It is adopts the theory of spectrophotometer. It used for plastic, printing, paint, ink, textile, dyeing and other industries for color management. It measure L*a*b, L*c*h and the sample △E and △Lab value
HSCD-750 adopts the geometric of D/11 lighting. It can be used for color matching for many industries and widely used in painting industry, textile industry, plastic industry, food industry, and other industries for quality control
DSCD-900 adopts the geometric of D/8, built-in full wavelength of LED, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, max ΔE*ab is 0.03
Electromagnetic Field Visualization System
EPS is a EMC/EMI debugging tool enabling designers to rapidly perform
pre-measurement, failure point identification, and improvement efficiency
confirmation in EMC/EMI countermeasure process of product design.
How does it work? The software detects locations of probes by color
discrimination through camera’s image sensors*, real time analysis measured signal frequency,
shows a heat map by overlapping electromagnetic field strength and real images of measured objects.
● A real-time diagnostic tool supports EMC/EMI debugging.
● Fast visualize EMC/EMI problems.
● Enables easy comparison of countermeasures before and after.
● Capable of measurement from entire products to single components.
● Factor-editor function provides correction of antenna characteristics, cable loss and pre-amplifier.
● User friendly compact design.
● Customer supplied spectrum and probes acceptable
https://www.n-denkei.com/singapore/inquiry/
HSCD-750 adopts the geometric of D/11 lighting. It can be used for color matching for many industries and widely used in painting industry, textile industry, plastic industry, food industry, and other industries for quality control
DSCD-900 adopts the geometric of D/8, built-in full wavelength of LED, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, max ΔE*ab is 0.03
Electromagnetic Field Visualization System
EPS is a EMC/EMI debugging tool enabling designers to rapidly perform
pre-measurement, failure point identification, and improvement efficiency
confirmation in EMC/EMI countermeasure process of product design.
How does it work? The software detects locations of probes by color
discrimination through camera’s image sensors*, real time analysis measured signal frequency,
shows a heat map by overlapping electromagnetic field strength and real images of measured objects.
● A real-time diagnostic tool supports EMC/EMI debugging.
● Fast visualize EMC/EMI problems.
● Enables easy comparison of countermeasures before and after.
● Capable of measurement from entire products to single components.
● Factor-editor function provides correction of antenna characteristics, cable loss and pre-amplifier.
● User friendly compact design.
● Customer supplied spectrum and probes acceptable
https://www.n-denkei.com/singapore/inquiry/
This presentation shows the basics of a volume hologram and its applications.The main focus of this presentation is optical computing using volume hologram. The optical computing schemes used in this presentation are Vundelught filter, joint Fourier transform correlator, and optical neural network.
We propose a flexible light field camera architecture that is at the convergence of optics, sensor electronics, and applied mathematics. Through the co-design of a sensor that comprises tailored, Angle Sensitive Pixels and advanced reconstruction algorithms, we show that—contrary to light field cameras today—our system can use the same measurements captured in a single sensor image to recover either a high-resolution 2D image, a low-resolution 4D light field using fast, linear processing, or a high-resolution light field using sparsity-constrained optimization.
Improvement of Weld Images using MATLAB –A Reviewinventy
Research Inventy provides an outlet for research findings and reviews in areas of Engineering, Computer Science found to be relevant for national and international development, Research Inventy is an open access, peer reviewed international journal with a primary objective to provide research and applications related to Engineering. In its publications, to stimulate new research ideas and foster practical application from the research findings. The journal publishes original research of such high quality as to attract contributions from the relevant local and international communities.
"Evaluation of the Hilbert Huang transformation of transient signals for brid...TRUSS ITN
Abstract: The assessment of bridge condition from vibration measurements has generally been determined via the monitoring of modal parameters determined though adaptations of the standard Fast Fourier Transform (FFT) or other stationary time-series based transformations. However, the non-stationary nature of measured vibration signals from damaged structures can limit the quality of frequency content information estimated by such methods. The Hilbert–Huang Transform’s (HHT) ability to decompose non-stationary measured vibration data into a time-frequency-energy representation allows signal variations to be identified sooner than other stationary-based transformations, thus potentially allowing early detection of damage. The present study uses data obtained from a progressive damage test conducted on a real bridge subjected to excitation from a double axle passing vehicle as a test subject. Decomposed vibration signals from the HHT and associated marginal spectrums are assessed to determine structural condition for various damage states and different locations along the bridge.
This presentation describes the use of a Shimadzu UV-2600 UV-Vis Spectrophotometer coupled to a standard optical microscope via an optical fiber relay system to evaluate small filter samples approximately 1–2 mm in width.
For more information, please go to ssi.shimadzu.com. Thanks for viewing.
This application note demonstrates an easy-to-fabricate holder that is suitable for many small samples. In addition, it shows the measurement of absolute total reflectance using this sample holder.
Desktop spectrophotometer DSCD-920 has the advantage of excellent inter-instrument agreement, high accuracy and good replicability. It could meet your requirement for both color quality control and color matching very easily.
It used in the surface gloss measurement for paint, plastic, metal, ceramics, building materials and so on. Our gloss meter conform to the DIN 67530, ISO 2813, ASTM D 523, JIS Z8741, BS 3900 Part D5, JJG696 standards
This presentation shows the basics of a volume hologram and its applications.The main focus of this presentation is optical computing using volume hologram. The optical computing schemes used in this presentation are Vundelught filter, joint Fourier transform correlator, and optical neural network.
We propose a flexible light field camera architecture that is at the convergence of optics, sensor electronics, and applied mathematics. Through the co-design of a sensor that comprises tailored, Angle Sensitive Pixels and advanced reconstruction algorithms, we show that—contrary to light field cameras today—our system can use the same measurements captured in a single sensor image to recover either a high-resolution 2D image, a low-resolution 4D light field using fast, linear processing, or a high-resolution light field using sparsity-constrained optimization.
Improvement of Weld Images using MATLAB –A Reviewinventy
Research Inventy provides an outlet for research findings and reviews in areas of Engineering, Computer Science found to be relevant for national and international development, Research Inventy is an open access, peer reviewed international journal with a primary objective to provide research and applications related to Engineering. In its publications, to stimulate new research ideas and foster practical application from the research findings. The journal publishes original research of such high quality as to attract contributions from the relevant local and international communities.
"Evaluation of the Hilbert Huang transformation of transient signals for brid...TRUSS ITN
Abstract: The assessment of bridge condition from vibration measurements has generally been determined via the monitoring of modal parameters determined though adaptations of the standard Fast Fourier Transform (FFT) or other stationary time-series based transformations. However, the non-stationary nature of measured vibration signals from damaged structures can limit the quality of frequency content information estimated by such methods. The Hilbert–Huang Transform’s (HHT) ability to decompose non-stationary measured vibration data into a time-frequency-energy representation allows signal variations to be identified sooner than other stationary-based transformations, thus potentially allowing early detection of damage. The present study uses data obtained from a progressive damage test conducted on a real bridge subjected to excitation from a double axle passing vehicle as a test subject. Decomposed vibration signals from the HHT and associated marginal spectrums are assessed to determine structural condition for various damage states and different locations along the bridge.
This presentation describes the use of a Shimadzu UV-2600 UV-Vis Spectrophotometer coupled to a standard optical microscope via an optical fiber relay system to evaluate small filter samples approximately 1–2 mm in width.
For more information, please go to ssi.shimadzu.com. Thanks for viewing.
This application note demonstrates an easy-to-fabricate holder that is suitable for many small samples. In addition, it shows the measurement of absolute total reflectance using this sample holder.
Desktop spectrophotometer DSCD-920 has the advantage of excellent inter-instrument agreement, high accuracy and good replicability. It could meet your requirement for both color quality control and color matching very easily.
It used in the surface gloss measurement for paint, plastic, metal, ceramics, building materials and so on. Our gloss meter conform to the DIN 67530, ISO 2813, ASTM D 523, JIS Z8741, BS 3900 Part D5, JJG696 standards
It used in different industries suchas plastic cement, printing, paint, weaving and dyeing. It measures the sample color data L*a*b*, L*c*h*, colordifference ΔE and ΔLab according to CIE colorspace.
Colorimeter is widely used in different industries such as plastic cement, printing, paint, weaving and dyeing. It measures the sample color data L*a*b*, L*c*h*, color difference ΔE and Δ Lab according to CIE color space.
Spectral colorimeter is the colorimeter which adopts the theory of spectroradiometer. It is widely used ofr plastic, printing, paint, ink, texitile, dyeing and other industries for color management.
WT5000 is the updated version of WT3000 with a super LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards IEC 60929, IEC 60969, IEC 61000-3-2, GB/T15144-2005, GB/T17263-1998 and so on.
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
It could be used for color matching for many industries and widely used in painting industry, textile industry, plastic industry, building material industry and other industries for quality control.
Rapid development of global economy brings serious environmental issues, which is becoming the focus of all around the world. The RoHS directive EU announced on Feb 13th of 2003 became effective on Jul 1st of 2007 for the purchase of restricting the pollution caused by the dispose of electronic and electrical products. Facing this environmental protection requirement, after years of hard work on R&D, Lisun has successfully developed EDX serious EDXRF spectrometer. EDXRF can detect and measure the hazardous substances restricted in RoHS directive quickly, precisely and nondestructively.
It is ccording to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters for 60 LED Drivers at one time in production line quick in 20s: Input Characteristics Test (AC), Output Characteristics Test (AC/DC) and harmonic
High precision-rotation-luminaire-goniospectroradiometer世满 江
LSG-1800BCCD goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source.
Introduction of Advanced PhotoDetector - Quantum Efficiency System(APD-QE)Enlitech
Introduction of Advanced PhotoDetector - Quantum Efficiency System(APD-QE)
Original link:https://enlitechnology.com/home/products/photo-detector-testing/apd-qe/
*About Enlitech
Enlitech was founded in March 2009.
The core technologies include artificial light source and spectrum analyzing technique.Enlitech’s four main product markets include image sensor testing solutions, advanced photoelectric detector testing systems, quantum efficiency test solutions, and various light simulators.
Our popular products are QER and SS-X solar simulator. If you are interested, please visit the official website to understand more!
https://enlitechnology.com/
It is according to IEC 60929, IEC 60969 and IEC61000-3-2. Up to 1MHz lrms can test every EB and has expanding analysis function for envelope wave. With big LCD can display the test results directly without PC
It is ccording to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters: Input Characteristics Test (AC/DC), Output Characteristics Test (AC/DC), Start Characteristics Test (DC) and Hormanic Test.
The chamber fully complies with the requirements of Standard GB/T16585-1996, GB14522-93, GB/T16422.3-97, ASTMG53 and etc., provides the best UV sunlight simulation, and is easy to use and operate.
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, German Angle Coder and Constant Temperature Class L Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
Full meet LM-79 Clause 9.3.1, GB, CIE & IEC Standards. Test intensity distribution curve in 3D & export IES files for DiaLux. It can test all kinds of luminaires which length up to dia=0.6m and max 20kg
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Japanese motor, Angle Coder and Constant Temperature Class A Detector to keep high accuracy. Both B-Beta & C-Gamma test for all luminaires up to 1.4m and 40kg
High Precision Goniophotometer for Automotive and Traffic Signal LampsLisun Group
It is a CIE A-α Goniophotometer and full meet GB, ECE, SAE, JIS, KS and FMVSS108. Test intensity distribution curve in 3D & export IES files for DiaLux. The test lamp can be max 35kg
Near Field Moving Detector GoniophotometerLisun Group
The near field moving detector goniophotometer is fully meet LM-79 and need very small dark room size. It tests intensity distribution curve in 3D & export IES files for DiaLux. It can test max size of luminaire up to Φ300mm(diameter)*550mm(height) and 20kg
Rotation Luminaire Goniophotometer (Big Size)1600BLisun Group
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor and Constant Temperature Detector to keep high accuracy. Test all luminaires up to 1.6m and 40kg
According to LM-79, GB, CIE & IEC Standards. Test intensity distribution curve in 3D & export IES files for DiaLux. It already combined 1m length dark room and used to test the lamps which diameter is less than 18cm
Rotation Luminaire GoniospectroradiometerLisun Group
Test Spatial CCT and intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor, Angle Coder and Constant Temperature Class A Detector to keep high accuracy. B-Beta & C-Gamma test for all lamps up to 1.6m and 40kg
Rotation Luminaire Goniophotometer (Big Size)Lisun Group
Test intensity distribution curve in 3D & export IES files for DiaLux. Applicated with Taiwan motor and Constant Temperature Detector to keep high accuracy. Test all luminaires up to 1.6m and 40kg
CCD Detector and spectrum range is 380~780nm. Test lux and all color parameters. The size is compact and applicated with 5inch big LCD Screen, with 4000mAH battery which can work over 20hours.
According to IESNA LM-80-2008, LM-82 and TM-21, it will record the lumen for L70, L50 and L30, the software is based on Arrhenius model to calculate the LED life
According to IEC61000-4-5, EN61000-4-12, ANSI C62.41.1/2-2002 and GB/T17626.5,12. Combined SG61000-5 Surge Generator and RWG61000-12 Ring Wave Generator, the system already built-in single phase CDN.
Includes EMI Receiver, Artificial Network, CDN23, Isolation Transformers, Attenuator and Coaxial Cable. Frequency is 9K~300MHZ, measure PK,QP and AV range from 20dBμV to 140dBμV, test tolerance is 2dB
IESNA-LM-79 (Electrical and Photometric Measurements of Solid-State Lighting Products) is a standard made by Illuminating Engineering Society of North America; this standard put forward the measurement standard and method, which clarify the test parameters, testing equipments, measurement rules and etc. The key point for this standard is to provide guidance for testing the luminous flux, color temperature, color rending index, power
Lms 9000 a新功能介绍:optical maintenance 和 electro-optical characteristics-enLisun Group
As we known that the quality of LED products depend on lumen, lumen efficiency temperature and CRI etc parameters, the general test device is application with spectroradiometer & integrating sphere system to measuring electrical, photometric and colorimetric parameters.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
CW RADAR, FMCW RADAR, FMCW ALTIMETER, AND THEIR PARAMETERSveerababupersonal22
It consists of cw radar and fmcw radar ,range measurement,if amplifier and fmcw altimeterThe CW radar operates using continuous wave transmission, while the FMCW radar employs frequency-modulated continuous wave technology. Range measurement is a crucial aspect of radar systems, providing information about the distance to a target. The IF amplifier plays a key role in signal processing, amplifying intermediate frequency signals for further analysis. The FMCW altimeter utilizes frequency-modulated continuous wave technology to accurately measure altitude above a reference point.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
We have compiled the most important slides from each speaker's presentation. This year’s compilation, available for free, captures the key insights and contributions shared during the DfMAy 2024 conference.
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Using recycled concrete aggregates (RCA) for pavements is crucial to achieving sustainability. Implementing RCA for new pavement can minimize carbon footprint, conserve natural resources, reduce harmful emissions, and lower life cycle costs. Compared to natural aggregate (NA), RCA pavement has fewer comprehensive studies and sustainability assessments.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
Spectral Colorimeter
1. Brochure
Chapter 1 Summarize
(大标题,居中小三加粗,尽量在新一页,用 Chapter 区分)
1. Operating instruction (一级标题,左对齐小四加粗)
According to the requirements of CIE, IESNA and the National’s standard, this
system is a multi-measurement mode spectrophotometer system which can realize
B-β, A-α and C-γ etc through rotating lamps and lanterns.
It test Spatial, light intensity distribution curves on any cross section (can be shown
under the rectangular coordinate system or polar coordinate system), spatial
iso-intensity curve. (正文,段首顶格左对齐 10 号,段落之间空行)
1.1 Explosive material (二级标题,左对齐五号加粗)
According to the requirements of CIE, IESNA and the National’s standard, this
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, KL, HK
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com
Lisun Electronics Inc. (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com
Lead in CFL & LED Test Instruments
Rev. 201609001
Spectral Colorimeter
(SCD Series)
2. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 1 -
Spectral Colorimeter
Basic Introduction
Spectral colorimeter is the colorimeter which adopts the theory of
spectrophotometer. It is widely used for plastic, printing, paint, ink, textile, dyeing
and other industries for color management. It could measure the target L*a*b,
L*c*h and the sample E and Lab value.
Product Model
SCD-380/SCD-385/SCD-386/SCD-388
Technical Features
Uses CLEDs light source – spectrally balanced LED light source
LED light source that has balanced intensity across visible spectrum avoids the
spectral deficiency in certain parts of the spectrum in common white LEDs, which
guarantees the speed and accuracy of the measurement results. This research has
been published in national leading optical journal Chinese Optics Letter.
ETC-Every Test calibration technology
Currently, most instruments use standard white boards for calibration. When white
board is damaged, the instrument’s accuracy or precision will no longer be
guaranteed. In this spectrophotometers, it uses innovative ETC (Every Test
Calibration); standard white board is included in the optical system, and therefore
has reliable accuracy and repeatability in every measurement.
3. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 2 -
Automatic gloss compensation technology
Different gloss or different instrument’s light source or observation conditions will
largely affect the color measurement. The automatic gloss compensation
technology guarantees the accuracy of color measurement data for surfaces of
different gloss. This research is published in international leading journal optic.
Innovative light splitting SCS optical engine
Adopt innovative single-grating-dual-light-paths light splitting system: SCS optical
engine, creates the best measurement repeatability for portable
spectrophotometers in the industry, and guaranteed accurate measurement of
surface color of materials.
4. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 3 -
Instrument Details
Technical Data
Type SCD-380 SCD-385 SCD-386 SCD-388
Illumination
DI/8(Diffused Illumination, 8 degree viewing)
(conform to CIE No.15、ISO 7724/1、ASTM E1164、DIN
5033 Teil7、 JIS Z8722 Condition c standard)
Size of integrating
sphere
Φ40mm, Avian diffused reflection surface coating
Illumination Light
source
CLED
Sensor array sensor
Wavelength 400-700nm
Spectrum Resolution 10nm
Measurement Time 2s
Measurement
Aperture
11mm,optional 4mm,6mm,15mm
Repeatability
Standard Deviation ∆E*ab 0.08(when a white calibration
plate is measured 30 x at 10-second intervals after
calibration)
Observe Angles 2° and 10°
Light Source A、C、D50、D65
A,C,D50,D55,D65,D75,F
1,F2,F3,F4,F5,F6,F7,F8,
F9,F10,F11,F12,DLF,TL8
3,TL84,NBF,U30,CWF ,
U35
Display Chromaticity value(L*a*b,L*C*h), delta E value,
5. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 4 -
Type SCD-380 SCD-385 SCD-386 SCD-388
pass/fail, color tendency, average, generate test report,
spectrum reflectance figure /data
With camera
to see the
measurement
area
With camera to see the
measurement area,
spectrum reflectance
figure /data, manual
input target data
Color Difference
Formula
∆E*ab, ∆E*CH
∆E*ab, ∆E*CH,∆E*uv,
∆E*cmc(2:1),∆E*cmc(1
:1),∆E*94,∆E*00
Color Space
CIE-L*a*b,
L*C*h,
reflectance
CIE-L*a*b,
L*C*h, XYZ,
Yxy,
reflectance
CIE-L*a*b, L*C*h,
L*u*v ,XYZ, Yxy,
reflectance
Other
WI(ASTM E313-10,ASTM
E313-73,CIE/ISO, AATCC, Hunter, Taube
Berger,Ganz,Stensby) YI(ASTM D1925,
ASTM E313-00,ASTM E313-73)
metameric index ,
staining fastness ,Color
fastness
Data Storage 20000samples
Light Source Lifetime 5 years, 1.5 million times
Other Function without
camera view, input color
swatches
camera view,
input color
swatches,
mobile phone
APP
Screen Panchromatic True Color Screen
Language Chinese and English
Interface USB2.0
USB2.0
Bluetooth
Operating
Temperature
5~45℃, relative humidity 80% or below( at 35°C ),no
condensation
Storage temperature
range
-25℃ to 55℃ , relative humidity 80% or below(at
35°C ),no condensation
Power
Rechargeable Lithium Battery 8.4V/2000mAh, adaptor
DC12V
Size 77×86×210mm
Weight About 550g
Standard
Accessories
adapter, operating manual, color management
software, drive software, electronic manual, color
management guide, USB cable, black/white calibration
6. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 5 -
Type SCD-380 SCD-385 SCD-386 SCD-388
tube, protective cover, portable bag, electronic color
charts
Optional Micro Printer
Color Matching
System
Not matched
UV Light Source without
Application
Plastic Paint Print Food Textile Car