. meess - 4955983 - side loading vault system and method for the...12   daniel c. meess - 4955983 - side loading vault system and method for the...
12 daniel c. meess - 4955983 - side loading vault system and method for the...Mello_Patent_Registry
 
VG check list for OHE foundation
VG check list for OHE foundation VG check list for OHE foundation
VG check list for OHE foundation Varadharajalu Gopal
 

Similar to Waterloo Membrane Sampler Installation Methodology (20)

Lab 12 measurement of sand contents present in drilling, mud by using and sa...
Lab 12  measurement of sand contents present in drilling, mud by using and sa...Lab 12  measurement of sand contents present in drilling, mud by using and sa...
Lab 12 measurement of sand contents present in drilling, mud by using and sa...
 
Napesco Geotechnical Service Profile
Napesco Geotechnical Service ProfileNapesco Geotechnical Service Profile
Napesco Geotechnical Service Profile
 
IMWA2013_Swanson_511
IMWA2013_Swanson_511IMWA2013_Swanson_511
IMWA2013_Swanson_511
 
Well.Construction.pptx
Well.Construction.pptxWell.Construction.pptx
Well.Construction.pptx
 
Husam CV updated (1)
Husam CV updated (1)Husam CV updated (1)
Husam CV updated (1)
 
Presentation - Case Study on Site Investigation Plan at Chek.pptx
Presentation - Case Study on Site Investigation Plan at Chek.pptxPresentation - Case Study on Site Investigation Plan at Chek.pptx
Presentation - Case Study on Site Investigation Plan at Chek.pptx
 
Presentation - Case Study on Site Investigation Plan at Chek.pptx
Presentation - Case Study on Site Investigation Plan at Chek.pptxPresentation - Case Study on Site Investigation Plan at Chek.pptx
Presentation - Case Study on Site Investigation Plan at Chek.pptx
 
Westbay Nova Product Brochure 2015
Westbay Nova Product Brochure 2015Westbay Nova Product Brochure 2015
Westbay Nova Product Brochure 2015
 
L 37 final
L 37 finalL 37 final
L 37 final
 
Subsea field development
Subsea field developmentSubsea field development
Subsea field development
 
Transportation-Engg.-LABORATORY_MANUAL.pdf
Transportation-Engg.-LABORATORY_MANUAL.pdfTransportation-Engg.-LABORATORY_MANUAL.pdf
Transportation-Engg.-LABORATORY_MANUAL.pdf
 
OSEA J Grover 7 Dec 06
OSEA J Grover 7 Dec 06OSEA J Grover 7 Dec 06
OSEA J Grover 7 Dec 06
 
7) hydro test 3
7) hydro test 37) hydro test 3
7) hydro test 3
 
Vacuum process casting (v process)
Vacuum process casting (v process)Vacuum process casting (v process)
Vacuum process casting (v process)
 
253651195 astm-c939
253651195 astm-c939253651195 astm-c939
253651195 astm-c939
 
Why Concrete Coatings Fail
Why Concrete Coatings FailWhy Concrete Coatings Fail
Why Concrete Coatings Fail
 
12 daniel c. meess - 4955983 - side loading vault system and method for the...
12   daniel c. meess - 4955983 - side loading vault system and method for the...12   daniel c. meess - 4955983 - side loading vault system and method for the...
12 daniel c. meess - 4955983 - side loading vault system and method for the...
 
VG check list for OHE foundation
VG check list for OHE foundation VG check list for OHE foundation
VG check list for OHE foundation
 
Joint Resealing is a Vital Tool in the Concrete Pavement Preservation Toolbox
Joint Resealing is a Vital Tool in the Concrete Pavement Preservation ToolboxJoint Resealing is a Vital Tool in the Concrete Pavement Preservation Toolbox
Joint Resealing is a Vital Tool in the Concrete Pavement Preservation Toolbox
 
343312365 mt-ppt
343312365 mt-ppt343312365 mt-ppt
343312365 mt-ppt
 

Recently uploaded

Call Girls in Mayapuri Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Mayapuri Delhi 💯Call Us 🔝9953322196🔝 💯Escort.Call Girls in Mayapuri Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Mayapuri Delhi 💯Call Us 🔝9953322196🔝 💯Escort.aasikanpl
 
Biological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfBiological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfmuntazimhurra
 
GFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxGFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxAleenaTreesaSaji
 
Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)PraveenaKalaiselvan1
 
Biopesticide (2).pptx .This slides helps to know the different types of biop...
Biopesticide (2).pptx  .This slides helps to know the different types of biop...Biopesticide (2).pptx  .This slides helps to know the different types of biop...
Biopesticide (2).pptx .This slides helps to know the different types of biop...RohitNehra6
 
Natural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsNatural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsAArockiyaNisha
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...Sérgio Sacani
 
Animal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxAnimal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxUmerFayaz5
 
Physiochemical properties of nanomaterials and its nanotoxicity.pptx
Physiochemical properties of nanomaterials and its nanotoxicity.pptxPhysiochemical properties of nanomaterials and its nanotoxicity.pptx
Physiochemical properties of nanomaterials and its nanotoxicity.pptxAArockiyaNisha
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Sérgio Sacani
 
Orientation, design and principles of polyhouse
Orientation, design and principles of polyhouseOrientation, design and principles of polyhouse
Orientation, design and principles of polyhousejana861314
 
Is RISC-V ready for HPC workload? Maybe?
Is RISC-V ready for HPC workload? Maybe?Is RISC-V ready for HPC workload? Maybe?
Is RISC-V ready for HPC workload? Maybe?Patrick Diehl
 
Nanoparticles synthesis and characterization​ ​
Nanoparticles synthesis and characterization​  ​Nanoparticles synthesis and characterization​  ​
Nanoparticles synthesis and characterization​ ​kaibalyasahoo82800
 
Disentangling the origin of chemical differences using GHOST
Disentangling the origin of chemical differences using GHOSTDisentangling the origin of chemical differences using GHOST
Disentangling the origin of chemical differences using GHOSTSérgio Sacani
 
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |aasikanpl
 
Artificial Intelligence In Microbiology by Dr. Prince C P
Artificial Intelligence In Microbiology by Dr. Prince C PArtificial Intelligence In Microbiology by Dr. Prince C P
Artificial Intelligence In Microbiology by Dr. Prince C PPRINCE C P
 
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.aasikanpl
 
A relative description on Sonoporation.pdf
A relative description on Sonoporation.pdfA relative description on Sonoporation.pdf
A relative description on Sonoporation.pdfnehabiju2046
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRDelhi Call girls
 

Recently uploaded (20)

Call Girls in Mayapuri Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Mayapuri Delhi 💯Call Us 🔝9953322196🔝 💯Escort.Call Girls in Mayapuri Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Mayapuri Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
 
Biological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfBiological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdf
 
GFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxGFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptx
 
The Philosophy of Science
The Philosophy of ScienceThe Philosophy of Science
The Philosophy of Science
 
Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)
 
Biopesticide (2).pptx .This slides helps to know the different types of biop...
Biopesticide (2).pptx  .This slides helps to know the different types of biop...Biopesticide (2).pptx  .This slides helps to know the different types of biop...
Biopesticide (2).pptx .This slides helps to know the different types of biop...
 
Natural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsNatural Polymer Based Nanomaterials
Natural Polymer Based Nanomaterials
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
 
Animal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxAnimal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptx
 
Physiochemical properties of nanomaterials and its nanotoxicity.pptx
Physiochemical properties of nanomaterials and its nanotoxicity.pptxPhysiochemical properties of nanomaterials and its nanotoxicity.pptx
Physiochemical properties of nanomaterials and its nanotoxicity.pptx
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
 
Orientation, design and principles of polyhouse
Orientation, design and principles of polyhouseOrientation, design and principles of polyhouse
Orientation, design and principles of polyhouse
 
Is RISC-V ready for HPC workload? Maybe?
Is RISC-V ready for HPC workload? Maybe?Is RISC-V ready for HPC workload? Maybe?
Is RISC-V ready for HPC workload? Maybe?
 
Nanoparticles synthesis and characterization​ ​
Nanoparticles synthesis and characterization​  ​Nanoparticles synthesis and characterization​  ​
Nanoparticles synthesis and characterization​ ​
 
Disentangling the origin of chemical differences using GHOST
Disentangling the origin of chemical differences using GHOSTDisentangling the origin of chemical differences using GHOST
Disentangling the origin of chemical differences using GHOST
 
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
 
Artificial Intelligence In Microbiology by Dr. Prince C P
Artificial Intelligence In Microbiology by Dr. Prince C PArtificial Intelligence In Microbiology by Dr. Prince C P
Artificial Intelligence In Microbiology by Dr. Prince C P
 
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
 
A relative description on Sonoporation.pdf
A relative description on Sonoporation.pdfA relative description on Sonoporation.pdf
A relative description on Sonoporation.pdf
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
 

Waterloo Membrane Sampler Installation Methodology

  • 1. WATERLOO MEMBRANE SAMPLER (WMS) INSTALLATION METHODOLOGY SCOPE This method is intended for the passive sampling of Volatile Organic Compounds (VOCs) in ambient air and soil gas - using Waterloo membrane samplers (WMS’). This method is a guide on the installation process for WMS’ and does not purport to address all of the aspects of site assessment such as implementation of sampling pattern, sampling density/frequency, data interpretation, modelling, outside influences or technical issues. PRINCIPLE VOC’s in a gaseous phase move across a permeable membrane and sorb to absorbent medium within a glass vial. The membrane is made of poly-dimethyl siloxane (PDMS) which has known permeability values for a range of compounds. The movement of VOC’s across the PDMS membrane is controlled by the molecular mass of the individual organic compounds and the surface area of the membrane which is available for the VOC diffusion. REFERENCES a. ASTM D7758-11 Passive Soil Gas Sampling in the Vadose Zone for Source Identification, Spatial Variability Assessment, Monitoring, and Vapour Intrusion Evaluations, 2011. b. ASTM D5314 – 92), Standard Guide for Soil Gas Monitoring in the Vadose Zone, (Revised 2001. c. Calibration of Permeation Passive Samplers with Silicone Membranes Based on Physiochemical Properties of the Analytes, Zabiegala Et al, 2003. SAFETY This procedure does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this procedure to establish appropriate safety and health practices. Appropriate PPE should be worn. EQUIPMENT a. Hand-Auger or drill rig b. Electric or Cordless Hammer Drill c. Narrow bottle brush and/or Wet dry vacuum d. WMS media including QA/QC units e. Plastic sleeves f. Foam Plugs g. Suitable diameter and length pipe and dowel h. Foil i. Thin rope, cord, fishing line or string j. Chain of custody documentation k. Cement for re-grouting core holes after WMS retrieval RECORDS The following records need to be kept for each sampling job: • Time/Date of WMS deployment and the sample location ID that correlates to the WMS ID code. • Samplers name • Time/date of WMS retrieval • Weather Conditions over the exposure period • Required Analysis QUALITY CONTROL Sample locations should be sampled in duplicate at a rate of one in ten unless otherwise specified by the client. Trip Blanks should be included with each type of media at a rate of one in ten. Laboratory analysis is conducted on each batch of samplers as they are received to assess for VOC’s present from manufacturing processes or transportation.
  • 2. ©SGSGroupManagementSA–2017–Allrightsreserved–SGSisaregisteredtrademarkofSGSGroupManagementSA PROCEDURE Prior to any excavation or penetration of the ground surface, the area must be cleared of services by a suitably qualified services locator. The exposure period for the WMS’s should be assessed by field screening with a PID. For high soil gas PID readings, a shorter exposure period should be considered to avoid saturation of the sample media. 1. Advance a borehole to the desired depth (generally a minimum of 1m) or just below the base of a concrete slab for sub-slab installations. 2. Take a PID reading from the base of the open borehole by connecting a PID to a 1m length of Teflon tubing. 3. Record PID measurement on Chain of Custody and open the WMS from packaging and connect to a pre-measured length of nylon cord or 2kg fishing line. 4. Lower the WMS to the desired depth within the borehole and secure at the surface (Approximately 5cm from the base of the borehole). Document the time and date of the installation on the Passive sampling COC (PF-AU-ENV-MIT-QU- 142-Passive Sampling COC) 5. Insert a foam plug into the base of the PVC pipe and then insert the pipe inside a clean plastic sleeve. 6. Lower pipe with plug and plastic sleeve into the borehole to a depth just above (10cm) the level of the WMS, use the length of dowel to poke the foam plug out of the pipe and this will expand and push the plastic sleeve against the walls of the borehole. 7. Cover the surface of the open borehole with aluminium foil and place a solid object over the hole to prevent the WMS from being tampered with and to encourage water to run away from the borehole rather than to drain into the hole. A thin ‘skin’ of concrete can also be used to prevent surface water entering the hole. 8. To retrieve the WMS’ simply take the protective cover from the surface of the borehole and pull the plastic sleeve and plug from the borehole. Then remove the WMS by raising to the surface with the cord or fishing line. Document the time and date of the retrieval on the Passive sampling COC (PF-AU-ENV-MIT-QU-142- Passive Sampling COC) and place the WMS back inside its unique coded glass vial and ziplock bag. Transport to laboratory and indicate on the COC the required analysis. CONTACTS: SGS ENVIRONMENT, HEALTH AND SAFETY Adelaide, Brisbane, Cairns, Chinchilla, Mackay, Melbourne, Newcastle, Newman, Perth, Shepparton, Sydney, Townsville, Traralgon Phone: 1300 765 725 Email: au.enviro@sgs.com Website: www.sgs.com.au